36E77619R0036-0003007.pdf
PDF 18 MB Posted
- Solicitation number
- 36E77619R0036
About this file
36E77619R0036 0003 YKKAP-Blast Products.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77619C0059-000.docx | DOCX document | |
| 36E77619R0036-0005001.pdf | ||
| 36E77619R0036-0005000.docx | DOCX document | |
| 36E77619R0036-0004001.pdf | ||
| 36E77619R0036-0004000.docx | DOCX document | |
| 36E77619R0036-0003001.pdf | ||
| 36E77619R0036-0003003.pdf | ||
| 36E77619R0036-0003004.pdf | ||
| 36E77619R0036-0003005.pdf | ||
| 36E77619R0036-0003006.pdf | ||
| 36E77619R0036-0003002.pdf | ||
| 36E77619R0036-0003000.docx | DOCX document | |
| 36E77619R0036-0002000.docx | DOCX document | |
| 36E77619R0036-0001000.docx | DOCX document | |
| 36E77619R0036-0001001.pdf | ||
| 36E77619R0036-004.pdf | ||
| 36E77619R0036-007.pdf | ||
| 36E77619R0036-008.pdf | ||
| 36E77619R0036-005.pdf | ||
| 36E77619R0036-002.pdf | ||
| 36E77619R0036-009.docx | DOCX document | |
| 36E77619R0036-006.pdf | ||
| 36E77619R0036-010.pdf | ||
| 36E77619R0036-003.pdf | ||
| 36E77619R0036-001.docx | DOCX document | |
| 36E77619R0036-000.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
This submittal package is to assist in the specification and selection of YKK AP products. Basic product descriptions and technical data are included. For further information or technical assistance, please contact your local YKK AP representative.
Submittal Package
Entrances | Storefronts | Window Walls | Curtain Walls | Balcony Doors | Sun Controls visit our website at ykkap.com
Submitted to:
YKK AP America’s manufacturing facility located in Dublin, Georgia and has achieved ISO 14001 certification as a means to measure and continually improve environmental performance.
Project:
Submitted by:
YKK AP products Included:
VA Outpatient Mental Health Building Sioux Falls
Heartland Glass Company Timothy Bronsteader
June 27, 2019
YHC 300 OG, YFW 400 TUH
YHC 300 OG
YHC 300 OG
Impact Resistant and Blast Mitigating, Outside Glazed Curtain Wall
Protection for Every Application
Product Options & Features
The YHC 300 OG is a high performance curtain wall system designed and tested to provide innovative impact and blast solutions for a wide range of applications and design pressures from 45 PSF all the way to 130 PSF. The 3” face dimension ensures recommended glass clearances are maintained. Dry glazing options (for all design pressure ranges) slash installation time for quicker building dry-in.
This data sheet also shows the PSF differences for each variation of the YHC 300 OG.
n Fully tested to ASTM 1886 / 1996 and TAS 201-203 standards n Florida Product Approvals for large and small missile including HVHZ and Level E Protection n Mullion options provide the most cost effective solutions across all pressures and designs n 15/16” glass bites maintain GANA guidelines of 1/4” clearance to reduce glass breakage
| n | Designed for single and multispan applications |
| n | Achieve 17’ single spans at 90 PSF |
| n | Accommodates monolithic and insulating glass |
| n | Shallow mullion option available |
https://www.ykkap.com/commercial/performance-product-lines/protek/ https://www.ykkap.com/commercial/performance-product-lines/protek/ https://www.ykkap.com/commercial https://www.ykkap.com/commercial/product/curtain-walls/yhc-300-og/
©2018 YKK AP America Inc. is a subsidiary of YKK Corporation of America.
270 Riverside Pkwy, Suite 100, Austell, GA 30168 Tel: 678-838-6000
SYSTEM SPECIFICATIONS YHC 300 OG
04-5014-03
System Sightline
Base Depth
Glazing & Config Glass Air
Infiltration Water
Infiltration Thermal
Performance Acoustical
Performance
3” 7-1/16” Outside
Front Set
9/16” Monolithic or 1-5/16” IGU with Low-E (C.O.G.
U-factor: 0.29)
0.06 CFM/FT²
(1.10 m³/h·m²)
Static: 20 PSF (958 Pa) Dynamic: 20 PSF (958 Pa)
U-factor: 0.42 BTU/HR•FT²•ºF* CRF: Minimum of 72 on frame**
Lam STC: 37 Lam OITC: 32
Testing Standards ASTM E 283 ASTM E 331 & AAMA 501 * NFRC 102 & ** AAMA 1503 ASTM E 90 & 1425
Product Approvals Missile Level A, D, E, Wind Zone 3 & HVHZ, ICC Florida Building Code, TDI Compliant
Available Finishes Factory Anodized (AAMA 612) and Organic Paints (AAMA 2605)
Additional information including CAD details, CSI specifications, Test Reports and Installation instructions are available online at:
www.ykkap.com/commercial/product/curtain-walls/yhc-300-og/ n ICC Compliant and FBC Statewide approvals – HVHZ (High Velocity Hurricane Zone) n Large Missile Level E – Essential Facilities n Large Missile Level D & Small Missile Level A n “Low Hazard” per ASTM F 1642 Test @ 6 psi / 41 psi–ms Dry Glazing option shown. Visit www.ykkap.com for glazing options and CSI Specs by performance and glazing type.
HURRICANE & BLAST PROTECTION
Low Pressure
45-55 PSF
Standard Pressure
65-90 PSF
High Pressure
90-130 PSF
Vertical
Vertical
Horizontal
Horizontal
7-11/16” [195.6mm]
10-1/2” [266.7mm]
5-5/8” [142.9mm]
Horizontal
Optional Steel Reinforcement
Optional Steel Reinforcement
Optional Shallow
45-55 PSF OPTION
65-90 PSF OPTION
90-130 PSF OPTION
3” [76.2mm]
Vertical
1/4” Minimum Glass Clearance
Typical
Vertical
Vertical
Horizontal
Horizontal
7-11/16” [195.6mm]
10-1/2” [266.7mm]
5-5/8” [142.9mm]
Horizontal
Optional Steel Reinforcement
Optional Steel Reinforcement
Optional Shallow
45-55 PSF OPTION
65-90 PSF OPTION
90-130 PSF OPTION
3” [76.2mm]
Vertical
1/4” Minimum Glass Clearance
Typical https://www.ykkap.com/commercial/product/curtain-walls/yhc-300-og/
YHC 300 OG Curtain Wall System
Page-3Effective Date: August 16, 2018 | 04-1009-07
WEEP
HOLE
RETAINER
BOLT
HORIZONTAL
SHEAR BLOCK
MULLIONPRESSURE PLATE
GASKET
JOINT
PLUG
PRESSURE
PLATE
FACE
COVER
YHC 300 OG OUTSIDE GLAZED
HURRICANE RESISTANT CURTAIN WALL SYSTEM
Page-4 04-1009-07 | Effective Date: August 16, 2018
SILICONE
COVER
SPLICE
BOND
BREAKER
TAPE &
SILICONE
MULLION
SPLICE
SLEEVE
BOND BREAKER
TAPE & SILICONE
TYPICAL SPLICE CONDITION
Page-5Effective Date: August 16, 2018 | 04-1009-07
MULLION END
“J” ANCHOR
(Use at Sill Only)
MULLION END “J” ANCHOR
Page-6 04-1009-07 | Effective Date: August 16, 2018
MULLION END
“T” ANCHOR
(Use at Head or Sill)
E1-3006
ANCHOR
SLEEVE
MULLION END “T” ANCHOR
Page-7Effective Date: August 16, 2018 | 04-1009-07
FOR DESIGN PRESSURES OF 45-55 PSF
OPTIONAL 1” GLAZING
(For Non-Impact Conditions)
E2-0380
MULLION
3, 3A
2B
2A
2C
5-
/1 6”
[1
.5 m m
SECTION 1
SECTION 2 SECTION 2A
HEAD w/ “T” or “F” Anchor
SECTION 3
SECTION 4
SILL w/ “T” or “F” Anchor
SECTION 3A
SECTION 5
SILL w/ “T” or “F” Anchor
SECTION 2B
HORIZONTAL (One-Piece)
Mono. Gl. over Insul. Gl. Mono. Gl. over Insul. Gl.
Insul. Gl. over Insul. Gl.
Insul. Gl. over Insul. Gl.
