3826_FIXTURE_SPECIFICATIONS.pdf

PDF 8 MB Posted

Attached to
Splashpad Renovation and Improvement
Solicitation number
38-26
Issued by
Florida

About this file

This fixture specifications document supports a Splashpad Renovation and Improvement project in Florida. The specifications detail the technical requirements and standards for all fixtures to be installed as part of the splashpad renovation. The document establishes performance criteria, material standards, and installation requirements that contractors must follow to ensure compliance with the construction plans. Fixtures specified include water play equipment, safety components, drainage systems, and related amenities necessary for the splashpad facility. These specifications serve as binding requirements that all bidding contractors must meet in their proposals and final construction work.

The fixture specifications establish minimum quality standards and operational performance metrics that all materials and equipment must satisfy throughout the project. The document provides detailed technical descriptions, reference standards, and testing requirements to ensure the splashpad renovation meets safety codes and functional performance standards. Contractors are required to verify all fixture specifications against the complete construction documents and plans before submitting proposals, and any discrepancies or conflicts must be identified during the bidding process. The specifications ensure consistency between all bid proposals and establish clear expectations for the final completed project.

View the file

Other files

File Type Posted
3826_PUMP_SPECIFICATIONS.pdf PDF
3826_STAMPED_PLAN_SET_91626.pdf PDF
3826_COMPILED_SPECIFICATIONS.pdf PDF
RFP_3826__Splashpad_Renovation_and_Improvement.pdf PDF
Exhibit_I_Bid_Price_Sheet.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A

B B

PRODUCT NAME

PRODUCT PART # REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Creature Feature Egg Hatcher\CFEG-002\CFEG-002-ZCS.idw

HEAD

RECIRCULATED WATER

4'

No

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

2"

Yes

Yes

Yes

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2016 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW 8.4 GPM

5.4 GPM TO 11.5 GPM

CFEG-002

CREATURE FEATURE BABY EGG HATCHER

1'-2 5/8"

[37.2 cm]

1'-3 3/4"

[40.0 cm]

WATER OUTLET

TYP. OF 5

2" SUPPLY LINE OR

PER LOCAL CODE.

AREA OF INFLUENCE:

6' DIAMETER

VARIES WITH FLOW

AGE AND WEIGHT GUIDELINES

2-6 7-12 13+ WEIGHT LIMIT

X X 150 LBS

1'-3 1/4"

[38.7 cm]

BASE TO BE SECURED

BY (3) Ø3/8" S.S.

CONCRETE ANCHORS

WARNING:

DO NOT EXCEED THE MAXIMUM FLOW RATE OF

11.5 GPM.

NOTE:

#1 CONCRETE MUST BE LEVEL 2'-0" IN DIAMETER

CENTERED ON THE WATER SUPPLY.

#2 HEAD REQUIRED MEASURED FROM BASE OF

FEATURE.

#3 SUPPLY LINE TO BE STUBBED UP THROUGH

THE CONCRETE AND FIELD CUT TO CONNECT

THE WATER FEATURE ACCORDINGLY.

#4 CONCRETE TO BE 6" MINIMUM

THICKNESS OR PER LOCAL CODE.

#5 FLOW RATES CALCULATED BASED ON THE

FOLLOWING VELOCITIES:

MINIMUM: 7 FPS

INTENDED: 11 FPS

MAXIMUM: 15 FPS

#6 FEATURE COMPONENTS TO BE FIELD

ADJUSTED/MODIFIED AS NEEDED BASED ON

FIELD CONDITIONS.

A A

B B

PRODUCT NAME

PRODUCT PART #

DSTX-001

REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Creature Feature Toby the T-Rex\DSTX-001\DSTX-001-ZCS.idw

CREATURE FEATURE TOBY T-REX

HEAD

RECIRCULATED WATER

7'

No

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

2"

Yes

Yes

Yes

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2014 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW 16.8 GPM

10.7 GPM TO 23.0 GPM

2" SUPPLY LINE OR

PER LOCAL CODE.

AREA OF INFLUENCE:

8' L X 8' W

VARIES WITH FLOW

5'-1"

[154.8 cm]

AGE AND WEIGHT GUIDELINES

2-6 7-12 13+ WEIGHT LIMIT

X X 150 LBS

BASE TO BE SECURED

BY (4) Ø3/8" S.S.

CONCRETE ANCHORS

5'-9 3/4"

[177.2 cm]

4'-4 1/2"

[133.3 cm]

WATER OUTLET

TYP. OF 6

WATER OUTLET

TYP. OF 4

WARNING:

DO NOT EXCEED THE MAXIMUM FLOW RATE OF

23.0 GPM.

NOTE:

#1 CONCRETE MUST BE LEVEL 2'-0" IN DIAMETER

CENTERED ON THE WATER SUPPLY.

