815CM3041 LINC Bid Set Bk-16.pdf
PDF 10 MB Posted
- Solicitation number
- 36C78624B0005
About this file
This file package relates to a federal construction contract opportunity. The Department of Veterans Affairs National Cemetery Administration is soliciting bids for the Long Island National Cemetery Renovation, Improvements and Repairs Construction Project numbered 815CM3041. The solicitation number is 36C78624B0005. The bid set book contained in the 10MB PDF file provides project details and requirements for renovations, improvements, and repairs at the Long Island National Cemetery. Bids are due under a sealed bid process by the date listed in the solicitation. The awarded firm will be expected to complete the construction work outlined for the cemetery improvements.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4"W 4"W
W
W
W
W
W
W
W
W
FCO
P-11
P-11
FD-A
FD-A
P-30
P-30
P-51
V
2"V
V
V
3"VTR
2"V
GCO
DNDN
IT CLOSET
JANITOR
LOBBY
REST RM 1
CORRIDOR
REST RM 2
STAIR A
STAIR BSTAIR C
DN
FAMILY RM 4
W
W
V
2"V
NEW WORK KEYED NOTES
1 CONNECT NEW 4" SANITARY WASTE PIPE TO EXISTING SANITARY WASTE PIPE
THAT WAS MARKED AND CAPPED DURING DEMOLITION. NOTIFY ENGINEER OF
ANY DISCREPANCIES.
FLOOR DRAIN TO BE TRAP PRIMED. REFER TO SHEET PP-212 FOR DOMESTIC
WATER INTERFACE FOR THE TRAP PRIMER PIPING, SEE DETAIL 9/P002.
GENERAL NOTES
A. VERIFY AND COORDINATE THE INSTALLATION OF THE PLUMBING SYSTEMS WITH
OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS ABOVE CEILING AND
BELOW FLOORS.
B. VERIFY ALL WASTE AND WATER REQUIREMENTS AND LOCATIONS FOR CONNECTING
OWNERS EQUIPMENT PRIOR TO INSTALLATION. PROVIDE ALL NECESSARY MATERIALS
AND COMPONENTS. VERIFY AND INSTALL PER MANUFACTURES WRITTEN
SPECIFICATIONS, INSTRUCTIONS, AND ALL LOCAL AND NATIONAL CODES.
C. COORDINATE WITH ARCHITECTURAL PLANS ALL FIRE OR SMOKE RATED BARRIERS,
WALLS, OR PARTITIONS, AND ALL LOCAL NATIONAL CODES.
D. PLUMBING CONTRACTOR SHALL NOT INSTALL SHUT-OFF VALVES ABOVE WHERE ANY
SHEET ROCK CEILINGS ARE TO BE INSTALLED. WHERE VALVES DO OCCUR, A 2'X2'
ACCESS PANEL SHALL BE INSTALLED. COR SHALL BE NOTIFIED BEFORE PANEL
IS INSTALLED.
E. VERIFY AND COORDINATE ALL PIPING INVERTS WITH EXISTING CONDITIONS
PRIOR TO NEW INSTALLATIONS. PLUMBING DOCUMENTS ARE DIAGRAMMATIC
AND ARE NOT INTENDED TO INCLUDE EVERY ASPECT OF THE REQUIRED WORK.
PLUMBING CONTRACTOR SHALL ENSURE A COMPLETE AND WORKING SYSTEM
IS INSTALLED.
F. FIELD VERIFY EXACT LOCATION AND SIZE OF WASTE, VENT, STORM, AND
WATER PIPING RISERS PRIOR TO ANY DEMOLITION AND RELOCATION. CONTACT
COR ONCE PIPING SYSTEMS HAVE BEEN UNCOVERED/EXPOSED.
G. ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO PROVIDE
COORDINATION DOCUMENTS IN ACCORDANCE WITH THE SPECIFICATIONS.
ADDITIONAL TRANSITIONS REQUIRED DUE TO FIELD CONDITIONS ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
1/2" = 1'-0"
PUBLIC INFORMATION CENTER - GROUND LEVEL - FLOOR PLAN - GRAVITY
LEGEND
N
C
A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg.
Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
KEY
5838 Monroe Road, Suite 100
Charlotte, NC 28212
704 531 3000
Project No. 4624
NOT TO SCALE
3B
2X
2Z2Y
2W 3D
2S
2R
2Q
2D
3F
3C
2U
2T
2M
2K
H
J
C
D
N
O
M L
K
A
B
G
F
2L
2P2N
2M2J
2E2G
2E2G
R
Q
P
Y Z
2A
X
V
T
US
2C
2B
2VW
3A
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
JRC DAS
May 22, 2023
0 1' 2' 4' 8'
PUBLIC INFORMATION CENTER -
PLUMBING - GROUND LEVEL -
FLOOR PLAN - GRAVITY
PP-211
PLUMBING SYMBOLS
GCO
ABBREVIATIONS
PIPE CONTINUES
ELBOW UP
ELBOW DN
GENERAL
PIPING
GRADE CLEANOUT
SANITARY WASTE BELOW FINISHED FLOOR
SANITARY VENT ABOVE FINISHED CEILING
V
W
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text I
P-11
P-11
P-30
P-30
P-50
1/2" CW & HW LINES
FROM BELOW
1/2" CW & HW LINES
FROM BELOW UP
TO ATTIC
1-1/2" CW LINE FROM BELOW
1/2" GAS LINE FROM
BELOW UP TO
ATTIC.
M
B H
M
B H
AHU-PIC-1
100MBH
N
G
P S
I
N
G
P S
I
DNDN
IT CLOSET
JANITOR
LOBBY
REST RM 1
CORRIDOR
REST RM 2
STAIR A
STAIR BSTAIR C
DN
C
W
C
W
H
W
FAMILY RM
1 1/2"CW
3/4"HW 1/2"HW
C
W
C
W
1 1/2"CW1 1/2"CW
H
W
C
W
H
W
EXISTING
GAS WATER
HEATER.
1/2" CW & HW LINES UP
1/2" CW & HW LINES UP 1-1/2" CW LINE UP
C
W
1/2"NG @ 2PSI
100MBH
U P
1/2"CW
BSMT2
NEW WORK KEYED NOTES
1 CONNECT NEW 1-1/2" CW PIPE TO EXISTING 1-1/2" OR LARGER CW PIPE. PC TO
VERIFY EXACT SIZE AND LOCATION PRIOR TO PERFORMING ANY WORK. NOTIFY
ENGINEER OF ANY DISCREPANCIES.
CONNECT NEW 3/4" CW PIPE TO EXISTING HOSE BIBB.
ROUTE 1/2" CW PIPE TO TP-1. ROUTE PIPING FROM TP-1 TO EACH FLOOR DRAIN.
PROVIDE DISTRIBUTION UNIT AND 2 PIPES TO EACH FLOOR DRAIN. SEE SHEET
PP-211 FOR FLOOR DRAIN LOCATIONS, SEE DETAIL 9/P-002
NEW 3/4" CW PIPE DOWN TO AND 3/4" HW PIPE UP FROM EXITING GAS WATER
HEATER - MOUNTED ON FINISHED FLOOR. PROVIDE NEW DRAIN PAN.
CONNECT NEW 1/2" GAS PIPE TO CLOSEST 1/2" OR LARGER GAS PIPE. PC TO
VERIFY EXACT SIZE AND LOCATION PRIOR TO PERFORMING ANY WORK. NOTIFY
ENGINEER OF ANY DISCREPANCIES.
1/2" GAS PIPE TO AHU-OB-1. PROVIDE SHUT OFF VALVE AND VENTLESS
REGULATOR IN ACCESSIBLE LOCATION.
GENERAL NOTES
A. VERIFY AND COORDINATE THE INSTALLATION OF THE PLUMBING SYSTEMS WITH
OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS ABOVE CEILING AND
BELOW FLOORS.
B. VERIFY ALL WASTE AND WATER REQUIREMENTS AND LOCATIONS FOR CONNECTING
OWNERS EQUIPMENT PRIOR TO INSTALLATION. PROVIDE ALL NECESSARY MATERIALS
AND COMPONENTS. VERIFY AND INSTALL PER MANUFACTURES WRITTEN
SPECIFICATIONS, INSTRUCTIONS, AND ALL LOCAL AND NATIONAL CODES.
C. COORDINATE WITH ARCHITECTURAL PLANS ALL FIRE OR SMOKE RATED BARRIERS,
WALLS, OR PARTITIONS, AND ALL LOCAL NATIONAL CODES.
D. PLUMBING CONTRACTOR SHALL NOT INSTALL SHUT-OFF VALVES ABOVE WHERE ANY
SHEET ROCK CEILINGS ARE TO BE INSTALLED. WHERE VALVES DO OCCUR, A 2'X2'
ACCESS PANEL SHALL BE INSTALLED. COR SHALL BE NOTIFIED BEFORE PANEL
IS INSTALLED.
E. VERIFY AND COORDINATE ALL PIPING INVERTS WITH EXISTING CONDITIONS
PRIOR TO NEW INSTALLATIONS. PLUMBING DOCUMENTS ARE DIAGRAMMATIC
AND ARE NOT INTENDED TO INCLUDE EVERY ASPECT OF THE REQUIRED WORK.