SECTION 2C
HORIZONTAL (Two-Piece)
E 9-
E 9-
E 9-
E 9-
E 9-
E 9-
E 9-
E9-8169
E9-8169
E9-8169E9-8169
E9-3126 E9-3126
E9-8169
YHC 300 OG Shallow Framing Members for Insulating Glazing
Page-8 04-1009-07 | Effective Date: August 16, 2018
FOR DESIGN PRESSURES OF 45-55 PSF
YHC 300 OG Shallow Framing Members for Insulating Glazing
E9-8169
TYPICAL WINDLOAD ANCHOR
E9-3126
SCALE: 1/4 SIZE
0 3 6
SECTION 6
SECTION 7
90° OUTSIDE CORNER
SINGLE GLAZING
E 9-
E9-3161
E9-3126
E 9-
Page-9Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Single Glazing
FOR DESIGN PRESSURES OF 45-55 PSF
SCALE: 1/4 SIZE
0 3 6
SECTION 11
JAMB SECTION 12
MULLION
8A
11 12
10A10
22A
9A 12A
SECTION 8
HEAD w/ “F” Anchor
SECTION 8A
HEAD w/ “T” Anchor
SECTION 9A
HORIZONTAL (Two-Piece)
SECTION 10A
SILL w/ “T” Anchor
SECTION 9
HORIZONTAL (One Piece)
SECTION 10
SILL w/ “J” Anchor
E9-8167
E9-3107
E9-3161
E 9-
3” [76.2mm]
6-
/1 6”
[1
.4 m m
AS-3173
9B
E 9-
E9-8169
E9-3107 E9-3107
SECTION 9C
OPTIONAL HORIZONTAL
(Two-Piece)
E9-3161
9C
OPTIONAL 1/4” GLAZING
(For Non-Impact Conditions)
SECTION 12A
MULLION @ SPLICE
AS-3173AS-3173
AS-3179
E 9-
E 9-
E9-3162AS-3179
E 9-
E9-3162
E 9-
E 9-
E9-3162 E
9-
E9-3162
E9-3105
E9-3162
SECTION 9B
OPTIONAL HORIZONTAL
(One Piece)
E9-3106
E2-0380
Page-10 04-1009-07 | Effective Date: August 16, 2018
FOR DESIGN PRESSURES OF 45-55 PSF
YHC 300 OG Framing Members for Single Glazing
E9-8167 E9-3106
TYPICAL DEADLOAD ANCHOR
TYPICAL WINDLOAD ANCHOR
SECTION 13
SECTION 14
SCALE: 1/4 SIZE
0 3 6
E9-3107
E9-3107
E9-8167 E9-3106
Page-11Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Insulating Glazing
FOR DESIGN PRESSURES OF 45-55 PSF
OPTIONAL 1” GLAZING
(For Non-Impact Conditions)
E2-0380
SECTION 15 SECTION 15A
23A 18A
17A
15A
16A16
SECTION 16 SECTION 16A
SECTION 17
SECTION 18
SECTION 19
SECTION 19A
SECTION 17A
MULLION
MULLION
2 2A 19A
Page-12 04-1009-07 | Effective Date: August 16, 2018
FOR DESIGN PRESSURES OF 45-55 PSF
E9-8169 E9-3102
TYPICAL DEADLOAD ANCHOR
TYPICAL WINDLOAD ANCHOR
SECTION 20
E9-3111
E9-3111
SCALE: 1/4 SIZE
0 3 6
E9-8169
SECTION 21
E9-3102
YHC 300 OG Framing Members for Insulating Glazing
Page-13Effective Date: August 16, 2018 | 04-1009-07
SCALE: 1/4 SIZE
0 3 6
90° OUTSIDE CORNER
SINGLE GLAZING 90° OUTSIDE CORNER
90° OUTSIDE CORNER
SINGLE GLAZING
SECTION 22 SECTION 23
*SECTION 22A
*SECTION 23A
90° OUTSIDE CORNER
INSULATING GLAZING
E9-3107 E9-3111
E9-3107
E9-9303 E9-9303
E9-3161 E9-3161
E 9-
E 9-
E9-3
E9-1
E9-3
STANDARD 90° CORNERS
OPTIONAL 90° CORNER
E9-3174
E9-3174
E9-3145
E9-3
E9-3
E9-1
E9-3176
E9-3146
AS-3177
AS-3175
E9-3111
AS-3172AS-3173
*SECTION 22A & 23A - OPTIONAL 90° CORNERS SHOWN
ABOVE, NOT CURRENTLY APPROVED IN FLORDIA
FOR DESIGN PRESSURES OF 45-55 PSF
Page-14 04-1009-07 | Effective Date: August 16, 2018
SHALLOW DOOR FRAMING MEMBERS WITH INSULATED
GLAZING FOR DESIGN PRESSURES OF 45-55 PSF
AS-0218
AS-0520
AS-0501
AS-3178
AS-3178
E9-3126
E9-3126
E9-3161
E9-3161
AS-0504
AS-0504
AS-3178
AS-3178
E9-8169
E 9-
E 9-
SECTION 24
25 25A
26A
24A
SECTION 25
SECTION 26* SECTION 26A**
AIR TIGHT THRESHOLD
**NOT APPROVED
FOR FLORIDA
SECTION 25A
SECTION 24A
Page-15Effective Date: August 16, 2018 | 04-1009-07
SECTION 27
SECTION 28
27A
29 29A
28A
SECTION 29* SECTION 29A**
SECTION 28A
SECTION 27A
AIR TIGHT THRESHOLD
**NOT APPROVED
FOR FLORIDA
DOOR FRAMING MEMBERS WITH SINGLE GLAZING
FOR DESIGN PRESSURES OF 45-55 PSF
Page-21Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Single Glazing
TYPICAL DEADLOAD ANCHOR
TYPICAL WINDLOAD ANCHOR
SECTION 7
SECTION 8
SCALE: 1/4 SIZE
0 3 6
E9-3103
E9-3103
E9-3106
E9-3106
FOR DESIGN PRESSURES OF 65-90 PSF
Page-22 04-1009-07 | Effective Date: August 16, 2018
YHC 300 OG Curtain Wall SystemYHC 300 OG Framing Members for Insulating Glazing
SCALE: 1/4 SIZE
0 3 6
SECTION 13
JAMB SECTION 14
MULLION @ SPLICE
SECTION 10
HEAD w/ “F” Anchor
SECTION 10A
HEAD w/ “T” Anchor
SECTION 11A
HORIZONTAL (Two-Piece)
SECTION 11
HORIZONTAL (One Piece)
E9-3101
E9-3161
E 9-
3” [76.2mm]
7-
/1 6”
[1
.3 m m
E 9-
E9-3161
SECTION 11B
HORIZONTAL
(Optional Glazing)
SECTION 14A
MULLION w/STEEL
AS REQUIRED
AS-3178
E 9-
E9-3162
E 9-
E9-3162 E
9-
E9-3162
AS-3178
E9-3101 E9-3101
10A
14A
13 14
OPP.