#2 HEAD REQUIRED MEASURED FROM BASE OF

FEATURE.

#3 SUPPLY LINE TO BE STUBBED UP THROUGH

THE CONCRETE AND FIELD CUT TO CONNECT

THE WATER FEATURE ACCORDINGLY.

#4 CONCRETE TO BE 6" MINIMUM

THICKNESS OR PER LOCAL CODE.

#5 FLOW RATES CALCULATED BASED ON THE

FOLLOWING VELOCITIES:

MINIMUM: 7 FPS

INTENDED: 11 FPS

MAXIMUM: 15 FPS

#6 FEATURE COMPONENTS TO BE FIELD

ADJUSTED/MODIFIED AS NEEDED BASED ON

DETAIL A

A

A A

B B

PRODUCT NAME

PRODUCT PART #

ELLS-003-SS

REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Spinner Elevated Lasso\ELLS-003-SS\ELLS-003-SS-ZCS.idw

ELEVATED SPINNING LASSO W/ 2 PTERODACTYL TOPPERS, STAINLESS

HEAD

RECIRCULATED WATER

15'

No

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

2"

Yes

Yes

Yes

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2014 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW 18.5 GPM

11.8 GPM TO 25.3 GPM

2" SUPPLY LINE OR

PER LOCAL CODE.

AREA OF INFLUENCE:

10' DIAMETER

VARIES WITH FLOW

11'-5 1/4"

[348.6 cm]

AGE AND WEIGHT GUIDELINES

2-6 7-12 13+ WEIGHT LIMIT

X X X 300 LBS

n3'-3 1/2"

[n100.3 cm]

BASE TO BE SECURED

BY (4) Ø3/4" S.S.

EXPANSION ANCHORS

ATTACHED SKIRTING

n8 5/8"

[n21.9 cm]

3'- 3/4"

[93.3 cm]

WATER OUTLET

TYP. OF 11

GASKET

WARNING:

DO NOT EXCEED THE MAXIMUM FLOW RATE OF

25.3 GPM.

NOTE:

#1 CONCRETE MUST BE LEVEL 2'-0" IN DIAMETER

CENTERED ON THE WATER SUPPLY.

#2 HEAD REQUIRED MEASURED FROM BASE OF

FEATURE.

#3 SUPPLY LINE TO BE STUBBED UP THROUGH

THE CONCRETE AND FIELD CUT TO CONNECT

THE WATER FEATURE ACCORDINGLY.

#4 CONCRETE TO BE 6" MINIMUM

THICKNESS OR PER LOCAL CODE.

#5 FLOW RATES CALCULATED BASED ON THE

FOLLOWING VELOCITIES:

MINIMUM: 7 FPS

INTENDED: 11 FPS

MAXIMUM: 15 FPS

#6 FEATURE COMPONENTS TO BE FIELD

ADJUSTED/MODIFIED AS NEEDED BASED ON

FIELD CONDITIONS.

ATTACH A COPPER WIRE

FROM THE BONDING GRID

TO THE BONDING LUG

A A

B B

PRODUCT NAME

PRODUCT PART #

FOPT-001

REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Feature Ornament Parrot\FOPT-001\FOPT-001-ZCS.idw

FEATURE ORNAMENT PARROT TOPPER

HEAD

RECIRCULATED WATER

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2014 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW GPM

GPM TO GPM

22 3/4

8 5/8

MOUNTING

A A

B B

PRODUCT NAME

PRODUCT PART #

RNTR-016

REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Rain Tree\RNTR-016\RNTR-016-ZCS.idw

RAIN TREE, 3 BANANA BKT, TALL, DINO THEME

HEAD

RECIRCULATED WATER

35'

No

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

3"

Yes

Yes

Yes

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2014 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW 81.7 GPM

51.9 GPM TO 111.4 GPM

3" SUPPLY LINE OR

PER LOCAL CODE.

AREA OF INFLUENCE:

20' DIAMETER

VARIES WITH FLOW

AGE AND WEIGHT GUIDELINES

2-6 7-12 13+ WEIGHT LIMIT

X X X 300 LBS

WARNING:

DO NOT EXCEED THE MAXIMUM FLOW RATE OF

111.4 GPM.

NOTE:

#1 CONCRETE MUST BE LEVEL 2'-0" IN DIAMETER

CENTERED ON THE WATER SUPPLY.

#2 HEAD REQUIRED MEASURED FROM BASE OF

FEATURE.

#3 SUPPLY LINE TO BE STUBBED UP THROUGH

THE CONCRETE AND FIELD CUT TO CONNECT

THE WATER FEATURE ACCORDINGLY.

