Attachment 3 - Drawings 589-501 16-50.pdf

PDF 15 MB Posted

Attached to
589-501 Construction Outpatient Mental Health Addition (VA-24-00072549)
Solicitation number
36C77624B0031
Issued by

About this file

This document appears to be Attachment 3 - Drawings 589-501 16-50.pdf, which contains drawings related to the federal contract opportunity for the 589-501 Construction Outpatient Mental Health Addition (VA-24-00072549) solicitation.

The solicitation, with Solicitation Number 36C77624B0031, is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin for the construction of an outpatient mental health addition. The solicitation requires the contractor to provide all labor, materials, equipment, and supervision necessary to complete the construction project as depicted in the attached drawings. No additional details about the specific products, services, or performance requirements are provided in this document.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

AD102

B

AD102

B

AD102

B

AD102

C

TEMPORARY CONSTRUCTION PARTITION

TEMPORARY

CONSTRUCTION

PARTITION

TEMPORARY

CONSTRUCTION

PARTITION

TEMPORARY

CONSTRUCTION PARTITION

NO ARCHITECTURAL DEMOLITION IN BASEMENT. SEE

OTHER DISCIPINE SHEETS FOR DEMOLITION WORK.

GROUP ROOM

A005

OFFICE

A004

OFFICE

A006

OFFICE

A007

PT RM

A009

PT RM

A011

PT RM

A012

PT RM

A008

WORKROOM

A003

OFFICE

A002

ELECTRICAL

A027

ELECTRICAL

A026

HALL

A8A

HALL

A013

STAIR 1

0A-S1

ENERGY

MANAGEMENT

A013C

STORAGE

A013A

MECH

A013B

ENG

A013

ELEC

A015

HALL

A015A

NEUROPSYCH

A018

NEUROPSYCH

A017

NEUROPSYCH

A016

ELEVATOR #6

A0-E6

ELEVATOR #5

A0-E8

ELEVATOR #4

A0-E4

STORAGE

A023

HOUSEKEEPING

A022 MEN

A021

WOMEN

A020

STAIR

0A-S4

LOCKER

A019

FIRE CLOSET

A025

CORRIDOR

0CDR1

STOR

A029

MECH

A015B

NO ARCHITECTURAL

DEMOLITION IN CRAWL SPACE

NO ARCHITECTURAL

DEMOLITION IN CRAWL SPACE

ENTRY

A100

LOBBY

A101

WOMEN

A101B

RR

A101H

OFFICE

A101A

BHC

MEDICATION

ROOM

A169

RR

A168A

STORAGE

A169A

CONFERENCE

A168

ELEVATOR #4

A1-E4

ELEVATOR #5

A1-E5

TELE ALCOVE

A101D

TELE ALCOVE

A101C

CHASE

A169P

MELLEN CONF

ROOM

C167

ELECTRICAL

C167E

PSYCH OFFICE

C166

CONF ROOM

C165

TESTING ROOM

C165A

CONF ROOM

C164B

TESTING ROOM

C164A

STAFF OFFICE

C164

CORRIDOR

1CDR11

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

DEMOLITION GENERAL NOTES

A. VERIFY ALL CONDITIONS PRIOR TO DEMOLITION. DISCREPANCIES BETWEEN DESIGN CONDITIONS

AND EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.

B. DEMOLITION SHALL BE DONE IN A MANNER TO REDUCE THE AMOUNT OF DAMAGE TO ADJACENT

MATERIALS AND CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING

AND REPAIR OF ADJACENT MATERIALS DUE TO DEMOLITION TO THE SATISFACTION OF THE

CONTRACTING OFFICER REPRESENTATIVE.

C. DEMOLITION SCOPE TO INCLUDE THE REMOVAL OF ALL EXISTING ELEMENTS AS REQUIRED TO

COMPLETE SCOPE OF WORK/CONSTRUCTION INCLUDED IN THESE DOCUMENTS, WHETHER OR

NOT SPECIFICALLY INDICATED HEREIN.

D. ALL WALLS, STRUCTURAL FRAMES, PARTITIONS, EQUIPMENT, ETC. INDICATED BY DASHED LINES

SHALL BE REMOVED. ALL WALLS, STRUCTURAL FRAMES, PARTITIONS, EQUIPMENT, ETC.

INDICATED BY SOLID LINES TO REMAIN.

E. PROVIDE TEMPORARY DUST-PROOF PARTITIONS REQUIRED TO SEAL DUST GENERATED DURING

CONSTRUCTION ACTIVITIES FROM ENTERING OCCUPIED PORTIONS OF THE BUILDING. MAKE

TEMPORARY PROVISIONS AS NECESSARY TO ACCOMMODATE MAKEUP AND RETURN AIR

AFFECTED BY TEMPORARY DUST PROOFING. TEMPORARY PARTITIONS TO BE RATED AS

REQUIRED ON LIFE SAFETY DRAWINGS. PROVIDE CONSTRUCTION SAFETY SIGNAGE AT ALL

ENTRANCES TO CONSTRUCTION AREAS, SEE SIGNAGE DRAWINGS FOR ADDITIONAL

INFORMATION.

F. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF HVAC AND ELECTRICAL ITEMS TO

BE REMOVED.

G. STRUCTURAL COLUMNS, BEAMS, JOISTS, BEARING WALLS AND OTHER STRUCTURAL LOAD

BEARING MEMBERS TO REMAIN INTACT, U.N.O.

H. COORDINATE WITH THE OWNER REMOVAL AND STORAGE OF ALL EXISTING EQUIPMENT TO BE

RELOCATED.

I. DEMOLITION NOTES INDICATED ON DRAWINGS MAY NOT BE ALL INCLUSIVE. REMOVE ALL ITEMS

REQUIRED FOR RECONSTRUCTION AND TO ACCOMMODATE NEW WORK.

J. VERIFY EXTENT OF ALL CONDITIONS OF DEMOLITION WITH FLOOR PLAN AND SCHEDULED

CONSTRUCTION PRIOR TO DEMOLITION. DISCREPANCIES BETWEEN DESIGN CONDITIONS AND

EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE C.O.R.

K. AFTER REMOVAL OF EXISTING FLOOR FINISH, CONCRETE SLAB SHALL BE PATCHED, GROUND SMOOTH, AND LEVELED BEFORE INSTALLATION OF NEW FINISH PER ROOM FINISH SCHEDULE. AT

DISSIMILAR FLOOR ELEVATIONS, FEATHER SELF-LEVELING UNDERLAYMENT COMPOUND TO EACH

FLOOR ELEVATION AND GRIND SMOOTH.

L. PATCH TO MATCH ADJACENT SURFACES OF EXISTING WALLS AND FLOORS IN ALL AREAS

REQUIRED DUE TO THE REMOVAL OF MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT OR

FIXTURES.

M. WHERE EXISTING WALLS OR CEILINGS ARE DISTURBED FOR ACCESS TO SERVICES, PATCH TO MATCH DISTURBED MATERIALS AND FINISHES TO ORIGINAL CONDITION. WHERE REPAINTING IS

REQUIRED, THE ENTIRE WALL OR CEILING SURFACE SHALL BE PAINTED TO THE NEAREST

CORNERS.

N. CEILINGS WHICH ARE IN CONFLICT WITH NEW WORK SHALL BE REMOVED OR RELOCATED ALONG

WITH ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS.

O. ALL EXISTING UNUSED WALL PENETRATIONS IN INTERIOR AND EXTERIOR WALLS ALONG WITH PENETRATIONS LEFT AFTER SELECTIVE DEMOLITION ACTIVITIES SHALL BE INFILLED TO MATCH

ADJACENT WALL FINISHES, THICKNESS, AND SMOKE/FIRE RATING AS REQUIRED.

P. MAINTAIN CLEAR EXIT PATHS DURING DEMOLITION AND CONSTRUCTION ACTIVITIES.

NOTE:

REFERENCE THE PHASING PLANS FOR ADDITIONAL INFORMATION FOR PROJECT PHASING AND

COORDINATION OF DEMOLITION AND NEW CONSTRUCTION FOR THE PROJECT.

LINETYPE LEGEND

LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN

HEAVY DASHED LINE INDICATES EXISTING ELEMENT TO BE

REMOVED IN ITS ENTIRETY U.O.N.