12A
11A
SECTION 12A
SILL w/ “T” Anchor
SECTION 12
SILL w/ “J” Anchor
AS-3172
E 9-
E9-3141
AS-3172
E 9-
E9-3162E9-3102
E 9-
E9-3162
E1-0175
OPTIONAL 1” GLAZING
(For Non-Impact Conditions)
Page-23Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Insulating Glazing
TYPICAL DEADLOAD ANCHOR
TYPICAL WINDLOAD ANCHOR
SECTION 7
SECTION 8
SCALE: 1/4 SIZE
0 3 6
E9-3101
E9-3101
Page-24 04-1009-07 | Effective Date: August 16, 2018
SCALE: 1/4 SIZE
0 3 6
SECTION 9A
90° OUTSIDE CORNER
SINGLE GLAZING
SECTION 18A
90° OUTSIDE CORNER
SECTION 9
90° OUTSIDE CORNER
SINGLE GLAZING
SECTION 18
90° OUTSIDE CORNER
INSULATING GLAZING
E9-3103 E9-3101
E9-3103
E9-9303 E9-9303
E9-3161 E9-3161
E 9-
E 9-
E9-3
E9-1
E9-3
OPTIONAL 90° CORNER
STANDARD 90° CORNERS
E9-3174
E9-3174
E9-3145
E9-3
E9-3
E9-1
E9-3176
E9-3146
AS-3177
AS-3175
E9-3101
AS-3172AS-3173
Page-25Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Door Framing Members
AIR TIGHT THRESHOLD
**NOT APPROVED
FOR FLORIDA
Page-26 04-1009-07 | Effective Date: August 16, 2018
YHC 300 OG Curtain Wall SystemYHC 300 OG Door Framing Members
AIR TIGHT THRESHOLD
**NOT APPROVED
FOR FLORIDA
DOOR FRAMING MEMBERS WITH INSULATING GLAZING
Page-30 04-1009-07 | Effective Date: August 16, 2018
YHC 300 OG Curtain Wall SystemYHC 300 OG Framing Members for Single Glazing
SCALE: 1/4 SIZE
0 3 6
1A
5A
3A
9A
2A
SECTION 1
HEAD w/ “F” Anchor
SECTION 1A
HEAD w/ “T” Anchor
2B
SECTION 2
HORIZONTAL (One Piece)
SECTION 3A
SILL w/ “F” Anchor
E -3
E -3
E9-3188AS-3179
E -3
E9-3188
E9-3190
E -3
E -3
AS-3173
E -3
E -3
E -3
E9-3188
SECTION 2B
HORIZONTAL
(Optional Glazing)
E9-3188
E -3
E -3
E -3
E -3
E9-3188
SECTION 3A
SILL w/ “T” Anchor
SECTION 2A
HORIZONTAL (Two Piece)
E9-3188 E
-3
E -3
OPTIONAL 1/4” GLAZING
(For Non-Impact Conditions)
FOR DESIGN PRESSURES OF 90-130 PSF
Page-31Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Single Glazing
SECTION 4
JAMB
1A
5A
4 5
3A3
9A
2A
E9-3182
E9-3161 3” [76.2mm]
9- 3/
4” [2
.7 m m
2B
SECTION 5
MULLION
E9-3182
SECTION 5A
MULLION w/STEEL
AS REQUIRED
E9-3182
E9-3161
SECTION 6
MULLION @ SPLICE
E9-3182
E9-3161
AS-3179 AS-3173
SCALE: 1/4 SIZE
0 3 6
E1-3031
OPTIONAL 1” GLAZING
(For Non-Impact Conditions)
Page-32 04-1009-07 | Effective Date: August 16, 2018
YHC 300 OG Curtain Wall SystemYHC 300 OG Framing Members for Single Glazing
TYPICAL DEADLOAD ANCHOR
TYPICAL WINDLOAD ANCHOR
SECTION 7
SECTION 8
SCALE: 1/4 SIZE
0 3 6
E9-3182
E9-3182
E9-3190
E9-3190
E 9-
E 9-
Page-33Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Insulating Glazing
SCALE: 1/4 SIZE
0 3 6
SECTION 10
HEAD w/ “F” Anchor
SECTION 10A
HEAD w/ “T” Anchor
SECTION 11
HORIZONTAL (One Piece)
SECTION 11A
HORIZONTAL (Two Piece)
SECTION 12
SILL w/ “F” Anchor
E -3
E9-3188
E -3
E9-3188
E9-3185
E -3
E -3
E -3
E -3
E -3
E9-3188
E9-3188
E -3
E -3
E9-3188
SECTION 12A
SILL w/ “T” Anchor
E -3
AS-3178
AS-3172
E9-3141
E9-3141
10A
14A
OPP.
12A
11A
SECTION 11B
HORIZONTAL
(Optional Glazing)
OPTIONAL 1” GLAZING
(For Non-Impact Conditions)
Page-34 04-1009-07 | Effective Date: August 16, 2018
SECTION 13
JAMB
E9-3183
E9-3161 3” [76.2mm]
-1
/2
6.
7m m
SECTION 14
MULLION
MULLION MULLION
SECTION 14A
w/STEEL
AS REQUIRED
E9-3183
E9-3161
AS-3178
SCALE: 1/4 SIZE
0 3 6
E1-3031
10A
14A
13 14
OPP.
12A
11A
E9-3183
AS-3172
SECTION 15
@ SPLICE
E9-3183
E9-3161
OPTIONAL 1” GLAZING
(For Non-Impact Conditions)
Page-35Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Framing Members for Insulating Glazing
TYPICAL DEADLOAD ANCHOR
TYPICAL WINDLOAD ANCHOR
SECTION 7
SECTION 8
SCALE: 1/4 SIZE
0 3 6
E9-3183
E9-3182
E9-3185
E 9-
E9-3185
E 9-
Page-36 04-1009-07 | Effective Date: August 16, 2018
SECTION 9
90° OUTSIDE CORNER
SINGLE GLAZING
SECTION 18
90° OUTSIDE CORNER
INSULATING GLAZING
STANDARD 90° CORNERS
E9-3182
E9-3182
E9-9303
E9-3161
E 9-
AS-3173
E9-3183
E9-9303
E9-3161
E 9-
E9-3183
AS-3172
SCALE: 1/4 SIZE
0 3 6
Page-37Effective Date: August 16, 2018 | 04-1009-07
SCALE: 1/4 SIZE
0 3 6
SECTION 9A
SECTION 18A90° OUTSIDE CORNER
SINGLE
INSULATING GLAZING
GLAZING 90° OUTSIDE CORNER
E9-3
E9-1
E9-3
OPTIONAL 90° CORNER
E9-3174
E9-3174
E9-3145
E9-3
E9-3
E9-1
E9-3176
E9-3146
AS-3177
AS-3175
Page-38 04-1009-07 | Effective Date: August 16, 2018
YHC 300 OG Curtain Wall SystemYHC 300 OG Door Framing Members
Page-39Effective Date: August 16, 2018 | 04-1009-07
YHC 300 OG Door Framing Members
AIR TIGHT THRESHOLD
**NOT APPROVED
FOR FLORIDA
Page-40 04-1009-07 | Effective Date: August 16, 2018
Page-41Effective Date: August 16, 2018 | 04-1009-07
AIR TIGHT THRESHOLD
**NOT APPROVED
FOR FLORIDA
TEST REPORT
Report No.: F3753.02-550-18
Rendered to:
YKK AP AMERICA, INC
Austell, Georgia
PRODUCT TYPE: Curtain Wall
SERIES/MODEL: YHC 300 OG – Elevation 2
Title Summary of Results
Design Pressure ±2633 Pa (±55.00 psf)
Uniform Load Structural Test Pressure ±3950 Pa (±82.50 psf)
Large Missile Test Pass
Reference must be made to Report No. F3753.02-550-18, dated 04/21/16 for complete test specimen description and detailed test results.
Test Report No.: F3753.02-550-18 Revision 2: 04/21/16
Report Date: 04/11/16
1.0 Report Issued To: YKK AP America, Inc.
270 Riverside Parkway, Suite A Austell, Georgia 30168 Don Pangburn
2.0 Test Laboratory: Architectural Testing, Inc., an Intertek company ("Intertek-ATI") 1701 Westfork Drive, Suite 106 Lithia Springs, Georgia 30122 770-941-6916
3.0 Project Summary:
3.1 Product Type: Curtain Wall
3.2 Series/Model: YHC 300 OG – Elevation 2
3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). Test specimen description and results are reported herein.
3.4 Test Date(s): 03/15/16 – 03/16/16
3.5 Test Record Retention End Date: All test records for this report will be retained until March 16, 2020.
3.6 Test Location: Intertek-ATI test facility in Lithia Springs, Georgia.
3.7 Test Specimen Source: The test specimen was provided by the client. Representative samples of the test specimen(s) will be retained by Intertek-ATI for a minimum of four years from the test completion date.
3.8 Drawing Reference: The test specimen drawings have been reviewed by Intertek-ATI and are representative of the test specimen(s) reported herein. Test specimen construction was verified by Intertek-ATI per the drawings located in Appendix C. Any deviations are documented herein or on the drawings.
3.9 List of Official Observers:
Name Company
Don Pangburn YKK AP America, Inc.
Shane Tanner YKK AP America, Inc.
Jon Gardner Intertek-ATI Darrell Lewis Intertek-ATI Ian McKenzie Intertek-ATI Jacques Johnson Intertek-ATI
4.0 Test Method(s):
ASTM E330/E330M-14, Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
ASTM E1886-13a, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
ASTM E1996-14a, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
5.0 Test Specimen Description:
5.1 Product Sizes:
Overall Area:
14.8 m² (158.83 ft2)
Width Height millimeters inches millimeters inches
Overall size 4,648 183 2,515 99
5.2 Frame Construction:
Frame Member Material Description
Head/Sill
Aluminum 6063-T5
Part #E9-3127 (Middle and Right Bays), #E9-3112 (Left Bay)
Head/Sill Filler Part #E9-8169
Jambs/Mullions Part #E9-3126
Head/Sill/Jamb Pressure Plate Part #AS-3178
Mullion Pressure Plate Part #AS-3172
Pressure Plate Cover Part #E9-3161
Location Joinery Type Detail
Intermediate mullions at head and sill
Square cut and butted
Part #HF2510-W1 (two per side) 1/4"-20 x 5/8" HMHTCS Type F
Top and bottom corners
Square cut and butted
Part #HF2510-W1 (two side by side connecting head and sill to the jambs).
5.0 Test Specimen Description: (Continued)
5.3 Reinforcement: Reinforcement was not utilized.
5.4 Weatherstripping:
Description Quantity Location
Pressure Plate Gasket (Part #E2-0379)
13 rows Faces of the mullion and pressure plates
5.5 Glazing: No conclusions of any kind regarding the adequacy or inadequacy of the glass in any glazed test specimen(s) can be made.
