The solicitation is for maintenance and facility condition assessment services for VA National Cemetery Administration site(s) in the Los Angeles, CA area. The contract has a base period of one year with four one-year option periods. Pricing is requested on a fixed-price basis. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs). Proposals are due by October 28, 2022, and the anticipated award date is November 30, 2022. The incumbent contractor is not identified.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
SHEET
NO. DRAWING NO. SHEET TITLE
PROJECT TEAM
SITE LOCATION MAP
SCALE: NTS N
SITE LOCATION AND ACCESS MAP
SCALE: NTS N
LOS ANGELES NC
LOS ANGELES NC
MAINTENANCE YARD
ARCHITECT / ENGINEER
VALI COOPER INTERNATIONAL, LLC
COVINGTON, LA 70433
CONTACT: SEAN FITZPATRICK
SEAN@VALIINT.COM
504-378-7399
SITE OWNER
VA NCA
LOS ANGELES NATIONAL CEMETERY
CONTACT: JUAN KAYS
JUAN.KAYS@VA.GOV
202-632-5057
SURVEYOR
ATC DESIGN GROUP
ESCONDIDO, CA 92029
CONTACT: RYAN POST
RPOST@ATCDESIGNGROUP.COM
760-738-8800
HAZARDOUS MATERIALS
TERRACON
TUSTIN, CA 92750
CONTACT: VICTOR NGUYEN
VICTOR.NGUYEN@TERRACON.COM
310-627-3430
STRUCTURAL
DCI
Los Angeles, CA 90049
CONTACT: NOLAN LENAHAN
NLENAHAN@DCI-ENGINEERS.COM
213-298-3700
DEPARTMENT OF VETERANS AFFAIRS
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
NCA PROJECT NO. 898CM3034
Los Angeles, CA
G-001 COVER SHEET
G-101 SITE ACCESS, FENCING AND STAGING PLAN
GC101 EROSION AND SEDIMENTATION CONTROL PLAN
V-101 TOPOGRAPHIC SURVEY
CD101 DEMOLITION PLAN - SITE
CD102 DEMOLITION PLAN - UTILITIES
C-101 SITE PLAN
C-102 UTILITY PLAN
C-103 GRADING PLAN
C-104 JOINTING PLAN
C-201 STORM DRAINAGE PROFILES
C-202 SANITARY SEWER PROFILES
C-501 DETAILS - SITE
C-502 DETAILS - UTILITIES
C-503 DETAILS - UTILITIES
C-504 DETAILS - EROSION AND SEDIMENTATION CONTROL
LD101 IRRIGATION DEMOLITION PLAN
LI101 IRRIGATION PLAN
LI501 IRRIGATION & PLANTING DETAILS
LP101 PLANTING PLAN
D-101 SITE & BUILDING DEMOLITION PLAN
D-102 DEMOLITION DETAILS
A-001 ARCHITECTURAL LEGENDS AND NOTES
A-101 ARCHITECTURAL SITE PLAN
A-102 MAIN FLOOR PLANS
A-103 REFLECTED CEILING PLANS
A-104 ROOF PLANS
A-201 ADMINISTRATION & STORAGE BUILDING EXTERIOR ELEVATIONS
A-202 MAINTENANCE & COVERED STORAGE EXTERIOR ELEVATIONS
A-301 AMINISTRATION & STORAGE BUILDING & WALL SECTIONS
A-302 MAINTENANCE & COVERED STORAGE BUILDING & WALL SECTIONS
A-401 ENLARGED PLANS & INTERIOR ELEVATIONS
A-501 INTERIOR DETAILS
A-502 DOOR & WINDOW DETAILS
A-503 MISC. DETAILS
S-001 GENERAL NOTES
S-002 GENERAL NOTES
S-003 SPECIAL INSPECTIONS AND ABBREVIATIONS
S-101 SITE OVERALL PLAN
S-102 ADMINISTRATION AND STORAGE BUILDING FOUNDATION PLAN
S-103 ADMINISTRATION AND STORAGE ROOF FRAMING PLAN
S-104 MAINTENANCE BUILDING AND COVERED PARKING FOUNDATION PLAN
S-105 MAINTENANCE BUILDING AND COVERED PARKING ROOF FRAMING PLAN
S-501 STRUCTURAL - FOUNDATION DETAILS
S-502 STRUCTURAL - FOUNDATION DETAILS
S-503 STRUCTURAL - CMU FRAMING DETAILS
S-504 STRUCTURAL - CFS FRAMING DETAILS
S-505 STRUCTURAL - CFS FRAMING DETAILS
S-506 STRUCTURAL - FRAMING DETAILS
S-507 STRUCTURAL - FRAMING DETAILS
S-508 STRUCTURAL - FRAMING DETAILS
M-001 MECHANICAL SYMBOLS & ABBREVIATIONS
MH101 HVAC FLOOR PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
P-001 PLUMBING SYMBOLS & ABBREVIATIONS
P-101 PLUMBING FLOOR PLANS
P-102 PLUMBING FLOOR PLANS
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
E-001 MEDIUM VOLTAGE POWER PLAN LAYOUT
E-002 ONELINE DIAGRAMS
E-003 POWER PLAN ONELINE AND PANEL LAYOUT
E-004 ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
EL101 OVERALL LIGHTING PLAN LAYOUT
EL102 STORAGE BUILDING LIGHTING LAYOUT
EL103 ADMINISTRATION BUILDING LIGHTING LAYOUT
EL104 MAINTENANCE BUILDING LIGHTING LAYOUT
EL601 LIGHTING SCHEDULE
EP101 OVERALL POWER PLAN
EP102 STORAGE BUILDING POWER LAYOUT
EP103 ADMINISTRATION BUILDING POWER LAYOUT
EP104 MAINTENANCE BUILDING POWER LAYOUT
EP105 ADMINISTRATION BUILDING ENLARGED PLAN AND SECTION VIEW
EP106 ADMINISTRATION BUILDING ELECTRICAL SECTION VIEWS
EP107 ELECTRIC DETAILS
EP601 PANEL A SCHEDULE
EP602 PANEL A-1 SCHEDULE
EP603 PANEL A-2 SCHEDULE
EP604 PANEL B SCHEDULE
EP605 PANEL C SCHEDULE
EP606 PANEL C-1 SCHEDULE
T-101 SECURITY CONTROL - PLAN LAYOUT
T-102 SECURITY CONTROL - KEYLESS ENTRY DETAILS
T-103 INFORMATION TECHNOLOGY (IT) LAYOUT
T-104 INFORMATION TECHNOLOGY (IT)
T-105 INFORMATION TECHNOLOGY (IT)
T-106 INFORMATION TECHNOLOGY (IT)
T-107 DETAILS FOR 12RU SECONDARY ENCLOSURE
T-108 BONDING FOR COMMUNICATION
T-109 WALL-MOUNT CABINET SPECS
HD101 HAZMAT DEMOLITION PLAN
HD901 HAZMAT DEMOLITION PHOTOS, MAINT. STORAGE BUILDING
HD902 HAZMAT DEMOLITION PHOTOS, MAINT. ADMIN. BUILDING & YARD
ELECTRICAL / TELECOMMUNICATIONS
JD ENGINEERING
HAMILTON, MT 59840
CONTACT: SCOTT TURNER
SCOTT & JDENG.ORG
206-218-9980
1. BURIAL CEREMONIES WILL BE SCHEDULED THROUGHOUT THE COURSE OF THIS PROJECT.
COORDINATE DAILY ACTIVITIES WITH THE CEMETERY DIRECTOR OR HIS APPROVED REPRESENTATIVE TO ACCOMMODATE SCHEDULED BURIALS (COLUMBARIUM WALLS). CONTRACTOR SHALL OBTAIN THE SCHEDULE FOR THE NEXT DAY SERVICES PRIOR TO THE CLOSE OF BUSINESS EACH DAY. ALLOWABLE
WORK TO BE DETERMINED BY THE CEMETERY DIRECTOR.
