S06 - 0003 - Att 3 - Addendum 1- Drawings Combined.pdf

PDF 22 MB Posted

Attached to
Construct EHRM Infrastructure Upgrades | Lebanon, PA Federal contract opportunity
Solicitation number
36C77625R0055_1
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This file contains door schedule and technical specifications for a telecommunications room upgrade at the Lebanon VA Medical Center. The detailed drawing provides comprehensive information about door types, frame types, hardware requirements, and security specifications for multiple buildings across the facility.

Key details include door dimensions predominantly at 3' wide by 7' or 8' tall, with specific requirements for fire ratings, hardware, and security features. Each door is assigned a unique identifier and must adhere to VA infrastructure standards, such as telecommunications space doors being a minimum of 8' tall (with some approved exceptions). Security requirements mandate dual authentication card readers, door contacts, fixed and pan/tilt/zoom cameras, duress alarms, and integration with physical access control systems. The document covers door specifications for Buildings 01, 02, 17, 18, 19, 22, 23, 35, and 37, with meticulous attention to installation details, frame types, and security protocols.

View the file

Other files for this federal contract opportunity

Other files attached to Construct EHRM Infrastructure Upgrades | Lebanon, PA, newest first.
File Type Posted
S06 - 0007 - Att1 - Wage Determination.txt TXT text file
S06 - 0007 - 36C77625R0055 0007.pdf PDF
S06 - 0006 - Att2 - Addendum 2 - Maxcell 4-cell Innerducts.pdf PDF
S06 - 0006 - Att1 - Addendum 2 - Narrative.pdf PDF
S06 - 0006 - 36C77625R0055 0006.pdf PDF
S06 - 0005 - Att 4 - Addendum 1 - INTRUSION DETECTION.pdf PDF
S06 - 0005 - Att 3 - Addendum 1 - Drawings Combined.pdf PDF
S06 - 0005 - Att 5 - Addendum 1 - VIDEO SURVEILLANCE.pdf PDF
S06 - 0005 - Att 2 - Addendum 1 - Narrative.pdf PDF
S06 - 0005 - Att 1 - Addendum 1 - ToC.pdf PDF
S06 - 0005 - Att 6 - Wage Determination.txt TXT text file
S06 - 0005 - 36C77625R0055 0005.pdf PDF
S06 - 0004 - Att1 - Post Deadline Vendor QA Responses 7.14.25.xlsx XLSX spreadsheet
S06 - 0004 - 36C77625R0055 0004.pdf PDF
S06 - 0003 - 36C77625R0055 0003.pdf PDF
S06 - 0003 - Att 2 - Addendum 1- Narrative.pdf PDF
S06 - 0003 - Att 1 - Addendum 1 - Table of Contents.pdf PDF
S06 - 0003 - Att 5 - Addendum 1 - VIDEO SURVEILLANCE.pdf PDF
S06 - 0003 - Att 4 - Addendum 1 - INTRUSION DETECTION.pdf PDF
S06 - 0002 - Vendor QA.xlsx XLSX spreadsheet
S06 - 0002 - 36C77625R0055.pdf PDF
S06 - 0001 - Site Visit Sign-In Sheet.pdf PDF
S06 - 0001 - Site Visit Agenda.doc DOC document
S06 - 0001 - 36C77625R0055.pdf PDF
S02 - Att8 - Limitations on Subcontracting Cert.pdf PDF
S02 - 36C77625R0055.pdf PDF
S02 - Att6 - Wage Determination.txt TXT text file
S02 - Att9 - Redacted JA.pdf PDF
S02 - Att4 - Drawings - Vol 2.pdf PDF
S02 - Att7 - Design Alert - All.pdf PDF
S02 - Att1 - CD Specs - Vol.1.pdf PDF
S02 - Att2 - CD Specs - Vol.2.pdf PDF
S02 - Att3 - Drawings - Vol 1.pdf PDF
S02 - Att5 - Drawings - Vol 3.pdf PDF
Show all 34

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR TYPES

FRAME TYPES

AS SCHEDULED

A S

S C

H E

D U

LE

D

TYPE F

GENERAL NOTE:

1. SEE DOOR SCHEDULE FOR FIRE RATING

2. PAINT ALL HOLLOW METAL DOOR AND FRAME

AS SCHEDULED

A S

S C

H E

D U

LE

D

TYPE 1

2" T

Y P

AS SCHEDULED

A S

S C

H E

D U

LE

D

TYPE 2

4" T

Y P

AS SCHEDULED

A S

S C

H E

D U

LE

D

TYPE FG

1. COORDINATE ALL DOOR HARDWARE AND DOOR SECURITY REQUIREMENTS LISTED IN

HARDWARE SCHEDULE WITH TECHNOLOGY, SECURITY, AND ELECTRICAL DRAWINGS.

DOORS SHALL HAVE 1/2" UNDERCUT UNLESS NOTED OTHERWISE IN THE CONSTRUCTION

DOCUMENTS.

2. FRAME OPENINGS INDICATED FINISHED SIZE OF FRAMES. COORDINATE ROUGH OPENINGS

TO INCLUDE INSTALLATION TOLERANCES.

3. SEE HOLLOW METAL FRAME TYPES AND DOOR TYPES ON THIS SHEET FOR ELEVATIONS

OF FRAMES, DOORS AND GLAZING IN DOOR OPENINGS.

4. "C" LABEL FIRE RATED DOORS SHALL BE RATED FOR 45 MINUTES

5. DOOR CLOSERS SHALL BE ADJUSTED TO REQUIRE NO MORE THAN 5 POUNDS PER

SQUARE FOOT OF OPENINGS FORCE TO OPEN DOORS.

DOOR SCHEDULE GENERAL NOTES

PER THE INFRASTRUCTURE STANDARDS FOR TELECOMMUNICATIONS SPACES VERSION 3.1,

TABLE 4.1.1- DOORS TO TELECOMMUNICATION SPACES SHALL BE 8'-0" IN HEIGHT MINIMUM. NEW

DOORS SHOWN IN DOOR SCHEDULE AS 7'-0" HAVE BEEN APPROVED BY AN EXCEPTION MEMO

AND CAN BE REFERENCED IN THE EXCEPTION MEMORANDUM OF THE CONTRACT DOCUMENTS.

DOOR HEIGHT EXCEPTION NOTE

1. ALL LOCKS FOR DOORS INTO NEW MCR AND NEW SWITCHGEAR SHALL BE FIELD

SELECTABLE FAIL SAFE/FAIL SECURE. THE TERM FAIL SECURE INDICATES THE LOCK WILL

REMAIN SECURE WHEN IN FAIL MODE. FAIL SECURE SHALL ALWAYS PERMIT EMERGENCY

EGRESS FUNCTIONS OF THE LOCK. IN THESE CIRCUMSTANCES A BYPASS FEATURE SHALL

BE PROVIDED TO ALLOW ACCESS FROM THE UNSECURE SIDE. MAGNETIC LOCKS SHALL

NOT FAIL SECURE.

