BD Plans 885CM3015 Knoxville.pdf
PDF 8 MB Posted
- Solicitation number
- 36C78624B0024
About this file
This document is a set of construction drawings and project details for the "Knoxville National Cemetery Correct Cemetery Facility Condition Assessment (FCA) Deficiencies" project, which is solicitation number 36C78624B0024.
The key details are:
- The project is located at the Knoxville National Cemetery in Knoxville, Tennessee and is being managed by the U.S. Department of Veterans Affairs National Cemetery Administration.
- The construction work includes regrading and expanding the in-ground cremain site, replacing existing lighting at the flag pole, constructing new electrical conduit, relocating the POW/MIA flag, and addressing deficiencies with the Union Soldiers' Monument.
- The project has a total of 76 in-ground cremain sites within 4'x4' plots.
- Key drawings include the site layout plan, burial section grading plan, erosion and sediment control plan, demolition plan, and electrical site plan with details.
- The work is to be completed in accordance with Tennessee state construction standards and the VA's requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78624B0024 0002.docx | DOCX document | |
| BD Specs 885CM3015 Knoxville.pdf | ||
| 36C78624B0024 0001.docx | DOCX document | |
| Cost Estimate Worksheet.pdf | ||
| IFB 36C78624B0024_revised.pdf | ||
| P02 885CM3015_Knoxville_BD_Submission_Specs.pdf | ||
| 36C78624B0024_1.docx | DOCX document | |
| P02 885CM3015_Knoxville_BD_Submission_Plans.pdf | ||
| 8 - Cost Estimate Worksheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRAVESITE YIELD SUMMARY
TOTAL NUMBER
OF GRAVESITES
IN-GROUND CREMAIN
SITES (4'x4')
CREMAIN PLOTS
KNOX COUNTY
KNOXVILLE, TENNESSEE
CORRECT CEMETERY FACILITY
CONDITION ASSESSMENT (FCA)
DEFICIENCIES
PROJECT NUMBER: 855CM3015
CONSTRUCTION DOCUMENTS
DRAWING INDEX
SITE/CIVIL
GI001 COVER SHEET
GI002 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
VL101 EXISTING CONDITIONS PLAN
GC101 CONSTRUCTION SEQUENCE PLAN
GC102 EROSION AND SEDIMENT CONTROL PLAN
GC501 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS
CD101 DEMOLITION PLAN
CS101 SITE LAYOUT PLAN
CG101 BURIAL SECTION GRADING ENLARGEMENT PLAN
CS501 SITE DETAILS
CS502 UNION SOLDIERS MONUMENT REPAIR AND MAINTENANCE DETAILS
ELECTRICAL
EL101 ELECTRICAL SITE PLAN
EL102 ELECTRICAL DETAILS
DRAWING DRAWING TITLE
Know what'sbelow.
before you dig.Call
R
KNOXVILLE NATIONAL CEMETERY
PREPARED BY
COVER SHEET
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
T
EGR I TY FEDERA
L
S ERV I C E S
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
GI
-0
.D W
G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GI001
U.S. Department of Veterans Affairs
AutoCAD SHX Text
LOCATION MAP SCALE: 1"=1,000'
AutoCAD SHX Text
VICINITY MAP NTS
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
KNOXVILLE
AutoCAD SHX Text
N. CENTRAL ST.
AutoCAD SHX Text
N. BROADWAY
AutoCAD SHX Text
N. HALL OF FAME DR.
AutoCAD SHX Text
FIFTH AVE.
AutoCAD SHX Text
WOODLAND AVE.
AutoCAD SHX Text
BAXTER AVE.
AutoCAD SHX Text
BERNARD AVE.
AutoCAD SHX Text I-275
AutoCAD SHX Text I-40, I-75
AutoCAD SHX Text
WRAY ST.
AutoCAD SHX Text
TYSON ST.
AutoCAD SHX Text
COOPER ST.
EXISTING PROPOSED
BOUNDARY/RIGHT-OF-WAY LINE
ADJACENT BOUNDARY LINE
EASEMENT LINE
ROAD CENTERLINE
HEADER CURB
CURB & GUTTER
EDGE OF PAVEMENT
CHAIN LINK FENCE
OVERHEAD UTILITY LINE
UNDERGROUND UTILITY LINE
WATER MAIN
BUILDINGS
SIDEWALK
SANITARY SEWER MAIN
STORM SEWER LINE
TREES/SHRUBS
LIMITS OF WORK
INDEX CONTOUR LINE
INTERMEDIATE CONTOUR LINE
SPOT ELEVATIONS
MISCELLANEOUS SIGNS
SITE LIGHT WITH POLE
DRIP LINE OF TREES
REVERSE CURB
543.6
TO BE
REMOVED
TO
REMAIN
BOARD FENCE
8" W/M8" W/M
8" PVC SAN. SEW.
15" HDPE
TRANS.CURB
SOIL BOUNDARY
HbB HgC
WIRE FENCE
EDGE OF GRAVEL
GUARDRAIL
CIVIL LEGEND:
EDGE OF CONCRETE
LP
SANITARY SEWER CLEAN-OUT
SANITARY SEWER MANHOLE
STORM SEWER MANHOLE
STORM SEWER DROP INLET
STORM SEWER CURB INLET
STORM SEWER RIP-RAP
STORM SEWER END SECTION
FIRE HYDRANT
WATER VALVE
WATER METER
MAIL BOX
UTILITY POLE
FEATURE WALL
OVERHEAD COMMUNICATIONS LINE
UNDERGROUND COMMUNICATIONS LINE
BUILDING MOUNTED LIGHT
UTILITY POLE GUY WIRE
SANITARY SEWER FORCE MAIN
8" PVC SAN. SEW.
15" HDPE
EX. CC RBF
CONCRETE MONUMENT/IRON REBAR
TBSCC-TBSIPF
UNDERGROUND GAS LINE
C3
CO
45 0
GS 45 0
TC 45 0
INV
EX.
EX.
X
CO
MB
MONVDH
EX. VDH
ABBREVIATIONS:
HEADSTONE FACE DIRECTION
BURIAL CRYPT PLOTS
GRAVESITE GRID MONUMENT
CONCRETE SECTION MARKER
DRAINAGE FLOW ARROW
DETAIL LABEL
KEYNOTE REFERENCE LABEL
GRANITE SECTION MARKER
F
PRE-PLACED CRYPTS
INTERIOR CRYPT (TYP.)
PERIMETER CRYPT (TYP.)
XX
LIMITS OF GRADING
LIMITS OF CLEARING
XX
XXXXX
WETLANDS
IN-GROUND CREMAIN SITES
FLAG SLEEVES
FLAG POLEF
DETAIL NO.
