36C78620B0006-010.pdf
PDF Posted
- Solicitation number
- 36C78620B0006
About this file
This pre-solicitation notice is for an invitation for bid for a gravesite expansion project at Fort Smith National Cemetery. The Department of Veterans Affairs National Cemetery Administration intends to issue the solicitation on or about May 11, 2020 for the Fort Smith National Cemetery Gravesite Expansion Project 847CM3019. The acquisition will be set aside 100% for service-disabled veteran owned small businesses. To be eligible, offerors must be verified in the Vendor Information Pages database and registered in SAM.gov. The NAICS code is 237990 for other heavy and civil engineering construction with a size standard of $36.5 million. The construction magnitude is between $2 million and $5 million. Questions should be directed to the contracting officer via email. Offers must come from verified SDVOSBs and be submitted electronically through beta.SAM.gov. Amendments will be posted to the website rather than mailed.
36C78620B0006 S02_Attachment-7_PLANS_847CM3019_Part5.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78620B0006 0001.docx | DOCX document | |
| S06_Amendment 0001_Attachment 2_02 41 10 DEMO SITE CLEARING.pdf | ||
| 36C78620B0006-006.pdf | ||
| 36C78620B0006-011.pdf | ||
| 36C78620B0006-005.pdf | ||
| 36C78620B0006-012.pdf | ||
| 36C78620B0006-008.pdf | ||
| 36C78620B0006-007.pdf | ||
| 36C78620B0006-003.docx | DOCX document | |
| 36C78620B0006-014.xlsx | XLSX spreadsheet | |
| 36C78620B0006-004.pdf | ||
| 36C78620B0006-013.pdf | ||
| 36C78620B0006-009.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
National Cemetery
Administration
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT MANAGER STAMPCONSULTANT
321 4 5 6 7 8 9 10
BURIAL EXPANSION
FORT SMITH, ARKANSAS
847CM3019
N/A Project Director
Revisions: Date:
BID DOCUMENTS
APRIL 3, 2020
LI502
ALM CDW
N.T.S.
AIR RELEASE VALVE ASSEMBLY
N.T.S.
TRASH RECEPTACLE
N.T.S.
FLOWER VASE HOLDER WITH HINGED LID
TRASH
28"
19"
FLOWERS VASES
19"
28"
28"
HINGED LID - SEE PLAN VIEW
5/8" O.D. STEEL ROD
3/8" X 1" STEEL BARS
1/4" X 2
" SOLID STEEL BAR
DECAL - VS WHITE LETTERING, CLEAR
BACKGROUND
1/4" X 2
" SOLID STEEL BAR BOLT TO
SLAB
FINISH GRADE
NOTE:
FLORAL REGULATIONS SHALL BE PLACED ON LID OF RECEPTACLE
REFER TO U.S. DEPARTMENT OF VETERANS AFFAIRS, NATIONAL
CEMETERY SIGNS (NC-08.01) PAGE 12-4-34
VICTOR STANLEY
S-424 IRONSIDES TRASH
RECEPTACLE COLOR: BLACK
VICTOR STANLEY
S-42 IRONSIDES
TRASH RECEPTACLE
COLOR: BLACK
BLACK LETTERS, WHITE
BACKGROUND
FLORAL REGULATIONS
TEXT AS APPROVED BY CEMETERY
DIRECTOR
HANDLE
HINGED LID
N.T.S.
IRRIGATION HEAD PLACEMENT
HEADSTONE (TYP.)
SPUN STEEL LID
5/8" O.D. STEEL ROD
3/8" X 1" STEEL BARS
1/4" X 2
" SOLID STEEL BAR
DECAL - VS WHITE LETTERING,
CLEAR BACKGROUND
1/4" X 2
" SOLID STEEL
BAR BOLT TO SLAB
FINISH GRADE
IRRIGATION HEAD
(SEE PLAN FOR TYPE)
E
Q
U
A
L
D
I
S
T
A
N
C
E
E
Q
U
S
T
A
N
C
E
E
Q
U
S
T
A
N
C
E
E
Q
U
S
T
A
N
C
E
HEADSTONE (TYP.)
N.T.S.
FLOWER WATERING STATION
FINISH GRADE
APPLIED ENGINEERING 1730-18 BLACK
VALVE BOX WITH BLACK BOLT DOWN
COVER AND EXTENSIONS AS REQUIRED
AIR RELEASE VALVE (SEE LEGEND)
SCH 80 PVC NIPPLE (LENGTH AS REQUIRED)
NIBCO T-113 BRONZE GATE VALVE WITH
HANDWHEEL
IRRIGATION MAINLINE TEE
IRRIGATION MAINLINE
8"X8"X16" SOILD CMU BLOCK
1" DIAMETER WASHED ROCK
HOT BRAND LID WITH 3" TALL BY 3/16"
DEEP LETTERS: "ARV"
FILTER FABRIC
INSTALL AN 8"X8"X16" SOLID CMU BLOCK AT EACH CORNER OF VALVE BOX.