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:2

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

AD101

OVERALL DEMOLITION PLAN Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 16' 32'8'1/16" = 1'-0"B

DEMOLITION PLAN - FIRST FLOOR - OVERALL

0 16' 32'8'1/16" = 1'-0"A

DEMOLITION PLAN - BASEMENT - OVERALL

N N

Revisions: Date:

8 11

24 24 24 24 24

2 2

11 13

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

DEMOLITION GENERAL NOTES

A. VERIFY ALL CONDITIONS PRIOR TO DEMOLITION. DISCREPANCIES BETWEEN DESIGN CONDITIONS

AND EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.

B. DEMOLITION SHALL BE DONE IN A MANNER TO REDUCE THE AMOUNT OF DAMAGE TO ADJACENT

MATERIALS AND CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING

AND REPAIR OF ADJACENT MATERIALS DUE TO DEMOLITION TO THE SATISFACTION OF THE

CONTRACTING OFFICER REPRESENTATIVE.

C. DEMOLITION SCOPE TO INCLUDE THE REMOVAL OF ALL EXISTING ELEMENTS AS REQUIRED TO

COMPLETE SCOPE OF WORK/CONSTRUCTION INCLUDED IN THESE DOCUMENTS, WHETHER OR

NOT SPECIFICALLY INDICATED HEREIN.

D. ALL WALLS, STRUCTURAL FRAMES, PARTITIONS, EQUIPMENT, ETC. INDICATED BY DASHED LINES

SHALL BE REMOVED. ALL WALLS, STRUCTURAL FRAMES, PARTITIONS, EQUIPMENT, ETC.

INDICATED BY SOLID LINES TO REMAIN.

E. PROVIDE TEMPORARY DUST-PROOF PARTITIONS REQUIRED TO SEAL DUST GENERATED DURING

CONSTRUCTION ACTIVITIES FROM ENTERING OCCUPIED PORTIONS OF THE BUILDING. MAKE

TEMPORARY PROVISIONS AS NECESSARY TO ACCOMMODATE MAKEUP AND RETURN AIR

AFFECTED BY TEMPORARY DUST PROOFING. TEMPORARY PARTITIONS TO BE RATED AS

REQUIRED ON LIFE SAFETY DRAWINGS. PROVIDE CONSTRUCTION SAFETY SIGNAGE AT ALL

ENTRANCES TO CONSTRUCTION AREAS, SEE SIGNAGE DRAWINGS FOR ADDITIONAL

INFORMATION.

F. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF HVAC AND ELECTRICAL ITEMS TO

BE REMOVED.

G. STRUCTURAL COLUMNS, BEAMS, JOISTS, BEARING WALLS AND OTHER STRUCTURAL LOAD

BEARING MEMBERS TO REMAIN INTACT, U.N.O.

H. COORDINATE WITH THE OWNER REMOVAL AND STORAGE OF ALL EXISTING EQUIPMENT TO BE

RELOCATED.

I. DEMOLITION NOTES INDICATED ON DRAWINGS MAY NOT BE ALL INCLUSIVE. REMOVE ALL ITEMS

REQUIRED FOR RECONSTRUCTION AND TO ACCOMMODATE NEW WORK.

J. VERIFY EXTENT OF ALL CONDITIONS OF DEMOLITION WITH FLOOR PLAN AND SCHEDULED

CONSTRUCTION PRIOR TO DEMOLITION. DISCREPANCIES BETWEEN DESIGN CONDITIONS AND

EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE C.O.R.

K. AFTER REMOVAL OF EXISTING FLOOR FINISH, CONCRETE SLAB SHALL BE PATCHED, GROUND SMOOTH, AND LEVELED BEFORE INSTALLATION OF NEW FINISH PER ROOM FINISH SCHEDULE. AT

DISSIMILAR FLOOR ELEVATIONS, FEATHER SELF-LEVELING UNDERLAYMENT COMPOUND TO EACH

FLOOR ELEVATION AND GRIND SMOOTH.

L. PATCH TO MATCH ADJACENT SURFACES OF EXISTING WALLS AND FLOORS IN ALL AREAS

REQUIRED DUE TO THE REMOVAL OF MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT OR

FIXTURES.

M. WHERE EXISTING WALLS OR CEILINGS ARE DISTURBED FOR ACCESS TO SERVICES, PATCH TO MATCH DISTURBED MATERIALS AND FINISHES TO ORIGINAL CONDITION. WHERE REPAINTING IS

REQUIRED, THE ENTIRE WALL OR CEILING SURFACE SHALL BE PAINTED TO THE NEAREST

CORNERS.

N. CEILINGS WHICH ARE IN CONFLICT WITH NEW WORK SHALL BE REMOVED OR RELOCATED ALONG

WITH ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS.

O. ALL EXISTING UNUSED WALL PENETRATIONS IN INTERIOR AND EXTERIOR WALLS ALONG WITH PENETRATIONS LEFT AFTER SELECTIVE DEMOLITION ACTIVITIES SHALL BE INFILLED TO MATCH

ADJACENT WALL FINISHES, THICKNESS, AND SMOKE/FIRE RATING AS REQUIRED.

P. MAINTAIN CLEAR EXIT PATHS DURING DEMOLITION AND CONSTRUCTION ACTIVITIES.

NOTE:

REFERENCE THE PHASING PLANS FOR ADDITIONAL INFORMATION FOR PROJECT PHASING AND

COORDINATION OF DEMOLITION AND NEW CONSTRUCTION FOR THE PROJECT.

LINETYPE LEGEND

LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN

HEAVY DASHED LINE INDICATES EXISTING ELEMENT TO BE

REMOVED IN ITS ENTIRETY U.O.N.

SHEET KEYNOTES (NOT ALL NOTES APPLY TO PLAN)

WORK AT TEMPORARY MAIN ENTRANCE TO BE

COMPLETED PRIOR TO MAIN ENTRANCE

CLOSURE.

REMOVE METAL RAMP.

REF. CIVIL

REMOVE STEEL EDGING.

REMOVE STAIR TREADS

AND NOSINGS.

REF. CIVIL

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:2

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

AD102

DEMOLITION PLAN - FIRST FLOOR Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"A

DEMOLITION PLAN - FIRST FLOOR

N

2 TEMPORARY CONSTRUCTION SEPARATION PARTITION

3 REMOVE EXISTING STOREFRONT PARTITION IN ITS ENTIRETY.

4 REMOVE EXISTING FURNITURE PARTITION IN ITS ENTIRETY.

7 REMOVE EXISTING ACOUSTICAL WALLCOVERING.

8 REMOVE EXISTING FLOORING TO SLAB. PATCH, LEVEL/PREPARE FOR NEW FINISH.

9 REMOVE EXISTING CARPETING OVER TERRAZO FLOORING. PATCH AND REPAIR TERRAZO FLOORING AS

REQUIRED.

10 EXISTING TERRAZO FLOORING TO REMAIN. PROTECT DURING CONSTRUCTION ACTIVITIES AND REPAIR AS

REQUIRED.

11 REMOVE EXISTING ACOUSTICAL CEILING TILE SYSTEM.

13 REMOVE ALL EXISTING TOILET ACCESSORIES.

16 REMOVE EXISTING MARKERBOARD.

17 REMOVE EXISTING DISPLAY CABINET.

18 REMOVE EXISTING PLUMBING FIXTURE (SINK, FLOOR, DRAIN, WATER CLOSET, URINAL, DRINKING

FOUNTAIN AND/OR LAVATORY), RE: MEP.

20 REMOVE EXISTING DOOR. EXISTING FRAME AND THRESHOLD TO REMAIN. SEE IMPROVEMENT PLAN AND

DOOR SCHEDULE FOR NEW DOOR TYPE.

21 REMOVE PORTION OF EXISTING MASONRY WALL FOR NEW OPENING.

22 REMOVE EXISTING EXTERIOR WINDOW IN ITS ENTIRETY. REMOVE MASONRY BELOW AS REQUIRED FOR

NEW OPENING. PREPARE SURFACE FOR NEW WORK.