SHEET REFERENCE
DIRECTION OF TRAFFIC ARROWS
FEATURE WALL
33 32
TEST PIT LOCATION
A AREA OR ARC
AC ACRE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AGE ABOVE GROUND ELECTRIC
AGEC ABOVE GROUND ELECTRIC CONDUIT
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASPH ASPHALT
AST ABOVE-GROUND STORAGE TANK
ATS ACTIVE TREATMENT SYSTEM
AVE AVENUE
AWWA AMERICAN WATER WORKS ASSOCIATION
A/C AIR CONDITIONING
BC BOTTOM OF CURB
BF BASEMENT FLOOR
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VALVE
BITUM BITUMINOUS
BL BASE LINE
BLDG BUILDING
BLVD BOULEVARD
BM BENCHMARK, BASELINE MARKER
BMP BEST MANAGEMENT PRACTICES
BOE BOTTOM OF EXCAVATION
BOV BLOW OFF VALVE
BRG BEARING
BRL BUILDING RESTRICTION LINE
BV BALL VALVE
BW BOTTOM OF WALL
C COEFFICIENT OF RUNOFF
CALC CALCULATE
CB CATCH BASIN OR CHORD BEARING
CC CENTER TO CENTER
CCTV CLOSED CIRCUIT TELEVISION
CD CONSTRUCTION DOCUMENTS, CONTRACT DOCUMENTS OR CHECK DAM
CDW CHILLED DRINKING WATER
CDWR CHILLED DRINKING WATER RETURN
CDWS CHILLED DRINKING WATER SUPPLY
CE CONSTRUCTION ENTRANCE
CEM CEMENT OR CEMETERY
CF CONTRACTOR FURNISHED
CFS CUBIC FEET PER SECOND OR COMPOST FILTER SOCK
CG CURB AND GUTTER
CHD CHORD
CIP CAST IRON PIPE OR CULVERT INLET PROTECTION
CJ CONTRACTION JOINT
CL CENTERLINE, CLASS
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CN CURVE NUMBER
CND CONDUIT
CNR CORNER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATIONS
CONC CONCRETE
COND CONDITION OR CONDENSER
CONF CONFERENCE
CONN CONNECTION
CON CONTAMINATED
CONSTR CONSTRUCTION
CONT CONTINUATION
CONTR CONTRACT OR CONTRACTOR
COR CONTRACTING OFFICER'S REPRESENTATIVE
COTG CLEANOUT TO GRADE
COV COVER OF CUT OFF VALVE
CPv CHANNEL PROTECTION VOLUME
CPPE CONSERVATION PRACTICE PHYSICAL EFFECTS
CPP CORRUGATED PLASTIC PIPE
CRN CROWN
CSB CONCRETE SPLASH BLOCK
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CSS COMMITTAL SERVICE SHELTER
CSP CONCRETE SEWER PIPE
CT COURT
CTR CENTER OR CONTOUR
CTRL CONTROL
CTS COOLING TOWER SUPPLY
CTV CABLE TELEVISION
CV CONTROL VALVE
CW CLOCKWISE OR CONCRETE WASHOUT
CWP COLD WATER PIPING
D DEPTH
DAT DATUM
DB DEED BOOK; DESIGN-BUILD; DRAIN BASIN
DBL DOUBLE
DD DIVERSION DIKE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DESC DESCRIPTION
DET DETAIL
DI DROP INLET
DIA DIAMETER
DIFF DIFFERENCE
DIP DUCTILE IRON PIPE
DIST DISTANCE
DM DROP MANHOLE
DOC DOCUMENT
DOM DOMESTIC
DR DRIVE
DRE DECOMPOSED ROCK ELEVATION
DS DOWNSPOUT
DWG DRAWING
D/W DRIVEWAY
D DELTA
EA EACH
EBL EAST BOUND LANE
EC EDGE OF CONCRETE
ECL EROSION CONTROL LOG
EG EDGE OF GUTTER
EJ EXPANSION JOINT
ELEV ELEVATION
ELEC ELECTRICAL
ENTR ENTRANCE
EOI END OF INFORMATION
EP EDGE OF PAVEMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
E&S EROSION & SEDIMENT
ES END SECTION
ESMT EASEMENT
ETO EARLY TURNOVER
EPT EXTERNAL PIPE THREAD
EQ EQUAL
EW END WALL
EXP EXPANSION
EX EXISTING
EXT EXTERIOR
FAR FLOOR AREA RATIO
FC FACE OF CURB
FD FOUNTAIN DRAIN
FF FIRST FLOOR OR FINISHED FLOOR
FG FINISHED GRADE
FH FIRE HYDRANT
FIN FINISHED
FLR FLOOR
FN FENCE
FP FLOOD PLAIN
FOC FACE OF CURB
FOTG FIELD OFFICE TECHNICAL GUIDE
FOY FOYER
FP FLAG POLE OR FIRE PROTECTION
FPS FEET PER SECOND
FR FROM
FS FILTER SOCK
FT FEET
FWS FLOWER WATERING STATION
G GAS
GAL GALLON
GDR GUARD RAIL
GEN GENERATOR
GFA GROSS FLOOR AREA
GIP GALVANIZED IRON PIPE
GL GROUND LEVEL
GOVT GOVERNMENT
GR GRADE
GR GUARD RAIL
GS GROUND SHOT
H HORIZONTAL
HC HANDICAP
HCP HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE
HDR HEADER
HDWL HEADWALL
HGL HYDRAULIC GRADE LINE
HH HAND HOLE
HLBC HOT LAID BITUMINOUS CONCRETE
HMA MOT-MIX ASPHALT
HP HIGH POINT OR HIGH PRESSURE
HR HAND RAIL
HT HEIGHT
HW HOT WATER
HWSR HOT WATER SUPPLY & RETURN
HWY HIGHWAY
HYD HYDRANT
HYDR HYDRAULIC
I RAINFALL INTENSITY
ID INSIDE DIAMETER
IGC IN-GROUND CRYPT
IN INCH
INV INVERT
IP IRON PIPE OR INLET PROTECTION
IPF IRON PIPE FOUND
IPS IRON PIPE SET
IRR IRRIGATION
IW IRRIGATION WATER
JB JUNCTION BOX
K ONE THOUSAND (KILO)
KWY KEYWAY
L LENGTH
LAT LATERAL
LF LINEAR FEET
LOC LOCATION
LONG LONGITUDE
LOS LINE OF SIGHT
LP LOW POINT OR LOW PRESSURE
LT LIGHT OR LEFT
LL LOWER LEVEL
M MARKER
MAINT MAINTENANCE
MAT MATERIAL
MAX MAXIMUM
MB MAIL BOX
MECH MECHANICAL
MED MEDIUM
MEMO MEMORANDUM
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFG MANUFACTURING
MGT MANAGEMENT
MH MANHOLE
MI MILE
MIN MINIMUM
MISC MISCELLANEOUS
ML MATERIALS LIST
MN MAGNETIC NORTH
MOD MODEL OR MODIFY
MON MONUMENT
MS MEDIAN STRIP
MSL MEAN SEA LEVEL
MTG MEETING
MTL MATERIAL
MULT MULTIPLE
MUNIC MUNICIPAL
N NORTH
N/F NOW OR FORMERLY
NA NOT APPLICABLE
NAT NATURAL
NATL NATIONAL
NBC NATIONAL BUILDING CODE
NBL NORTH BOUND LANE
NCA NATIONAL CEMETERY ADMINISTRATION
NCPS NATIONAL CONSERVATION PRACTICE STANDARDS
NCTCOG NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS
NE NOT EXCEEDING
NFA NET FLOOR AREA
NHCP NATIONAL HANDBOOK OF CONSERVATION PRACTICES
NIC NOT IN CONTRACT
NO NUMBER
NOI NOTICE OF INTENT
NOM NOMINAL
NPDES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
NRCP NON-REINFORCED CONCRETE PIPE
NRCS NATURAL RESOURCES CONSERVATION SERVICE
NTP NOT TO PROCEED
NTS NOT TO SCALE
OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFB ORGANIC FILTER BERM
OFD OVERFLOW DRAIN
OFT ORGANIC FILTER TUBE
OH OVERHANG
OHC OVERHEAD COMMUNICATIONS
OHE OVERHEAD ELECTRIC
OP OUTLET PROTECTION
OS OVER-SIZED
OZ OUNCE
P PERIMETER, RAINFALL DEPTH
PAR PARALLEL
PAT PATTERN
PB PULL BOX
PC POINT OF CURVATURE
PCA PORTLAND CEMENT ASSOCIATION
PCC POINT OF COMPOUND CURVE
PCEP POINT OF CURVE, EDGE OF PAVEMENT
PCT PERCENT
PCTC POINT OF CURVE, TOP OF CURB
PERF PERFORATED
PED PEDESTAL
PG PAGE
PGL POINT OF GRADE LINE
PH PROFILE HOLE
PI POINT OF INTERSECTION
PIC PUBLIC INFORMATION CENTER
PIV POST INDICATOR VALVE
PL PROPERTY LINE
POTW POTABLE WATER
PP POLYPROPYLENE (PLASTIC)
PPC PRE-PLACED CRYPT
PRC POINT OF REVERSE CURVE
PRELIM PRELIMINARY
POTW PUBLICLY-OWNED TREATMENT WORKS
PROP PROPOSED
PSI POUNDS PER SQUARE INCH
PSL PIPE SLEEVE
PT POINT OF TANGENCY
PTS PASSIVE TREATMENT SYSTEM
PV PRIVATE VAULT
PVC POLY VINYL CHLORIDE (PLASTIC PIPE)
PVI POINT OF VERTICAL INTERSECTION
PVMT PAVEMENT
PVT POINT OF VERTICAL TANGENCY
P&P PLAN AND PROFILE
Q FLOW, AMOUNT OF RUNOFF
