LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 4 of 6.pdf

PDF 8 MB Posted

Attached to
Y1EB--Los Angeles CA 898 -034 Maint, 036 FCA (VA-24-00060981)
Solicitation number
36C78624B0023
Issued by

About this file

This document appears to be a set of design drawings and exhibits for a federal contract opportunity related to correcting FCA (Facility Condition Assessment) deficiencies at the Los Angeles National Cemetery. The key details include:

The project involves historic preservation, rehabilitation, and repairs to various buildings and monuments within the cemetery, including the 3rd Infantry Division Memorial, the Spanish American Monument, and the front entry gate. The work includes installing privacy fencing around water valves, constructing a dumpster and spoils area, repairing the historic front entry, and installing ornamental and chain link fencing in various areas of the cemetery. The project includes several bid options, such as Option 4 for additional historic preservation work. The design drawings provide detailed plans, elevations, and construction details for the required work. The solicitation number is 36C78624B0023, the contract is being issued by the Department of Veterans Affairs National Cemetery Administration, and the performance period is September 8, 2023.

View the file

Other files

File Type Posted
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 5 of 6.pdf PDF
RFIs -AE-COR.docx DOCX document
Amendment 0002.docx DOCX document
LANC Combined Specifications 4 of 4 Rev 001 6.20.24.pdf PDF
LANC Combined Specifications 3 of 4 Rev 001 6.20.24.pdf PDF
LANC Combined Specifications 2 of 4 Rev 001 6.20.24.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 2 of 6.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 1 of 6.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 3 of 6.pdf PDF
LANC Combined Specifications 1 of 4 Rev 001 6.20.24.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 6 of 6.pdf PDF
S04 LA Sign In Roster.pdf PDF
S01 LA 0001 Amendment.docx DOCX document
36C78624B0023.docx DOCX document
231030 LANC 898-Multi MX - FCA IFB Scope of Work.docx DOCX document
S02 Final LANC Combined Specifications -4 of 4.pdf PDF
231030 LANC 898-036 FCA Bid Docs 5 of 5.pdf PDF
231030 LANC 898-036 FCA Bid Docs 4 of 5.pdf PDF
231030 LANC 898-034 MX Bid Docs 3 of 5.pdf PDF
231030 LANC 898-036 FCA Bid Docs 2 of 5.pdf PDF
S02 Final LANC Combined Specifications-1 of 4.pdf PDF
P07 Wage Determination LA.pdf PDF
231030 LANC 898-036 FCA Bid Docs 3 of 5.pdf PDF
36C78624B0023_2.docx DOCX document
231030 LANC 898-034 MX Bid Docs 5 of 5.pdf PDF
231030 LANC 898-034 MX Bid Docs 4 of 5.pdf PDF
231030 LANC 898-036 FCA Bid Docs 1 of 5.pdf PDF
S02 Final LANC Combined Specifications -3 of 4.pdf PDF
S02 Final LANC Combined Specifications-2 of 4.pdf PDF
231030 LANC 898-034 MX Bid Docs 1 of 5.pdf PDF
231030 LANC 898-034 MX Bid Docs 2 of 5.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

HISTORIC PRESERVATION (BASE BID)

C-201

VICINITY MAP

NOT TO SCALE

AOI D2

SCALE: NTS

BUILDING 5705 (IN MEMORY OF SECTION MARKER)D2

SCALE: NTS

BUILDING HA-1 (3RD INFANTRY DIVISION)B8

SCALE: NTS

BUILDING HA-11 (DE GEEST OVERWINT)D8

GENERAL NOTES:

1. CONTRACTOR SHALL REPAIR/REHABILITATE ALL ITEMS

SHOWN PER THE HISTORIC PRESERVATION REPORT.

AOI B8 & D8

AOI D5

SCALE: NTS

SPANISH AMERICAN MONUMENTD5

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

AutoCAD SHX Text 382.31

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

HISTORIC PRESERVATION (BID OPTION

4)

C-202

VICINITY MAP

NOT TO SCALE

SCALE: NTS

BUILDING HA-8 (CANNON)C5

SCALE: NTS

CAISSONF5

GENERAL NOTES:

1. CONTRACTOR SHALL REPAIR/REHABILITATE ALL ITEMS

SHOWN PER THE HISTORIC PRESERVATION REPORT.

