Attachment 2 - Drawings 589-501 1-15.pdf
PDF 22 MB Posted
- Solicitation number
- 36C77624B0031
About this file
The provided document is Attachment 2 - Drawings 589-501 1-15.pdf, which contains technical drawings related to Solicitation Number 36C77624B0031 for the "589-501 Construction Outpatient Mental Health Addition (VA-24-00072549)" federal contract opportunity.
The drawings depict the architectural, civil, structural, mechanical, electrical, and plumbing plans for the outpatient mental health facility addition project, which is being procured by the Department of Veterans Affairs Technology Acquisition Center Austin. The drawings provide detailed specifications and design details for the construction of the facility. This attachment supplements the full solicitation package, which includes the Statement of Work, pricing templates, and other contractual requirements.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONCRETE,
CAST-IN-PLACE
GROUT
BRICK,
COMMON/FACE
CONCRETE
MASONRY UNIT
STONE,
CAST
ALUMINUM
ORNAMENTAL
METAL
STEEL AND
OTHER METALS
INSULATION,
LOOSE FILL OR
BLANKET
INSULATION,
RIGID BOARD
SHEET METAL
PLASTER,
GYPSUM OR
PORTLAND CEMENT
EARTH,
CRUSHED ROCK
GRAVEL
EARTHWORK,
COMPACTED
FILL
SAND
CMU
BOND BEAM
LINTEL
CMU, END
PLYWOOD
WOOD BLOCKING
OR SHIM
WOOD FRAMING,
CONTINUOUS
GLASS, ELEVATION
NAME
ELEVATION
101A
PLAN NORTH
ID
ID
NAME
NO
IDID
0 8' 16'4'C4
DRAWING BLOCK TITLE
1/8" = 1'-0"
NO
SHT
SIM
NO
SHT
SIM
NO
SHT
SIM
BUILDING SECTION IDENTIFICATION
SECTION NUMBER
SHEET NUMBER
WALL SECTION IDENTIFICATION
SECTION NUMBER
SHEET NUMBER
SHEET
ELEV_NO
Ref
R ef
Ref
R ef
EXTERIOR ELEVATION IDENTIFICATION
SHEET
RefEL
R ef
EL
RefEL
R ef
EL
INTERIOR ELEVATION IDENTIFICATION
ELEVATION NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
SHT
NO
SIM
DETAIL/CALLOUT IDENTIFICATION
DETAIL NUMBER
SHEET NUMBER
DRAWING BLOCK TITLE
VIEW NUMBER
VIEW SCALE
VIEW NAME
GRAPHIC SCALE
EXTERIOR ELEVATION IDENTIFICATION
ELEVATION NAME
ELEVATION
NORTH INDICATOR
PROJECT NORTH LINE
TRUE NORTH LINE
COLUMN LINE GRID INDICATOR
ID
GRID IDENTIFICATION
FLOOR PLAN REFERENCE INDICATORS
ROOM TAG
WINDOW TAG
DOOR TAG
PARTITION TAG
REVISION TAG
KEYNOTE TAG
SPOT ELEVATION
TAG
100'-0"
CL CENTER LINE
Abbreviation Term
1WAY one-way 2WAY two-way 3PLY three-ply 3WAY three-way 4WAY four-way
A A LABEL Class A door A/C air condition A/C UNIT air conditioning unit A/E architect/engineer AAP alarm annunciator panel AB anchor bolt ABBRV abbreviation ACC accessible ACOUS INSUL acoustical insulation ACOUS PNL acoustical panel ACS DR access door ACS FLR access floor ACS PNL access panel ACT acoustical ceiling tile ADA Americans with Disabilities Act AFF above finished floor AGGR aggregate AHJ authority having jurisdiction AHU air handling unit AIA American Institute of Architects ALM alarm ALNMT alignment ALT alternate ALT NO alternate number ALUM aluminum ANN annunciator ANOD anodize APC acoustical panel ceiling APPD approved APPROX approximate ARCH Architect ASKLR automatic sprinkler ASPH asphalt ATS automatic transfer switch AV audio visual
B B LABEL Class B door B PL base plate BAS building automation system BB baseboard BC bookcase BD board BDRY boundary BFF below finish floor BHMA Builder's Hardware
Manufacturer's Association BITUM bituminous BLKHD bulkhead BLT IN built-in BLW CLG below ceiling BN bullnose BRCG bracing BRDG bridging BRDG JST bridging joist BRG bearing BRG PL bearing plate BRZ bronze BTWN between BUR built-up roofing
C cont.
CER ceramic CF contractor furnished CF/CI contractor furnished/ contractor installed CF/OI contractor furnished/ owner installed CFE contractor furnished equipment CFLG counterflashing CFMF cold-formed metal framing CG corner guard CHFR chamfer CI cast iron CIP cast-in-place CIR circle CJ control joint CL center line CLDG cladding CLG ceiling CLG DIFF ceiling diffuser CLG GRL ceiling grille CLG HT ceiling height CLG REG ceiling register CLKJ calked joint CLR color CMPST composite CMPTR computer CMU concrete masonry unit CNR corner CNTOR contactor CNTR counter CO cleanout COL column COMM communication CONC concrete CONC FLR concrete floor CONC OPNG concrete opening CONSTR construction CONSULT consultant CONT continue COORD coordinate CORR corridor COV PL cover plate CP control panel CPT carpet CRCMF circumference CRT YD courtyard CS cast stone CSG casing CSI Construction Specifications
Institute CSK counter sunk CSMT casement CSTL cast steel CSWK casework CT ceramic tile CT STN cut stone CTB ceramic tile base CTF ceramic tile floor CTG coating CTR center CTRL control CU FT cubic feet CU IN cubic inch CU YD cubic yard CURT curtain
E E LABEL Class E door EA each EFS exterior finish system EGB exterior gypsum board EGSB exterior gypsum sheathing board EIFS exterior insulation and finish system EJ expansion joint EL elevation ELEC electric ELEV elevator ENTR entrance EOS edge of slab EPS expanded polystyrene board
(insulation) EQ equal EQUIP equipment ESCAL escalator EXST existing EXT exterior EXT GR exterior grade EXT LT exit light
F F BRK fire brick FAAP fire alarm annunciator panel FABL fire alarm bell FABX fire alarm box FACP fire alarm control panel FAR floor area ratio FAS BD fascia board FC BRK face brick FD floor drain FDC fire department connection FDCC fire department connection cabinet FDMPR fire damper FDR fire door FDTN foundation FDV fire department valve FE fire extinguisher FEC fire extinguisher cabinet FF finish face FF BATT foil backed batt insulation FF EL finish floor elevation FF&E furniture, fixture, and equipment FFA from floor above FFB from floor below FH fire hydrant FHC fire hose cabinet FHP full height partition
I IBC International Building Code ID identification ID NO identification number INFO information INSUL insulation INSUL PNL insulated metal panel INT interior
J JAN janitor JAN CLO janitor closet J-BOX junction box JS janitor's sink
K KIT kitchen KPL kickplate KWY keyway
L cont.
LNDSCP landscape LT light LT FLUOR fluorescent lighting LT GA light gage LTG lighting LVR louver LW PLAS lightweight plaster LWC lightweight concrete
M MACH RM machine room MATL material MAX maximum MC moisture content MD metal deck MECH mechanical MECH RM mechanical room MEMB membrane MEP mechanical, electrical, plumbing MEZZ mezzanine MFR manufacturer MIN minimum MIRR mirror MISC miscellaneous MLDG molding (moulding) MLWK millwork MOD modify MOD BIT modified bitumen MR moisture resistant MS mop sink MTL metal MVBL movable MWP membrane waterproofing
N N north NA not applicable NFC National Fire Code NFPA National Fire Protection
Association NIC not in contract NO number NOM nominal NP no paint NRC noise reduction coefficient NTS not to scale
O OA overall OC on center OCC occupy OD outside diameter OF/CI owner furnished/ contractor installed OFD overflow drain OF/OI owner furnished/owner installed OFS outside face of studs OH DR overhead (coiling) door OPNG opening ORD overflow roof drain OVFL overflow
P cont.
PLG piling PLYWD plywood PNL panel PRCST precast PREFIN prefinish PRKG parking PT paint PTN partition PVC polyvinyl chloride (plastic) PVF polyvinyl fluoride (plastic) PVG paving PWR power
S SAT suspended acoustical tile SATC suspended acoustical tile ceiling SB splash block SBS styrene butadien styrene SBSTR substrate SCHED schedule SCMU solid concrete masonry unit SCRN screen SDG siding SDMPR smoke damper SECT section SF square foot (feet) SHT MTL FLASH sheet metal (flashing) SHTHG sheathing SHV shelving SIM similar SJ slab construction joint SLNT sealant SMK smoke SND sanitary napkin dispenser SND INS sound insulation SP EL spot elevation SPEC specification SPKLR sprinkler SQ square SQ IN square inch SQ YD square yard
Q QT quarry tile QTB quarry tile base QTF quarry tile floor QTY quantity
R RB resilient base RB HK robe hook RBM reinforced brick masonry RC reinforced concrete RCP reflected ceiling plan RCPTN reception RD roof drain RDG INS rigid insulation, solid REBAR reinforcing steel bars REF reference REINF reinforce REQ require REQD required RESIL resilient REV revision RHR right hand reverse RL roof leader RLG railing RM room RO rough opening RSD rolling steel door RT right RTF rubber tile floor RTG rating RTU roof top unit RV roof vent RVL reveal
S cont.