Qf EXTREME FLOOD VOLUME Qp OVERBANK FLOOD PROTECTION VOLUME
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RISER, RADIUS
RAD RADIANS
RCN RUNOFF CURVE NUMBER
RCP REINFORCED CONCRETE PIPE, REFLECTED CEILING PLAN
RD ROAD, ROOF DRAIN
RDC REDUCER
RE RESIDENT ENGINEER
REP REPAIR
REQ REQUIRED
REV REVISION
REv RECHARGE VOLUME
RGP ROUGH GRADING PLAN
RPA RESOURCE PROTECTION AREA
RR RAILROAD
RTE ROUTE
RT RIGHT
RV RELIEF VALVE
RW RETAINING WALL
R/W RIGHT-OF-WAY
SAN SANITARY
SB SPLASH BLOCK OR SEDIMENT BASIN
SBL SOUTH BOUND LANE
SCF SEDIMENT CONTROL FENCE
SCHED SCHEDULE
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SEC SECTION
SEG SEGMENT
SEL SELECT
SEW SEWER
SF SQUARE FEET OR SILT FENCE
SSF SUPER SILT FENCE
SJ SCORED JOINT
SLV SLEEVE
SM SECTION MARKER
SMH STEAM MANHOLE
SOV SHUT OFF VALVE
SP SITE PLAN
SPEC SPECIFICATION
SPKLR SPRINKLER
SQ SQUARE
SS SANITARY SEWER, STORM SEWER OR STEAM SUPPLY
ST STREET OR SEDIMENT TRAP
STA STATION
STD STANDARD
STE STEAM
STK STACK
STM STORM
SUPT SUPPORT
SURV SURVEY
SVC SERVICE
SWM STORMWATER MANAGEMENT
S/W SIDEWALK
SWPPP STORM WATER POLLUTION PREVENTION PLAN (SWP3)
SWG SEWAGE
Sx CROSS SLOPE
SYM SYMBOL
T TANGENT
T&M TIME AND MATERIALS
TB TEST BORE
TC TOP OF CURB
Tc TIME OF CONCENTRATION
TCEQ TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
TCP TERRA COTTA PIPE, TRAFFIC CONTROL PLAN
TELE TELEPHONE
TH TEST HOLE
TNL TUNNEL
TOB TOP OF BANK
TOC TOP OF CURB
TOP TOP OF PAVEMENT
TOPO TOPOGRAPHY
TP TEST PIT, TELEPHONE POLE, OR TREE PROTECTION
TPDES TEXAS POLLUTANT DISCHARGE ELIMINATION SYSTEM
TW TOP OF WALL
TXDOT TEXAS DEPARTMENT OF TRANSPORTATION
TYP TYPICAL
UD UNDERDRAIN
U/G UNDERGROUND
UGC UNDERGROUND COMMUNICATIONS
UGE UNDERGROUND ELECTRIC
UFC UNIFORM FIRE CODE
UL UPPER LEVEL
UON UNLESS OTHERWISE NOTED
UP UTILITY POLE
USACE U.S. ARMY CORPS OF ENGINEERS
USDA U.S. DEPARTMENT OF AGRICULTURE
UTIL UTILITY
V VERTICAL
VA VETERANS ADMINISTRATION, VIRGINIA
VAR VARIES
VC VERTICAL CURVE
VEL VELOCITY
VERT VERTICAL
VF VERTICAL FOOT
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VOL VOLUME
W WATER, WEST OR WIDE
W/ WITH
W/O WITHOUT
WBL WEST BOUND LANE
WI WROUGHT IRON
WL WATER LINE
WM WATER MAIN OR WATER METER
WO WORK ORDER
WQv WATER QUALITY VOLUME
WSE WATER SURFACE ELEVATION
WT WATER TIGHT
WW WASTE WATER
X-ING CROSSING
YI YARD INLET
YR YEAR
Z SIDE SLOPES
GENERAL NOTES:
1. PROPOSED SITE IMPROVEMENTS FOR 'KNOXVILLE NATIONAL CEMETERY CORRECT CEMETERY FACILITY CONDITION ASSESSMENT (FCA) DEFICIENCIES' INCLUDES, BUT IS NOT
LIMITED TO, REGRADING AND EXPANSION OF IN GROUND CREMAIN SITE CS, REPLACEMENT OF THE EXISTING LIGHTING AT THE EXISTING FLAG POLE LOCATION, CONSTRUCTION OF ELECTRICAL CONDUIT FROM THE EXISTING ADMINISTRATION BUILDING TO THE FLAG POLE AREA, RELOCATION OF THE EXISTING POW/MIA FLAG, AND ADDRESSING THE DEFICIENCIES OF THE UNION SOLDIERS' MONUMENT. THE PROJECT IS LOCATED AT 939 TYSON STREET IN THE CITY OF KNOXVILLE, TENNESSEE.
2. THE TOPOGRAPHIC CONTOUR INTERVAL IS ONE (1) FOOT. TOPOGRAPHIC INFORMATION IS BASED ON A COMBINATION OF A FIELD ON A FIELD SURVEY DATED JUNE 29, 2018 PREPARED BY LOWE ENGINEERS AND PREVIOUS GRADING WORK FROM VA PROJECT 855CM3014 DATED MARCH 1, 2019. VERTICAL DATUM IS REFERENCED TO NAVD88. THE
HORIZONTAL DATUM IS REFERENCED TO NAD 1983 TENNESSEE STATE PLANE.
3. THE SUBJECT PROPERTY IS LOCATED ON F.E.M.A. MAP 47093C0281G DATED AUGUST 5, 2013. NO PORTION OF THIS PROPERTY IS LOCATED WITHIN THE 100-YEAR FLOODPLAIN
AREA (ZONE A).
4. SEE THIS SHEET FOR LEGEND OF SYMBOLS AND ABBREVIATIONS USED HEREIN.
5. BURIAL CEREMONIES WILL BE SCHEDULED THROUGHOUT THE COURSE OF THIS PROJECT. DURING ALL CEREMONIES, WORK SHALL STOP, ESPECIALLY WHEN HEAVY EQUIPMENT ACTIVITY OR NOISE PRODUCING WORK IS BEING DONE. LIGHT WORK ACTIVITY MAY CONTINUE IF IT DOES NOT CREATE NOISE OR DISTRACTIONS TO THE CEREMONY.
COORDINATE DAILY ACTIVITIES WITH THE CEMETERY DIRECTOR OR HIS APPROVED REPRESENTATIVE TO ACCOMMODATE SCHEDULED BURIALS.
6. DUE TO THE SENSITIVE NATURE OF THE CEMETERY SITE, CONTRACTOR SHALL MAINTAIN EACH WORK AREA IN A CLEAN AND ORDERLY APPEARANCE. TRASH AND WASTE MATERIALS SHALL BE STORED IN APPROVED CONTAINERS AND ROUTINELY DISPOSED OF OFF-SITE. CLEANUP SHALL BE REQUIRED AT THE END OF EACH DAY AND/OR MORE
FREQUENTLY AS REQUIRED.
7. AFFECT OF WORK ON PUBLIC ACCESS SHALL BE MINIMAL AND SHALL BE COORDINATED WITH THE CEMETERY DIRECTOR. ANY ALTERED PUBLIC TRAFFIC ROUTES SHALL BE WELL DEFINED WITH PROFESSIONALLY MADE SIGNAGE AND/OR OTHER APPROVED CONVENTIONAL METHODS. CONTRACTOR SHALL PROVIDE TWO SIGNS SIMILAR TO THE CEMETERY'S "PARDON OUR APPEARANCE" SIGNS. SIZE TO BE A MINIMUM OF 4'X5' HIGH MOUNTED ON TWO 4"X4" POSTS, PLACED IN A LOCATION AS DETERMINED BY THE CEMETERY DIRECTOR. TEXT SIZE SHALL BE MAXIMUM SIZE PROPORTIONAL TO WIDTH/HEIGHT OF SIGN. TEXT WILL BE PROVIDED BY CEMETERY DIRECTOR.
8. THERE SHALL BE AT ALL TIMES WHEN WORK IS BEING DONE, A COMPETENT PERSON WHO IS APPRISED OF THE CONDITION AND PROGRESS OF ALL AREAS OF WORK ON SITE.
THIS PERSON SHALL BE ABLE TO SPEAK FOR AND ACT IN THE BEHALF OF THE CONTRACTOR. THEY SHALL BE AWARE AND KNOWLEDGEABLE OF ALL THE SAFETY CONCERNS ON THE JOB SITE. THEY SHALL BE EMPOWERED TO IMMEDIATELY AND EFFECTIVELY MITIGATE THE ACTIONS OF ANY WORKMAN ON SITE.
CONSTRUCTION NOTES:
1. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE CONSTRUCTION DOCUMENTS PRIOR TO CONSTRUCTION AND NOTIFYING THE U.S. DEPARTMENT OF VETERANS AFFAIRS OF ANY CIRCUMSTANCES FOUND WITHIN THESE PLANS IN NEED OF VERIFICATION SO THAT APPROPRIATE REVISIONS CAN BE MADE, IF WARRANTED.
2. DEVELOPMENT OF THE SITE INCLUDING CONSTRUCTION AND MATERIALS SHALL BE IN CONFORMANCE WITH THE U.S. DEPARTMENT OF VETERANS AFFAIRS REQUIREMENTS AND THE TENNESSEE STATE DEPARTMENT OF TRANSPORTATION CONSTRUCTION STANDARDS AND SPECIFICATIONS, WHERE APPLICABLE.
3. THE CONTRACTOR SHALL CONTACT TENNESSEE ONE CALL SYSTEM, INC. AT 1-800-351-111 OR 811 A MINIMUM OF SEVENTY-TWO (72) HOURS PRIOR TO ANY EXCAVATION, DEMOLITION OR OTHER EARTH DISTURBING ACTIVITIES WITHIN AREAS SERVED BY UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE
PRESENCE OF ANY UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION.