DOOR HARDWARE GENERAL NOTE

WALL THICKNESS

COORD W/

2"

VARIES

SCHEDULED

PARTITION TYPE

METAL TRACK

METAL STUD BOX

HEADER

SEALANT TYP. BOTH

SIDES, FULL PERIMETER

JAMB ANCHOR

W A

LL

T

H

IC

K N

E S

S

C O

O R

D W

MIN

4"

2"

V A

R

IE

S

SEALANT TYP. BOTH SIDES,

FULL PERIMETER

JAMB ANCHOR

DOOR

DOOR FRAME

SCHEDULED PARTITION

TYPE SEE PLAN AND

WALL TYPE SHEET

EXISTING CMU WALL AND

LINTEL- VERIFY IN FIELD

5/ 8"

S E

E F

R A

M E

T Y

P E

VARIES

COORD. W/ WALL THICKNESS

BACKER ROD & SEALANT- BOTH

SIDES, TYP

HOLLOW METAL FRAME

EXISTING CMU WALL AND

LINTEL- VERIFY IN FIELD

C O

O R

D . W

/ W A

LL

T

H

IC

K N

E S

S

2" 5/8"

4" MIN. UON

SEALANT, BOTH SIDES, TYP-

FULL PERIMETER

JAMB ANCHOR

HOLLOW METAL FRAME

SDO217

• CARD READER- W/ BIOMETRIC OR PIN

IDENTIFICATION RETRACTS ELECTRIC STRIKE

• DOOR CLOSER

• CONTINUOUS HINGE

• DOOR CONTACT

• ELECTRIC STRIKE

• FLUSH BOLTS (IF DOUBLE DOORS- SEE SCHED)

• MORTISE LOCK- LOCKSET TYPE SHALL BE IN

ACCORDANCE WITH ANSI/BMHA F07

STOREROOM FUNCTION

• DOOR MONITOR SHALL BE ALARMED TO

CENTRAL MONITORING SYSTEM

• KICK PLATE

• SILENCERS

DOOR HARDWARE SCHEDULE & SECURITY REQUIREMENTS

SDO218

• CONTINUOUS HINGE

• FLUSH BOLTS (IF DOUBLE DOORS- SEE SCHED)

• MORTISE LOCK- LOCKSET SHALL BE IN

ACCORDANCE WITH ANSI/BMHA F07

STOREROOM FUNCTION

• DOOR CLOSER

• KICK PLATE

• SILENCERS

SDO228

• CARD READER- RELEASES STRIKE OR

COMBINATION LOCK RETRACKS LATCHBOLT

• CLOSER

• CONTINUOUS HINGE

• DOOR CONTACT

• ELECTRIC STRIKE

• FLUSH BOLTS (IF DOUBLE DOORS- SEE SCHED)

• MORTISE LOCK

• DOOR MONITOR ALARMED TO CENTRAL

MONITORING STATION

• SILENCERS

• KICK PLATE

SECURITY REQUIREMENTS PER VA PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL (SEE ALL CONSULTANTS SHEETS FOR ADDITIONAL REQUIREMENTS & DETAILS)

ALL NEW DOORS TO NEW TR ROOMS AND NEW MCR SHALL BE PROVIDED WITH THE VA REQUIRED MINIMUM SECURITY SYSTEMS:

1. DUAL AUTHENTICATION CARD READER (CARD AND PIN)

2. DOOR CONTACT

3. FIXED CAMERA, PAN/TILT/ZOOM, PASSIVE INFRARED CAMERA- DUAL TECHNOLOGY

4. DURRESS/PANIC ALARM/ MONEY CLIP

5. PUBLIC ADDRESS/ MASS NOTIFICATION SYSTEM

6. SCC/IOC/EOC MONITORING (LOCAL OR REGIONAL) OF PHYSICAL ACCESS CONTROL SYSTEM (PACS), INTRUSION DETECTION SYSTEM (IDS), SECURITY SURVEILLANCE TELEVISION (SSTV), DURESS SECURITY PHONES AND INTERCOM SYSTEM (DSPI)

PER VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL

PROVIDE HORIZONTAL BRACE IF

SCREEN HEIGHT EXCEEDS 52"

2 1/2" OPENING WIDTH 2 1/2"

FRAME WIDTH

1/

2" O

P E

N

IN

G H

E

IG

H T

1/

2"

FR

A

M E

H E

IG

H

T

12 X 12 SCREEN MESH,

SS 304, 0.028" THICK, TYP

12 GA. STEEL FRAME, TYP

WELDED CORNERS, TYP

13 GA. CONCEALED HINGES

@ 24" O.C. MAX (2 HINGES

MIN.), TYP

BIT KEY LOCK, TYP

FRAME WIDTH

2 1/2" OPENING WIDTH 2 1/2"

FR

A

M E

H E

IG

H

T

1/ 2"

O P

E N

IN

G

H E

IG

H

T

1/

2"

SINGLE WINDOW FRAME W/ MULLION-

WHERE REQUIRED

EXTERIOR

INTERIOR

12 GA. STEEL MAIN FRAME, TYP

FASTENER PER MANUF'S

RECOMMENDATIONS, TYP

12 X 12 SCREEN MESH, SS

304, 0.028" THICK, TYP

2 1/2"

O P

E N

IN

G

H E

IG

H

T

1/ 2"

1/

2"

PROVIDE HORIZONTAL BRACE IF

SCREEN HEIGHT EXCEEDS 52"

SILL

HEAD

BRACE

FASTENER PER MANUF'S

RECOMMENDATIONS, TYP

12 GA. STEEL SUB-FRAME, TYP

2 1/2"

12 GA. STEEL SUB-FRAME

12 X 12 SCREEN MESH, SS

304, 0.028" THICK, TYP

12 GA. STEEL MAIN FRAME

EXISTING WINDOW, TYP- VERIFY

IN FIELD

EXISTING EXTERIOR WALL

CONSTRUCTION, TYP- VERIFY IN

FIELD

EXISTING EXTERIOR WALL

CONSTRUCTION, TYP- VERIFY IN

FIELD

EXISTING WINDOW, TYP-

VERIFY IN FIELD

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

LTCAL

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

DOOR SCHEDULES AND OPENING

DETAILS

AE600

-2

-7

A E

.p d f

DOOR SCHEDULE

DOOR NO.

DOOR FRAME DOOR

LABEL

FIRE

RATING

HARDWARE

SET REMARKS

NOMINAL SIZE

TYPE MATL MATL TYPE

SECTIONS

WIDTH HEIGHT THK. JAMB HEAD

BUILDING 01

230A 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G13/01-AE604 A7/01-AE604 SDO218 SECURITY REQS IN HARDWARE SCHED

340A 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G13/01-AE604 A13/01-AE604 SDO218 SECURITY REQS IN HARDWARE SCHED

400C 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G13/01-AE604 A13/01-AE604 SDO218 SECURITY REQS IN HARDWARE SCHED

539 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G13/01-AE604 A13/01-AE604 SDO218 SECURITY REQS IN HARDWARE SCHED

6B 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

27A 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

155 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

16A 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 NEW DOOR TO EXISTING STORAGE ROOM

BUILDING 02

103 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 10

106B 3' - 0" 8' - 0" 1 3/4" F HM HM 1 D10/AE600 D7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 17