2. BECAUSE OF THE SENSITIVE NATURE OF THE CEMETERY SITE, CONTRACTOR SHALL MAINTAIN EACH
WORK AREA IN A CLEAN AND ORDERLY APPEARANCE. TRASH AND WASTE MATERIALS SHALL BE
STORED IN APPROVED CONTAINERS AND ROUTINELY DISPOSED OFF-SITE. CLEANUP SHALL BE
REQUIRED AT THE END OF EACH DAY AND/OR MORE FREQUENTLY AS REQUIRED.
3. THE CONTRACTORS STAFF AND SUBCONTRACTORS STAFF SHALL NOT:
DRESS IN SLEEVELESS SHIRTS OR SHORT PANTS, WEAR CLOTHING WITH INAPPROPRIATE LOGOS, PLAY MUSIC, TALK LOUD, PLACE PERSONAL ITEMS ON HEADSTONES, LEAN AGAINST OR SIT ON
HEADSTONES.
4. THE EFFECT OF WORK ON PUBLIC ACCESS SHALL BE MINIMAL AND SHALL BE COORDINATED WITH THE
CEMETERY DIRECTOR. ANY ALTERED PUBLIC TRAFFIC ROUTES SHALL BE WELL DEFINED WITH
PROFESSIONALLY MADE SIGNAGE AND/OR OTHER APPROVED CONVENTIONAL METHODS.
5. DO NOT WORK UPON NOR STORE ANY MATERIALS ON OCCUPIED COLUMBARIUM WALLS. ALL EFFORT
WILL BE MADE TO MAINTAIN DISTANCE FROM OCCUPIED COLUMBARIUM WALLS.
CODE OF CONDUCT
1. TOPOGRAPHIC INFORMATION PROVIDED BY SURVEY PERFORMED BY ATC DESIGN GROUP DATED
DECEMBER 1, 2021. THE GENERAL CONTRACTOR SHALL VERIFY ALL SURVEY INFORMATION.
2. THE BASIS OF BEARINGS FOR THE SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, ZONE 5 CCS83 (2017.5 EPOCH) AS DETERMINED LOCALLY BY FIELD OBSERVED TIES TO CONTINUOUS OPERATING REFERENCE STATION (CORS) "BLSA" HAVING A CALIFORNIA COORDINATE VALUE OF 1ST ORDER
ACCURACY OR BETTER.
3. THE EXISTING UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE INFORMATION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL UTILITIES
PRIOR TO BEGINNING ANY WORK. IF UTILITIES OTHER THAN THOSE SHOWN HEREON ARE
ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY AND TAKE APPROPRIATE
MEASURES TO PROTECT THE LINE(S) AND ENSURE CONTINUED SERVICE. DAMAGE CAUSED TO
EXISTING UTILITIES BY THE CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL VERIFY THE CONNECTION POINTS OF
NEW UTILITIES TO EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION.
4. THE CONTRACTOR SHALL INSTALL TREE PROTECTION BARRICADES PRIOR TO BEGINNING EARTHWORK
OPERATIONS.
5. THE CONTRACTOR SHALL NOTIFY THE COR IF UNSUITABLE MATERIAL IS DISCOVERED PRIOR TO
BEGINNING ANY REMOVAL OPERATION. (SEE SPECIFICATION SECTION 31.20.00)
6. THE CONTRACTOR SHALL STABILIZE ALL DISTURBED AREA WITH SOD OR MULCH, NOT SHOWN FOR ASPHALT OR CONCRETE, WITHIN LIMITS OF DEMOLITION AND PROPOSED WORK. THIS INCLUDES
STAGING AREA AND LAYDOWN AREAS.
7. CONTRACTOR SHALL GRADE ALL DISTURBED AREAS TO DRAIN FOR POSITIVE FLOW PRIOR TO FINAL
APPROVAL.
8. THE DESIGN ADEQUACY AND SAFETY OF ALL BRACING, SHORING AND TEMPORARY SUPPORTS, ETC. IS
THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
9. IN PERFORMING CONSTRUCTION OBSERVATION VISITS TO THE JOB SITE, THE ENGINEER SHALL HAVE
NEITHER CONTROL OVER NOR RESPONSIBILITY FOR THE CONTRACTOR'S MEANS, METHODS,
SEQUENCE, TECHNIQUES OR PROCEDURES IN PERFORMING THE WORK.
10. THE CONTRACTOR'S MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES IN PERFORMING THE WORK IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR, WHO IS ALSO RESPONSIBLE FOR
COMPLYING WITH ALL HEALTH AND SAFETY PRECAUTIONS AS REQUIRED BY ANY REGULATORY
AGENCY.
11. THERE SHALL BE AT ALL TIMES, WHEN WORK IS BEING DONE, A COMPETENT PERSON WHO IS APPRISED OF THE CONDITION AND PROGRESS OF ALL AREAS OF WORK ON SITE. THIS COMPETENT PERSON SHALL BE ABLE TO SPEAK FOR AND ACT IN THE BEHALF OF THE CONTRACTOR. HE SHALL BE
AWARE AND KNOWLEDGEABLE OF ALL THE SAFETY CONCERNS ON THE JOB SITE. HE SHALL BE
EMPOWERED TO IMMEDIATELY AND EFFECTIVELY MITIGATE THE ACTIONS OF ANY WORKMAN ON SITE.
12. CONTRACTOR SHALL PREPARE AND SUBMIT A WELDING PLAN TO THE COR PRIOR TO PERFORMING
ANY FIELD WELDING SHOULD IT BE REQUIRED. FOLLOWING APPROVAL ALL WELDS SHALL BE
PERFORMED IN ACCORDANCE WITH THE APPROVED PLAN.
GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMTERY
REPLACE STORAGE BUILDING
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI Project Management Construction Management Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366CO
LO
RADO L ICENSED
A RC H I T ECT
SE
AN
M. F ITZPATRICK
C :\U se rs
\s ea n\
VC
I\L
AN
C G ra ve si te
E xp an si on (C ol um ba riu m
D oc um en ts \a
W or kF ile s_ M ai nt en an ce \5
_B id
_D oc s\ 1_
Pl an s\ C
AD
\L
AN
C
_8
C M
_M ai nt _A rc hi te ct ur al
.rv t
5/
/2
8:
:1
AM
G-001
COVER SHEET
FITZ TM
Revisions: Date:
Project Director
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
0 0 0
ON SAFETY
ZERO
Department of Veterans Affairs
PAINTED BORDER MEMBER
BLACK ENAMEL
2" X 4" FRAME AND BRACES IN
SAME PLANE
METAL FACE
STRETCH METAL FACE TIGHT,
TURN OVER FRAME AND SECURE
WITH FLAT HEAD DEFORMED NAILS
LETTERING TO BE HELVETICA
STYLE 5" HIGH
METAL FACE WHITE ENAMEL
LETTERING TO BE HELVETICA
STYLE 3" HIGH TO BE
CENTERED HORIZONTALLY
2" X 4" FRAME AND BRACE IN
BACK
LETTERING TO BE HELVETICA
STYLE 2" HIGH TO BE CENTERED
HORIZONTALLY
LETTERING TO BE HELVETICA
STYLE 1-1/2" HIGH TO BE
CENTERED HORIZONTALLY
4" X 4" POSTS PAINTED
WHITE
BORDER MEMBER PAINTED
BLACK
BACKGROUND TO BE PAINTED
WHITE
LETTERING TO BE HELVETICA
STYLE 1" HIGH TO BE
CENTERED HORIZONTALLY
LETTERING TO BE HELVETICA
STYLE 1-1/2" HIGH TO BE
CENTERED HORIZONTALLY
SURROUNDING BORDER TO BE
BLUE
CENTER TO BE WHITE
8'-8"
6'-6"
6"
1-1/2"
3"
5"
2"
5"
5"
3" 2"
1-1/2"
4'-0" MIN.