SST stainless steel STC sound transmission class STD standard STL JST steel joist STL LNTL steel lintel STL PL steel plate STL RF DK steel roof deck STL TB steel tube STL TR steel truss STOR storage STRUCT structural STRUCT STL structural steel SUSP suspend SUSP CLG suspended ceiling SV sheet vinyl SYM symbol SYS system
T TD trench drain TE top elevation TEMP temporary TFF top of finish floor THK thickness THRU through TMPD tempered TRTD treated TS tube steel TYP typical
U UGND underground UL Underwriters Laboratories UNFIN unfinish UNO unless noted otherwise
V VAN vanity VAP PRF vapor proof VB vinyl base VCT vinyl composition tile VEST vestibule VFAT vinyl faced acoustical tile VNR veneer VR vapor retarder VRFY verify VTR vent through roof
W W CAB wall cabinets W/O without WB wood base WBL wood blocking WC water closet WC WL HNG water closet, wall hung WCLR water cooler WD wood WD LOUV wood louvers WDF wood door and frame WDP wood panelling WF wide flange WF BM beam, wide flange WFAB wall fabric WFR wood frame WFS wood furring strips WGL wired glass WPM waterproof membrane WSCT wainscot
X, Y, Z X BRACE cross brace X SECT cross section XBRA crossbracing XPS extruded polystyrene board
(insulation)
YD yard
Z modulus of section
D cont.
DIM dimension DIST distance DIV division DOC document DPTN demountable partition DR door DR CL door closer DR FR door frame DR OPNG door opening DRH door holder DRLV door louver DRST door stop DRSW door switch DW dishwasher DWG drawing
F cont.
FN fence FR fire rating FRMG framing FRP fiberglass reinforced plastic FRST GL frosted glass FRTW fire retardant treated wood FT feet FTG footing FW fire wall FWRK formwork
G GALV galvanized GC general contractor GFRC glass-fiber-reinforced concrete GFRG glass-fiber-reinforced gypsum GFRP glass-fiber-reinforced plaster GFRP glass-fiber-reinforced plastic GL glass GL BLK glass block GLU LAM glued laminated wood GLZ glazing GLZ CMU glazed concrete masonry unit GPC gypsum plaster ceiling GR BM grade beam GR FL ground floor GR LN grade line GSB gypsum sheathing board GUT gutter GWT glazed wall tile GYM gymnasium GYP gypsum GYP BD gypsum board GYP PLAS gypsum plaster
H HB hose bibb HCP handicapped HCWD hollow core wood door HM hollow metal HMD hollow metal door HMDF hollow metal door and frame HMF hollow metal frame HNDRL handrail HORIZ horizontal HS hand sink HT height HVY heavy HYD hydrant
C C CONC cast concrete C LABEL Class C door CAB cabinet CAC ceiling attenuation class CATW catwalk CBB cementitious (backer) board CEM cement CEM FIN cement finish CEM PLAS cement plaster CEM PLAS CLGcement plaster ceiling
D D LABEL Class D door DBL double DBL ACT DR double acting door DBL GLZ double glaze DEMO demolition DEPT department DET detail DF drinking fountain DF WL MTDdrinking fountain, wall mounted DIA diameter
F FIN finish FIXT fixture FLG flooring FLR floor FLR FIN floor finish FLR PL floor plate FLR SK floor sink
L LAM laminate LAV lavatory LBS pounds LED light emitting diode LF linear feet (foot) LF INS loose fill insulation LKR RM locker room LL low level
P PAR parapet PAT pattern PB pull box PBD particleboard PCC precast concrete PCP portland cement plaster PERF perforated PERIM perimeter PGBD pegboard PIL pilaster PL property line PL GL plate glass PLAM plastic laminate PLAS plaster PLBG plumbing
OWNER:
Colmery-O'Neil VA Medical Center 2200 Gage Boulevard Topeka, Kansas P: (913) 946-1140 C: Timothy Parison Sr., Contracting Officer E: timothy.parison@va.gov
ARCHITECT:
GLMV Architecture, Inc.
1525 E. Douglas Wichita, KS 67211 P: (316) 265-9367 C: Fred Britain, AIA, Project Manager E: fred.britain@glmv.com
MECHANICAL / ELECTRICAL / PLUMBING:
Professional Engineering Consultants 623 Massachusetts Street, Suite 200 Topeka, KS 66044 P: (785) 842-6464 C: Tracy Dible, PE E: tracy.dible@pec1.com
INDUSTRIAL HYGIENIST
Terracon 72 Pointe Circle Greenville, SC 29615 P: (864) 292-2901 C: Jeffrey Gurrie, CIH E: jeff.gurrie@terracon.com
ARCHITECT / ENGINEEROWNER
CONSULTANTS
ARCHITECT OF RECORD:
Atriax, pllc 703 Main Avenue SW Hickory, NC 28602 (PO Box 1629 Hickory, NC 28603) P: (828) 315-9962 C: Bob Sinclair E: bob.sinclair@atriaxgroup.com
1. CONTRACTOR WILL VERIFY AND FAMILIARIZE THEMSELF WITH ALL EXISTING CONDITIONS PRIOR TO PLACING BID.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE OF ALL
DISCREPANCIES IF ANY, FOUND PRIOR TO PLACEMENT OF ANY COMPONENTS.
3. THE CONTRACTOR WILL TAKE ALL NECESSARY PRECAUTIONS INCLUDING THE BUILDING AND MAINTENANCE OF DUST
TIGHT PARTITIONS, DAILY VACUUMING, SWEEPING, AND PROVISION OF CLEAN FLOOR MATS AT THE PROJECT ENTRANCES, TO PREVENT THE INFILTRATION OF DIRT AND DUST FROM THE CONSTRUCTION AREAS INTO THE OWNER
OCCUPIED AREAS.
4. IF THE PROJECT AREA INCLUDES EXISTING EQUIPMENT, SURFACES, FINISHES, MATERIALS, ETC., NOT TO BE REMOVED, THE CONTRACTOR MUST PROTECT THIS EQUIPMENT FROM DUST, DEBRIS, DAMAGE, ETC. THE CONTRACTOR MUST ALSO CLEAN THESE ITEMS/SURFACES TO THE ORIGINAL CONDITION FOUND AT THE START OF THE PROJECT PRIOR TO FINAL
INSPECTION.
5. PATCH ALL FINISHES WHERE DISTURBED BY THE WORK AND WHERE UNFINISHED SURFACES HAVE BEEN EXPOSED BY DEMOLITION. PATCHING MUST MATCH ADJACENT MATERIALS, COLORS, AND FINISHES. WALL SURFACES THAT ARE PATCHED SHALL HAVE THE FINISHES (PAINT, VINYL WALL COVERING, ETC.) REPLACED FROM CORNER TO CORNER AND
FLOOR TO CEILING.
6. UNLESS OTHERWISE INDICATED, FINISH ALL NEW FRAMES AND PARTITIONS TO MATCH SURROUNDING. NEW HOLLOW METAL DOORS SHALL BE PAINTED SAME COLOR AS FRAMES. EXISTING PARTITIONS RECEIVING NEW DOOR FRAMES THAT HAVE VINYL WALL COVERING (VWC) SHALL HAVE THE VWC COMPLETELY REMOVED AND REPLACED WITH NEW VWC OF
MATCHING TEXTURE AND COLOR.
7. PAINT ALL EXPOSED NEW AND EXISTING PIPING, CONDUIT, WIRE MOLD, ELECTRICAL PANELS, ACCESS PANELS, ETC., TO
MATCH WALL FINISH UNLESS OTHERWISE NOTED.
8. WHENEVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED OTHERWISE. AFTER REMOVAL; FLOORS, WALLS, AND CEILINGS SHALL BE FINISHED TO MATCH ADJOINING SURFACES.
9. UTILITY WORK THAT WILL REQUIRE A SHUTDOWN OF EXISTING SERVICE WILL BE DONE AT TIMES OTHER THAN NORMAL WORKING HOURS AT NO ADDITIONAL COST TO THE GOVERNMENT. WORK MUST BE SCHEDULED WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE.
10. COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS TO ELIMINATE CONFLICTS AND/OR INTERFERENCES. THE CONTRACTOR SHALL PROVIDE ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM.
11. DRAWINGS ARE DIAGRAMMATIC AND SHOW ONLY THE GENERAL ARRANGEMENT OF EACH SYSTEM. BECAUSE OF SMALL SCALE OF DRAWINGS IT IS NOT POSSIBLE TO SHOW OR INDICATE ALL BRANCHES, OFFSETS, FITTINGS, BOXES, AND ACCESSORIES WHICH MAY BE REQUIRED. CONTRACTOR MUST CAREFULLY INVESTIGATE STRUCTURAL AND FINISH CONDITIONS AFFECTING ALL WORK, FURNISHING SUCH FITTINGS, TRAPS, VALVES, BOXES, ACCESSORIES, ETC., AS MAY
BE REQUIRED.
12. LOCATIONS OF NEW EQUIPMENT, PIPING, AND ASSOCIATED ITEMS SHOWN ON THE DRAWINGS ARE SCHEMATIC ONLY.
THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION AND ELEVATION FOR ALL WORK, INCLUDING CONNECTIONS TO EXISTING WORK. ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE AND
FUNCTIONAL SYSTEM SHALL BE PROVIDED AT NO ADDITIONAL COST.