236A 3' - 0" 7' - 0" 1 3/4" F HM HM 1 A10/17-AE603 E10/17-AE603 SDO218 SECURITY REQS IN HARDWARE SCHED

442F 3' - 0" 7' - 0" 1 3/4" F HM HM 1 A10/17-AE603 E10/17-AE603 SDO218 SECURITY REQS IN HARDWARE SCHED

549B 3' - 0" 7' - 0" 1 3/4" F HM HM 1 A10/17-AE603 E10/17-AE603 SDO218 SECURITY REQS IN HARDWARE SCHED

122A 3' - 0" 8' - 0" 1 3/4" F HM HM 2 A5/17-AE603 E5/17-AE603 SDO218 SECURITY REQS IN HARDWARE SCHED

339B 3' - 0" 7' - 0" 1 3/4" F HM HM 1 A10/17-AE603 E5/17-AE603 SDO218 SECURITY REQS IN HARDWARE SCHED

102A 6' - 0" 7' - 0" 1 3/4" HM HM 2 A15/17-AE603 E15/17-AE603 NEW DOUBLE DOOR TO BASEMENT. ONE PANEL SHALL BE

4'-0" (W) AND ONE PANEL SHALL BE 2-0" (W)

BUILDING 18

123 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

350 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

402 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

530 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

280 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

14 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

349A 2' - 6" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 NEW DOOR TO EXISTING CLOSET

BUILDING 19

132F 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

227 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

323 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 22

317 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

106A 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

244 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 23

101A 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 35

C119 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 37

1A23 3' - 0" 7' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

2A08K 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 104

1404 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

272 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/AE600 SDO218 SECURITY REQS IN HARDWARE SCHED

BUILDING 136

136A 6' - 0" 8' - 0" 1 3/4" HM HM 2 C5/136-AE401b A8/136-AE502 45 MIN. SDO217 SECURITY REQS IN HARDWARE SCHED

136B 6' - 0" 8' - 0" 1 3/4" HM HM 2 C5/136-AE401b A8/136-AE502 45 MIN. SDO217 SECURITY REQS IN HARDWARE SCHED

136C 3' - 0" 8' - 0" 1 3/4" F HM HM 1 G10/AE600 G7/E600 45 MIN SDO217 SECURITY REQS IN HARDWARE SCHED

3" = 1'-0"G7

NEW DOOR HEAD IN MTL STUD WALL

3" = 1'-0"G10

NEW DOOR JAMB IN MTL STUD WALL

3" = 1'-0"D7

NEW DOOR HEAD DETAIL IN EXISTING CMU

3" = 1'-0"D10

NEW DOOR JAMB DETAIL IN EXISTING CMU

3/4" = 1'-0"A9

WINDOW SECURITY SCREEN- ELEVATION

6" = 1'-0"A16

WINDOW SECURITY MESH DETAILS

Revisions: Date

ADDENDUM 1 07.03.2025

IT CLOSET

G011

M

IT CLOSET

G011

IT

CLOSET

25B

M

IT

CLOSET

25B

01-TD400

G5

EXISTING TTB

2- POST EQUIPMENT RACK

VERTICAL WIRE MANAGER

(TYP.)

EXISTING WALL MOUNTED

SWITCHES

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW EQUIPMENT IS ACTIVE AND DEVICES RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM. REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE.

DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF TELECOM ROOM, REMOVE EXISTING FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTRIBUTION PANEL IN NEW RACK TO SWITCHES IN EXISTING

RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READERS AND DEVICES. PROVIDE NEW NETWORK CONNECTION

FROM NEW TR SERVING THIS AREA.

5. MANTAIN EXISTING PLYWOOD BACKBOARDS, SLEEVES, AND PATHWAYS. PATCH ALL HOLES AND OPENINGS IN WALLS/FLOORS TO

MATCH EXISTING SURFACE.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN EXISTING

TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO DISCONNECTING ANY

CABLING IN THIS ROOM.

6 1

EXISTING LADDER RACK

(TYP.)

KEYNOTES:

1. MAINTAIN CEILING AND WALL MOUNTED LADDER RUNWAYS, CABLE PATHWAYS, SLEEVES AND ALL MOUNTED

HARDWARE. PATCH ALL HOLES AND OPENING TO MATCH EXISTING SURFACE.

VA NETWORK SW.

EX. FIBER DISTR

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

CABLE MGR

EX. NETWRK SW

EX. NETWRK SW

EX. NETWRK SW

EX. UPS/BATT

SPACE

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW EQUIPMENT IS ACTIVE AND DEVICES RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM.

REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-6A, REMOVE EXISTING FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTRIBUTION PANEL IN NEW RACK TO SWITCHES IN

EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READERS AND DEVICES. PROVIDE NEW NETWORK

CONNECTION FROM NEW TR SERVING THIS AREA.

5. MANTAIN EXISTING PLYWOOD BACKBOARDS, SLEEVES, AND PATHWAYS. PATCH ALL HOLES AND OPENINGS IN WALLS/FLOORS

TO MATCH EXISTING SURFACE.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO DISCONNECTING

ANY CABLING IN THIS ROOM.

-T

D

B5

VERTICAL WIRE MANAGER

(TYP.)

EXISTING WALL MOUNTED

SWITCHES

EXISTING EQUIPMENT RACK

EXISTING TTB

KEYNOTES:

1. MAINTAIN EXISTING CEILING AND WALL MOUNTED LADDER RUNWAYS, CABLE PATHWAYS, SLEEVES AND ALL MOUNTED HARDWARE COMPLETE. PATCH ALL HOLES AND OPENING TO MATCH EXISTING SURFACE.

18"x4"

LADDER RACK (TYP.)

"x

EX. FIBER DISTR.

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

EX. NETWRK SW

EX. NETWRK SW

EX. NETWRK SW

EX. UPS/BATT

SPACE

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - TECHNOLOGY DEMO

ENLARGED PLANS

01-TD400

-2

-7

-T

D

/2

/2

.p d f

N O R

HT

1/4" = 1'-0"

EXISTING EQUIPMENT ENLARGEMENT ROOM TR-#GO11

G15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #G011 PATHWAY

G11

1" = 1'-0"

EXISTING RACK ELEVATION TR-#G011

G5

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #25B ENLARGEMENT

B15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #25B PATHWAY

B11

1" = 1'-0"

EXISTING RACK ELEVATION TR-#25B

B5

ADDENDUM #1 06/27/2025

CHASE

M

CHASE

CHASE

200A

UTILITY RM

IT

CLOSET

UTILITY RM

IT

CLOSET

200A

D

200A

UTILITY RM

IT

CLOSET

UTILITY RM

IT

CLOSET

200A

01-TD401

G5

EXISTING TTB

2-POST EQUIPMENT RACK

VWM (TYP.)

EXISTING ACCESS

CONTROL PANEL

110 BLOCKS

FIBER CABINETS

FIBER CABINETS

WALL MOUNTED

SWITCHES

EXISTING FIRE ALARM

CONTROL PANEL

EXISTING ACCESS

CONTROL PANEL

2 3

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW TELECOM ROOM IS ACTIVE AND RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM.

REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-155, REMOVE FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTR. PANEL IN NEW EQUIPMENT RACKS TO NETWORK

SWITCHES IN EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READER. AND DEVICES.

5. MAINTAIN EXISTING PLYWOOOD BACKBOARDS. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING SURFACES.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO

DISCONNECTING ANY CABLING IN THIS ROOM.