Glass Type
Overall Thickness
Glass Makeup Glazing Method
GI 1-5/16"
1/4" tempered glass
1/2" air space
1/4"heat-strengthened glass
0.060" (Saflex - PVB) interlayer
1/4" heat-strengthened glass
Exterior Dry-Glazing – Pressure Plate (Part #AS-3172) with gasket (Part #E2-0379
Interior Dry Glazing – Gasket (Part # E20379)
CI 1-5/16"
1/4" tempered glass
1/2" air space
1/4"heat-strengthened glass
0.060" (SentryGlass) interlayer
1/4" heat-strengthened glass
Exterior Dry-Glazing – Pressure Plate (Part #AS-3172) with gasket (Part #E2-0379
Interior Dry Glazing – Gasket (Part # E20379)
Glass Type Location Quantity Daylight Opening
Glass Bite millimeters inches
CI All lites 3 1448 x 2362 57 x 93
5.6 Drainage: No drainage was utilized.
6.0 Installation:
The specimen was installed into a steel test buck. The rough opening allowed for a 1/2" shim space. The exterior perimeter of the window was sealed with structural sealant.
Location Anchor Description Anchor Location
Intermediate Mullions
Part #E1-3046 Head and sill of intermediate mullions attached to the steel with 3/8-16 x 1" LG HH Bolts
Top and bottom of jambs
Part #E1-3004 Head and sill of jambs anchored on the steel with two (2) 3/8-16 x 1" LG HH Bolts
7.0 Test Results: The temperature during testing was 25°C (77°F). The results are tabulated as follows:
Title of Test Results Allowed Note
Uniform Load Deflection, ½ of Test Load per ASTM E330
Deflections taken at one intermediate mullion +1976 Pa (+41.25 psf) -1976 Pa (-41.25 psf)
5.6 mm (0.22")
6.6 mm (0.26")
14.0 mm (0.55") max.
14.0 mm (0.55") max. 1, 2
Uniform Load Structural, Design Load per ASTM E330 Deflections taken at one intermediate mullion +2635 Pa (+55.00 psf) -2635 Pa (-55.00 psf)
7.9 mm (0.31")
8.9 mm (0.35")
14.0 mm (0.55") max.
14.0 mm (0.55") max. 1, 2
Uniform Load Deflection, Test Load per ASTM E330 Permanent sets taken at one intermediate mullion +3952 Pa (+82.50 psf) -3952 Pa (-82.50 psf)
1.0 mm (0.04")
1.5 mm (0.06")
5.1 mm (0.20") max.
5.1 mm (0.20") max. 1, 2
7.0 Test Results: (Continued)
ASTM E1886 and ASTM E1996, Large and Small Missile Impact
Conditioning Temperature: 26.7°C (80°F) Large Missile Weight: 4082g (9.0 lbs) Large Missile Length: 2.5 m (8'4") Small Missile Weight: 2g
Elevation 2: Orientation within ±5° of horizontal
Impact #1 (Small Missile): Missile Velocity: 40.1 m/s (131.5 fps)
Impact Area: Bottom of center lite at the midpoint
Observations: Missile hit target area. No signs of penetration.
Results: Pass
Impact #2 (Small Missile): Missile Velocity: 39.9 m/s (130.8 fps)
Impact Area: Geometric center of center lite
Impact #3 (Small Missile): Missile Velocity: 39.5 m/s (129.5 fps)
Impact Area: Top of center lite at the midpoint
Impact #4 (Large Missile): Missile Velocity: 15.4 m/s (50.4 fps)
Impact Area: Bottom right corner of left lite
Impact #5 (Large Missile): Missile Velocity: 15.2 m/s (49.8 fps)
Impact Area: Top right corner of right lite
Note: See Elevation 2 drawings for impact locations
Conclusion: The large and small missiles impacted each intended target and Intertek-ATI carefully inspected each impact location. Intertek-ATI observed no signs of penetration, rupture, or opening after the large missile impact test; as such, each test specimen satisfies the large and small requirements of ASTM E1886 and ASTM E1996.
ASTM E1886 and ASTM E1996, Air Pressure Cycling
Test Unit: Elevation 2 Design Pressure: ±2633 Pa (±55.0 psf)
POSITIVE PRESSURE
Pressure Range
Pa (psf)
Number of Cycles
Average Cycle Time
(seconds) Observations
527 to 1317 (11.0 to 27.5)
3500 2.6
No damage to the frame or deglazing of the glass
0 to 1580 (0 to 33.0)
300 2.9
1317 to 2107 (27.5 to 44.0)
600 2.4
790 to 2633 (16.5 to 55.0)
100 2.8
NEGATIVE PRESSURE
Pressure Range
Pa (psf)
Number of Cycles
Average Cycle Time
(seconds) Observations
790 to 2633 (16.5 to 55.0)
50 3.0
No damage to the frame or deglazing of the glass
1317 to 2107 (27.5 to 44.0)
1050 2.3
0 to 1580 (0 to 33.0)
50 3.0
527 to 1317 (11.0 to 27.5)
3350 2.6
General Note: All testing was performed in accordance with the referenced standard(s).
Note 1: Loads were held for 30 seconds.
Note 2: Tape and film were used to seal against air leakage during structural testing.
8.0 Test Equipment:
Cannon: Constructed from steel piping utilizing compressed air to propel the missile
Missile: 2x4 Southern Pine and 8 mm (5/16") diameter ball bearings
Timing Device: Electronic Beam Type
Cycling Mechanism: Computer controlled centrifugal blower with electronic pressure measuring device
Deflection Measuring Device: Linear transducers
Intertek-ATI will service this report for the entire test record retention period. Test records such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Intertek-ATI for the entire test record retention period.
This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Intertek-ATI.
For ARCHITECTURAL TESTING, INC.:
Jacques R. Johnson Ian J. McKenzie Quality Manager Lab Manager - Regional Operations
JRJ:IJM:jab
Attachments (pages): This report is complete only when all attachments listed are included.
Appendix A: Location of air seal (1) Appendix B: Photograph(s) (1) Appendix C: Drawings (5)
Revision Log
Rev. # Date Page(s) Revision(s)
0 04/11/16 N/A Original report issue
1 04/15/16 Cover Changed the cover page job number to reflect the job number in the header.
2 04/21/16 Drawings Update drawings
This report produced from controlled document template ATI 00479, revised 06/19/15.
Appendix A
Location of Air Seal: The air seal between the test specimen and the test wall is detailed below.
The seal is made of foam weatherstripping and is attached to the edge of the test specimen buck.
The test specimen buck is placed against the test wall and clamped in place, compressing the weatherstripping and creating a seal.
Test Specimen Buck
Air seal between test buck and test wall (typically foam weatherstripping)
Test Specimen
Air seal between test specimen and test buck (typically silicone)
Test Wall
Appendix B
Photographs
Photo No. 1 Test Specimen After Large and Small Missile Impacts
Appendix C
Drawings
F.O. = 184 1/4" v•· I: c• • ,,,.
$I AA--, I 1 · ,,..., " Q]'\_J I: ,. ,,,..., ,,. ®---
;1!" 1 {};RY
c:i I "-
FRAME
FRAME
DRY
ELEVATION 2
OPENING
OPENING
WIDTH
HEIGHT
57"
~y
184 i'' 100 ~,, x
5/B"
'° m
OPP
IMPACT LOCATION LEGEND
x LARGE MISSILE IMPACT LOCATION
® SMALL MISSILE IMPACT LOCATION
GLASS TYPE
<§9 1 5/ 16" 0.060 SAFLEX: (S.M.)
1/4" HEAT STRENGTHENED GLASS +
0.0 60" SAFLEX (PVB) +
1/4" HEAT STRENGTHENED GLASS w/
1/ 2" AIR SPACE + 1 /4" TEMPERED
GLASS
Imm ~
---·~-~I
~ 1 5/16" 0.0 60 SENTRYGLASSo (LARGE MISSILE) {DRY GLAZED)
1/4" TEMPERED GLASS + 1 /2 " AIR SPACE +
1/4" HEAT STRENGTHENED GLASS + D.060" SENTRYGLASS +
1/4" HEAT STRENGTHENED GLASS
NOTE:
1. DESIGN PRESSURE LOAD ~ 55psf .
2. STRUCTURAL ONLY, (NO AIR & WATER)
ANCHOR TYPE
(f): 'F' ANCHOR
CD : T ANCHOR
VKK
aP.
!YS:TD
YHC 300 O.G. (55 p.•.f.)
SHAll.OW MULLION
OCsatll"liil'I
FORMAL MOCK-UP TEST
PAINTED
ELEV-2
''"' 9/30/ 15 AP'P~DVED !ll I DR~WN )'j
DP AA.
M:\Praducl 1-ams\W"ll T•am\C~ri<lln Wllll\YHDDD 00\T•~I D1>cum•n1a\T11k..:>rt Dniwrng~\ Et.Yallans\EI.,. 2 .dw51
G t2-0J79
~I H>-2520->\'3 ~ 1/4•-zo 1<11 1/4• ~ HWHlllS i @ •• o.c.