WASHED ROCK SHALL BE INSTALLED FLUSH WITH BOTTOM OF GATE VALVE.
4" MIN CLEARANCE BETWEEN VALVE BOX LID AND HIGHEST OBJECT IN BOX.
N.T.S.
BENCH DETAIL
VICTOR STANLEY BENCH
STEELSITES RB-28, 6 FT.
COLOR: BLACK
6" THICK 4000 PSI CONCRETE
SLAB W/MEDIUM BROOM FINISH
-SLOPE AT 2% TO DRAIN
1/2" PRE-MOLDED JOINT FILLER
AND SEALER ALONG ENTIRE
LENGHT OF SLAB
MOUNTABLE CURB AND GUTTER
- SEE CIVIL PLANS
95% COMPACTED SUBGRADE
FINISH GRADE
(SEED BED)
(1) 5/8" I.D. ANCHOR
BOLT (TYP. OF 4) - CUT
BOLT ABOVE NUT AND
PEEN
NOTE:
1. FOR BENCHES LOCATED AT BACK OF CURB, BENCH SHALL BE ORIENTED
TO FACE GRAVE SITES.
GRAVE SITES
GRAVE SITES
BENCH SHALL BE ORIENTED TO FACE GRAVE SITES
BENCH
CURB AND GUTTER
7' -
FLORAL REGULATIONS:
"Fresh cut flowers may be placed on graves at any time. Temporary flower vases are available in bins along cemetery streets. Floral items will be removed from graves and disposed of by cemetery personal as soon as they become withered, faded, or unsightly. During the mowing season flowers will be removed prior to the next mowing. Cemetery supplied vases shall not be removed from cemetery grounds.
Artificial flowers may be placed on graves only during the period of November 1 through March 1.
Potted plants will be permitted on graves only during the period 10 days before and 10 days after Easter Sunday and
Memorial Day, and Veterans Day.
Christmas wreaths or grave blankets are permitted on graves commencing December 1 and will be removed not later than January 21 of each year. Grave floral blankets may not be larger in size than two by three feet.
Floral items and other types of decorations shall not be secured to the headstones or markers.
Permanent plantings, statues, vigil lights, similar commemorative items, and breakable of hazardous objects of any kind are not permitted on graves at any time. These objects will be removed and disposed of by cemetery personnel whenever found.
Permanent flowers are only authorized in the old burial sections. Please contact Cemetery Director for information regarding installation of a permanent flower containers in these sections."
53 4
IRRIGATION DETAILS
EXTRA HEAVY
BRASS RISER
BRASS STRAP (TYP.
OF 2) - SCREW TO
POST WITH BRASS
SCREWS
3/8 " REVEAL, TYP.
THREE SIDES
POST - SEE PLAN
VIEW
SELF CLOSING
FAUCET HAWS
MODEL #6252 EHLF
BRASS FINISH - NO
CHROME
FLOWER WATER SPIGOT MAIN LINE (SEE
IRRIGATION PLANS FOR WATER SPECIFICATION
AND ROUTING)
7 -
NOTE:
CONCRETE POST COLOR SHALL BE LIGHT GRAY
- SUBMIT COLOR SAMPLE TO LANDSCAPE
ARCHITECT FOR APPROVAL PRIOR TO CASTING
POSTS.
POST PLAN VIEW
N.T.S.
WATER SPIGOT
ASSEMBLY
1" CHAMFERED
EDGE AT TOP OF
POST
3 - #3 REBAR
EQUALLY SPACED
STAINLESS STEEL
ANCHOR 1/4" X 2"
(DRIVE PIN)
ALUMINUM PLATE PAINTED
BLUE TO MATCH VICTOR
STANLEY BLUE WITH WHITE
LETTERS READING "DO NOT
DRINK"
ARCHITECTURAL PRECAST
3000 PSI CONCRETE POST -
LIGHT SANDBLAST FINISH
REVEAL
3/8"
7 -
4"
1/8"
5/8" 1"
1/8" 3- 3/4"
1/8"
1/8" 5/8" 1"
Drink
Do Not
ARCHITECTURAL
PRECAST POST
AND COLLAR
ARCHITECTURAL PRECAST POST AND
COLLAR
R
ARCHITECTURAL PRECAST POST AND COLLAR ENLARGED VIEW
ARCHITECTURAL
PRECAST POST
AND COLLAR
GRADE
SECTION A-A
PLAN
S E
C T
I O
N
A
4.3.20
(3) Willow Oak
10.41"
(28) Low Scape
Hedger Chokeberry
(28) Low Scape
Hedger Chokeberry
(8) Willow Oak
(5) Willow Oak
(184) Switch Grass
TREES QTY BOTANICAL / COMMON NAME CONT CAL
16 Quercus phellos / Willow Oak B & B 4"Cal
SHRUBS QTY BOTANICAL / COMMON NAME CONT. HEIGHT
52 Aronia melanocarpa `UCONNAM166` TM / Low Scape Hedger Chokeberry5 gal
184 Panicum virgatum `Hot Rod` / Switch Grass 1 gal
GROUND COVERS QTY BOTANICAL / COMMON NAME TYPE
160,926 sf Cynodon dactylon / Tif Tuf Bermuda Grass sod
PLANT SCHEDULE
COMPACTED OR
UNDISTURBED SOIL
METAL FENCE POSTS IN
UNDISTURBED SOIL OUTSIDE OF
TREE PIT
PLANTING SOIL
MIXTURE
FINISH GRADE
1" X 18" WOVEN NYLON TREE
STRAP WITH GROMMENTS
ON EACH END.