2. CAISSON IS CURRENTLY LOCATED ON CEMETERY

PROPERTY AND ONCE PRESERVED SHALL BE PLACED

PER NCA DIRECTION.

AOI C5

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

36" DIA EUC

36" DIA EUC

29"39"39"

24"

5.48'

1.76'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - PRIVACY

FENCING AT WATER VALVES (BASE BID)

C-401

0 10 20

1 INCH = 10 FEET

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

STORAGE BINS

FRONT ENTRY GATE

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE WALL

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

COMPOSITE FENCE W/ CURBINGVICINITY MAP

NOT TO SCALE

KEYED NOTES

1. 6' CHAIN LINK FENCING WITH PRIVACY SLATS AND MOW

CURB, SEE DETAIL B2/C-504.

2. 8' WIDE CHAIN LINK GATE WITH PRIVACY FENCING

D2/C-504.

3. INSTALL AGGREGATE BASE WITHIN FENCED AREAS, SEE

DETAIL F2/C-504

AOI

VETERAN AVE

SCALE: NTS

WATER VALVES FACING NORTHEASTE2 SCALE: NTS

WATER VALVES FACING EASTE5 SCALE: NTS

WATER VALVES FACING SOUTHWESTE8

EXISTING ORNAMENTAL FENCING

TREE PROTECTION NOTES:

1. EXCAVATION OR GRADING WITHIN THE DRIP LINE OF

ANY TREE MUST UTILIZE ALTERNATIVE METHODS SUCH

AS HAND DIGGING TO LOCATE ROOTS.

2. TREE PROTECTION FENCING SHALL BE INSTALLED

AROUND ALL TREES THAT HAVE A DRIP LINE WITHIN

THE LIMITS OF DISTURBANCE FOR CONSTRUCTION

ACTIVITIES OTHER THAN ASPHALT PAVING AND SHALL

EXTEND A MINIMUM OF 10' FROM THE TRUNK OR THE

DRIP LINE OF THE TREE, WHICHEVER IS GREATER.

(TYP)

3. THE CUTTING OF ROOTS GREATER THAN ONE (1) INCH

DIAMETER MUST BE APPROVED AND SUPERVISED BY A

LICENSED ARBORIST.

4. CONTRACTOR SHALL PRESERVE AND PROTECT ALL

TREES FROM DAMAGE BY DEMOLITION OPERATIONS.

ANY TREE DAMAGED BY CONSTRUCTION OPERATIONS

SHALL BE REPLACED WITH A TREE OF THE SAME

SPECIES AND SIZE. IF SIZE IS NOT AVAILABLE

CONTRACTOR SHALL REPLACE WITH A 2" CAL. TREE

(DECIDUOUS) OR 6' HEIGHT TREE (EVERGREENS) AND

SHALL PROVIDE A CREDIT TO THE OWNER FOR THE

MONETARY DIFFERENCE IN VALUE.

5. SHOULD CONFLICTS BETWEEN THE PROPOSED

CURBING AND EXISTING TREES EXIST, THE

CONTRACTOR SHALL NOT INSTALL CURBING IN THE

CONFLICT AREA SEE DETAIL D2/C-502.

5.1. FOR ALL CURBING NOT INSTALLED, THE

CONTRACTOR SHALL PROVIDE THE GOVERNMENT

A CREDIT PER LINEAR FOOT NOT INSTALLED.

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text

IRB

AutoCAD SHX Text

IRB

AutoCAD SHX Text

IRB

AutoCAD SHX Text

IRB

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

36" DIA EUCALYPTUS

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

10"

27"

8"

13"

24"

15"

8" 18"

6"

7"

7" 6" 12"

8"

7"

14" 28" 8"

14"

14"

14"

18"

29" 23"

8"

15"

13"

6"

7"

8" 8"

7"36"

48"

7"

6"

8"

36"

8"

16"

6"

16"6"

16"

17"

18"

24"

18"

6"

28"

14"

15" 37"

11"

21"

15"

17" 16" 12"

14" 16"

18"

16"

40"

27"24"

34"

6"

31"

48"

23"

31"

22"

22"

36" DIA.