Jr
J.000" (7S.20)
5.li9BJ" (14+.H]
J.220 " [BUt;i)
2.+4!!" [~2.11'!1]
+.95r (125.77) J.010" (71:1.+6]
E9-J127
Jr G
~I .I
~t-3161
SEE Nj"' :x:1 O'· I HD-2520 - J i....~ I'll 1/ +"-'Xl x , ~ HWHMS i 0 ,. o.c.
"O ~I
5 . 5933. [1 44.7+]
+.952" (12'.77)
FC-1220 (2)
# 12 :ic I 1/4" H1SlilS lYPE "NJ"
3 .220" [111.7!il)
[9-3112
J.010" (75.~)
~I t
E9-J151 i'fl-2520-W3 1 /4°-20 • , 1/4"
HWHMS
0 9" o.c.
·-1~ ci t
H0- 2520-WJ
l/+"-2Q K 1
HWHMS
0 9" o.c.
·1" o~ ci
E~-J1~1
~I S:EE NOTE #2.·
l<l-2~20-WJ.
1/'f"-20 • , 1/+"
HWH"5
o Ii" o_c
SILICON£
S:rALANT
HF- 2510-W l (2) 1/+'-2D • !i/8 ' HWHTCS T'l"PE " r'
YKK
SR
YKI< AP AmtrlC(I In c.
2?C flhoenldt Potkwgy, S.."h I\ Au.tol ' C-. 301 6& (PllJ171.1311..!l:XIQ (l"Nl) U ll.8311.IOSt
"• "_,,,, P I I I I I I
[!il-J127 rc-1120 (2)
112 ~ 1 1/ +" FHSMS
TVP£ "AB '
!5.!!i!5GQ" (14-3.!51]
E2-0;:17~
~UCONE
S£AWlT SPECTRElll 2
SUCONE
SEAWIT
SP'ECTREWI 2
~-251 0-Wl (2) 1;+· - 20 x 5/8.
HWHTCS 'N'Pf "F"'
HF-2510-W I (2)
1/+"-,2_0 • :i/8" HWHTCS 'N'P£ "r'"
El -JOJO
8 i ~ -j
~i i ,, '.)! '" '°'' 1•-1/ 11 'I I '~' I "-FC-1220 (2) I ~ '""' ~ ~ NOTE 1: 5/16 WEEP HOLES @ 1/3 PTS. ~ E2- 0>79-f ~ *'". 1.'/•' FHSMS "''""'' 10/0Z/16 ~
+ TI'PE AB al'J"1'~ ~~ 5HU 1 ~o.: ., NOTE 2: 5/16" WEEP HOLES 3" FROM EACH END & (1) @ CENTER ~ l'"oc•=~· 1 J
.... ii~~
-w: .........:....--...;.:'-'~
D
"'I H0-25ZD-W;5 "' 1/4~-~o x 1 1;4~
~ HWH~S
:-- IJ 'ii~ o.c.
·I§ i:'.'
---. H0-2520-W:S ~ ... 1 ~ l / 4-"-20 x , i.... ~ HWHMS
:--- Iii 9• oc
E9-J127
NOTE 1:
NOTE 2:
['9- 312
5/16" WEEP
5/16" WEEP
HOLES
HOLES
E9-312
J .000" [75. 20]
_.......---ES-.3126
[2- 0379
O.L O
E9-3161
0.L.O
@ 1 /3 PTS.
3" FROM EACH EN D & ( 1) @ CENTER
E2-0JJg
YKK
SR
YKI< AP AmtrlC(I In c.
2?C flhoenldt Potkwgy, S.."h I\ Au.tol ' C-. 301 6& (PllJ171.1311..!l:XIQ (l"Nl) U ll.8311.IOSt
8 i ~ -j
~i i ~~=---., .. ,,;;;"'-;;~m-""1 ~ A:J Nctcd Hl/ OZ/ 16 ~
,, 6 2 n _J~
El-301-15
J/8-1 6 ic 1~ LC.
HH BOllS ilt.T ~U U.JONS
[9-J104 h
_______j___ 2·1
I I - o·'
,0.:1-'goC
I 0 ,70GDO
HEAD / SILL PREP
d
YKK
SR
YKI< AP Amtrl C(I In c.
2?C flhoenldt Potkwgy.
s.;n I\ Au.tol ' c-. 301 6& (PllJ171.1311..!l:XIQ (fNl) U ll.8311.IOSt
F ~j
'i r;;
~~~! l--+-+--+---------+-----1 ih ~ 0-t--t---+----------+-'
~<5~t---ct--f-c-~+----------+---I ~j[~ cAfj Ml ;~~
CHJl'~["O
CL
w Cl:'.
CL
_J _J U1
<l'.
w I
- ·r'--1 f ~
(NOlllnN IMlTWHS) dn >1:xm is31 co OOi:::>HA I "NOLLY.l010N'l"~l'N.L'.)Jl"Ctld i!!l
TYPE: Glazed Wall System
Report No:
Report Date:
D5331.01-116-45 03/10/14
AAMA 507-12 THERMAL PERFORMANCE REPORT
Rendered to:
YKK AP AMERICA
SERIES/MODEL: YHC 300 OG Curtain Wall
Architectural Testing
130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax: 717-764-4129 www.archtest.com
Simulation Date:
Simulation Specimen Description:
Material Finish: Painted Aluminum
Report No: D5331.01-116-45 Report Date: 03/10/14
Configuration: Two vision lites separated by one intermediate vertical Drawing Reference: YKK Drawing YHC 300 O.G., dated 10/09/13
Frame Material: Aluminum Thermally Improved Framing System
Specimen Size: 2000mm wide by 2000mm high (78-3/4" by 78-3/4")
Series/Model: YHC 300 OG Curtain Wall Type: Glazed Wall System
AAMA 507-12, Standard Practice for Determining the Thermal Performance Characteristics of Fenestration Systems Installed in Commercial Buildings
NFRC 100-2010, Procedure for Determining Fenestration Product U-Factors
NFRC 200-2010, Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence
Project Summary:
Reference Documents:
Rendered to:
YKK AP AMERICA
1229 Highway 441 Bypass
Architectural Testing, Inc. was contracted by YKK AP America to provide U-Factor and Solar Heat Gain Coefficient thermal performance ratings on the YHC 300 OG Curtain Wall Glazed Wall System. The thermal performance ratings were determined in accordance with AAMA 507-12, Standard Practice for Determining the Thermal Performance Characteristics of Fenestration Systems Installed in Commercial Building.
03/10/14
Dublin, Georgia 31021
AAMA 507-12 THERMAL PERFORMANCE REPORT
phone: 717-764-7700
D5331.01-116-45
YKK AP America YHC 300 OG Curtain Wall - Glazed Wall System
System U-Factor vs. Percentage of Vision Area
Vision Area / Total Area (%)
Sy st em U
-F ac to r (
B tu
/h ∙ft
2 ∙ºF
Note: 1-5/16 inch Overall - Dual Glazed Laminated Glass (0.48-0.20 COG) with Aluminum Spacer, Dual Glazed Laminated Glass with Heat Mirror (0.18-0.10 COG) with Aluminum Spacer
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.18
0.16
0.14
0.12
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
707580859095
COG
U-Factor
YKK AP America YHC 300 OG Curtain Wall - Glazed Wall System
System SHGC vs. Percentage of Vision Area
Vision Area / Total Area (%)
System VT vs. Percentage of Vision Area
Vision Area / Total Area (%)
Sy st em S
H G
C Sy st em
V T
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
707580859095
COG SHGC
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
707580859095
COG VT
YKK AP America YHC 300 OG Curtain Wall - Glazed Wall System
0.16
Note: 1-5/16 inch Overall - Dual Glazed Laminated Glass (0.48-0.20 COG) with Aluminum Spacer, Dual Glazed Laminated Glass with Heat Mirror (0.18-0.10 COG) with Aluminum Spacer
0.41 0.39 0.37 0.35 0.34
19 0.12 0.30
20 0.10 0.29
12 0.26 0.42
18 0.14 0.32
0.24 0.22 0.20 0.18
Size Specific U-Factor Matrix* Glazing Option Center of Glass U-Factor Overall U-Factor
1 0.48 0.60 2 0.46 0.59 3 0.44 0.57 4 0.42 0.55 5 0.40 0.54 6 0.38 0.52 7 0.36 0.50 8 0.34 0.49
11 0.28 0.44
9 0.32 0.47 10 0.30 0.46
YKK AP America YHC 300 OG Curtain Wall - Glazed Wall System
0.05 0.06 0.05 0.04
*Size Specific U-Factor, SHGC, and VT Matrices are based on the standard Glazed Wall System specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4").