TWO STRANDS OF #12
GAUGE GALVANIZED WIRE
3" SAUCER
PEEL BURLAP FROM TOP OF
TREE BALL
ROOT BALL
NOTE: PRUNE ALL BROKEN &
DAMAGED BRANCHES, AFTER
PLANTING
5' DIAMETER MULCH RING, 3"
DEEP (SEE SPECS)
9" MIN
N.T.S.
DECIDUOUS TREE
PLANTING DETAIL
ROOT FLARE SHALL BE VISIBLE AND TREE
PLANTED WITH ROOT FLARE A MIN. OF 2"
ABOVE FINISHED GRADE ADJACENT TO
PLANTING PIT
ADD
D
2" DEPTH MULCH (SEE
SPECS.)
PREPARE GROUNDCOVER PLANTING BED
SOIL BY THOROUGHLY ROTO-TILLING
PLANTING SOIL AMENDMENT(S) (SEE SPECS.)
INTO PROPER TOPSOIL TO THE DEPTH
SHOWN
UNDISTURBED SOIL
6" 0.C.
9" 0.C.
12" O.C.
18" O.C.
24" O.C.
30" O.C.
36" O.C.
5.2"
7.8"
10.4"
15.6"
20.8"
26.0"
31.2"
SPACING "D" ROW "A"
PLANT SPACING
M
I N
SEE PLANT LIST
FOR SPACING
PERENNIALS AND
GRASSES PLANTING DETAIL
N.T.S.
N
1"=40.0'
0' 40' 80'20'
PLANTING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
National Cemetery
Administration
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT MANAGER STAMPCONSULTANT
321 4 5 6 7 8 9 10
BURIAL EXPANSION
FORT SMITH, ARKANSAS
847CM3019
N/A Project Director
Revisions: Date:
BID DOCUMENTS
APRIL 3, 2020
1"=10.0'
0' 10' 20'5'
ENLARGEMENT
PLANTING PLAN
LP101
ALM CDW
1. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND
UTILITY LINES PRIOR TO EXCAVATING.
2. ALL WATER REQUIRED FOR LANDSCAPE OPERATIONS WILL BE PROVIDED
BY OWNER FROM ON-SITE SOURCES AT NO CHARGE TO CONTRACTOR.
3. NO SUBSTITUTIONS SHALL BE ALLOWED WITHOUT APPROVAL BY THE NCA
OR THEIR TECHNICAL REPRESENTATIVE.
4. QUANTITIES IN THE PLANT LIST ARE FOR INFORMATION ONLY.
CONTRACTOR SHALL VERIFY ON PLAN.
5. ALL DISTURBED AREAS SHALL RECEIVE SOD OR SEED.
6. ANY PLANTING BED ADJACENT TO WALKS OR CURBING SHALL HAVE THE
GRADE LOWERED TO A SUFFICIENT DEPTH TO ALLOW THE TOP OF THE
MULCH TO MATCH THE TOP OF WALK OR CURBING.
7. ALL SEEDED AREAS ON 4:1 OR GREATER SLOPES SHALL HAVE EROSION
CONTROL BLANKET (FUTERRA F4 NETLESS, OR APPROVED EQUAL)
SECURED WITH SOD STAPLES PER THE MANUFACTURE'S
RECOMMENDATION FOR SPACING.
8. MULCH SHALL BE GRADE A SHREDDED CYPRESS MULCH INSTALLED IN A 3"
LAYER AROUND ALL TREES.
9. PLANTS SHALL BE TAGGED WITH LABELS IDENTIFYING COMMON AND
BOTANICAL NAME UNTIL FINAL ACCEPTANCE IS GIVEN.
10. ALL EXISTING TREES TO REMAIN SHALL BE PROTECTED DURING
CONSTRUCTION (SEE CIVIL DRAWING FOR TREE PROTECTION MEANS AND
METHODS).
LANDSCAPE NOTES
NOTE:
REMOVE ALL GRAVEL AND
CONSTRUCTION DEBRIS FROM
CONSTRUCTION STAGING / ACCESS
AREA AND ALL HAUL ROAD, TILL
COMPACTED SUBSOIL, BRING GRADE
TO MATCH SURROUNDING AREA AND
SOD.
(184) Switch Grass
LP101
4.3.20
GENERAL
1. Refer to Architectural, Mechanical, Electrical, and Plumbing series drawings for floor elevations, slopes, drains, and location of depressed and elevated floor areas.