18.00'

33.46'

17.58'±

94.00'

22.00'

15.00'

30.00'

40.00'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - DUMPSTER AND

SPOILS AREA (BASE BID)

C-402

0 20 40

1 INCH = 20 FEET

KEYED NOTES

1. CONCRETE STORAGE BINS, SEE SHEET C-510.

2. CONCRETE PAVING, SEE DETAIL B5/C-501.

3. ASPHALT PAVING, SEE DETAIL B2/C-501.

4. BOLLARD, SEE DETAIL B5/C-502.

5. 25' X 100' PREFABRICATED METAL ROOF OVER STORAGE

BINS, SEE SHEET C-512.

6. NOT USED.

7. 6" PERFORATED PVC.

8. 10" SOLID PVC.

9. TAPERED END SECTION, SEE DETAIL C6/C-502.

10. 10' CHAIN LINK FENCING W/ PRIVACY SLATS, SEE DETAIL

SHEET C-504.

11. CONCRETE BUMPER CURB, SEE DETAIL THIS SHEET.

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE STORAGE BINS

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

VICINITY MAP

NOT TO SCALE

AOI

VETERAN AVE

PREFABRICATED METAL ROOF NOTES:

1. ROOF SHALL BE SINGLE PITCH SLOPING FROM FRONT

TO BACK.

2. ROOF STRUCTURE SHALL NOT HAVE WALLS.

CONTROL JOINT

EXPANSION JOINT

TREE PROTECTION NOTES:

1. EXCAVATION OR GRADING WITHIN THE DRIP LINE OF

ANY TREE MUST UTILIZE ALTERNATIVE METHODS SUCH

AS HAND DIGGING TO LOCATE ROOTS.

2. TREE PROTECTION FENCING SHALL BE INSTALLED

AROUND ALL TREES THAT HAVE A DRIP LINE WITHIN

THE LIMITS OF DISTURBANCE FOR CONSTRUCTION

ACTIVITIES OTHER THAN ASPHALT PAVING AND SHALL

EXTEND A MINIMUM OF 10' FROM THE TRUNK OR THE

DRIP LINE OF THE TREE, WHICHEVER IS GREATER.

(TYP)

3. THE CUTTING OF ROOTS GREATER THAN ONE (1) INCH

DIAMETER MUST BE APPROVED AND SUPERVISED BY A

LICENSED ARBORIST.

4. CONTRACTOR SHALL PRESERVE AND PROTECT ALL

TREES FROM DAMAGE BY DEMOLITION OPERATIONS.

ANY TREE DAMAGED BY CONSTRUCTION OPERATIONS

SHALL BE REPLACED WITH A TREE OF THE SAME

SPECIES AND SIZE. IF SIZE IS NOT AVAILABLE

CONTRACTOR SHALL REPLACE WITH A 2" CAL. TREE

(DECIDUOUS) OR 6' HEIGHT TREE (EVERGREENS) AND

SHALL PROVIDE A CREDIT TO THE OWNER FOR THE

MONETARY DIFFERENCE IN VALUE.

5. SHOULD CONFLICTS BETWEEN THE PROPOSED

CURBING AND EXISTING TREES EXIST, THE

CONTRACTOR SHALL NOT INSTALL CURBING IN THE

CONFLICT AREA SEE DETAIL D2/C-502.

5.1. FOR ALL CURBING NOT INSTALLED, THE

CONTRACTOR SHALL PROVIDE THE GOVERNMENT

A CREDIT PER LINEAR FOOT NOT INSTALLED.

1.00'

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

24"

6"

2.0%

SCALE: NTS

CURB TERMINATION DETAILF2

1'-5"7"

10"

2'-0"

6"

A/C PAVING

COMPACTED

SUBGRADE PER

SPECIFICATION 32 20 00

LANDSCAPING

SEE PLANS

1/2" RADIUS

BASE THICKNESS EQUAL

TO ROAD BASE, SEE

DETAIL B5/C-501

SCALE: NTS

BUMPER CURBE2

16.0"

6" 1/4" R

1/4" R

5" COMPACTED

AGGREGATE BASE

PER SPECIFICATION

31 20 00

CONCRETE PER

SPECIFICATION 32 05 23

GENERAL NOTES:

1. TWO ROWS OF #4 BARS

CENTERED AS SHOWN.