23 REMOVE EXISTING EXTERIOR WINDOW IN ITS ENTIRETY.

24 REMOVE EXISTING DOOR, FRAME, AND THRESHOLD IN THEIR ENTIRETY.

27 REMOVE EXISTING WOOD WALL TRIM AND PATCH WALL TO RECEIVE NEW FINSIHES.

28 REMOVE PORTION OF EXISTING CONCRETE CANOPY TO ACCOMODATE NEW BUILDING. SEE DETAIL 4/A-501.

29 REMOVE EXISTING ROOF SYSTEM DOWN TO DECK. SEE IMPROVEMENT PLAN FOR MORE INFORMATION.

30 TEMPORARY CONSTRUCTION SEPARATION PARTITION

0 4' 8'2'1/4" = 1'-0"B

DEMOLITION PLAN - FIRST FLOOR @ STAIRS - SIM

C

DEMOLITION PLAN - FIRST FLOOR @ RAMP

DN

DN

DN

NEUROPSYCH

A016

NEUROPSYCH

A017 IT

A018

P. TLT.

A019

S. TLT.

A020

STAIR

A0-S1

STOR

A002

WKRM

A003

OFFICE

A004

GROUP ROOM

A005

OFFICE

A006

OFFICE

A007

PT RM

A009

PT RM

A008

PT RM

A011

PT RM

A012

ELEC

A027

ELEC

A026

HALL

A030

FILE STORAGE

A013A

MECH (N.I.C.)

A013B

ENERGY MGMT

(N.I.C.)

A013C

HALL

(N.I.C)

A013

MECH (N.I.C.)

A014

HALL (N.I.C.)

A015A

ELEC (N.I.C.)

A015

STAIR

A0-S4

CORRIDOR

0CDR1

STOR (N.I.C.)

A023

HSK N.I.C.

A022

FE

A025

HALL

A028

STOR

A029

ELEV #4

A0-E4

ELEV #5

A0-E5

ELEV #6

A0-E6

STAIR

B0-S2

STAIR

C0-S3

UNEXCAVATED

NO ARCHITECTURAL

IMPROVEMENT IN CRAWL SPACE

NO ARCHITECTURAL

IMPROVEMENT IN CRAWL SPACE

NOTE: NO ARCHITECTURAL IMPROVEMENT IN BASEMENT.

SEE MECHANICAL DEMOLITION DRAWINGS FOR ABOVE

CEILING WORK.

P. TLT.

A128

P. TLT.

A129

SUD GROUP

THERAPY

C136

SUD OFFICE

C134

SUD OFFICE

C133

S. TLT.

C131

S. TLT.

C130

P. TLT.

C126

P. TLT.

C125

STOR.

C127

CAROTAS

C128

STAFF LOUNGE

C129

A-201

B

MSA

A103

LOBBY

A101

CHILDREN'S

WAITING

A104

P. TLT.

A105

ALCOVE

A106

VESTIBULE

A100

DRINKING

FOUNTAIN

A130

STOR.

C132

ELEC

C135

VESTIBULE

A102

HALL

A131

HOLD

D101

CONSULT

D102

BHIP OFFICE

D103

BHIP OFFICE

D104

BHIP OFFICE

D105

BHIP OFFICE

D106

IT

D107

CWT OFFICE

D108

VESTIBULE

D109

P. TLT.

D110

P. TLT.

D111

BHIP OFFICE

D112

STAFF WORK

D113

CONF / CLASS

D114

BHIP OFFICE

D115

BHIP OFFICE

D116

BHIP OFFICE

D117

BHIP OFFICE

D118

BHIP OFFICE

D119

BHIP OFFICE

D120

BHIP OFFICE

D121

BHIP OFFICE

D122

BHIP OFFICE

D123

BHIP OFFICE

D124

BHIP OFFICE

D125

BHIP OFFICE

D126

BHIP OFFICE

D127

BHIP OFFICE

D128

BHIP OFFICE

D129

BHIP OFFICE

D130

CONF

D131

BHIP OFFICE

D132

BHIP OFFICE

D133

BHIP OFFICE

D134

COURTYARD

D135

A-201

C

A-201

E A-201

F

A-201

D

CORRIDOR

1CDR7

CORRIDOR

1CDR10

CORRIDOR

1CDR11

HALL

D136

TO CONNECTING

CORRIDOR

ELEC

D137

21 22.7 25.4 32.5 33.3 33.8

L.5

M

P

P.5

29.1

O.5

N.5

N

O

27 30.928.522.2

L

J.8

J

L (E)

K.8

A-301

A-301

A-301

A-301

A-301

HSK

D138

M.9

L.9

M.3

A-201

G

21.1

A-401

A-401

A-401

A-401

A-201

G

Sim

A-201

G

Sim

6' - 0"

STAFF NURSE

A224

SOCIAL

WORKER

A225

SOCIAL

WORKER

A226

STAFF NURSE

A227

WORK RM

A228

HALL

A229

WOMEN

A230MEN

A231

RR

A232

STAFF NURSE

A233

SOCIAL

WORKER

A234

STAFF NURSE

A235

STAFF PSYCH

A236

STAFF PSYCH

A237

STAFF NURSE

A238

SOCIAL

WORKER

A239

CLINICAL PSYCH

A240

STAIR 2

A241

STAFF SOCIAL

WORKER

A243

STAFF NURSE

A244

STAFF PSYCH

OFFICE

A245

STAFF PSYCH

OFFICE

A246

PSYCH NURSE

PRACTITIONER

A247

STAFF PSYCH

A248

STAFF NURSE

A249

NURSE

PRACTITIONER

A250

LOUNGE

A251

SOCIAL

WORKER

A252

PSYCH NURSE

PRACT

A253

PSYCHIATRY

RES.

A254

WAITING AREA

A255

STAFF PSYCH

A256

STAFF PSYCH

A257

NURSE

PRACTITIONER

A258

NURSE

PRACTITIONER

A259

CORRIDOR

A260

CORRIDOR

A261

CHASE

A262

ELECTRICAL

A263

ELECTRICAL

A264

HOUSEKEEPING

A265

SUPPLY ROOM

A266

RR

A267

RECEPTION

A268

IT CLOSET

A269

MEN

A270

STAIR 1

A272

CORRIDOR

A273

CORRIDOR

A274

CORRIDOR

A275 ELEVATOR #6

A276

ELECTRICAL

A277

ELECTRICAL

A278

EMS STORAGE

(N.I.C.)

A279

FIRE CLOSET

A280

OFFICE

A281

OFFICE

A282

MEN

A283

LOUNGE

A284

STAFF ONLY RR

A285

UNIVERSAL

WASTE

A286

CCTV CONTROL

ROOM

A287

PHOTO STUDIO

/PRINT

A288

MEDICAL MEDIA

A289

OFFICE

A290

STAFF

PSYCHOLOGIST

A291

STAFF

PSYCHOLOGIST

A292

ENGINEERING

(N.I.C.)

A293

LOADING DOCK

A294

STAFF

RESTROOM

A295

MEN

A296

SECRETARY

OFFICE

A297

SERVICE LINE

MANAGER

A299

NURSE

MANAGER

A300

BEHAVIORAL

HEALTH

SERVICE

A301

ASSO.

MANAGER

A302

MANAGEMENT

ANALYST

A303

CLINICAL

OPERATIONS

SUPPORT

A304WORK ROOM

A305

FIRE CLOSET

A306

CORRIDOR

A307

STAIR

A309

PSYCH SUPPLY

A310

HOUSEKEEPING

A311

WOMEN

A312

ELECTRICAL

A313

BEHAVIORAL

HEALTH STAFF

A314

PHARMACIST

A315

PHARMACIST

A316

SUPERVISOR

A317

ADDICTION

THERAPIST

A318

NURSE

MANAGER

A319

SUICIDE

PREVENTION

CASE MANAGER

A320

SUICIDE

PREVENTION

COORDINATOR

A321

LOCAL

RECOVERY

COORDINATOR

A322

CLINICAL PSYCH

A323

STAFF PSYCH

A324

CORRIDOR

A325

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

FLOOR PLAN GENERAL NOTES

A. ALL INFECTION CONTROL CRITERIA AS SPECIFIED IN SECTION 01 35 26 SHALL BE ADHERED TO

DURING ALL PHASES OF THE PROJECT.

B. CONTRACTOR SHALL ERECT AND MAINTAIN A RATED SEPARATION DURING ALL CONSTRUCTION

PHASES, AS REQUIRED ON THE LIFE SAFETY DRAWINGS.

C. CONTRACTOR SHALL FIELD-LOCATE THE TEMPORARY WALLS AND DOORS AND COORDINATE

LOCATION WITH THE C.O.R. PROVIDE CONSTRUCTION SAFETY SIGNAGE AT ALL ENTRANCES TO

CONSTRUCTION AREAS, SEE SIGNAGE DRAWINGS FOR ADDITIONAL INFORMATION.