KEYNOTES:

1. MAINTAIN EXISTING CEILING AND WALL MOUNTED LADDER RUNWAY, CABLE PATHWAYS AND SLEEVES. PATCH

ALL HOLES AND WALL/CEILING OPENINGS TO MATCH EXISTING SURFACE

EXISTING 12" WIDE

LADDER RUNWAY

EX. CABLE MGR

EX. CABLE MGR

VA NETWORK SW.

VA NETWORK SW.

VA NETWORK SW.

VA NETWORK SW.

EX. UPS/BATT

EX. FIBER DISTR.

EX. FIBER DISTR.

EX. CABLE MGR

EX. PATCH PANEL

EX. CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

EX. CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

VA NETWORK SW.

VA NETWORK SW.

EX. CABLE MGR

EX. PATCH PANEL

VA NETWORK SW.

VA NETWORK SW.

SPACE

EX. PATCH PANEL

EX. CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

01-TD401

B5

EXISTING TTB

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW TELECOM ROOM IS ACTIVE AND RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM.

REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-155, REMOVE COPPER AND FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTR. PANEL IN NEW EQUIPMENT RACKS TO NETWORK

SWITCHES IN EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READER. AND DEVICES.

5. MAINTAIN EXISTING PLYWOOOD BACKBOARDS. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING SURFACES.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO

DISCONNECTING ANY CABLING IN THIS ROOM.

EXISTING PAT.

MONITOR EQ.

1 2 3

110 BLOCKS

EXISTING WALL

MTD SWITCHES

EXISTING FIRE ALARM

CONTROL PANEL

2-POST RACKS

EXISTING 12" WIDE

LADDER RUNWAY

KEYNOTES:

1. MAINTAIN EXISTING CEILING AND WALL MOUNTED LADDER RUNWAY, CABLE PATHWAYS AND SLEEVES. PATCH

ALL HOLES AND WALL/CEILING OPENINGS TO MATCH EXISTING SURFACE

EX. FIBER DISTR

EX. CABLE MGR

CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

EX. CABLE MGR

VA NETWORK SW.

VA NETWORK SW.

VA NETWORK SW.

SPACE

EX. UPS/BATT

EX. FIBER DISTR

EX. PATCH PANEL

EX. PATCH PANEL

EX. CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

VA NETWORK SW.

SPACE

SPACE

SPACE

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - TECHNOLOGY DEMO

ENLARGED PLANS

01-TD401

-2

-7

-T

D

/2

/2

.p d f

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #129 ENLARGEMENT

G15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #129 PATHWAY

G10 1" = 1'-0"

EXISTING RACK ELEVATION TR-#129

G5

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #261 ENLARGEMENT

B15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #261 PATHWAY

B10 1" = 1'-0"

EXISTING RACK ELEVATION TR-#261

D

D

M

UNISEX TOILET

HAC

IT

CLOSET

UNISEX TOILET

UNISEX TOILET

HAC

UNISEX TOILET

HAC

D

V

D

M

D

UNISEX TOILET

HAC

01-TD402

G5

EXISTING TTB

(2) EXISTING WALL MOUNTED

RACKS

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW TELECOM ROOM IS ACTIVE AND RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM.

REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-300A, REMOVE FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTR. PANEL IN NEW EQUIPMENT RACKS TO NETWORK

SWITCHES IN EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READER. AND DEVICES.

5. MAINTAIN EXISTING PLYWOOOD BACKBOARDS. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING SURFACES.

6. MAINTAIN OPERATION OF EXISTING FIRE ALARM CONTROL PANEL AND DEVICES.

7. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO

DISCONNECTING ANY CABLING IN THIS ROOM.

EXISTING FIRE ALARM

CONTROL PANEL

EXISTING WALL MOUNTED

SWITCHES 110 BLOCKS

EXISTING CATV

1 2 3

EXISTING 12" WIDE

LADDER RUNWAY

KEYNOTES:

1. MAINTAIN EXISTING CEILING AND WALL MOUNTED LADDER RUNWAY, CABLE PATHWAYS AND SLEEVES. PATCH

ALL HOLES AND WALL/CEILING OPENINGS TO MATCH EXISTING SURFACE

01-TD402

B5

EXISTING TTB

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW TELECOM ROOM IS ACTIVE AND RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM. REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-400A, REMOVE FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTR. PANEL IN NEW EQUIPMENT RACKS TO NETWORK

SWITCHES IN EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READER. AND DEVICES.

5. MAINTAIN EXISTING PLYWOOOD BACKBOARDS. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING SURFACES.

6. MAINTAIN OPERATION OF EXISTING FIRE ALARM CONTROL PANEL AND DEVICES.

7. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO

DISCONNECTING ANY CABLING IN THIS ROOM.

EXISTING FIRE ALARM

CONTROL PANEL

EXISTING NURSE CALL

1 2 3

(2) EXISTING WALL MOUNTED RACKS

12"x4"

"x

EXISTING 12" WIDE

LADDER RUNWAY

KEYNOTES:

1. MAINTAIN EXISTING CEILING AND WALL MOUNTED LADDER RUNWAY, CABLE PATHWAYS AND SLEEVES. PATCH

ALL HOLES AND WALL/CEILING OPENINGS TO MATCH EXISTING SURFACE

EX. PATCH PANEL

EX. PATCH PANEL

VA NETWORK SW.

VA NETWORK SW.

VA NETWORK SW.

SPACE

VA NETWORK SW.

SPACE

VA NETWORK SW.

SPACE

EX. CABLE MGR

EX. PATCH PANEL

EX. PATCH PANEL

VA NETWORK SW.

VA NETWORK SW.

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - TECHNOLOGY DEMO

ENLARGED PLANS

01-TD402

-2

-7

-T

D

/2

/2

.p d f

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #353 ENLARGEMENT

G15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #353 PATHWAY

G10

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #461 ENLARGEMENT

B15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #461 PATHWAY

B10

1" = 1'-0"

EXISTING RACK ELEVATION TR-#353

G5

1" = 1'-0"

EXISTING RACK ELEVATION TR-#461

UNISEX TOILET

D

V

M

UNISEX TOILET

CHASE

HAC

616ACSS

CHASE

HAC

616A

01-TD403

G5

EXISTING TTB

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW TELECOM ROOM IS ACTIVE AND RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM.

REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-572A, REMOVE FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTR. PANEL IN NEW EQUIPMENT RACKS TO NETWORK

SWITCHES IN EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READER. AND DEVICES.

5. MAINTAIN EXISTING PLYWOOOD BACKBOARDS. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING SURFACES.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO

DISCONNECTING ANY CABLING IN THIS ROOM.

EXISTING FIRE ALARM

CONTROL PANEL

EXISTING FIBER

PANEL/110 BLOCKS

EXISTING ACCESS

CONTROL PANEL

(2) EXISTING

EQUIPMENT RACK 1 2 3

KEYNOTES:

1. REMOVE EXISTING PATHWAYS AND SLEEVES. PATCH ALL HOLES AND WALL/CEILING OPENINGS TO MATCH

EXISTING SURFACE.