2. EXPANSION JOINTS

SHALL BE PLACED AT 50'

INTERVALS O.C.

3. CONTROL JOINTS

CONSISTING OF 1" DEEP

SCORES SHALL BE

PLACED AT 10' INTERVALS

O.C.

AutoCAD SHX Text

IRB

AutoCAD SHX Text

IRB

AutoCAD SHX Text

IRB

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBS

AutoCAD SHX Text 391.6

AutoCAD SHX Text

CONC

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBS

AutoCAD SHX Text 391.6

AutoCAD SHX Text

CONC

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

ON-S

IT

E

BU

ILD

IN

G

16"

23"

6"4"

STA:0+00

ST

A:

0+

ST

A:

1+

ST

A:

1+

ST

A:

2+

ST

A:

2+

ST

A:

3+

ST

A:

3+

ST

A:

4+

ST

A:

4+

ST

A:

5+

ST

A:

5+

6"4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - HISTORIC

FRONT ENTRY (BASE BID)

C-403

0 20 40

1 INCH = 20 FEET

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

STORAGE BINS

FRONT ENTRY GATE

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE WALL

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

COMPOSITE FENCE W/ CURBINGVICINITY MAP

NOT TO SCALE

KEYED NOTES

1. AUTOMATIC FRONT ENTRY GATE, SEE SHEET C-509.

2. STANDARD MOW CURB, SEE DETAIL C5/C-507.

3. ORNAMENTAL FENCING WITH STANDARD MOW CURB,

SEE DETAIL SHEETS C-505 & C-506.

4. CONCRETE MAINTENANCE BAND, SEE DETAIL SHEET

C-509.

AOI

GENERAL NOTES:

1. SEE ELECTRICAL PLANS FOR POWER/WIRING DETAILS

FOR AUTOMATIC FRONT ENTRY GATE.

S SEPULVEDA BLVD

C O

N

ST

IT

U

TI

O

N A

VE

SCALE: 1" = 5'

ENLARGED ENTRY GATEC5

1 1

SCALE: 1" = 20'

FRONT ENRTYF5

AUTOMATIC ENTRY GATE NOTES:

1. FRONT ENTRY GATE OPERATOR SHALL BE TYMETAL

CORP. TYM 2000 OR APPROVED EQUAL.

2. SLIDE GATE OPERATOR SHALL BE 1 H.P., 230V.

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 355.6

AutoCAD SHX Text 355.2

AutoCAD SHX Text 348.6

AutoCAD SHX Text 349.4

AutoCAD SHX Text 349.8

AutoCAD SHX Text 358.4

AutoCAD SHX Text 355.4

AutoCAD SHX Text 352.4

AutoCAD SHX Text 353.5

AutoCAD SHX Text 354.3

AutoCAD SHX Text

CONC

AutoCAD SHX Text

PP

AutoCAD SHX Text

PP

AutoCAD SHX Text

PP

AutoCAD SHX Text

PP

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 355.6

AutoCAD SHX Text 355.2

AutoCAD SHX Text 348.6

AutoCAD SHX Text 349.4

AutoCAD SHX Text 349.8

AutoCAD SHX Text 358.4

AutoCAD SHX Text 355.4

AutoCAD SHX Text 352.4

AutoCAD SHX Text 353.5

AutoCAD SHX Text 354.3

AutoCAD SHX Text

CONC

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

PP

AutoCAD SHX Text

PP

AutoCAD SHX Text

PP

AutoCAD SHX Text

PP

AutoCAD SHX Text M

AutoCAD SHX Text G

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 353.5

AutoCAD SHX Text

CONC

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 353.5

AutoCAD SHX Text

CONC

AutoCAD SHX Text M

AutoCAD SHX Text G

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

" D

IA

P

AL

M

" D

IA

P

AL

M

" D

IA

P

AL

M

28"

28"

33"

32"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - SPANISH

AMERICAN MONUMENT FENCING (BASE

BID)

C-404

0 10 20

1 INCH = 10 FEET

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

STORAGE BINS

FRONT ENTRY GATE

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE WALL

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

COMPOSITE FENCE W/ CURBINGVICINITY MAP

NOT TO SCALE

AOI

KEYED NOTES

1. ORNAMENTAL SECURITY FENCING, SEE DETAIL E5 THIS

SHEET.