2. Structural series drawings shall be compared with drawings of other series; differences shall be referred to the Architect for instruction.
3. The general contractor is responsible for coordination of all resulting revisions to the structural system or other trades as a result of acceptance of contractor proposed alternatives or substitutions.
4. The general contractor and sub-contractors shall determine the scope of the structural work from the contract documents taken as a whole. The structural drawings shall not be considered separately for purposes of bidding the structural work. Due consideration shall be given to other structural work or work related to the structure, including necessary coordination described or implied by the Architectural, Civil and MEP drawings.
5. Safety Measures: At all times the Contractor shall be solely and completely responsible for the conditions of the job site, including, but not limited to:
A. Safety of the persons and property, B. Means and methods of construction, C. Compliance with applicable OSHA requirements and guidelines, D. All necessary independent engineering reviews of these conditions.
6. The contractor shall brace and/or shore the construction as required to provide a safe and true structure. Where bracing and/or shoring is indicated in the drawings, it is done so only as a courtesy to the contractor and shall not relieve the contractor of their responsibility to coordinate the work with the aforementioned provisions. The Architect's or Engineer's job site review is not intended to include review of the adequacy of the contractor's safety measures.
7. Principal openings in the structure are indicated on the contract documents. Refer to the architectural and MEP drawings for openings, sleeves, curbs, inserts, etc. not indicated on the structural drawings. Submit new or modified opening locations to StructuresPE, LLP for review and approval.
8. The reproductive use of the structural contract documents or electronic files as structural shop drawing documents by the contractor or sub-contractors is not allowed. Submitting copies of the structural drawings is unacceptable and will be rejected.
9. Scales noted on the drawings are for general reference only. No dimensional information shall be obtained by direct scaling of the drawing.
10. These drawings do not, nor are intended to, locate property lines, building set backs nor height limitations. It is the contractor's responsibility to locate the building and construct it to, and within, applicable code restrictions. Further, it is the Civil Engineer's responsibility to address site drainage appropriate to the site and in consideration of adjoining properties.
CODES
1. The structure and components shown in these drawings have been designed under the guidelines of the structural requirements listed in the 2018 International Building Code with required amendments.
2. Minimum Design Loads & Associated Criteria for Buildings & Other Structures, ASCE/SEI 7-16
3. Structural Concrete: American Concrete Institute, ACI 318-14
4. Structural Masonry: 2016 Building Code for Masonry Structures, ACI530-16/ASCE5-16/TMS 402-16
DESIGN BASIS
1. Foundations:
The following allowable soil capacities are per the Geotechnical Report noted in the Foundation and Site Preparation section of the structural notes:
Grade Beams and Slab:
Allowable Bearing Pressure:
Total Load: 2,000 psf
* Minimum required penetration into specific bearing stratum. Testing laboratory shall confirm the proper bearing strata per Geotechnical report.
** Neglect upper x feet of stratum for skin friction capacities.
2. Earthquake Loads (does not control design): The structure has been designed in accordance with ASCE 7 including the following seismic design parameters:
Risk Category II Seismic Importance Factor IE =1.0 Mapped Spectral Acceleration, Short Period SS = 0.157 Mapped Spectral Acceleration, 1-Second Period S1 = 0.086 Site Class D Spectral Response Coefficient, Short Period SDS = 0.168 Spectral Response Coefficient, 1-Second Period SD1 = 0.137 Seismic Design Category C Basic Seismic Force Resisting System Ordinary Reinforcement Masonry
Shear Walls Design Base Shear(s) V = CS Wx (per ASCE7 Section 11.7) Seismic Response Coefficient CS = 0.01 Response Modification Factor R = 2 Analysis Procedure Used ELFP
3. Ground Snow Load: PG = 5 psf.
FOUNDATION AND SITE PREPARATION
1. Geotechnical information indicated in the structural drawings are intended to replicate the recommendations stated in the geotechnical report. The geotechnical report shall govern in the case of any discrepancies. Contractor shall comply with recommendations indicated therein and all clarifications and interpretations of the report shall be made by the Geotechnical Engineer.
2. The subsurface information and foundation design are based on a geotechnical report prepared by Terrcon, Project Number 04195121, dated January 24, 2020. The contractor shall perform excavations, foundation construction, and preparation of the subgrade under the slab on grade in accordance with the recommendations contained in the geotechnical report and Contract Documents. See DESIGN BASIS notes for design values from the report.
3. Within the foundation outline, remove all fat clay and/or unstable, completely weathered limestone strata, all organics (I.E., roots, trees, grass, and other humus), any building foundations or rubble, and any other deleterious materials to a minimum depth of 24".
4. Foundation conditions noted during construction, which differ from those described in the geotechnical report shall be reported to the architect, geotechnical engineer and StructuresPE, LLP before further construction is attempted.
5. Slab on grade may, at the contractor's option, be underlain by a maximum of 2 inches of sand.
6. The floor subgrade shall be properly compacted and proof-rolled and shall be free of standing water, mud and frozen soil.