#4 CONCRETE TO BE 6" MINIMUM

THICKNESS OR PER LOCAL CODE.

#5 ALL MOUNTING POINTS MUST BE WITHIN

+- 1/4" OF THE SAME ELEVATION UNLESS

OTHERWISE NOTED.

#6 FLOW RATES CALCULATED BASED ON THE

FOLLOWING VELOCITIES:

MINIMUM: 7 FPS

INTENDED: 11 FPS

MAXIMUM: 15 FPS

#7 FEATURE COMPONENTS TO BE FIELD

ADJUSTED/MODIFIED AS NEEDED BASED ON

FIELD CONDITIONS.

17'-5 1/4"

[531.6 cm]

10'-10 5/8"

[331.8 cm]

8'-2 5/8"

[250.4 cm]

WATER OUTLET

TYP. OF 12

WATER OUTLET

TYP. OF 2

BASE TO BE SECURED

BY Ø1/2" S.S.

EXPANSION ANCHORS

WATER OUTLET

TYP. OF 3

13920 Cypress Lane Grandview, MO 64030 | 800-323-2359 | sternwilliams.com

MODEL 6200 OUTDOOR BODY AND FOOT SHOWERS

FEATURES

The deep, rich Sky Blue color and scratch resistant finish make these showers an excellent choice for resorts, beach front areas, sand volleyball courts and recreational areas.

Models include two chrome plated brass shower heads. Vandal proof design with no exposed fasteners, non removable spray heads with adjustable spray patterns using a 1/8” allen wrench inserted through spray head orifice.

6200_Spec-D

-GR-BL -OR -RD -YL -SV -WH -BZ -SD -BK -CC

• All steel heavy-duty construction with welded and ground joints for a clean and tidy appearance

•All exposed parts are recessed in welded steel plates
•Stainless Steel (-SS) bodies available for harsh coastal environments
•Vandal resistant access plates for security and simple future maintenance.
•Optional mounting plates available for installation assistance
•SMP-6: Surface mounting plate
•IBA-6: In-ground mounting plate

• Recessed push button requires less than 5 lbs of force and is manufactured from chrome plated brass for reliability and long wear life

•Stainless steel supply fittings connected to reinforced tubing
•Water pressure range of 30-80 PSI
•Simple flow adjustment without dismantling of the fountain with a water flow

of 2.5 GPM

• Timer controlled shower heads are made from heavy duty materials with a preset running time of 60 seconds that can be adjusted from 0 to 60 seconds

•Shower head spray pattern is adjustable from stream to mist
•½”reinforced vinyl tubing with ½”IPS hook-up and stainless steel fittings
•½” inlet stop valve for simple future maintenance
•Standard Sky Blue finish with optional colors available
•Custom color orders are non-cancellable and non-returnable

ORDERING OPTIONS

6200- 6200-MWL-

SS: Stainless steel finish

32: RCP Hose Bibb with VB

32-LK: RCP Hose Bibb with VB and Key

40: Commemorative Plaque

85: Valve Box

SMP-6: Surface Mounting Plate

Part Number

Optional Optional

DIMENSIONS

All dimensions subject to manufacturing variance of plus or minus 1/4″ (6 mm)

80″H x 6-5/8″ Dia. - Surface mount 80″H x 6-5/8″ Dia. - Wall mount

6200-MWL

Furnish and install the Stern-Williams Outdoor Body and Foot Shower (specify model color). Shower towers shall be carbon steel or 304 stainless steel and a powder coated finish. Shower heads shall be chrome plated brass with a water pressure range of 30-80 PSI. Shower heads shall include adjustable spray patterns and adjustable timing of 0-60 seconds. Shower towers shall provide simple flow adjustment without requiring dismantling of shower with a water flow of 2.5 GPM. Welded anchor base shall be 1/2” thick. Push buttons shall require less than 5 lbs of force. Shower towers shall be installed per manufacturers recommendations and instructions. Made in the USA.

SPEC

SS: Stainless Steel Body Upgrade

31: Chrome Plated Jug Filler

32: RCP Hose Bibb with VB

32-LK: RCP Hose Bibb with VB and Key

32-SC: Self Closing Hose Bibb with VB

32-VP: Recessed Vandal Proof Valve

35: Recessed Compression Type

35-VP: Recessed Hose Bibb with Lock

38: Shutdown/Drain Valve

40: Commemorative Plaque

82: Handwash Station

85: Valve Box

87: Metal Valve Box

100: Solar Light

SMP-6: Surface Mounting Plate

IBA-6: In-Ground Bury Adapter x x

A A

B B

PRODUCT NAME

PRODUCT PART # REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Volcano\VOLC-007\VOLC-007-ZCS.idw

HEAD

RECIRCULATED WATER

8'

No

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

2"

Yes

Yes

Yes

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2017 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW 3.8 GPM

2.4 GPM TO 5.2 GPM

VOLC-007

VOLCANO 5' W/ DIRECTIONAL SPRAY

2" SUPPLY LINE OR

PER LOCAL CODE.