13. ALL EXISTING DUCTWORK, ELECTRICAL OR MECHANICAL PIPING, CABLE TRAYS, ETC., IS NOT NECESSARILY SHOWN ON THE DRAWINGS. BEFORE CONTRACTOR PLACES A BID IT IS IMPERATIVE THEY VISIT THE JOBSITE AND FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. IT WILL BE PART OF THE CONTRACTOR'S RESPONSIBILITY AND THE CONTRACTOR WILL BEAR THE COST TO ENGINEER AND RELOCATE ANY EXISTING OBSTACLES WHICH WILL INTERFERE WITH THE CONTRACTOR'S ABILITY TO INSTALL ALL NEW OR RELOCATED WORK IN THIS PROJECT.
14. CONTRACTOR SHALL NOT INSTALL CONDUIT, PIPING, LIGHTING, OR OTHER OBSTRUCTIONS UNDER OR ADJACENT TO HVAC EQUIPMENT THAT WILL ELIMINATE OR OBSTRUCT ACCESS TO COILS, MOTORS, VALVES, SWITCHES, PANELS, ETC.
15. BEFORE THE CONTRACTOR BEGINS WORK HE SHALL RECORD ANY EXISTING SYSTEM INFORMATION SUCH AS TEMPERATURE, FLOW RATE, PRESSURE, CURRENT, VOLTAGE, OR ANY OTHER INFORMATION NECESSARY FOR HIM TO RETURN THE AFFECTED SYSTEM TO ORIGINAL OPERATING CONDITION. UNLESS NOTED OTHERWISE IT IS ASSUMED THAT ALL SYSTEMS (HVAC, ELECTRICAL, PLUMBING, ETC.) ARE WORKING PROPERLY IN EVERY MANNER AT THE BEGINNING OF THE PROJECT. THE CONTRACTOR'S RECORDED MEASUREMENTS MUST BE SUBMITTED TO THE CONTRACTING OFFICER'S REPRESENTATIVE FOR REVIEW AND ACCEPTANCE BEFORE ANY DEMOLITION OR OTHER RELATED WORK CAN PROCEED.
16. THE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTAINING ALL EXISTING ACCESS DOORS TO CONSTRUCTION AREAS, EXISTING MECHANICAL AND ELECTRICAL AREAS, ASSIGNED STORAGE AREAS, EQUIPMENT ACCESS AREAS, ETC. DOORS MUST BE RESTORED TO THE CONDITION ENCOUNTERED AT BEGINNING OF PROJECT. THIS INCLUDES DOOR
REPLACEMENT, HARDWARE REPLACEMENT, HARDWARE REPAIR, DOOR REPAIR, ETC.
17. NOTE: IF THERE IS ANY WORK TO BE DONE ON EXISTING ROOFS, SUCH AS ROOF PENETRATIONS OR STANDS, OR ANYTHING THAT DAMAGES THE INTEGRITY OF THE ROOF, THIS WORK MUST BE DONE BY A CONTRACTOR LICENSED BY THE ROOFING MEMBRANE MANUFACTURER. HE MUST BE APPROVED BY THE MEMBRANE MANUFACTURER SO AS TO NOT
VOID OR INTERRUPT EXISTING SINGLE PLY MEMBRANE ROOF WARRANTIES.
18. CONTRACTOR MUST PROVIDE HIS OWN EQUIPMENT FOR MOVING OF MATERIALS, EQUIPMENT AND TRASH. THIS INCLUDES CARTS FOR REMOVAL OF DEMOLITION MATERIALS, PALLET JACKS FOR EQUIPMENT MOVING, TWO OR FOUR WHEEL CARTS FOR EQUIPMENT TRANSFER, ETC. CONTRACTOR MAY NOT BORROW VA OWNED EQUIPMENT FOR THIS
PURPOSE.
19. IF ASBESTOS INSULATION IS REMOVED ON THIS PROJECT ALL PIPING AND OTHER MECHANICAL ITEMS THAT HAD THE ASBESTOS INSULATION REMOVED MUST BE REINSULATED WITH MATERIALS ACCORDING TO THE SPECIFICATIONS.
20. SEVERE NOISE PRODUCING WORK WILL NOT BE ALLOWED DURING NORMAL WORKING HOURS AND MUST BE SCHEDULED WITH THE CONTRACTING OFFICER'S REPRESENTATIVE FOR OTHER TIMES. THIS INCLUDES JACKHAMMERING CONCRETE, SAWCUTTING CONCRETE, REPETITIVE HAMMER DRILLING OF CONCRETE, ETC.
21. THE VA DOES NOT PROVIDE TELEPHONE SERVICE OR A TELEPHONE FOR THE CONTRACTORS USE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COVER THE COSTS OF THE INSTALLATION OF A TEMPORARY LAND LINE PHONE. THE
CONTRACTOR SHALL CONTACT THE TELEPHONE COMPANY TO HAVE THIS PHONE INSTALLED.
22. ALL CONTRACTOR’S PERSONNEL WHO PLAN TO WORK ON SITE MUST RECEIVE AN ID BADGE THROUGH THE VA’S PIV (PERSONAL IDENTITY VERIFICATION) PROGRAM. THIS REQUIRES HAVING FINGERPRINTS TAKEN AND A BACKGROUND
CHECK DONE BEFORE THE BADGE CAN BE ISSUED.
23. WATER OR LIQUIDS MUST NOT BE ALLOWED TO COME INTO CONTACT WITH NEW OR EXISTING DRYWALL FROM CONSTRUCTION RELATED ACTIVITIES. REMOVE AND REPLACE ANY DRYWALL THAT HAS COME INTO CONTACT WITH
WATER OR OTHER LIQUIDS.
24. LIVE ELECTRICAL CIRCUITS ARE BURIED WITHIN THE CONCRETE FLOOR SLABS AND THERE IS NO RECORD OF THE EXACT LOCATIONS. THE CONTRACTOR SHALL X-RAY THE FLOOR WHEREVER THE CONTRACTOR PLANS ON DRILLING THROUGH THE CONCRETE FLOOR SLABS. IT WILL BE THE CONTRACTOR’S RESPONSIBILITY TO IMMEDIATELY REPAIR ANY CIRCUIT
THAT HAS BEEN CUT OR DAMAGED.
25. WHEN THE CONSTRUCTION REQUIRES THAT EXISTING EXITS FROM THE BUILDING BE BLOCKED OR CLOSED THE CONTRACTOR MUST INSTALL BARRIERS IN FRONT OF THE EXIT TO BLOCK PASSAGE, INSTALL SIGNAGE ON THE BARRIERS OR DOOR STATING THAT THE EXIT IS CLOSED AND COVER THE LIGHTED EXIT SIGN FOR THIS EXIT. THESE MUST ALL BE
REMOVED WHEN THE EXIT IS REOPENED.
26. CONTRACTOR SHALL PROVIDE BOXES, CONDUIT, WIRE, AND RECONNECTIONS AS REQUIRED TO RECONNECT ANY AND ALL EXISTING LIGHT FIXTURES, RECEPTACLES, OR DEVICES REMAINING IN USE. REMOVAL OF ANY ELECTRICAL
EQUIPMENT SHALL NOT AFFECT THE OPERATION OF EQUIPMENT REMAINING IN USE.
27. A GREEN GROUND SHALL BE RUN WITH ALL FEEDERS AND WITH ALL CIRCUITS TO RECEPTACLES, MOTORS, FIXED
EQUIPMENT, AND APPLIANCES.
28. PANELBOARDS AND CIRCUIT BREAKERS SHALL HAVE THE FOLLOWING MINIMUM INTERRUPTING RATINGS:120/208 - 22,000
AMPERES SYMMETRICAL, 277/480 - 14,000 AMPERES SYMMETRICAL
29. CONTINUITY OF ALL SERVICES TO AND FROM THE FACILITIES IN THE EXISTING BUILDING SHALL BE MAINTAINED WITHOUT INTERRUPTION, EXCEPT FOR SUCH PERIODS OF TIME WHICH THE V.A. MAY DESIGNATE. IF TEMPORARY CONNECTIONS, ETC. ARE NECESSARY TO ASSURE THE CONTINUITY OF SERVICE, THEY SHALL BE FURNISHED WITHOUT ADDITIONAL
CHARGE TO THE V.A. AND SHALL BE REMOVED WHEN NO LONGER NECESSARY.
30. ALL INSTALLATIONS AND EQUIPMENT SHALL FOLLOW THE GUIDELINES ESTABLISHED BY THE CURRENT NATIONAL
ELECTRIC CODE
31. ALL EXISTING CONDUIT AND WIRING MADE ABANDONED BY THIS PROJECT OR FOUND TO BE ABANDONED DURING
DEMOLITION SHALL BE REMOVED.
32. COORDINATE THE PROVISION AND INSTALLATION OF ALL CONTROL WIRING FOR MECHANICAL EQUIPMENT WITH THE
GENERAL CONTRACTOR AND MECHANICAL CONTRACTOR.
33. FOR SAFETY PURPOSES THE CONTRACTOR WILL NOT WORK ON ANY ELECTRICAL EQUIPMENT HOT. ALL SHUTDOWNS
WILL BE SCHEDULED IN ADVANCE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
34. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL CONDUITS IN WALLS SHALL
BE GROUTED OR SEALED INTO OPENINGS.