SCALE: NTS

SPANISH AMERICAN MONUMENTE1

W

IL

SH

IR

E

BL

VD

VETERAN AVE

SEE PLANS

3' -0

6"

2' -0

1'-0"

5" STD PIPE POST

(5.562 O.D.)

3" MAX.

E5SCALE: NTS

ORNAMENTAL FENCING

1" SMASHED POINT SQUARE PICKET

CANTILEVERED 2 PICKETS AT EACH END

3" MAX.

WALL OR MONUMNET

6" TYP.JOIN PERPENDICULAR TO SIGN WALL

GENERAL NOTES:

1. CONTRACTOR SHALL GAIN APPROVAL FOR FINAL

FENCING LOCATION IN WRITING FROM COR PRIOR TO

INSTALLATION.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

EXISTING STONE TILES.

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text D

AutoCAD SHX Text

TS

AutoCAD SHX Text

TS

AutoCAD SHX Text

TS

AutoCAD SHX Text 307.6

AutoCAD SHX Text 309.6

AutoCAD SHX Text 307.6

AutoCAD SHX Text 309.6

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

X

X

X

43"

24"

16"

27"

24"

28" 45"

8"6"6"8"4"

8"6"

8"

25"

27" 19"

25"

34"

36"

6" 6"

6"x7

27"

5"

22"

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+9

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - SOUTHERN

CHAIN LINK FENCING (BASE BID)

C-405

0 60 120

1 INCH = 60 FEET

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

STORAGE BINS

FRONT ENTRY GATE

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE WALL

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

COMPOSITE FENCE W/ CURBING

KEYED NOTES

1. 8' CHAIN LINK FENCING WITH PRIVACY SLATS SEE

SHEET C-504.

2. STANDARD MOW CURB, SEE DETAIL C5/C-507.

VICINITY MAP

NOT TO SCALE

AOI

TOUL AVE

C H

ATEAU

TH

IER

R

Y AVE

TREE PROTECTION NOTES:

1. EXCAVATION OR GRADING WITHIN THE DRIP LINE OF

ANY TREE MUST UTILIZE ALTERNATIVE METHODS SUCH

AS HAND DIGGING TO LOCATE ROOTS.

2. TREE PROTECTION FENCING SHALL BE INSTALLED

AROUND ALL TREES THAT HAVE A DRIP LINE WITHIN

THE LIMITS OF DISTURBANCE FOR CONSTRUCTION

ACTIVITIES OTHER THAN ASPHALT PAVING AND SHALL

EXTEND A MINIMUM OF 10' FROM THE TRUNK OR THE

DRIP LINE OF THE TREE, WHICHEVER IS GREATER.

(TYP)

3. THE CUTTING OF ROOTS GREATER THAN ONE (1) INCH

DIAMETER MUST BE APPROVED AND SUPERVISED BY A

LICENSED ARBORIST.

4. CONTRACTOR SHALL PRESERVE AND PROTECT ALL

TREES FROM DAMAGE BY DEMOLITION OPERATIONS.

ANY TREE DAMAGED BY CONSTRUCTION OPERATIONS

SHALL BE REPLACED WITH A TREE OF THE SAME

SPECIES AND SIZE. IF SIZE IS NOT AVAILABLE

CONTRACTOR SHALL REPLACE WITH A 2" CAL. TREE

(DECIDUOUS) OR 6' HEIGHT TREE (EVERGREENS) AND

SHALL PROVIDE A CREDIT TO THE OWNER FOR THE

MONETARY DIFFERENCE IN VALUE.

5. SHOULD CONFLICTS BETWEEN THE PROPOSED

CURBING AND EXISTING TREES EXIST, THE

CONTRACTOR SHALL NOT INSTALL CURBING IN THE

CONFLICT AREA SEE DETAIL D2/C-502.

5.1. FOR ALL CURBING NOT INSTALLED, THE

CONTRACTOR SHALL PROVIDE THE GOVERNMENT

A CREDIT PER LINEAR FOOT NOT INSTALLED.