D. RENOVATION WORK SHALL BE COMPLETED WITH MINIMAL DISRUPTION TO BUILDING

OPERATIONS. THE OWNER RESERVES THE RIGHT TO TEMPORARILY STOP WORK OF SPECIFIC

CONSTRUCTION OPERATIONS SHOULD THE OWNER IDENTIFY AN EMERGENCY OR DANGER

EXISTS TO THE WELFARE OF THE OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.

E. SCHEDULE ALL WORK PRODUCING EXCESS NOISE OR VIBRATIONS WITH C.O.R. IN ADVANCE SO

AS TO NOT DELAY PROGRESS OF THE WORK.

F. SCHEDULE ALL WORK REQUIRING DISRUPTION TO BUILDING UTILITIES WITH C.O.R. IN ADVANCE

SO AS TO NOT DELAY PROGRESS OF THE WORK.

G. PATCH ALL FLOORS, WALLS, AND CEILINGS ALTERED DURING CONSTRUCTION AS REQ'D TO

MATCH EXISTING. PATCH ANCHOR HOLES IN MASONRY WALL WHERE ACCESSORIES HAVE BEEN

MOVED AND/OR OMITTED.

H. COORDINATE MOUNTING LOCATIONS OF ALL WALL-MOUNTED DEVICES AND/OR EQUIPMENT IN

ORDER TO ELIMINATE CONFLICTS.

I. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING/ANCHORAGE FOR WALL-MOUNTED

EQUIPMENT AND/OR ACCESSORIES.

J. REFERENCE PLUMBING DRAWINGS FOR EXACT LOCATIONS OF FLOOR DRAINS.

K. PROVIDE CONTROL JOINTS ON CONTINUOUS GYPSUM BOARD SURFACES IN EXCESS OF 30'-0", AT

A MAXIMUM INCREMENT OF 30'-0" ON CENTER, U.N.O. INCORPORATE CONTROL JOINTS AT DOOR

AND WINDOW FRAMES.

L. REFERENCE SHEET A-502 FOR TYPICAL COLUMN DETAILS.

M. ANY EXISTING EXTERIOR WINDOWS PLACED BEHIND NEW WALLS SHALL BE "BLACKED OUT" TO

OUTSIDE VIEW.

LINETYPE LEGEND

LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN

HEAVY SOLID LINE INDICATES NEW ELEMENT

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:3

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-101

OVERALL IMPROVEMENT PLANS Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 16' 32'8'1/16" = 1'-0"A

IMPROVEMENT PLAN - BASEMENT - OVERALL

0 16' 32'8'1/16" = 1'-0"B

IMPROVEMENT PLAN - FIRST FLOOR - OVERALL

N

A-201

A

MSA

A103

LOBBY

A101

CHILDREN'S WAITING

A104

P. TLT.

A105

VESTIBULE

A100

A-201

C

A-201

E

A-201

F

A-201

D

VESTIBULE

A102

HOLD

D101

CONSULT

D102

BHIP OFFICE

D103

BHIP OFFICE

D104

BHIP OFFICE

D105

BHIP OFFICE

D106

IT

D107

CWT OFFICE

D108

P. TLT.

D110

P. TLT.

D111

BHIP OFFICE

D112 STAFF WORK

D113

CONF / CLASS

D114

BHIP OFFICE

D115

BHIP OFFICE

D116

BHIP OFFICE

D117

BHIP OFFICE

D118

BHIP OFFICE

D119

BHIP OFFICE

D120

BHIP OFFICE

D121

BHIP OFFICE

D122

BHIP OFFICE

D123

BHIP OFFICE

D124

BHIP OFFICE

D125

BHIP OFFICE

D126

BHIP OFFICE

D127

BHIP OFFICE

D128

BHIP OFFICE

D129

BHIP OFFICE

D130

CONF

D131

BHIP OFFICE

D132

BHIP OFFICE

D133

BHIP OFFICE

D134

CORRIDOR

1CDR10

HALL

D136

CORRIDOR

1CDR11

ELEC

D137

21 22.7 25.4 32.5 33.3 33.8

33.8

L.5

M

P

P.5

29.1

O.5

N.5

N

O

27 30.928.522.2

L

J.8

J

L (E)

K.8

A-301

A-301

A-301

A-301

A-301

4B

4A 4A

4A

4A

4A 4A

4A

4A

4A

4A

4A

4A

4B

4A

4A

2A

2A2A

2A

6B

2D

6B

6B

A103B

A101

A102D

D108

D129D130

D125D124

D117 D116

D107D106D104 D105D102 D103D101

D122D121

D119D120

D131BD132D133D134 D131A

D109C

D126

D115

D123

D118

D113

D128

D127

D114B

D114A

D112

A131A

D137

A102

2D

2C

2C

4A

4A

4A

4A

4A

4A

4A

4A

4D

4A4D

4D

4A

4A

4A

4A

4A

4A4A 4A

4A

4A

4A

4A 4A 4A4A

4A

4A

4A

4A

4A

4A

4A

4A

4B

4A

3D3D

3C

2A

2A

2C

ALCOVE

A106

4A4B4A4A

4A 4B 4A4B4A4A

4A

3A

3A

1 1

3C

HSK

D138

A-301

A-301

A103A

CW3CW3

A102A A102BCW4 CW5

CW6

SF1SF1SF2 SF1 SF1

SF1 SF1

SF1

SF1

SF1

SF1 SF1SF1SF1SF1

SF1

SF1

SF1

SF3

SF4

4B 3A

5A

5A

5A

2A

2A

A-502

3A

A-502

A-502

A-502

SIM

A-311

5A5A 5A5A

3C

3C

2A

5A5A

5A

5A

3A

3A

A-401

A-401

A-502

A100A

CW1

CW2

A100B

VESTIBULE

D109

A-301

A-301

E2 E1

D138

A-501

A-501

6A

A-501

SIM

A-501

SIM

A-501

SIM

5A5A

3A

5A5A

3A

3C3C

3C3C

5A

5A

5A

D109BCW7 CW7 D109A

M.9

L.9

M.3

EXTERIOR WALL

TYPE SEPARATION 3C

A-502

3C 3C A-502

A-502

OPP

A-502

SIM

OPP

A-502

SIM

5 5

3C3C

EXTERIOR WALL

TYPE SEPARATION

E2 E1E2

E1

HALL

A131

2A

E3

E3

A-501

A-501

3C

A-502

6C

A-201

I

21.1

4A

4A

4A4A

4A 4A

2A

2A 2B

3A

3D

A-401

A-401

62 SF

S. TLT.

C131

62 SF

S. TLT.

C130

A-401

140 SF

P. TLT.

A128

139 SF

P. TLT.

A129

373 SF

SUD GROUP

THERAPY

C136

14 SF

DRINKING

FOUNTAIN

A130

149 SF

SUD OFFICE

C134

137 SF

SUD OFFICE

C133

68 SF

P. TLT.

C126

77 SF

P. TLT.

C125

58 SF

STOR.

C132

4A

2B5A

3A3A

2A

5A

C136 C134 C133 C126

C131

C128

C129

C127

1CDR7

A128A129 C125

2A 4A

2A

2A

6A

2A

6A

2A

269 SF

STAFF LOUNGE

C129

124 SF

STOR.

C127

162 SF

CAROTAS

C128

A-311

A-502

A-502

SIM

C130

A105

5A

C135

C132

LINETYPE LEGEND

LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN

HEAVY SOLID LINE INDICATES NEW ELEMENT

FLOOR PLAN GENERAL NOTES

A. ALL INFECTION CONTROL CRITERIA AS SPECIFIED IN SECTION 01 35 26 SHALL BE ADHERED TO

DURING ALL PHASES OF THE PROJECT.

B. CONTRACTOR SHALL ERECT AND MAINTAIN A RATED SEPARATION DURING ALL CONSTRUCTION

PHASES, AS REQUIRED ON THE LIFE SAFETY DRAWINGS.

C. CONTRACTOR SHALL FIELD-LOCATE THE TEMPORARY WALLS AND DOORS AND COORDINATE

LOCATION WITH THE C.O.R. PROVIDE CONSTRUCTION SAFETY SIGNAGE AT ALL ENTRANCES TO

CONSTRUCTION AREAS, SEE SIGNAGE DRAWINGS FOR ADDITIONAL INFORMATION.