This represents 88.9% Vision Area / Total Area.
0.15 0.15 0.15 0.13
0.10 0.10 0.10 0.09
0.25 0.24 0.25 0.22
0.20 0.19 0.20 0.18
0.35 0.33 0.35 0.31
0.30 0.28 0.30 0.26
0.45 0.41 0.45 0.40
0.40 0.37 0.40 0.35
0.55 0.50 0.55 0.49
0.50 0.46 0.50 0.44
0.65 0.59 0.65 0.57
0.60 0.55 0.60 0.53
0.75 0.68 0.75 0.66
0.70 0.63 0.70 0.62
Size Specific SHGC Matrix* Size Specific VT Matrix* Center of Glass SHGC Overall SHGC Center of Glass VT Overall VT
R. Jamb
1.5732 1.5732
1.5732 1.5732
1.5732
Head
L. Jamb R. Jamb
L. Jamb R. Jamb
L. Jamb R. Jamb
L. Jamb
Head
Mullion
0.46
0.44
44.8
L. Jamb 0.5212
0.4521
0.5540
0.5376
0.8007
0.7881
Sill
Fr am e H ei gh t
Head L. Jamb R. Jamb Mullion
3.1463
1.5732
Mullion Sill
R. Jamb Mullion Sill Head
1.5732
1.6715 1.6713
L. Jamb
1.5732 1.5732
3.1463
L. Jamb R. Jamb
1.5732 1.5732
Head
Mullion
3.1463 1.5732
1.6807 1.6804
1.6775 1.6773
1.6745 1.6742
Sill Head
L. Jamb R. Jamb
C ro ss S ec tio n Head
Mullion Sill
Mullion
Sill
Mullion Sill Head
Mullion
0.42
0.40
0.348
0.38
0.36 1.6683 1.6682
1.6655 1.6654
51.0
1.6683
1.6153
C O
G U
-F ac to r
0.481
0.32
C O
G T em pe ra tu re
Head
70% Vision Area
27.84" by
27.84"
Total Product U-Factor
Fr am e U
-F ac to r
145.67"
R. Jamb
Sill
0.4390
0.4134 0.3969
1.6806 1.6435
1.6840
1.5732 1.6744
Vision Area Data
43.7
100-2010 78.74" by
0.44031.5732 0.8387 0.5249
O pt io n
N o.
NFRC
Ed ge
U -F ac to r
1.6774 1.6404 1.6240
78.74"
95% Vision Area
178.15" by
45.8
46.8
47.9
48.9
50.0
1.5732
3.1463 1.5732
3.1463
Sill
52.0
1.6628
1.5732 1.5732
3.1463 1.5732 1.5732 1.5732 1.5732
1.6310
1.6266
0.4392
0.4244 0.4247
0.4100 0.4102
0.3957 0.3959
0.3813 0.3815
3.1463 1.5732 1.5732
3.1463 1.5732
1.5732
1.5732
1.5732 1.5732
1.5732
1.5732
1.5732 0.3673
0.3523
1.6319 1.6163
1.6687 1.6685
0.3847
0.3524
1.6182
1.6686
0.3382 0.3382
1.5732 1.5732
3.1463 1.5732 1.5732
1.6210
1.6714 1.6347
1.6333
1.6838 1.6466 1.6301
1.6375
1.6270
1.6836
1.6655 1.6291 1.6126 1.6628 1.6628
0.4391 0.4425 0.4257
0.4245 0.4279 0.4112
0.4101
0.3958 0.3991 0.3824
0.3814
0.3682
0.3243 0.3242
0.3542
0.3524
0.3671
0.3251
0.3382 0.3414
0.3555
0.8260
0.8133
0.3390
0.7757
0.7637
0.3672 0.3704
0.7391
0.7513
0.5705
0.4720
0.6035
0.5870
0.5049
0.4885
0.5067
0.4702
0.4885
0.4341
0.3803
0.4162
0.3983
0.3243 0.3274
Mullion 3.1463 Sill 1.5732 1.5715 0.1987
1.6163 0.1962 R. Jamb 1.5732 1.6162 0.1962
0.1993 0.6196 0.3194 0.2194 L. Jamb 1.5732 1.6165 0.1961
18 0.14 61.7 Head 1.5732 1.5532
L. Jamb 1.5732 1.6216 0.2232 R. Jamb 1.5732 1.6214 0.2232
1.6215 0.2232 Sill 1.5732 1.5766 0.2258 Mullion 3.1463
17 0.16 60.6 Head 1.5732 1.5556 0.2129 0.6315 0.3360 0.2375 L. Jamb 1.5732 1.6188 0.2097 R. Jamb 1.5732 1.6186 0.2097 Mullion 3.1463 1.6187 0.2097
Sill 1.5732 1.6126 0.2451
0.6650 0.3727 0.2746
Mullion 3.1463 1.6415 0.2419 0.2419
15 0.20 58.4 Head 1.5732 1.5983 0.2427 Sill 1.5732 1.6148 0.2587
3.1463 1.6507 0.2557
14 0.22 57.3 Head 1.5732 1.6004 0.2563 0.2924 Sill 1.5732 1.6170 0.2723
0.6785 0.3897
0.6905 0.4061 0.3101
Mullion 3.1463 1.6529 0.2692 0.2693
13 0.24 56.3 Head 1.5732 1.6027 0.2699 Sill 1.5732 1.6193 0.2860
0.4226 0.3278
Mullion 3.1463 1.6553 0.2829
1.5732 1.6051 0.2836 0.702512 0.26 55.2 Head 0.2997Sill 1.5732 1.6214
0.28 54.2 Head 0.4390 0.3452
Mullion 3.1463 1.6574 0.2966
Sill 1.5732 1.6238
1.5732 1.6072 0.2973 0.714611
0.4555 0.3628
Mullion 3.1463 1.6599 0.3104
1.5732 1.6098 0.3111 0.726710 0.30 53.1 Head
R. Jamb 1.5732 1.6415 L. Jamb 1.5732 1.6415 0.2419
0.2557R. Jamb 1.5732 1.6506 Mullion
L. Jamb 1.5732 1.6507 0.2556
R. Jamb 1.5732 1.6529 L. Jamb 1.5732 1.6529 0.2692
0.2829R. Jamb 1.5732 1.6552 L. Jamb 1.5732 1.6553 0.2829
0.2966R. Jamb 1.5732 1.6574 L. Jamb 1.5732 1.6574 0.2966
0.3135
R. Jamb 1.5732 1.6599 0.3104
0.2554
L. Jamb 1.5732 1.6599 0.3103
145.67"
16 0.18 59.5 Head 1.5732 1.5583 0.6437 0.35260.2265
27.84" 78.74" 178.15" by by by
27.84" 78.74"Fr am e H ei gh t
Fr am e U
-F ac to r
Ed ge
U -F ac to r
Total Product U-Factor
70% NFRC 95%
Vision Area 100-2010 Vision Area
O pt io n
N o.
C O
G U
-F ac to r
C O
G T em pe ra tu re
C ro ss S ec tio n
Sill 1.5732 1.5739 0.2122
Vision Area Data
Sill 1.5732 1.5673 0.1715 Mullion 3.1463 1.6123 0.1689 R. Jamb 1.5732 1.6122 0.1690
0.1721 0.5958 0.2860 0.1830 L. Jamb 1.5732 1.6124 0.1688
20 0.10 63.9 Head 1.5732 1.5490 Sill 1.5732 1.5693 0.1851
Vision Area Data O pt io n N o.
C O
G U
-F ac to r
C O
G T em pe ra tu re
C ro ss S ec tio n
Fr am e H ei gh t
Fr am e U
-F ac to r
Ed ge
U -F ac to r
Total Product U-Factor
70% NFRC 95%
Vision Area 100-2010 Vision Area 27.84" 78.74" 178.15" by by by 27.84" 78.74" 145.67"
19 0.12 62.8 Head 1.5732 1.5510 0.1857 0.6076 0.3027 0.2012 L. Jamb 1.5732 1.6144 0.1825 R. Jamb 1.5732 1.6141 0.1826 Mullion 3.1463 1.6142 0.1826
For ARCHITECTURAL TESTING, INC.:
SIMULATED BY: REVIEWED BY:
AMG:AMG
D5331.01-116-45
Attachments (pages): This report is complete only when all attachments listed are included.
Appendix A: Drawings and Bills of Material (10)
Allison M. Goodyear Kevin S. Louder Simulation Technician Project Engineer
Architectural Testing will service this report for the entire test record retention period. Test records that are retained such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation will be retained by Architectural Testing, Inc. for the entire test record retention period. The test record retention end date for this report is March 10, 2018.
Results obtained are simulated values and were secured by using the designated test methods.
This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the product simulated. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc.