PLUMBING CONTRACTOR SHALL ENSURE A COMPLETE AND WORKING SYSTEM
IS INSTALLED.
F. FIELD VERIFY EXACT LOCATION AND SIZE OF WASTE, VENT, STORM, AND
WATER PIPING RISERS PRIOR TO ANY DEMOLITION AND RELOCATION. CONTACT
COR ONCE PIPING SYSTEMS HAVE BEEN UNCOVERED/EXPOSED.
G. ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO PROVIDE
COORDINATION DOCUMENTS IN ACCORDANCE WITH THE SPECIFICATIONS.
ADDITIONAL TRANSITIONS REQUIRED DUE TO FIELD CONDITIONS ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
1/2" = 1'-0"
PUBLIC INFORMATION CENTER - GROUND LEVEL - FLOOR PLAN - PRESSURE
1/2" = 1'-0"
PUBLIC INFORMATION CENTER - BASEMENT LEVEL - FLOOR PLAN - PRESSURE
LEGEND
N
C
A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg.
Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
KEY
5838 Monroe Road, Suite 100
Charlotte, NC 28212
704 531 3000
Project No. 4624
NOT TO SCALE
3B
2X
2Z2Y
2W 3D
2S
2R
2Q
2D
3F
3C
2U
2T
2M
2K
H
J
C
D
N
O
M L
K
A
B
G
F
2L
2P2N
2M2J
2E2G
2E2G
R
Q
P
Y Z
2A
X
V
T
US
2C
2B
2VW
3A
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
JRC DAS
May 22, 2023
0 1' 2' 4' 8'
PUBLIC INFORMATION CENTER -
PLUMBING - GROUND LEVEL -
FLOOR PLAN - PRESSURE
PP-212
PLUMBING SYMBOLS
HW
ABBREVIATIONS
CW
CONNECT TO EXISTING
BALL VALVE
PIPE CONTINUES
ELBOW UP
ELBOW DN
GENERAL
PIPING
HOT WATER
COLD WATER
(E)EXISTING
COLD WATER ABOVE FINISHED CEILING
HOT WATER ABOVE FINISHED CEILING
NATURAL GAS ABOVE CEILING
NG@2PSI
HW
NGNATURAL GAS
MBHTHOUSAND BTUs PER HOUR
CW
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
W
4"W4"W4"W4"W4"W
W
W
3"W
2"W
2"W
2"W
W
W
W
2"W
W
2"W
3"W
W
W
W
4"W4"W
2"W
WCO
WCO
WCO
WCO
WCO
FCO
3"V
V
V
3"V
V
V
3"V
3"V
V
3"V
V
2"V
V
2"V
V
3"V
3"V
2"V
2"V
2"V
2"V
V
V
V
3"VTR
P-31
P-31
P-31
P-31
P-31
P-12P-12
FD-A
FD-A
P-11
P-11
P-11
P-11
P-11
P-11
P-11
P-11
P-50
P-80
V
GCO
P-31
WOMEN
LOBBY
MEN
MECH
MECH
NEW WORK KEYED NOTES
CONNECT NEW 4" SANITARY WASTE PIPE TO EXISTING SANITARY WASTE PIPE
THAT WAS MARKED AND CAPPED DURING DEMOLITION. NOTIFY ENGINEER OF
ANY DESCREPENCIES.
FLOOR DRAIN TO BE TRAP PRIMED, SEE DETAIL 9/P002.
2"W PIPING RAN IN WALL ABOVE GRADE.
GENERAL NOTES
A. VERIFY AND COORDINATE THE INSTALLATION OF THE PLUMBING SYSTEMS WITH
OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS ABOVE CEILING AND
BELOW FLOORS.
B. VERIFY ALL WASTE AND WATER REQUIREMENTS AND LOCATIONS FOR CONNECTING
OWNERS EQUIPMENT PRIOR TO INSTALLATION. PROVIDE ALL NECESSARY MATERIALS
AND COMPONENTS. VERIFY AND INSTALL PER MANUFACTURES WRITTEN
SPECIFICATIONS, INSTRUCTIONS, AND ALL LOCAL AND NATIONAL CODES.
C. COORDINATE WITH ARCHITECTURAL PLANS ALL FIRE OR SMOKE RATED BARRIERS,
WALLS, OR PARTITIONS, AND ALL LOCAL NATIONAL CODES.
D. PLUMBING CONTRACTOR SHALL NOT INSTALL SHUT-OFF VALVES ABOVE WHERE ANY
SHEET ROCK CEILINGS ARE TO BE INSTALLED. WHERE VALVES DO OCCUR, A 2'X2'
ACCESS PANEL SHALL BE INSTALLED. COR SHALL BE NOTIFIED BEFORE PANEL
IS INSTALLED.
E. VERIFY AND COORDINATE ALL PIPING INVERTS WITH EXISTING CONDITIONS
PRIOR TO NEW INSTALLATIONS. PLUMBING DOCUMENTS ARE DIAGRAMMATIC
AND ARE NOT INTENDED TO INCLUDE EVERY ASPECT OF THE REQUIRED WORK.
PLUMBING CONTRACTOR SHALL ENSURE A COMPLETE AND WORKING SYSTEM
IS INSTALLED.
F. FIELD VERIFY EXACT LOCATION AND SIZE OF WASTE, VENT, STORM, AND
WATER PIPING RISERS PRIOR TO ANY DEMOLITION AND RELOCATION. CONTACT
COR ONCE PIPING SYSTEMS HAVE BEEN UNCOVERED/EXPOSED.
G. ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO PROVIDE
COORDINATION DOCUMENTS IN ACCORDANCE WITH THE SPECIFICATIONS.
ADDITIONAL TRANSITIONS REQUIRED DUE TO FIELD CONDITIONS ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
1/2" = 1'-0"
PUBLIC RESTROOMS - GROUND LEVEL - FLOOR PLAN - GRAVITY
LEGEND
N
C
A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg.
Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
KEY
5838 Monroe Road, Suite 100
Charlotte, NC 28212
704 531 3000
Project No. 4624
NOT TO SCALE
3B
2X
2Z2Y
2W 3D
2S
2R
2Q
2D
3F
3C
2U
2T
2M
2K
H
J
C
D
N
O
M L
K
A
B
G
F
2L
2P2N
2M2J
2E2G
2E2G
R
Q
P
Y Z
2A
X
V
T
US
2C
2B
2VW
3A
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
JRC DAS
May 22, 2023
0 1' 2' 4' 8'
PUBLIC RESTROOMS -
PLUMBING - GROUND LEVEL -
FLOOR PLAN - GRAVITY
PP-311
PLUMBING SYMBOLS
GCO
FCO
ABBREVIATIONS
CONNECT TO EXISTING
PIPE CONTINUES
ELBOW UP
ELBOW DN
GENERAL
PIPING
GRADE CLEANOUT
WALL CLEANOUT
FLOOR CLEANOUT
VENT THROUGH ROOF VTR
WCO
SANITARY WASTE BELOW FINISHED FLOOR
SANITARY VENT ABOVE FINISHED CEILING
V
W
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
2"CW
C
W
3/4"HWR
1"HW
1/2"CW
1/2"HW
2"CW2"CW
C
W
1/2"CW
C
W
1 1/2"CW
1 1/2"CW
1 1/2"CW
C
W
C
W
C
W
C
W
3/4"HWR
1/2"HW
1/2"CW
H
W
C
W
1/2"HW
1/2"CW
1/2"HW
1/2"CW
3/4"HW
1/2"HW
1/2"CW
C
W
1/2"CW
H
W
1/2"CW
1/2"HW
C
W
RCP-1
GWH-1
72MBH
1/2"NG @ 2PSI
SA-A
SA-A
SA-A
SA-A
SA-A
SA-A SA-A
P-31
P-31
P-31
P-31
P-31
P-12P-12
P-11
P-11
P-11
P-11
P-11
P-11
P-11
P-11
P-50
P-80
72MBH3/4"HWR
P-31
SA-A
C
W
C
W
WOMEN
LOBBY
MEN
MECH
MECH
NEW WORK KEYED NOTES
1 CONNECT NEW 2" CW PIPE TO EXISTING 2" OR LARGER CW PIPE. PC TO VERIFY
EXACT SIZE AND LOCATION PRIOR TO PERFORMING ANY WORK. NOTIFY
ENGINEER OF ANY DISCREPANCIES.
CONNECT NEW 3/4" CW PIPE TO EXISTING HOSE BIBB.
ROUTE 1/2" CW PIPE TO TP-1. ROUTE PIPING FROM TP-1 TO FLOOR DRAIN. SEE
SANITARY WASTE PLANS FOR FLOOR DRAIN LOCATIONS.
CONNECT NEW 1/2" NATURAL GAS PIPE TO EXISTING 1/2" OR LARGER NATURAL
GAS PIPE. PC TO VERIFY EXACT SIZE AND LOCATION PRIOR TO PERFORMING ANY
WORK. NOTIFY ENGINEER OF ANY DISCREPANCIES.