D. RENOVATION WORK SHALL BE COMPLETED WITH MINIMAL DISRUPTION TO BUILDING

OPERATIONS. THE OWNER RESERVES THE RIGHT TO TEMPORARILY STOP WORK OF SPECIFIC

CONSTRUCTION OPERATIONS SHOULD THE OWNER IDENTIFY AN EMERGENCY OR DANGER

EXISTS TO THE WELFARE OF THE OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.

E. SCHEDULE ALL WORK PRODUCING EXCESS NOISE OR VIBRATIONS WITH C.O.R. IN ADVANCE SO

AS TO NOT DELAY PROGRESS OF THE WORK.

F. SCHEDULE ALL WORK REQUIRING DISRUPTION TO BUILDING UTILITIES WITH C.O.R. IN ADVANCE

SO AS TO NOT DELAY PROGRESS OF THE WORK.

G. PATCH ALL FLOORS, WALLS, AND CEILINGS ALTERED DURING CONSTRUCTION AS REQ'D TO

MATCH EXISTING. PATCH ANCHOR HOLES IN MASONRY WALL WHERE ACCESSORIES HAVE BEEN

MOVED AND/OR OMITTED.

H. COORDINATE MOUNTING LOCATIONS OF ALL WALL-MOUNTED DEVICES AND/OR EQUIPMENT IN

ORDER TO ELIMINATE CONFLICTS.

I. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING/ANCHORAGE FOR WALL-MOUNTED

EQUIPMENT AND/OR ACCESSORIES.

J. REFERENCE PLUMBING DRAWINGS FOR EXACT LOCATIONS OF FLOOR DRAINS.

K. PROVIDE CONTROL JOINTS ON CONTINUOUS GYPSUM BOARD SURFACES IN EXCESS OF 30'-0", AT

A MAXIMUM INCREMENT OF 30'-0" ON CENTER, U.N.O. INCORPORATE CONTROL JOINTS AT DOOR

AND WINDOW FRAMES.

L. REFERENCE SHEET A-502 FOR TYPICAL COLUMN DETAILS.

M. ANY EXISTING EXTERIOR WINDOWS PLACED BEHIND NEW WALLS SHALL BE "BLACKED OUT" TO

OUTSIDE VIEW.

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

SHEET KEYNOTES

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:4

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-102

IMPROVEMENT PLAN - FIRST FLOOR Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"A

IMPROVEMENT PLAN - FIRST FLOOR

N

1 ADD 7-MIL ANTI-SHATTER WINDOW FILM TO INTERIOR FACE OF GLAZING. ATTACH TO WINDOW FRAME ON

ALL 4 SIDES WITH STRUCTURAL SILICONE. FOLLOW MANUFACTURER INSTRUCTIONS ON WINDOW

PREPARATION.

2 CONTINUE GYP. BD. ON EXISTING WALL TO WINDOW MULLION.

3 RATED PARTITION TO BE CONTINUOUS.

4 ROOF LADDER

5 DIVIDER PARTITIONS. REF. INTERIOR DRAWINGS.

21 22.7 25.4 32.5 33.3 33.8

33.8

L.5

M

P

P.5

29.1

O.5

N.5

N

O

27 30.928.522.2

L

J.8

J

L (E)

K.8

MSA

A103

LOBBY

A101

CHILDREN'S WAITING

A104

P. TLT.

A105

VESTIBULE

A100

VESTIBULE

A102

HALL

A131

HOLD

D101

CONSULT

D102

BHIP OFFICE

D103

BHIP OFFICE

D104

BHIP OFFICE

D105

BHIP OFFICE

D106

IT

D107

CWT OFFICE

D108

VESTIBULE

D109

P. TLT.

D110

P. TLT.

D111

BHIP OFFICE

D112 STAFF WORK

D113

CONF / CLASS

D114

BHIP OFFICE

D115

BHIP OFFICE

D116

BHIP OFFICE

D117

BHIP OFFICE

D118

BHIP OFFICE

D119

BHIP OFFICE

D120

BHIP OFFICE

D121

BHIP OFFICE

D122

BHIP OFFICE

D123

BHIP OFFICE

D124

BHIP OFFICE

D125

BHIP OFFICE

D126

BHIP OFFICE

D127

BHIP OFFICE

D128

BHIP OFFICE

D129

BHIP OFFICE

D130

CONF

D131

BHIP OFFICE

D132

BHIP OFFICE

D133

BHIP OFFICE

D134

CORRIDOR

1CDR10

HALL

D136

CORRIDOR

1CDR11

ELEC

D137

ALCOVE

A106

HSK

D138

7' - 8" 9' - 4" +/- 10' - 4" 10' - 2" 10' - 2" 10' - 2" 10' - 7"

HOLD

8' - 1" 10' - 6" 10' - 6" 10' - 6" +/- 5' - 5" 10' - 6" 10' - 6" 10' - 6" 8' - 6"

11" 10' - 0" 10' - 6" +/- 11' - 6"

9'

8'

9" 8'

9"

3'

8"

+/- 8' - 7" +/- 4' - 9"

11" 13' - 2"

- 2

4'

9"

1'

1"

3'

4" 8'

8"

1'

4" 4'

0"

5'

4"

1'

8" 5'

4" 3'

8"

1'

8" 8"

8" 1'

8"

2'

8" 5'

4"

1'

4"5'

4"1'

4" 1'

4"

20' - 8" 32' - 0" 33' - 4" 21' - 4" 13' - 6" 11' - 2"

132' - 0"

7'

F .V

/2

2" E

J

10' - 0" 3' - 4" 1' - 4" 5' - 4" 4' - 8" 5' - 4" 4' - 8" 5' - 4" 5' - 4" 5' - 4"

5"

51' - 1" 3' - 3"

" +/- 10' - 2"

24' - 9" F.V.

2'

4" 5'

4"

2'

0"

6'

4" F

.V

M.9

L.9

M.3

3'

4" 8'

8"

1'

4"

5'

4"

3'

4" 5'

4"

3'

4" 5'

4"

8'

0" 1'

4"

1/ 2"

1'

4"

1' - 4" 19' - 4" 1' - 4" 4' - 0" 5' - 4" 3' - 4" 5' - 4" 3' - 4" 5' - 4" 4' - 0"

1' - 8" 8"

28' - 8"

8" 1' - 8"

4' - 0" 5' - 4" 1' - 4" 5' - 4" 4' - 0" 1' - 4" 12' - 2" 1' - 4" 7' - 10" 3' - 4"

+/- 22' - 10"

+/- 10' - 1"

9'

9"

ALIGN

ALIGN

A

LI

G N

1' - 2"11"

CENTER WALL ON

COLUMN GRID

ALIGN

CENTER WALL ON

COLUMN GRID

ALIGN

CENTER WALL ON

COLUMN GRID

ALIGN

CENTER WALL ON

COLUMN GRID

ALIGN

A

LI

G N

10' - 10"+/- 29' - 7" +/- 11' - 10"

CENTER WALL ON

COLUMN GRID

ALIGN

CENTER WALL ON

COLUMN GRID

ALIGN

E Q

E Q

H O

LD

8'

0"

11"

H O

LD

8'

2"

HOLD

8' - 2"

HOLD

6' - 2"

ALIGN

4'

HOLD

8' - 1"

A

LI

G N

ALIGN

ALIGN

ALIGN

0"

0"

CENTER WALL ON

COLUMN GRID

HOLD

8' - 0"

E Q

E Q

EQ EQ

EQ EQ

3' - 5 1/2"

21.1

139 SF

P. TLT.

A129

140 SF

P. TLT.

A128

373 SF

SUD GROUP

THERAPY

C136

149 SF

SUD OFFICE

C134

137 SF

SUD OFFICE

C133

77 SF

P. TLT.

C125

68 SF

P. TLT.

C126

124 SF

STOR.

C127

162 SF

CAROTAS

C128

269 SF

STAFF LOUNGE

C129

62 SF

S. TLT.

C130

62 SF

S. TLT.

C131

58 SF

STOR.

C132

2089 SF

COURTYARD

D135

8'

5"

3/ 8"

7'

3/

4" 8'

1/ 4"

8'

1/

2"

/8

11' - 10 5/8" 10' - 0 1/4" 9' - 6 5/8" 7/8" 25' - 8" 9' - 10" 8' - 11 5/8"

8' - 1 1/4"

17' - 8 5/8"

8'

1" 8'

3/ 4"

9'

1/

8"

/8

8' - 6 1/2" 10' - 9 5/8"

9'

1/

4"

C

LR

8'

1"

12' - 11"

DIMENSION GENERAL NOTES

A. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD, CENTER LINE OF COLUMN GRID, OR FINISH FACE OF EXISTING WALLS AND COLUMN SURROUNDS, U.N.O.