35. FOR DOORS BEING REPLACED AND WALLS WITHIN A CONSTRUCTION AREA: CAREFULLY REMOVE SIGNAGE, ROOM NUMBERS, ARTWORK, ETC., AND STORE IN A PROTECTIVE BOX FOR REINSTALLATION AT COMPLETION OF AREA. ANY DAMAGED SIGNAGE, ARTWORK, ETC., SHALL BE REPLACED WITH NEW. VA INTERIOR DESIGNER AND COR SHALL IDENTIFY
LOCATIONS FOR REINSTALLATION.
36. USE OF EQUIPMENT AND TOOLS FOR WORK THAT TRANSMIT VIBRATIONS AND CREATE NOISES >80DB REQUIRE VA COR APPROVAL DURING BUSINESS HOURS. DATES AND DURATIONS SHALL BE SUBMITTED 20 WORKING DAYS BEFORE WORK IS TO BE COMPLETED. VA COR SHALL APPROVE DATES AND DURATIONS SUBMITTED BY GC BEFORE WORK IS TO BEGIN. IF APPROVED, WORK DURING BUSINESS HOURS SHALL BE 30 MINUTES OF WORK FOLLOWED BY 30 MINUTES OF QUIET TIME
(DEFINED AS <80 DB AND VIBRATION FREE).
37. NO UTILITY SERVICE SUCH AS WATER, GAS, STEAM, SEWERS OR ELECTRICITY, OR FIRE PROTECTION SYSTEMS AND COMMUNICATIONS SYSTEMS MAY BE INTERRUPTED WITHOUT APPROVED TASK WORK PLAN AND PRIOR APPROVAL OF COR. ELECTRICAL WORK SHALL BE ACCOMPLISHED WITH ALL AFFECTED CIRCUITS OR EQUIPMENT DE-ENERGIZED. WHEN AN ELECTRICAL OUTAGE CANNOT BE ACCOMPLISHED, WORK ON ANY ENERGIZED CIRCUITS OR EQUIPMENT SHALL NOT COMMENCE WITHOUT A DETAILED WORK PLAN, THE MEDICAL CENTER DIRECTOR’S PRIOR KNOWLEDGE AND WRITTEN APPROVAL. CONTRACTOR SHALL SUBMIT A INDIVIDUAL TASK WORK PLAN TO INTERRUPT ANY SUCH SERVICES TO COR, IN WRITING, 20 DAYS IN ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE, EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. CONTRACTOR WILL BE ADVISED (IN WRITING) OF APPROVAL OF REQUEST, BEFORE THE UTILITY INTERRUPTION NOTIFICATION SHALL BE POSTED BY CONTRACTOR, OR OF WHICH OTHER DATE AND/OR TIME SUCH INTERRUPTION WILL CAUSE LEAST INCONVENIENCE TO OPERATIONS OF MEDICAL CENTER.
INTERRUPTION TIME APPROVED BY MEDICAL CENTER MAY OCCUR AT OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. THE UTILITY INTERRUPTION NOTIFICATION MUST BE POSTED 11 FEDERAL WORKDAYS PRIOR TO WHEN THE
UTILITY INTERRUPTION WORK CAN BEGIN.
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans Health
Administration
Medical Center Director: Date:
Associate Medical Center Director: Date:
Engineering M&O Foreman: Date:
Chief Engineering Service: Date:
Boiler Plant Foreman: Date:
Safety Manager: Date:
Industrial Hygenist: Date:
Infection Control Nurse: Date:
Energy Manager: Date:
Approved: Date:
Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044
Phone: 785-842-6464 www.pec1.com
Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
ISSUED FOR BID
/2
/2
:5
:1
P
M A u to d e s k D o c s /1
.2
A tr ia x T o p e k a
V A
M e n ta l H e a lt h C lin ic
(M o d
.2
A
A tr ia x
T o p e k a V
A M e n ta l H e a lt h C lin ic
(M O
D
V
.r v t
G-001
COVER SHEET Outpatient Mental Health Clinic
Colmery-O'Neil VAMC Topeka, KS
589-501
03/29/24 FAB LD
ARCHITECTURAL LEGEND MISC. ARCHITECTURAL SYMBOLS SHEET INDEX
SITE LOCATION
DEPARTMENT OF VETERANS AFFAIRS
GENERAL NOTES
ARCHITECTURAL ABBREVIATIONS
COLMERY-O'NEIL VA MEDICAL CENTER - TOPEKA, KANSAS
PROJECT NO. 589-501
OUTPATIENT MENTAL HEALTH CLINIC
DIRECTORY
SHEET
NUMBER SHEET NAME
01 [G] GENERAL
G-001 COVER SHEET
G-002 CODE FLOOR PLAN - BASEMENT
G-003 CODE FLOOR PLAN - FIRST FLOOR
05 [C] CIVIL
V-101 EXISTING CONDITIONS
CD101 DEMO PLAN
CS101 SITE PLAN
CG101 GRADING AND DRAINAGE PLAN
CU101 SITE UTILITY PLAN
C-501 SITE DETAILS
C-502 SITE DETAILS
C-503 SITE DETAILS
06 [L] LANDSCAPE
LP101 LANDSCAPE PLAN
07 [S] STRUCTURAL
S-001 GENERAL NOTES
S-002 GENERAL NOTES AND INSPECTION TABLES
S-101 FOUNDATION PLAN
S-121 ROOF FRAMING PLAN
S-301 COLUMN SCHEDULE
S-302 BRACE FRAME SCHEDULE & DETAILS
S-501 TYPICAL FOUNDATION DETAILS
S-502 FOUNDATION DETAILS
S-511 TYPICAL FRAMING DETAILS
S-512 FRAMING DETAILS
S-513 FRAMING DETAILS
S-601 SCHEDULES
S-602 SCHEDULES
08 [A] ARCHITECTURAL
AD101 OVERALL DEMOLITION PLAN
AD102 DEMOLITION PLAN - FIRST FLOOR
A-101 OVERALL IMPROVEMENT PLANS
A-102 IMPROVEMENT PLAN - FIRST FLOOR
A-103 DIMENSION PLAN - FIRST FLOOR
A-111 OVERALL REFLECTED CEILING PLANS
A-112 REFLECTED CEILING PLANS - FIRST FLOOR
A-121 PARTIAL ROOF PLAN
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-311 WALL SECTIONS
A-401 ENLARGED PLANS
A-501 EXTERIOR DETAILS
A-502 INTERIOR DETAILS
A-511 CEILING DETAILS
A-521 ROOF DETAILS
A-522 ROOF DETAILS
A-551 STOREFRONT AND CURTAIN WALL DETAILS
A-552 DOOR DETAILS
A-601 WALL TYPES
A-611 DOOR SCHEDULE
A-612 STOREFRONT AND CURTAIN WALL SCHEDULE
09 [I] INTERIORS
I-001 TYPICAL MOUNTING HEIGHTS
I-101 OVERALL FINISH PLANS
I-103 FINISH PLAN - FIRST FLOOR
I-122 SIGNAGE AND SPECIALTIES PLAN - FIRST FLOOR
I-201 INTERIOR DESIGN ELEVATIONS AND ENLARGED PLANS
I-501 CASEWORK SECTIONS AND INTERIOR DETAILS
I-521 SIGNAGE DETAILS
I-522 SIGNAGE DETAILS
I-601 FINISH SCHEDULE
IF103 FURNISHING PLAN - FIRST FLOOR
10 [F] FIRE PROTECTION
FP100 OVERALL FIRE PROTECTION PLANS
PROJECT LOCATION
SHEET
NUMBER SHEET NAME
12 [P] PLUMBING
PP000 PLUMBING NOTES AND SYMBOLS
PD100 OVERALL PLUMBING DEMOLITION PLAN
PD101 PLUMBING DEMOLITION PLAN - BASEMENT
PD102 PLUMBING DEMOLITION PLAN - FIRST FLOOR
PL100 OVERALL PLUMBING PLANS
PL101 PLUMBING PLAN - BASEMENT
PL102 PLUMBING PLAN - FIRST FLOOR
PP500 PLUMBING SCHEDULES & DETAILS
14 [M] MECHANICAL
MM000 MECHANICAL COVER SHEET
MM001 MECHANICAL COVER SHEET
MD100 MECHANICAL DEMOLITION PLAN - OVERALL
MD101 MECHANICAL DEMOLITION PLAN - BASEMENT
MD102 MECHANICAL DEMOLITION PLAN - FIRST FLOOR
MH100 OVERALL HVAC PLANS
MH101 HVAC PLAN - BASEMENT
MH102 HVAC MV & RA PLAN - FIRST FLOOR
MH103 HVAC SA & EA PLAN - FIRST FLOOR
MH200 MECHANICAL ROOF PLAN
MM500 MECHANICAL DETAILS
MM501 MECHANICAL DETAILS
MM502 MECHANICAL DETAILS
MM503 MECHANICAL CONTROL DETAILS
MM504 MECHANICAL CONTROL DETAILS
MM600 MECHANICAL SCHEDULES
MM601 MECHANICAL SCHEDULES
MP100 OVERALL HYDRONIC PLANS
MP101 HYDRONIC PLAN - BASEMENT
MP102 HYDRONIC PLAN - BASEMENT
MP103 HYDRONIC PLAN - FIRST FLOOR
15 [E] ELECTRICAL
E-001 ELECTRICAL NOTES AND SYMBOLS
ED101 ELECTRICAL DEMOLITION PLAN - BASEMENT
ED110 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR
OVERALL
ED111 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR
EG301 LIGHTNING PROTECTION ROOF PLAN
EG501 LIGHTNING PROTECTION DETAILS
EL110 LIGHTNING PLAN - FIRST FLOOR OVERALL
EL111 LIGHTNING PLAN - FIRST FLOOR ADDITION
EL501 LIGHTNING DETAILS
EP101 POWER PLAN - BASEMENT
EP110 POWER PLAN - FIRST FLOOR OVERALL
EP111 POWER PLAN - FIRST FLOOR ADDITION
EP211 EQUIPMENT PLAN - FIRST FLOOR ADDITION
EP220 EQUIPMENT PLAN - ROOF
EP501 POWER DETAILS
EP601 ELECTRICAL ONE-LINE DIAGRAMS
EP701 ELECTRICAL SCHEDULES
ES100 ELECTRICAL SITE PLAN
ET101 TELECOMMUNICATIONS PLAN - BASEMENT
ET111 TELECOMMUNICATIONS PLAN - FIRST FLOOR ADDITION
ET211 ENLARGED TELECOMMUNICATIONS - IT D107
ET501 TELECOMMUNICATIONS DETAILS
ET502 TELECOMMUNICATIONS DETAILS
EY101 SYSTEMS PLAN - BASEMENT
EY110 SYSTEMS PLAN - FIRST FLOOR OVERALL
EY111 SYSTEMS PLAN - FIRST FLOOR ADDITION
EY501 SYSTEMS DETAILS
EY502 SYSTEMS SCHEDULE
SHEET
NUMBER SHEET NAME
Revisions: Date:
COMMON PATH OF EGRESS = 106'-8"
MAX = 100'-0" (EXIST. NON-COMPLIANT)