7. In areas where limestone is exposed at the cut surface, remove a depth of limestone to provide for at least 6" of compacted select fill. In areas where soil or completely weathered limestone is exposed, scarify at least six inches of the cut soil subgrade and recompact to at least 95% of the maximum dry density determined using Amerian Standard Testing Method (ASTM) D 1557 conducted with a laboratory compacted effort of 7.30 FT lbs/cu. in. Hold water contents within ± 2%.
8. Contractor shall bring the building pads to grade with select fill material conforming to the recommendations of the geotechnical report. Contractor shall certify the compaction of the select fill material according to the testing requirements of the geotechnical report.
9. Means and methods of utility attachment shall be the responsibility of the contractor and do not fall under the scope of these structural documents.
10. The foundation design assumptions do allow for a limited amount of potential vertical rise that will not affect structural stability. This allowance in design does not cover architectural, mechanical, electrical or plumbing features.
11. Do not allow water or debris to stand in trenches. It bottoms of trenches become softened due to rain or slurry or other water before concrete is placed, excavate softened material and replace with properly compacted backfill or concrete.
CONCRETE
1. Concrete in the following areas shall have the following characteristics:
28-day Max w/ Max Usage Strength (f'c) Slump (in.) A cm Ratio Air content B,C Agg. Size
Grade Beams: 4000 psi 3-5 0.50 3-6% 1" Spread Footings: 4000 psi 3-5 0.50 -- 1"
A. Slump shall be measured before adding water reducing admixture or plasticizing mixture.
B. Do not allow air content to exceed 3 percent for trowel-finished floors or for concrete slabs receiving a polished finish.
C. Specified air content is only required when elements are permanently exposed to weather and outside of the conditioned building envelope perimeter.
2. The minimum amounts of cementitious material may be changed if a concrete performance mix is submitted to the structural engineer for approval two weeks prior to placing any concrete. The performance mix shall include the amounts of cement, fine and course aggregate, water and admixtures, as well as the water-cement ratio, slump, and strength data in accordance with ACI 318.
The use of a performance mix requires batch plant inspection, the cost of which shall be paid by the general contractor. Review of mix submittals by the Engineer of Record indicates only that information presented conforms generally with contract documents. Contractor or supplier maintains full responsibility for specified performance.
3. All concrete mix designs shall be reviewed and approved by the testing agency prior to sending to the engineer of record for approval.
4. Use the following cementitious materials, of the same type, brand and source throughout the Project:
Portland Cement: ASTM C 150, Type I/II
5. Fly ash may be used as a pozzolan to replace a portion of the portland cement in a concrete mix, subject to the approval of the structural engineer. Fly ash, when used, shall conform to ASTM C618, Type C or F. Concrete mixes using fly ash shall be proportioned to account for the properties of the specific fly ash used and to account for the specific properties of the fly ash concrete thus resulting.
The ratio of the amount of the fly ash to the total amount of fly ash and cement in the mix shall not exceed the following:
Architecturally Exposed Concrete Slabs: 10 percent All Other Concrete: 25 percent
6. Normal weight aggregates shall conform to ASTM C33 and be provided from a single source. Fine aggregates shall be free of materials with deleterious reactivity to alkali in cement
7. Water shall conform to ASTM C 94/C 94M and be potable.
8. Admixtures if used shall be subject to the approval of the structural engineer.
9. Water shall not be added to the concrete at the jobsite unless the total water quantity including the water added at the jobsite does not exceed the total water quantity of the reviewed mix design. It shall be the responsibility of the contractor to coordinate the requirements of the concrete supplier and pumper to meet this requirement and to ensure a pumpable and workable mix. The use of plasticizers, retardants, and other additives shall be at the option of the contractor subject to the approval of StructuresPE, LLP. Follow the recommendations of the manufacturer for the proper use of additives. the use of calcium chloride or other chloride bearing salts is not permitted.
10. Mixing, transporting, and placing of concrete shall conform to ACI 301 and ASTM C 94.
11. Conformance to ACI 305.1 "Specification for Hot Weather Concreting" is required when air temperature is above 90 deg F.
12. Conformance to ACI 306 "Cold Weather Concreting" is required when a period for more than three
(3) consecutive days, the average daily air temperature is below 40 deg F and the air temperature is not greater than 50 deg F for more than one-half of any 24 hour period.
13. General contractor shall notify the architect and StructuresPE, LLP 48 hours prior to placement of concrete in the foundation.
14. Detailing of concrete reinforcement bars and accessories shall conform to the recommendations of ACI 315 "Details and Detailing of Concrete Reinforcement" and ACI SP-66 "Detailing Manual".
Placing of reinforcing bars shall conform to the recommendations of ACI 315R "Manual of Engineering" and placing drawings for reinforced concrete structures" and CRSI "Manual of Standard Practice".
15. No conduit or piping larger than 1" I.D. shall be run in structural concrete members unless shown on structural drawings.