4. EXISTING UNDERGROUND UTILITIES SHOWN HEREIN HAVE BEEN LOCATED FROM VISIBLE EVIDENCE AND RECORD DRAWINGS FROM PREVIOUS CEMETERY PROJECTS. THE UTILITIES SHOWN MAY OR MAY NOT REFLECT ALL UNDERGROUND UTILITIES IN SERVICE OR ABANDONED. UTILITIES SHOULD BE VERIFIED BY APPROPRIATE UTILITY COMPANIES PRIOR TO ANY CONSTRUCTION. INTEGRITY FEDERAL SERVICES DOES NOT CERTIFY TO THE LOCATION OR THE EXISTENCE OF EXISTING UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR THE DIGGING OF TEST HOLES PRIOR TO BEGINNING CONSTRUCTION. IF CONDITIONS ARE FOUND IN THE FIELD WHICH ARE MATERIALLY
DIFFERENT FROM THE PLANS, THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER.
5. INTEGRITY FEDERAL SERVICES DOES NOT CERTIFY TO THE SUB-SURFACE CONDITIONS OF THE SITE OR THE LOCATION OF UNDERLYING ROCK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DIGGING OF TEST HOLES TO VERIFY SUB-SURFACE CONDITIONS PRIOR TO BEGINNING ANY CONSTRUCTION.
6. ALL TESTS, STUDIES, ETC., REQUIRED DURING CONSTRUCTION WILL BE CARRIED OUT BY A THIRD PARTY ENGINEERING FIRM AND PAID FOR BY THE CONTRACTOR.
7. ALL PROPOSED GRADES AS SHOWN HEREIN ARE FINISHED GRADE UNLESS OTHERWISE NOTED ON THE PLAN.
8. EROSION AND SEDIMENT CONTROL DEVICES ARE TO BE IN PLACE PRIOR TO ANY CONSTRUCTION. REFER TO EROSION AND SEDIMENT CONTROL PLANS FOR PHASING AND
DETAILS.
9. ALL LAND ON OR OFF-SITE WHICH IS DISTURBED BY CONSTRUCTION AND WHICH IS NOT BUILT UPON OR SURFACED SHALL BE ADEQUATELY STABILIZED TO CONTROL EROSION
AND SEDIMENTATION.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE CONTRACTING OFFICER OF ANY CHANGES OR CONDITIONS ATTACHED TO PERMITS REQUIRED FOR
CONSTRUCTION.
11. THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING TRUCKS AND/OR EQUIPMENT OF MUD AND DEBRIS, PRIOR TO ENTERING PAVED AREAS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS OF MUD AND/OR LAYING DUST AND TO TAKE ALL APPROPRIATE MEASURES NECESSARY TO ENSURE THAT STREETS ARE
KEPT IN A CLEAN AND DUST FREE CONDITION AT ALL TIMES.
12. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY EXISTING CONDITIONS PRIOR TO STARTING CONSTRUCTION ACTIVITIES.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE CONTRACTING OFFICER OF ANY CONDITIONS FOUND IN THE FIELD PRIOR TO STAKEOUT THAT VARY FROM THE APPROVED PLANS OR THAT MAKE CONSTRUCTABILITY IMPOSSIBLE. ANY OBSERVATIONS REGARDING APPARENT INCONSISTENCIES IN THE PLANS SHALL BE BROUGHT TO THE
CONTRACTING OFFICER'S ATTENTION FOR VERIFICATION PRIOR TO STAKEOUT.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PERFORMANCE OF ITS WORK AND THE WORK OF ITS SUBCONTRACTORS. THE VA SHALL NOT HAVE CONTROL OVER, CHARGE OF, OR RESPONSIBILITY FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK.
15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE WORK AREA AT ALL TIMES. TEMPORARY BARRICADES, ROAD CLOSURE SIGNAGE, FENCES AND OTHER WARNING DEVICES SHALL BE USED TO PREVENT PUBLIC ACCESS TO CONSTRUCTION WORK AREAS. VA MAINTENANCE OPERATIONS SHALL NOT BE UNDULY IMPEDED BY THE
CONTRACTOR'S OPERATIONS.
16. THE CONTRACTOR SHALL NOTIFY THE CEMETERY DIRECTOR AND THE CONTRACTING OFFICER TWO DAYS BEFORE ANY DEMOLITION WORK BEGINS. ANY PLANNED INTERRUPTIONS IN SERVICES SHALL BE COORDINATED WITH THE CONTRACTING OFFICER AT LEAST TWO DAYS IN ADVANCE.
17. THE CONTRACTOR SHALL CONFINE HIS EQUIPMENT AND OPERATIONS TO THE LIMITS OF CONSTRUCTION SHOWN. THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR THE
SAFETY AND SECURITY OF ALL MATERIALS AND EQUIPMENT ON SITE.
18. THE CONTRACTOR SHALL USE ONLY APPROVED ROADWAYS FOR CONSTRUCTION AND DELIVERY ACCESS. DAMAGE TO THE EXISTING ROADS SHALL BE REPAIRED AT NO COST
TO THE OWNER.
19. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR OF EXISTING CEMETERY GROUNDS DUE TO CONSTRUCTION ACTIVITY.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
GI
-0
.D W
G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GI002
GENERAL NOTES, SYMBOLS, AND
ABBREVIATIONS
UNION SOLDERS'
MONUMENT
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
G
G
G
G
G
EX. FLOOD LIGHT
EX. FLOOD LIGHT
EX. FLOOD LIGHT
EX. FLOOD LIGHT
APPOROX. LOCN.
OF EX. POW/MIA FLAG
EX.
FLAGPOLE
APPROX. EDGE
OF EXISTING
BURIALS
APPROX. LOCN
OF EX. GRID
MONUMENT
MARKERS
APPROX. LOCN
OF EX. GRID
MONUMENT
MARKERS
PLAQUE
PLAQUE
SIGN
PLAQUE
CONCRETE FLUME
ROCK WALL
EX.
RIGHT-OF-WAY
EX.
RIGHT-OF-WAY
EXISTING CONDITIONS PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
VL
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GRAPHICAL SCALE: 1"=20'
20 10 0 20 40 60
VL101
NOTES:
1. PRIOR TO ANY WORK, CONTRACTOR'S SURVEYOR TO ESTABLISH
SURVEY CONTROL WITH VERTICAL DATUM REFERENCED TO NAVD
88 AND HORIZONTAL DATUM REFERENCED TO NAD 1983
TENNESSEE STATE PLANE. CONTRACTOR'S SURVEYOR SHALL
THEN SURVEY THE 4 EXISTING GRID MONUMENT MARKERS
INDICATED ON THE PLAN LOCATED BETWEEN THE
ADMIN/MAINTENANCE BUILDING AND BURIAL SECTION CS.
RECORDING THE HORIZONTAL COORDINATES OF THE MARKERS
FOR REESTABLISHMENT AFTER COMPLETION OF GRADING.
AutoCAD SHX Text
ADMIN/MAINT BLDG
AutoCAD SHX Text
1-STORY ±1,150 SF
AutoCAD SHX Text
COMMITTAL SHELTER
AutoCAD SHX Text
FFE=917.50
AutoCAD SHX Text
FFE=918.67
AutoCAD SHX Text
FFE=920.67
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
4" PVC @ 0.5%
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
PB
AutoCAD SHX Text
INV. 918.53
AutoCAD SHX Text
CP-4
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
DI
AutoCAD SHX Text N48%%d56'31"E
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text G.V.
AutoCAD SHX Text V
AutoCAD SHX Text
CONCRETE FLUME
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' ROLLBACK CURB (TYP.)
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' CURB & GUTTER
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
UTILITY POLE (TYP.)
AutoCAD SHX Text
36" WHITE OAK
AutoCAD SHX Text
42" WHITE OAK
AutoCAD SHX Text
WRAY STREET
AutoCAD SHX Text
BERNARD AVENUE
AutoCAD SHX Text
50' RIGHT-OF-WAY
AutoCAD SHX Text
TRENCH DRAINS
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TRENCH DRAIN
TYSON STREET
OHE
OHE
OHE
OHE
G
G SAF
SAF
SAF
SAF
TYSON STREET
BERNARD AVENUE
COOPER STREET
UNION SOLDIERS'
MONUMENT
ADMINISTRATION /
MAINTENANCE
FACILITY
COMMITTAL
SERVICE SHELTER
FLAG POLE AREA
OLD GRAY CEMETERY
SAFETY SIGN
LOCATION
SUBJECT TO COR
APPROVAL IN FIELD
CONSTRUCTION SEQUENCE PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
GC
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GRAPHICAL SCALE: 1"=20'
20 10 0 20 40 60
GC101
GENERAL CONSTRUCTION REQUIREMENTS:
BEFORE ANY GENERAL CONSTRUCTION ACTIVITIES MAY COMMENCE, THE CONTRACTOR SHALL:
1. RETAIN A PRIVATE UNDERGROUND LOCATOR SERVICE AT THEIR COST AND HAVE THEM PERFORM THE TRACING AND MARKING OF ALL THE ONSITE BELOW GRADE IMPROVEMENTS WITHIN OR ADJOINING THE CONTRACTOR WORK AREAS FOR THE PROJECT, WALK THE CONSTRUCTION AREAS WITH THE COR AND, IF REQUESTED BY THE COR, ADJUST THE LOCATIONS OF THE NEW WORK AS REQUIRED TO AVOID CONFLICTS, DAMAGE, OR UNINTENDED INTERRUPTIONS OF THE SERVICES BEING PROVIDED BY THE UNDERGROUND FACILITIES. CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL PAINT MARKINGS UPON COMPLETION OF
WORK.