3"
6"
9"
6"
3" 2" 3"
6"
ALL LETTERING TO BE PAINTED
BLACK WITH EXCEPTION OF
PROJECT TITLE WHICH IS TO BE
BLUE
NOTE:
ANY SEAM IN METAL TO BE FLAT
SEAM - SEAMS TO BE HORIZONTAL
AND OCCUR BETWEEN LINES OF
LETTERING.
SECTION ON CENTER
4'-0"
BRACING SEE
CONSTRUCTION SIGN
SECTION DETAIL C7/A-509
3'-0"
VARIES
3'-0"
BLUE
BLUE OUTLINE WITH WHITE
INTERIOR
BLUE
WHITE
RED
RED
2"
2"
PROVIDE (3) SETS OF REMOVABLE
NUMERALS PAINTED ON 1/8" TEMPERED
HARDBOARD
2"
1-3/4"
2"
WOOD STRIPS
BRACING
4" X 4" POST IF SIGN IS
INSTALLED ON GRADE
FIN. GRADE
VARIES;
AVERAGE 3'-0"
LEGEND AND SYMBOLS
CONSTRUCTION STAGING AREA
PROJECT & SAFETY SIGNAGE
CONSTRUCTION FENCE
ACCESS / HAUL ROUTE
PROJECT SIGN; SEE
DETAIL F8 THIS SHEET
SAFETY SIGN; SEE
DETAIL C8 THIS SHEET
CONSTRUCTION
FENCING WITH
LOCKABLE 20' ACCESS
GATE ACCESS/HAUL
ROUTE
ALTERNATIVE
CONSTRUCTION
STAGING AREA
MAIN CONSTRUCTION STAGING
AREA, SEE GRAVE SITE
EXPANSION PLAN SET FOR
ADDITIONAL DETAILS
SITE ACCESS, FENCING AND STAGING
PLAN
G-101
ALTERNATE CONSTRUCTION STAGING AREA NOTES:
1. CONTRACTOR SHALL PLACE CONSTRUCTION FENCING WITH
PRIVACY FABRIC AROUND THE ENTIRE PERIMETER OF THE
STAGING AREA.
2. CONTRACTOR SHALL PROVIDE A LOCKABLE ACCESS GATE.
3. CONTRACTOR SHALL PLACE SILT FENCING AROUND THE ENTIRE
PERIMETER OF THE STAGING AREA.
4. CONTRACTOR SHALL PLACE A CONSTRUCTION ENTRANCE AT
THE BACK ENTRANCE ONTO VERTRAN AVE SHOULD THE
ENTRANCE BE USED BY CONSTRUCTION TRAFFIC OF ANY TYPE.
SIGNAGE NOTES:
1. CONTRACTOR SHALL ONLY PLACE ONE PROJECT AND ONE
SAFETY SIGN AT THE ENTRANCE OF THE CEMETERY EAST OF
THE 405 SHOULD THE FCA DEFICIENCIES PROJECT BE AWARDED
AS A PART OF THIS CONTRACT.
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INE ER
05/24/2023
AMIENS AVENUE
SOISSONS AVENUE
370.360
IE
373.820
IE
378.900
TG B
379.020
TG
378.750
TG E
378.820
TG
379.580
TC B
379.420
INLET B
379.520
INLET E
X
X
X
X
X
X
X
X
CO
CO
387 388 389
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
LIMITS OF DISTURBANCE
LEGEND AND SYMBOLS
EROSIOIN CONTROL NOTES:
1. TEMPORARY EROSION CONTROL DEVICES SHOWN ON
THE GRADING PLAN WHICH INTERFERE WITH THE
WORK SHALL BE RELOCATED OR MODIFIED WITH
APPROVAL FROM THE COR AS THE WORK
PROGRESSES TO MEET "AS GRADED" CONDITIONS.
2. ALL LOOSE SOIL AND DEBRIS SHALL BE REMOVED
FROM THE STREET AREAS UPON STARTING
OPERATIONS AND PERIODICALLY THEREAFTER AS
DIRECTED BY THE COR .
DUST CONTROL NOTES:
1. DUST SHALL BE CONTROLLED BY WATERING AND/OR
APPLYING A DUST PALLIATIVE.
2. WATER FOR DUST CONTROL SHALL BE APPLIED BY
MEANS OF PRESSURE TYPE DISTRIBUTORS OR PIPE
LINES EQUIPPED WITH A SPRAY SYSTEM OR HOSES
WITH NOZZLES THAT WILL ENSURE A UNIFORM
APPLICATION OF WATER.
3. UNLESS WATER IS APPLIED BY MEANS OF PIPE LINES,
AT LEAST ONE MOBILE UNIT WITH A MINIMUM
CAPACITY OF 100 GALLONS SHALL BE AVAILABLE FOR
APPLYING WATER.
4. ALL SOIL MATERIALS OR DEBRIS TRUCKED FROM THE
SITE SHALL BE COVERED AND MOISTENED PRIOR TO
ENTERING PUBLIC STREETS.
SILT FENCING
INLET PROTECTION
CONSTRUCTION ENTRANCE
CONCRETE WASHOUT AREA
KEYED NOTES
1. INLET PROTECTION, SEE DETAIL, SEE DETAIL B2/ C-504
2. SILT FENCE OR FIBER ROLLS, SEE DETAIL D2/ C-504
3. CONSTRUCTION ENTRANCE, SEE DETAIL B9/C-504.
4. CONCRETE WASHOUT AREA, SEE DETAIL B5/C-504.
5. CONSTRUCTION FENCING WITH PRIVACY FABRIC.
CONSTRUCTION FENCING
0 10 20
1 INCH = 10 FEET
EROSION AND SEDIMENTATION
CONTROL PLAN
GC101
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
TM
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
0 10 20
1 INCH = 10 FEET
VICINITY MAP
SITE
BASIS OF BEARINGS BENCHMARK
TOPOGRAPHIC SURVEY
V-101
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
370.360
IE
373.820
IE
378.900
TG B
379.150
TG
379.020
TG
378.750
TG E
378.820
TG
379.080
TG 5.2 DIP
379.580
TC B
379.420
INLET B
379.520
INLET E
8" DIA CYPRESS
24" DIA EUCALYPTUS
24" DIA EUCALYPTUS
12" DIA EUCALYPTUS
18" DIA EUCALYPTUS
12" DIA EUCALYPTUS
6" DIA EUCALYPTUS
36" DIA EUCALYPTUS
12" DIA EUCALYPTUS
6" DIA PEPPER TREE
6" DIA EUCALYPTUS
8" DIA EUCALYPTUS
12" DIA SPINELESS YUCCA
12" MULTI TRUNK EUCALYPTUS
24" DIA EUCALYPTUS
36" DIA EUCALYPTUS
36" DIA EUCALYPTUS
48" DIA EUCALYPTUS
12" MULTI TRUNK EUCALYPTUS
36" DIA EUCALYPTUS
24" DIA EUCALYPTUS
12" DIA EUCALYPTUS
24" DIA EUCALYPTUS
36" DIA EUCALYPTUS
24" DIA EUCALYPTUS
36" DIA EUCALYPTUS
8" DIA CYPRESS 8" DIA CYPRESS
X
X
X
X
X
X
X
X
X
X
X
0 10 20
1 INCH = 10 FEET
1. SAW CUT AND REMOVE EXISTING ASPHALT PAVING.
2. REMOVE REINFORCED CONCRETE PAVING AND
MISCELLANEOUS FLATWORK.
3. REMOVE EXISTING GRAVEL PARKING AREA.
4. REMOVE EXISTING CONCRETE WASH BAY AND ALL
APPURTENANCES.