16. All pipe sleeves in concrete members shall be schedule 40 pipe unless noted otherwise on the structural drawings. Location of the sleeves shall be as approved by the Structural Engineer. Provide 3 additional stirrups each side of each sleeve in beams and space as directed by the Engineer.
17. Reinforced steel shall be deformed new billet steel bars in accordance with A.S.T.M. Specification A615 Grade 60.
18. All stirrups shall be Grade 60 steel with standard 90 degree hooks.
19. All hooks and bends in reinforcing bars shall conform to ACI Standards unless shown otherwise.
20. Reinforcement designated as "continuous" may be spliced using Type "B" splices.
21. In lieu of lap splices, rebar couplers may be used. Detailer shall account for coupler size, 24 inch staggering of couplers and reinforcement spacing. The couplers shall develop 125% of the specified yield strength of the rebar.
22. Vertical joints may occur at center of spans at locations reviewed by StructuresPE, LLP.
23. Horizontal construction joints in concrete pours shall be permitted only where indicated on the drawings. All construction joints shall be made in the center of spans - see drawings for typical detail.
The location of the construction joints shall be as approved by the Architect and the Structural Engineer. Additional reinforcing at construction joints shall be as specified by the Engineer without additional cost to the owner.
24. Construction joints between piers and pier caps, footings and walls or columns, or walls, columns, beams, and the floor system they support shall be prepared by roughening the contact surface to a full amplitude of approximately 1/4 inch leaving the contact surface clean and free of laitance.
25. Reinforcement bars shall not be tack welded, welded, heated, or cut unless indicated on the Contract Documents or approved by StructuresPE, LLP.
26. Minimum concrete cover protection for reinforcement bars shall be as follows: (see ACI 318 for conditions not noted)
Concrete exposed to weather #5 bars and smaller 1-1/2 inches All other bars 2 inches Concrete cast against earth 3 inches
Grade beams:
Top 1-1/2 inches Board formed sides 2 inches Earth formed sides 3 inches Bottom 3 inches
CONCRETE MASONRY UNITS (CMU)
1. The net area compressive strength of masonry, F'm, shall be a minimum of 1500 psi (unless noted otherwise on plan) and determined in accordance with the unit strength method.
2. Masonry units shall conform to ASTM C90 and shall be medium weight unless noted otherwise.
3. Mortar shall be type S or M and shall conform to the requirements of ASTM C270 and conform to the proportion specification table of the 2015 IBC.
4. Grout shall be coarse and conform to ASTM C476 by volumetric proportion. Slump shall be within the range of 8" to 11".
5. Reinforcing steel shall be deformed new billet steel bars in accordance with A.S.T.M. Specification A615 Grade 60. Reinforcement shall be lap spliced a minimum of 36 bar diameters unless otherwise noted. Joint reinforcement where indicated shall comply with ASTM A951.
6. Provide (1) additional scheduled vertical bar at each end, corners, and intersections of all walls as specified on the drawings.
7. All masonry cores containing vertical reinforcement shall be solid grouted. Cells to be grouted shall be clean and free of excess mortar and foreign materials.
8. Unless noted otherwise, provide continuous bond beam at all top of wall locations as well as at intermediate floor lines. Bond beams shall be grouted and reinforced with (2) continuous #4 bars. If wall is partially grouted, provide a barrier to control grout flow.
9. Control joints shall be placed in coordination with the Architect. It is recommended that the panel length to height ratio of the wall does not exceed 1.5 and that the maximum panel length does not exceed 25'-0". Additional joints should be added where abrupt changes in wall section occur. At bond beams, debond bar at joint, 8" each side from joint, tool with triangular jointer.
10. Masonry accessories are not indicated on structural drawings.
11. Refer to lintel schedule and details for masonry lintel requirements.
12. The contractor shall submit the following to the engineer of record:
A. For each mortar mix - mix designs indicating type and proportion of ingredients in compliance with the above specified requirements.
B. Grout mix designs indicating type and proportions of the ingredients according to the above specified requirements.
C. Material Certificates certifying project compliance for the following:
1. Reinforcement
2. Anchors, ties, fasteners, and metal accessories
3. Masonry Units
4. Mortar and Grout Materials
13. Quality assurance and Inspections of masonry construction shall at a minimum consist of the following:
A. As masonry construction begins, inspect the following to ensure compliance:
1. Proportions of site-prepared mortar.
2. Construction mortar joints.
3. Location of reinforcement and connectors.
B. During construction, inspect the following:
1. Size and location of structural elements.
2. Size, type, and grade of reinforcement and anchor bolts.
3. Preparation, construction, and protection of masonry during cold weather below 40° F and hot weather above 90° F.
C. Prior to grouting, inspect the following:
1. Grout spaces (prior to grouting and prior to closing cleanouts).
2. Placement of reinforcement and connectors.
3. Proportions of site-prepared grout.
4. Construction of mortar joints.
5. Grout placement and grouting operations.
D. Provide a report of each inspection.
14. The inspection agency shall furnish (but not limited to) inspection results and reports promptly to the Architect, Engineer of Record, and Contractor and a final signed report stating whether Work inspected was, to the best of the Inspection Agency's knowledge, in conformance with the Construction Documents and specifications.