-T

D

B5

EXISTING TTB

EXISTING EQUIPMENT RACK

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW TELECOM ROOM IS ACTIVE AND RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM. REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-572A, REMOVE FIBER BACKBONE CABLING COMPLETE BACK TO DATA CENTER.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTR. PANEL IN NEW EQUIPMENT RACKS TO NETWORK

SWITCHES IN EXISTING RACKS.

4. MAINTAIN OPERATION OF EXISTING ACCESS CONTROL PANEL, CARD READER. AND DEVICES.

5. MAINTAIN EXISTING PLYWOOOD BACKBOARDS. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING

SURFACES.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN

EXISTING TELECOM ROOM SHALL REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO

DISCONNECTING ANY CABLING IN THIS ROOM.

1 2 3

EXISTING FIRE ALARM

CONTROL PANEL

KEYNOTES:

1. REMOVE EXISTING PATHWAYS AND SLEEVES. PATCH ALL HOLES AND WALL/CEILING OPENINGS TO MATCH

EXISTING SURFACE.

VA NETWORK SW.

VA NETWORK SW.

EX. PATCH PANEL

EX. PATCH PANEL

VA NETWORK SW.

VA NETWORK SW.

VA NETWORK SW.

VA NETWORK SW.

EX. PATCH PANEL

EX. PATCH PANEL

VA NETWORK SW.

VA NETWORK SW.

SPACE

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - TECHNOLOGY DEMO

ENLARGED PLANS

01-TD403

-2

-7

-T

D

/2

/2

.p d f

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #561 ENLARGEMENT

G15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #561 PATHWAY

G10

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #616A ENLAREMENT

B15

N O R

HT

1/4" = 1'-0"

EXISTING TELECOM ROOM TR #616A PATHWAY

B10

1" = 1'-0"

EXISTING RACK ELEVATION TR-#561

G5

1" = 1'-0"

EXISTING RACK ELEVATION TR-#616A

Telecom

M

Telecom01-TD404 G5

VERTICAL WIRE MANAGER

(TYP.)

EXISTING WALL MOUNTED

SWITCHES

EX. FIBER DISTR.

EXISTING TTB

KEYNOTES:

1. RE-CABLE EXISTING TELECOM OUTLETS AND NETWORK DEVICES FED FROM THIS ROOM WITH NEW CAT6A CABLES FROM NEW TELECOM ROOM. AFTER NEW EQUIPMENT IS ACTIVE AND DEVICES RE-CABLED, REMOVE EXISTING VOICE AND DATA CABLING FROM OUTLETS AND NETWORK DEVICES COMPLETE BACK TO WALL/RACK MOUNTED TELECOM EQUIPMENT IN THIS ROOM. REMOVE EXISTING EQUIPMENT RACK, FIBER DISTRIBUTION, CABLE MANAGERS, PATCH PANELS, PUNCHDOWN BLOCKS, PDUs, ETC. COMPLETE. DELIVER NETWORK SWITCHES AND UPSs TO OWNER AS SPARES.

2. AFTER ACTIVATION OF #TR-6A, REMOVE EXISTING COPPER AND FIBER BACKBONE CABLING COMPLETE BACK TO ANALOG PHONE DISTRIBUTION EQUIPMENT AND

DATA CENTER, RESPECTIVELY.

3. PROVIDE NEW TEMPORARY OPTICAL FIBER JUMPERS FROM FIBER DISTRIBUTION PANEL IN NEW RACK TO SWITCHES IN EXISTING RACKS.

4. REMOVE ACCESS CONTROL CARD READER, RTE, PTE, DOOR CONTACTS AND CABLES COMPLETE BACK TO ACCESS CONTROL SYSTEM PANELS THAT SERVES

THIS ROOM. DELIVER ALL COMPONENTS TO OWNER AS SPARES.

5. REMOVE EXISTING PLYWOOOD BACKBOARDS, CABLE SLEEVES AND PATHWAYS COMPLETE. PATCH ALL HOLES, CEILING/WALL OPENINGS TO MATCH EXISTING

SURFACES.

6. EXISTING VIDEO SURVEILLANCE, ACCESS CONTROL, FIRE ALARM, CATV AND BAS SYSTEMS AND DEVICES LOCATED WITHIN EXISTING TELECOM ROOM SHALL

REMAIN, INCLUDING ALL BACKBONE AND INTERCONNECTING CABLES REQUIRED TO MAINTAIN FULL OPERATIONS OF THESE SYSTEMS. COORDINATE WORK WITH EACH SYSTEM'S VENDOR AND VA PRIOR TO DISCONNECTING ANY CABLING IN THIS ROOM.

EXISTING LADDER

RACK (TYP.)

KEYNOTES:

1. REMOVE EXISTING CEILING AND WALL MOUNTED LADDER RUNWAYS, CABLE PATHWAYS, SLEEVES AND ALL MOUNTED HARDWARE

COMPLETE. PATCH ALL HOLES AND OPENING TO MATCH EXISTING SURFACE.

EX. FIBER DISTR.

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

EX. PATCH PANEL

CABLE MGR

EX. NETWRK SW

EX. NETWRK SW

EX. NETWRK SW

EX. UPS/BATT

EX. PATCH PANEL

EX. NETWRK SW

EX. NETWRK SW

EX. NETWRK SW

CABLE MGR

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - TECHNOLOGY DEMO

ENLARGED PLANS

01-TD404

-2

-7

-T

D

/2

/2

.p d f

N O R

HT

1/4" = 1'-0"

EXISTING EQUIPMENT ENLARGEMENT TR-GROUND FLOOR AREA C

G15

N O R

HT

1/4" = 1'-0"

PATHWAY ENLARGEMENT TR-GROUND FLOOR AREA C

G10 1" = 1'-0"

EXISTING RACK ELEVATION TR-GROUND FLOOR AREA-C

G5

F.A.C

CABINET

ELECTRICAL

400C1C 400C1B 247

C4-15

400C3

400C5

480A

480 479

C4-13 C4-13A

479A 478A

477A

476A 476

474474A

473A

C4-10 C4-10A

466A

467A

NO. 3

NO.

455A

457A

452A

453B 453C

453A

460 461

400C4

485A

490B

429 428

400C1D

418 417

411 410

408 407

406 405

438 443

445 446

NO. 2

400C2

400C1A

C4-11

C4-12C4-14489

440439

C4-1F

C4-1E

490A

470469

CORRIDOR CORRIDOR CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

DAY ROOM

THERAPY

STORAGE

WAITING

EQUIP STORAGE

HAC

LAUNDRY

BATH RM

BED RM - 2BED BED RM - 1BED

HAC HAC

BATH RM BATH RM

BED RM - 2BED

BATH RM

BED RM - 2BED

BATH RM BED RM - ISOLATION

ANTE RM

BED RM - ISOLATIONBATH RM

BED RM - 2BED

BATH RM

CLEAN

UTILITY

STAIR HALL SOILED UTILITY

ALCOVE ALCOVE

BED RM - 2BED

BATH RM

MEDICATION RM

NURSE

STATION

NOURISHMENT

CONFERENCESTAFF

LOUNGE

STAIR HALL

BATH RM

BED RM - 2BED

SERVICE

ELEVATOR

PUBLIC

ELEVATOR

STAIR HALL

STAIR HALL

WOMEN TOILET

VESTIBULE

MEN

LOCKER

ENTRY

MENS

TOILET

PIPE CHASE

HAC

CONFERENCE

OFFICE

HAC HAC

OFFICE

STAIR

OFFICE

HOSPICE

PATIENT RM

UNISEX TOILET

HAC

CORRIDOR

EQUIP

STORAGE

HOSPICE

PATIENT ROOM

BED RM - 1BED

BATH RM

BED RM - 1BED

BED RM - 1BED

BATH RM

BED RM - 1BED BED RM - 1BED

BATH RM BED RM - 1BED

NURSE STATION

LOUNGE

MEDICATION RM

BED RM - 1BED

CORRIDOR

BATH RM

BED RM - 2BED

BATH RM

BED RM - 1BED BED RM - 1BED

BATH RM

BATH RM

BED RM - 1BED

STORAGE

BED RM - 1BED BATH RM

LAUNDRY

NURSE

OFFICE

CLEAN

STORAGE

CLEAN

UTILITY SOILED UTILITY

STAFF

TOILET

BREAK RM

VESTIBULE

STAFF

LOCKERS

OFFICE

BED RM - 1BED

BATH RM

BATH RM

BED RM - 2BED DAY ROOM

BED RM - 1BED BATH RM

SERVICE LOBBY

CLEAN

UTILITY

BED RM - 1BED

PUBLIC

ELEVATOR

ELEVATOR LOBBY

CORRIDOR

BED RM - 2BED

CHARTING

CHARTINGCHARTING

STAFF

TOILET

ELECTRICAL CLOSETELECTRICAL CLOSET

ELECTRICAL CLOSET

ELECTRICAL CLOSET

PATIENT TOILET

ELECTRICAL CLOSETELECTRICAL CLOSET

UPUP

DN

UP DN

UP

DN

UP UP

DN

NEW TR-

PROPOSED

TOWER

ADDITION

400C1C 400C1B 247

C4-15

400C3

400C5

480A

480 479

C4-13 C4-13A

479A 478A

477A

476A 476

474474A

473A

C4-10 C4-10A

466A

467A

NO. 3

NO.

455A

457A

452A

453B 453C

453A

460 461

400C4

485A

490B

429 428 427 426

400C1D

418 417

411 410

408 407

406 405

438 443

445 446

NO. 2

400C2

400C1A

C4-11

C4-12C4-14489

440439

C4-1F

C4-1E

490A

470469

UPUP

DN

UP DN

UP

DN

UP UP

DN

CORRIDOR CORRIDOR CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

DAY ROOM

THERAPY

STORAGE

WAITING

EQUIP STORAGE

HAC

LAUNDRY

BATH RM

BED RM - 2BED BED RM - 1BED

HAC HAC

BATH RM BATH RM

BED RM - 2BED

BATH RM

BED RM - 2BED

BATH RM BED RM - ISOLATION

ANTE RM

BED RM - ISOLATIONBATH RM

BED RM - 2BED

BATH RM

CLEAN

UTILITY

STAIR HALL SOILED UTILITY

ALCOVE ALCOVE

BED RM - 2BED

BATH RM

MEDICATION RM

NURSE

STATION

NOURISHMENT

CONFERENCESTAFF

LOUNGE

STAIR HALL

BATH RM

BED RM - 2BED

SERVICE

ELEVATOR

PUBLIC

ELEVATOR

STAIR HALL

STAIR HALL

WOMEN TOILET

VESTIBULE

MEN

LOCKER

ENTRY

MENS

TOILET

PIPE CHASE

HAC

CONFERENCE

OFFICE

HAC HAC

OFFICE

STAIR

OFFICE

HOSPICE

PATIENT RM

UNISEX TOILET

HAC

CORRIDOR

EQUIP

STORAGE

HOSPICE

PATIENT ROOM

BED RM - 1BED

BATH RM

BED RM - 1BED

BED RM - 1BED

BATH RM

BED RM - 1BED BED RM - 1BED

BATH RM BED RM - 1BED

NURSE STATION

LOUNGE

MEDICATION RM

BED RM - 1BED

CORRIDOR

BATH RM

BED RM - 2BED

BATH RM

BED RM - 1BED BED RM - 1BED

BATH RM

BATH RM

BED RM - 1BED

STORAGE

BED RM - 1BED BATH RM

LAUNDRY

NURSE

OFFICE

CLEAN

STORAGE

CLEAN

UTILITY SOILED UTILITY

STAFF

TOILET

BREAK RM

VESTIBULE

STAFF

LOCKERS

OFFICE

BED RM - 1BED

BATH RM

BATH RM

BED RM - 2BED DAY ROOM

BED RM - 1BED BATH RM

SERVICE LOBBY

CLEAN

UTILITY

BED RM - 1BED

PUBLIC

ELEVATOR

ELEVATOR LOBBY

CORRIDOR

BED RM - 2BED

CHARTING

CHARTINGCHARTING

STAFF

TOILET

ELECTRICAL CLOSETELECTRICAL CLOSET

ELECTRICAL CLOSET

ELECTRICAL CLOSET

PATIENT TOILET

ELECTRICAL CLOSETELECTRICAL CLOSET

F.A.C

CABINET

ELECTRICAL

TR #400A

ADDITION

01-TN402

B15

01-TN402

B10

OUTLINE OF TR #539

AT FLOOR ABOVE

(1) 4"C - 24-STRAND, OS2,

OPTICAL FIBER CABLE

(1) 4"C - 24-STRAND, OS2,

OPTICAL FIBER CABLE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - 4TH FLOOR OVERALL

PLAN - TECHNOLOGY

01-TN205

-2

-7

-T

N

/2

/2

.p d f

N O R

HT

1/16" = 1'-0"

BUILDING 01 - 4TH FLOOR PLAN - TECHNOLOGY

A12

N

TRUE

NORTH

N

BUILDING

NORTH

KEY NOTES:

1. ROUTE CONDUITS UP TO CEILING HEIGHT.

PROVIDE PULL BOX AND PENETRATION THRU

CEILING TO ROUTE CONDUIT UP INTO TR #539 IN

NEW BUILDING ADDITION.

SITE KEY PLAN

N

TRUE NORTH

NOT TO SCALE

GENERAL NOTES:

1. ALL NEW CABLING SHALL BE INSTALLED IN

EXISTING CABLE TRAYS LOCATED IN

CORRIDORS OF FLOOR PLAN. PROVIDE J-HOOK

PATHWAYS FOR NEW CABLING FROM EXISTING

CABLE TRAY TO OUTLET LOCATIONS.

UP

UP

UP

DN.

UP DN.

UP

DN.