Revision Log
Date Page(s) Revision(s)
Original Report Issued to YKK AP America
Rev. #
All.01R0 03/10/14
All drawings and Bills of Material used in simulating this product are enclosed in this Appendix.
agoodyear D5331-116-45 agoodyear Text Box Material: Painted or Anodized Aluminum agoodyear agoodyear
R
D5331-116-45 agoodyear
Rectangle klivelsberger klivelsberger Rectangle klivelsberger Line klivelsberger Line klivelsberger Line klivelsberger Line
YHC 300 OG Curtain Wall - Dry Glazed
YHC 300 OG Curtain Wall - Wet Glazed
SERIES/MODEL: YHC 300 OG Curtain Wall TYPE: Glazed Wall Systems (Site-built)
Reference must be made to Report No. 93842.02-116-46, dated 10/20/09 for complete test specimen description and data.
Layer 1 1/4" AFG Comfort Ti-AC 40 (e=0.043*, #2) Tempered Unit Size 78-3/4'' x 78-3/4'' (2000 mm x 2000 mm)
Gap 1 0.50'' Gap, Stainless Steel Spacer (SS-D), Air-Filled* Layer 2 0.563 Clear Laminated (0.060 PVB)
AAMA 1503-09 THERMAL PERFORMANCE
TEST REPORT
Rendered to:
YKK AP AMERICA
Thermal Transmittance (U-Factor) Condensation Resistance Factor - Frame (CRFf) Condensation Resistance Factor - Glass (CRFg)
Summary of Results 0.43 phone: 717-764-7700
Report Number:
Test Date:
Report Date:
Expiration Date:
Test Sample Submitted by:
F F
1.
2.
Client
Condensation resistance factor - Glass (CRFg)
1. Average warm side ambient temperature
(U-factors expressed in Btu/hr·ft2·F)
0.43
Test Results Summary:
Condensation resistance factor - Frame (CRFf)
Test Sample Identification:
93842.02-116-46
10/20/09 08/15/13
08/15/09
Series/Model: YHC 300 OG Curtain Wall
Type: Glazed Wall Systems (Site-built)
Test Procedure: The condensation resistance factor (CRF) and thermal transmittance (U) were determined in accordance with AAMA 1503-09, Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections
4. 0.0" +0.04" static pressure drop across specimen.
3. 15 mph dynamic wind applied to test specimen exterior.
69.80 -0.39
Austell, Georgia 30168
2. Average cold side ambient temperature
Thermal transmittance due to conduction (Uc)
AAMA 1503-09 THERMAL PERFORMANCE TEST REPORT
Rendered to:
YKK AP AMERICA
7680 The Bluffs, Suite 100 phone: 717-764-7700
Test Sample Description:
*Stated per Client/Manufacturer NA Non-Applicable See Description Table Abbreviations
White/Brown
78-3/4" x 78-3/4"
Frame
CORNERS
34-7/8" x 72-3/4" (x2)Daylight Opening (in.)
CONSTRUCTION
Size (in.) Non-Standard
93842.02-116-46
Desiccant Yes
N/A*
0.50'' Gap, Stainless Steel Spacer (SS-D), Air-Filled*
0.563 Clear Laminated (0.060 PVB)
1/4" AFG Comfort Ti-AC 40 (e=0.043*, #2) Tempered
Gap 1
Layer 1
Layer 2
Fasteners
Finish Interior
GLAZING METHOD
Glazing Information:
Finish Exterior
MATERIAL
Anodized
Brown
AU (0.13")
Pressure
Anodized
Color Interior
YesSealant
Color Exterior
Screws
Butt
Gas Fill Method
Test Sample Description: (Continued)
Aluminum pressure plates
DRAINAGE
No visible weeps
4 Horizontal, 3 vertical at exterior glazing edges 4 Horizontal, 3 vertical at pressure plates
EPDM Pressure gasket
Interior glazing perimeter, exterior glazing perimeter, and between
WEATHERSTRIP
1 Row
Quantity LocationType
Aluminum snap cover
COMPONENTS
93842.02-116-46
HARDWARE
Test Duration:
1.
2.
Condensation Resistance Factor (CRF):
= F = F = F = F = F = F
Th
Tc
FTp
FTr
W
FT
GT
50.73 44.83
(FTp - FTr) / [FTp - (Tc + 10)] x 0.40
Warm side ambient air temperature Cold side ambient air temperature Average of pre-specified frame temperatures (14) Average of roving thermocouples (4)
The thermal performance test results were derived from 03:59 hours, 08/15/09 to 07:59 hours, 08/15/09.
The environmental systems were started at 12:27 hours, 08/14/09.
0.057
The following information, condensed from the test data, was used to determine the condensation resistance factor:
69.80 -0.39
FTp(1-W) + W (FTr) = Frame Temperature Glass Temperature Condensation resistance factor – Glass CRFg = (GT - Tc) / (Th - Tc) x 100
47.47
CRFf = (FT - Tc) / (Th - Tc) x 100
CRFg
CRFf Condensation resistance factor – Frame
The CRF number was determined to be 68 (on the size as reported). When reviewing this test data, it should be noted that the glass temperature (GT) was colder than the frame temperature (FT) therefore controlling the CRF number. Refer to the 'CRF Report' page and the 'Thermocouple Location Diagram' page of this report.
50.39
Th = Average warm side ambient temperature F Tc = Average cold side ambient temperature F P = Static pressure difference across test specimen psf
15 mph dynamic perpendicular wind at exterior Nominal sample area ft2
Total measured input to calorimeter Btu/hr Calorimeter correction Btu/hr Net specimen heat loss Btu/hr Uc = Thermal Transmittance
Prior to testing the specimen was sealed with silicone on the interior side and checked for air infiltration per Section 9.3.4.
0.50
0.44
0.44
Glazing Deflection (in.):
Left Glazing
The sample was inspected for the formation of frost or condensation, which may influence the surface temperature measurements. The sample showed no evidence of condensation/frost at the conclusion of the test.
0.44
0.44Center gap width at laboratory ambient conditions on day of testing Center gap width at test conditions 0.380.38
Right Glazing
Btu/hr·ft2·F
Thermal Transmittance (Uc):
69.80 -0.39 0.00
0.43
43.07 1414.67 106.30
1308.37
93842.02-116-46
Edge Gap Width Estimated center gap width upon receipt of specimen in laboratory (after stabilization)
0.50
A calibration of the Architectural Testing Inc. 'thermal test chamber' (ICN 000001) in York, Pennsylvania was conducted in April 2009 in accordance with Architectural Testing Inc.
calibration procedure.
Time: 05:59 06:29 06:59 07:29 07:59 AVERAGE
Pre-specified Thermocouples - Frame
Warm Side - Room Ambient Air Temperature
47.72 54.19
CRF Report
47.43 48.23
53.95 53.76 52.16 51.88 49.93 50.20 46.13 46.97 55.45 52.11 50.72
47.41 48.22 47.74 54.17
46.17 46.99
53.97 53.76 52.16 51.87
55.45 52.10 50.73
49.93 50.23
47.42
53.98
47.43
48.23 48.24
47.71 47.72
54.18 54.20 53.97
49.93
52.15 51.87
53.77
51.87 49.93
53.75 52.15
50.22
46.17 46.16
46.97 46.97
50.21
55.45
52.12 52.11
50.72 50.73
55.45
47.42 48.23 47.74 54.18
46.14 46.99
53.98 53.77 52.18 51.86
50.73
47.42 48.23 47.72 54.18 53.97 53.76 52.16
49.94 50.20
51.87 49.93 50.21 46.15 46.98 55.45 52.11 50.73
46.24 46.46 54.07
38.71 52.78 46.19 46.43
52.77 52.73 38.58 52.76
54.05 54.03 46.72
54.05 46.74
47.48 47.48
46.75 47.48
46.74
46.21 46.19
54.05 54.05
46.22 46.21
46.46 46.4446.43 46.45
38.64
52.74 52.75
46.75 46.74
42.60 42.60 42.60 42.60
47.46
43.50 43.50
47.47 47.47
42.60 42.60 Cold Point (Roving) Thermocouples
46.20 46.20
43.50 43.50
46.20 46.20 46.20 46.20
43.50 43.50
47.00 47.00 47.00 47.00
0.06 0.06
44.83 44.83 44.83 44.83
47.00 47.00
44.83 44.83
50.39 50.39
0.06 0.06
50.38 50.39 50.39 50.39
0.06 0.06
72 72CRFf
-0.37 -0.37 -0.45 -0.35
69.80 69.80
-0.35 -0.38 Cold Side - Room Ambient Air Temperature
69.80 69.81 69.80 69.80
68 68 72 72 68 68 68 68
72 72
FTP
Pre-specified Thermocouples - Glass
38.6138.67 38.64
55.47 52.10
GT
FT
CRFg
93842.02-116-46
FTR
W
AND IDENTIFY COLD POINTS
Cold Point Locations
43.50
Thermocouple Location Diagram
23.
