S06 Response to Vendor Questions 36C26326Q0870 0002.docx

DOCX document 156 KB Posted

Attached to
Central Iowa VHA Health Care System Surgical Instrument Maintenance and Repair Solicitation
Solicitation number
36C26326Q0870
Issued by

About this file

This is a Response to Vendor Questions document (Amendment 0002) for a surgical instrument maintenance and repair solicitation issued by the Department of Veterans Affairs Veterans Health Administration (VA-VHA) through the Network Contracting Office 23 in Saint Paul, Minnesota. The amendment addresses 28 vendor questions and clarifies the Statement of Work (SOW) requirements for the Central Iowa Veterans Health Care System (CIHCS).

The contract requires comprehensive maintenance and repair services for approximately 950 surgical instrument sets/trays at the Central Iowa VAMC in Des Moines, Iowa. Services must include biweekly onsite repairs via a mobile repair lab, preventative maintenance, and emergency repair capabilities. Critical instrument sets must be completed within one week; routine sets within two weeks. The VA clarified that specialty devices (power equipment, video systems, cameras, scopes, dental handpieces, laser equipment) have been removed from the inventory and will not be covered. Contractors may perform repairs at approved off-site facilities with SPS Chief approval, though some instruments require digital QR code tracking upon return. The contractor must provide a 24/7 accessible online digital inventory dashboard, staff training documentation, security badge compliance, and monthly service reports. All repairs must conform to original manufacturer specifications and meet CDC, HSPA, AORN, APIC, ANSI, and AAMI standards. Pricing should be based on the provided schedule using unit pricing for critical and routine instrument set maintenance and repair. The question deadline was 07/03/2026, and the offer deadline is 07/24/2026, both at 17:00 Central Time.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer)

07-15-2026

36C263

DEPARTMENT OF VETERANS AFFAIRS

NETWORK CONTRACTING OFFICE 23

316 ROBERT STREET N, SUITE 506

SAINT PAUL MN 55101

DEPARTMENT OF VETERANS AFFAIRS

NETWORK CONTRACTING OFFICE 23

316 ROBERT STREET N, SUITE 506

SAINT PAUL MN 55101

To all Offerors/Bidders

36C26326Q0870 06-25-2026

X

See following pages.

Jeffrey Brown Contracting Officer

VA-VHA-RPOC-2024-0033

The purpose of this amendment is to:

1. Respond to vendor questions.

2. Edit the Statement of Work. Changes highlighted.

See attached document: Instrument Trays Utilization 7.13.26.

Vendor questions in bold, VA responses in red.

1. The SOW states that "the repairer must be able to provide onsite, twice-weekly repairs for (i) unscheduled repair needs and (ii) same-day PM services for critical sets."

Has been updated to biweekly repairs. See SOW.

2. Can the VA clarify whether alternative service methods, including expedited pickup, repair at a qualified repair facility, and return of equipment, would satisfy this requirement when such an approach achieves equivalent or improved turnaround times and minimizes equipment downtime?

The following language has been added to the SOW:

“The CIHCS, at its own discretion and cost, may ship instruments the Contractor to expedite repair times, however, the Contractor shall be responsible for the cost of return shipping the instruments to the CIHCS.”

3. Can the VA define the acceptable turnaround time expectations for repairs that cannot reasonably be completed during an on-site visit?

Acceptable turn around for critical items is one week, longer times must be approved by the CIHCS. Two weeks is acceptable for noncritical items, longer times approved by CIHCS. The SOW has been updated to reflect these changes.

4. For repairs requiring specialized processes, such as bipolar instrument repairs involving coating, potting, environmental controls, or manufacturer-specific procedures, may those services be performed at an approved repair facility rather than on-site? If not, please identify any repair categories that must be performed on-site.

Yes, specialized repairs may be performed at an approved repair facility but must be approved by the SPS Chief or designee prior to sending out.

SOW has been updated to reflect this.

5. The inventory provided appears to include assets beyond traditional surgical instrument repair services, including power equipment, video systems, cameras, positioning devices, and other surgical equipment.

Power equipment, video systems, cameras and other specialty instruments have been removed from the inventory list.

6. Can the VA clarify which equipment categories are intended to be included within the scope of this contract?

The instrument categories/classes covered by this solicitation can be found in section 14 of the SOW “Covered Instrument Classes” and the attachment “Instrument Classes and Repairs” which lists additional covered instrument classes.

7. Are all listed assets intended to be covered under the contract value, or are certain equipment categories expected to be excluded and supported through separate service programs?

All listed instrument classes shall be covered under this contract and those that are not listed are not shall not be covered under this contract.

8. If these assets are included, can the VA provide a complete inventory by asset type and quantity to support accurate pricing and service planning?

The most accurate and current inventory that the CIHCS can provide is Appendix A and Appendix B set lists.

9. The solicitation references approximately 950 trays/sets, tray-based pricing, and an overall contract ceiling amount. Can the VA confirm that the stated contract ceiling value is accurate?

The Contract ceiling is based off of Government estimates but vendors are free to submit quotes that go above the contract ceiling.

10. Can the VA provide the historical repair volume, tray utilization data, or workload assumptions used to establish both the contract value and anticipated service requirements?