GENERAL NOTES
A. VERIFY AND COORDINATE THE INSTALLATION OF THE PLUMBING SYSTEMS WITH
OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS ABOVE CEILING AND
BELOW FLOORS.
B. VERIFY ALL WASTE AND WATER REQUIREMENTS AND LOCATIONS FOR CONNECTING
OWNERS EQUIPMENT PRIOR TO INSTALLATION. PROVIDE ALL NECESSARY MATERIALS
AND COMPONENTS. VERIFY AND INSTALL PER MANUFACTURES WRITTEN
SPECIFICATIONS, INSTRUCTIONS, AND ALL LOCAL AND NATIONAL CODES.
C. COORDINATE WITH ARCHITECTURAL PLANS ALL FIRE OR SMOKE RATED BARRIERS,
WALLS, OR PARTITIONS, AND ALL LOCAL NATIONAL CODES.
D. PLUMBING CONTRACTOR SHALL NOT INSTALL SHUT-OFF VALVES ABOVE WHERE ANY
SHEET ROCK CEILINGS ARE TO BE INSTALLED. WHERE VALVES DO OCCUR, A 2'X2'
ACCESS PANEL SHALL BE INSTALLED. COR SHALL BE NOTIFIED BEFORE PANEL
IS INSTALLED.
E. VERIFY AND COORDINATE ALL PIPING INVERTS WITH EXISTING CONDITIONS
PRIOR TO NEW INSTALLATIONS. PLUMBING DOCUMENTS ARE DIAGRAMMATIC
AND ARE NOT INTENDED TO INCLUDE EVERY ASPECT OF THE REQUIRED WORK.
PLUMBING CONTRACTOR SHALL ENSURE A COMPLETE AND WORKING SYSTEM
IS INSTALLED.
F. FIELD VERIFY EXACT LOCATION AND SIZE OF WASTE, VENT, STORM, AND
WATER PIPING RISERS PRIOR TO ANY DEMOLITION AND RELOCATION. CONTACT
COR ONCE PIPING SYSTEMS HAVE BEEN UNCOVERED/EXPOSED.
G. ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO PROVIDE
COORDINATION DOCUMENTS IN ACCORDANCE WITH THE SPECIFICATIONS.
ADDITIONAL TRANSITIONS REQUIRED DUE TO FIELD CONDITIONS ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
1/2" = 1'-0"
PUBLIC RESTROOMS - GROUND LEVEL - FLOOR PLAN - PRESSURE
LEGEND
N
C
A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg.
Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
KEY
5838 Monroe Road, Suite 100
Charlotte, NC 28212
704 531 3000
Project No. 4624
NOT TO SCALE
3B
2X
2Z2Y
2W 3D
2S
2R
2Q
2D
3F
3C
2U
2T
2M
2K
H
J
C
D
N
O
M L
K
A
B
G
F
2L
2P2N
2M2J
2E2G
2E2G
R
Q
P
Y Z
2A
X
V
T
US
2C
2B
2VW
3A
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
JRC DAS
May 22, 2023
0 1' 2' 4' 8'
PUBLIC RESTROOMS -
PLUMBING - GROUND LEVEL -
FLOOR PLAN - PRESSURE
PP-312
PLUMBING SYMBOLS
HWR
HW
ABBREVIATIONS
CW
CONNECT TO EXISTING
BALL VALVE
PIPE CONTINUES
ELBOW UP
ELBOW DN
GENERAL
PIPING
HOT WATER
HOT WATER RETURN
COLD WATER
SHOCK ARRESTOR & PDI SIZE SA-A
COLD WATER ABOVE FINISHED CEILING
HOT WATER ABOVE FINISHED CEILING
HOT WATER RECIRC. ABOVE FINISHED CEILING
NATURAL GAS ABOVE CEILING
NG@2PSI
NG
MBHTHOUSAND BTUs PER HOUR
NATURAL GAS
HWR
HW
CW
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
O
C
GCO
GCO
W
C
W
W
W
W
GCO
GCO
GCO
C
W
C
W
/4
"C W
C
W
"C
W
YH-A 2
YH-A 2
YH-A 2
NEW WORK KEYED NOTES
4" WASTE PIPING UP TO NEW GRADE CLEANOUT FOR WASTE CONNECTION TO
TEMPORARY BATHROOM TRAILER. SANITARY WASTE PIPE SHALL BE SLOPED
MINIMUM 1/8" PER FOOT.
3/4" DOMESTIC COLD WATER PIPING UP TO NEW YARD HYDRANT YH-A.
CONNECT NEW 4" SANITARY WASTE PIPING TO EXISTING SANITARY WASTE PIPING
BELOW GROUND, APPROXIMATELY AS SHOWN. VERIFY EXISTING PIPE IS ACTIVE
AT PROPOSED TIE-IN LOCATION IS ACTIVE AND SUITABLE FOR PROPOSED USE. IF
EXISTING PIPE IS FOUND TO BE INACTIVE OR OTHERWISE UNUSABLE, PROVIDE AN
ALTERNATE CONNECTION POINT TO PROVIDE A FULLY FUNCTIONING AND
CODE-COMPLIANT SYSTEM AT NO ADDITIONAL COST. ALL SANITARY WASTE
PIPING SHALL BE SLOPED A MINIMUM 1/8" PER FOOT.
CONNECT NEW 1" DOMESTIC COLD WATER PIPE TO EXISTING 2" DOMESTIC COLD
WATER PIPE BELOW GROUND. ALL NEW DOMESTIC COLD WATER PIPE
UNDERGROUND SHALL BE ROUTED BELOW FROST LINE A MINIMUM OF 36"
BELOW GROUND TO AVOID FREEZING.
DASHED LINE REPRESENTS APPROXIMATE AREA WHERE PARKING LOT SHALL BE
SAWCUT FOR ROUTE OF NEW SANITARY WASTE AND DOMESTIC COLD WATER
PIPING UNDERGROUND. DEPTH OF TRENCH SHALL ALLOW FOR A MINIMUM OF
1/8" PER FOOT SLOPE AND DOMESTIC COLD WATER PIPING TO BE INSTALLED
BELOW FROST LINE AT A MINIMUM OF 36" BELOW GROUND. EXTENT OF
DEMOLITION SHOWN IS APPROXIMATE.
APPROXIMATE LOCATION OF KNOWN EXISTING BURIED PIPES. SCAN FOR KNOWN
AND UNKNOWN EXISTING BURIED PIPES AND PREPARE FOR FIELD ADJUSTMENTS
AS NECESSARY TO ROUTE ABOVE OR BELOW EXISTING BURIED PIPES AS
APPROVED BY THE COR AT NO ADDITIONAL COST.
GENERAL NOTES
A. VERIFY AND COORDINATE THE INSTALLATION OF THE PLUMBING SYSTEMS WITH
OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS ABOVE CEILING AND
BELOW FLOORS.
B. VERIFY ALL WASTE AND WATER REQUIREMENTS AND LOCATIONS FOR CONNECTING
OWNERS EQUIPMENT PRIOR TO INSTALLATION. PROVIDE ALL NECESSARY MATERIALS
AND COMPONENTS. VERIFY AND INSTALL PER MANUFACTURES WRITTEN
SPECIFICATIONS, INSTRUCTIONS, AND ALL LOCAL AND NATIONAL CODES.
C. COORDINATE WITH ARCHITECTURAL PLANS ALL FIRE OR SMOKE RATED BARRIERS,
WALLS, OR PARTITIONS, AND ALL LOCAL NATIONAL CODES.
D. PLUMBING CONTRACTOR SHALL NOT INSTALL SHUT-OFF VALVES ABOVE WHERE ANY
SHEET ROCK CEILINGS ARE TO BE INSTALLED. WHERE VALVES DO OCCUR, A 2'X2'
ACCESS PANEL SHALL BE INSTALLED. COR SHALL BE NOTIFIED BEFORE PANEL
IS INSTALLED.
E. VERIFY AND COORDINATE ALL PIPING INVERTS WITH EXISTING CONDITIONS
PRIOR TO NEW INSTALLATIONS. PLUMBING DOCUMENTS ARE DIAGRAMMATIC
AND ARE NOT INTENDED TO INCLUDE EVERY ASPECT OF THE REQUIRED WORK.
PLUMBING CONTRACTOR SHALL ENSURE A COMPLETE AND WORKING SYSTEM
IS INSTALLED.
F. FIELD VERIFY EXACT LOCATION AND SIZE OF WASTE, VENT, STORM, AND
WATER PIPING RISERS PRIOR TO ANY DEMOLITION AND RELOCATION. CONTACT
COR ONCE PIPING SYSTEMS HAVE BEEN UNCOVERED/EXPOSED.
G. ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO PROVIDE
COORDINATION DOCUMENTS IN ACCORDANCE WITH THE SPECIFICATIONS.
ADDITIONAL TRANSITIONS REQUIRED DUE TO FIELD CONDITIONS ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
1" = 8'-0"
PUBLIC RESTROOMS - TEMPORARY PLUMBING
LEGEND
N
C
A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg.
Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
KEY
5838 Monroe Road, Suite 100
Charlotte, NC 28212
704 531 3000
Project No. 4624
NOT TO SCALE
3B
2X
2Z2Y
2W 3D
2S
2R
2Q
2D
3F
3C
2U
2T
2M
2K
H
J
C
D
N
O
M L
K
A
B
G
F
2L
2P2N
2M2J
2E2G
2E2G
R
Q
P
Y Z
2A
X
V
T
US
2C
2B
2VW
3A
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
JRC DAS
May 22, 2023
PUBLIC RESTROOMS -
TEMPORARY PLUMBING
PP-313
PLUMBING SYMBOLS
YH-A
GCO
ABBREVIATIONS
CONNECT TO EXISTING
PIPE CONTINUES
ELBOW UP
ELBOW DN
GENERAL
PIPING
YARD HYDRANT
GRADE CLEANOUT
SANITARY WASTE BELOW GROUND
DOMESTIC COLD WATER BELOW GROUND
W
CW
0 4' 8' 16' 24'
AutoCAD SHX Text
RD
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
FIRE ALARM GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
A.
B.
13.
A.
B.
14.
A.
B.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
BEFORE SUBMITTING A PROPOSAL FOR THE WORK, EACH BIDDER WILL BE HELD RESPONSIBLE TO HAVE EXAMINED THE EXISTING SITE CONDITIONS FOR THE WORK INCLUDED UNDER THIS CONTRACT.
NO ALLOWANCE WILL BE MADE SUBSEQUENTLY IN THIS CONNECTION ON BEHALF OF THE
CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART.
NO FIRE ALARM DOCUMENTS/PLANS SHALL BE USED FOR DEMOLITION OF THIS SYSTEM UNLESS
THEY CONTAIN A REVIEW AND APPROVAL STAMP FROM THE AUTHORITIES HAVING JURISDICTION AND A COMPLETED REVIEW BY THE ARCHITECT/ENGINEER. THE AUTHORITIES HAVING JURISDICTION OR ARCHITECT/ENGINEER HAS THE AUTHORITY TO STOP ANY WORK UNTIL SUCH PLANS ARE ON SITE
AND IN USE.
THE NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM.
ALL ALARM DEVICE LOCATIONS SHALL BE COORDINATED WITH LIGHT FIXTURES, HVAC DIFFUSERS, SPRINKLERS, SIGNS, AND OTHER MEP TRADES PRIOR TO CONSTRUCTION.
CONTRACTOR SHALL MAINTAIN A CLEAN WORK PREMISE AT ALL TIMES AND SHALL CLEAN
CONSTRUCTION SITE OF ALL HIS DEBRIS AT THE END OF THE DAY AND BEFORE FINAL PAYMENT IS
MADE.
UNLESS NOTED OTHERWISE ELSEWHERE, FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR
SEALING ALL FIRE RATED WALL PARTITIONS WITH A UL LISTED ASSMEBLY.
WALL PENETRATIONS THROUGH NON-RATED PARTITIONS SHALL BE PROVIDED WITH A NON-
SHRINKING GROUT OR CAULKING MATERIAL AND APPROVED ASSEMBLY.
THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE DESIGN OF THE FIRE
ALARM SYSTEMS AND SHALL PROVIDE SEALED SHOP DRAWINGS. FIRE ALARM DEVICE LAYOUTS,
DEVICES COUNTS, CONDUCTOR TYPES, WIRING DIAGRAMS, I/O MATRIX, RISER DIAGRAMS, AND BATTERY CALCULATIONS SHALL BE SEALED BY AN PROFESSIONAL ENGINEER OR A NICET LEVEL III OR LEVEL IV FIRE ALARM DESIGNER THAT IS REGISTERED IN THE STATE WHERE THE WORK IS TO
OCCUR.
FLOOR/WALL PENETRATIONS THROUGH RATED SEPARATIONS SHALL BE SEALED WITH AN APPROVED
FIRE RATED MATERIAL.
THE FIRE ALARM PLANS ARE FOR COORDINATION AND BIDDING PURPOSES ONLY. THE FIRE ALARM
CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE DESIGN.
THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF WALLS
AND CEILING REQUIRED FOR THE INSTALLATION OF THE NEW FIRE SUPPRESSION SYSTEM.
UNLESS NOTED OTHERWISE ELSEWHERE, FIRE ALARM SHOP DRAWINGS SHALL INCLUDE
REFLECTIVE CEILING PLANS THAT INDICATE THE FOLLOWING:
CEILING TYPES AND GRID
ALL CEILING MOUNTED DEVICES (LIGHTS, DIFFUSERS, SPRINKLERS, AND ALL SPECIAL
ELECTRICAL SYSTEMS).
THE FIRE ALARM CONTRACTOR SHALL LOCATE CEILING MOUNTED DEVICES AS FOLLOWS:
ALL DEVICES SHALL BE LOCATED IN THE CENTER OF ONE QUADRANT (2' x 4').
IN GYP. BOARD CEILINGS FIRE ALARM DEVICES SHALL BE LOCATED IN SYMMETRICAL PATTERNS
RELATIVE TO OTHER DEVICES LOCATED IN THE CEILING.
THE CIRCUIT WIRING SHALL BE SIZED AS FOLLOWS
NOTIFICATION APPLIANCE CIRCUITS SHALL BE A MINIMUM OF #14 AWG.
SIGNAL LINE CIRCUITS SHALL BE A MINIMUM OF #18 AWG AND MAXIMUM OF #14 AWG.
ALL SMOKE DUCT DETECTORS CONCEALED ABOVE CEILINGS SHALL BE PROVIDED WITH A REMOTE
LED INDICATING TEST STATION AT THE NEAREST CORRIDOR.
THE FIRE ALARM SYSTEM SHALL BE AN ADDRESSABLE SYSTEM INCLUDING INDIVIDUALLY
ADDRESSED DEVICES.
ALL FIRE ALARM HORN-STROBES SHALL BE TAPPED AT 1/2 WATT UNLESS NOTED OTHERWISE.
ALL FIRE ALARM DEVICES ARE TO BE WHITE WITH CONTRASTING LETTERING.
CONDUCTORS FOR DETECTORS, MANUAL STATIONS AND SUPERVISORY DEVICES CAN BE INSTALLED IN THE SAME CONDUIT BUT MUST BE INSTALLED IN A SEPARATE CONDUIT FROM ALL INDICATING
DEVICES (HORN/STROBE,STROBE) AND FROM 120 VAC CIRCUITS.
USE THE EXISTING LOCAL FIRE ALARM CONTROL PANEL AND ADD ZONE CARD AND POWER SUPPLY
AS NECESSARY.
FURNISH AND INSTALL END-OF-LINE RESISTORS AND CLEARLY MARK THE LOCATION OF THIS DEVICE.
CONNECT DUCT SMOKE DETECTORS IN THE HVAC SYSTEM (FURNISHED BY THE MECHANICAL
CONTRACTOR AND INSTALLED BY THE MECHANICAL CONTRACTOR) TO ACTIVATE THE FIRE ALARM
SYSTEM AND SHUTDOWN THE HVAC SYSTEM IN THE EVENT OF SMOKE DETECTED IN THE HVAC
DUCTS.
ALL FIRE ALARM SYSTEM COMPONENTS SHALL BE UL LISTED.
FURNISH AND INSTALL DUCT SMOKE DETECTOR TEST STATION IN CEILING TO SHOW LOCATION OF
DETECTOR WHEN IN ALARM OR TROUBLE.
WHERE APPLICABLE, ELECTRICAL AND FIRE ALARM CONTRACTORS ARE TO PROVIDE CONNECTIONS
TO EACH FIRE DAMPER AND SMOKE DAMPER TO PERMIT OPERATION OF THE DAMPERS IN ALARM
AND TEST MODES. FIRE DAMPERS REQUIRE POWER FOR ELECTRICAL RESET. REFER TO FIRE/SMOKE
DAMPER DETAIL AND REFER TO ELECTRICAL CONTRACT DRAWINGS FOR PANEL SCHEDULES AND
CIRCUIT NUMBER.
IN THE EVENT OF A CODE CONFLICT, THE MOST RESTRICTIVE CODE OR STANDARD SHALL BE
OBSERVED AND COMPLIED FOR THIS PROJECT.
FOLLOWING THE FIRE ALARM SYSTEM INSTALLATION, A 100% FIRE ALARM SYSTEM ACCEPTANCE
TEST SHALL BE CONDUCTED BY THE FIRE ALARM CONTRACTOR FOR THE SCOPE OF WORK SHOWN
ON THESE DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT, ENGINEER, OWNER AND
ALL AUTHORITIES HAVING JURISDICTION WITHIN FIVE (5) WORKING DAYS OF THE TEST FOR
SCHEDULING.
ALL FIRE ALARM NOTIFICATION APPLIANCE SIGNALS SHALL SOUND A TEMPORAL THREE PATTERN
UNLESS OTHERWISE SPECIFIED BY THE AUTHORITY HAVING JURISDICTION.
ALL VISUAL APPLIANCE CANDELA RATING SHALL CONFORM TO NFPA, ADA AND ALL AUTHORITIES
HAVING JURISDICTION REQUIREMENTS.
