Attachment 10 - Rooms Descoped From Project.docx

DOCX document 17 KB Posted

Attached to
Y1DA--EHRM Infrastructure Upgrade Construction - Mountain Home Federal contract opportunity
Solicitation number
36C77624B0024
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

Attachment 10 is a document detailing rooms descoped from a construction project at the James H. Quillen VA Medical Center for Project 621-22-700. The descoped areas span multiple buildings and floors, specifically Building 160's fourth floor, Building 200's first and second floors, and Building 204's second floor. While most trades are completely descoped from these areas, certain electrical, mechanical, and fiber backbone cabling work remains, including electrical circuits to telecommunication racks, grounding requirements, vertical rack PDUs, and UPS units. The document also requires bidders to submit unit pricing for additional Work Area Outlets, including labor and materials for Cat 6A cabling installation, terminations, and outlets, with the option to deduct outlets determined unnecessary.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--EHRM Infrastructure Upgrade Construction - Mountain Home, newest first.
File Type Posted
Redacted Bid Opening Abstract Statement - Mountain Home EHRM.pdf PDF
36C77624B0024 0011.docx DOCX document
Bid Opening Attendees List.docx DOCX document
36C77624B0024 0010.docx DOCX document
36C77624B0024 0009.docx DOCX document
Updated Technical Question Tracker - Mountain Home EHRM.xlsx XLSX spreadsheet
36C77624B0024 0008.docx DOCX document
Corrected Revised Specs - Mountain Home EHRM - Vol. 2.pdf PDF
Corrected Revised Specs - Mountain Home EHRM - Vol. 1.pdf PDF
Corrected Revised Drawings - Mountain Home EHRM - Vol. 2.pdf PDF
36C77624B0024 0007.docx DOCX document
Revised Drawings - Mountain Home EHRM - Vol. 1.pdf PDF
36C77624B0024 0006.docx DOCX document
Revised Specs - Mountain Home EHRM - Vol. 1.pdf PDF
Revised Specs - Mountain Home EHRM - Vol. 2.pdf PDF
Revised Drawings - Mountain Home EHRM - Vol. 2.pdf PDF
Attachment 12 - RFI 39 - WAO Pricing.docx DOCX document
Technical Question Tracker - Mountain Home EHRM.xlsx XLSX spreadsheet
Revised Attachment 10 - Rooms Descoped From Project.docx DOCX document
36C77624B0024 0005.docx DOCX document
36C77624B0024 0004.docx DOCX document
36C77624B0024 0003.docx DOCX document
Attachment 12 - Redacted Brand Name Justification.pdf PDF
Attachment 8 - Wage Determination - Washington County TN - 6-6-2025.pdf PDF
36C77624B0024 0002.docx DOCX document
S06 - 36C77624B0024 0001.docx DOCX document
S06 - Site Visit Sign In Sheet.pdf PDF
36C77624B0024.docx DOCX document
Attachment 2 - EHRM_IFB_Spec_Vol2_05222025 1.pdf PDF
Attachment 4b - EHRM_Moutain Home_EHRM_IFB_Dwgs VOL 2b.pdf PDF
Attachment 7 - Asbestos Survey Report 2.pdf PDF
Attachment 1 - EHRM_IFB_Spec_Vol1_05222025 1.pdf PDF
Attachment 4a - EHRM_Moutain Home_EHRM_IFB_Dwgs VOL 2a.pdf PDF
Attachment 11 - Site Visit Instructions.docx DOCX document
Attachment 8 - Construction Wage Rates - Washington County TN - 5-2-25.pdf PDF
Attachment 9 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 3a - EHRM_Moutain Home_EHRM_IFB_Dwgs VOL 1a.pdf PDF
Attachment 3b - EHRM_Moutain Home_EHRM_IFB_Dwgs VOL 1b.pdf PDF
Attachment 5 - List of TRs and TEs 5.20.2025.pdf PDF
Attachment 6 - Mtn Home Port List Report.xlsx XLSX spreadsheet
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

James H. Quillen VA Medical Center Project 621-22-700

These items in construction documents are descoped from the project.

Bldg. 160 Fourth Floor All trades descoped with the following exceptions.

· Electrical, and A/B path fiber backbone cabling indicated for TRN4616 shall be applied to existing IT Room N4537.

· Electrical, mechanical and A/B path fiber backbone cabling for TR P4128

Note: Electrical includes normal and emergency circuits to telecommunication racks, grounding requirements, vertical rack PDUs, zonit PDUs, and UPS units as shown for the original locations.

Bldg. 200 First Floor All trades in Rooms D102B, D102A, D102, D101, D102, D103, D104, D105, D106, D107, D108, D109, D110, D111, D112, D113, D114, D115, D117, D116, D118, D120, D122, D159, D151, D156, D119, D127, D158, D121, D160, D162, D121, D128, D164, D128, D125 and D166.

Bldg. 200 Second Floor All trades in Rooms D202, D201, D203, D204, D205, D206, D207, D208, D209, D210, D211, D212, D213, D214, D215, D216, D217, D218, D219, D220, D221, D222, D223, D225, D226, D249, D251, D253, D256, D258, D260 and D262.

Bldg. 200 Second Floor All trades in Rooms E203, E204, E205, E206, E207, E208, E209, E210, E211, E212, E213, E214, E216, E218, E220, E222, E243, E245, D244, D426, D248, D250, D252 and D232.

Bldg. 204 Second Floor All trades in Rooms L201, L202, L203, L204, Holter 210-L205, Interp. Rm. 210-L206, Echo 210-L207, L210, L206, L206A, , L208, L209, L209A, L210, Lockers/Breakroom 210-L215A, L211, L212, L212A, L213, L213A, Fellow Doctors 210-L214, Storage 210-L215, L217, L240, L241, L242, L243, L244, L245, L233, L252, L264, L270, L271, L273, L274, L275, L276, L277, L226, L227, L230, L234, L235, L236, L237, L238, L239, L240, L241, L242, L243, L244, L245, L248, L248A, L248B, L249, L249, L249B and L250.

Bidder shall submit unit price for additional Work Area Outlets to include labor and materials to install Cat 6A cabling (80m x 3), terminations and outlet.

Bidder shall submit unit price to deduct Work Area Outlets determined to not be needed.

File details come from the government source that posted it. Updated .