CMU
HATCH LEGEND
CONCRETE
EARTH
CRUSHED GRAVEL
DECORATIVE GRAVEL
ABBREVIATIONS
ARCH ARCHITECT, ARCHITECTURAL
BOD BOTTOM OF DECK (METAL DECK ONLY)
BP BASEPLATE
CFMF COLD FORMED METAL FRAMING
CJP COMPLETE JOINT PENETRATION
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONT CONTINUOUS
DBA DEFORMED BAR ANCHOR
EJ EXPANSION JOINT
ENG ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
FFE FINISH FLOOR ELEVATION
FTG FOOTING
GT GIRDER TRUSS
HCA HEADED CONCRETE ANCHOR
HDG HOT-DIP GALVANIZED
HDR HEADER
HORIZ HORIZONTAL
HSS HOLLOW STEEL SECTION
INFO INFORMATION
KSI KIPS PER SQUARE INCH
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
LW LIGHT WEIGHT
MAX MAXIMUM
MCJ MASONRY CONTROL JOINT
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT SO SCALE
NW NORMAL WEIGHT
O.C. ON CENTER
O.H. OPPOSITE HAND
PCF POUNDS PER CUBIC FOOT
PJP PARTIAL JOINT PENETRATION
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REF REFER, REFERENCE
REINF REINFORCED, REINFORCEMENT
REQ'D REQUIRED
SIM SIMILAR
SOG SLAB ON GRADE
SQ SQUARE
SS STAINLESS STEEL
T.O. TOP OF
T.O.WALL TOP OF WALL
TOC TOP OF CONCRETE
TOD TOP OF DECK (WOOD DECKING ONLY)
TOS TOP OF STEEL
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VERT VERTICAL
WWF WELDED WIRE FABRIC
SHEET INDEX
S0 SERIES STRUCTURAL NOTES
S1 SERIES PLANS
S2 SERIES CONCRETE/CMU
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
National Cemetery
Administration
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT MANAGER STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
BURIAL EXPANSION
FORT SMITH, ARKANSAS
847CM3019
N/A
BID DOCUMENTS
APRIL 03, 2020
04.03.20
STRUCTURAL NOTES
S000
AutoCAD SHX Text
GERARD GARCIA
AutoCAD SHX Text 67435
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text X
'-7
5'-6"
1'-0" 3'-6" 1'-0"
1'-0" 1'-0"
1'-0" 1'-0"
3'-6"
3'-6"
8'-0" 5'-6" 8'-0" 5'-6" 42'-0" 5'-6" 8'-0" 5'-6" 8'-0" 5'-6"
1'-0" 3'-6" 1'-0"
1'-0" 1'-0"
1'-0" 1'-0"
3'-6"
3'-6"
'-8
/2
'-8
/2
" 21 '-7
1/S200
1/S200 1/S200 1/S200 1/S200
1/S200
2/ S2
S
IM
1 FOUNDATION PLAN
1/8" = 1'-0"
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
2/ S2
S
IM
1' -0
1'
-0
1' -0
1'
-0
1' -0
1'
-0
1' -0
1'
-0
1' -0
1'
-0
2/S200
2/S200
2/S200 2/S200
2/S200 2/S200
2/S200
2/S200
2/S200
2/S200
2/S200
1' -0
1'
-0
DECORATIVE BOLLARD
- SEE 4/S200, TYP.
- REF. ARCH FOR SIZE
& EXACT LOCATION
DECORATIVE BOLLARD
- SEE 4/S200, TYP.
- REF. ARCH FOR SIZE
& EXACT LOCATION
F O U N D A T I O N P L A N N O T E S
1. VERIFY AND COORDINATE ALL DIMENSIONS, ELEVATIONS, DROPS
AND SLOPES WITH ARCHITECTURAL PLANS.
2. TOP OF CONCRETE (TOC) ELEVATION SHALL BE VERIFIED.
3. THESE STRUCTURAL DOCUMENTS DO NOT ADDRESS WATER ISSUES
AS IT RELATES TO BUT NOT LIMITED TO SITE DRAINAGE, ROOF
RUNOFF, OR WATER INTRODUCED BY ADJACENT PROPERTIES.
ADEQUATE DRAINAGE SHALL BE PROVIDED TO LIMIT THE EFFECTS
OF EROSION AND TO MAINTAIN THE INTEGRITY OF THE
STRUCTURAL SYSTEM DESCRIBED. FOR WATERPROOFING AND
DRAINAGE REFER TO ARCHITECTURAL AND CIVIL DRAWINGS.
WATER ISSUES AND/OR WATERPROOFING ARE BEYOND THE SCOPE
OF THESE DOCUMENTS.
4. SEE S200 SHEET SERIES FOR FOUNDATION DETAILS.
5. SEE SHEET S000 FOR ADDITIONAL NOTES.
3/S200
- TYP.