B. ALL DIMENSION OF EXISTING CONSTRUCTION ARE TO PROVIDE CONTRACTOR WITH

APPROXIMATE SIZES AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL

DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTOR PRIOR TO THE START OF

CONSTRUCTION.

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

LINETYPE LEGEND

LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN

HEAVY SOLID LINE INDICATES NEW ELEMENT

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:4

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-103

DIMENSION PLAN - FIRST FLOOR Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"A

DIMENSION PLAN - FIRST FLOOR

S

S

S S

C

S S S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

C S

S

S

S

S

S

S S

S

S

S

S S

C

C

S

S

S

C

S

S

S

S

NOTE: NO ARCHITECTURAL IMPROVEMENT ON BASEMENT

CEILINGS. REPAIR CEILING GRID AND REPLACE ANY CEILING

TILES TO MATCH WITH EXISTING. THAT WERE DAMAGED

DURING DEMOLITION OF ABOVE CEILING WORK.

A-301

A-301

A-301

A-301

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

CEILING PLAN GENERAL NOTES

A. REFERENCE ELECTRICAL AND MECHANICAL DRAWINGS FOR FINAL FIXTURE LOCATIONS AND

QUANTITIES. ARCHITECTURAL CEILING PLANS ARE INTENDED TO SHOW FIXTURE LOCATIONS IN

CEILING GRID AND CEILINGS AND SHOULD NOT BE USED TO DETERMINE ELECTRICAL AND

MECHANICAL REQUIREMENTS.

B. CENTER LIGHTS, DIFFUSERS, EXIT SIGNS, SMOKE DETECTORS, SPRINKLER HEADS, SPEAKERS, GENERAL ALARM, AND MISC. CEILING-MOUNTED DEVICES IN CEILING TILES WHERE THEY ARE

LOCATED U.N.O.

C. REFERENCE FINISH SCHEDULE I-601 FOR ADDITIONAL INFORMATION.

CEILING PLAN LEGEND

PLASTER,

GYPSUM OR

PORTLAND CEMENT

WOOD PLANK CEILING

SEE DETAIL ON SHEET

A-511 FOR LIGHTING AT

WOOD PLANK CEILING

EXIT SIGN,

CEILING MOUNTED

(DIRECTIONAL ARROW)

1' - 0"

CEILING

ELEVATION TAG

RETURN AIR, CEILING

SUPPLY AIR, CEILING

LIGHT FIXTURE,

RECESSED 2X4

TILE,

ACOUSTICAL CEILING

LIGHT FIXTURE,

RECESSED (1X4, 1X6)

LIGHT FIXTURE,

RECESSED 2X2

LINEAR SUSPENDED

FIXTURE 1X4

WALL FIXTURE

(INTERIOR)

WALL FIXTURE

(EXTERIOR)

METAL SOFFIT PANEL

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:5

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-111

OVERALL REFLECTED CEILING

PLANS

Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 16' 32'8'1/16" = 1'-0"A

REFLECTED CEILING PLAN - BASEMENT - OVERALL

0 16' 32'8'1/16" = 1'-0"B

REFLECTED CEILING PLAN - FIRST FLOOR - OVERALL

N

S

S

S

S

P. TLT.

A128

SUD GROUP

THERAPY

C136

SUD OFFICE

C134

SUD OFFICE

C133

S. TLT.

C131

S. TLT.

C130

P. TLT.

C126

P. TLT.

C125

STOR.

C127

CAROTAS

C128

STAFF LOUNGE

C129

STOR.

C132

P. TLT.

A129

MSA

A103

CHILDREN'S WAITING

A104

P. TLT.

A105

ALCOVE

A106

VESTIBULE

A100

DRINKING FOUNTAIN

A130

VESTIBULE

A102

HALL

A131

HOLD

D101

CONSULT

D102

BHIP OFFICE

D103

BHIP OFFICE

D104

BHIP OFFICE

D105

BHIP OFFICE

D106

IT

D107

CWT OFFICE

D108

P. TLT.

D110

P. TLT.

D111

BHIP OFFICE

D112

STAFF WORK

D113

CONF / CLASS

D114

BHIP OFFICE

D115

BHIP OFFICE

D116

BHIP OFFICE

D117

BHIP OFFICE

D118

BHIP OFFICE

D119

BHIP OFFICE

D120

BHIP OFFICE

D121

BHIP OFFICE

D122

BHIP OFFICE

D123

BHIP OFFICE

D124

BHIP OFFICE

D125

BHIP OFFICE

D126

BHIP OFFICE

D127

BHIP OFFICE

D128

BHIP OFFICE

D129

BHIP OFFICE

D130

CONF

D131

BHIP OFFICE

D132

BHIP OFFICE

D133

BHIP OFFICE

D134

CORRIDOR

1CDR10

HALL

D136

CORRIDOR

1CDR11

CORRIDOR

1CDR7

ELEC

D137

A-301

A-301

A-301

A-301

A-301

LOBBY

A101

ALCOVE

A106

9' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0" 9' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0"9' - 0"9' - 0"

9' - 0"

9' - 0" 9' - 0"

9' - 0" 9' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0" 9' - 0"

9' - 0" 9' - 0"

9' - 0"

9' - 0"

8' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"9' - 0"9' - 0"9' - 0"9' - 0"

9' - 0"

9' - 0"

9' - 0"

8' - 0"

9' - 0"

9' - 2"

9' - 0"

7' - 11"

9' - 0"

9' - 0"

EXPOS

VESTIBULE

D109

9' - 0"

EXPOS

8'

0"

9' - 0"

8' - 0"

HSK

D138

EXPOS

9' - 0"

A-301

A-301

A-511

7' - 0"

7' - 0"

3 2

1 1

7' - 0"

9' - 0"

9' - 0"

9' - 0"

A-521

A-511

A-5116

A-511

A-511

A-511

A-511

A-511

A-511

9' - 0"

9' - 0"

9' - 0"

9' - 6"

A-301

A-301

EQ EQ EQ EQ EQ EQ EQ

A-521

A-521

A-521

A-511

A-511

A-521

9' - 0"

7 7 7

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

9' - 0"1

A-511

8' - 2"

A-521

CEILING PLAN GENERAL NOTES

A. REFERENCE ELECTRICAL AND MECHANICAL DRAWINGS FOR FINAL FIXTURE LOCATIONS AND

QUANTITIES. ARCHITECTURAL CEILING PLANS ARE INTENDED TO SHOW FIXTURE LOCATIONS IN

CEILING GRID AND CEILINGS AND SHOULD NOT BE USED TO DETERMINE ELECTRICAL AND

MECHANICAL REQUIREMENTS.

B. CENTER LIGHTS, DIFFUSERS, EXIT SIGNS, SMOKE DETECTORS, SPRINKLER HEADS, SPEAKERS, GENERAL ALARM, AND MISC. CEILING-MOUNTED DEVICES IN CEILING TILES WHERE THEY ARE

LOCATED U.N.O.

C. REFERENCE FINISH SCHEDULE I-601 FOR ADDITIONAL INFORMATION.

CEILING PLAN LEGEND

PLASTER,

GYPSUM OR

PORTLAND CEMENT

WOOD PLANK CEILING

SEE DETAIL ON SHEET

A-511 FOR LIGHTING AT

WOOD PLANK CEILING

EXIT SIGN,

CEILING MOUNTED

(DIRECTIONAL ARROW)

1' - 0"

CEILING

ELEVATION TAG

RETURN AIR, CEILING

SUPPLY AIR, CEILING

LIGHT FIXTURE,

RECESSED 2X4

TILE,

ACOUSTICAL CEILING

LIGHT FIXTURE,

RECESSED (1X4, 1X6)

LIGHT FIXTURE,

RECESSED 2X2

LINEAR SUSPENDED

FIXTURE 1X4

WALL FIXTURE

(INTERIOR)

WALL FIXTURE

(EXTERIOR)

METAL SOFFIT PANEL

SHEET KEYNOTES

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:0

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-112

REFLECTED CEILING PLANS - FIRST

FLOOR

Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"A

REFLECTED CELILING PLAN - FIRST FLOOR

N

1 EXISTING CONCRETE CANOPY.

2 PRE-FINISHED METAL SOFFIT.

3 ROOF HATCH

4 CEILING TO CEILING EJ COVER - BALCO 75FCA OR EQUAL.

5 RE: DETAIL ON SHEET A-501 FOR DETAIL WHERE EXISTING CONCRETE CANOPY IS REMOVED TO

ACCOMMODATE NEW CONSTRUCTION.