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text 317.4

AutoCAD SHX Text 317.4

AutoCAD SHX Text 316.5

AutoCAD SHX Text

AC PAVING

AutoCAD SHX Text

CONC

AutoCAD SHX Text 317.4

AutoCAD SHX Text 317.4

AutoCAD SHX Text 316.5

AutoCAD SHX Text

AC PAVING

AutoCAD SHX Text

CONC

AutoCAD SHX Text M

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

36" DIA PALM

36" DIA PALM

24" DIA PALM

X

26"

28"28"

33"

32"

32"

28"

28"

25"

24"25"

36" 6"

6" 6"

6" 6"

6" 6"x7

27"

ST

A:

+0

ST

A:

+5

ST

A:

+7

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - SOUTHERN

ORNAMENTAL FENCING (BASE BID)

C-406

0 20 40

1 INCH = 20 FEET

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

STORAGE BINS

FRONT ENTRY GATE

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE WALL

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

COMPOSITE FENCE W/ CURBING

KEYED NOTES

1. ORNAMENTAL FENCING, MATCH EXISTING HEIGHT, SEE

DETAIL SHEETS C-505 & C-506.

2. ORNAMENTAL ACCESS GATE, SEE DETAIL SHEETS C-505

& C-506.

VICINITY MAP

NOT TO SCALE

AOI

WILSHIRE BLVD

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text D

AutoCAD SHX Text

TS

AutoCAD SHX Text

TS

AutoCAD SHX Text

TS

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 310.6

AutoCAD SHX Text 309.5

AutoCAD SHX Text 308.4

AutoCAD SHX Text 307.6

AutoCAD SHX Text 308.5

AutoCAD SHX Text 309.6

AutoCAD SHX Text 310.4

AutoCAD SHX Text 311.5

AutoCAD SHX Text 312.4

AutoCAD SHX Text 315.3

AutoCAD SHX Text 314.5

AutoCAD SHX Text 309.6

AutoCAD SHX Text 310.6

AutoCAD SHX Text 309.9

AutoCAD SHX Text 314.2

AutoCAD SHX Text 312.6

AutoCAD SHX Text 311.4

AutoCAD SHX Text

AC PAVING

AutoCAD SHX Text

AC PAVING

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

OBSCURED AREA

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 310.6

AutoCAD SHX Text 309.5

AutoCAD SHX Text 308.4

AutoCAD SHX Text 307.6

AutoCAD SHX Text 308.5

AutoCAD SHX Text 309.6

AutoCAD SHX Text 310.4

AutoCAD SHX Text 311.5

AutoCAD SHX Text 312.4

AutoCAD SHX Text 315.3

AutoCAD SHX Text 314.5

AutoCAD SHX Text 309.6

AutoCAD SHX Text 310.6

AutoCAD SHX Text 309.9

AutoCAD SHX Text 314.2

AutoCAD SHX Text 312.6

AutoCAD SHX Text 311.4

AutoCAD SHX Text

AC PAVING

AutoCAD SHX Text

AC PAVING

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

15"

4"

28"

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+8

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

ST

A:

+5

ST

A:

+0

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

ENLARGED SITE PLAN - EASTERN

ORNAMENTAL FENCING (BASE BID)

C-407

LEGEND AND SYMBOLS

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

STORAGE BINS

FRONT ENTRY GATE

ORNAMENTAL FENCE W/ MOW CURB

CONCRETE WALL

CHAIN LINK FENCE W/ MOW CURB

ORNAMENTAL FENCING

ASPHALT PAVING

CONCRETE PAVING

SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND

EXISTING PROPERTY LINE

EXISTING CHAIN LINK FENCING

COMPOSITE FENCE W/ CURBING

KEYED NOTES

1. ORNAMENTAL FENCING, SEE SHEETS C-505 & C-506.

2. ORNAMENTAL ENTRY GATE. SEE SHEETS C-505 & C-506.

3. VARIABLE HEIGHT MOW CURB, SEE DETAIL C3/C-507.

VICINITY MAP

NOT TO SCALE

0 60 120

1 INCH = 60 FEET

1800 10 20

1 INCH = 10 FEET

AOI

SCALE: 1"=10'

STA: 43+00 TO 45+81F5

SCALE: 1"=10'

STA: 40+00 TO 43+00C5

M

AT

C H

LI

N

E

ST

A:

3+

M

AT

C H

LI

N

E

ST

A:

3+

3 3

TREE PROTECTION NOTES:

1. EXCAVATION OR GRADING WITHIN THE DRIP LINE OF

ANY TREE MUST UTILIZE ALTERNATIVE METHODS SUCH

AS HAND DIGGING TO LOCATE ROOTS.