The best we can provide is the attached “Instrument Trays Utilization 7.13.26” showing annual usage of trays. The accuracy of the spreadsheet is not guaranteed.

11. Should offerors develop pricing based on total inventory quantity, actual utilization, trays serviced, historical repair volume, or another methodology preferred by the VA?

Vendors should be basing their pricing based on the schedule, Statement of Work and other terms and conditions of the solicitation and its attachments.

12. Does the listed inventory represent assets that may require service during the contract term, or assets expected to receive recurring service regardless of utilization?

All instrument sets will require at least once a year preventative maintenance and repair.

13. Certain repairs may require specialized capabilities that are not available during on-site service. Can individual instruments requiring specialized repair be removed from a tray/set and processed separately through an approved repair facility?

Yes, this shall be approved by the SPS Chief or designee and shall be tracked by the instrument and tray.

14. When operationally feasible, would the VA permit the remaining functional tray/set to be returned to service while the individual instrument undergoes repair?

Yes.

15. Does the VA prefer service approaches that prioritize returning functional trays and sets to service as quickly as possible while individual components receive specialized repair?

Yes, however the CIHCS must be notified when a tray is missing an instrument.

16. The solicitation appears to contemplate pricing based on tray/set quantities. Given that individual instruments may be repaired independently of a tray assembly, instruments may be added or removed from sets over time, and repair requirements can vary significantly across assets, would the VA consider a Comprehensive Firm-Fixed-Price (FFP) Service Program utilizing a single contract line item (CLIN) or other consolidated pricing structure to cover all services required under the SOW?

No.

17. If a Comprehensive Firm-Fixed-Price approach is acceptable, would the VA consider revising the pricing schedule to reflect a consolidated contract value rather than unit-based tray/set pricing?

See above.

18. Can the VA confirm that detailed repair documentation, service reports, asset tracking records, and repair history can be provided independently of the invoicing methodology to ensure full contract oversight and transparency?

Yes, the information listed in the question above should be accessible via the digital inventory system, as covered under section 10 of the Statement of Work, and may be described in a manner differing from that of the schedule. However, invoicing must still be performed in accordance with the schedule.

19. The Statement of Work and supplemental repair documentation appear to include repair services for equipment beyond standard stainless-steel surgical instrumentation.

a. Please confirm whether the scope includes specialty devices such as:

• Rigid and flexible scopes – No.

• Camera systems - No.

• Power equipment and handpieces – No.

• Phaco handpieces – No.

• Dental handpieces – No.

• Laser handpieces, fibers, and accessories - No.

• Specialty cables and related surgical accessories – No.

20. For any specialty devices included in the scope, can the Government provide an inventory list identifying the manufacturer, model number, and quantity?

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

21. What is the estimated number of Critical Instrument Sets/Trays expected to require maintenance and repair per month?

We cannot provide usage data for month to month, the estimated repair/preventative maintenance quantities in the schedule for critical and routine sets is based on the assumption of at least one instance of repair and/or preventative maintenance occurring every year with additional quantities added on for buffer. If we divide these estimated quantities by twelve months, we arrive at approximately 18 critical sets and 62 routine sets requiring repair/preventative maintenance per month.

21. What is the estimated number of Routine Instrument Sets/Trays expected to require maintenance and repair per month?

22. For specialty equipment such as dental handpieces, laser systems, scopes, cameras, power equipment, and other non-standard surgical devices: Can the Government provide historical repair volume and usage data, if available?

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

23. Are contractors expected to perform repairs directly, or are OEM-authorized repair services acceptable when required by the manufacturer?

Contractor or subcontractor maintenance and/or repair of instruments is acceptable as long as compliance with the terms and conditions of the contract is maintained.

24. The pricing schedule requires offerors to provide unit pricing for Critical Instrument Set Maintenance and Repair and Routine Instrument Set Maintenance and Repair. Traditionally, per-set pricing is based upon the repair and maintenance of surgical instrument trays and the instrumentation contained within those sets. However, the Statement of Work and supplemental repair requirements appear to include laparoscopic instruments, specialty devices such as dental handpieces, scopes, power equipment, cameras, phaco handpieces, laser equipment, fibers, and related accessories.

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

25. Confirm whether offerors are expected to include the repair costs associated with specialty devices within the unit pricing for Critical and Routine Instrument Sets.

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

26. If specialty device repairs are to be included within the tray-based CLIN pricing, please provide the equipment inventory and any available historical repair volume data so offerors may develop realistic and consistent pricing assumptions.

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

27. Given the significant variability and potentially high costs associated with repairs to scopes, dental handpieces, cameras, power equipment, laser systems, fibers, OEM components, and other specialty devices, will the Government consider establishing separate CLINs for these items rather than requiring such costs to be incorporated into per-tray pricing?

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

28. If separate CLINs will not be established, how does the Government intend for offerors to account for the cost of specialty device repairs under the current pricing structure?

No specialty devices/instruments are or will be included in the contract inventory. Any previously listed in the inventory have been removed.