AREA OF INFLUENCE:

6' DIAMETER

VARIES WITH FLOW

5'-2 1/2"

[158.8 cm]

5'- 5/8"

[154.0 cm]

5'- 1/2"

[153.7 cm]

BASE TO BE SECURED

BY (4) Ø1/2" S.S.

EXPANSION ANCHORS

AGE AND WEIGHT GUIDELINES

2-6 7-12 13+ WEIGHT LIMIT

X X 150 LBS

WARNING:

DO NOT EXCEED THE MAXIMUM FLOW RATE OF

5.2 GPM.

NOTE:

#1 CONCRETE MUST BE LEVEL 2'-0" IN DIAMETER

CENTERED ON THE WATER SUPPLY.

#2 HEAD REQUIRED MEASURED FROM BASE OF

FEATURE.

#3 SUPPLY LINE TO BE STUBBED UP THROUGH

THE CONCRETE AND FIELD CUT TO CONNECT

THE WATER FEATURE ACCORDINGLY.

#4 CONCRETE TO BE 6" MINIMUM

THICKNESS OR PER LOCAL CODE.

#5 FLOW RATES CALCULATED BASED ON THE

FOLLOWING VELOCITIES:

MINIMUM: 7 FPS

INTENDED: 11 FPS

MAXIMUM: 15 FPS

#6 FEATURE COMPONENTS TO BE FIELD

ADJUSTED/MODIFIED AS NEEDED BASED ON

WATER OUTLET

A A

B B

PRODUCT NAME

PRODUCT PART # REV

SHEET 1 OF 1

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF RAIN DROP PRODUCTS LLC. ANY

REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF RAIN DROP PRODUCTS LLC

IS PROHIBITED.

C:\Vault workspace\Designs\Above Ground Features\Water Fun Cannon\WFCN-040-OM\WFCN-040-OM-ZCS.idw

HEAD

RECIRCULATED WATER

7'

Yes

WWW.RAIN-DROP.COM

T-419.207.1229 F-419.207.8902

MINIMUM SUPPLY LINE SIZE

SALT WATER

POTABLE WATER

OMNIPOD COMPATIBLE

2"

Yes

Yes

Yes

NUMBER OF PEOPLE TO INSTALL

MANHOURS TO INSTALL

©2016 Rain Drop Products, LLC.

All rights reserved

GPM OPERATION RANGE

INTENDED FLOW 5.7 GPM

3.6 GPM TO 7.8 GPM

WFCN-040-OM

WATER FUN CANNON TRICERATOPS, OMNI

4'-5"

[134.5 cm]

1'-9 3/8"

[54.3 cm]

1'-7 1/2"

[49.5 cm]

AREA OF INFLUENCE:

6' DIAMETER

VARIES WITH FLOW

WATER OUTLET

ATTACHED

SKIRTING

OMNIPOD

2" SUPPLY LINE OR

PER LOCAL CODE.

AGE AND WEIGHT GUIDELINES

2-6 7-12 13+ WEIGHT LIMIT

X X X 300 LBS

WARNING:

DO NOT EXCEED THE MAXIMUM FLOW RATE OF

7.8 GPM.

NOTE:

#1 CONCRETE MUST BE LEVEL 2'-0" IN DIAMETER

CENTERED ON THE WATER SUPPLY.

#2 HEAD REQUIRED MEASURED FROM BASE OF

FEATURE.

#3 SUPPLY LINE TO BE SOLVENT WELDED TO

OMNIPOD FEATURE RECEIVER.

#4 CONCRETE TO BE 6" MINIMUM

THICKNESS OR PER LOCAL CODE.

#5 FLOW RATES CALCULATED BASED ON THE

FOLLOWING VELOCITIES:

MINIMUM: 7 FPS

INTENDED: 11 FPS

MAXIMUM: 15 FPS

n6 5/8"

[n16.8 cm]

BASE TO BE SECURED

BY (4) Ø1/2" S.S.

EXPANSION ANCHORS

Bench Spec - b32c_6_8_rec 2
CFEG-002-ZCS
DSTX-001-ZCS
ELLS-003-SS-ZCS
FOPT-001-ZCS
RNTR-016-ZCS
Shower Spec - 6200_Spec-D
VOLC-007-ZCS
WFCN-040-OM-ZCS

File details come from the government source that posted it. Updated .