24.
SELECT DRAWING,
47.00
22.
42.6021.
46.20
DRAG HERE,
For ARCHITECTURAL TESTING, INC.
Benjamin W. Green Shon W. Einsig Technician Senior Technician
Individual-In-Responsible-Charge
BWG:kmm 93842.02-116-46
Attachments (pages): This report is complete only when all attachments listed are included.
Appendix-A:
Appendix-B:
Detailed drawings, data sheets, representative samples of the test specimens, a copy of this report, or other pertinent project documentation will be retained by Architectural Testing, Inc.
until 8/15/2013. At the end of this retention period such materials shall be discarded without notice and the service life of this report by Architectural Testing, Inc. will expire.
Description Table Abbreviations (1)
Results obtained are tested values and were secured by using the designated test methods. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written
Drawings (2)
Date
10/20/09
Revision(s)
Rev. # Page(s)
All
Revision Log
.02R0 Original Report Issue. Work requested by Don Pangburn of YKK AP America.
93842.02-116-46
This report produced from controlled document template ATI 00025, revised 10/08/08..
Frame / Sash Types Aluminum w/ Vinyl Inserts (Caps) Not Applicable Aluminum Aluminum w/ Thermal Breaks - Partial Door Type Aluminum w/ Steel Reinforcement Embossed Aluminum w/ Thermal Breaks - All Members ( > 0.21") Flush Aluminum Thermally Improved - All Members (0.062" - 0.209") Full Lite Aluminum / Vinyl Composite 1/2 - Lite Aluminum-clad Wood 1/4 - Lite Fiberglass 3/4 - Lite ABS Plastic w/ All Members Reinforced Raised Panel ABS Plastic-clad Aluminum ABS Plastic w/ Foam-filled Insulation Skin ABS Plastic w/ Horizontal Members Reinforced Aluminum ABS Plastic w/ Reinforcement - Interlock Fiberglass ABS Plastic Galvanized Steel ABS Plastic w/ Reinforcement - Partial Steel ABS Plastic w/ Vertical Members Reinforced Wood ABS Plastic-clad Wood Vinyl Steel Vinyl w/ All Members Reinforced Panel Vinyl-clad Aluminum Fiberglass Vinyl w/ Foam-filled Insulation Plastic Vinyl w/ Horizontal Members Reinforced Wood - Plywood Vinyl w/ Reinforcement - Interlock Wood - Solid Vinyl w/ Reinforcement - Partial Vinyl w/ Vertical Members Reinforced Sub-Structure Vinyl-clad Wood Galvanized Steel Vinyl Steel Aluminum / Wood composite Wood Wood Vinyl Vinyl / Wood composite Fiberglass/Wood Combination Core Fill Composite/Wood Composite (Shaped vinyl/wood composite members) Cellular - Honeycomb Copper Clad Wood Expanded Polystyrene Vinyl/Wood Composite Material Polyisocyanurate
Polyurethane Tint Codes Wood - Plywood Azurlite Wood - Solid
Spacer Types (See sealant) Blue Extruded Polystyrene Aluminum Bronze Aluminum (Thermally-broken) Clear Spacer Sealant Aluminum-reinforced Polymer Evergreen Dual Seal Spacer System Aluminum / Wood Gold Single Seal Spacer System Aluminum-reinforced Butyl (Swiggle) Green Aluminum / Foam / Aluminum Gray Grid Description Aluminum U-shaped Low 'e' Coating No Muntins Aluminum-Butyl (Corrugated) (Duraseal) Other (use comment field) Grids between glass EPDM Reinforced Butyl Solar or Reflective Coating Simulated Divided Lites Fiberglass Roller Shades between glazing True Muntins Glass Silver (reflective coating) Organic Foam Suspended Polyester Film Duralite Silver Grid Size Codes Polyurethane Foam Blinds between the Glazing Blank for no grids Stainless Steel, U-shaped Dynamic Glazing-Variable Grids < 1" Coated Steel, U-shaped (Intercept) Dynamic Glazing-NonVariable Grids >= 1" Steel (Thermally-broken) Steel / Foam / Steel Gap Fill Codes Steel-reinforced Butyl Air Thermal Breaks Steel U-channel w/ Thermal Cap Argon/Krypton Mixture Foam Stainless Steel Argon / Krypton / Air Urethane Coated Steel Argon/Air Vinyl Thermo-plastic Carbon Dioxide Fiberglass Wood Krypton/Air Other Elastomeric Silicone Foam Sulfur Hexaflouride ABS Silicone Foam Xenon/Krypton/Air Neoprene Silicone / Steel Xenon/Argon/Air Air Not Applicable Xenon/Air Not Applicable
Not Applicable PolyamideN P
XE3 AI
XEN N
SS
SF6 AB
TS Thermo-plastic w/ stainless steel substrate
ZS
N
ZF XE2 NE
ZE
CO2 FB
WD KRY O
TP
AR3 U
CS ARG V
Appendix A: Description Table Abbreviations
CODE DOOR DETAILS
AI N
AL
AP CODE
AS EM
AT FL
AU LF
AV LH
AW LQ
FG LT
PA RP
PC
PF CODE
PH AL
PI FG
PL GS
PP ST
PV WD
PW VY
ST
VA CODE
VC FG
VF PL
VH WP
VI WS
VP
VV CODE
VW GS
VY ST
WA WD
WD VY
WV
WF CODE
WC CH
CW EP
CO PI
PU
CODE WP
AZ WS
BL XP
BZ
A2 CL CODE
A1
A3 EV D
A4 GD S
A5 GR
A6 GY CODE
A7 LE N
A8 OT G
ER RC S
FG RG T
GL RS
OF SF
P1 SR CODE
PU BG
SU DV 0.75
CU DY 1.5
S2
S3 CODE
S5 AIR CODE
S6 AR2 F
CODE
Appendix B: Drawings
NFRC U-FACTOR, SHGC, VT, &
CONDENSATION RESISTANCE
COMPUTER SIMULATION REPORT
Rendered to:
YKK AP AMERICA
SERIES/MODEL:
YHC 300 OG Curtain Wall
Report Number:
Report Date:
D5331.02-116-45 03/10/14 phone: 717-764-7700
NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE
COMPUTER SIMULATION REPORT
Rendered to:
YKK AP AMERICA
1229 Highway 441 Bypass Dublin, Georgia 31021
Report Number:
Simulation Date:
Report Date:
Project Summary:
Standards:
Software:
Simulations Specimen Description:
Series/Model: YHC 300 OG Curtain Wall Type: Glazed Wall System, Curtain Wall Frame Material: AU Thermally Improved Sash Material: NA Not Applicable Standard Size: 2000mm x 2000mm
D5331.02-116-45 03/10/14 03/10/14
Architectural Testing, Inc. was contracted to perform U-Factor, Solar Heat Gain Coefficient, Visible Transmittance, and Condensation Resistance* computer simulations in accordance with the National Fenestration Rating Council (NFRC). The products were evaluated in full compliance with NFRC requirements to the standards listed below.
*NFRC's Condensation Resistance rating is NOT equivalent to a Condensation Resistance Factor (CRF) determined in accordance with AAMA 1503.
NFRC 100-2010: Procedure for Determining Fenestration Product U-Factors NFRC 200-2010: Procedure for Determining Fenestration Product Solar Heat Gain
Coefficient and Visible Transmittance at Normal Incidence NFRC 500-2010: Procedure for Determining Fenestration Product Condensation
Resistance Values
Frame and Edge Modeling: THERM 6.3.46 Center-of-Glass Modeling: WINDOW 6.3.74 Total Product Calculations: WINDOW 6.3.74 Spectral Data Library: IGDB 31.0 phone: 717-764-7700
Modeling Assumptions/Technical Interpretations:
1) To prevent air infiltration, tape was applied to all interior sash crack locations.
2) This product is available in either a painted or anodized finish. These two finish types can be grouped in accordance with NFRC 100-2010, Section 4.2.1.L. The painted finish was simulated since it is the worst case (highest emissivity). The test sample was painted aluminum.
3) The center-line modeling approach was conducted using the horizontal intermediate for the head and sill models, and the vertical intermediate for the jambs. This procedure is outlined in the NFRC Simulation Manual, Section 8.10.
4) This product is available with a dry glazed or wet glazed sealant. These sealant variations were grouped for worst case performance in accordance with NFRC 100-2010, Section 4.2.1.M. The dry glazed version of this product was simulated as the group leader since it is the worst case (highest conductivity).
Specialty Products Table:
SHGC = SHGC0 + SHGCc (SHGC1 - SHGC0) VT = VT0 + VTc (VT1 - VT0)
Validation Matrix:
The specialty products method allow the manufacturer to…