2. OBSERVE AND DOCUMENT THE FUNCTIONALITY OF THE IRRIGATION SYSTEM IN THE VICINITY OF THE CONSTRUCTION AREA. DAMAGED OR NONFUNCTIONAL IRRIGATION SYSTEM EQUIPMENT NOT IDENTIFIED AS BEING DAMAGED OR NON-FUNCTIONAL DURING THE PRE-CONSTRUCTION SURVEY SHALL BE FULLY REPAIRED AND MADE FUNCTIONAL IMMEDIATELY UPON DETECTION OF ANY DAMAGE, AT NO ADDED COST TO THE
OWNER.
3. COMPLETE INSTALLATION OF EROSION AND SEDIMENT CONTROL FOR THE WORK AREAS WHERE WORK WILL BE PERFORMED. INSTALL IMMEDIATELY PRIOR TO THE START OF THE WORK IN ACCORDANCE WITH THE
APPROVED EROSION AND SEDIMENT CONTROL PLAN.
4. THE CONTRACTOR MAY REQUEST USE OF EXISTING MAINTENANCE AREA AND OPEN SPACES THROUGHOUT THE CEMETERY FOR SECONDARY STAGING. USE OF SUCH OPEN AREAS MUST APPROVED BY THE COR AND
MUST BE DETERMINED TO BE OUT OF THE WAY OF DAILY OPERATIONS.
5. TOPSOIL DISTURBED DURING CONSTRUCTION TO BE REPLACED WITH CLEAN TOPSOIL THAT MEETS PLANTING SPEC 32 90 00. BACKFILL CONTAINING CLAY SUBSOIL, ROCKS, PAVEMENT, OR OTHER DEBRIS SHALL NOT BE
PERMITTED.
6. COMPLETE ANY AND ALL OTHER CONTRACTUAL REQUIREMENTS AS IDENTIFIED ELSEWHERE IN THE
CONSTRUCTION DOCUMENTS.
7. ALL CONSTRUCTION ACTIVITIES WILL BE COORDINATED WITH THE NASHVILLE NATIONAL CEMETERY DIRECTOR
AND THE COR.
MAINTENANCE OF TRAFFIC
1. TEMPORARY SIGNAGE IS REQUIRED THROUGHOUT THE PROJECT TO FACILITATE PUBLIC ACCESS TO THE
CEMETERY AND ADVANCE NOTIFICATION OF CONSTRUCTION ACTIVITIES.
2. CONTRACTOR SHALL USE THE PRIMARY CONSTRUCTION ACCESS IDENTIFIED IN THE CONSTRUCTION
DOCUMENTS UNLESS OTHERWISE AUTHORIZED IN ADVANCE BY THE COR.
3. EXISTING ROADWAYS SHALL REMAIN CLEAN AND FREE OF DEBRIS. ALL DEBRIS SHALL BE REMOVED AS IT
OCCURS.
4. CONTRACTOR SHALL MAINTAIN CEMETERY ROADS USED DURING CONSTRUCTION ACTIVITIES THROUGH
REGULAR STREET SWEEPING.
5. CONTROL TRUCK AND EQUIPMENT MOVEMENT SO THEY DO NOT TRANSIT BETWEEN ONGOING SERVICES AT THE COMMITTAL SERVICE SHELTERS. CONTRACTOR SHALL ENSURE THE NOISE FROM TRUCK AND EQUIPMENT TRAFFIC DOES NOT INTERFERE WITH FUNERAL SERVICES AT THE COMMITTAL SERVICE SHELTERS.
SEQUENCE OF CONSTRUCTION:
1. CONTRACTOR TO KEEP ONE LANE/PATH CLEAR FOR CEMETERY OPERATIONS AT ALL TIMES.
2. CONFIRM ALL APPLICABLE LOCAL, STATE AND REGULATORY AGENCY PERMITS.
3. INSTALL TEMPORARY CONSTRUCTION FENCING AND TEMPORARY SIGNAGE. PLACE AND SAFETY SIGN AS
DIRECTED BY COR. SEE DETAILS 4 & 5 ON SHEET CS501 FOR SIGNAGE AND FENCE DETAILS.
4. COMPLETE INSTALLATION OF EROSION AND SEDIMENT CONTROLS FOR THE WORK AREAS WHERE WORK WILL BE PERFORMED. INSTALL IMMEDIATELY PRIOR TO THE START OF THE WORK IN ACCORDANCE WITH THE
APPROVED EROSION AND SEDIMENT CONTROL PLAN.
5. COMPLETE WORK IN AREAS IN THE FOLLOWING ORDER (LIST IS NOT INTENDED TO BE ALL INCLUSIVE):
5.1. COMPLETE GRADING AND SITE IMPROVEMENTS FOR IN-GROUND CREMATION AREA "CS". AREA TO BE
SODDED ONCE EARTHWORK IS COMPLETED.
5.2. INSTALL NEW CONDUIT FROM EXISTING ADMINISTRATION/MAINTENANCE FACILITY TO THE FLAG POLE
AREA.
5.3. REPLACE EXISTING FLOOD LIGHTS WITH NEW LED LIGHTING.
5.4. CONSTRUCT NEW POW/MIA FLAG POLE.
5.5. PLACE STONE BEHIND ADMINISTRATION/MAINTENANCE FACILITY.
6. COMPLETE RENOVATIONS TO THE UNION SOLDIERS' MONUMENT. THIS WORK MAY BE COMPLETED
CONCURRENTLY WITH STEP 5.
LIMITS OF WORK
CONTRACTOR
CONSTRUCTION ACCESS
GRAPHIC LEGEND:
LIMITS OF WORK
LIMITS OF GRADING
CONSTRUCTION SAFETY FENCESAF
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
PB
AutoCAD SHX Text
CP-4
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
DI
AutoCAD SHX Text N48%%d56'31"E
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text G.V.
AutoCAD SHX Text V
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
UTILITY POLE (TYP.)
AutoCAD SHX Text
4"PVC
4"PVC
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
G
G
G
G
G
EX. FLOOD LIGHT
EX. FLOOD LIGHT
EX. FLOOD LIGHT
EX. FLOOD LIGHT
APPOROX. LOCN.
OF EX. POW/MIA FLAG
EX.
FLAGPOLE
APPROX. EDGE
OF EXISTING
BURIALS
APPROX. LOCN
OF EX. GRID
MONUMENT
MARKERS
APPROX. LOCN
OF EX. GRID
MONUMENT
MARKERS
PLAQUE
PLAQUE
SIGN
PLAQUE
CONCRETE FLUME
ROCK WALL
EX.
RIGHT-OF-WAY
EX.
RIGHT-OF-WAY
SF
SF
SF
SF
SF
SF
SF
SF
SAF
SAF
CE
SAF
SAF
SAF
SAF
SA
F
SAF
SAF
SAF
SAF
SFSF SILT FENCE
LIMITS OF WORK
EROSION & SEDIMENT CONTROL LEGEND
SYMBOLKEY DESCRIPTION
LIMITS OF GRADING
DETAIL/PG
SAF CONSTRUCTION SAFETY FENCESAF
CE CONSTRUCTION ENTRANCE
EROSION AND SEDIMENT
CONTROL PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
GC
2.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GRAPHICAL SCALE: 1"=20'
20 10 0 20 40 60
GC102
AutoCAD SHX Text
ADMIN/MAINT BLDG
AutoCAD SHX Text
1-STORY ±1,150 SF
AutoCAD SHX Text
COMMITTAL SHELTER
AutoCAD SHX Text
FFE=917.50
AutoCAD SHX Text
FFE=918.67
AutoCAD SHX Text
FFE=920.67
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
4" PVC @ 0.5%
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
PB
AutoCAD SHX Text
INV. 918.53
AutoCAD SHX Text
CP-4
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
DI
AutoCAD SHX Text N48%%d56'31"E
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text G.V.
AutoCAD SHX Text V
AutoCAD SHX Text
CONCRETE FLUME
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' ROLLBACK CURB (TYP.)
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' CURB & GUTTER
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
UTILITY POLE (TYP.)