6 DIVIDER PARTITIONS. REF. INTERIOR DRAWINGS.

7 18"x18" ACCESS PANEL, PAINTED TO MATCH SOFFIT. COORDINATE EXACT PLACEMENT WITH OVERHEAD

DOOR MANUFACTURER.

8 24"x24" ACCESS PANEL, PAINTED TO MATCH CEILING. COORDINATE EXACT PLACEMENT WITH DAMPER

LOCATION. DETAIL ON SHEET A -511

10 METAL PANEL REVEALS TYP.

OS

OSOS

/4

/4

/4

/4

1/4" / 1'-0" 1/4" / 1'-0" 1 /4

/4

1/4" / 1'-0" 1/4" / 1'-0"

/4

1/4" / 1'-0"

1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0"

1/4" / 1'-0"

/4

/4

/4

1/4" / 1'-0"

A-301

A-301

A-301

A-301

A-301

A-301

1/4" / 1'-0"1/ 4"

1' -0

1/4" / 1'-0"1/4" / 1'-0"

/4

/4

1/4" / 1'-0" 1/4" / 1'-0"

1/4" / 1'-0"1/4" / 1'-0"

/4

1/4" / 1'-0"

/4

1/4" / 1'-0"

A-301

A-301

/4

/4

A-521

A-521

A-522

A-521

A-301

A-301

A-522

D.S.

D.S.

D.S.

D.S.

D.S.

A-522

A-521

SIM

EXISTING BUILDING

EXISTING BUILDING

13 1313

A-522

A-522

SIM

9 2

A-521

1/4" / 1'-0"

1/4" / 1'-0"

ROOF PLAN GENERAL NOTES

A. ALL ROOFTOP MECHNICAL EQUIPMENT SHOWN ARE FOR REFERENCE ONLY. REF. MECHANICAL

DRAWINGS FOR EXACT LOCATIONS.

B. REF. STRUCTURAL DRAWINGS FOR ALL ROOF OPENING LOCATIONS AND DETAILS.

C. REF. STRUCTURAL DRAWINGS FOR RTU SCREEN WALL STRUCTURAL SUPPORTS.

D. 5" MIN. ROOF INSULATION THICKNESS.

SHEET KEYNOTES

HATCH LEGEND

NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING

AREA NOT IN SCOPE

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:2

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-121

PARTIAL ROOF PLAN Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"A

ROOF PLAN

N

1 ROOFTOP SCREENING UNIT. REF. STRUCT. AND EXTERIOR ELEVATIONS FOR MORE INFORMATION.

2 ROOFTOP UNIT, REF. MECH.

3 COMBINATION ROOF DRAIN/EMERGENCY DRAIN. REF. DETAIL ON SHEET A-521. COORDINATE FINAL

LOCATION WITH STRUCTURE.

4 5" ALUMINUM GUTTER AND DOWNSPOUT WITH CAST IRON BOOT.

5 EXISTING TPO ROOF TO REMAIN. PATCH AND REPAIR AS REQ'D TO INSTALL NEW RTU AND SCREEN.

MAINTAIN EXISTING ROOF WARRANTY.

9 ROOFTOP WALK PAD.

10 EXPANSION JOINT, REF. STRUCT.

11 30" X 36" ROOF HATCH.

12 EXHAUST FAN, REF. MECH.

13 EXISTING CONCRETE CANOPY.

14 APPLY NEW INSULATION AND TPO MEMBRANE TO SLOPE ROOF DRAINAGE TO EXISTING DOWN SPOUT

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

A-301

A-301

SF1SF1SF1

CW4

A102A

JOIST BRG.

112' - 5 1/2"

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

T.O. RTU SCREEN 124' - 10"

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

A-301

A-301

SF3SF1SF1 SF1 SF1

10 10

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

88 88

D109A

1 1

111212 12

T.O. RTU SCREEN 124' - 10"

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

A-301

A-301

A-301

A-511

SF1 SF1 SF1 SF4 SF1 SF1

A-522

JOIST BRG.

112' - 5 1/2"

CANOPY JOIST BEARING

112' - 9 1/2"

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

T.O. RTU SCREEN 124' - 10"

111 1 1

12 12 12 12

JOIST BRG.

111' - 0"

1 1

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

A-301

A-301

SF1 SF1 SF1 SF1 SF2

10 10

JOIST BRG.

112' - 5 1/2"

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

88888

1 1 1

12 12

T.O. RTU SCREEN 124' - 10"

VESTIBULE

D109

VESTIBULE

A102

1 1 1

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

SF17

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

D109B

FIN. FLOOR

100' - 0"

A-301

A-301

CW6

CW5

A102B

111111

JOIST BRG.

111' - 0"22

A-521

SHEET KEYNOTES

FIN. FLOOR

100' - 0"

CW8

1CDR2

FIN. FLOOR

100' - 0"

BRICKS INDICATED IN BOLD

LINE SHALL PROTRUDE 1/2"

GENERAL NOTES

A. ALL INFECTION CONTROL CRITERIA AS SPECIFIED IN SECTION 01 35 26 SHALL BE ADHERED TO

DURING ALL PHASES OF THE PROJECT.

B. CONTRACTOR SHALL ERECT AND MAINTAIN A RATED SEPARATION DURING ALL CONSTRUCTION

PHASES, AS REQUIRED ON THE LIFE SAFETY DRAWINGS.

C. CONTRACTOR SHALL FIELD-LOCATE THE TEMPORARY WALLS AND DOORS AND COORDINATE

LOCATION WITH THE C.O.R. PROVIDE CONSTRUCTION SAFETY SIGNAGE AT ALL ENTRANCES TO

CONSTRUCTION AREAS, SEE SIGNAGE DRAWINGS FOR ADDITIONAL INFORMATION.

D. RENOVATION WORK SHALL BE COMPLETED WITH MINIMAL DISRUPTION TO BUILDING

OPERATIONS. THE OWNER RESERVES THE RIGHT TO TEMPORARILY STOP WORK OF SPECIFIC

CONSTRUCTION OPERATIONS SHOULD THE OWNER IDENTIFY AN EMERGENCY OR DANGER

EXISTS TO THE WELFARE OF THE OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.

E. SCHEDULE ALL WORK PRODUCING EXCESS NOISE OR VIBRATIONS WITH C.O.R. IN ADVANCE SO

AS TO NOT DELAY PROGRESS OF THE WORK.

F. SCHEDULE ALL WORK REQUIRING DISRUPTION TO BUILDING UTILITIES WITH C.O.R. IN ADVANCE

SO AS TO NOT DELAY PROGRESS OF THE WORK.

G. PATCH ALL FLOORS, WALLS, AND CEILINGS ALTERED DURING CONSTRUCTION AS REQ'D TO

MATCH EXISTING. PATCH ANCHOR HOLES IN MASONRY WALL WHERE ACCESSORIES HAVE BEEN

MOVED AND/OR OMITTED.

H. COORDINATE MOUNTING LOCATIONS OF ALL WALL-MOUNTED DEVICES AND/OR EQUIPMENT IN

ORDER TO ELIMINATE CONFLICTS.

I. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING/ANCHORAGE FOR WALL-MOUNTED

EQUIPMENT AND/OR ACCESSORIES.

J. REFERENCE PLUMBING DRAWINGS FOR EXACT LOCATIONS OF FLOOR DRAINS.

K. PROVIDE CONTROL JOINTS ON CONTINUOUS GYPSUM BOARD SURFACES IN EXCESS OF 30'-0", AT

A MAXIMUM INCREMENT OF 30'-0" ON CENTER, U.N.O. INCORPORATE CONTROL JOINTS AT DOOR

AND WINDOW FRAMES.

L. REFERENCE SHEET A-502 FOR TYPICAL COLUMN DETAILS.

M. EXTERIOR FINISH FACE BRICK IS FB-1. TYPICAL UNLESS OTHERWISE NOTED ON ELEVATIONS.

BLEND EQUAL TO CLOUD CERAMICS CORONADO (75%) AND DOVE GREY (25%).