5. REMOVE FLAMMABLE STORAGE BUILDING.
6. REMOVE C.M.U. / STONE BUILDING.
7. DEMOLISH AND REMOVE EXISTING MAINTENANCE.
BUILDING AND ASSOCIATED FOUNDATIONS.
8. NOT USED
9. REMOVE C.M.U. STONE WALL.
10. REMOVE EXISTING RAILROAD TIE RETAINING WALL.
11. REMOVE EXISTING C.M.U. RETAINING WALLS.
12. REMOVE RAILROAD TIE PLANTER.
13. REMOVE BRUSH AND VEGETATION AS NEEDED FOR
EXCAVATION.
14. REMOVE EXISTING TREE, STUMP AND ASSOCIATED ROOT
MASS.
15. REMOVE EXISTING TREE. STUMP AND ROOT MASS TO
REMAIN, SEE GENERAL NOTES BELOW.
16. REMOVE EXISTING MOW CURB.
17. PRESERVE EXISTING STORAGE BUILDING PER
ARCHITECTURAL PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
EXISTING STORAGE BUILDING
(SEE OTHER PLANS FOR
LIMITS OF DEMOLITION)
EXISTING MAINTENANCE BUILDING
(TO BE DEMOLISHED)
EXISTING VEHICLE
WASH AREA
(TO BE REMOVED)
AMIENS AVENUE
SOISSONS AVENUE
KEYED NOTES
DEMOLITION PLAN - SITE
CD101
GENERAL NOTES:
1. SEE ELECTRICAL, MECHANICAL, LANDSCAPE,
ARCHITECTURAL AND STRUCTURAL DEMOLITION PLANS
FOR ADDITIONAL DEMOLITION REQUIREMENTS.
2. CONTRACTOR SHALL PRESERVE AND PROTECT THE
EXISTING ENTRY GATE.
3. CONTRACTOR SHALL PRESERVE AND PROTECT ALL
EXISTING LANDSCAPING AND IRRIGATION.
4. CONTRACTOR SHALL REPAIR ALL DAMAGED TURF WITH
IMPORTED SOIL AND SOD PER TURF RENOVATION SPECIES
TO THE SATISFACTION OF THE COR AT NO ADDITIONAL
COST TO THE GOVERNMENT.
LEGEND AND SYMBOLS
EX. CONTOUR MAJOR
EX. CONTOUR MINOR
EX. CURB & GUTTER
EX. SIDEWALK
EX. TREE (TYP.)
EX. MANHOLE
EX. UTILITY BOX
EX. C.M.U. RETAINING WALL
GRAVEL PARKING REMOVAL
EX. CHAIN LINK FENCING
DEMO CHAIN LINK FENCING
SAW CUT ASPHALT
ASPHALT REMOVAL
CONCRETE REMOVAL
X
*SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND
EX. GATE
7 7
15 15
COBBLE STONE WALL
DEMO COBBLE STONE WALL
PRESERVE AND PROTECT
LIMITS OF DISTURBANCE
TREE AND STUMP REMOVAL
TREE REMOVAL
START WALL
REMOVAL
END WALL
REMOVAL
TREE REMOVAL NOTES:
1. ALL TREE STUMPS TO REMAIN SHALL BE CUT NO HIGHER
THAN 1' ABOVE GRADE.
2. FOR TREE STUMPS TO REMAIN, CONTRACTOR SHALL
INSTALL *GROW MORE STUMP REMOVER (OR APPROVED
EQUAL) PER MANUFACTURERS PRINTED INSTRUCTIONS.
3. FOR TREE STUMPS TO BE REMOVED OUTSIDE OF THE
LIMITS OF DISTURBANCE, THE CONTRACTOR SHALL REPAIR
ALL DISTURBED ARES TO MATCH THE ADJACENT
LANDSCAPING AT NO ADDITIONAL COST TO THE
GOVERNMENT.
4. CONTRACTOR SHALL REPAIR ALL DAMAGED VEGETATION
OUTSIDE OF THE LIMITS OF DISTURBANCE TO THE
SATISFACTION OF THE COR AT NO ADDITIONAL COST TO
THE GOVERNMENT.
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
370.360
IE
373.820
IE
378.900
TG B
379.150
TG
379.020
TG
378.750
TG E
378.820
TG
379.080
TG 5.2 DIP
379.580
TC B
379.420
INLET B
379.520
INLET E
8" DIA CYPRESS
24" DIA EUCALYPTUS
24" DIA EUCALYPTUS
12" DIA EUCALYPTUS
18" DIA EUCALYPTUS
12" DIA EUCALYPTUS
6" DIA EUCALYPTUS
36" DIA EUCALYPTUS
12" DIA EUCALYPTUS
6" DIA PEPPER TREE
6" DIA EUCALYPTUS
8" DIA EUCALYPTUS
12" DIA SPINELESS YUCCA
12" MULTI TRUNK EUCALYPTUS
24" DIA EUCALYPTUS
36" DIA EUCALYPTUS
36" DIA EUCALYPTUS
48" DIA EUCALYPTUS
12" MULTI TRUNK EUCALYPTUS
36" DIA EUCALYPTUS
24" DIA EUCALYPTUS
12" DIA EUCALYPTUS
24" DIA EUCALYPTUS
36" DIA EUCALYPTUS
24" DIA EUCALYPTUS
36" DIA EUCALYPTUS
8" DIA CYPRESS 8" DIA CYPRESS
X
X
X
X
X
X
X
X
X
X
X
0 10 20
1 INCH = 10 FEET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
DEMOLITION PLAN - UTILITIES
CD102
SOISSONS AVENUE
1. REMOVE EXISTING WATER LINE.
2. REMOVE EXISTING SANITARY SEWER.
3. REMOVE EXISTING HOSE BIB.
4. REMOVE EXISTING WATER VALVE.
5. REMOVE EXISTING CLEANOUT.
6. REMOVE EXISTING DRAINAGE INLET AND ASSOCIATED
PIPING.
7. REMOVE ALL DRAINAGE/SEWER LINES ASSOCIATED WITH
THE EXISTING WASH BAY.
8. REMOVE EXISTING WATER STORAGE TANK AND ALL
ASSOCIATED PIPING.
9. RELOCATE 500 GALLON FUEL TANK.
10. REMOVE EXISTING FUEL TANK AND ALL ASSOCIATED
APPURTENANCES.
KEYED NOTES
GENERAL NOTES:
1. SEE ELECTRICAL, MECHANICAL, LANDSCAPE,
ARCHITECTURAL AND STRUCTURAL DEMOLITION
PLANS FOR ADDITIONAL DEMOLITION REQUIREMENTS.
2. CONTRACTOR SHALL REMOVE THE EXISTING POTABLE
WATER DISTRIBUTION LINE FROM THE EXISTING
MAINTENANCE YARD, TO THE NEAREST VALVE AT NO
ADDITIONAL COST TO THE GOVERNMENT.
2.1. CONTRACTOR SHALL BID THE REMOVAL OF 125 L.F.
OF WATER DISTRIBUTION LINE.
2.2. CONTRACTOR SHALL FIELD VERIFY WATER LINE
CONNECTION POINT PRIOR TO CONSTRUCTION.
3. CONTRACTOR SHALL REPAIR ALL DAMAGED TURF WITH
IMPORTED SOIL AND SOD PER TURF RENOVATION
SPECIES TO THE SATISFACTION OF THE COR AT NO
ADDITIONAL COST TO THE GOVERNMENT. MODIFY ALL
IMPACTED IRRIGATION HEADS AS DIRECTED BY COR.
4. THE CONTRACTOR SHALL CONFIRM WITH CEMETERY
WHICH FUEL TANK IS TO BE REMOVED AND WHICH IS
TO BE RELOCATED.