B.4 Statement of Work Central Iowa Veterans Health Administration Health Care System Surgical Instrument Maintenance and Repair

The Central Iowa Administration Health Care System (CIHCS) requires surgical instrument Preventative Maintenance (PM) and repair services for their Surgical Processing Suite (SPS). The Contractor shall provide an online digital inventory system, or digital tracker, to track instrument repair status and requests that is accessible by the CIHCS.

1. Preventative Maintenance and Repair

a. “Instrument(s)” for this requirement mean: individual general surgical instrument identified during assembly inspection or front line use as not functional and requires evaluation and repair.

b. “Instrument Set(s)/Trays” for this requirement mean: a uniquely named instrument set/tray used to contain a series of instruments defined by an instrument count sheet. Sets may be between 1 and up to 612 individual instruments used during invasive procedures.

i. The instrument set is assembled and held inside of a container system where most instruments will stay inside the set over repeated use.

ii. An instrument set may include multiple levels of instruments inside one instrument set.

iii. All instruments sent out within the instrument set must return with the instrument set.

c. “Critical Instrument set”: Instrument sets listed below in Appendix A. Critical sets cannot be removed from circulation for more than two to three days at a time without approval of the SPS Chief or designee.

d. “Routine Instrument Set”: All non-critical instruments sets, identified in Appendix B.

e. Preventative maintenance of surgical instruments shall be done by the inspection of entire trays.

f. Repairs and preventative maintenance shall align with the original manufacturer’s design and product specifications.

g. Instruments subject to repairs and preventative maintenance shall be returned to a state near or at its original OEM specifications in terms of functionality and appearance.

h. Any modification or repair performed during repair that deviates from the OEM functional or physical specifications for the instrument will render the instrument “damaged beyond repair” and will need to be replaced at the expense of the repairer per FAR 52.212-4(b).

i. The Contractor shall ensure repairs and service functions are performed in conformance, the Center for Disease Control (CDC) regulations, Healthcare Sterile Processing Association (HSPA), Association of Peri-Operative Registered Nurses (AORN) Standards, Associate for Professionals in Infection Control and Epidemiology (APIC), the American National Standards Institute (ANSI) and Association for the Advancement of Medical Instrumentation (AAMI).

j. The following instruments general repairs and preventative maintenance shall be provided as appropriate:

i. sharpened,

ii. adjusted,

iii. aligned,

iv. straightened,

v. calibrated,

vi. cleared of rust or debris,

vii. oiled

viii. removal of stains, sharp edges and/or scratches

ix. cannulated/lumened items shall have interior lumen flushed and visually inspected.

x. all instruments able to be disassembled, shall be disassembled and undergo a detailed inspection.

k. The above list of instrument general repairs and preventative maintenance under j. and section 14 “Covered Instrument Classes” are supplemented by the attached “Instrument Classes and Repairs” that outlines all the potential classes of instruments that may require repair under this contract and all the potential repairs necessary for those instruments. The instrument and repair list in the attachment is not representative of the current instrument inventory at the CIHCS, it is to be used to establish all possible instruments and repairs/preventative maintenance that are covered under this contract under the circumstances those instruments were added into or already exist in the CIHCS inventory.

l. Returned Instruments shall have legible QR Code, manufacturer name, and instrument catalog number.

m. The Contractor shall provide maintenance and repair for rigid instrument containers to ensure that all lid gasket vent devices are fully functional, in accordance with manufacturer specifications.

n. Items deemed unrepairable need to be returned to facility with clear identification as such.

o. Any non-OEM parts used to repair an instrument must have product part numbers provided and must have a Food and Drug Administration (FDA) approved Instructions for Use (IFU) that outlines all steps for reprocessing.

p. The repairer must be able to provide onsite biweekly repairs for:

i. Unscheduled repair and PM needs

q. Site visits shall follow a set schedule and be arranged so there is a minimum of 2 weeks between service site visits.

r. During repair and PM, all instruments are to be evaluated for a 2D QR scan code. When a device does not have a 2D laser code, the repairer will place a laser marked QR code on the instrument, as part of the PM service contract or will flag the instrument.

i. Devices with new QR codes shall be returned as part of the set it arrived in.

ii. Notification of code placement needs to be communicated to facility via the digital tracker for entry into Censitrac, information to be documented on the digital tracker are:

1. Device product number,

2. Device description

3. Device serial number (if applicable)

4. QR code numeric assignment.

iii. The Contractor shall place a QR code on the instrument using a laser etching system if no etch is present.

s. Delicate sharp, pointed instruments delivered in puncture proof containers shall returned be returned in puncture proof containers.

t. Routine individual instruments that need to have part replacements or more complex repairs, can be relocated to facility repair shop with updates of location change provided via the digital tracker.

u. Any instruments that fail the quality check upon return to CIHCS shall be resubmitted to the Contractor for repair at the Contractor’s expense per Federal Acquisition Regulations (FAR) 52.212-4(a).

v. All single instruments and surgical trays picked up and delivered back to the hospital shall be updated by the Contractor on the digital tracker and following information shall be included for each:

i. Instrument

1. Name of instrument,

2. Manufacture catalog number,

3. Serial number (when applicable),

4. Quantity of items for accountability,

5. QR code number assigned to the item.

ii. Instrument set:

1. Instrument set name,

2. Tray actual number,

3. # of instruments included.