AutoCAD SHX Text
36" WHITE OAK
AutoCAD SHX Text
42" WHITE OAK
AutoCAD SHX Text
WRAY STREET
AutoCAD SHX Text
BERNARD AVENUE
AutoCAD SHX Text
50' RIGHT-OF-WAY
AutoCAD SHX Text
TRENCH DRAINS
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TYSON STREET
AutoCAD SHX Text
AutoCAD SHX Text
GC501
AutoCAD SHX Text
AutoCAD SHX Text
GC501
AutoCAD SHX Text
CS501
EROSION AND SEDIMENT
CONTROL NOTES AND DETAILS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
GC
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GC501
NOT TO SCALE
SILT FENCE2
EROSION AND SEDIMENT CONTROL NOTES:
1. ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS AND FILLS SHALL
BE DONE IN ACCORDANCE WITH THE APPROVED E&S PLAN. A COPY OF THE APPROVED DRAWINGS
MUST BE AVAILABLE AT THE PROJECT SITE AT ALL TIMES.
2. AT LEAST 3 FULL BUSINESS DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, OR
EXPANDING INTO AN AREA PREVIOUSLY UNMARKED,TENNESSEE 811 SHALL BE NOTIFIED AT
1-800-351-1111 FOR THE LOCATION OF EXISTING UNDERGROUND UTILITIES.
3. AREAS TO BE FILLED ARE TO BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO REMOVE TREES, VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL
4. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR
ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT
APPROPRIATE BEST MANAGEMENT PRACTICES TO MINIMIZE THE POTENTIAL FOR EROSION AND
SEDIMENT POLLUTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON SITE IS CLEAN
FILL.
6. UNTIL THE SITE IS ESTABLISHED, ALL EROSION AND SEDIMENT BMP'S SHALL BE MAINTAINED PROPERLY.
MAINTENANCE SHALL INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT BMP'S AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, AND REPLACEMENT, IF THE E&S BMP'S FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMP'S OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED,
7. A LOG SHOWING DATES THAT E&S BMP'S WERE INSPECTED AS WELL AS ANY DEFICIENCIES FOUND AND THE DATE THEY WERE CORRECTED SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE AT
THE TIME OF INSPECTION.
8. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED TO THE
CONSTRUCTION SITE BY THE END OF EACH WORK DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO CASE SHALL THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO ANY ROADSIDE
DITCH, STORM SEWER, OR SURFACE WATER.
9. ALL SEDIMENT REMOVED FROM BMP'S SHALL BE DISPOSED OF IN THE MANNER DESCRIBED ON THE
PLAN DRAWINGS.
10. E&S BMP'S SHALL REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS TRIBUTARY TO THEM ARE
PERMANENTLY STABILIZED OR UNTIL THEY ARE REPLACED BY ANOTHER BMP.
11. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE COR SHALL CONDUCT AN INSPECTION PRIOR TO REMOVAL/CONVERSION OF
THE E&S BMP'S
NOT TO SCALE
CONSTRUCTION ENTRANCE1
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
G
G
G
G
G
EX. FLOOD LIGHT
EX. FLOOD LIGHT
EX. FLOOD LIGHT
EX. FLOOD LIGHT
APPOROX. LOCN.
OF EX. POW/MIA FLAG
EX.
FLAGPOLE
APPROX. EDGE
OF EXISTING
BURIALS
APPROX. LOCN
OF EX. GRID
MONUMENT
MARKERS
APPROX. LOCN
OF EX. GRID
MONUMENT
MARKERS
PLAQUE
PLAQUE
SIGN
PLAQUE
CONCRETE FLUME
ROCK WALL
EX.
RIGHT-OF-WAY
EX.
RIGHT-OF-WAY
SAF
SAF
SAF
SAF
SA
F
SAF
SAF
SAF
SAF
DEMOLITION PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
CD
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GRAPHICAL SCALE: 1"=20'
20 10 0 20 40 60
GRAPHIC LEGEND:
LIMITS OF WORK
DEMOLITION NOTES:
1. EXISTING GRID MARKERS, CEMETERY SIGNS, PLAQUES, AND
POW/MIA FLAG ARE TO NOT BE DAMAGED DURING REMOVAL
AS THEY ARE TO BE REUSED.
2. EXISTING ELECTRICAL CONDUIT TO BE ABANDONED IN
PLACE
KEY NOTE LEGEND:
KEY NO. DESCRIPTION
1 SIGNS/PLAQUES TO BE REMOVED AND STORED FOR
REINSTALLATION AFTER CONSTRUCTION
3 REMOVE EXISTING SPOT LIGHT AND DEMOLISH LIGHT
ENCLOSURE. CONCRETE BASE TO REMAIN.
POW/MIA FLAG TO BE REMOVED AND STORED FOR
REINSTALLATION AFTER CONSTRUCTION. CONCRETE
TO BE DEMOLISHED
2 GRID MONUMENT MARKERS TO BE REMOVED AND
STORED FOR REINSTALLATION AFTER CONSTRUCTION
CD101
CONSTRUCTION SAFETY FENCESAF SAF
AutoCAD SHX Text
ADMIN/MAINT BLDG
AutoCAD SHX Text
1-STORY ±1,150 SF
AutoCAD SHX Text
COMMITTAL SHELTER
AutoCAD SHX Text
FFE=917.50
AutoCAD SHX Text
FFE=918.67
AutoCAD SHX Text
FFE=920.67
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
4" PVC @ 0.5%
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
PB
AutoCAD SHX Text
INV. 918.53
AutoCAD SHX Text
CP-4
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
DI
AutoCAD SHX Text N48%%d56'31"E
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text G.V.
AutoCAD SHX Text V
AutoCAD SHX Text
CONCRETE FLUME
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' ROLLBACK CURB (TYP.)
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' CURB & GUTTER
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
UTILITY POLE (TYP.)
AutoCAD SHX Text
36" WHITE OAK
AutoCAD SHX Text
42" WHITE OAK
AutoCAD SHX Text
WRAY STREET
AutoCAD SHX Text
BERNARD AVENUE
AutoCAD SHX Text
50' RIGHT-OF-WAY
AutoCAD SHX Text
TRENCH DRAINS
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TRENCH DRAIN
TYSON STREET
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
G
G
G
G
G
EX.
FLAGPOLE
PLAQUE
CONCRETE FLUME
ROCK WALL
EX.
RIGHT-OF-WAY
EX.
RIGHT-OF-WAY
SAF
SAF
SAF
SAF
SA
F
SAF
SAF
SAF
SAF
SEC
SECTION CS
76 IN-GROUND
CREMAIN PLOTS
(WITHIN 4'X4' PLOTS)
SITE LAYOUT PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
CS
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GRAPHICAL SCALE: 1"=20'
20 10 0 20 40 60
GRAPHIC LEGEND:
LIMITS OF WORK
KEY NOTE LEGEND:
KEY NO. DESCRIPTION
1 REINSTALL EXISTING SIGN AND PLAQUES THAT WERE
PREVIOUSLY REMOVED, ADJUST TO NEW GRADE.
PLACE GRAVEL BETWEEN EXISTING CONCRETE FLUME
AND RETAINING WALL, EXCAVATE EXISTING SOIL IF
NEEDED TO ACCOMODATE THICKNESS OF GRAVEL.
NEW GRAVEL TO MATCH EXISTING GRAVEL FOUND
THROUGHOUT THE CEMETERY.
CONSTRUCT FLAGPOLE AND BASE FOR POW/MIA FLAG.
LOCATION TO BE STAKED IN FIELD BY CONTRACTOR
FOR APPROVAL BY COR PRIOR TO CONSTRUCTION
REINSTALL GRAVESITE GRID MONUMENTS AT SAME
HORIZONTAL COORDINATES AS PREVIOUS, ADJUST TO
NEW GRADE.
INSTALL NEW LED SPOTLIGHTS ON EXISTING
CONCRETE PADS. SEE ELECTRICAL PLANS FOR
SPOTLIGHT DETAILS
3 INSTALL BURIAL SECTION MARKER.
DETAIL
CS101
LIMITS OF GRADING
IN-GROUND CREMAIN PLOTS
NOTES:
1. CONTRACTOR TO EXCAVATE AND HAUL AWAY 3' OF SOIL IN THE IN-GROUND
CREMAINS AREA TO DISPOSE OF DEBRIS LEFT FROM PREVIOUS
CONSTRUCTION ACTIVITIES.
2. ELECTRICAL LAYOUT FOR FLAG POLE LIGHTING TO BE COORDINATED WITH
ELECTRICAL PLANS.
3. EXISTING CONCRETE PADS FOR SPOTLIGHTS
3.1. CLEAN AND SEAL CRACKS AND OPENINGS IN CONCRETE SLAB.
3.2. APPLY BONDING AGENT TO CONCRETE SURFACE PRIOR TO INSTALLING
2" CONCRETE TOPPING.
