36E77619R0036-0003005.pdf
PDF 462 KB Posted
- Solicitation number
- 36E77619R0036
About this file
36E77619R0036 0003 OBE FG-5100T BlastMax Storefront.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77619C0059-000.docx | DOCX document | |
| 36E77619R0036-0005001.pdf | ||
| 36E77619R0036-0005000.docx | DOCX document | |
| 36E77619R0036-0004001.pdf | ||
| 36E77619R0036-0004000.docx | DOCX document | |
| 36E77619R0036-0003001.pdf | ||
| 36E77619R0036-0003003.pdf | ||
| 36E77619R0036-0003004.pdf | ||
| 36E77619R0036-0003006.pdf | ||
| 36E77619R0036-0003002.pdf | ||
| 36E77619R0036-0003000.docx | DOCX document | |
| 36E77619R0036-0003007.pdf | ||
| 36E77619R0036-0002000.docx | DOCX document | |
| 36E77619R0036-0001000.docx | DOCX document | |
| 36E77619R0036-0001001.pdf | ||
| 36E77619R0036-004.pdf | ||
| 36E77619R0036-007.pdf | ||
| 36E77619R0036-008.pdf | ||
| 36E77619R0036-005.pdf | ||
| 36E77619R0036-002.pdf | ||
| 36E77619R0036-009.docx | DOCX document | |
| 36E77619R0036-006.pdf | ||
| 36E77619R0036-010.pdf | ||
| 36E77619R0036-003.pdf | ||
| 36E77619R0036-001.docx | DOCX document | |
| 36E77619R0036-000.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Series FG-5100T BlastMax™— outside glazed, center set thermally broken blast-resistant storefront system
The FG-5100T BlastMax™ system is a thermally broken blast-resistant storefront system for 1-1/4" insulating laminated glass. This system meets the most demanding requirements of ASTM, GSA and UFC.
Exterior and structural silicone glazed, the FG-5100T offers ease of fabrication and installation. The FG-5100T Storefront System is unique in that it exceeds all blast as well as hurricane standards.
� System dimensions 2-1/2" x 5"
� 1-1/4" laminated insulating glass
� Exterior glazed
� Structural silicone glazed
� No exposed fasteners
� Screw spline joinery
� EZ punch capability
� Integration of MSD-375 entrances
� Optional glazing and fastening to meet both blast and hurricane test standards
� Factory-painted Kynar 500®/Hylar 5000® finishes, meeting all provisions of AAMA 2605
� Factory-anodized finishing
� ASTM F1642 compliant
� UFC (DoD) 4-010-01 compliant
� GSA/ISC compliant
Features series FG -5100T blast-resistant storefront system s
2425 Olympic Boulevard, Suite 525-East � Santa Monica, CA 90404 1-866-OLDCASTLE (653-2278) � oldcastlebe.com
Performance
Blast Resistance
� Air Infiltration: <.06 CFM/SQ FT PSF and 6.24 PSF per ASTM E 283
� Static Water: 15 PSF per ASTM E 331
� Deflection Load: 50 PSF per ASTM E 330
� Structural Load: 50 PSF per ASTM E 330
� ASTM F 1642: No hazard; UFC 4-010-01 Level of protection - Medium; GSA Performance Condition – 3b
Blast and Hurricane Resistance
� Air Infiltration: <.06 CFM/SQ FT PSF and 6.24 PSF per ASTM E 283
� Static Water: 15 PSF per ASTM E 331
� Deflection Load: +50 / -50 PSF per ASTM E330
� Structural Load: +50 / -50 PSF per ASTM E 330
� ASTM F 1642: No hazard; UFC 4-010-01 Level of protection - Medium; GSA Performance Condition – 3b
� Large Missile and Cycling: +50 / -50 PSF per TAS-201, TAS-203 and ASTM E1886, E1996
Details
Horizontal Details Vertical Details series FG -5100T blast-resistant storefront system s
Kynar 500® is a registered trademark of Atofina Hylar 5000® is a registered trademark of Ausimont USA, Inc.