LEGEND AND SYMBOLS
EX. CONTOUR MAJOR
EX. CONTOUR MINOR
EX. CURB & GUTTER
EX. SIDEWALK
EX. TREE (TYP.)
EX. MANHOLE
EX. UTILITY BOX
EX. C.M.U. RETAINING WALL
EX. CHAIN LINK FENCING
DEMO SEWER LINE
*SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND
EX. GATE
COBBLE STONE WALL
DEMO WATER LINE
RENOVATED BRICK STORAGE BUILDING DEMOLITION NOTES:
1. CONTRACTOR SHALL REMOVE ALL SANITARY SEWER
SERVICE LINES CONNECTED TO THE BUILDING UP TO THE
EXISTING FOUNDATION.
1.1. CONTRACTOR SHALL FILL WITH CONCRETE SLURRY
AND ABANDON IN PLACE ALL SANITARY SEWER
SERVICE LINES UNDERNEATH THE EXISTING
FOUNDATION.
2. CONTRACTOR SHALL REMOVE ALL WATER SERVICE LINES
CONNECTED TO THE BUILDING UP TO THE EXISTING
FOUNDATION.
2.1. CONTRACTOR SHALL ABANDON IN PLACE ALL WATER
SERVICE LINES UNDERNEATH THE EXISTING
FOUNDATION.
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
6.00'
8.00'
10.00'
10.00'
24.00'
24.00'
50.00'
8.00'
12.00'
9.57'
9.75'
9.75'
.5
7'
.0
0'
8.
.8 1'
.7
4'
.8
1'
.1
7' 22.00'
20.05'
.0
0'
9.14'
9.
3.50'
2.48'
5.
5.50'
X
X
X
X
X
X
X
X
RENOVATED BRICK
STORAGE BUILDING
MAINTENANCE VEHICLE
PARKING
EMPLOYEE PARKING
VEHICLE WASH AREA
AMIENS AVENUE
SOISSONS AVENUE
CO
CO
10.00'TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
1. 4' WIDE VALLEY GUTTER, SEE DETAIL F2/C-501.
2. ROLLED TYPE CURB AND GUTTER, TRANSITION FROM
VALLEY TYPE TO SPILL TYPE OVER 1', SEE DETAIL
D2/C-501.
3. STANDARD CURB AND GUTTER, SEE DETAIL B5/C-501.
4. 5" WIDE, WHITE PARKING LOT STRIPING, SEE
SPECIFICATIONS.
5. DRAINAGE STRUCTURE, SEE SHEET C-103.
6. SANITARY SEWER STRUCTURE AND OR SEPERATOR,
SEE SHEET C-102.
7. LANDSCAPE CURB, SEE DETAIL F5/C-501.
8. C.M.U. RETAINING WALL, SEE SHEET S-301.
9. ASPHALT PAVEMENT, SEE DETAIL A2/C-501.
10. CONCRETE PAVEMENT, SEE DETAIL F8/C-501.
11. RAILROAD TIE RETAINING WALL, SEE DETAIL F8/C-504 &
GENERAL NOTES BELOW.
12. FUEL TANK PAD, SEE DETAIL F5/C-504 .
13. RELOCATED 500 GALLON ABOVE GROUND FUEL TANK.
14. REMOVABLE BOLLARD, SEE DETAIL D5/C-504 .
NEW ADMINISTRATION
BUILDING
NE
W
M
AI
NT
EN
AN
CE
BU
IL
DI
NG
NEW COVERED VEHICLE
STORAGE
0 10 20
1 INCH = 10 FEET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
SITE PLAN
C-101
KEYED NOTES
GENERAL NOTES:
1. CONTRACTOR SHALL PLACE A NON-DOWELED
EXPANSION JOINT AROUND THE PERIMETER OF THE
CONCRETE PAVING.
2. CONTRACTOR SHALL PLACE A DOWELED EXPANSION
JOINT AROUND THE PERIMETER OF THE VALLEY
GUTTER.
3. CONTRACTOR SHALL PROVIDE A JOINTING PLAN FOR
APPROVAL BY THE COR 60 DAYS PRIOR TO THE
PLACEMENT OF CONCRETE.
4. CONTRACTOR SHALL FOLD NEW RAILROAD TIES INTO
THE EXISTING RAILROAD TIE RETAINING WALL.
5. CONTRACTOR SHALL MATCH EXISTING GRADES ALONG
AMIENS AVE.
6. CONTRACTOR SHALL TERMINATE LANDSCAPE CURB AT
ALL UTILITY BOXES.
LEGEND AND SYMBOLS
EX. CONTOUR MAJOR
EX. CONTOUR MINOR
EX. CURB & GUTTER
EX. SIDEWALK
EX. TREE (TYP.)
EX. MANHOLE
EX. UTILITY BOX
EX. C.M.U. RETAINING WALL
EX. CHAIN LINK FENCING
*SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND
EX. GATE
ASPHALT PAVING
CONCRETE PAVING
.0
0'
5.00' TYP.
4.00'
TYP.
1.00'
TYP.
1.00'
TYP.
4.00'
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
X
X
X
X
X
X
X
CO
STA:3+64
STA:0+00
STA:1+00
ST
A:
2+
ST
A:
3+
STA:0+33
CO
STA:0+00
STA:1+00
ST
A:
2+
ST
A:
3+
ST
A:
3+
1.5 W
1.5 W
1.5 W
1.5 W
1.5 W
1.5 W
STRM DOG HOUSE
EX SSMH
STRM JB
SS AD #6 (TYPE 1)
SSMH #2
SSMH #1
320 GALLON INTERCEPTOR
SS CO #2
SS CO #1
STRM AD #5 (TYPE 1)
STRM GI #2 (TYPE 2)
STRM GI #3 (TYPE 1)
STRM AD #4 (TYPE 2)
1,500 GALLON INTERCEPTOR
STRM GI #1 (TYPE 1)
387 388 389
STA:0+49
STA:0+00
STRM AD #5 (TYPE 2)
0 10 20
1 INCH = 10 FEET
1. 1" WATER LINE.
2. 1.5" WATER LINE MANIFOLD.
3. 1" GATE VALVE, SEE DETAIL B6/ C-503.
4. WALL MOUNTED 34" HOSE BIB, F5/ C-503.
5. 4" SANITARY SEWER.
6. 6" SANITARY SEWER.
7. 8" SANITARY SEWER.
8. SANITARY SEWER CLEANOUT, SEE DETAIL D9/ C-503.
9. SANITARY SEWER MANHOLE, SEE DETAIL E9/ C-502.
10. 1,500 GALLON SAND-OIL INTERCEPTOR, SEE DETAIL E7/
C-202.
11. 8" PVC STORM DRAIN.
12. 12" PVC STORM DRAIN.
13. 18" PVC STORM DRAIN.
14. STORM DRAIN GRATED INLET, SEE DETAIL B2/ C-502.
15. STORM DRAIN AREA DRAIN WITH 4' CONCRETE COLLAR,
SEE DETAIL E2 & E5/ C-502.
16. STORM DRAIN JUNCTION BOX, SEE DETAIL B6/ C-502.
17. 4" PERFORATED PVC, SEE DETAIL B2/ C-503.
18. 320 GALLON SAND-OIL INTERCEPTOR, SEE DETAIL E7/
C-202.
19. WALL MOUNTED ELECTRIC PRESSURE WASHER, SEE
NOTES BELOW.
KEYED NOTES
GENERAL NOTES:
1. HORIZONTAL AND VERTICAL LOCATIONS OF EXISTING
SANITARY SEWER AND STORM DRAIN LINES ARE
APPROXIMATED BASED ON AVAILABLE RECORD DATA
AND FIELD OBSERVATIONS. PROPOSED SANITARY
SEWER LINE LOCATIONS AND INVERTS ARE BASED ON
THE AVAILABLE DATA. THE CONTRACTOR IS TO VERIFY
THE LOCATIONS OF ALL EXISTING UTILITIES, INCLUDING
SANITARY SEWER, AND IS TO NOTIFY THE ENGINEER
OF ANY DISCREPANCIES BETWEEN AVAILABLE DATA
AND AS-BUILT CONDITIONS.