2. Prohibited Repairs

a. Any instrument found having an unreadable or non-existent Manufacturer’s name AND product number visible on the instrument are NOT considered valid reusable instruments.

i. These instruments shall be marked as “damaged beyond repair” and returned to SPS.

ii. Any repairs performed on these instruments will not result in compensation.

b. The Repairer is prohibited from knowingly altering or modifying an original instrument in ANY WAY from the original manufacturers intended design.

c. Any instrument rendered damaged beyond repair due to performance of the repair or preventative maintenance will be replaced at the Contractor’s expense. This can include but not limited to:

i. Sandblasting shiny instruments to make them dull.

ii. Removing the manufacturer’s name or product number found on the instrument.

iii. Altering the product dimensions, angles, length, or adding/removing materials.

iv. Creating a “custom” instrument.

3. Refusal to Repair

a. The contractor shall not classify any instrument(s) as irreparable without providing, concurrently with the return of the instrument(s) to CIHCS:

i. Written justification citing the specific conditions preventing repair.

ii. Photographic documentation.

iii. Evidence of repair attempt.

iv. Approval of the instrument(s) by a CIHCS representative.

b.

4. Repairer Response window:

a. Urgent instrument repair service: Unscheduled repair of critical individual instrument or instrument set which the following applies:

i. The damage is identified on a day where no onsite visit is anticipated.

ii. The damaged item is a critical instrument for the instrument set.

iii. No alternative substitution available in house to meet the need while waiting for repair.

iv. Patient care delays or cancellations.

b. The Contractor has a week to complete urgent instrument repairs. The week starts at the time of notification by CIHCS to the Contractor.

c. Instruments or sets necessitating emergency repairs may be shipped to Contractor facilities if necessary. The CIHCS, at its own discretion and cost, may ship instruments the Contractor to expedite repair times, however, the Contractor shall be responsible for the cost of return shipping the instruments to the CIHCS.

5. Place of Performance

a. The mobile repair lab will provide onsite repairs at the VA Central Iowa Health Care System, 3600 30th Street, Des Moines, Iowa 50310.

b. Instruments are to be picked up from the SPS Preparation Area and OR.

c. Instruments are to be returned to the SPS Decontamination Area.

d. Off-site repairs: For Contractor's designated facility the address and certification (ISO 13485:2016 certification or VA determined equivalent) provided to COR prior to performance and upon any change.

e. Off-site repairs are allowable after receipt of permission from the CIHCS.

6. Scheduled PM for Critical Instrument Sets:

a. See Appendix A for the list of critical instruments.

b. Preventative maintenance of critical instrument sets shall be scheduled, and work completed within a week. Any exception to the week turnaround time is permissible from the COR or another CIHCS representative.

c. In the event this is not attainable this is to be communicated directly and immediately with SPS Designee to include what complications are creating a barrier and an ETA of expected downtime.

d. Off-site repair is allowable for critical instrument sets assuming the repairs are completed within the required timelines for critical instrument sets.

7. Scheduled PM for Routine Instruments Sets:

a. See Appendix B for the list of routine instrument sets.

b. The Contractor shall have 2 weeks, or longer at CIHCS discretion, to complete routine preventative maintenance on surgical instrument trays with day of pick up considered as day one (1).

c. If a set will be removed from circulation for longer than two weeks, this needs to be directly communicated with the SPS designee and an explanation as to why.

d. Off-site repair is allowable for routine instrument sets.

8. Mobile Repair Lab Requirements

a. Instrument repairs completed onsite at the Central Iowa Veterans Administration Medical Center (VAMC) shall occur in a mobile repair lab/vehicle in a designated space. CIHCS is not responsible for the supply of any items or utility services of any kind needed for the sustainable functioning of the mobile unit.

b. Safety cones shall be utilized around the perimeter of the mobile repair vehicle to ensure the safety of hospital and Contractor staff.

c. Any equipment requiring set up at the mobile repair lab at the hospital shall be done at the expense of the Contractor.

d. Mobile Repair Unit shall properly display the Contractor’s name and permit numbers.

e. The contractor shall provide access to repair facilities (mobile or otherwise) upon request by the VA to ensure compliance with the contract and applicable regulatory standards.

f. Contractor mobile unit(s) shall be registered with the CIHCS Police Department.

9. Contractor documentation and tracking requirements

a. Accessible online service dashboard that displays and tracks all repair and maintenance activities.

b. Contractor uses an online dashboard that displays and tracks all repair and maintenance activities.

c. The dashboard must be online and must be accessible to SPS designees 24 hours a day, 365 days a year except for maintenance related down times.

d. The following dashboard functions must be included:

i. Repair request function,

ii. Scheduled maintenance request function,

iii. Critical repair request function,

iv. Display request is received with date of anticipated repair,

v. Status updates while active repair is being performed,

vi. Closed “completed” repairs with all associated documentation attached,

vii. Visible annual calendar that establishes an annual PM schedule for sets attached in the appendixes,

viii. The dashboard shall allow for all repairer documentation to be attached directly to the repair request

ix. This shall include a preventative maintenance checklist with at least:

1. Repair performed,

2. What parts were ordered,

3. Invoices,

4. Any other related documentation,

e. Repair services that Interface with current equipment and Censitrac program are preferred.