3/S200
- TYP.
2/S200
3/S200
- TYP.
3/S200
- TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
National Cemetery
Administration
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT MANAGER STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
BURIAL EXPANSION
FORT SMITH, ARKANSAS
847CM3019
N/A
BID DOCUMENTS
APRIL 03, 2020
04.03.20
COLUMBARIUM FOUNDATION PLAN
S100
AutoCAD SHX Text
GERARD GARCIA
AutoCAD SHX Text 67435
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text A
COLUMBARIUM UNIT DESIGNED BY
MANUFACTURER TO SUPPORT A
MIN. OF 50 PSF LIVE LOAD AND
DEAD LOAD BASED ON CAP
THICKNESS PER SECTION 03 48 24
PRECAST CONCRETE COLUMBARIUM
UNITS SPECIFICATION PART 1.3.F2
1 SECTION AT COLUMBARIUM
3 / 4" = 1' - 0"
TO APPROVED BEARING:
24" MIN. BELOW FINAL GRADE
1"Ø UNIFORMLY GRADED
FREE DRAINING CRUSHED
ROCK OR WASHED GRAVEL
PAVING - REF. ARCH.
DECORATIVE GRAVEL
- REF. ARCH.
FRENCH DRAIN
- REF. CIVIL
8" CMU REINF. W/ #4 VERT. @ 24" O.C.
& FOR WALLS OTHER THAN RUNNING
BOND PROVIDE 9 GA. LADDER HORIZ.
REINF. SPACED @ 16" O.C.
CUT STONE CAP
- REF. ARCH.
#4 X @ 12" O.C.
MAX. EACH WAY
5'-6"
4' -0
3' -0
" M
IN
1'
-6
M
IN
1' -4
2 SECTION AT COLUMBARIUM AT CMU WALL
3 / 4" = 1' - 0"
8" CMU BOND BEAM
REINF. W/ (2) #4 CONT.
HORIZ. AT TOP - TYP.
4' -0
1'-0"#4 X DOWEL
@ 48" O.C.
REF. ARCH. FOR
FINISHES - TYP.
3 ENLARGED PLAN AT CMU END WALL
3 / 4" = 1' - 0"
1'-0" 3'-6" 1'-0"
5'-6"
1' -0
4"
1' -3
/4
2 1/4" 3'-1 1/2" 2 1/4"
VARIESVARIES
VA
RI
ES
8" CMU REINF. W/ #4
VERT. @ 24" O.C. & FOR
WALLS OTHER THAN
RUNNING BOND PROVIDE
9 GA. LADDER HORIZ.
REINF. SPACED @ 16" O.C.2/S200
1/S200
#6 X @ 10" O.C.
EACH WAY TOP & BOTTOM
2' -0
PROVIDE #5 CONT.
AT EACH FACE
#6 @ 10" O.C. TOP
& BOTTOM
4 FOOTING DETAIL AT DECORATIVE BOLLARD
3 / 4" = 1' - 0"
1'-4"
TO APPROVED BEARING:
24" MIN. BELOW FINAL GRADE
SQUARE
(4) #5 VERTICAL & #3
TIES @ 10" O.C.
(2) #5 TIES AT TOP
PAVING - REF. ARCH.
DECORATIVE CAST
ALUMINUM BOLLARD
- REF. ARCH.
ATTACHMENT PER
BOLLARD MFR. - TYP.
3' -0
VA
RI
ES
- R
EF
. A
RC
H.
TO APPROVED BEARING:
24" MIN. BELOW FINAL GRADE
1"Ø UNIFORMLY GRADED
FREE DRAINING CRUSHED
ROCK OR WASHED GRAVEL
PAVING - REF. ARCH.
DECORATIVE GRAVEL
- REF. ARCH.
FRENCH DRAIN
- REF. CIVIL
#4 X @ 12" O.C.
MAX. EACH WAY
5'-6"
4' -0
ANCHORS - REF.
COLUMBARIUM MFR
3' -0
" M
IN
1'
-6
M
IN
1' -4
1'-0"#4 X DOWEL
@ 48" O.C.
#6 X @ 10" O.C.
EACH WAY TOP & BOTTOM
2' -0
PROVIDE #5 CONT.
AT EACH FACE
#6 @ 10" O.C. TOP
& BOTTOM
VA
RI
ES
- R
EF
. A
RC
H.
CUT STONE CAP
- REF. ARCH.
1'-0" 3'-6" 1'-0" 1'-0" 3'-6" 1'-0"
2/ S2
S
IM
COLUMBARIUM FOUNDATION DETAILS
S200
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
National Cemetery
Administration
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT MANAGER STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
BURIAL EXPANSION
FORT SMITH, ARKANSAS
847CM3019
N/A
BID DOCUMENTS
APRIL 03, 2020
04.03.20
AutoCAD SHX Text
GERARD GARCIA
AutoCAD SHX Text 67435
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text A
File details come from the government source that posted it. Updated .