2. CONTRACTOR SHALL BID AN ADDITIONAL 125 L.F. OF 1
2" WATER DISTRIBUTION LINE TO CONNECT TO THE
NEW 1 12" WATER MANIFOLD AS DESCRIBED IN THE
DEMOLITION PLANS.
2.1. THE INSTALLATION OF 125 L.F. OF WATER LINE
INCLUDES ALL NECESSARY CONSTRUCTION
ACTIVITIES AND MATERIALS REQUIRED FOR
INSTALLATION.
3. CONTRACTOR SHALL COORDINATE UTIILTY
CONNECTIONS TO BUILDINGS WITH MECHANICAL
PLANS.
EX CURB & GUTTER
CURB & GUTTER
STORM DRAIN CATCH BASIN /
AREA DRAIN PER PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
STORM DRAIN LINE
WATER LINE
6" SANITARY SEWER LINE
STORM DRAIN MANHOLE
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
WATER VALVE
HOSE BIB
EX CURB INLET
EX TREE
UTILITY PLAN
C-102
STORM DRAINAGE RUN #1
STORM DRAINAGE RUN #2
SANITARY SEWER RUN #1
SANITARY SEWER RUN #2
NEW ADMINISTRATION
BUILDING
NE
W
M
AI
NT
EN
AN
CE
BU
IL
DI
NG
NEW COVERED VEHICLE
STORAGE
LEGEND AND SYMBOLS
OVERHEAD PARKING
8" SANITARY SEWER LINE
PRESSURE WASHER NOTES:
1. PRESSURE WASHER SHALL BE Mi-T-M, ELECTRIC, WALL
MOUNTED PRESSURE WASHER (CAW-3004-0ME1), OR
APPROVED EQUAL.
2. CONTRACTOR SHALL CONFIRM INSTALLATION
LOCATION WITH CEMETERY STAFF PRIOR TO
INSTALLATION.
3. UNIT SHALL HAVE, OR BE CAPABLE OF THE
FOLLOWING:
· WORKING PRESSURE - 3,000 PSI
· FLOW - 3.9 GPM
· HORESPOWER - 8.0
· REMOTE CONTROL BOX TO CONTROL ON/OFF
· AUTO START/STOP WHEN TRIGGER IS PULLED
· QUICK CONNECT LOW PRESSURE DETERGENT
INJECTOR
· THERMAL RELIEF VALVE
· TIME DELAY SUTDOWN
· 50-FOOT 38" HOSE
· 36-INCH ADJUSTABLE DUAL LANCE WITH INSULATED
TRIGGER GUN.
STORM DRAINAGE RUN #3
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INE ER
X
X
X
X
X
X
CO
CO
387 388 389
FG:382.21
FG:382.00
FG:382.45
FG:383.00
FG:383.00
FG:383.00
FG:383.00
FG:382.60
FG:382.40
FG:382.29
FG:382.07
FG:381.89
FG:381.06
FG:381.19
FG:380.85
FG:380.34
FG:380.07
FG:381.49
FG:381.56
FG:381.15
FG:381.20
FG:381.40
FG:381.08
FG:380.20
FG:380.61
FG:380.60
FG:380.61
FG:380.60
FG:380.40
FG:380.25
FG:380.25
FG:380.75
FG:380.75
FG:380.75 FG:380.89
FG:381.14
FG:380.62
FG:380.52
FG:380.41
FG:380.62
FG:380.62
FG:380.59FL:380.50
FG:380.88
FG:380.55
FG:380.10
FG:380.10
FG:380.60
FG:379.00
FG:379.00
FG:379.25
FG:379.25
FG:379.00
FG:379.00
FG:379.48
FG:379.48
FG:380.45
FG:380.15
FG:380.45
FG:380.50
FG:380.57
FG:380.57
FG:380.57
FG:380.60
FG:380.50
FG:380.07
FL:380.10
FL:379.81
FG:380.06
FG:380.06
FL:380.07
FG:380.03
FL:379.78
FG:380.03
FG:379.04
FG:379.15
FG:379.84
FG:379.53
FG:378.62
FG:378.62
FL:378.37
FG:378.32
FG:378.32
FL:378.32
FG:378.32
FG:378.32
FL:378.32
FG:378.59
FG:378.59
FL:378.34
TC:381.41
TC:381.38
TC:381.02
TC:MATCH EX
TC:MATCH EX
FG:385.50
FG:385.50
FG:383.22
FG:379.83
FG:379.15
FG:379.53
FG:379.04
FG:380.13
FG:380.13
TC:381.25TC:381.25
TC:381.29
TC:381.29
FG:380.50
FG:380.50
FG:380.53
FG:380.53
FG:382.00
FG:382.50
FG:382.50
TW:389.00
TW:387.00
TW:385.50
FG:379.80
0 10 20
1 INCH = 10 FEET
1. MATCH EXISTING ASPHALT PAVING AT SAWCUT LINE
2. APPROXIMATE LIMITS OF EXCAVATION FOR WALL
CONSTRUCTION AND PAD FILL, SEE GENERAL NOTES
BELOW.
3. MATCH EXISTING GRADE WITH CURB.
KEYED NOTES
GENERAL NOTES:
1. THE LIMITS OF DISTURBANCE ALONG THE HILLSIDE IS
SHOWN AS A CONVENIENCE TO THE CONTRACTOR.
ACTUAL LIMITS WILL DEPEND ON MEANS AND
METHODS UTILIZED BY THE CONTRACTOR FOR
EXCAVATION. CONTRACTOR IS TO APPLY
APPROPRIATE MEASURES TO LIMIT EXCAVATION SO AS
NOT TO DISTURB EXISTING BURIALS. AREAS OF
EXCAVATION AND FILL ARE TO BE PROPERLY
BACKFILLED, COMPACTED, AND LANDSCAPED PER THE
LANDSCAPE PLANS.
LEGEND AND SYMBOLS
EX CURB & GUTTER
CURB & GUTTER
CONTOUR MINOR
CONTOUR MAJOR370
STORM WATER CATCH BASIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
FINISHED GRADE
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
EX CURB INLET
EX TREE
GRADING PLAN
C-103
NEW ADMINISTRATION BUILDING
FINISHED FLOOR = 380.60
TOP OF FOOTER = 378.60
NE
W
M
AI
NT
EN
AN
CE
B
UI
LD
IN
G
FI
NI
SH
ED
F
LO
OR
0.
(G
RA
DE
A
T 0.
5% T
OW
AR
D
FL
OOR
DR
AI
NS
TO
P
OF
FO
OTE
R
8.
NEW COVERED VEHICLE STORAGE
FINISHED FLOOR = VARIES
TOP OF FOOTER = 378.62
FG:100.00
TOP OF CURBTC:100.00
FLOW LINEFL:100.00
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
X
X
X
X
X
X
RENOVATED BRICK
STORAGE BUILDING
EMPLOYEE PARKING
VEHICLE WASH AREA
AMIENS AVENUE
SOISSONS AVENUE
CO
CO
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
1. EXPANSION JOINT, SEE DETAIL C8/C-501.
2. CONTRACTION JOINT, SEE DETAIL C5/C-501.
0 10 20
1 INCH = 10 FEET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
JOINTING PLAN
C-104
KEYED NOTES
GENERAL NOTES:
1. CONTRACTOR SHALL PLACE A NON-DOWELED
EXPANSION JOINT AROUND THE PERIMETER OF THE
CONCRETE PAVING.
2. CONTRACTOR SHALL PLACE A DOWELED EXPANSION
JOINT AROUND THE PERIMETER OF THE VALLEY
GUTTER.
LEGEND AND SYMBOLS
EX. CONTOUR MAJOR
EX. CONTOUR MINOR
EX. CURB & GUTTER
EX. SIDEWALK
EX. TREE (TYP.)
EX. MANHOLE
EX. UTILITY BOX
EX. C.M.U. RETAINING WALL
EX. CHAIN LINK FENCING
*SEE SURVEY SHEETS FOR EXISTING CONDITIONS LEGEND
EX. GATE
NEW ADMINISTRATION BUILDING
NE
W
M
AI
NT
EN
AN
CE
B
UI
LD
IN
G
NEW COVERED VEHICLE STORAGE
EXPANSION JOINT
CONTROL JOINT
2 TYP.
2 TYP.
2 TYP.
1 TYP.
1 TYP.
TYP.
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INEER
05/24/2023
1 TYP.
1 TYP.
STORM DRAINAGE RUN 1 PROFILE
VERT. SCALE: 1"=1'
HORIZ SCALE: 1"=10'
0+00 1+00 2+00 3+00
154 LF 15" PVC @ 0.25%
27 LF 15" PVC @ 0.25%
75 LF 15" PVC @ 0.25%
59 LF 12" PVC @ 0.25%
49 LF 8" PVC @ 1.00%
STORM DRAINAGE RUN 2 PROFILE
VERT. SCALE: 1"=1'
HORIZ SCALE: 1"=10'
33 LF 8" PVC @ 1.00%
6" PVC
D
EP
TH
=1
.9 1'
STORM DRAINAGE RUN 3 PROFILE
VERT. SCALE: 1"=1'
HORIZ SCALE: 1"=10'
0+00
49 LF 8" PVC @ 1.00%
0 10 20
1 INCH = 10 FEET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
STORM DRAINAGE PROFILES
C-201
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
SANITARY SEWER RUN #1 PROFILE
VERT. SCALE: 1"=1'
HORIZ SCALE: 1"=10'
0+00 1+00 2+00 3+00
SANITARY SEWER RUN #2 PROFILE
VERT. SCALE: 1"=1'
HORIZ SCALE: 1"=10'
73 LF 6" PVC @ 1.25%
46 LF 6" PVC @ 1.25%
19 LF 8" PVC @ 0.75%141 LF 8" PVC @ 0.75%
43 LF 6" PVC @ 2.12%
0+00
12 LF 4" PVC @ 16.70%
9 LF 4" PVC @ 5.88%
8" PVC
D
EP
TH
1.
0 10 20
1 INCH = 10 FEET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
SANITARY SEWER PROFILES
C-202
GENERAL NOTES:
1. CONTRACTOR SHALL
SCARIFY AND
COMPACT 12" OF
SUBGRADE PER
SPECIFICATION 31 20
00.
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
DETAILS - SITE
C-501
FL
O
W L
IN
E
SCALE: NTS
ROADWAY CROSS SECTIONA2
12" 12"
4"
10" R 10"
14"
1/4" R 1/4" R
24"
5"
LANDSCAPE/PAVEMENT
PER PLAN
SCALE: NTS
MOUNTABLE CURB AND GUTTERD2
EXPANSION JOINT FILLER
WITH SEALANT
GENERAL NOTES:
1. JOINT SHALL BE SAW CUT TO MATCH
EXISTING.
2. MAXIMUM JOINT SPACING SHALL BE 10' O.C.
3. JOINT DEPTH TO BE 1/4 OF PAVEMENT
THICKNESS
SCALE: NTS
CONTRACTION JOINT (TYP.)C5
SCALE: NTS
EXPANSION JOINT (TYP.)C8
CONTINUOUS
REBAR BOTH
WAYS TYP.
PAINT AND GREASE
END OF DOWELS
SMOOTH DOWEL 58" DIA.
@ 18" O.C. 5" 5"
JOINT
GENERAL NOTES:
1. INSTALL MASON SAND ON TOP OF SEALANT
BEFORE SEALANT CURES.
2. ALL EXPANSION JOINTS ARE TO HAVE A 1/4"
TOOLED RADIUS.
SEALANT IS TO BE ROUNDED AS SHOWN
CONCRETE
PAVEMENT
SCALE: NTS
CURB AND GUTTERB5
2.0%
48"
1/4" R1/4" R
10"
5"
LANDSCAPE/PAVEMENT
PER PLAN
SCALE: NTS
VALLEY GUTTERF2
GENERAL NOTES:
1. 3 ROWS OF #4 BARS, CENTERED
AS SHOWN.
2. CONTROL JOINTS CONSISTING
OF 1" DEEP SCORES SHALL BE
PLACED AT 10' INTERVALS O.C.
3. EXPANSION JOINTS SHALL BE
PLACED AT 50' INTERVALS.
4. SLOPED PER ELEVATIONS
SHOWN ON GRADING PLAN.
1.5 : 12 1.5 : 12
1/4" R
CONCRETE PER
SPECIFICATION 32 05 23
CONCRETE PER
SPECIFICATION 32 05 23
SCALE: NTS
CONSTRUCTION JOINT (TYP.)B8
PAINT AND GREASE
END OF DOWELS
SMOOTH
DOWEL 58" DIA.
5" 5"
GENERAL NOTES:
1. ALL CONSTRUCTION
JOINTS ARE TO HAVE A
1/4" TOOLED RADIUS.
1/4" R
12" SCARIFY AND COMPACT
SUBGRADE PER
SPECIFICATIONS
2" SURFACE COURSE COMPACTED
ASPHALT CONCRETE PER
SPECIFICATIONS
10" COMPACTED
AGGREGATE BASE
PER SPECIFICATIONS
2" BASE COURSE COMPACTED
ASPHALT CONCRETE PER
SPECIFICATIONS
TACK COAT
BETWEEN LIFTS
PRIME COAT
MATCH EX.
MATCH EX.
MATCH EX.
10"
COMPACTED
SUBGRADE PER
SPECIFICATIONS
LANDSCAPING
SEE PLANS
MATCH EX
1/4" R
4" COMPACTED
AGGREGATE BASE
PER SPECIFICATIONS
CONCRETE PER
SPECIFICATION 32 05 23
GENERAL NOTES:
1. TWO ROWS OF #4 BARS
CENTERED AS SHOWN.
2. EXPANSION JOINTS SHALL BE
PLACED AT ALL LOCATIONS
WHERE NEW MEETS EXISTING
W/ TWO DOWELS.
1/4" RADIUS AT
EDGES
CONCRETE PAVING PER SPECIFICATION 32 05
23. MEDIUM BROOM FINISH.
5"
5"
4"
SCALE: NTS
CONCRETE PAVEMENTF8
#4 REBAR @ 12" O.C. EACH WAY
AND MUST BE SUPPORTED ON
REINFORCEMENT BAR CHAIRS
WHEN INSTALLED
12" SCARIFY AND COMPACT SUBGRADE PER
SPECIFICATIONS
5" COMPACTED AGGREGATE BASE
PER SPECIFICATIONS
10"
10"X10" THICKENED EDGE W/
(2) #4 BAR CONTINUOUS SEE
GENERAL NOTES.
10"
#4 @ 12" O.C. TO MATCH SLAB
REINFORCEMENT
GENERAL NOTES:
1. TWO ROWS OF #4 BARS
CENTERED AS SHOWN.
2. EXPANSION JOINTS SHALL BE
PLACED AT ALL LOCATIONS
WHERE NEW MEETS EXISTING
W/ TWO DOWELS.
SCALE: NTS
LANDSCAPE CURBF5
GENERAL NOTES:
1. A THICKENED EDGE SHALL BE
PLACED IN THE FOLLOWING
LOCATIONS ONLY:
1.1. ALONG THE PERIMETER OF
THE VALLEY GUTTER.
1.2. AT THE ENTRANCE TO THE
MAINTENANCE FACILITY
ADJOINING THE ASPHALT
PAVING.
12"
6"
FINISHED GRADE (CEMETERY)
TOP OF CURB, MEDIUM
BROOM FINISH
2 ROWS OF CONTINUOUS #4 REBAR
4 " RADIUS TYP.
GENERAL NOTES:
1. EXPANSION JOINTS SHALL BE PLACED AT 50' INTERVALS O.C.
2. CONTROL JOINTS CONSISTING OF 1" DEEP SCORES SHALL BE
PLACED AT 10' INTERVALS O.C.
3. EXPANSION JOINT WITH 2 DOWELS SHALL BE PLACED AT ALL
LOCATIONS WHERE NEW WORK MEETS EXISTING.
COMPACTED
SUBGRADE PER
SPECIFICATIONS
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INE ER
05/24/2023
CONCRETE PAVING PER SPECIFICATION 32 05
23. MEDIUM BROOM FINISH.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
DETAILS - UTILITIES
C-502
NTS
GRATED INLETB2
NTS
PRECAST CONCRETE SANITARY SEWER MANHOLEE9
NTS
AREA DRAIN (TYPE 1)E2
CONCRETE COLLAR
REINFORCED WITH #4
HOOPS AND #3 CLOSED
TIES SPACED @ 6" O.CO
FINISHED GRADE
GROUT
PRE CAST BASE SLAB WITH #4
BARS AT 12" O.C. EACH WAY.
6" MIN
CONCRETE FILL
5" PRECAST
CONCRETE WALL
PER PLAN
10" 6"
VARIES
GENERAL NOTES:
1. CONTRACTOR SHALL SCARIFY AND
COMPACT 12" OF SUBGRADE PER
SPECIFICATION 31 20 00.
2. PRECAST STRUCTURE WALLS TO HAVE
#4 BARS AT 8" O.C. EACH WAY.
3. STEPS SHALL BE PLACED DIRECTLY
OVER THE OUTLET OF THE STRUCTURE.
4. STEEL STEPS SHALL BE INSTALLED IN
STRUCTURES THAT EXCEED 36" IN
DEPTH AND SHALL CONFORM TO CITY
OF LOS ANGELES STANDARD PLAN
S-348-1.
5. STEPS SHALL BE CAST IN PLACE AT THE
TIME OF FABRICATION WITH 15"
MAXIMUM SPACING BETWEEN STEPS.
PROVIDE KEYWAY
GENERAL NOTES:
1. CONTRACTOR SHALL CONSTRUCT
MANHOLE PER LOS ANGELES COUNTY
DEPARTMENT OF PUBLIC WORKS
STANDARD DETAIL 2003-2, OR MOST
CURRENT PUBLICATION.
2. CONTRACTOR SHALL SCARIFY AND
COMPACT 12" OF SUBGRADE PER
SPECIFICATION 31 20 00.
12" MIN WIDTH
8" MIN
OUTLET ADAPTERS
SEE PLANS
GENERAL NOTES:
1. CONTRACTOR SHALL SCARIFY AND
COMPACT 12" OF SUBGRADE PER
SPECIFICATION 31 20 00.
COMPACTED BEDDING PER
SPECIFICATION 31 20 00
NYLOPLAST INLINE DRAIN,
MEETS H-20 TRAFFIC RATING.
*OR APPROVED EQUAL
12" MINIMUM
ADAPTER ANGLES
VARIABLE 0° - 360°
ACCORDING TO
PLANS
12" MIN WIDTH
8"
6"
12" MIN
SEE PLANS
OUTLET ADAPTER GENERAL NOTES:
1. CONTRACTOR SHALL SCARIFY AND
COMPACT 12" OF SUBGRADE PER
SPECIFICATION 31 20 00.
2. CONTRACTOR SHALL BACKFILL WITH
DRAINAGE ROCK WRAPPED IN FILTER
FABRIC TO 12" ABOVE THE UPPER MOST
PIPE.
3. CONTRACTOR SHALL DRILL 12" DIAMETER
HOLES SPACED AT 9" O.C. IN A
CYLINDRICAL PATTERN FROM THE
BOTTOM OF THE STRUCTURE TO 6"
ABOVE THE UPPER MOST PIPE.
18" MINIMUM
NTS
AREA DRAIN (TYPE 2)E5
24" INTEGRATED DUCTILE IRON FRAME
AND GRATE TO MATCH BASIN O.D.
18" INTEGRATED DUCTILE IRON FRAME
AND GRATE TO MATCH BASIN O.D.
NYLOPLAST DRAIN BASIN
MEETS H-20 TRAFFIC RATING.
*OR APPROVED EQUAL
SCALE: NTS
STORM DRAIN JUNCTION BOXB6
MANHOLE FRAME AND COVER PER
APWA STANDARD PLAN 210.
CONTRACTOR TO MATCH EXISTING
JUNCTION BOXES.
FINISHED GRADE
GROUT5" PRECAST
CONCRETE WALL
PER PLAN
18" ECCENTRIC
COLLAR
GRADE RINGS AS REQUIRED
48"
DIA.
GENERAL NOTES:
1. CONTRACTOR SHALL SCARIFY AND
RECOMPACT 12" OF SUBGRADE
PER SPECIFICATION 31 20 00.
2. PRECAST STRUCTURE SHALL HAVE
#4 BARS 8" O.C. EACH WAY.
3. THE TOP OF THE MANHOLE AND
THE STEPS SHALL BE PLACED
DIRECTLY OVER THE OUTLET OF
THE STRUCTURE.
4. STEEL STEPS SHALL BE INSTALLED
IN STRUCTURES THAT EXCEED 36"
IN DEPTH AND SHALL CONFORM TO
STANDARD PLAN S-348.
5. STEPS SHALL BE CAST IN PLACE
AT THE TIME OF FABRICATION
WITH 15" MAXIMUM SPACING
BETWEEN STEPS.
STEPS
1/2" WASHED DRAINAGE
ROCK WRAPPED IN 8 OZ NON
WOVEN FILTER FABRIC.
PRE CAST BASE SLAB WITH #4
BARS AT 12" O.C. EACH WAY.
6" MIN
CONCRETE FILL
PROVIDE KEYWAY
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
REPLACE STORAGE BUILDING
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
DETAILS - UTILITIES
C-503
SCALE: NTS
SEWER LATERAL CONNECTIONB4
WYE BRANCH
WYE BRANCH
8 BEND 4" LATERAL TO
BUILDING
SANITARY SEWER MAIN
SANITARY SEWER MAIN
4" LATERAL TO
BUILDING
8 BEND
PLANELEVATION
NTS
STANDARD UTILITY TRENCHF2
6"
MIN.
6"
MIN.
4" MIN.
4" MIN.
GENERAL NOTES:
1. EXCAVATE FOR BELLS OR
HUBS SO FULL LOAD IS
CARRIED BY PIPE BARRELS.
SHAPE TO FIT BELL AND HUB,
AND THOROUGHLY COMPACT
UNDER PIPE. SEE NOTE 1.
COMPACTED BEDDING PER
SPECIFICATION 31 20 00
ENGINEERED FILL PER
SPECIFICATION 31 20 00
FINISHED GRADE OR PAVEMENT
VARIES.
WARNING TAPE PER SPECIFICATION
33 10 00 & 33 40 00
STRUCTURE FOOTING
PER STRUCTURAL DRAWINGS,
SHOWN FOR COORDINATION
PURPOSES ONLY.
1/2" WASHED DRAINAGE
ROCK WRAPPED IN 8 OZ NON
WOVEN FILTER FABRIC.
1'
4"Ø PERFORATED PVC PIPE.
VARIES
SCALE: NTS
FOUNDATION DRAINB2
12"
GENERAL NOTES:
1.…