3.3. PROVIDE LIGHT BROOM FINISH.
4. CONTRACTOR TO REPLACE GRID MONUMENTS, SIGNS, AND PLAQUES TO
THEIR ORIGINAL POSITIONS. LOCATIONS ON PLAN ARE APPROXIMATE AND
ARE TO BE VERIFIED BY THE CONTRACTOR IN THE FIELD.
5. ALL AREAS OF DISTURBANCE TO BE PLANTED WITH TURF SOD. SEE
PLANTING SPECIFICATION 32 90 00 FOR ADDITIONAL INFORMATION.
CONSTRUCTION SAFETY FENCESAF SAF
LIMITS OF GRAVEL INSTILLATION
AutoCAD SHX Text
ADMIN/MAINT BLDG
AutoCAD SHX Text
1-STORY ±1,150 SF
AutoCAD SHX Text
COMMITTAL SHELTER
AutoCAD SHX Text
FFE=917.50
AutoCAD SHX Text
FFE=918.67
AutoCAD SHX Text
FFE=920.67
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
4" PVC @ 0.5%
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
PB
AutoCAD SHX Text
INV. 918.53
AutoCAD SHX Text
CP-4
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
DI
AutoCAD SHX Text N48%%d56'31"E
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text G.V.
AutoCAD SHX Text V
AutoCAD SHX Text
CONCRETE FLUME
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' ROLLBACK CURB (TYP.)
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
2' CURB & GUTTER
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
UTILITY POLE (TYP.)
AutoCAD SHX Text
36" WHITE OAK
AutoCAD SHX Text
42" WHITE OAK
AutoCAD SHX Text
WRAY STREET
AutoCAD SHX Text
BERNARD AVENUE
AutoCAD SHX Text
50' RIGHT-OF-WAY
AutoCAD SHX Text
TRENCH DRAINS
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
4"PVC
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TYSON STREET
AutoCAD SHX Text
AutoCAD SHX Text
CS501
AutoCAD SHX Text
AutoCAD SHX Text
CS501
AutoCAD SHX Text
AutoCAD SHX Text
CS501
AutoCAD SHX Text
CS501
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
G G
G G
G
G
SE
C
211822 56
922 921
.0%
.9%
8.7
9.5
9.6
9.2 % 9.6
11.0%
9.5
.0%
5.7%1.1% 1.1%
FG: 925.30
FG: 925.14
FG: 927.00
FG: 927.45 FG: 927.25
FG: 922.40 FG: 922.28
FG: 922.07
SA
F
SA
F
SAF SAF
SA
F
SAF SAF SAF
SA
F
SA
F
SA
F
SA
F
SA
F
SAF
SAF
SAF
SAF
SAF
SAF
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34 35 36 37 38 39 40 41 42
43 44 45 46 47 48 49 50 51 52 53 54 55 56
57 58 59 60 61 62 63 64 65 66 67 68 69 70
71 72 73 74 75 76
SECTION CS
76 IN-GROUND
CREMAIN PLOTS
(WITHIN 4'X4' PLOTS)
ELEVATION LABEL
FINISHED GRADE ELEVATIONFG
EXISTING CONTOUR (5' INTERVAL)
EXISTING CONTOUR (1' INTERVAL)
PROPOSED CONTOUR (5' INTERVAL)
PROPOSED CONTOUR (1' INTERVAL)
LEGEND:
HEADSTONE FACE DIRECTION
GRAVESITE GRID MONUMENT
IN-GROUND CREMAINS SITES
SAF CONSTRUCTION SAFETY FENCE
LIMITS OF GRADING
LIMITS OF WORK
BURIAL SECTION GRADING
ENLARGEMENT PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
CG
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
GRAPHICAL SCALE: 1"=10'
10 5 0 10 20 30
CG101
NOTES:
1. PLOT NUMBERS TO VARY BASED ON EXISTING CS SECTION
NUMBERING.
2. GRAVESITE GRID MONUMENTS TO BE REINSTALLED AT SAME
HORIZONTAL COORDINATES AS PREVIOUS, ADJUST TO NEW
GRADE.
AutoCAD SHX Text
ADMIN/MAINT BLDG
AutoCAD SHX Text
FFE=920.67
AutoCAD SHX Text
4" PVC @ 0.5%
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
4" PVC UNDERDRAIN
AutoCAD SHX Text
INV. 918.53
FG 141.53
2"
3'- 6"
MI
N.
D
EP
TH
NOTES:
1. ALL LAWNS AND IRRIGATION LINES WITHIN THE BURIAL SECTIONS SHALL BE INSTALLED AND ACCEPTED PRIOR TO MONUMENT-BASE
PLACEMENT; ALL LAWNS DAMAGED DURING INSTALLATION SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE.
2. AT THE CONTRACTOR'S OPTION, GRAVESITE GRID MONUMENTS MAY BE PROVIDED AS CAST IN-PLACE UNITS. PROVIDE SHOP DRAWINGS
AND METHOD OF INSTALLATION FOR APPROVAL.
3. FINISH GRADE IS TOP OF DECOMPOSED GRANITE.
4. DETAIL IS PROVIDED AS A REFERENCE FOR REINSTATEMENT PURPOSES.
3"
MONUMENT MARKER (PROTECT VISIBLE SURFACES DURING PLACEMENT INTO CONCRETE)
3-1/2"Ø FORGED ALUMINUM DOMED-TOP MONUMENT MARKER WITH 3/4" DIAMETER SPLIT STYLE STEM
AND INTEGRAL LOCATION MAGNET EMBEDDED
SET TOP OF MONUMENT 1/2" ABOVE FINISHED GRADE
GAP AROUND CYLINDER & SURROUNDING EARTH SHALL BE FILLED W/ CONCRETE OR REDI-CRETE
(WETTED AFTER PLACEMENT) TO WITHIN 4" OF FINISH GRADE
8"Ø CONCRETE MONUMENT BASE; 3,500 PSI @ 28 DAYS
COMPACTED APPROVED FILL OR NATIVE EARTH
SMOOTH-TROWEL FINISH TOP SURFACE, ENSURING POSITIVE DRAINAGE.
G R
A
V
E
S ITE GR I D MON
UM
E
N T
N
A T IO
NA L CEM E T ER Y
PLAN VIEW
MONUMENT MARKER (SEE DETAIL)
G
RA
VES I TE GR I D MONUM
EN
T
NA
T
I ONA L C EME T E RY
CROSS HAIRS MUST FALL WITHIN 3/4" OF
THE CENTER OF THE MARKER OR THE
ENTIRE MONUMENT MUST BE MOVED
EDGE OF MONUMENT MARKER SHALL BE NO
CLOSER THAN 1" TO OUTSIDE EDGE OF CONCRETE
CONCRETE BASE
1" MIN.
3-1/2"Ø FORGED ALUMINUM DOMED-TOP MONUMENT
MARKER WITH 3/4" DIAMETER SPLIT STYLE STEM AND
INTEGRAL LOCATION MAGNET EMBEDDED
FIELD INCISED HAIRS ON CAP; CROSS-HAIRS SHALL
BE PARALLEL AND PERPENDICULAR TO THE
GRAVESITE GRIDLINES & PRECISE TO ±0.005'
REQUIRED TEXT ENGRAVED ON CAP, TYP.
2'- 0"
2'- 0"
NOTES:
SIZE:
OVERALL SIGN DIMENSIONS: 2'-0" HIGH x 6" WIDE x 6" DEPTH SIGN FACE: 8" LONG x 6" WIDE
DESCRIPTION:
LIGHT GRAY GRANITE SECTION MARKER: HONED SMOOTH INSCRIPTION FACE, ALL OTHER SURFACES TO BE
SMOOTH SAW-CUT FINISH.
ALL CORNERS AND EDGES INCLUDING 2" BELOW GROUND LEVEL SHALL BE ROUNDED TO 3/8" RADIUS
GRAPHIC PROCESS:
"SEC" SHALL BE ENGRAVED LETTERS: 1-1/2" HT., 3/16" DEPTH, 3/16" STEMS & BARS; TEXT FOR SECTION I.D.
NUMBERS SHALL BE AS SHOWN ON PLAN, APPROVED BY THE VA & BE ENGRAVED: 2" HT., 3/16" DEPTH, 3/8"
STEMS & BARS; ALL TEXT TO BE HELVETICA MEDIUM FONT.
RECOMMENDATIONS:
POSITION SIGN TO PROVIDE PEDESTRIANS WITH A CLEAR, UNOBSTRUCTED VIEW OF THE SIGN.