10. Contract Monitoring:

a. The CIHCS SPS shall designate a representative to monitor Contractor employee work services through one or a combination of the following mechanisms:

i. The SPS representative, SPS Chief, Reusable Medical Equipment (RME) Coordinator and/or Contracting Officer Representative (COR) shall monitor Contractor instrument pick-up and drop-off through the inhouse Censitrac system to ensure that services called for in the contract have been received by the CIHCS.

ii. SPS shall utilize Contractor’s digital dashboard to request services from Contractor. Daily monitoring of digital dashboard and repair status to ensure all requests are being handled appropriately.

iii. Documentation of services performed shall be reviewed by the Contracting Officer Representative prior to certifying payment.

iv. The SPS representative will conduct periodic customer service interviews with end users to confirm quality repair services are being performed to their standards.

v. Contract monitoring and recordkeeping procedures shall be sufficient to ensure proper payment and confirmation that services were provided.

vi. Monthly invoices shall be submitted to the SPS Representative and COR at the beginning of the contract, until it is determined that billing documentation meets requirements. Once billing practices have been found to be acceptable then invoices may be directly submitted to Tungsten. The COR shall verify that services were performed against Contractor’s certified delivery repairs document. Only after verification are invoices certified for payment. Billing disagreements that cannot be resolved by the COR shall be forwarded to the Contracting Officer for review and resolution.

vii. The CIHCS SPS representatives retain the option to perform site visits of Contractor repair facilities to confirm that repairs are being performed in accordance with the requirements listed above.

viii. The Contractor shall provide monthly reports as requested, detailing the work performed that month.

11. Contractor Requirement

a. Contractor shall have a training program or third-party training program for their staff who will be providing services on this contract. Any Contractor staff performing services on this contract shall have completed the aforementioned training.

b. The Contractor shall provide documentation of staff training, competencies, and any pertinent certifications in relation to the repairs they shall be conducting upon CIHCS request.

c. The contractor shall provide CIHCS SPS staff with in-service training on as needed basis, at the request of the facility. Up to a total of six (6) hours, two (2) per shift, CEU eligible in-services, on instrumentation, per year.

12. Security Clearance

a. The following security language is applicable to Contractor staff who will regularly enter CIHCS facilities.

b. Contractor staff will utilize a temporary Contractor’s security badge until a permanent security PIV badge can be issued. Temporary badge use will not exceed 30 calendar days.

c. The Contractor shall comply with Central Iowa VAMC security, access, and badging requirements. Employees must provide fingerprints and be able to pass a background check so they can obtain a security access badge.

d. All Contractor staff will need a valid individual personal or professional email account that can be easily checked. Notifications regarding fingerprint scheduling/appointments, background investigation tasks, and Training Management System (TMS) required classes will be sent to their email address throughout the badging process.

e. The Contractor will submit all required security badging documents for each employee within fifteen (15) business days from the award date of contract to the COR. All documents must be legible. The following documents will be sent to the Contractor via email after contract is awarded.

i. OF 306 – Must be Typed. Submission of handwritten forms will not be acceptable.

ii. Self-Certification

iii. VA 10-2417

iv. Employee Fingerprint Resource Form

f. Appropriate Contractor staff (as determined by the VA) performing the duties of the Statement of Work shall complete the computer-based training course “TMS 10176 Infosec/Rules of Behavior”.

g. Contractor staff shall be escorted while in CIHCS sensitive locations or without a security badge or PIV badge.

13. Additional Information

a. National Holidays. There are eleven (11) holidays observed by the Government as follows: New Year’s Day, Martin Luther King Day, Presidents Day, Memorial Day, Juneteenth Independence Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas Day. SPS is a 24/7 operation and continues sterilization operations on these holidays.

b. Repairs must be performed in a clean and orderly environment.