UP

DN

521C

521A

530 531 C5-10

533 560

C5-15

563 565

566A 567A

567 568

571 572 573A

C5-16

574A

576A

541A

540E 540D

540A540B

540F

577A

578A

580A

581A

C5-24

582A

585A

593593

500A

500C2-1 C5-14

C5-1

572X

517C 517D

518 519 520 521 522 523 525 526

517A 517

510511512513514515516 509

500C3-1

521B

517B

540C

C5-17 575

C5-18C5-19 C5-21

592A

504 591

C5-20

STAIR - 2

ELECTRICAL CLOSET

OFFICE

HEAD

NURSE

OFFICE

ELEVATOR LOBBY

SERVICE

ELEVATOR 3

PUBLIC

ELEVATOR

STAIR

UNISEX TOILET

IT CLOSET

MEDICATION RM

NOURISHMENT LOUNDRY

LOUNGE

BED RM - 2 BED

PATIENT

SHOWER

PATIENT

SHOWER

BED RM - 2 BED STAIR

STORAGE

SOILED UTILITY CLEAN UTILITY

PATIENT

SHOWER

BED RM - 2 BED

ALCOVE

PATIENT

SHOWER

BED RM - ISOLATION

PATIENT

SHOWER

BED RM - ISOLATION

HAC

PIPE CHASE

PATIENT TOILET

MENS LOCKER

STAIR

MECH

ENTRY PASSAGE

CLOSET

STAFF LOCKERS

OFFICE

OFFICE

STORAGE

BED RM - 2 BED

PATIENT

SHOWER

BED RM - 2 BEDPATIENT

SHOWER

EQUIP

STORAGEPATIENT

SHOWER

BATH RM

PATIENT TOILET

ALCOVE

BED RM - 1 BED

PATIENT

SHOWER

BED RM - 1 BED

BED RM - 2 BED

BATH RM

PATIENT

SHOWER

BED RM - 2 BED

PHYSICIAN OFFICE

PHYSICIAN OFFICE

PHYSICIAN OFFICE

PHYSICIAN OFFICE

HAC

BREAK RMBREAK RM

DINING

STORAGE

PATIENT TOILET

WAITING

HAC

OFFICE

BED RM - 2 BED

CORRIDOR

CORRIDOR

ELEVATOR LOBBY

CORRIDOR

OFFICE OFFICE

OFFICE OFFICE OFFICE

OFFICE OFFICE OFFICE OFFICE OFFICE

OFFICE

OFFICE OFFICE

OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICE OFFICE

STAFF TOILET

KITCHENETTE

OFFICE

HAC

CORRIDOR

MECH

ELECTRICAL CLOSET

STORAGE

PATIENT TOILET

TELEPHONE CLOSET

CHARTING KITCHEN

CHARTINGALCOVE

HAC

HAC

UNISEX TOILET UNISEX TOILET

STORAGE

NEW TR

TR #539

ADDITION

01-TN403

G15

01-TN403

G10

(1) 4"C - 24-STRAND, OS2,

OPTICAL FIBER CABLE

(1) 4"C - 24-STRAND, OS2,

OPTICAL FIBER CABLE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - 5TH FLOOR OVERALL

PLAN - TECHNOLOGY

01-TN206

-2

-7

-T

N

/2

/2

.p d f

N O R

HT

1/16" = 1'-0"

BUILDING 01 - 5TH FLOOR PLAN - TECHNOLOGY

A12

N

TRUE

NORTH

N

BUILDING

NORTH

KEY NOTES:

1. ROUTE CONDUITS UP TO CEILING HEIGHT.

PROVIDE PULL BOX AND PENETRATION THRU

CEILING TO ROUTE CONDUIT UP INTO TR #539 IN

NEW BUILDING ADDITION.

SITE KEY PLAN

N

TRUE NORTH

NOT TO SCALE

GENERAL NOTES:

1. ALL NEW CABLING SHALL BE INSTALLED IN

EXISTING CABLE TRAYS LOCATED IN

CORRIDORS OF FLOOR PLAN. PROVIDE J-HOOK

PATHWAYS FOR NEW CABLING FROM EXISTING

CABLE TRAY TO OUTLET LOCATIONS.

CHASE

CHASE

CHASE

CHASECHASE

ATTIC

CORRIDOR

CORRIDOR

CORRIDOR

ATTIC

STAIR

LOBBY

STORAGE

MECHSTAIR

STORAGE STORAGE

MEDICATION RM CHIEF OF

SURGICAL

HAC

ELEVATOR

SERVICE

ELEVATOR

STAIR

BATH RM

FEC

FOYER

BED RM -

ISOLATION HAC

CONFERENCE

COMPUTER RM

RESIDENT

ON-CALL BED

KITCHEN

SINK

OFFICE

ELECTRICAL

CLOSET

OFFICE

OFFICE

STAFF

TOILET

OFFICE

COMPUTER

RM

HAC

HAC

603A 617

610A

610 611A

611B

611C

611D

611E

601D

601A

601B

616A

UP DN

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - 6TH FLOOR OVERALL

PLAN - TECHNOLOGY

01-TN207

-2

-7

-T

N

/2

/2

.p d f

N O R

HT

1/16" = 1'-0"

BUILDING 01 - 6TH FLOOR PLAN - TECHNOLOGY

A12

N

TRUE

NORTH

N

BUILDING

NORTH

GENERAL NOTES:

1. SIXTH FLOOR NETWORK DEVICES SHALL BE FED

FROM FIFTH FLOOR TR #539.

SITE KEY PLAN

N

TRUE NORTH

NOT TO SCALE

CHASE

CHASE

CHASE

CHASECHASE

ATTIC

CORRIDOR

CORRIDOR

CORRIDOR

ATTIC

LOBBY

STORAGE

STORAGE STORAGE

MEDICATION RM CHIEF OF

SURGICAL

HAC

ELEVATOR

SERVICE

ELEVATOR

STAIR

BATH RM

FEC

FOYER

BED RM -

ISOLATION HAC

CONFERENCE

COMPUTER RM

RESIDENT

ON-CALL BED

KITCHEN

SINK

OFFICE

ELECTRICAL

CLOSET

OFFICE

OFFICE

STAFF

TOILET

OFFICE

COMPUTER

RM

HAC

HAC

603A 617

610A

610 611A

611B

611C

611D

611E

601D

601A

601B

616A

UP DN

2D

2D

D

2D

D

D

D

D

D

D

1D

1D-WAP

1D-WAP

2D

D

D

D

D

/T V

6D2D 6D

D

2D 2D

2D

D

2D

2D 2D

2D

01-TN207C

01-TN207B

01-TN207C

01-TN207D01-TN207C01-TN207A

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - 6TH FLOOR PLAN -

AREA C - TECHNOLOGY

01-TN207C

-2

-7

-T

N C

/2

/2

.p d f

N O R

HT

1/8" = 1'-0"

BUILDING 01 - 6TH FLOOR PLAN - AREA C - TECHNOLOGY

A11

N

TRUE

NORTH

N

BUILDING

NORTH

KEYNOTE :

1. ROUTE NEW CABLING FOR SIXTH FLOOR

NETWORK DEVICES DOWN THRU CHASE TO

ABOVE FIFTH FLOOR CEILING AND OVER TO TR #

539. PROVIDE PENETRATIONS THRU FLOOR AND

FIRE RATED PATHWAYS AS REQUIRED.

SITE KEY PLAN

N

TRUE NORTH

NOT TO SCALE

GENERAL NOTES:

1. REFER TO 00-TN000 TELECOMMUNICATIONS

SYMBOLS AND ABBREVIATIONS FOR TECHNOLOGY

NOTES, TECHNOLOGY INSTALLATION NOTES AND

SYMBOLS LIST NEW CABLING.