7"
6"6"
2"
8"
2- 14 "
6- 12 "2"
10' (TYP.) TO
BACK OF CURB
SEC
1- 12 "
GROUND LEVEL2"
4'
3' 3'
11 2" 11 2" 11 2"
9" 4"
ALL VISIBLE SURFACES
TO BE PRIMED AND PAINTED
SIGN ATTACHED TOGETHER
WITH WOOD SCREWS & LAG BOLTS
CHANGEABLE NUMBERS
3 4"
3' M
IN
FINISHED GRADE (TYP.) FINISHED GRADE (TYP.)
SIZE:
SIGN PANEL: 3' HIGH x 4' WIDE
DESCRIPTION:
SIGN USED IN CONSTRUCTION SITES TO PROVIDE
INFORMATION REGARDING FREQUENCY OF ON SITE
CONSTRUCTION RELATED ACCIDENTS. SIGN PANEL
IS BUILT WITH A REGION TO DISPLAY CHANGEABLE
NUMBERS TO INDICATE THE NUMBER OF DAYS
SINCE TIME WAS LOST DUE TO A CONSTRUCTION
ACCIDENT.
MESSAGE CONFIGURATION:
REFER TO MESSAGE LAYOUT DETAIL FOR
DIMENSIONS.
SIGN COMPONENTS:
POSTS (METAL OR WOOD) AND MEDIUM DENSITY
OVERLAY (M.D.O.) PLYWOOD OR ALUMINUM SIGN
PANEL. SIGN PANEL MAY OR MAY NOT BE FRAMED.
SIGN PANEL IS EQUIPPED WITH A REGION TO
DISPLAY CHANGEABLE NUMBERS.
GRAPHICS PROCESS:
SURFACE APPLIED VINYL OR SCREENED GRAPHICS.
COLORS:
FOR BACKGROUND, TYPE AND GRAPHIC COLORS,
REFER TO COLOR CHART IN THE VA SIGNAGE
DESIGN MANUAL "SECTION 12: NATIONAL CEMETERY
SIGNS"
TYPOGRAPHY:
HELVETICA BOLD.
MOUNTING:
POST MOUNTED SIGN PANEL.
INSTALLATION:
IT IS RECOMMENDED THAT THIS SIGN BE PLACED AT
A VISIBLE LOCATION ON A CONSTRUCTION SITE
NEAR A FIELD OFFICE.
FACE PANEL TO BE AN EXTERIOR GRADE M.D.O. SHEET
OR AN ALUMINUM SKIN LAMINATED TO A WOOD OR
PLASTIC CORE IS PREFERRED WITH EDGES PHYSICALLY
SEALED.
PLAN VIEW
4"x4" POSTS
4"
3' M
IN
END VIEWELEVATION
4"x4" POSTS
2"x4" FRAMING
2"x4" FRAMING 4"x4" POSTS (TYP.)
FACE
General Contractor's Firm Name
"G " M
IN
"H " M
IN
"F"
MIN. DIA.
"D"
"E"
"A" MIN. DIA.
"C"
"B"
PER MANUFACTURER
NOTES:
THE UNDEREXPOSED SURFACE OF THE FLAGPOLE
(BELOW GRADE) SHALL RECEIVE A HEAVY COAT OF
BLACK ASPHALTIC PAINT INSIDE AND OUT BEFORE
SHIPMENT
POLE MATERIAL:
FLAGPOLE SHALL BE MADE FROM 6063-T6 ALLOY
SEAMLESS COLD DRAWN EXTRUDED ALUMINUM
TUBING
POLE FINISH: CLEAR ANODIZED
FLAG SIZE BASIS OF DESIGN 3'X5'.SERVICE EMBLEM,
FLAGS GOVERNMENT PROVIDED.
BASIS OF DESIGN: 25' HT. POLE, EDER FLAG MODEL
EC25IH DELUXE IH SERIES WITH 'M' WINCH.
EX
PO
SE
D
HE
IG
HT
ANODIZED ALUMINUM FINAL BALL
(SEE SPECS.)
CONE STYLE, REVOLVING, INTERNAL
HALYARD TRUCK (SEE SPECS)
FLAG (N.I.C.) - PROVIDED BY OWNER,
INSTALLED BY CONTRACTOR
COVERED COUNTERWEIGHT & NYLON
BEADED RETAINER (SEE SPECS);
LOOP WITH NICKEL PLATED SNAP
HOOKS
WINCH
ASSEMBLY
FINISH
GRADE
FLAGPOLE (SEE SPECIFICATIONS)
SILICONE SEALANT AROUND FLASHING COLLAR
ALUMINUM FLASHING COLLAR
WATERPROOF CEMENT SEALANT 2" MIN. DEPTH
PACKED DRY SAND
1/16" (16 GA.) GALV. CORRUG. STEEL SLEEVE EXTENDED UP
TO FINISH GRADE
3500 PSI MIN. CONCRETE
4 STEEL WEDGES WELDED TO STEEL PLATE
WELDED STEEL BASE PLATE
6" SQUARE STEEL SUPPORT PLATE WELDED TO SPIKE
3/4" Ø x (MIN. 6" BELOW CONC.) ATTACH LIGHTNING KIT TO ROD
WELDED TO PLATES
LIGHTNING KIT COPPER WIRE PER MANUFACTURER
EXISTING
COMPACTED
SUBGRADE
SITE DETAILS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
KNOXVILLE, TENNESSEE
855CM3015
MARCH 21, 2024 DCW RJP
Office of Design and
Construction
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
KNOXVILLE NATIONAL CEMETERY
CORRECT CEMETERY FACILITY CONDITION
ASSESSMENT (FCA) DEFICIENCIES
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\50
-0
1 N
CA
K
NO
XV
ILL
E
FC
A\
EN
GI
N\
PL
AN
S\
CS
1.D
W G
INTEGRITY
FEDERAL SERVICES
CIVIL ENGINEERING ● LANDSCAPE ARCHITECTURE ● PLANNING
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.ifs-ae.com
IN
TE
GRI TY FEDERAL
SERV I CE S
Holt Engineering & Consulting
(208) 615-9576
NOT TO SCALE
GRAVESITE GRID MONUMENT1 NOT TO SCALE
MONUMENT MARKER2 NOT TO SCALE
GRANITE SECTION MARKER3
CS501
NOT TO SCALE
CONSTRUCTION SIGN: SAFETY (SP-24.04)4
MI
NI
MU
M)
TEMPORARY CONSTRUCTION FENCE NOTES:
1. BEFORE CONSTRUCTION OPERATIONS BEGIN, THE CONTRACTOR SHALL PROVIDE A CHAIN LINK CONSTRUCTION FENCE, SEVEN FEET MINIMUM HEIGHT, AROUND AREAS OF ACTIVE CONSTRUCTION. THE TEMPORARY FENCING SHALL ENCOMPASS THE CONSTRUCTION WORK AREA(S) TO SERVE AS
A PEDESTRIAN BARRIER TO ALERT VA PATRONS OF THE CONSTRUCTION SITE.
2. THE CONSTRUCTION FENCE SHALL BE PROVIDED WITH PRIVACY SCREENING MATERIALS TO PRODUCE A VISUAL BARRIER TO THE PUBLIC FROM THE ADJOINING BUILDINGS INTO THE CONTRACTOR WORK AREAS. THE VISUAL BARRIER SHALL ACCOMMODATE WIND LOADING WITHOUT CAUSING THE
FENCE TO BEND OR FALL OVER.
3. PROVIDE GATES AS REQUIRED FOR ACCESS WITH NECESSARY HARDWARE, INCLUDING HASPS AND PADLOCKS.
4. FASTEN FENCE FABRIC TO TERMINAL POSTS WITH TENSION BANDS AND TO LINE POSTS AND TOP AND BOTTOM RAILS WITH TIE WIRES SPACED AT
MAXIMUM 15 INCHES.
5. BOTTOM OF FENCES SHALL EXTEND TO ONE INCH ABOVE GRADE. REMOVE THE FENCE WHEN DIRECTED BY RE/COR.
6. DETAIL PROVIDED IS FOR ILLUSTRATIVE PURPOSES ONLY. FENCING WITH EQUIVALENT FORM/FUNCTION SHALL BE SUBMITTED AND CONSIDERED FOR
APPROVAL.
BOTTOM OF FENCE
TO 1" ABOVE GRADE
NOTCHED & WELDED NOTCHED & WELDEDWIRE TIES
MA
XI
MU
M)
MA
XI
MU
M) GALVANIZED STEEL
TUBE
FASTEN FENCE FABRIC AT TERMINAL
POSTS WITH TENSION BANDS
SPACED AT MAXIMUM 15 INCHES.
FASTEN FENCE FABRIC TO
TOP/BOTTOM RAILS & LINE POSTS
WITH TIE WIRES SPACED AT
MAXIMUM 15 INCHES.
GALVANIZED STEEL
TUBE
STEEL FEET, BLOCKS OR OTHER
ACCEPTABLE MEANS OF SUPPORT
NOT TO SCALE
TEMP…
This is the start of the file's text. The full file is on GovTribe.