14. Covered Instrument Classes (Including but not limited to):

General Scissors:
Metz Scissors, Mayo Scissors, Cast/Bandage Scissors, Iris Scissors, Suture Scissors, Serrated Scissors, Delicate Scissors
Osteotomes:
Total Joint Osteotomes, Podiatry Osteotomes and ENT Osteotomes
Curettes:
Total Joint, Curettes, D & C Curettes, Adenoid Curettes
Elevators:
Periosteal Elevators, Cobb Elevators, Key Elevators, Freer Elevators, DIE Elevators
Gouges:
Total Hip Gouges
Small Knives:
Amputation Knives, Cartilage Knives, Meniscus Knives, Knife Handles
Rongeurs:
AB Rongeurs, Pituitary Rongeurs, Kerrison Rongeurs, Kerrison Punches, Dermal Punches
Cutters:
Bone Cutters, Wire Cutters, Pin Cutters, Rib Cutting Forceps
Forceps/Clamps:
Artery Forceps, Sponge Forceps, Kelly Forceps, Adson Forceps, Allis Forceps Tissue Forceps, Mosquito Forceps, Biopsy Forceps, Hemostats, Clip Appliers, Kocher Clamps, Towel Clips/Clamps, Bone Clamps
Miscellaneous Instruments:
Reamers, Total Hip Cup Graters, Cranial Burrs, Enlarging Burr, Retractors, Balfour Retractor, Hand Retractors, Perforating Twist/Spinal Drills, Chisels, Tonsillectomies, Adenotomes, Trocars, Skin Hooks, Skin Rakes, Suction Tips/Tubes, Dissectors, Rasps, Mouth Gags, Saw Blades, Speculums, Dilators, Dental Instruments, all needle holders, Acetabular Cutters
Ophthalmic Instruments:
Speculums, Retractors, Knives (not diamond), Spoons, Punches, Spatulas, Manipulators, Loops, Hooks, Markers, Calipers, Scissors, Forceps
Arthroscopic Instruments:
Punches, Shavers, Scissors, Intra-Articular Hooks, Intra-Articular Knives, Intra-Articular Graspers, Forceps
Align/Sharpen Laparoscopic Instruments:
Laparoscopic Punches, Laparoscopic Shavers, Laparoscopic Scissors, Laparoscopic Hooks, Laparoscopic Knives, Laparoscopic Graspers, Laparoscopic Forceps
Micro Instruments:
Verres Needles, Biopsy Needles, Corneal Scissors, Urethra tomes, Micro Rongeurs, Micro Forceps Micro Scissors
Bi-Polar Repairs:
Standard Bipolar, Irrigating Bipolar, Standard Bipolar, Irrigating Bipolar
Sterilization Container Repair:
Aesculap, Katena, Case Medical
Endoscopic and Laparoscopic Instruments (modular and non-modular):
Graspers, dissectors, scissors, clamps, biopsy instruments and forceps (to include with or without ratchets).
Light Cables and adaptors to fit all manufacturers:
Light Cable 3mm x 6 ft w/2 adaptors, Light Cable 3mm x 8 ft w/2 adaptors, Light Cable 4mm x 6 ft w/2 adaptors, Light Cable 5mm x 6 ft w/2 adaptors, Light Cable 5mm x 8 ft w/2 adaptors

The lists provided below are not all inclusive of the instruments that will be on the contract over its lifetime and may be subject to change over time.

APPENDIX A:

· Critical sets: Appendix A- high risk.

Service
Container Name
Number of Sets
Instrument
Clinic
Minor Clinic
2
19
Dental
Straumann Implant Kit with AS
5
16
Dental
Standard Oral Surgery
6
25
OR - Basic
Basic Set
4
44
OR - Delicate
Duet Forcep
2
3
OR - Eye
Cataract Trays
10
35
OR - Eye
Toric Instrument Set
4
4
OR - Eye
Lacrimal Duct Probes
1
4
OR - Eye
Pterygium (Plastics Eye Tray)
2
26
OR - Eye
Katena Cataract Extras
4
4
OR - General
Lap Chole Set New 2018
4
22
OR - General
Rectal Set
3
26
OR - General
Needle Holder & Knot Pusher 2018
2
5
OR - General
Closure Tray
2
19
OR - General
Bookwalter Bars
1
8
OR - General
Bookwalter Blades
2
21
OR - General
Bookwalter Bar #2
1
9
OR - General
Lap Chole Extras 2018
2
12
OR - General
Adjustable Bookwalter Ring/Bar (Codman)
1
12
OR - General
Bookwalter Blades Extras
1
10
OR - Laparoscopic
Karl Storz Scope Holder
2
6
OR - Laparoscopic
Princeton Long Laparoscopic Set
2
43
OR - Lesion
Lesion Set
6
28
OR - Ortho
Ortho Basic
4
44
OR - Ortho
Ankle Distractor
1
3
OR - Retractor
Retractor Set
5
27
OR - Retractor
Balfour Retractor Regular
1
8
OR - Retractor
DeBakey Balfour Retractor Deep
2
4
OR - Retractor
Grand/Henley Retractor
1
7
OR - Retractor
Henley Smooth Blades
1
3
OR - Retractor
Lighted Thorlakson Retractors
1
3
OR - Retractor
Retractor Anal Parks Set
1
7
OR - Retractor
Retractor Balfour Pedi Abdominal 3 ½”
1
6
OR - Retractors
St. Mark Retractor 9” Angled Lip Fiberoptic
2
3
OR - Retractors
Thorlakson Retractors
1
3
OR - TPX
TPX Set New
5
17
OR - Vascular
CV Set New
3
44
OR - Vascular
Thompson Bar
2
5
OR - Vascular
Thompson Blade Pan
2
19
OR - Vascular
Thompson Carotid Extras
1
6
OR - Vascular
Thompson Liver Blade Extras
1
8
OR - Vascular
Thompson Carotid Bar Set
2
3
OR - Vascular
Thompson Carotid Bar Pan
2
25
OR - Vascular
Vascular Extras
1
13
OR - Vascular
Carotid Bar with 1 Knuckle set
1
3
OR - Vascular
Scanlon Tunneler Set
3
5
OR -Vascular
Thompson Knuckles & Discs
2
32
OR/Clinic - GU
Vasectomy
5
11
OR-Vascular
CV Extra’s Set
1
14

APPENDIX B:

Routine Sets: Appendix B: Preventative Maintenance Schedule –

Service
Container Name
Number Of Set
Inst
Dental
Restoration
20
32
Dental
Hygiene
28
15
Dental
Dental Exam
43
5
Dental
Dental Hygiene Student
12
13
Dental
Straumann Implant Kit
10
1
Dental
Dental Lamb Extras
2
1
Dental
Dental Denture Adjustment Kits
30
8
Dental
Dental Cindy Extras
2
9
Dental
Straumann Novaloc
4
3
Dental
Dental Hygiene Perio
6
16
Dental
Dental Titanium Implant Scaler Kit K-1800
6
5
Dental
Lundy Extras
2
10
Dental
Nobel Implant Kit
2
3
Dental
Dental Garrison Ring Kit
4
3
Dental
Dental Student Extras
2
3
Dental
McGarvey Extras
2
3
Dental
Standard Dental Endo
3
28
Dental
BlisSonic Scaling Tips
12
3
Dental
Dental Endo Files 30mm
5
7
Dental
Dental Gates Glidden Kit
2
Dermatology
Derm Tray
8
9
ER
Facial Laceration Tray
8
6
OR - Cardiothoracic
Chest Set
2
38
OR - Cardiothoracic
Finochietto Pediatric Rib Spreader
2
1
OR - Emergency
Tracheostomy Set
2
45
OR - Eye
Cataract Extras
3
10
OR - Eye
Eye Enucleation Set
1
11
OR - General
Acufex Set
1
15
OR - General
Retractor Hill/Ferg Lighted (Rectal)
2
4
OR - General
New Hemorrhoid Bander Set
8
5
OR - General
Bowel Clamps
4
12
OR - General
Dall Miles
1
7
OR - General
Injector Capsule Tension Ring
1
1
OR - General
Liston Amputation Knife
1
1
OR - General
Neuro Osteotomes
1
11
OR - General
Amputation Pack
3
5
OR - General
Hemorrhoid Bander Set
2
6
OR - General
Henley Blades 1 1/2” (4 blades)
2
4
OR - General
Curette Neuro Short
1
8
OR - General
Table Top Plate Bender
1
1
OR - General
Trocar Irrigating Canula
1
4
OR - General
Biomet CTR Angled Heiss Set
2
2
OR - General
Gallbladder Set
2
12
OR - General
Medline Crossroads Cotton Trials 5-6, 7-8
1
2
OR - General
Thyroid Pan
1
27
OR - General
Unfolder Handpiece
1
1
OR - General Surgery
Long Instrument sets
4
30
OR - Laparoscopic
Laparoscopic TEP Extras
1
9
OR - Ortho
De Mayo Knee Positioner Base Case
3
1
OR - Ortho
Hand Set
4
36
OR - Ortho
New OR De Mayo Knee Positioner Acc Case
3
2
OR - Ortho
Knee Universal Patellar INST Tray
2
35
OR - Ortho
Stryker Fluted Headless Pins (x4)
5
4
OR - Ortho
Stryker Ortho Biters
1
19
OR - Ortho
Ortho Shaver Set
3
16
OR - Ortho
S&N GEN II Reamers 10-12-14MM
2
3
OR - Ortho
Elevators Key Ortho
1
5
OR - Ortho
Synthes Mini Frag Set (Back-up)
1
34
OR - Ortho
Stryker Backup Ortho Biters
7
64
OR - Ortho
Stryker Small Joint Inst.
2
15
OR - Ortho
Shukla Mini Screw Extraction Set
2
29
OR - Ortho
Shukla Univ. Screw Extraction Set
2
29
OR - Ortho
Bone Holding Forcep & Large Ankle Forcep
1
11
OR - Ortho
Cement Removal Instruments
1
32
OR - Ortho
Currettes (Ortho)
1
9
OR - Ortho
Synthes LCP Lg Fragment Inst Locking
1
57
OR - Ortho
Knee P/S Tibial Insert Trial Tray
2
24
OR - Ortho
Shukla Maxi Large Screw Extraction
2
38
OR - Ortho
Osteotomes
2
4
OR - Ortho
Bone Biopsy Instruments
1
6
OR - Ortho
Cannulated Screw Set Extras
1
13
OR - Ortho
Hand Osteotomes
1
5
OR - Ortho
Screw Removal Set
1
55
OR - Ortho
Steinmann Threaded Pin Set
1
60
OR - Ortho
Synthes D.C.P Plates
1
44
OR - Ortho
Synthes LC-DCP DCP Basic Inst Set Lg Frag
1
56
OR - Ortho
Synthes Mini Fragment Self Tapping
1
258
OR - Ortho
Craig Bone Biopsy Set
1
8
OR - Ortho
Ortho 6.5mm Cannulated Screw Set
1
137
OR - Ortho
Synthes LCP Large Fragment Plates
1
34
OR - Ortho
Synthes LCP Large Fragment Screw Set
1
543
OR - Ortho
