36E77619R0036-0003006.pdf
PDF 363 KB Posted
- Solicitation number
- 36E77619R0036
About this file
36E77619R0036 0003 OBE Reliance BlastMax Curtain Wall.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77619C0059-000.docx | DOCX document | |
| 36E77619R0036-0005001.pdf | ||
| 36E77619R0036-0005000.docx | DOCX document | |
| 36E77619R0036-0004001.pdf | ||
| 36E77619R0036-0004000.docx | DOCX document | |
| 36E77619R0036-0003001.pdf | ||
| 36E77619R0036-0003003.pdf | ||
| 36E77619R0036-0003004.pdf | ||
| 36E77619R0036-0003005.pdf | ||
| 36E77619R0036-0003002.pdf | ||
| 36E77619R0036-0003000.docx | DOCX document | |
| 36E77619R0036-0003007.pdf | ||
| 36E77619R0036-0002000.docx | DOCX document | |
| 36E77619R0036-0001000.docx | DOCX document | |
| 36E77619R0036-0001001.pdf | ||
| 36E77619R0036-004.pdf | ||
| 36E77619R0036-007.pdf | ||
| 36E77619R0036-008.pdf | ||
| 36E77619R0036-005.pdf | ||
| 36E77619R0036-002.pdf | ||
| 36E77619R0036-009.docx | DOCX document | |
| 36E77619R0036-006.pdf | ||
| 36E77619R0036-010.pdf | ||
| 36E77619R0036-003.pdf | ||
| 36E77619R0036-001.docx | DOCX document | |
| 36E77619R0036-000.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R eliance B lastM ax blast-resistant curtain w all
After extensive blast arena testing the Reliance BlastMax™ Blast
Resistant Curtain Wall System has proven to be a high performance system that meets the most exacting standards of ASTM, GSA and UFC. In addition, this system offers ease of fabrication and installation with exceptional water control and outstanding thermal performance. The Reliance BlastMax™ Blast Resistant Curtain Wall
System performs exceptionally well without the need for reinforcing steel or special anchoring.
Features
� System dimensions 2-1/2" x 7-1/2"
� 1-1/4" laminated insulating glass
� Exterior glazed
� Thermally broken
� Wet glazed
� No exposed fasteners
� Integration of MSD-375 entrances with sub-frame
� Factory-painted Kynar 500®/Hylar 5000® finishes, meeting all provisions of AAMA 2605
� Factory-anodized finishing
� ASTM F1642 compliant
� UFC (DoD) 4-010-01 compliant
� GSA/ISC compliant
Harry P. Ward Tower, University of Arkansas Medical Center, Little Rock, AR Architect: Perkins + Will and Stuck Associates
Reliance BlastMax™ Curtain Wall— outside glazed, front set pressure wall curtain wall system
2425 Olympic Boulevard, Suite 525-East � Santa Monica, CA 90404 1-866-OLDCASTLE (653-2278) � oldcastlebe.com
R eliance B lastM ax blast-resistant curtain w all
Details
Performance
� Air Infiltration: <.06 CFM/SQ FT (6.24 PSF) per ASTM E283
� Static Water: 15 PSF per ASTM E331
� Dynamic Water: 15 PSF per AAMA 501.1
� Deflection Load: 40 PSF per ASTM E330
� Structural Load: 60 PSF per ASTM E330
� ASTM F 1642: Minimal hazard
� UFC 4-010-01: level of protection - low
� GSA Performance Condition: 3b