FEC
FEC
FACP
NEUROPSYCH
A016
NEUROPSYCH
A017 IT
A018
P. TLT.
A019
S. TLT.
A020
STAIR
A0-S1
STOR
A002WKRM
A003
OFFICE
A004
GROUP ROOM
A005
OFFICE
A006
OFFICE
A007
PT RM
A009
PT RM
A008
PT RM
A011
PT RM
A012
ELEC
A027
ELEC
A026
HALL
A030
FILE STORAGE
A013A
MECH (N.I.C.)
A013B
ENERGY MGMT
(N.I.C.)
A013C
HALL
(N.I.C)
A013
MECH (N.I.C.)
A014
HALL (N.I.C.)
A015A
ELEC (N.I.C.)
A015
STAIR
A0-S4
CORRIDOR
0CDR1
STOR (N.I.C.)
A023
HSK N.I.C.
A022
FE
A025
HALL
A028
STOR
A029
ELEV #4
A0-E4
ELEV #5
A0-E5
ELEV #6
A0-E6
STAIR
B0-S2
STAIR
C0-S3
CRAWL SPACE CRAWL SPACE
UNEXCAVATED
EXIT ACCESS - RE: G-003 FOR
CONTINUATION AND LENGTH
E N
D O
F C
O M
M O
N
P A
T H
O F
E G
R E
S S
CODE PLAN LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER RATING 2-A
FIRE DOOR ASSEMBLY RATINGFR
FACP
FS
FIRE ALARM STATION,
MANUAL PULL
FIRE ALARM CONTROL PANEL
FAAP FIRE ALARM ANNUNCIATOR PANEL
EXIT SIGN,
CEILING MOUNTED
WITH DIRECTIONAL ARROW
FEC
FIRE DEPARTMENT CONNECTION
TWO-WAY SIAMESE
2-HOUR FIRE BARRIER
COMMON PATH OF EGRESS TRAVEL
AND/OR EXIT ACCESS TRAVEL DISTANCE
Clear exit width provided Capacity factor per IBC Sect. 1005.3.2 Required exit capacity Occupant load at exit
REQUIRED EXIT WITH OCCUPANT LOADOccupant load served
EGRESS DOOR TAG
40" 0.2
CODE ANALYSIS
GOVERNING REGULATIONS:
CODES UTILIZED EDITION
NFPA 101 LIFE SAFETY CODE 2018
NFPA 1 FIRE CODE 2018
NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2019
NFPA 70 NATIONAL ELECTRIC CODE 2020
NFPA 72 NATIONAL FIRE ALARM AND 2019
SIGNALING CODE
NFPA 90A INSTALLATION OF AIR-CONDITIONING 2021
AND VENTILATING SYSTEMS
NFPA 110 EMERGENCY AND STANDBY 2019
POWER SYSTEMS
NFPA 780 LIGHTING PROTECTION 2020
OCCUPATIONAL HEALTH AND SAFETY ADMINISTRATION (OSHA) STANDARDS
INTERNATIONAL PLUMBING CODE 2015
ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS
VA BARRIER FREE DESIGN GUIDE (PG-18-13)
VA DESIGN MANUALS - FROM THE VA TECHNICAL INFORMATION LIBRARY (TIL)
JURISDICTION
DEPARTMENT OF VERTERANS AFFAIRS (VA)
JOINT COMMISSION ON THE ACCREDITATION OF HEALTHCARE ORGANIZATIONS (JCAHO)
US DEPARTMENT OF HEALTH AND HUMAN SERVICES
USE AND OCCUPANCY:
OCCUPANCY CLASSIFICATION SECTION
EXISTING BUSINESS OCCUPANCY (REMODELED AREA) 6.1.11
NEW BUSINESS OCCUPANCY (ADDITION)
GENERAL BUILDING HEIGHTS AND AREAS:
BUILDING HEIGHT ALLOWABLE(ft) ACTUAL(ft) IBC TABLE 504.3
EXISTING: TYPE I (332) UNLIMITED 54 FT, 4 STORIES
NEW: TYPE 1 (322) UNLIMITED 10 FT, 1 STORY
NEW: TYPE II (000) 75 FT, 4 STORIES 18 FT, 1 STORY
BUILDING AREA ALLOWABLE(sf) ACTUAL(sf) IBC TABLE 506.2
EXISTING: TYPE I (332) UNLIMITED 32,407 SF
NEW: TYPE I (332) UNLIMITED 512 SF
TYPE II (000) 92,000 SF 9,083 SF
TYPE OF CONSTRUCTION:
CONSTRUCTION CLASSIFICATION NFPA 220
EXISTING: I(332) SPRINKLERED
NEW: II(000)* SPRINKLERED, NFPA 5000 - TABLE 7.2.1.1
*2-HOUR FIRE BARRIER WALL BETWEEN DIFFERENT CONSTRUCTION TYPES PER 8.2.1.3(1).
STRUCTURE FIRE RATING (HOURS): REQ'D I(322) EXISTING I(332)* REQ'D II(000) NEW II(000)
EXTERIOR BEARING WALLS 3 N/A 0 0
COLUMNS, BEAMS, GIRDERS 3 3 0 0
FLOOR/CEILING ASSEMBLIES 2 3 0 0
ROOF/CEILING ASSEMBLIES 1.5 3 0 0
INT NON-BEARING ASSEMBLIES 0 0 0 0
EXT NON-BEARING ASSEMBLIES 0 0 0 0
*INFORMATION ON EXISTING STRUCTURAL DESIGN AND CONCRETE TAKEN FROM LIFE-SAFETY DRAWINGS
DATED 05/18/2015
FIRE AND SMOKE PROTECTION:
FIRE BARRIERS SECTION
EXITS 1 HOUR (CONNECTS 3 OR FEWER STORIES) 7.1.3.2.1 (1)
2 HOUR PROVIDED TO MAINTAIN CONTINUITY W/ EXISTING
SMOKE BARRIERS SECTION
SUBDIVISION OF BUILDING SPACE - NOT REQUIRED 38.3.7
(SMOKE COMPARTMENT) 39.3.7
PENETRATIONS SECTION
THROUGH FIRE-RESISTANCE RATED ASEMBLIES 8.3.4
FIRE-RESISTANT JOINT SYSTEMS SECTION
AT FIRE-RESISTANCE RATED ASSEMBLIES 8.3.5
OPENING PROTECTIVES FIRE-RESISTANCE RATING (HR) SECTION
FIRE DOOR ASSEMBLIES FIRE BARRIER (2HR) = 90 MIN. TABLE 8.3.3.2.2
FIRE WINDOW ASSEMBLIES FIRE BARRIER (2HR) = NP TABLE 8.3.3.2.2
DOOR VISION PANEL MAX SIZE FIRE BARRIER (2HR) = MAX. SIZE TESTED TABLE 8.3.3.2.2
MIN. SIDELIGHT/TRANSOM FIRE BARRIER (2HR) = NP TABLE 8.3.3.2.2
INTERIOR FINISHES:
INTERIOR WALL AND CEILING FINISH REQUIREMENTS
OCCUPANCY CONDITION CLASS SECTION
BUSINESS INT. WALL AND CEILING A OR B 38.3.3.2.1
IN EXITS AND EXIT ACCESS CORRIDORS
INT. WALL AND CEILING (OTHER AREAS) A, B, OR C 38.3.3.2.2
FLOOR FINISH CLASS I OR II 38.3.3.3.2
NO REQ. 39.3.3.3
FIRE PROTECTION SYSTEMS:
AUTOMATIC SPRINKLER SYSTEMS
AUTOMATIC SPRINKLER SYSTEM PROVIDED THROUGHOUT
PORTABLE FIRE EXTINGUISHERS NFPA 10
FIRE EXTINGUISHERS FOR CLASS 'A' FIRE HAZARDS - LIGHT HAZARD OCCUPANCY
EXTINGHISHER RATING: TABLE 6.2.1.1
MINIMUM RATING: 2-A
MAX. FLOOR AREA / UNIT OF 'A': 3000 SF
MAX. FLOOR AREA / EXTINGUISHER: 11,250 SF
MAX. TRAVEL DIST. TO EXTINGUISHER: 75 FT
FIRE ALARM AND DETECTION SYSTEMS
AUTOMATIC ACTIVATION WITH SPRINKLER SYSTEM, SMOKE DETECTORS AND DUCT DETECTORS
MANUAL ACTIVATION WITH PULL STATIONS
MEANS OF EGRESS:
OCCUPANT LOAD TABLE 7.3.1.2
LOWER LEVEL:
BUSINESS: 48 OCCUPANTS(150 SF GROSS)
BASEMENT OCCUPANT LOAD 48 OCCUPANTS
FIRST FLOOR:
BUSINESS 187 OCCUPANTS (150 SF GROSS)