Plantar Fasciotomy
1
6
OR – Ortho
Steinmann Plain Pin Set
1
60
OR – Ortho
Stryker Core Saber/PI Drive 2 Plus Drill
1
6
OR - Podiatry
Podiatry Set
6
57
OR - Podiatry
Arthrex Ankle Distractor
2
8
OR - Retractor
Henly Retractor Set
3
7
OR - Retractors
Hill Ferguson Retractors Set
4
3
OR - Retractors
St Marks 7 and 9” Retractors Fiberoptic
1
3
OR - Retractors
O’Sullivan O’Connor retractor w/4 Blades
1
5
OR - Vascular
Aortic Set
2
23
OR - Vascular
Mediastinoscopy
1
20
OR- Eye
Crawford Lacrimal Intubation Set
1
2
OR -Ortho
Allen shoulder Holder New
1
3
OR -Ortho
Synergy Broach Tray Hip
2
34
OR-Emergency
Cooley Sternotomy Spreader Adult Set
1
3
OR-Eye
Amo Ophthalmic Emerald Unfolder Delivery System
1
1
OR-GU
TUR Set
8
29
OR-GU
Circumcision Tray
2
10
OR-GU
Olympus Gyrus Set
4
4
OR-GU
Olympus Long Resectoscope Set
1
7
OR-GU
Olympus Urethrotome Blade & Knife
1
2
OR-GU
Olympus Urethrotome Set
1
7
OR-GU
Penile Dilators
1
7
OR-GU
Penile Prothesis BackUp Set
1
27
OR-GU
Penile Prosthesis
1
27
OR-GU
Prostatectomy
1
30
OR-GU
Sounds Lefort Urethral (10Fr-30Fr)
1
11
OR-GU
Sounds Van Buren Urethral
2
8
OR-Gyn
Abdominal Hysterectomy Set
1
32
OR-Gyn
D & C Set
2
26
OR-Gyn
Gyn LEEP Set
2
5
OR-Gyn
Hegar Uterine Dilator Set
1
11
OR-Ortho
Affiniti Humeral Bottom Tray (Tornier)
2
31
OR-Ortho
Affiniti Humeral Middle Tray (Tornier)
2
18
OR-Ortho
Affiniti Humeral Top Tray (Tornier)
2
21
OR-Ortho
Allen Shoulder Holder Old
1
2
OR-Ortho
Arthrex MIS Instrument Set New
2
4
OR-Ortho
Bone Spikes
1
5
OR-Ortho
Cannulated Screw Set Extras
1
12
OR-Ortho
Cutting blocks Langs Favorite
1
4
OR-Ortho
DeMayo Knee Positioner Base Case
3
1
OR-Ortho
Dr. Olswing’s Knee Extras
1
9
OR-Ortho
Hemi-Arthroplasty Set
2
40
OR-Ortho
Knee ACF Cut Blocks & Ream Fem Trials
2
18
OR-Ortho
Knee ACF Femoral Instrument Tray
2
22
OR-Ortho
Knee CR Tibial Insert Trial Tray
2
44
OR-Ortho
Knee Femoral Miscellaneous
2
16
OR-Ortho
Knee Holder
2
1
OR-Ortho
Knee P/S Ream Through Femoral Tray
2
13
OR-Ortho
Knee P/S Tibial Insert Trial Tray
2
24
OR-Ortho
Knee Tibial Instrument Tray
2
30
OR-Ortho
Knee Tibial Miscellaneous Tray
2
15
OR-Ortho
Ortho 6.5mm Cannulated Screw Set
1
138
OR-Ortho
R3 Hip Main Inst Tray
2
21
OR-Ortho
R3 Reamer Dome Tray
2
27
OR-Ortho
R3 Trial Shell Tray
2
21
OR-Ortho
S&N Small Joint Shaver
1
1
OR-Ortho
Shoulder Mini-Open Retractor
1
7
OR-Ortho
Shoulder Set
2
19
OR-Ortho
Small Joint Arthroplasty System
1
18
OR-Ortho
Steinmann Threaded Pin Set
1
60
OR-Ortho
Synergy Femoral Reamer Tray (Hip)
2
13
OR-Ortho
Synthes LCP Lg Fragment Inst Locking
1
57
OR-Ortho
Synthes LCP Sm. Frag Inst & Implant Set 1A
1
63
OR-Ortho
Synthes LCP Sm Frag Inst & Implant Set 1
1
612
OR-Ortho
Tornier Affiniti Glenoid Instrument Set
1
39
OR-Ortho
Total Shoulder Retractor
2
9
OR-Ortho
Total Shoulder Extras
2
6
OR-Ortho
Unipolar Trial
1
26
Or-Retractor
Charnley Amstutz Extras
1
3
OR-Retractor
Charnley Retractor Set
2
14
OR-Retractor
Henley Smooth Blades
1
3
OR-Retractor
Parsonnet Epicardial Retractor
1
2
OR-Retractor
Retractor Balfour Pedi Abdominal 1 ½”
1
2
OR-Vascular
AV Fistula Set
3
5
OR-Vascular
AV Sheath Tunneler
1
20
OR-vascular
Garrett Dilators x9
2
9
OR-Vascular
Kelly Wick Tunnler
1
14
OR-Vascular
Mediastinoscopy Extras
1
9
OR-Vascular
PV Sheath Tunneler
1
8
OR-Vascular/GU
Yasergil Appliers
3
2
Specials
SPR Lesion Set
7
10