N. CONTRACTOR TO FILL CAVITIES LEFT IN EXISTING WALLS AFTER DEMOLITION

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:3

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-201

EXTERIOR ELEVATIONS Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"A

NORTH ELEVATION

0 8' 16'4'1/8" = 1'-0"B

SOUTH ELEVATION

0 8' 16'4'1/8" = 1'-0"C

WEST ELEVATION

0 8' 16'4'1/8" = 1'-0"E

COURTYARD_WEST ELEVATION

0 8' 16'4'1/8" = 1'-0"D

COURTYARD_SOUTH ELEVATION

0 8' 16'4'1/8" = 1'-0"F

SOUTH ELEVATION

1 BRICK MASONRY CONTROL JOINT.

2 FACE BRICK FB-1. BLEND EQUAL TO CLOUD CERAMICS CORONADO (75%) AND DOVE GREY (25%).

3 BRICK AT THIS LOCATION SHALL FOLLOW PATTERN ON DETAIL J THIS SHEET.

4 MECHANICAL EQUIPMENT, RE. MECH.

5 PREFINISHED METAL PANEL ROOFTOP SCREEN. 7.2 HORIZONTAL RIBBED. MAINTAIN A MINIMUM OF 24" CLEARANCE FROM BOTTOM OF METAL PANEL TO TOP OF ROOF SYSTEM. PAINT STRUCTURE TO MATCH.

6 PREFINISHED METAL GUTTER.

7 BRICK INFILL, SAWTOOTH EDGES WITH EXISTING BRICK.

8 PREFINISHED BRAKE METAL TRIM. COLOR TO MATCH CURTAIN MULLION.

9 PREFINISHED METAL COPING CAP.

10 BRICK MASONRY ACCENT, RE. WALL SECTIONS.

11 PREFINISHED METAL DOWNSPOUT W/ CAST IRON BOOT, RE. CIVIL.

12 OVERFLOW ROOF DRAIN OUTLET. REF. PLUMBING DRAWINGS

13 PREFINISHED METAL FASCIA.

14 EXISTING BUILDING

15 METAL WALL PANEL

17 EXISTING SCUPPER AND DOWNSPOUT

18 NOT USED

19 NOT USED

20 NEW CANOPY

21 EXISTING SCUPPER AND DOWNSPOUT TO REMAIN

22 PONY WALL ENCLOSING NEW ROOF AREA AND EXISTING ROOF

0 8' 16'4'1/8" = 1'-0"G

EXISTING ELEVATION @LOUVER

0 8' 16'4'1/8" = 1'-0"I

ELEVATION @ EXT STAIR

0 1' 1 1/2'1/2'1 1/2" = 1'-0"J

EXT DTL - BRICK PATTERN

ROOF 137-9 3/4

137' - 9 3/4"

T.O. PARAPET

117' - 4"

M P P.5O.5N OK(E)J(E)

A-301

A-301

IT

D107

CONF

D131

CWT OFFICE

D108

VESTIBULE

D109

A-311

A-311

A-521

7 A-521

JOIST BRG.

114' - 4 7/8"

JOIST BRG.

112' - 5 1/2"

JOIST BRG.

114' - 7 3/8"

JOIST BRG.

111' - 6"

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

T.O. RTU SCREEN 124' - 10"

CORRIDOR

1CDR10

BHIP OFFICE

D117

BHIP OFFICE

D124

CORRIDOR

1CDR11

A-511

SUD OFFICE

C133

STOR.

C132

S. TLT.

C131

S. TLT.

C130

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

22.7 25.4 32.5 33.329.127 30.928.5

A-301

A-301

CORRIDOR

1CDR11

BHIP OFFICE

D121

BHIP OFFICE

D122

BHIP OFFICE

D123

HALL

D136

BHIP OFFICE

D124

BHIP OFFICE

D125

BHIP OFFICE

D126

CORRIDOR

1CDR11

BHIP OFFICE

D127

A-311

A-311

5 OPP

FIN. FLOOR

100' - 0"

21 22.2

HALL

A131

A-311

A-511

A-522

JOIST BRG.

111' - 0"

21.1

FIN. FLOOR

100' - 0"

A-301

A-301

CANOPY JOIST BEARING

112' - 9 1/2"

A-522

M.9 L.9

VESTIBULE

A100

FIN. FLOOR

100' - 0"

A-301

A-301

CANOPY JOIST BEARING

112' - 9 1/2"

20 19

A-522

SIMSIM

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

ISSUED FOR BID

/2

/2

:5

:3

P

M A u to d e s k D o c s /1

.2

A tr ia x T o p e k a

V A

M e n ta l H e a lt h C lin ic

(M o d

.2

A

A tr ia x

T o p e k a V

A M e n ta l H e a lt h C lin ic

(M O

D

V

.r v t

A-301

BUILDING SECTIONS Outpatient Mental Health Clinic

Colmery-O'Neil VAMC Topeka, KS

589-501

03/29/24 FAB LD

0 8' 16'4'1/8" = 1'-0"1

BUILDING SECTION

0 8' 16'4'1/8" = 1'-0"2

BUILDING SECTION

0 8' 16'4'1/8" = 1'-0"3

BUILDING SECTION

0 8' 16'4'1/8" = 1'-0"4

CANOPY SECTION

0 8' 16'4'1/8" = 1'-0"5

CANOPY SECTION

T.O. PARAPET

117' - 4"

L.5

A-521

PARTITION TYPED AS

SCHEDULED

JOIST BRG.

114' - 4 7/8"

JOIST BRG.

111' - 6"

VAPOR BARRIER

GRANULAR FILL

PERIMETER INSULATION

CONCRETE FOUNDATION

REF. STRUC.

SIM

STEEL BEAM,

REF. STRUCT.

CONTINUE RATED

PARTITION TO DECK

ABOVE, EACH SIDE

SUSPENDED

ACOUSTICAL TILE

CEILING

CONCRETE SLAB -

REF. STRUCT.

SUSPENDED

ACOUSTICAL TILE

CEILING

FIN. FLOOR

100' - 0"

P.5

A-501

A-551

A-551

FACE BRICK WALL TYPE 'E1'

REF. EXTERIOR ELEVATIONS

FOR BRICK PATTERN

STOREFRONT WINDOW

REF. EXTERIOR ELEVATIONS

AND SCHEDULE

A-521

OPP

OPP

OPP

VAPOR BARRIER

GRANULAR FILL

PERIMETER INSULATION

CONCRETE FOUNDATION

REF. STRUC.

JOIST BRG.

112' - 5 1/2"

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

CONCRETE SLAB -

REF. STRUCT.

SUSPENDED

ACOUSTICAL TILE

CEILING

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

22.7

A-501

A-551

A-501

A-501

A-551

FACE BRICK WALL TYPE 'E1'

REF. EXTERIOR ELEVATIONS

FOR BRICK COLOR TYPE

STOREFRONT WINDOW

REF. EXTERIOR ELEVATIONS

AND SCHEDULE

VAPOR BARRIER

GRANULAR FILL

PERIMETER INSULATION

CONCRETE FOUNDATION

REF. STRUC.

VARIES

STOREFRONT HEAD

108' - 8"

STOREFRONT SILL

102' - 8"

CONCRETE SLAB -

REF. STRUCT.

FIN. FLOOR

100' - 0"

CURTAIN WALL

REF. EXTERIOR ELEVATIONS

AND SCHEDULE

A-521

A-551

EXISTING PLANTER

CONCRETE FOUNDATION

REF. STRUC.

CONCRETE SLAB -

REF. STRUCT.

JOIST BRG.

111' - 0"

FIN. FLOOR

100' - 0"

T.O. PARAPET

117' - 4"

22.7

A-501

A-501

A-501

SIM

FACE BRICK WALL TYPE 'E1'

REF. EXTERIOR ELEVATIONS

FOR BRICK COLOR TYPE

VAPOR BARRIER

GRANULAR FILL

PERIMETER INSULATION

CONCRETE FOUNDATION

REF. STRUC.

VARIES

CONCRETE SLAB -

REF. STRUCT.

Drawing Title

Approved: Associate Director

Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration Approved: Chief of Staff

Approved: Infection Control

Approved: Chief Engineer

Approved: Safety Officer

Approved: Chief, Police & Security

GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623…