Attach C- Pharmacy Service Design Guide.pdf
PDF 403 KB Posted
- Attached to
- Z2DA--618-26-600, Pharmacy Flooring Repair
- Solicitation number
- 36C26326B0003
About this file
This document is a VA Pharmacy Service Design Guide plate detailing specifications for specific pharmacy service areas, including Filling/Assembly Area, Filling/Assembly Carousel, Processing Area, Tube Station, and Restock Area for Crash Cart in an inpatient setting. The design guide provides comprehensive technical specifications across multiple systems, including architecture, interior design, communications, power, lighting, and HVAC requirements.
Key architectural details include a 9'-0" ceiling height with acoustical tiles, gypsum wallboard walls with paint, rubber flooring, and a single steel door with electronic entry. Communication systems feature data, telephone, electronic access, motion intrusion detection, and security surveillance. Power infrastructure includes both normal and emergency power sources. The document mandates adherence to VA Lighting Design Manual and VA HVAC Design Manual for specific technical guidelines, emphasizing the need for coordination with structural engineers for specialized equipment placement and potential slab modifications.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4.3.7 Filling/Assembly Area, Inpatient (PHIF1), Filling/Assembly Carousel, Inpatient (PHIF2), Processing Area, Inpatient (PHPA1), Tube Station (NT001), Restock Area, Crash Cart (PHRA1)
Room Data
ARCHITECTURE & INTERIOR DESIGN
Ceiling Type AT (Acoustical Ceiling Tile)
Ceiling Height 9’-0”
Wall Finish GWB (Gypsum Wallboard); P (Paint)
Base RF (Integral Base-4”)
Floor Finish RF (Rubber Flooring)
Slab Depression See Notes 2
Sound Protection See VA Interior Design Guide
Single Size Door, 3’-6” x 7’-0”(1066.8 mm Doors x 2133mm), Steel
Hardware Electronic Entry
Notes
1. For carousels, coordinate placement with structural engineer.
2. If high-density storage is used and a raised track is not selected, coordinate slab depression with structural engineer.
LIGHTING
General Requirement: Refer to VA Lighting Design Manual Chapter 4 Patient Areas Lighting Guidelines 4.2.18 Pharmacy for design approach and recommended luminaires.
POWER
Normal Yes
Emergency Yes
COMMUNICATIONS
Data Yes
Telephone Yes
Cable Television No
Duress Alarm No
Electronic Access Yes
Intercom No
Motion Intrusion Detection (MID) Yes
Public Access No
Security Surveillance Television (SSTV) Yes
Motion Sensor Ceiling
Clock Yes
Other No
HVAC
General Requirement: Refer to Inpatient Filling data sheet in the current version of the VA HVAC Design Manual for room temperatures, humidity range, room air change requirements, and pressurization.
APRIL 1, 2018
VHAMINPERAZE
Highlight
Accessibility Report
Filename:
PG 18-12 VA Pharmacy Guidelines_with-Appendix_2018.03.014.pdf
Report created by:
Organization:
[Enter personal and organization information through the Preferences > Identity dialog.]
Summary
The checker found no problems in this document.
Needs manual check: 0
Passed manually: 2
Failed manually: 0
Skipped: 1
Passed: 29
Failed: 0
Detailed Report
Document
Rule Name Status Description
Accessibility permission flag Passed Accessibility permission flag must be set
Image-only PDF Passed Document is not image-only PDF
Tagged PDF Passed Document is tagged PDF
Logical Reading Order Passed manually Document structure provides a logical reading order
Primary language Passed Text language is specified
Title Passed Document title is showing in title bar
Bookmarks Passed Bookmarks are present in large documents
Color contrast Passed manually Document has appropriate color contrast
Page Content
Rule Name Status Description
Tagged content Passed All page content is tagged
Tagged annotations Passed All annotations are tagged
Tab order Passed Tab order is consistent with structure order
Character encoding Passed Reliable character encoding is provided
Tagged multimedia Passed All multimedia objects are tagged
Screen flicker Passed Page will not cause screen flicker
Scripts Passed No inaccessible scripts
Timed responses Passed Page does not require timed responses
Navigation links Passed Navigation links are not repetitive
Forms
Rule Name Status Description
Tagged form fields Passed All form fields are tagged
Field descriptions Passed All form fields have description
Alternate Text
Rule Name Status Description
Figures alternate text Passed Figures require alternate text
Nested alternate text Passed Alternate text that will never be read
Associated with content Passed Alternate text must be associated with some content
Hides annotation Passed Alternate text should not hide annotation
Other elements alternate text Passed Other elements that require alternate text
Tables
Rule Name Status Description
Rows Passed TR must be a child of Table, THead, TBody, or TFoot
TH and TD Passed TH and TD must be children of TR
Headers Passed Tables should have headers
Regularity Passed Tables must contain the same number of columns in each row and rows in each column
Summary Skipped Tables must have a summary
Lists
Rule Name Status Description
List items Passed LI must be a child of L
Lbl and LBody Passed Lbl and LBody must be children of LI
Headings
Rule Name Status Description
Appropriate nesting Passed Appropriate nesting
Back to Top
| return to ch toc 3: |
| Page 14637: |
| Button 3: |
| Page 14670: |
File details come from the government source that posted it. Updated .