COLLABORATION OCCUPANCY 9 OCCUPANTS (30 SF GROSS)
ASSEMBLY OCCUPANCY 109 OCCUPANTS (15 SF GROSS)
FIRST FLOOR OCCUPANT LOAD 434 OCCUPANTS
COURTYARD (ASSEMBLY): 140 OCCUPANTS (15SF GROSS)
EGRESS WIDTH TABLE 7.3.3.1
EGRESS WIDTH PER OCCUPANT SERVED: 0.2 LEVEL COMPONENTS AND RAMPS
0.3 STAIRWAYS
COMMON PATH
OF EGRESS TRAVEL ALLOWABLE (FT) ACTUAL (FT) SECTION
BUSINESS 100 FT 58'-0" FIRST FLOOR 38.2.5.3.1 / 39.2.5.3.1
285'-4" BASEMENT (EXIST. NON-COMPLIANT)
EXIT ACCESS TRAVEL DISTANCE
OCCUPANCY ALLOWABLE (FT) ACTUAL(FT) SECTION
EXISTING BUSINESS 300 FT 271'-6" FT 38.2.6.3 / 39.2.6.3
CORRIDOR FIRE-RESISTANCE RATING
OCCUPANCY REQUIRED RESISTANCE RATING SECTION
BUSINESS NOT REQUIRED 38.3.6.1(3) / 39.3.6
MINIMUM CORRIDOR WIDTH
OCCUPANCY WIDTH (MINIMUM) ACTUAL SECTION
BUSINESS 44 INCHES 60 INCHES 38.2.3.2 / 39.2.3.2
DEAD ENDS
OCCUPANCY LENGTH (MAXIMUM) SECTION
BUSINESS 50 FT 38.2.5.2.1 / 39.2.5.2
PLUMBING SYSTEMS:
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
GROUP B OCCUPANCY REQUIRED PROVIDED TABLE
WATER CLOSETS MALE/FEMALE 7 MALE / 7 FEMALE 2902.1
1 PER 25 FOR THE 1 UNISEX
FIRST 50, THEN 1
PER 50
REQ'D: 6 MALE / 6 FEMALE
LAVATORIES MALE/FEMALE 7 MALE / 7 FEMALE 2902.1
1 PER 40 FOR THE 1 UNISEX
FIRST 80, THEN 1
PER 80
REQ'D: 5 MALE / 5 FEMALE
DRINKING FOUNTAINS 1 PER 100 4 DF PROVIDED 2902.1
REQ'D: 5 WATER AVAILABLE AT
STAFF LOUNGES
OTHER 1 SERVICE SINK 3 PROVIDED 2902.1
PROJECT INFORMATION:
REMODEL LOWER LEVEL AND FIRST FLOOR, AND CONSTRUCT 1-STORY ADDITION.
COLMERY-O'NEIL VA MEDICAL CENTER - BUILDING 2
TOPEKA, KANSAS
VA PROJECT NUMBER: 589-501
TYPE OF CONSTRUCTION (CONT):
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON NFPA 5000
FIRE SEPARATION DISTANCE TABLE 7.3.2.1
FIRE SEPARATION DISTANCE X (feet) BUSINESS OCCUPANCY
0 TO 5 1 HOUR
>5 TO ≤10 1 HOUR
>10 TO ≤ 30 0 HOUR
>30 0 HOUR
HATCH LEGEND
NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING
AREA NOT IN SCOPE
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans Health
Administration Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044
Phone: 785-842-6464 www.pec1.com
Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
ISSUED FOR BID
/2
/2
:5
:1
P
M A u to d e s k D o c s /1
.2
A tr ia x T o p e k a
V A
M e n ta l H e a lt h C lin ic
(M o d
.2
A
A tr ia x
T o p e k a V
A M e n ta l H e a lt h C lin ic
(M O
D
V
.r v t
G-002
CODE FLOOR PLAN - BASEMENT Outpatient Mental Health Clinic
Colmery-O'Neil VAMC Topeka, KS
589-501
03/29/24 FAB LD
0 10' 20'5'3/32" = 1'-0"A
BASEMENT CODE PLAN
N
SHEET TO BE PRINTED IN COLOR
S H
E E
T T
O B
E P
R
IN
T E
D I N
C O
L O
R
DN
DN
DN
DN
P. TLT.
A128
P. TLT.
A129 373 SF
SUD GROUP
THERAPY
C136
SUD OFFICE
C134
SUD OFFICE
C133
S. TLT.
C131
S. TLT.
C130
P. TLT.
C126
P. TLT.
C125
STOR.
C127
CAROTAS
C128
269 SF
STAFF LOUNGE
C129
MSA
A103
CHILDREN'S
WAITING
A104
P. TLT.
A105
ALCOVE
A106
VESTIBULE
A100
DRINKING
FOUNTAIN
A130
STOR.
C132
ELEC
C135
VESTIBULE
A102
HALL
A131
HOLD
D101
CONSULT
D102
BHIP OFFICE
D103
BHIP OFFICE
D104
BHIP OFFICE
D105
BHIP OFFICE
D106
IT
D107
CWT OFFICE
D108
VESTIBULE
D109
P. TLT.
D110
P. TLT.
D111
BHIP OFFICE
D112
STAFF WORK
D113
535 SF
CONF / CLASS
D114
BHIP OFFICE
D115
BHIP OFFICE
D116
BHIP OFFICE
D117
BHIP OFFICE
D118
BHIP OFFICE
D119
BHIP OFFICE
D120
BHIP OFFICE
D121
BHIP OFFICE
D122
BHIP OFFICE
D123
BHIP OFFICE
D124
BHIP OFFICE
D125
BHIP OFFICE
D126
BHIP OFFICE
D127
BHIP OFFICE
D128
BHIP OFFICE
D129
BHIP OFFICE
D130
646 SF
CONF
D131
BHIP OFFICE
D132
BHIP OFFICE
D133
BHIP OFFICE
D134
2089 SF
COURTYARD
D135
CORRIDOR
1CDR7
CORRIDOR
1CDR10
CORRIDOR
1CDR11
HALL
D136
ELEC
D137
ASSEMBLY OCCUPANT LOAD
(554 SF / 15 SF = 37 OCC.)
ASSEMBLY OCCUPANT LOAD
(373 SF / 15 SF = 25 OCC.)
COLLABORATION OCCUPANT LOAD
(269 SF / 30 SF = 9 OCC.)
ASSEMBLY OCCUPANT LOAD
(557 SF / 15 SF = 38 OCC.)
ASSEMBLY OCCUPANT LOAD
(686 SF / 15 SF = 46 OCC.)
ASSEMBLY OCCUPANT LOAD
(2095 SF / 15 SF = 140 OCC.)
LOBBY
A101
COMMON PATH OF EGRESS = 45'-6"
MAX = 100'-0"
EXIT ACCESS = 135'-0"
MAX = 300'-0"
EXIT ACCESS = 149'-11"
MAX = 300'-0"
EXIT ACCESS = 285'-4" (CONT. FROM BSMT.)
MAX = 300'-0"
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FARA
FAAP
FS
FS
FS
FS
FS FS
40" 0.2
68" 0.2
HSK
D138
60" 0.2
68" 0.2
S. TLT.
C130
STAFF PSYCH
A248
STAFF PSYCH OFFICE
A246
STAFF PSYCH OFFICE
A245
PSYCH NURSE
PRACTITIONER
A247
STAFF NURSE
A249
NURSE
PRACTITIONER
A250
STAFF SOCIAL
WORKER
A243
STAFF NURSE
A244
LOUNGE
A251
RR
A267
SOCIAL WORKER
A252
PSYCH NURSE
PRACT
A253
PSYCHIATRY RES.
A254
STAFF NURSE
A224
STAFF PSYCH
A237
STAFF NURSE
A238
SOCIAL WORKER
A239
CLINICAL PSYCH
A240
STAIR 2
A241
SUPPLY ROOM
A266
HOUSEKEEPING
A265
STAFF PSYCH
A236
STAFF NURSE
A235
SOCIAL WORKER
A234
STAFF NURSE
A233
MEN
A231
RR
A232
ELECTRICAL
A263
WOMEN
A230
ELECTRICAL
A264
WORK RM
A228
STAFF PSYCH
A256
NURSE
PRACTITIONER
A259
STAFF PSYCH
A257
NURSE
PRACTITIONER
A258
STAFF NURSE
A227
SOCIAL WORKER
A226
SOCIAL WORKER
A225
WAITING AREA
A255
RECEPTION
A268
EMS STORAGE (N.I.C.)
A279
CORRIDOR
A275
ELEVATOR #6
A276
LOADING DOCK
A294
ENGINEERING (N.I.C.)