2. TREE PROTECTION FENCING SHALL BE INSTALLED

AROUND ALL TREES THAT HAVE A DRIP LINE WITHIN

THE LIMITS OF DISTURBANCE FOR CONSTRUCTION

ACTIVITIES OTHER THAN ASPHALT PAVING AND SHALL

EXTEND A MINIMUM OF 10' FROM THE TRUNK OR THE

DRIP LINE OF THE TREE, WHICHEVER IS GREATER.

(TYP)

3. THE CUTTING OF ROOTS GREATER THAN ONE (1) INCH

DIAMETER MUST BE APPROVED AND SUPERVISED BY A

LICENSED ARBORIST.

4. CONTRACTOR SHALL PRESERVE AND PROTECT ALL

TREES FROM DAMAGE BY DEMOLITION OPERATIONS.

ANY TREE DAMAGED BY CONSTRUCTION OPERATIONS

SHALL BE REPLACED WITH A TREE OF THE SAME

SPECIES AND SIZE. IF SIZE IS NOT AVAILABLE

CONTRACTOR SHALL REPLACE WITH A 2" CAL. TREE

(DECIDUOUS) OR 6' HEIGHT TREE (EVERGREENS) AND

SHALL PROVIDE A CREDIT TO THE OWNER FOR THE

MONETARY DIFFERENCE IN VALUE.

5. SHOULD CONFLICTS BETWEEN THE PROPOSED

CURBING AND EXISTING TREES EXIST, THE

CONTRACTOR SHALL NOT INSTALL CURBING IN THE

CONFLICT AREA SEE DETAIL D2/C-502.

5.1. FOR ALL CURBING NOT INSTALLED, THE

CONTRACTOR SHALL PROVIDE THE GOVERNMENT

A CREDIT PER LINEAR FOOT NOT INSTALLED.

