LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 1 of 6.pdf

PDF 10 MB Posted

Attached to
Y1EB--Los Angeles CA 898 -034 Maint, 036 FCA (VA-24-00060981)
Solicitation number
36C78624B0023
Issued by

About this file

This document appears to be a set of amended drawings for the Los Angeles, CA 898-034 Maintenance and 036 FCA (VA-24-00060981) contract opportunity with the Department of Veterans Affairs National Cemetery Administration. The solicitation number is 36C78624B0023. The document provides revised technical drawings related to the project requirements. It does not appear to contain details on the specific products or services required, response dates, pricing, or other key solicitation information. This appears to be a technical attachment provided as part of the overall solicitation package.

View the file

Other files

File Type Posted
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 5 of 6.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 4 of 6.pdf PDF
RFIs -AE-COR.docx DOCX document
Amendment 0002.docx DOCX document
LANC Combined Specifications 4 of 4 Rev 001 6.20.24.pdf PDF
LANC Combined Specifications 3 of 4 Rev 001 6.20.24.pdf PDF
LANC Combined Specifications 2 of 4 Rev 001 6.20.24.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 2 of 6.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 3 of 6.pdf PDF
LANC Combined Specifications 1 of 4 Rev 001 6.20.24.pdf PDF
LANC FCA Deficiencies Bid Package Ammended Drawings - Reduced - 6 of 6.pdf PDF
S04 LA Sign In Roster.pdf PDF
S01 LA 0001 Amendment.docx DOCX document
36C78624B0023.docx DOCX document
231030 LANC 898-Multi MX - FCA IFB Scope of Work.docx DOCX document
S02 Final LANC Combined Specifications -4 of 4.pdf PDF
231030 LANC 898-036 FCA Bid Docs 5 of 5.pdf PDF
231030 LANC 898-036 FCA Bid Docs 4 of 5.pdf PDF
231030 LANC 898-034 MX Bid Docs 3 of 5.pdf PDF
231030 LANC 898-036 FCA Bid Docs 2 of 5.pdf PDF
S02 Final LANC Combined Specifications-1 of 4.pdf PDF
P07 Wage Determination LA.pdf PDF
231030 LANC 898-036 FCA Bid Docs 3 of 5.pdf PDF
36C78624B0023_2.docx DOCX document
231030 LANC 898-034 MX Bid Docs 5 of 5.pdf PDF
231030 LANC 898-034 MX Bid Docs 4 of 5.pdf PDF
231030 LANC 898-036 FCA Bid Docs 1 of 5.pdf PDF
S02 Final LANC Combined Specifications -3 of 4.pdf PDF
S02 Final LANC Combined Specifications-2 of 4.pdf PDF
231030 LANC 898-034 MX Bid Docs 1 of 5.pdf PDF
231030 LANC 898-034 MX Bid Docs 2 of 5.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

COVER

G-001

SITE LOCATION MAP

SCALE: NTS N

SHEET INDEX

SHEET

NO.

DRAWING

NO. SHEET TITLE

1 G-001 COVERSHEET

DEPARTMENT OF VETERANS AFFAIRS

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

NCA PROJECT NO. 898CM3036

950 S Sepulveda Blvd, Los Angeles, CA 90049

SITE LOCATION AND ACCESS MAP

SCALE: NTS N

CODE OF CONDUCT

1. BURIAL CEREMONIES WILL BE SCHEDULED THROUGHOUT THE COURSE OF THIS PROJECT. COORDINATE

DAILY ACTIVITIES WITH THE CEMETERY DIRECTOR OR HIS APPROVED REPRESENTATIVE TO

ACCOMMODATE SCHEDULED BURIALS (COLUMBARIUM WALLS). CONTRACTOR SHALL OBTAIN THE

SCHEDULE FOR THE NEXT DAY SERVICES PRIOR TO THE CLOSE OF BUSINESS EACH DAY. ALLOWABLE

WORK TO BE DETERMINED BY THE CEMETERY DIRECTOR.

2. BECAUSE OF THE SENSITIVE NATURE OF THE CEMETERY SITE, CONTRACTOR SHALL MAINTAIN EACH WORK AREA IN A CLEAN AND ORDERLY APPEARANCE. TRASH AND WASTE MATERIALS SHALL BE STORED IN APPROVED CONTAINERS AND ROUTINELY DISPOSED OFF-SITE. CLEANUP SHALL BE REQUIRED AT THE

END OF EACH DAY AND/OR MORE FREQUENTLY AS REQUIRED.

3. THE CONTRACTORS STAFF AND SUBCONTRACTORS STAFF SHALL NOT: DRESS IN SLEEVELESS SHIRTS OR SHORT PANTS, WEAR CLOTHING WITH INAPPROPRIATE LOGOS, PLAY MUSIC, TALK LOUD, PLACE

PERSONAL ITEMS ON HEADSTONES, LEAN AGAINST OR SIT ON HEADSTONES.

4. THE EFFECT OF WORK ON PUBLIC ACCESS SHALL BE MINIMAL AND SHALL BE COORDINATED WITH THE

CEMETERY DIRECTOR. ANY ALTERED PUBLIC TRAFFIC ROUTES SHALL BE WELL DEFINED WITH

PROFESSIONALLY MADE SIGNAGE AND/OR OTHER APPROVED CONVENTIONAL METHODS.

5. DO NOT WORK UPON NOR STORE ANY MATERIALS ON OCCUPIED COLUMBARIUM WALLS. ALL EFFORT

WILL BE MADE TO MAINTAIN DISTANCE FROM OCCUPIED COLUMBARIUM WALLS.

1. TOPOGRAPHIC INFORMATION PROVIDED BY SURVEY PERFORMED BY ATC DESIGN GROUP. THE

GENERAL CONTRACTOR SHALL VERIFY ALL SURVEY INFORMATION.

2. THE BASIS OF BEARINGS FOR THE SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, ZONE 5 CCS83 (2017.5 EPOCH) AS DETERMINED LOCALLY BY FIELD OBSERVED TIES TO CONTINUOUS OPERATING REFERENCE STATION (CORS) "BLSA" HAVING A CALIFORNIA COORDINATE VALUE OF 1ST ORDER

ACCURACY OR BETTER.

3. THE EXISTING UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE INFORMATION.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL UTILITIES PRIOR TO BEGINNING ANY WORK. IF UTILITIES OTHER THAN THOSE SHOWN HEREON ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY AND TAKE APPROPRIATE MEASURES TO

PROTECT THE LINE(S) AND ENSURE CONTINUED SERVICE. DAMAGE CAUSED TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

THE CONTRACTOR SHALL VERIFY THE CONNECTION POINTS OF NEW UTILITIES TO EXISTING UTILITIES

PRIOR TO BEGINNING CONSTRUCTION.

4. THE CONTRACTOR SHALL INSTALL TREE PROTECTION BARRICADES PRIOR TO BEGINNING EARTHWORK

OPERATIONS.

5. THE CONTRACTOR SHALL NOTIFY THE COR IF UNSUITABLE MATERIAL IS DISCOVERED PRIOR TO

BEGINNING ANY REMOVAL OPERATION. (SEE SPECIFICATION SECTION 31.20.00)

6. THE CONTRACTOR SHALL STABILIZE ALL DISTURBED AREA WITH SOD OR MULCH, NOT SHOWN FOR ASPHALT OR CONCRETE, WITHIN LIMITS OF DEMOLITION AND PROPOSED WORK. THIS INCLUDES

STAGING AREA AND LAYDOWN AREAS.

7. CONTRACTOR SHALL GRADE ALL DISTURBED AREAS TO DRAIN FOR POSITIVE FLOW PRIOR TO FINAL

APPROVAL.

8. THE DESIGN ADEQUACY AND SAFETY OF ALL BRACING, SHORING AND TEMPORARY SUPPORTS, ETC. IS

THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

9. IN PERFORMING CONSTRUCTION OBSERVATION VISITS TO THE JOB SITE, THE ENGINEER SHALL HAVE NEITHER CONTROL OVER NOR RESPONSIBILITY FOR THE CONTRACTOR'S MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES IN PERFORMING THE WORK.

10. THE CONTRACTOR'S MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES IN PERFORMING THE WORK IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR, WHO IS ALSO RESPONSIBLE FOR COMPLYING WITH ALL HEALTH AND SAFETY PRECAUTIONS AS REQUIRED BY ANY REGULATORY AGENCY.

11. THERE SHALL BE AT ALL TIMES, WHEN WORK IS BEING DONE, A COMPETENT PERSON WHO IS APPRISED OF THE CONDITION AND PROGRESS OF ALL AREAS OF WORK ON SITE. THIS COMPETENT PERSON SHALL BE ABLE TO SPEAK FOR AND ACT IN THE BEHALF OF THE CONTRACTOR. HE SHALL BE AWARE AND KNOWLEDGEABLE OF ALL THE SAFETY CONCERNS ON THE JOB SITE. HE SHALL BE EMPOWERED TO

IMMEDIATELY AND EFFECTIVELY MITIGATE THE ACTIONS OF ANY WORKMAN ON SITE.

12. CONTRACTOR SHALL PREPARE AND SUBMIT A WELDING PLAN TO THE COR PRIOR TO PERFORMING ANY FIELD WELDING SHOULD IT BE REQUIRED. FOLLOWING APPROVAL ALL WELDS SHALL BE PERFORMED IN

ACCORDANCE WITH THE APPROVED PLAN.

GENERAL NOTESPROJECT TEAM

ARCHITECT / ENGINEER

VALI COOPER INTERNATIONAL, LLC

DENVER, CO 80249

CONTACT: JORDAN VANDERMEER

JORDAN.VANDERMEER@VALIINT.COM

720-799-1035

SURVEYOR

ATC DESIGN GROUP

ESCONDIDO, CA 92029

CONTACT: RYAN POST

RPOST@ATCDESIGNGROUP.COM

760-738-8800

SITE OWNER

VA NCA

LOS ANGELES NATIONAL CEMETERY

CONTACT: TEMOC MEZA DAVILA

CUAUHTEMOC.MEZADVAILA@VA.GOV

808-532-4650

GEOTECH

TERRACON

TUSTIN, CA 92780

CONTACT: S. (RAJ) PIRATHIVIRA

RAJ.PIRATHIVIRAJ@TERRACON.COM

949-383-1990

HISTORIC PRESERVATION

TERRACON

JACKSONVILLE, FL 32256

CONTACT: MORGAN GRANGER

MORGAN.GRANGER@TERRACON.COM

339-210-9417

HAZARDOUS ABATEMENT

TERRACON

TUSTON, CA 92780

CONTACT: CHRIS BLAKE

CHRIS.BLAKE@TERRACON.COM

949-864-2060

FIRM PANEL

SCALE: NTS N

G-101

WILSHIRE BLVD

V-101 V-401

CA STATE ROUTE 2

HIGHWAY 10

HIGHW

AY 405

FEDERAL AVE

V-402 V-403 V-404

C-101 C-102

C-401 C-402 C-403 C-404 C-405 C-406 C-407

C-501 C-502 C-503 C-504

SITE ACCESS, FENCING, STAGING AND PHASING PLAN

V-405 V-406 V-407 V-408 V-409 V-410

CD101

CD401

CD402

CD403

CD404

CD405

CD406

CD407

CD408

CD409

EXISTING CONDITIONS KEY

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

EXISTING CONDITIONS - ENLARGED

DEMOLITION PLAN - FLOWER WATER STATIONS, SITE SIGNAGE & SECTION MARKERS (BASE BID)

ENLARGED DEMOLITION PLAN - DUMPSTER AND SPOILS AREA (BASE BID)

ENLARGED DEMOLITION PLAN - HISTORIC FRONT ENTRY (BASE BID)

ENLARGED DEMOLITION PLAN - SOUTHERN CHAIN LINK FENCING (BASE BID)

ENLARGED DEMOLITION PLAN - NORTHERN FENCING (OPTION 2)

ENLARGED DEMOLITION PLAN - FULL DEPTH ASPHALT REMOVAL (BASE BID)

ENLARGED DEMOLITION PLAN - DRAINAGE CANAL (BASE BID)

SITE PLAN - ROADWAY REHABILITATION (BASE BID)

HISTORIC PRESERVATION (BASE BID)

ENLARGED SITE PLAN - DUMPSTER PAD AND SPOILS AREA (BASE BID)

ENLARGED SITE PLAN - SPANISH AMERICAN MONUMENT FENCING (BASE BID)

ENLARGED SITE PLAN - PRIVACY FENCING AT WATER VALVES (BASE BID)

DETAILS - SITE

DETAILS - CHAIN LINK & COMPOSITE FENCING

DETAILS - FLOWER WATER STATIONS

DETAILS - FRONT ENTRY GATE

LOS ANGELES NC

HISTORIC LOS ANGELES NC

FIRM PANEL

SCALE: NTS N

G-102 OVERALL SITE KEY

HD101 HAZARDOUS MATERIALS ABATEMENT - LEAD BASED PAINT

T-102 SITE PLAN - SECURITY SYSTEM (BASE BID)

ENTRY GATE PLAN (BASE BID)

T-101 KEYLESS ENTRY (BASE BID)

T-501 DETAILS - SECURITY SYSTEM

ENLARGED DEMOLITION PLAN - SOUTHERN ORNAMENTAL FENCING (BASE BID)

ENLARGED DEMOLITION PLAN - EASTERN ORNAMENTAL FENCING (BASE BID)

ENLARGED DEMOLITION PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)

ENLARGED DEMOLITION PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)

CD410

CD411

CD412 ENLARGED DEMOLITION PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)

ENLARGED DEMOLITION PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)

C-408 C-409 C-410 C-411

SITE PLAN - FLOWER WATER STATION & NEW SITE SIGNAGE (BASE BID)

C-201

ENLARGED SITE PLAN - SOUTHERN CHAIN LINK FENCING

ENLARGED SITE PLAN - NORTH FENCING (OPTION 2)

ENLARGED SITE PLAN - SOUTHERN ORNAMENTAL FENCING

ENLARGED SITE PLAN - EASTERN ORNAMENTAL FENCING (BASE BID)

ENLARGED SITE PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)

ENLARGED SITE PLAN - EASTERN ORNAMENTAL FENCING (OPTION 1)

ENLARGED SITE PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)

ENLARGED SITE PLAN - WESTERN ORNAMENTAL FENCING (OPTION 3)

C-505 C-506 C-507 C-508

DETAILS - ORNAMENTAL FENCING

DETAILS - ORNAMENTAL FENCING

DETAILS - SIGNAGE

E-101

TELECOM ROOM (BASE BID)E-102

DETAILS - ELECTRICAL (BASE BID)E-501

ELECTRICAL SCHEDULE (BASE BID)E-701

T-502 DETAILS - SECURITY SYSTEM

T-503 DETAILS - SECURITY SYSTEM

C-412

ENLARGED SITE PLAN - HISTORIC FRONT ENTRY (BASE BID)

LD401

ARCHITECTURAL DEMOLITION AND REMODEL PLANS (BASE BID)

CG402 ENLARGED EROSION PLAN - DUMPSTER AND SPOILS AREA (BASE BID)

CG401 ENLARGED EROSION PLAN - PRIVACY FENCING AT WATER VALVES (BASE BID)

CG101 EROSION & TREE PROTECTION GENERAL NOTES AND DETAILS

ENLARGED GRADING PLAN - DUMPSTER AND SPOILS AREA (BASE BID)C-413

C-509

DETAILS - SITE

DETAILS - MATERIAL STORAGE BINS

DETAILS - MATERIAL STORAGE BINS & GENERAL REINFORCING

C-510 C-511

C-512 DETAILS - MATERIAL STORAGE BIN ROOFING

ENLARGED FOUNDATION PLAN - MATERIAL STORAGE BINS (BASE BID)C-414

HISTORIC PRESERVATION (BID OPTION 4)C-202

DETAILS - FENCE CURBING

ENLARGED DEMOLITION PLAN - NORTHERN FENCING PHOTOGRAPHS (OPTION 2)

CD413

LD402

IRRIGATION DEMOLITION PLAN (OPTION 2)

LI401

IRRIGATION DEMOLITION PLAN (OPTION 3)

LI402

IRRIGATION PLAN (OPTION 2)

LI501

IRRIGATION PLAN (OPTION 3)

LADSCAPE DETAILS77

A-101

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

1 REV. 001 - AMMENDED DRAWINGS 6/07/2024

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering G-101

SITE ACCESS, FENCING,

STAGING AND PHASING PLAN

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INEER

04/21/2023

1 REV. 001 - AMMENDED DRAWINGS 6/07/2024

0 0 0

ON SAFETY

ZERO

Department of Veterans Affairs

PAINTED BORDER

MEMBER BLACK ENAMEL

2" X 4" FRAME AND BRACES

IN SAME PLANE

METAL FACE

STRETCH METAL FACE

TIGHT, TURN OVER FRAME

AND SECURE WITH FLAT

HEAD DEFORMED NAILS

LETTERING TO BE

HELVETICA STYLE 5"

HIGH

METAL FACE WHITE

ENAMEL

LETTERING TO BE

HELVETICA STYLE 3"

HIGH TO BE CENTERED

HORIZONTALLY

2" X 4" FRAME AND

BRACE IN BACK

LETTERING TO BE

HELVETICA STYLE 2" HIGH

TO BE CENTERED

HORIZONTALLY

LETTERING TO BE

HELVETICA STYLE 1-1/2"

HIGH TO BE CENTERED

HORIZONTALLY

4" X 4" POSTS

PAINTED WHITE

BORDER MEMBER

PAINTED BLACK

BACKGROUND TO BE

PAINTED WHITE

LETTERING TO BE

HELVETICA STYLE 1"

HIGH TO BE CENTERED

HORIZONTALLY

LETTERING TO BE

HELVETICA STYLE 1-1/2"

HIGH TO BE CENTERED

HORIZONTALLY

SURROUNDING BORDER TO

BE BLUE

CENTER TO BE WHITE

8'-8"

6"

1-1/2" 3" 5" 2" 5" 5" 3" 2"

1-1/2"

4'-0" MIN.

3"

6"

9"

6"

3" 2" 3"

6"

ALL LETTERING TO BE

PAINTED BLACK WITH

EXCEPTION OF PROJECT

TITLE WHICH IS TO BE BLUE

NOTE:

ANY SEAM IN METAL TO BE

FLAT SEAM - SEAMS TO BE

HORIZONTAL AND OCCUR

BETWEEN LINES OF

LETTERING.

SECTION ON CENTER

4'-0"

BRACING

3'-0"

VARIES

3'-0"

BLUE

BLUE

OUTLINE

WITH WHITE

INTERIOR

BLUE

WHITE

RED

RED

2"

2"

2"

1-3/4"

2"

WOOD STRIPS

BRACING

4" X 4" POST IF SIGN IS

INSTALLED ON GRADE

FIN. GRADE

SCALE: NTS

SAFETY SIGND8

SCALE: NTS

PROJECT SIGNB6

VARIES;

AVERAGE 3'-0"

LEGEND AND SYMBOLS

CONSTRUCTION STAGING AREA

PROJECT & SAFETY SIGNAGE

CONSTRUCTION FENCE

ACCESS / HAUL ROUTE

PROJECT SIGN;

SEE DETAIL B6

THIS SHEET

SAFETY SIGN;

SEE DETAIL D8

THIS SHEET

CONSTRUCTION

FENCING WITH

LOCKABLE 20'

ACCESS GATE ACCESS/HAUL

ROUTE

ALTERNATIVE

CONSTRUCTION

STAGING AREA

BASE BID:

BASE BID WORK SHALL BE COMPLETED IN ACCORDANCE WITH

THE FOLLOWING. ALL ITEMS NOT SPECIFICALLY MENTIONED

SHALL BE COMPLETED AT ANY TIME THROUGHOUT THE

PERIOD OF PERFORMANCE.

1. FLOWER WATER STATIONS & ROADWAY SIGNAGE SHALL

BE CONSTRUCTED IN TWO PHASES.

· PHASE 1 - ALL ITEMS SOUTH OF CONSTITUTION AVE.

· PHASE 2 - ALL ITEMS NORTH OF CONSTITUTION AVE.

2. ROADWAY FOG SEAL SHALL BE COMPLETED AFTER THE

COMPLETION OF THE FOLLOWING:

2.1. DUMPSTER AND SPOILS AREA.

2.2. FLOWER WATER STATIONS.

2.3. SITE SIGNAGE.

2.4. DRAINAGE CANAL.

2.5. HISTORIC FRONT ENTRANCE.

2.6. FENCING REPLACEMENT.

BID OPTION 1:

BID OPTION 1 SHALL BE COMPLETED CONCURRENTLY WITH

THE BASE BID AND SHALL NOT BE COMPLETED

CONCURRENTLY WITH BID OPTIONS 2 & 3 WITHOUT WRITTEN

PERMISSION FROM THE COR.

BID OPTION 1 MAY BE COMPLETED IN ONE PHASE.

BID OPTION 2:

BID OPTION 2 SHALL BE COMPLETED CONCURRENTLY WITH

THE BASE BID AND SHALL NOT BE COMPLETED

CONCURRENTLY WITH BID OPTIONS 1 & 3 WITHOUT WRITTEN

PERMISSION FROM THE COR.

BID OPTION 2 SHALL BE COMPLETED IN SECTIONS NO

GREATER THAN 400 L.F. AND SHALL BE START/STOP AT

NEIGHBORING PROPERTY CORNERS.

BID OPTION 3:

BID OPTION 3 SHALL BE COMPLETED CONCURRENTLY WITH

THE BASE BID AND SHALL NOT BE COMPLETED

CONCURRENTLY WITH BID OPTIONS 1 & 2 WITHOUT WRITTEN

PERMISSION FROM THE COR.

BID OPTION 3 MAY BE COMPLETED IN ONE PHASE.

BID OPTION 4:

BID OPTION 4 SHALL BE COMPLETED CONCURRENTLY WITH

THE BASE BID.

PHASING NOTES

SEE

ENLARGEMENT

BELOW

ACCESS/HAUL ROUTE

EXISTING GROUNDS

CONTRACTOR YARD

TEMPORARY NCA

MAINTENANCE

AREA (130x270')

8' TALL CONSTRUCTION

PRIVACY FENCE PER

SPECIFICATIONS WITH

LOCKABLE 20' ACCESS GATE.

FENCING TO BE REMOVED AT

THE COMPLETION OF THE

PROJECT

APPROXIMATE LOCATION OF THE

EXISTING 1" DOMESTIC WATER LINE

24x60 OFFICE TRAILER

TEMPORARY MAINTENANCE YARD NOTES:

1. TEMPORARY MAINTENANCE YARD SHALL BE FULLY FUNCTIONAL PRIOR TO

CONSTRUCTION AT THE MAINTENANCE FACILITY.

2. CONTRACTOR SHALL RELOCATE THE EXISTING FURNITURE & TOOLS IN THE

MAINTENANCE COMPLEX TO THE TEMPORARY MAINTENANCE YARD.

2.1. CONTRACTOR SHALL MOVE THE TOOLS BACK TO THE COMPLETED

MAINTENANCE YARD AT THE COMPLETION OF THE PROJECT

2.2. CONTRACTOR SHALL DISPOSE OF THE EXISTING FURNITURE AT THE

COMPLETION OF THE PROJECT.

3. TEMPORARY MAINTENANCE YARD SHALL REMAIN UNTIL THE COMPLETE TURNOVER

OF THE MAINTENANCE FACILITY.

4. CONTRACTOR SHALL PROVIDE ONE 24' X 60' OFFICE TRAILER WITH TWO OFFICES

WITHIN THE TEMPORARY MAINTENANCE AREA AND ALL REQUIRED

APPURTENANCES.

4.1. OFFICE TRAILER HAVE A PRE-WIRED, DEDICATED ELECTRICAL PANEL.

4.1. TRAILER SHALL HAVE WINDOW AND DOOR SECURITY.

4.2. CONTRACTOR SHALL PROVIDE DATA TO THE TRAILER AT NO ADDITIONAL COST

TO THE GOVERNMENT.

4.2.1. EXISTING DATA IS LOCATED WITHIN THE IT ROOM AT THE RESTROOM/IT

BUILDING.

4.2.2. DATA FIBER SHALL BE ROUTED UNDERGROUND. ROUTING TO BE

APPROVED BY THE COR PRIOR TO INSTALLATION

4.2.3. FIBER SHALL BE 12SM FIBER OPTIC.

5. CONTRACTOR SHALL PROVIDE A WATER SPIGOT BETWEEN THE WORKSHOP

CONEXES.

6. CONTRACTOR SHALL PROVIDE TWO PORTACOOL JETSTREAM 250 (OR APPROVED

EQUAL) EVAPORATIVE COOLERS.

7. CONTRACTOR SHALL RELOCATE THE EXISTING HAZARDOUS MATERIALS STORAGE

LOCKER LOCATED AT THE EXISTING MAINTENANCE YARD. AT THE COMPLETION OF

THE PROJECT, THE CONTRACTOR SHALL MOVE THE LOCKER BACK TO THE

MAINTENANCE YARD.

8. CONTRACTOR SHALL PROVIDE ONE DOUBLE WALL DIESEL FUEL TANK WITH PUMP

AND DISPENSER WITH A HOLDING CAPACITY OF 500 GALLONS MINIMUM. THE

CONTRACTOR IS NOT RESPONSIBLE FOR PROVIDING FUEL.

9. CONTRACTOR SHALL PROVIDE ONE 40' CONEX (END OPENING) FOR STORAGE, NO

LIGHTING OR POWER IS REQUIRED.

10. CONTRACTOR SHALL PROVIDE TWO 40' CONEXES (SIDE OPENING ) WITH

PRE-WIRED LIGHTING AND POWER TO BE USED AS TEMPORARY WORKSHOPS.

10.4. EACH CONEX SHALL BE OUTFITTED WITH A MINIMUM OF (4) FOUR LED LIGHTS

TO MEET THE MINIMUM LIGHTING REQUIREMENT OF 40 FT/CANDLE.

10.5. EACH CONEX SHALL HAVE A MINIMUM OF (6) SIX PRE WIRED DUPLEX OUTLETS.

10.6. EACH CONEX SHALL HAVE A DEDICATED 125 AMP, 3 CIRCUIT BREAKER PANEL.

ALL GROUNDING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 70, AND ALL

GOVERNING CODES AND STANDARDS.

11. CONTRACTOR SHALL PROVIDE ONE THREE STATION RESTROOM/SHOWER COMBO

TRAILER.

11.1. COMBO TRAILER SHALL HAVE A MINIMUM OF ONE SHOWER.

11.1. COMBO TRAILER HAVE A PRE-WIRED, DEDICATED ELECTRICAL PANEL.

11.2. CONTRACTOR SHALL PROVIDE FIVE LOCKERS INSIDE OF THE SHOWER ROOM.

11.3. A MINIMUM OF ONE RESTROOM SHALL BE ABA ACCESSIBLE.

11.4. HOT WATER SHALL BE INCORPORATED.

11.5. CONTRACTOR SHALL PROVIDE SEWAGE HOLDING TANK (S), AND IS

RESPONSIBLE FOR SCHEDULED CLEANOUTS AT NO ADDITIONAL COST TO THE

GOVERNMENT.

11.6. CONTRACTOR SHALL CONNECT TRAILER TO THE EXISTING DOMESTIC

WATERLINE AVAILABLE ON-SITE.

12. CONTRACTOR SHALL PROVIDE A MAIN ELECTRICAL PANEL FOR THE TEMPORARY

MAINTENANCE YARD AT A RATE OF 250 AMPS. ALL GROUNDING SHALL BE PROVIDED

IN ACCORDANCE WITH NFPA 70, AND ALL GOVERNING CODES AND STANDARDS.

12.1. POWER SHALL BE PROVIDED FROM THE EXISTING SWBD-505.

12.2. POWER SHALL BE ROUTED UNDERGROUND.

40' STORAGE CONEX

(2) 40' WORKSHOP CONEX

W/ POWER & LIGHTS

DIESEL STORAGE TANK

HAZARDOUS MATERIALS LOCKER

EXISTING STORAGE CONEX

THREE STATION RESTROOM TRAILER

WITH SHOWER. (TWO TOILETS AND

ONE TOILET SHOWER COMBO)

CONTRACTOR

STAGING AREA

EXISTING FENCING

SWBD-505 LOCATION

DATA ACCESS LOCATION

UNDERGROUND DATA FIBER

FIBER SHALL BE INSTALLED

ADJACENT TO THE EXISTING

CURB UNDER THE ASPHALT

PAVING.

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

0 150 300

1 INCH = 150 FEET

OVERALL SITE KEY

G-102

SEE SHEET CD401,

C-402 & C-413

(BASE BID)

SEE SHEET C-401

(BASE BID)

SEE SHEET CD403

(BASE BID)

SEE SHEET CD404 & C-403

(BASE BID)

SEE SHEET CD407 & C-407

(BASE BID)

SEE SHEET CD410,CD411 & C-410

(BID OPTION 2)

TOUL AVE.

CHATEAU THIERRY AVE.

MARNE AVE.

SAINT MIHIEL AVE.

MEUSE AVE.

TO

U

L

AV

E.

C O

N

ST

IT

U

TI

O

N A

VE

SA

N

TI

AG

O D

R

SA

N

TI

AG

O D

R

AP

PO

M O

TT

O

X D

R

AMIENS AVE.

SOISSONS AVE.

ARGONNE AVE.

GETTYSBURG AVE.

GETTYSBURG AVE.

SAN JUAN HILL AVE.

BUENA VISTA AVE.

ANTIETAM AVE.

LO

O

KO

UT

D R.

BE

LL

EA

U

W O

O D

D R

BE

LL

EA

U

W O

O D

D R

SH

IL

O H

DR

SEE SHEET CD408 & C-408

(BID OPTION 1)

SEE SHEET CD405 & C-405

(BASE BID)

SEE SHEET CD409 & C-409

(BID OPTION 1)

SEE SHEET CD402 &C-413

(BASE BID)

SEE SHEET CD402

(BASE BID)

SEE SHEET CD402

(BASE BID)

SEE SHEET CD412 & C-411

(BID OPTION 3)

SEE SHEET CD413 & C-412

(BID OPTION 3)

SEE SHEET C-404

(BASE BID)

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

SEE SHEET V-401

SEE SHEET V-403 SEE SHEET V-405 SEE SHEET V-407 SEE SHEET V-409

SEE SHEET V-410SEE SHEET V-408

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

0 150 300

1 INCH = 150 FEET

EXISTING CONDITIONS KEY

V-101

SEE SHEET V-406SEE SHEET V-404SEE SHEET V-402

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

TOUL AVE.

CHATEAU THIERRY AVE.

MARNE AVE.

SAINT MIHIEL AVE.

MEUSE AVE.

TO

U

L

AV

E.

C O

N

ST

IT

U

TI

O

N A

VE

SA

N

TI

AG

O D

R

SA

N

TI

AG

O D

R

AP

PO

M O

TT

O

X D

R

AMIENS AVE.

SOISSONS AVE.

ARGONNE AVE.

GETTYSBURG AVE.

GETTYSBURG AVE.

SAN JUAN HILL AVE.

BUENA VISTA AVE.

ANTIETAM AVE.

LO

O

KO

UT

D R.

BE

LL

EA

U

W O

O D

D R

BE

LL

EA

U

W O

O D

D R

SH

IL

O H

D R

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

36" DIA EUC

12" DIA EUC

8" DIA EUC

12" DIA EUC

8" DIA EUC

8" DIA EUC

12" DIA EUC

24" DIA EUC

48" DIA EUC36" DIA EUC

12" DIA EUC

36" DIA EUC

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

ITE

BUILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

6" 6" 13"

9"9"

7" 10"

6"

10" 11"

8"

8"

12"

6"

6"8"

7"

10"

27"

18"

19"

10"

24"

15" 26"

32"

18"

18"

10"

28"

9"

7"

33"

39"

23"

18"

12"

14" 15"

23" 18"

23"

8"

7" 7"

14" 13"

10" 13"

24"

15"

8" 18"

6"

7"

7" 6" 12"

8"

7"

14" 28" 8"

14"

14"

14"

18"

29" 23"

8"

15"

13"

6"

7"

8" 8"

7"36"

48"

7"

6"

8"

36"

8"

16"

6"

16"6"

16"

17"

18"

24"

18"

6"

28"

14"

15" 37"

11"

21"

15"

17" 16" 12"

14" 16"

18"

16"

40"

48"

15"

25"

23"

22"

22"

4"

4"

X

X

X

X

X

X

X

X

X

X

X

24" DIA.

36" DIA.

LARGE MULTI TRUNK

36" DIA.

42" DIA.

24" DIA.

36" DIA.

48" DIA.

MULTI TRUNK

48" DIA.

12" DIA.

36" DIA.

8" DIA.

36" DIA.

STUMP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-401

MATCH LINE - V-402

M

AT

C H

L

IN

E

- V

-4

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

0 40 80

1 INCH = 40 FEET

LO

O

KO

UT

D R

GETTYSBURG AVE

SAN JUAN HILL AVE

BE

LL

EA

U W

O O

D D

R

BU

EN

A

VI

ST

A

AV

E

VETERAN AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

24" DIA PINE

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

17"

6"

40"

21"

27"

55"

30" 20"

27"

15"

12"

15"

9"9"

9"10"

30"

42"

26"

33"

38"

3"

57" 15"

14"

20"

7"

27"

37" 25" 18" 20" 32" 19"

31"

33"

40"

26" 19"

11"13"16"

13"30"10"17"16"10"36"

18"

19"

24"

16"

27"17"

35"

8"

31"16"

18" 12" 9" 11" 16" 8" 7" 8" 12" 12" 6" 12" 12" 11"

14" 27"

29"

24"

25"14"

31"

22"

18"22"17"

19"

12" 10" 8" 8" 10" 13" 9" 10" 13" 23" 12" 6" 8" 8"

8"

12"

30"

16"

34"

41"

X

X

X

X

X

X

X

X

X

X

X

X

X

36" DIA.

36" DIA.

16" DIA.

8" DIA.

8" DIA.

8" DIA.

18" DIA.

8" DIA.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-402

MATCH LINE - V-401

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

S SEPULVEDA BLVD

ARGONNE AVE

SOISSONS AVE

AMIENS AVE

BE

LL

EA

U

W O

O D

D R

BELLEAU W

OOD DR

BUENA VISTA AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

24" DIA EUC36" DIA EUC

24" DIA EUC48" DIA EUC

24" DIA EUC

24" DIA EUC24" DIA EUC

12" DIA EUC

48" DIA EUC

12" DIA EUC

12" DIA EUC

24" DIA EUC

18" DIA EUC

36" DIA EUCALYPTUS

36" DIA EUC

36" DIA EUC

36" DIA EUC

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

24"

16"

10"

13"

8"

27" 15"

25"

27"

19"

9"

13"

18"

13"

30"

15"

21"

19"

15"

16"

14"

10"

9"

10"

23"

15"

9"

18"

19"

23"

24"30"33"31"40"31"

55" 29"39"39"29"37"24"18"33"32"42"27"29"29"25"27"

39"

18"

24"

32"

42" 17" 52" 38"

16"

19"

14"

13"

16"

14"

25"

16"

15"

19"

23"

25"

40"

27"24"

34"

6"

21"

58"

31"

23"

31"

22"

22"

22"

24" DIA EUC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-403

0 30 60

1 INCH = 30 FEET

MATCH LINE - V-404

M

AT

C H

L

IN

E

- V

-4

M

AT

C H

L

IN

E

- V

-4

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

ANTIETAM AVE

VETERAN AVE

GETTYSBURG AVE

SAN JUAN HILL AVE

SH

IL

O H

D R

GETTYSBURG AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

24" DIA HYPSERPA NITIDA

24" DIA HYPSERPA NITIDA

ON-S

IT

E

BU

ILD

IN

G

ON-SITE

BUILDING

12" 8"

50"

13" 12"

36"

34"

20"

10"

14"

14" 6"

29"

7"

5" 18"

9"

10" 6"

20" 24"

18" 12"

7" 25"

24"

19"

12" 14"

24"

18"

36" 40"

15"20"17"

19"

18" 16" 16" 10" 13"

34"

19"14"

20"

15"14"

15" 12"

38"

15" 12" 14" 17"

21"

13"16"10"12"

19"

10"

18" 11" 12"

13"

40"

48" 43"

48"

30"

18"

20"

26"

14" 15"

15" 15"

31"

16" 12"

12"

14" 18"

18"72"

8"

10"10"

10" 8"6"

6"

6"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-404

MATCH LINE - V-403

M

AT

C

H L

IN

E

- V -4

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

S Sepulveda Blvd

AP

PO

M

AT

TO

X

D R

ARGONNE AVE

SOISSONS AVE

AM

IE

N S

AV

E

AMIENS AVE

APPOMATT

OX D

R

BUENA VISTA AVE

SAN JUAN AVE

SH

IL

O H

D R

SAN JUAN AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

OFF

-S

IT

E

BU

ILD

IN

G

50"

6"

6"

4"

8"

12"

12"

8"

8"

8"

12"

6"

15"

11"

20"28"

19"

15"

32"

24"

39"

70"

36"

47"

25"

32"

25"

38" 28" 25" 42" 23" 23" 30" 42"

21" 27" 24" 19" 32" 37" 35" 21" 32"

35" 42"

42" 46"

10"

12"

7"

7"

41"

49"43"34"

13"

11"

9"

11"

19" 15" 16" 17"

24"

14"

11"

9"

39"

17"

12"

17"

16"

16"

11"

34"

16"

13"

14" 19"

11"

12"

13"

22"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-405

MATCH LINE - V-406

M

AT

C H

L

IN

E

- V

-4

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

VETERAN AVE

MEUSE AVE

ST MIHIEL AVE

SA

N

TI

AG

O D

R

MEUSE AVE

C O

N

ST

IT

U

TI

O

N A

VE

C

O N

ST

IT

U

TI

O N

A

VE

SA

N

TI

AG

O D

R

GETTYSBURG AVE

GETTYSBURG AVE

Ap po m at to x

Dr

Antietam Ave

Gettysburg Ave

ANTIETAM AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

ON-S

IT

E

BU

ILD

IN

G

ON-S

IT

E

BU

ILD

IN

G

6"

6"

6"

12"

6"

6"

6"

6"

6"

32"

43" 16"

58"

21"

25"

19"

23"

29"

16"

7"

16"

18"

32"

26"

12"

10"

27"

34"

36"

17"

17"14"14"19"

8"

9"

6"

9"

9"

46" 41"

17" 21"

29"

12"

16"

33"

17"

27"

37"

9"

12"

16"

10"

12"

11"

19"

23"

20"

25"

10"

24"

14" 34"

14"

10"

9"

4"

5"

13"

17"

15"

32"

4" 4"

15"

18"

22"

22"

6"4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-406

MATCH LINE - V-405

M

AT

C

H L

IN

E

- V -4

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

S SEPULVEDA BLVD

Argonne Ave

C on st itu tio n

Av e

TOUL AVE

SA

N

TI

AG

O D

R

SAN JUAN HILL AVE

GETTYSBURG AVE

SAN JUAN HILL AVE

CHATEAU THIERRY AVE

MARNE AVE

GETTYSBURG AVE

GETTYSBURG AVE

APPOMATTOX D

R

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

-S

IT

E

BU

ILD

IN

G OFF

-S

IT

E

BU

ILD

IN

G

42"37"37"31"29"47"32"36"42"41"23"38"39"39"41"40"38"

45"37"31"37"38"31"39"

18" 21" 16" 17" 15" 17" 17" 14" 14" 37" 18"

10" 11"

15"

12"

16"

39"47"29"38"36"38"36"36"

9"

19" 26"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-407

MATCH LINE - V-408

M

AT

C H

L

IN

E

- V

-4

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

VETERAN AVE

MEUSE AVE

ST MIHIEL AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

RENG INE ER

04/21/2023

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

24"

16"12"14"16"18"12"

33"

31"

26"

34" 37"

46" 37" 46"

19" 17" 16" 16" 18"

44" 24" 18" 27" 4" 17" 19" 15" 14" 18" 15" 15" 17" 14" 15"

10"34"42" 36"12"43"44"8"x443"44"35"36"46"

19"

4" 2"

12"

15"

18"

23" 26" 32" 20" 25" 24" 26" 26" 28" 15" 26" 23" 17" 24" 23"

16"

11"20"40"11"41"43"44"13"16"37"

22"22"22"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-408

MATCH LINE - V-407

M

AT

C

H L

IN

E

- V -4

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

MARNE AVE

CHATEAU THIERRY AVE

TOUL AVE

S SEPULVEDA BLVD

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

" D

IA

P

AL

M

" D

IA

P

AL

M

" D

IA

P

AL

M

OFF

-S

IT

E

BU

ILD

IN

G

24"

26"

23"

17"

16"

41"42"43"14"40"34"42"

23"

10"

25"

17"

24"

35"

20"38"40"38"45"36"42"39"39"

15"

21"

14"

19"

26" 27" 15" 21" 29"

40"

51"

26"

51"

24"

12"

23"

20"

18"

23"

23"

18"

23"

25"

15"

4"

28"

28"

33"

32"

32"

28"

28"

25"

24"

25"

22"

23"

23"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-409

MATCH LINE - V-410

M

AT

C H

L

IN

E

- V

-4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCINGVETERAN AVE

W

IL

SH

IR

E

BL

VD

MEUSE AVE

M

EU

SE

A

VE

ST MIHIEL AVE

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

X

X

X

X X

25"

4"

43" 45"

44"

40"49"

18" 15" 18"

17" 23" 14" 16" 19"

24"

16"

27"

24"

20" 18" 18" 21"14" 18" 18" 18" 16" 18"

28"45"43"19"16"42"45"14"44"

24"

18"

20"

18" 19" 18" 28"

20"

26"

17"

18"

21"

16"

16"

18"

8"

6"

6"

8"

4"

8"

6"

8"

25"

25"

27"19"38"47"43"36"43"37"11"

26"

25"

25"

36"

34"

36" 6"

6" 6"6"

6" 6"6"x7

27"

5"

22"

22"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID PACKAGE

N/A

National Cemetery Administration

Design and Construction Service

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

56 Louis Prima Dr, Suite B, Covington, LA 70433

504.684.4408 Jordan Vandermeer

LOS ANGELES NATIONAL CEMETERY

CORRECT FCA DEFICIENCIES

Los Angeles, CA

898CM3036

N/A Project Director

09/08/2023Revisions: Date:

Juan Kays Department of Veterans Affairs, NCA

Phone: 202.632.5057 Email: juan.kays@va.gov Sheet of 77

VCI Project Management Construction Management Engineering

EXISTING CONDITIONS - ENLARGED

V-410

MATCH LINE - V-409

M

AT

C

H L

IN

E

- V -4

0 30 60

1 INCH = 30 FEET

LEGEND AND SYMBOLS

MATCHLINE

EXISTING CONTOUR MAJOR

EXISTING CONTOUR MINOR

EXISTING CURB & GUTTER

EXISTING SIDEWALK

EXISTING TREE

EXISTING MANHOLE

EX. WATER / IRRIGATION BOX

EXISTING ORNAMENTAL FENCING

EXISTING WALLS

EX. SECTION MARKERS / SIGN POST

EXISTING CHAINLINK FENCING

W

IL

SH

IR

E

BL

VDMARNE AVE

TO

U

L

AV

E

TOUL AVE

CHATEAU THIERRY AVE

S SEPULVEDA BLVD

No. 44593

PROFESSIONAL

REGISTERED

JORDAN D. VANDERMEE

File details come from the government source that posted it. Updated .