ALL NOTIFICATION DEVICES SHALL BE SYNCHRONIZED AND INSTALLED AS DEFINED BY NFPA 72 AND
INTERNATIONAL BUILDING CODE REQUIREMENTS.
ALL FIRE ALARM DEVICES AND NOTIFICATION APPLIANCES SHALL BE ACCESSIBLE FOR PERIODIC
INSPECTIONS, MAINTENANCE AND TESTING PURPOSES.
ALL FIRE ALARM DEVICES AND NOTIFICATION APPLIANCES SUBJECT TO MECHANICAL DAMAGE SHALL
BE PROTECTED BY A MANUFACTURER'S APPROVED PROTECTIVE COVER/GUARD.
THE FIRE ALARM CONTRACTOR SHALL NOT PROTECTIVE COVERS FROM DETECTORS UNTIL AFTER
THE CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL.
THE FIRE ALARM CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS DURING THE INSTALLATION
OF THE FIRE ALARM SYSTEM.
A FIRE ALARM SYSTEM RECORD OF COMPLETION SHALL BE PRESENTED TO THE ARCHITECT,
ENGINEER, AND OWNER'S REPRESENTATIVE AT THE CONCLUSION OF THIS FIRE ALARM SYSTEM
INSTALLATION.
A VOLTAGE DROP CALCULATION SHALL BE PERFORMED AND SUBMITTED BY THE FIRE ALARM
CONTRACTOR FOR POWER CONSUMING CIRCUITS; IN ORDER TO VALIDATE THAT THE SYSTEM HAS BEEN DESIGNED WITHIN NFPA TOLERABLE LIMITS. NOTIFICATION APPLIANCE DEVICES CIRCUIT
VOLTAGE DROP CALCULATIONS SHALL HAVE A MAXIMUM VOLTAGE DROP OF 15% AND A
PREFERRED VOLTAGE DROP OF 10% MEETING NFPA 72, SECTION 10.3.5.
THE FIRE ALARM SYSTEM SHALL BE AN ADDRESSABLE SYSTEM INCLDING INDIVIDUALLY ADDRESSED
DEVICES.
THE CONTRACTOR SHALL PROVIDE THE OWNER WITH OPERATING, TESTING, MAITENANCE
INSTRUCTION, SITE SPECIFIC SOFTWARE CHANGES/ADDITIONS, AND AS-BUILT DRAWINGS AT THE CONCLUSION OF THIS FIRE ALARM INSTALLATION. IT IS THE OWNER'S RESPONSIBLITY TO MAINTAIN ALL RECORDS OF THIS FIRE ALARM INSTALLATION IN A LOCATION APPROVED BY THE AUTHORITY
HAVING JURISDICTION.
THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A ZONE MAP IN ACCORDANCE WITH NFPA
STANDARDS AT THE CONCLUSION OF THIS FIRE ALARM INSTALLATION. IT IS THE OWNER'S
RESPONSIBILITY TO MAINTAIN ZONE MAPS IN CURRENT CONDITIONS THROUGHOUT THE LIFE OF THIS
FIRE ALARM SYSTEM.
THE CONTRACTOR SHALL PROVIDE THE OWNER WITH MAINTENANCE AND TESTING SCHEDULE FOR
ALL EQUIPMENT FURNISH/INSTALLED UNDER THIS SCOPE OF WORK IN ACCORDANCE QITH NFPA 72
GUIDELINES.
ALL FIRE ALARM CABLE SHALL BE INSTALLED PER NFPA 70 REQUIREMENT.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
A.
B.
a.
b.
57.
58.
59.
60.
61.
62.
A.
B.
63.
64.
65.
66.
67.
ALL FIRE ALARM CABLE SHALL BE MONITORED FOR INTEGRITY IN ACCORDANCE WITH NFPA 70 AND NFPA 72
REQUIREMENTS.
ALL FIRE ALARM CIRCUITS SHALL BE DURABLY MARKED AND LABELED WHERE THE IDENTIFICATION SHALL BE
CLEARLY VISIBLE.
ALL FIRE ALARM CABLE SHALL BE INSTALLED IN A NEAT, WORKMAN LIKE MANNER.
ALL FIRE ALARM CABLES SHALL BE INSTALLED IN A CONDUIT OR METALLIC RACEWAY AND BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. FIRE ALARM CABLE SHALL NOT BE STRAPPED, TAPED OR ATTACHED BY ANY MEANS TO THE EXTERIOR OF ANY CONDUIT OR OTHER RACEWAY AS A MEANS OF SUPPORT.
ALL FIRE ALARM CABLE SHALL BE SUPPORTED BY STRAPS, HANGERS OR SIMILAR FITTING DESIGNED AND
INSTALLED SO AS NOT TO DAMAGE THE CABLE.
ALL FIRE ALARM CABLES SHALL BE ACCESSIBLE; WHERE, BUILDING FEATURES DO NOT PROVIDE ACCESSIBILITY, OR THE FIRE ALARM CABLE SHALL BE INSTALLED IN AN APPROVED METAL RACEWAY.
ALL WIRING SHALL BE SECURED TO THE STRUCTURE AS SPECIFIED IN NFPA 70.
ALL CONDUIT/RACEWAY SHALL BE SECURED TO THE STRUCTURE AS SPECIFIED IN NFPA 70.
THE FIRE ALARM SYSTEM ADDITION AND/OR MODIFICATIONS SHALL BE TEST FREE OF GROUNDS.
THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DETERMINING CABLE FILL/CONDUIT SIZING PER NFPA 70
REQUIREMENTS (ALL FIRE ALARM CONDUIT SHALL BE A MINIMUM SIZE OF 3/4 - INCH).
ALL FIRE ALARM CABLE, CONDUIT AND METALLIC RACEWAYS SHALL BE RED.
THE EXISTING ADDRESSABLE FIRE ALARM SYSTEM SHALL BE EXPANDED AS NEEDED TO SERVE THE RENOVATED AREA. NEW ADDRESSABLE DEVICES AND CONDUCTORS SHALL BE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM. PROVIDE NEW BATTERIES AND POWER SUPPLIES, AS REQUIRED. PROVIDE PROGRAMMING OF EXISTING FIRE ALARM SYSTEM IN ORDER TO ADD NEW POINTS AS REQUIRED DUCTS THE RENOVATION SHOWN ON THESE
CONTRACT DOCUMENTS.
WHERE, VISUAL, AUDIBLE AND NOTIFICATION DEVICES ARE ADDED TO THE EXISTING SYSTEM THE FIRE ALARM CONTRACTOR SHALL BE REQUIRED TO INCLUDE POWER AVAILABILITY ANALYSIS SHOWING THAT THE INTENDED SOURCE OF POWER, THE NOTIFICATION CIRCUIT CAPACITY AND STABILITY POWER AVAILABILITY; IN ORDER TO VALIDATE THAT THE EXISTING BATTERY SECONDARY POWER SOURCE SHALL HAVE A MINIMUM OF 20 PERCENT SAFETY MARGIN ABOVE THE CALCULATED AMP-HOUR CAPACITY REQUIRED. ANY CASES WHERE THE 20 PERCENT SAFETY MARGIN ABOVE THE CALCULATED AMP-HOUR CAPACITY IS NOT BEING MET THE SECONDARY SOURCE BATTERIES SHALL BE REPLACED AND UPGRADED AT THE BUILDING'S MAIN FIRE ALARM CONTROL PANEL TO MEET
NFPA 72 REQUIREMENTS BY THIS FIRE ALARM CONTRACTOR/INSTALLER.
DUCT DETECTORS SHALL BE MONITORED FOR INTEGRITY AND PROVIDE A SUPERVISOR SIGNAL AT THE SUPERVISORY FIRE ALARM CONTROL PANEL (FACP). AIR HANDLER SYSTEMS SHALL BE RAN AND BLOWN OUT
PRIOR TO THE INSTALLATION OF SMOKE DETECTORS.
MAINTAINABILITY
EXTERNAL AND INTERNAL PARTS SHALL BE ARRANGED SO THAT WHEN INSTALLED, ALL PARTS REQUIRING MANIPULATION, OBSERVATION, AND/OR MAINTENANCE ARE READILY ACCESSIBLE AND SAFE FOR OPERATION AND MAINTENANCE PERSONNEL. WHEREVER PRACTICAL, INSTRUMENTS AND EQUIPMENT SHALL BE LOCATED
SUCH THAT THEY CAN BE OPERATED AND EASILY ACCESSED FROM GRADE LEVEL.
MAINTAINABILITY SHALL BE INCORPORATED INTO THE DESIGN OF ALL CONTRACTOR SUPPLIED EQUIPMENT.
THE PRIMARY MAINTAINABILITY OBJECT SHALL BE TO MINIMIZE THE COMPLEXITY AND TIME REQUIRED FOR MAINTENANCE. THE FOLLOWING GENERAL CRITERIA SHALL BE FOLLOWED TO ACHIEVE THIS OBJECTIVE:
CONTRACTOR SUPPLIED EQUIPMENT SHALL BE LOW MAINTENANCE DESIGN AND SHALL BE EASILY
MAINTAINABLE.