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

AutoCAD SHX Text

TS

AutoCAD SHX Text

TS

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 308.4

AutoCAD SHX Text 311.4

AutoCAD SHX Text

OBS

AutoCAD SHX Text

OBS

AutoCAD SHX Text 308.4

AutoCAD SHX Text 311.4

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

HERE

AutoCAD SHX Text

HERE

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

WAIT

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

AutoCAD SHX Text 399.94

AutoCAD SHX Text

AutoCAD SHX Text 330.36

AutoCAD SHX Text

Sheets and Views
G-001 COVER
G-101 SITE ACCESS, FENCING, STAGING AND PHASING PLAN
G-102 OVERALL SITE KEY
V-101 EXISTING CONDITIONS KEY
V-401 EXISTING CONDITIONS - ENLARGED
V-402 EXISTING CONDITIONS - ENLARGED
V-403 EXISTING CONDITIONS - ENLARGED
V-404 EXISTING CONDITIONS - ENLARGED
V-405 EXISTING CONDITIONS - ENLARGED
V-406 EXISTING CONDITIONS - ENLARGED
V-407 EXISTING CONDITIONS - ENLARGED
V-408 EXISTING CONDITIONS - ENLARGED
V-409 EXISTING CONDITIONS - ENLARGED
V-410 EXISTING CONDITIONS - ENLARGED
CG101 EROSIOIN & TREE PROTECTION GENERAL NOTES AND DETAILS
CG401 ENLARGED EROSION PLAN - PRIVACY FENCING AT WATER VALVES (BASE
CG402 ENLARGED EROSION PLAN - DUMPSTER AND SPOILS AREA (BASE BID)
CD101 DEMOLITION PLAN - FLOWER WATER STATIONS, SITE SIGNAGE & SECTION
CD401 ENLARGED DEMOLITION PLAN - DUMPSTER AND SPOILS AREA (BASE BID)
CD402 ENLARGED DEMOLITION PLAN - FULL DEPTH ASPHLAT REMOVAL (BASE BID)
CD403 ENLARGED DEMOLITION PLAN - DRAINAGE CANAL (BASE BID)
CD404 ENLARGED DEMOLITION PLAN - HISTORIC FRONT ENTRY (BASE BID)
CD405 ENLARGED DEMOLITION PLAN - SOUTHERN CHAIN LINK FENCING (BASE BID
CD406 ENLARGED DEMOLITION PLAN - SOUTHERN ORNAMENTAL FENCING (BASE BID
CD407 ENLARGED DEMOLITION PLAN - EASTERN ORNAMENTAL FENCING (BASE BID)
CD408 ENLARGED DEMOLITION PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)
CD409 ENLARGED DEMOLITION PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)
CD410 ENLARGED DEMOLITION PLAN - NORTHERN FENCING (OPTION 2)
CD411 ENLARGED DEMOLITION PLAN - NORTHERN FENCING PHOTOGRAPHS (OPTION
CD412 ENLARGED DEMOLITION PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)
CD413 ENLARGED DEMOLITION PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)
C-101 SITE PLAN - ROADWAY REHABILITATION (BASE BID)
C-102 SITE PLAN - FLOWER WATER STATIONS & NEW SITE SIGNAGE (BASE BID)
C-201 HISTORIC PRESERVATION (BASE BID)
C-202 HISTORIC PRESERVATION (BID OPTION 4)
C-401 ENLARGED SITE PLAN - PRIVACY FENCING AT WATER VALVES (BASE BID)
C-402 ENLARGED SITE PLAN - DUMPSTER AND SPOILS AREA (BASE BID)
C-403 ENLARGED SITE PLAN - HISTORIC FRONT ENTRY (BASE BID)
C-404 ENLARGED SITE PLAN - SPANISH AMERICAN MONUMENT FENCING (BASE BID
C-405 ENLARGED SITE PLAN - SOUTHERN CHAIN LINK FENCING (BASE BID)
C-406 ENLARGED SITE PLAN - SOUTHERN ORNAMENTAL FENCING (BASE BID)
C-407 ENLARGED SITE PLAN - EASTERN ORNAMENTAL FENCING (BASE BID)
C-408 ENLARGED SITE PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)
C-409 ENLARGED SITE PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)
C-410 ENLARGED SITE PLAN - NORTHERN FENCING (OPTION 2)
C-411 ENLARGED SITE PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)
C-412 ENLARGED SITE PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)
C-413 ENLARGED GRADING PLAN - DUMPSTER AND SPOILS AREA (BASE BID)
C-414 ENLARGED FOUNDATION PLAN - MATERIAL STORAGE BINS
C-501 DETAILS - SITE
C-502 DETAILS - SITE
C-503 DETAILS - SIGNAGE
C-504 DETAILS - CHAIN LINK & COMPOSITE FENCING
C-505 DETAILS - ORNAMENTAL FENCING
C-506 DETAILS - ORNAMENTAL FENCING
C-507 DETAILS - FENCE CURBING
C-508 DETAILS - FLOWER WATER STATIONS
C-509 DETAILS - FRONT ENTRY GATE
C-510 DETAILS - MATERIAL STORAGE BINS
C-511 DETAILS - MATERIAL STORAGE BINS & GENERAL REINFORCING
C-512 DETAILS - MATERIAL STORAGE BIN ROOF
HD101 HAZARDOUS MATERIALS ABATEMENT - LEAD BASED PAINT
898-036-Exhibibts - 1
898-036-Exhibibts - 2.0
898-036-Exhibibts - 3
898-036-Exhibibts - 4
898-036-Exhibibts - 5
898-036-Exhibibts - 6
898-036-Exhibibts - 7
898-036-Exhibibts - 8
898-036-Exhibibts - 9
898-036-Exhibibts - 10
898-036-Exhibibts - 11
898-036-Exhibibts - 12
898-036-Exhibibts - 13
898-036-Exhibibts - 14
898-036-Exhibibts - 15
898-036-Exhibibts - 16
898-036-Exhibibts - Tree 1
898-036-Exhibibts - Tree 1 (2)
898-036-Exhibibts - Tree 1 (3)
898-036-Exhibibts - Tree 1 (4)

File details come from the government source that posted it. Updated .