A293
STAFF
PSYCHOLOGIST
A292
STAFF
PSYCHOLOGIST
A291
OFFICE
A290
STAFF RESTROOM
A295
MEDICAL MEDIA
A289
PHOTO STUDIO
A288
CCTV CONTROL
ROOM
A287
UNIVERSAL WASTE
A286
STAFF ONLY RR
A285 LOUNGE
A284
MEN
A283
OFFICE
A282
OFFICE
A281
PHARMACIST
A316
PHARMACIST
A315
BEHAVIORAL HEALTH
STAFF
A314
ELECTRICAL
A313
WOMEN
A312
SUPERVISOR
A317
ADDICTION
THERAPIST
A318
NURSE MANAGER
A319
SUICIDE PREVENTION
CASE MANAGER
A320
SUICIDE PREVENTION
COORDINATOR
A321
LOCAL RECOVERY
COORDINATOR
A322
CLINICAL PSYCH
A323
STAFF PSYCH
A324
HALL
A308
PSYCH SUPPLY
A310
HOUSEKEEPING
A311
WORK ROOM
A305
CLINICAL
OPERATIONS
SUPPORT
A304
MANAGEMENT
ANALYST
A303
ASSO. MANAGER
A302
BEHAVIORAL HEALTH
SERVICE
A301
NURSE MANAGER
A300
SERVICE LINE
MANAGER
A299
SECRETARY OFFICE
A297
MEN
A296
40" 0.2
40" 0.2
43 25
COMMON PATH OF EGRESS = 29'-1"
MAX = 100'-0"
.2 40"
.2
40"
CODE PLAN LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER RATING 2-A
FIRE DOOR ASSEMBLY RATINGFR
FACP
FS
FIRE ALARM STATION,
MANUAL PULL
FIRE ALARM CONTROL PANEL
FAAP FIRE ALARM ANNUNCIATOR PANEL
EXIT SIGN,
CEILING MOUNTED
WITH DIRECTIONAL ARROW
FEC
FIRE DEPARTMENT CONNECTION
TWO-WAY SIAMESE
2-HOUR FIRE BARRIER
COMMON PATH OF EGRESS TRAVEL
AND/OR EXIT ACCESS TRAVEL DISTANCE
Clear exit width provided Capacity factor per IBC Sect. 1005.3.2 Required exit capacity Occupant load at exit
REQUIRED EXIT WITH OCCUPANT LOADOccupant load served
EGRESS DOOR TAG
40" 0.2
HATCH LEGEND
NEW ADDITION/LOBBY IN CENTER PORTION OF EXISTING BUILDING
AREA NOT IN SCOPE
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans Health
Administration Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044
Phone: 785-842-6464 www.pec1.com
Atriax, pllc 703 Main Avenue SW, Hickory, NC 28602 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
ISSUED FOR BID
/2
/2
:5
:1
P
M A u to d e s k D o c s /1
.2
A tr ia x T o p e k a
V A
M e n ta l H e a lt h C lin ic
(M o d
.2
A
A tr ia x
T o p e k a V
A M e n ta l H e a lt h C lin ic
(M O
D
V
.r v t
G-003
CODE FLOOR PLAN - FIRST FLOOR Outpatient Mental Health Clinic
Colmery-O'Neil VAMC Topeka, KS
589-501
03/29/24 FAB LD
0 10' 20'5'3/32" = 1'-0"A
FIRST FLOOR CODE PLAN
N
SHEET TO BE PRINTED IN COLOR
S H
E E
T T
O B
E P
R
IN
T E
D I N
C O
L O
R
VENT GRATE
CP-106
947.77
CP 106
CP-108
INFORMATION
STOP
LP
942.49
LP
E
LP
940.90
LP
CROSS WALK
E
1" BUSH
(TYP. OF 3)
RI
VE
R
RO
CK
RI
VE
R
RO
CK
RI
VE
R
RO
CK
WV (TOP
NUT=940.78)
2" SAPLING
2" SAPLING
LP
943.50
LP
2" SAPLING
2" SAPLINGLP
942.33
LP
2" SAPLING
INFORMATION
PARKING
LP
941.36
LP
ELX
941.19
ELX
CROSS WALK
20" OAK
26" OAK
26" OAK
26" OAK
GRASS
GRASS
GRASS
GRASS
HORSESHOE PIN
HORSESHOE PIN
ELX
943.88
ELX
LP
CO
NC
RE
TE
CO
NC
RE
TE
CO
NC
RE
TE
LP
947.78
LP
HANDICAPPED
PARKING
HANDICAPPED
PARKING
HANDICAPPED
PARKING
MOTORCYCLE
PARKING ONLY
E
CO
CO
ASPHALT
ASPHALT
4" STEEL POST
946.58
4" STEEL POST
FFE=947.30
50" OPENING
FIRE
INDICATOR
VALVE
ELX
943.31
ELXWV (TOP NUT=940.58)
E
WV (TOP NUT=940.66)
PARKING
ASPHALT
ASPHALT
ASPHALT ASPHALT
DO NOT
ENTER
CROSS WALK
LP
946.66
LP
LP
946.39
LP
BBQ GRILL
BBQ GRILL
947.40
BBQ GRILL
BASKETBALL GOAL
VOLLEYBALL
NET POST
VOLLEYBALL
NET POST
BBA=937.44
BBA=937.48
SMALL AC
UNIT AT BBA
BWW=947.19
BBA=945.09
BWW=946.58
BBA=940.8
LP
948.71
LP
BOR P-1
946.68
BOR P-1BWW=943.21
BBA=940.74
BOR B-3
947.76
BOR B-3
BOR B-1
949.80
BOR B-1
BOR B-2
947.54
BOR B-2
BWW=947.05
BWW=944.42
BOR P-2
946.60
BOR P-2
BWW=944.03
BBA=940.28
BWW=946.22
FFE=950.51
66" OPENING
SPIGOT
18" MAPLE
LP
947.63
LP
31" SYCAMORE
40" OAK
SPIGOT
FFE=950.50
50" OPENING
CONCRETE
CONCRETE4"X4" STEEL PILLAR (TYP. OF 6)
RD
RD
ELR
(CAPPED)
FFE=948.02
50" OPENING
LP
944.30
LP
RI
VE
R
RO
CK 1" SAPLING
E
E
EMH
SIGNAL
20" OAK
20" OAK
30" OAK
FDC 2-B
SPIGOT
1" BUSH (TYP. OF 3)
RIVER ROCK
1" BUSH (TYP. OF 11)
32" OAK
32" OAK
CO
CO
1" BUSH (TYP. OF 4)
20" OAK
2" SAPLING
LP
944.90
LP
LP
945.97
LP
RI
VE
R
RO
CK
CROSS WALK
LP
947.38
LP
E
LP
948.21
LP
35" OAK
30" OAK
35" OAK
15" DECIDUOUS
18" PINE
1" BUSH (TYP. OF 15)
2" BUSH (TYP. OF 3)
CO
RD
RD
FFE=950.50
40" OPENING
SPIGOT
CO
LP
949.12
LP
LP
950.23
LP
1" BUSH
(TYP. OF 6)
STREET
RD A RD C LP
947.32
LP
LP
946.98
LP
ONE WAY
NO PARKING
HANDICAPPED
PARKING (TYP. OF 8)
LP
948.93
LP
LP
948.08
LP
LP
946.46
LP
NO
PARKING
LP
946.30
LP
LP
946.49
LP
FFE=950.47
45" OPENING
CO
1" BUSH (TYP. OF 16)
1" BUSH (TYP. OF 2)
2" BUSH
(TYP. OF 5)
SPIGOT
36" OAK DEDICATION
PLAQUE
DEDICATION
PLAQUE
SPIGOT
36" OAK
CO
1" BUSH (TYP. OF 5)
1" BUSH
RIVER ROCK
FDC
1" BUSH (TYP. OF 2)
CO
LP
946.38
LP
COCO
LP
946.71
LP
FFE=950.42
50" OPENING
FFE=950.42
66" OPENING
FFE=950.45
66" OPENING
FFE=950.46
50" OPENING
SPIGOT
SPIGOT
U E
U E U E U E U E
U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E
U E
U E U E U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E U E U E U E U E U E U E
U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E U E
U E U E U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT UT UT UT UT UT UT UT UT UT UT UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT UT UT UT UT UT UT UT UT UT UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
W W W W W W W W W W W W W W W W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W W W W
W
W W W W W W W
W
W
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E U E U E U E U E U E U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U
E U
E U
E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U
E U
E U
E
U E
U E
U E
U E
U E
U E U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E U E U E U E U E U E U E U E U E U E
U E
U E
U E
BWW=947.98
BWW=946.27
BWW=945.14
BBA=940.94
BWW=947.76
BWW=947.92
T
ST
AN
DA
RD
C &G
ST
AN
DA
RD
C &G
STANDARD C&G
STANDARD C&G
STANDARD C&G
ST
AN
DA
RD
C &G
ST
AN
DA
RD
C &G
ST
AN
DA
RD
C &G
ST
AN
DA
RD
C &G
STANDARD C&G
STANDARD C&G
ST
AN
DA
RD
C &G
ST
AN
DA
RD
C &G
STANDARD C&G
ST
AN
DA
RD
C &G
ST
AN
DA
RD
C &G
BUILDING 2
"C" ROAD (ASPHALT)
AS
PH
AL
T
"A " R
OA
D
(A
SP
HA
LT
"D" ROAD (ASPHALT)
CO
NC
RE
TE
CONCRETE
4' DUCT
4'
DU
CT
4' DUCT
ELECTRICAL
CONDUIT
4' DUCT
4' DUCT
4'
DU
CT
4' DUCT
4' DUCT
4'
DU
CT
4'
DU
CT
4'
DU
CT
ASPHALT
AS
PH
AL
T
CONCRETE
CONCRETE
CONCRETE
UNDERGROUND ELECTRICUNDERGROUND ELECTRIC
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CO
NC
RE
TECONCRETE
CONC
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
U E
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONC
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONC
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CO
NC
RE
TE
CONCRETE
CONCRETE
CONCRETE
CONC
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONC
CONCRETE
CONC
CONCRETE
CONCRETE (TYP. OF 2)
CONC
CONC
CONC
CONC
CONCRETE
CONC
CONC
CONCRETE
CONCRETE
CO
NC
RE
TE
CO
NC
RE
TE
CO
NC
CONCRETE
CONCRETE
CONC
CONCRETE
CO
NC
RE
TE
CONC
CONCRETE
CONC
SANDSAND
HORSESHOE STOP (TYP. OF 4) FENCE
UNKNOWN UTILITY
UNKNOWN UTILITY
RAM
P
VENT GRATEVENT GRATE
GRATE
VENT GRATE
GRATE
LIGHT POLE BASE
LIGHT
POLE
BASE
GRATE
GRATE
STONE TILE
HANDHOLE
J-BOX
GRATE
VE
NT
G
RA
TE
VENT GRATE
CANOPY
ELECTRIC BOX
PAVEMENT
MARKING
(TYP.)