2. ALL INFORMATION OUTLETS ON THIS SHEET SHALL

BE SERVED FROM TELECOM ROOM TR #572A IN

BLDG #1 UNLESS OTHERWISE NOTED. REFER TO

00-TN000 FOR EXACT LOCATION.

3. REFER TO 00-TN602 FOR TELECOMMUNICATIONS

EQUIPMENT SCHEDULE.

4. CONTRACTOR SHALL INCLUDE AN ALLOWANCE

FOR 10 ADDITIONAL 2-PORT CAT6A OUTLETS IN

THEIR PROPOSAL FOR THIS SHEET. FUTURE

OUTLET LOCATIONS WILL BE DETERMINED BY VA

AT LATER DATE.

5. CONTRACTOR TO FIELD VERIFY CONDUIT RISER

ROUTE WITH OWNER PRIOR TO INSTALLATION.

6. CONTRACTOR TO PROVIDE NEW J-HOOKS ROUTES

FOR ALL NEW CABLING, J-HOOK SIZE AND

QUANTITY TO BE PER MANUFACTURER'S

RECOMMENDATIONS.

7. ALL INFORMATION OUTLETS ON THIS SHEET TO BE

CABLED ON A SCHEDULED BASIS WITH OWNER

WHILE OCCUPPIED WITH STAFF AND PATIENTS.

COORDINATE DEMO AND CABLE REPLACEMENT

WITH OWNER.

8. CONTRACTOR TO PROVIDE 1" OR 2" SLEEVE WITH

FIRE-STOPPING INTO EACH ROOM WITH NEW

CABLING.

C C

T V

M

CSS

MICROBIOLOGY

6A

CSS

C C

T V

M

WORK RM

NEW TR

6B

01-TN400

G5

SC-TTB

SC-PBB-1

(TYP.)

AC-SCP-1

R3 R2 R1

6B

/1

3'-9"

5'-10 1/4"

12"x4"

12"x4"

12"x4"

SC-CT-1

"x

"x

(TYP.)

PW-CPW-1

(TYP.)

(4) 4" CONDUIT SLEEVES

NOTES:

1. INSTALL CABLE TRAY AT 7'-6"AFF.

2. REFER TO 00-TN602 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

SC-ER-1

(TYP.)

SC-BLK-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

VA NETWORK SW.

SC-HWM-2

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-UPS-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-UPS-1

SC-BLK-1

SC-BLK-1SC-BLK-1

R1 R2

SC-PDU-2

(TYP.)

SC-VWM-1

(TYP.)

NOTES:

1. REFER TO 00-TN602 FOR TECHNOLOGY EQUIPMENT

SCHEDULE.

2. INSTALL RACK BONDING BUSBAR AT TOP RMU ON BACK

SIDE OF EQUIPMENT RACK. REFER TO 17/00-TN504 FOR

ADDITIONAL INFORMATION.

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

NEW TR

27A 01-TN400

B5

SC-TTB

SC-SBB-1

(TYP.)

AC-SCP-1

R1R2

27A

/8

11'-11 1/2"

/1

6'-3 3/4" 2'-1 3/4"

12"x4"

12"x4"

12"x4"

"x

"x

SC-CT-1

(TYP.)

PW-CPW-1

(TYP.)

(4) 4" CONDUIT SLEEVES

NOTES:

1. INSTALL CABLE TRAY AT 7'-6"AFF.

2. REFER TO 00-TN602 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

SC-BLK-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

SC-HWM-2

VA NETWORK SW.

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-UPS-1SC-UPS-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

VA NETWORK SW.

SC-HWM-2

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-MPP-2

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

R1 R2

SC-ER-1

(TYP.)

NOTES:

1. REFER TO 00-TN602 FOR TECHNOLOGY EQUIPMENT

SCHEDULE.

2. INSTALL RACK BONDING BUSBAR AT TOP RMU ON BACK

SIDE OF EQUIPMENT RACK. REFER TO 17/00-TN504 FOR

ADDITIONAL INFORMATION.

SC-VWM-1

(TYP.)

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

Revisions: Date:

CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

Lebanon VA Medical Center 1700 S Lincoln Ave.

Lebanon, PA 17042

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

ARCHITECT / ENGINEER OF RECORD:

CONSULTANT:

DAVID MCCOY

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

412 KING ST

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

CONSULTANT:

LENNY HENDRIX

101 NORTH SEVENTH STREET

LOUISVILLE, KY 40202

440-262-3063

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

MICHAEL SMITH

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/07/2025

595-22-700

ECWACA

EHRM INFRASTRUCTURE UPGRADES

LEBANON, PA.

100% BID DOCUMENT SUBMISSION

BUILDING 01 - TECHNOLOGY

ENLARGED PLANS

01-TN400

-2

-7

-T

N

/2

/2

.p d f

1/4" = 1'-0"

EQUIPMENT ENLARGEMENT ROOM TR-#6A

G15

1/4" = 1'-0"

PATHWAY ENLARGEMENT ROOM TR-#6A

G10 1" = 1'-0"

RACK ELEVATION TR-#6A

G5

1/4" = 1'-0"

EQUIPMENT ENLARGEMENT ROOM TR-#27A

B15 1/4" = 1'-0"

PATHWAY ENLARGEMENT ROOM TR-#27A

B10 1" = 1'-0"

RACK ELEVATION TR-#27A

B5

N

BUILDING

NORTH

NOTES:

1. REFER TO PATHWAY ENLARGEMENT PLANS FOR CABLE TRAY LAYOUT.

2. REFER TO 00-TN602 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

3. REFER TO ELECTRICAL DRAWING FOR ELECTRICAL PANEL BONDING LOCATION.

KEYNOTES:

1. PROVIDE CAT6A CABLE FROM NEW EQUIPMENT RACK TO EACH EXISTING ACCESS CONTROL PANEL THAT SERVES THIS FLOOR. COORDINATE EXACT LOCATION OF ACCESS CONTROL PANELS WITH SIEMENS.

2. RELOCATE EXISTING VIDEO SURVEILLANCE NETWORK SWITCHES TO NEW EQUIPMENT RACKS IN NEW OR RE-USED TELECOM ROOMS. COORDINATE EXACT LOCATION AND QUANTITY OF NETWORK SWITCHES

WITH SIEMENS.

3. PROVIDE NEW 6-STRAND, OM4, OPTICAL FIBER CABLE IN INNERDUCT FROM FIBER DISTRIBUTION IN NEW TELECOM RACK TO EXISTING TELECOM ROOM. TERMINATE FIBER WITH LC CONNECTORS AT BOTH ENDS.

COORDINATE EXACT TERMINATION LOCATION IN EXISTING TELECOM ROOM WITH SIEMENS.

4. VERIFY EXISTING CAMERA QUANTITIES/LOCATIONS WITH SIEMENS AND PROVIDE NEW CAT6A CABLES TO

MATCH QUANTITIES. CONNECT CAMERA'S NEW CABLES TO SAME PATCH PANELS.

NOTES:

1. REFER TO PATHWAY ENLARGEMENT PLANS FOR CABLE TRAY LAYOUT.

2. REFER TO 00-TN602 FOR TECHNOLOGY EQUIPMENT SCHEDULE.

3. REFER TO…