CONTRACTOR SUPPLIED EQUIPMENT SHALL BE DESIGNED TO BE MAINTAINED IN PLACE, IF POSSIBLE, WITH MINIMUM DISASSEMBLY OF SURROUNDING EQUIPMENT AND MINIMUM USAGE OF TEMPORARY
SCAFFOLDING AND HANDLING EQUIPMENT.
DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EACH AND EVERY CONDUCTOR, FITTING DEVICE, RACEWAY OR COMPLETE DETAIL OF ALL THE WORK TO BE PERFORMED, BUT ARE FOR THE PURPOSES OF ILLUSTRATING THE TYPE OF SYSTEM AND CONDITIONS NECESSARY FOR AN EXPERIENCED TRADESMAN TO LAY OUT HIS WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING SUCH SITE EVALUATIONS AND
MEASUREMENTS AS NECESSARY TO PROPERLY COMPLETE THE WORK.
UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL PRESENT THE ENGINEER, ARCHITECT AND OWNER WITH A REPORT CONFIRMING TESTING OF ALL NEW DEVICES IN THE PROJECT ZONE; ALONG WITH APPROPRIATE SELECTED TESTING OF THE MAIN FIRE ALARM SYSTEM TO CONFIRM CONTINUED PROPER OPERATION. A CERTIFICATE OF APPROVAL FROM THE APPROPRIATE AGENCY INSPECTION AGENT WILL BE REQUIRED PRIOR TO
FINAL ACCEPTANCE OF THE PROJECT.
ALL CONCEALED CONDUCTORS SHALL BE INSTALLED IN EMT RACEWAYS, JUNCTION AND OUTLET BOXES SHALL BE STEEL; EXPOSED BOXES SHALL HAVE SOLID SIDES WITH ONLY ONE ENTRANCE KNOCKOUT. A FIRE ALARM SYSTEM RECORD OF COMPLETION SHALL BE PRESENTED TO THE ARCHITECT, ENGINEER, AND OWNER'S
REPRESENTATIVE AT THE CONCLUSION OF THIS FIRE ALARM SYSTEM INSTALLATION.
DUCT DETECTORS SHALL BE MONITORED FOR INTEGRITY AND PROVIDE A SUPERVISOR SIGNAL AT THE SUPERVISORY FIRE ALARM CONTROL PANEL (FACP). AIR HANDLER SYSTEMS SHALL BE OPERATED AND PURGED
PRIOR TO THE INSTALLATION OF SMOKE DETECTORS.
WHERE A DUCT SMOKE DETECTOR IS LOCATED ABOVE A CEILING OR IN A DIFFICULT TO REACH LOCATION, PROVIDE A REMOTE INDICATING LAMP AND A TEST KEY SWITCH ON NEARBY WALL AT 7 FEET AFF TO FACILITATE
TESTING.
UNLESS OTHERWISE NOTED THE FOLLOWING MINIMUM SURVIVABILITY CRITERIA SHALL BE MET:
SIGNALING LINE CIRCUIT (SLC) CLASS “ B ”.
NOTIFICATION ALARM CIRCUIT (NAC) CLASS “ B ”.
SPRINKLER SYSTEM MONITORING: FIRE ALARM CONTRACTOR SHALL MAINTAIN SUPERVISION OF ANY EXISTING SPRINKLER SYSTEM BEING MODIFIED AS PART OF THIS PROJECT AT ALL TIMES. CONTRACTOR SHALL
COORDINATE TRANSFER WITH OWNER AND ENGINEER OF RECORD.
THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE ARCHITECT/ENGINEER
WITHOUT ADDITIONAL COMPENSATION TO THE CONTRACTOR.
THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR PROVIDING DESIGN SHOP DRAWINGS, CALCULATIONS, ETC., INCLUDING BUT NOT LIMITED TO ALL ITEMS WHICH APPLY AS OUTLINED IN NFPA 72 SECTIONS 7.2, 7.4 AND 7.5, TITLED, "MINIMUM REQUIRED DOCUMENTATION", "SHOP DRAWINGS (INSTALLATION DOCUMENTATION)," AND
"COMPLETION DOCUMENTATION".
FIRE/SMOKE AND DUCT SMOKE DETECTORS SHALL BE PLACED ON THE NORMAL POWER PANEL CIRCUIT. REFER
TO ELECTRICAL DISCIPLINE DRAWINGS FOR WIRING CONFIGURATION.
THIS CONTRACTOR IS RESPONSIBLE FOR SUBMISSION OF SYSTEM RECORD OF COMPLETION MEETING NFPA 72, FIGURES 7.8.2(a) FOR REVIEW AND COMMENT BY THE VA AND ENGINEER OF RECORD. ALL SYSTEM RECORD OF COMPLETIONS MUST BE DATED, PRINTED NAME OF INDIVIDUALS WHO SIGNED THE SYSTEM RECORD OF COMPLETION AND SIGNATURES. ALL TEST MUST BE COORDINATED WITH THE VA COR, VA FIRE SAFETY OFFICIAL AND THE ENGINEER OF RECORD. SIGNATURES BY NON VA FIRE OFFICIALS WILL NOT BE ACCEPTED.
DESIGN CODES, STANDARDS & PARTIES OF REFERENCE
SCOPE OF WORK
NOT IN CONTRACT
AREA OF WORK
CEILING MOUNTED SMOKE DETECTOR, PHOTOELECTRIC TYPE ONLY
WALL MOUNTED FIRE ALARM STROBE. CD = CANDELA RATING/SETTING.
CEILING MOUNTED REMOTE INDICATOR.
F
ADA
AHJ
AIM
AOM
A
AUTO
A/CO
AFF
AFG
AWG
BATT
BSMT
BR
BOB
BMS
CD
CLG
CM
C
DN
DACT
EA
ELEC
EL
EOL
EXIST
XP
EX
FM
FA
FAA
FL
GALV
GPM
GA
GC
GR
GND
GFI
HP
HVAC
FIRE ALARM ABBREVIATIONS
AMERICANS WITH DISABILITIES ACT
AUTHORITY HAVING JURISDICTION
ADDRESSABLE INPUT MODULE
ADDRESSABLE OUTPUT MODULE
AMPERE
AUTOMATIC
ABOVE CONCRETE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMERICAN WIRE GAUGE
BATTERY
BASEMENT
BREAKER
BOTTOM OF BEAM
BUILDING MANAGEMENT SYSTEM
CANDELA
CEILING
CEILING MOUNTED
CONDUIT
DOWN
DIGITAL ALARM COMMUNICATOR
TRANSMITTER
EACH
ELECTRIC/ELECTRICAL
ELEVATION
END ON LINE RESISTOR
EXISTING
EXPLOSION PROOF
EXTERIOR
FACTORY MUTUAL GLOBAL
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FLOOR
GALVANIZED
GALLONS PER MINUTE
GENERAL ALARM (BUILDING WIDE)
GENERAL CONTRACTOR
GRADE
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
HORSEPOWER
HEATING VENTING AND AIR CONDITIONING
INPUT / OUTPUT
INTERIOR
ISOLATOR MODULE
JUNCTION BOX
LIGHTING
LIQUID CRYSTAL DISPLAY
LOCAL OPERATING CONSOLE
MAIN CIRCUIT BREAKER
MAIN FIRE ALARM PANEL
MASS NOTIFICATION SYSTEM
NATIONAL FIRE PROTECTION ASSOCIATION
NATIONAL ELECTRIC CODE
NORMALLY CLOSED
NORMALLY OPENED
NOT IN CONTRACT
NOTIFICATION APPLIANCE CIRCUIT
NOT APPLICABLE
NOT TO SCALE
PANEL
PHASE
PROTECTOWIRE
PRESSURE SWITCH
SIGNALING LINE CIRCUIT
SOLENOID
SPECIFICATION
STEEL
TAMPER SWITCH
TOP OF CONCRETE
TOP OF STEEL
TYPICAL
UNDERWRITERS LABORATORY
UNLESS NOTED OTHERWISE
UNITED STATES DEPARTMENT OF VETERANS AFFAIRS
VALVE
VOLT
VOLTS DIRECT CURRENT
WATERFLOW SWITCH
WATT
WALL MOUNTED
WEATHERPROOF
WIREGUARD
I/O
INT
ISO
JB
LTG
LCD
LOC
MCB
MFAP
MNS
NFPA
NEC
NC
NO
NIC
NAC
NA
NTS
PNL
PH
PW
PS
SLC
SOL
SPEC
STL
TS
TOC
TOS
TYP
UL
UNO
VA
VAL
V
VDC
FS
W
WM
WP
WG
FIRE ALARM AND DETECTION NOTE
FIRE ALARM AND DETECTION PLANS ARE SHOWN FOR BIDDING
PURPOSES. FIRE ALARM AND DETECTION CONTRACTOR IS TO
SUBMIT SHOP DRAWING. FIRE ALARM CALCULATIONS MEETING
NFPA 72 AND VA FIRE PROTECTION DESIGN MANUAL, ALL SHOP
DRAWINGS AND CALCULATION ARE TO BE SIGNED, STAMPED AND
SEALED BY EITHER A LICENSED FIRE PROTECTION ENGINEER IN
THE STATE WHERE WORK WILL BE PERFORMED OR A NICET
LEVEL III OR IV CERTIFICATION IN FIRE ALARM SYSTEM LAYOUT.
ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE VA
REQUIREMENTS AND APPLICABLE CODES.
( NOTE: SYMBOLS WITHIN THIS SCHEDULE ARE REPRESENTATIVE
OF THOSE TYPICALLY FOUND ON THE DRAWINGS. ALL SYMBOLS
MAY NOT APPEAR ON THIS SET OF DRAWINGS. )FIRE ALARM SYMBOLS
WALL MOUNTED FIRE ALARM AUDIBLE-VISUAL NOTIFICATION DEVICE. CD = CANDELA RATING/SETTING.
WALL MOUNTED AUDIBLE ONLY FIRE ALARM DEVICE.
CD
CEILING MOUNTED FIRE ALARM AUDIBLE-VISUAL NOTIFICATION DEVICE. CD = CANDELA RATING/SETTING.
CD
C WALL MOUNTED FIRE ALARM CHIME DEVICE.
CO
RI
CEILING MOUNTED CARBON MONOXIDE (CO) DETECTOR.
CEILING MOUNTED FIXED TEMPERATURE HEAT DETECTOR. 135°F UNLESS OTHERWISE NOTED.
CD
CEILING MOUNTED FIRE ALARM STROBE. CD = CANDELA RATING/SETTING.CD
WALL MOUNTED FIRE ALARM MANUAL PULL STATION. 48"AFF TO TOP OF BOX, UNLESS OTHERWISE NOTED.
CO
CEILING MOUNTED COMBINATION SMOKE / HEAT / CO DETECTOR. COMBINATION MAY VARY, SEE PLANS.
FACP WALL MOUNTED ADDRESSABLE FIRE ALARM CONTROL PANEL.
FAA WALL MOUNTED FIRE ALARM REMOTE ANNUNCIATOR PANEL.
CEILING MOUNTED RATE-OF-RISE HEAT DETECTOR.
R
F
THE FOLLOWING PUBLICATIONS AND AUTHORITIES HAVING JURISDICTION SHALL BE
REFERENCED FOR THE DESIGN OF THE FIRE PROTECTION SYSTEM ON THIS PROJECT:
1. ANSI, A117.1 STANDARD, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES.
2017 EDITION
2. ASCE 7 - MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 2022
EDITION
3. NFPA 70 - NATIONAL ELECTRIC CODE, 2023 EDITION
4. NFPA 72 - NATIONAL FIRE ALARM & SIGNALING CODE, 2022 EDITION
5. NFPA 101 - LIFE SAFETY CODE. 2021 EDITION LIFE SAFETY CODE, 2021 EDITION
6. NFPA 170 - LIFE SAFETY CODE, 2021 EDITION
7. NFPA 241 - STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERNATION AND
DEMOLITION OPERATIONS, 2022 EDITION
8. VA FIRE PROTECTION DESIGN MANUAL, JUNE 1, 2021 EDITION
9. VA SEISMIC DESIGN REQUIREMENTS, REVISED MAY 1, 2020 EDITION
10. VA FIRE SAFETY
SYMBOLS, NOTES,
ABBREVIATIONS, AND
DRAWING INDEX
FA-001
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000 Project No. 4624
JRC NGE
May 22, 2023
296289
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
CONSULTANTS
NTS
TO
NEXT
DEVICE
FROM
FCP
OR
PREVIOUS
DEVICE
DATA
OUT(+)
DATA
OUT(-)
DAT
A
IN(+)
DAT
A
IN(-)
34 2 1
ALARM/
ACTIVE
NORMAL
RED
LED
GRN
LED
SIGA-CT1
78TB2
TB1
TYP.N.O.
INITIATING
DEVICE
EOL
47K
OHM
NTS
TO
NEXT
DEVICE
FROM
FCP
OR
PREVIOUS
DEVICE
DATA
OUT(-)
DATA
OUT(+)
DAT
A
IN(-)DAT
A
IN(+)
NTS
MOUNTING
BASE
ASSY.
ADAPTER
STRAP
(PART OF BASE ASSY.)
4"X 4"X 2-1/8"
JUNCTION
BOX
ALARM
HORN
JUNCTION
BOX
MOUNTING
PLATE
XENON
STROBE
ALARM LAMP
SINGLE INPUT MODULE 7
INTELLIGENT PHOTOELECTRIC SMOKE
DETECTOR 10TYPICAL SMOKE DETECTOR MOUNTING DETAIL 9
FIRE ALARM HORN/STROBE LIGHT 6NTS
NTS
6" MIN
80" MIN &
96" MAX
FINISHED FLOOR
CEILING
MANUAL FIRE
ALARM
STATION
5'-0" MAX
TYPICAL EXIT DOORWAY
48" MAX
42" MAX
4" MIN
12" MAX
20" MAX
WALL MOUNTED
HEAT
DETECTOR
WALL MOUNTED
SMOKE DETECTOR
3MOUNTING HEIGHTS OF DEVICES
GENERAL DETAIL NOTES:
A. PARTICULAR ATTENTION SHALL BE GIVEN TO THE ALIGNMENT OF
DEVICES. WHEREVER DEVICES, ON THIS SHEET OR OTHER SHEETS,
ARE SHOWN AT GIVEN LOCATION WITH DIFFERENT MOUNTING HEIGHTS
THEY SHALL BE ALIGNED VERTICALLY (TO THE CENTER LINE). IF THEY
ARE SHOWN AT THE SAME MOUNTING HEIGHT THEY SHALL BE ALIGNED
HORIZONTALLY (TO THE TOP OF COVER PLATE). REFER TO THE
ARCHITECTURAL PLANS, ELEVATIONS AND DETAILS. COORDINATE
WITH ARCHITECT PRIOR TO ROUGH-IN.
B. ALL DIMENSIONS ARE TO THE CENTER LINE OF DEVICE UNLESS
INDICATED OTHERWISE.
C. MOUNTING HEIGHTS SHOWN HERE ARE TYPICAL. PRIOR TO ROUGH-IN,
COORDINATE WITH ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS.
IF A CONFLICT OCCURS, REQUEST CLARIFICATION FROM ARCHITECT/
ENGINEER PRIOR TO ROUGH-IN.
PIPE SLEEVE THROUGH FLOOR DETAIL 5NTS
PIPEPIPE
INSULATION
(WHERE
REQ'D)WATERPROOF
CAULK
(WATER PROOF
FLOORS
ONLY
METAL
DECK
6"
PIPE
SLEEVE
CONTINUOUSLY WELDED WATER
STOP & ANCHOR COLLAR,
WATERPROOF FLOORS
MIN. 1" ALL OTHERS TO HAVE
ANCHOR LUGS (MIN. 3 REQ'D).
FIRE
RESISTANT
SILICONE FOAM
SEALER
CONCRETE FLOOR SLAB
STANDARD C-CLAMP PIPE HANGER 1
PIPE SLEEVE THROUGH WALL DETAIL 8
NTS
DESIGN DATA FOR C-CLAMP HANGER
A
C R
1-1/8"
1. C-Clamp
2. Set Screw
3. Lock Nut
4. Hanger Rod
5. Adjustable Hanger Ring
6. Steel Beam or Bar Joist
Components:
1/2-69 1/48
1/2-4 1/27 3/46
1/2-3 3/46 3/45
3/8-364
3/8-2 1/25 1/23
3/8-2 1/452 1/2
3/8-1 3/44 1/42
3/8-1 1/241 1/2
3/8-1 1/23 3/41 1/4
3/8-1 1/43 1/21
3/8-1 1/43 1/23/4
3/8-1 1/43 1/21/2
Diameter
Rod
Takeout
Hanger
A Dimension
Minimum
Size
Pipe
Nominal inchesinchesinches
NTS
PIPE
NOTES:
1. FOR INTERIOR WALLS
AND BELOW GRADE
GROUND TO GROUND
WALLS
CUT OPENING IN
EXISTING MASONRY
WALL LARGER THAN
SLEEVE AND FORM &
FILL WITH
EXPANSIVE
TYPE GROUT
FIRE
RESISTANT
SILICONE FOAM
SEALER
ESCUTCHEON PLATE
ON ONE OR BOTH
SIDES WHERE PIPING
IS EXPOSED
PIPE SLEEVE
EXISTING POURED
CONCRETE OR
C.M.U. WALL.
ANCHOR
LUGS
(MIN. 3 REQ'D)
PIPE
INSULATION
(WHERE REQ'D)
A
A
Section A-A
1. RATED WALL OR FLOOR ASSEMBLY - PROVIDE FIRE STOPPING ASSEMBLY FOR
PARTITION TYPE & RATING ENCOUNTERED.
2. THROUGH PENETRATION - PROVIDE FIRE STOPPING ASSEMBLY FOR SIZE &
MATERIAL OF THROUGH PENETRATION UTILIZED.
3. FIRE STOPPING MATERIAL - PROVIDE FIRE STOPPING MATERIAL FOR WALL
ASSEMBLY & THROUGH PENETRATION MATERIAL ENCOUNTERED. FILL VOIDS OR
CAVITY ACCORDING TO THE REQUIREMENTS OF THE FIRE STOPPING SYSTEM
UTILIZED.
ALL RATED WALLS, PARTITIONS OR FLOORS SHALL BE PROVIDED WITH A UL LISTED
FIRE STOP SYSTEM. THE SYSTEM UTILIZED SHALL MATCH THE SEPARATION
PENETRATED AND THE THROUGH PENETRATION MATERIAL.
DETAILS FOR THE INSTALLATION OF SYSTEM TYPE UTILIZED SHALL BE AVAILABLE AT
THE PROJECT SITE FOR THE DURATION OF CONSTRUCTION AND SHALL BE PROVIDED
TO THE AUTHORITY HAVING JURISDICTION AND TO THE BUILDING OWNER AT THE
PROJECT COMPLETION.
PROVIDE WALL OR FLOOR LABELS INDICATING THE SYSTEM MANUFACTURER AND UL
LISTED ASSEMBLY NUMBER AT EACH LOCATION WHERE THE FIRE STOPPING SYSTEM
IS INSTALLED.
THROUGH PENETRATION FIRESTOP SYS.
(PROVIDE UL LISTED SYSTEM)
NTS
FIRE ALARM RISER DIAGRAM AND INPUT/OUTPUT MATRIX 4
NOTES:
1. DEVICES SHOWN ARE TYPICAL. REFER TO FIRE ALARM SHEETS FOR DEVICE
LOCATIONS AND QUANTITIES.
2. PROVIDE END OF LINE RESISTORS AS REQUIRED.
3. ANNUNCIATION SHALL BE THREE TEMPORAL BEEPS.
4. DUCT SMOKE DETECTORS AND DAMPERS SHALL BE PROVIDED AND WIRED TO
FATC AND POWER BY ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR
SHALL INSTALL DUCT SMOKE DETECTORS AND DAMPERS.
5. FOR LARGER DUCTS, PROVIDE ADDITIONAL DUCT DETECTORS AS REQUIRED BY NFPA 72.
6. EQUIPMENT MUST BE COMPATIBLE WITH THE FIRE ALARM CONTROL PANEL SOFTWARE.
NTS
MANUAL PULL FIRE ALARM
AU
D
IB
LE
A
LA
R M
S
AC
TI
VA
TI
O
N
AREA SMOKE DETECTOR
HEAT DETECTOR
A
AC
TU
AT
E
ST
R
O
BE
S
INPUTS
OUTPUTS
TR
AN
SM
IT
A
LA
R M
T O
R
EM
O
TE
S
TA
TI
O
N
D
IS
PL
AY
A
LA
R M
S
IG
N
AL
D
IS
PL
AY
S U
PE
R
VI
SO
R Y
SI
G
N
AL
D
IS
PL
AY
T R
O U
BL
E
SI
G
N
AL
TR
AN
SM
IT
S U
PE
R
VI
SO
R Y
SI
G
N
AL
TR
AN
SM
IT
T R
O U
BL
E
SI
G
N
AL
R
EC
O R
D E
VE
N
T
AT
F
AC
P
FIRE SPRINKLER SYSTEM TAMPER
FIRE ALARM AC POWER FAILURE
FIRE ALARM LOW BATTERY
FIRE ALARM OPEN CIRCUIT
FIRE ALARM GROUND FAULT
NOTIFICATION APPLIANCE CIRCUIT FAULT
FIRE ALARM PANEL CLEAR
B C D E F G H I J K L M N O P
A B C D E F G H I J K L M N O P
FIRE ALARM SEQUENCE OF OPERATION
7. EXTEND EXISTING ADDRESSABLE FIRE ALARM SYSTEM INTO RENOVATED AREA,
PROVIDE LATEST DESIGN AND MODEL DEVICES COMPATIBLE WITH
MANUFACTURER, MAKE AND MODEL OF EXISTING FIRE ALARM SYSTEM.
PROVIDED ALL REQUIRED CONDUIT, CONDUCTORS, TERMINATORS, SOFTWARE,
RE-PROGRAMMING, TESTING, ADDITIONAL POWER SUPPLIES, EXTENDERS,
MODULES, ETC., AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM.
EXISTING DACT COMMUNICATOR TO REMAIN CONNECTED TO UL APPROVED
MONITORING SERVICE.
SO
U
N D
G
EN
ER
AL
B U
IL
D
IN
G
A
LA
R M
THE FIRE ALARM NOTIFICATION SYSTEM SHALL GO INTO ALARM UPON ACTIVATION OF A MANUAL PULL OR AREA SMOKE DETECTOR. THE ALARM SHALL BE DISPLAYED BY AUDIBLE AND VISUAL NOTIFICATION APPLIANCES. THE FIRE ALARM SYSTEM SHALL DISPLAY A TROUBLE CONDITION UNDER LOSS OF POWER, OR IF A SMOKE DETECTOR IS REMOVED FROM THE BASE. THE FIRE ALARM SYSTEM SHALL DISPLAY A
SUPERVISORY CONDITION UPON ACTIVATION OF CARBON MONOXIDE DETECTOR.
CARBON MONOXIDE DETECTOR
RI
FSDDDTSFS
CONDUCTORS PER MANUFACTURER'S
PUBLISHED RECOMMENDATIONS
IN 3/4"C MINIMUM (TYPICAL)
NEW
P
C C
P
NEW
ADDRESSABLE
FACP
O
PE
N L
O C
KE
D
E G
R
ES
S D
O O
R S
O N
FL
O
O R
O F
FI
R
E O
R
IG
IN
DETAILS AND MATRIX
FA-002
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2021, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
FACILITY RENOVATION
LONG ISLAND NATIONAL CEMETERY
815CM3041
Final Construction Documents - Issued for Construction
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000 Project No. 4624
JRC NGE
May 22, 2023
296290
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
UP
UP
BSMT
BSMT
BSMT 004
BOILER
BSMT
BSMT
BSMT
ST2
STAIR 2
ST1
STAIR 1
ST3
STAIR 3
UP
UP
UP
GAS
BOILER
GAS
WATER
HEATER
FA
C
P
F
CO
R1
F
F
F
UP
DN
DN
LIVING RM
SUNROOM
FOYER 1
DINING
POWDER
KITCHEN
BATH 1
PASSAGE ST2
STAIR 2
BEDRM 1
FOYER 2
CLOSET
STR3
STAIR 3
177cd
15cd
15cd
30cd
CO
CO
15cd
15cd
FAA F
F
F
GENERAL NOTES
A. REFER TO DRAWING FA-001 FOR FIRE ALARM GENERAL NOTES, ABBREVIATIONS
AND SYMBOLS.
B. REFER TO FA-002 FOR FIRE ALARM INPUT / OUTPUT MATRIX. ALL FIRE ALARM
DEVICES SHALL BE INTERFACED WITH THE EXISTING FIRE ALARM SYSTEM AND
PROGRAMMING OF THE NEW POINTS AT THE LOCAL AND MAIN FIRE ALARM
CONTROL PANELS.
C. THE DRAWING SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE
SCALE WHEN INDICATED FOR GENERAL REFERENCE ONLY.
D. THE INFORMATION GIVEN HEREIN IS AS EXACT AS COULD BE SECURED FOR
BIDDING PURPOSES AND ITS ACCURACY IS NOT GUARANTEED. THE FIRE ALARM
CONTRACTOR IS RESPONSIBLE FOR EXAMINING NEW JOB CONDITIONS AND
VERIFYING ALL MEASUREMENTS, DISTANCES, ELEVATIONS, CLEARANCES, PIPE
SIZES, ETC., BEFORE STARTING THE DEMOLITION OR NEW WORK.
E. MANUAL FIRE ALARM PULL STATIONS SHALL BE LOCATED WITHIN 60 INCHES OF
EACH EXIT DOORWAY.
F. THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING
EXISTING CONDITIONS PRIOR TO CONSTRUCTION. THE EXISTING FIRE ALARM
EQUIPMENT ABOVE CEILING AND WITHIN WALLS WILL NEED TO BE FIELD VERIFIED.
G. THE CONTRACTOR SHALL ADHERE TO THE SEPARATION DISTANCES BETWEEN
SPEAKER STROBES SHOWN ON THESE CONTRACT DRAWINGS; SINCE, PER THE VA
FIRE PROTECTION DESIGN MANUAL SECTION 7.3.F(2) (k) THE VA FPDM CLEARLY
STATES THAT " SPEAKERS MUST BE INSTALLED AND ARRANGED SO THEY ARE
CLEARLY HEARD AND UNDERSTOOD BY STAFF UNDER NORMAL WORKING
CONDITIONS. A RULE OF THUMB FOR SPEAKER LAYOUT IS TO INSTALL THEM
EVERY TWENTY-FIVE TO THIRTY FEET ON CENTER AND NOT TO EXPECT THEM TO
CLEARLY HEARD…