PAVEMENT MARKING (TYP.)
PAVEMENT MARKING (TYP.)
PAVEMENT MARKING (TYP.)
PAVEMENT MARKING (TYP.)
VOLLEYBALL NET
GRATE
LIGHT
POLE
BASE
LIGHT
POLE
BASE
BR
OK
EN
C
UR
B
LIGHT
POLE
BASE
HANDHOLE
GRATE
VENT GRATE
STONE TILECOLUMN
COLUMN
COLUMN
COLUMN
CA
NO
PY
STONE TILE
STONE TILE
STONE TILE
FFE=950.51
STONE TILE
VE
NT
G
RA
TE
VENT GRATE
GRATE
GRATE
GRA
TE
VENT GRATE
GRATE
LA
ND
SC
AP
E E
DG
E
GRATE
BUILDING 1 SIGN
J-BOXBUILDING
2 SIGN
CONC
SIGN FOR LOT 6
TACTILE INSERT
RETAINING WALL
RE
TA
INI
NG
W
AL
L
RE
TA
INI
NG
W
AL
L
RETAINING WALL
BRICK SIDEWALK
CO
NC
RE
TE
S
ID
EW
AL
K
CONCRETE SIDEWALK
CO
NC
RE
TE
S
ID
EW
AL
K
CO
NC
RE
TE
S
ID
EW
AL
K
CO
NC
RE
TE
SI
DE
WAL
K
CO
NC
RE
TE
S
ID
EW
AL
K
CO
NC
RE
TE
S
ID
EW
AL
K
CO
NC
RE
TE
S
ID
EW
AL
K
" D
UC
TB
AN
K
" D
UC
TB
AN
K
" D
UC
TB
AN
K
" D
UC
TB
AN
K
" D
UC
TB
AN
K
" D
UC
TB
AN
K
36" DUCTBANK
36" DUCTBANK
36" DUCTBANK
36" DUCTBANK
36" DUCTBANK
36" DUCTBANK
7 94
U E
U E
U E
U E
U E
U E U E U E U E
J-BOX
HANDHOLE
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
"A " R
OA
D
(A
SP
HA
LT
U E
U E
U E
U EU E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
O E
X X
W
UT
G
UNDERGROUND ELECTRIC LINE
OVERHEAD ELECTRIC LINE
ROAD CENTERLINE
STORM SEWER PIPE
FENCE
WATER LINE
SANITARY SEWER PIPE
BUILDING LINE
UNDG. TELEPHONE LINE
UNDG. GAS LINE
LP
ELR
ELX
E
H
P
SD
GP
POST
Sign
FH
WV
CO
SS
T
BM387
IRP
CP389
SCR Section
SECTION CORNER
HORIZONTAL CONTROL POINT
PROPERTY IRON
BENCH MARK
TELEPHONE MANHOLE
SANITARY SEWER MANHOLE
CLEANOUT
WATER VALVE
FIRE HYDRANT
SIGN
GUARD POST
GATE POST
STORM DRAIN MANHOLE
ELECTRICAL TRANSFORMER
ELECTRICAL PULLBOX
ELECTRICAL HANDHOLE
ELECTRICAL MANHOLE
ELECTRICAL BOX
ELECTRICAL RISER
ELECTRICAL POWER/TRANSMISSION POLE
ELECTRICAL LIGHT POLE
LEGEND
REINFORCED CONCRETE PIPERCP
CORRUGATED METAL PIPECMP
POLYVINYL CHLORIDE PIPEPVC
STORM WATER AREA INLETSDA
STORM WATER CURB INLETSDC
CURB AND GUTTER C&G
FLOW LINE FL
FINISH FLOOR ELEVATIONFFE
OVERHEAD OH
SANITARY SEWER MANHOLESSM
MAJOR CONTOUR
MINOR CONTOUR ELEV
ELEV
LOT LINE
SETBACK LINE
EASEMENT LINE
RIGHT OF WAY LINE
DECIDUOUS TREE
CONIFEROUS TREE
POLYETHELENE PE
* ALL ITEMS IN SURVEY ARE DEPICTED IN THE
LEGEND, NOT ALL ITEMS IN THE LEGEND ARE
DEPICTED IN THE SURVEY.
BOR
SDC
SDA
NOT TO SCALE N.T.S.
STORM DRAIN AREA INLET
STORM DRAIN CURB INLET
BORING HOLE
HIGH-DENSITY POLYETHYLENE PIPEHDPE
CAST IRON PIPE CIP
DUCTILE IRON PIPE DIP
VITRIFIED CLAY PIPE VCP
RIGHT OF WAY R/W
BOOK BK
PAGE PG
CENTERLINE CL
RECORDINFORMATION SHOWN (LOCATION,
SIZE, MATERIAL, ETC.) IS FROM
RECORD DOCUMENTS. THIS
INFORMATION WAS NOT PHYSICALLY
MARKED OR LOCATED ON SITE
BOTTOM OF BUILDING ACCESSBBA
BOTTOM OF WINDOW WELLBWW
ROOF DRAIN RD
ELECTRIC MANHOLE EMH
FIRE DEPARTMENT CONNECTIONFDC
CONCRETE CONC
ELECTRICAL BOX ELX
ELECTRICAL JUNCTION BOXJ-BOX
HORIZONTAL DATUM/COORDINATE SYSTEM: NAD 83 (2011) KANSAS NORTH ZONE
PROJECT COORDINATE SYSTEM: (GRID) ON DESCRIBED COORDINATE SYSTEM
DISTANCE UNITS: US SURVEY FEET
HORIZONTAL CONTROL POINTS
CP-105
N: 259678.7431 E: 1959017.3445
1/2" REBAR IN THE SOUTHEAST QUADRANT OF ROAD "A" AND ROAD "O"
1. 2.5' S TO THE NORTHEAST CORNER OF THE SLAB FOUNDATION FOR A CAMPUS DIRECTIONS SIGN.
2. 3.0' N TO THE BACK OF CURB.
3. 36.0' WNW TO THE CENTER OF THE INTERSECTION OF ROAD "A" AND ROAD "O"
CP-106
N: 260152.9909 E: 1958991.8846
1/2" REBAR IN THE SOUTHEAST QUADRANT OF ROAD "A" AND ROAD "C".
1. 12.4' WNW TO THE SOUTHEAST CORNER FOR THE FOUNDATION FOR THE BUILDING 2 SIGN.
2. 28.4' N TO THE BACK OF CURB.
3. 19.9' S TO THE NORTHERN EDGE OF A SIDEWALK HEADED SOUTHEAST TO NORTHWEST.
CP-107
N: 260167.7537 E: 1959389.9762
1/2" REBAR SET IN AN ALLEY ON THE NORTHEAST SIDE OF BUILDING 2.
1. 2.2' W TO THE EAST EDGE OF A SIDEWALK.
2. 14.5' NE TO THE CORNER OF A STACKED STONE WALL.
3. 42.1' NW TO THE CENTERLINE OF ROAD "C" AT THE INTERSECTION OF PARKING DRIVE TO SOUTH.
CP-108
N: 259685.6147 E: 1959294.9882
1/2" REBAR SET ON THE SOUTH EDGE OF DRIVE TO LOT 8.
1. 2.5' W TO THE NORTHEAST CORNER OF THE FOUNDATION SLAB FOR THE SIGN FOR LOT 8.
2. 2.4' N TO THE BACK OF CURB.
3. 9.8' E TO THE WEST EDGE OF A SIDEWALK WITH STAIRS.
BENCH MARKS
BM-A
CHISELED SQUARE ON THE NORTH SIDE OF THE SECOND LIGHT POLE EAST FROM ROAD "A" ON THE SOUTH SIDE OF ROAD "O"
EL= 943.43
BM-B
CHISELED SQUARE ON THE NORTHWEST CORNER OF CONCRETE SLAB FOR UNDER GROUND UTILITIES ALONG THE NORTH SIDE OF ROAD "C"
EL= 946.36
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
Dwg. of o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .