About this file

36C26318B0038 FINAL DRAWINGS Vol1_ 69 pages.pdf

View the file

Other files

File Type Posted
36C26318C0059-000.docx DOCX document
36C26318B0038-A00004000.docx DOCX document
36C26318B0038-A00004001.pdf PDF
36C26318B0038-A00004005.pdf PDF
36C26318B0038-A00004002.pdf PDF
36C26318B0038-A00004003.pdf PDF
36C26318B0038-A00004004.pdf PDF
36C26318B0038-A00003000.docx DOCX document
36C26318B0038-A00002000.docx DOCX document
36C26318B0038-A00001001.pdf PDF
36C26318B0038-A00001002.pdf PDF
36C26318B0038-A00001000.docx DOCX document
36C26318B0038-001.docx DOCX document
36C26318B0038-002.pdf PDF
36C26318B0038-004.pdf PDF
36C26318B0038-000.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADA

FD

NEW DOOR

Room name

A101

SIM

1 View Name 1/8" = 1'-0"

Name Elevation

VIEW TITLE

SECTION NOTING:

SIMILAR (SIM) CONDITION

TYPICAL (TYP) CONDITIONSHEET NUMBER

DETAIL NUMBER

FLOOR LEVEL INDICATING

1ST FLOOR @ ELEVATION

100'-0"

ROOM TAG

NORTH ARROW

EXISTING DOOR

? KEYNOTE SYMBOL

1t PARTITION TYPE

A.F.F.

1t

1'-0"

CEILING HEIGHT TAG

1i

T

DOOR

SIZE

1a

DOOR TAG

FIRE EXTINGUISHER

LOCATIONS

2' x 4' CEILING LED RECESSED

LIGHT

2' X 2' CEILING LED DIRECT/

INDIRECT LIGHT

6" APERTURE DOWNLIGHT

SURFACE MOUNTED CANOPY

LED LIGHT FIXTURE

4' FLUORESCENT LIGHT

4' LED STRIP, CHAIN HUNG

LIGHT

4' x 4' CEILING ACCESS

PANEL HATCH

WALL MOUNTED ADA PUSH BUTTON

2' X 1' SQUARE MECHANICAL

FIXTURE

2' X 2' SQUARE MECHANICAL

FIXTURE

FLOOR DRAIN

EXIT DIRECTION

A1

XXXX ELEVATION TAG

SHEET NUMBER

DETAIL NUMBER

1' X 1' SQUARE MECHANICAL

FIXTURE

12" ROUND MECHANICAL

FIXTURE

8" ROUND MECHANICAL

FIXTURE

CEILING MOUNTED CABINET

UNIT HEATER

100% DOCUMENTS -

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

15 Sunnen Drive, Suite 104 | St.

Louis, Missouri 63143

314.645.1132 Fax: 314.645.1173

www.imegcorp.com

855 Grandview Ave, Columbus, OH 43215

614-443-1178 www.dynamix-ltd.com

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

F

E

D

C

B

A

97 8654321

1 2 3 4 5 6 87 9

B

A

C

D

E

F

Department of Veterans Affairs

568-16-101

G-001

MTREF23 FEB 2018

113 Comanche Road Fort Meade, SD 57741

FT MEADE SPS/ENDOSCOPY

RENOVATION

LIST OF SHEETS AND SYMBOLS

113, SURGERY TOWER

Health Care System Black Hills Department of Veterans Affairs

DEPT. OF VETERANS AFFAIRS

VA PROJECT NUMBER:

OCULUS INC. PROJECT NUMBER:

VETERANS HEALTH CARE SYSTEM - BLACK HILLS

FT. MEADE SOUTH DAKOTA

SPS & ENDOSCOPY RENOVATION

VA 568-16-101

255 16-SD01.00

DESIGN SHEET INDEX

SHEET

NUMBER SHEET NAME

FP-000 FIRE PROTECTION LEGEND, ABBREVIATIONS, AND DETAILS

FP-100 PARTIAL BASEMENT FIRE PROTECTION PLAN

FP-101 FIRST FLOOR FIRE PROTECTION PLAN

FP-102 SECOND FLOOR FIRE PROTECTION PLAN

FPD-101 FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN

FPD-102 SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN

E-000 ELECTRICAL LEGENDS, ABBREVIATIONS, AND DETAILS

E-101 PARTIAL BASEMENT LIGHTING PLAN

E-111 FIRST FLOOR LIGHTING PLAN - AREA A

E-112 FIRST FLOOR LIGHTING PLAN - AREA B

E-113 FIRST FLOOR LIGHTING PLAN - AREA C

E-121 SECOND FLOOR LIGHTING PLAN - AREA A

E-124 PARTIAL FIRST FLOOR LIGHTING PLAN - PATIENT SERVICES

E-201 PARTIAL BASEMENT POWER PLAN

E-211 FIRST FLOOR POWER PLAN - AREA A

E-212 FIRST FLOOR POWER PLAN - AREA B

E-213 FIRST FLOOR POWER PLAN - AREA C

E-221 SECOND FLOOR POWER PLAN - AREA A

E-300 ELECTRICAL SINGLE LINE DIAGRAM

E-301 ELECTRICAL PANEL SCHEDULES

E-400 ELECTRICAL DETAILS

E-401 ELECTRICAL DETAILS

ED-101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN

ED-102 SECOND FLOOR ELECTRICAL DEMOLITION PLAN

T-000 TECHNOLOGY LEGEND AND ABBREVIATIONS

T-001 TECHNOLOGY DETAILS

T-101 PARTIAL BASEMENT TECHNOLOGY PLAN

T-111 FIRST FLOOR TECHNOLOGY PLAN - AREA A

T-112 FIRST FLOOR TECHNOLOGY PLAN - AREA B

T-121 SECOND FLOOR TECHNOLOGY PLAN - AREA A

T-400 TECHNOLOGY ROOM RACK ELEVATIONS

T-501 TECHNOLOGY DETAILS

TD-101 FIRST FLOOR TECHNOLOGY DEMOLITION PLAN

TD-102 SECOND FLOOR TECHNOLOGY DEMOLITION PLAN

DESIGN SHEET INDEX

SHEET

NUMBER SHEET NAME

S-000 GENERAL NOTES

S-101 BASEMENT NEW CONSTRUCTION AREA

S-111 FIRST FLOOR PLAN - AREA A

S-112 FIRST FLOOR PLAN - AREA B

S-113 EXISTING FIRST FLOOR AND SECOND FLOOR PLAN - AREA C

S-121 FLOOR INFILL SPECIAL PROCEDURE ROOM 222

S-122 SPECIAL PROCEDURE AND ENDOSCOPY - CEILING MOUNTED

EQUIPMENT

S-300 CONCRETE DETAILS

S-301 CONCRETE DETAILS

S-302 SECTIONS AT SPECIAL PROCEDURE ROOM 215 INFILL

M-000 HVAC LEGENDS, ABBREVIATIONS, AND DETAILS

M-101 PARTIAL BASEMENT HVAC DUCT PLAN

M-111 FIRST FLOOR HVAC DUCT PLAN - AREA A

M-112 FIRST FLOOR HVAC DUCT PLAN - AREA B

M-113 FIRST FLOOR HVAC DUCT PLAN - AREA C

M-121 SECOND FLOOR HVAC DUCT PLAN - AREA A

M-124 PARTIAL FIRST FLOOR HVAC DUCT PLAN - PATIENT SERVICES

M-201 PARTIAL BASEMENT HVAC PIPING PLAN

M-211 FIRST FLOOR HVAC PIPING PLAN - AREA A

M-212 FIRST FLOOR HVAC PIPING PLAN - AREA B

M-213 FIRST FLOOR HVAC PIPING PLAN - AREA C

M-221 SECOND FLOOR HVAC PIPING PLAN - AREA A

M-300 HVAC SCHEDULES

M-400 HVAC DETAILS

M-401 HVAC DETAILS

M-402 HVAC SCHEMATIC

M-403 HVAC SCHEMATIC

M-404 HVAC SECTIONS

M-500 HVAC CONTROLS

MD-101 FIRST FLOOR HVAC DEMOLITION PLAN

MD-102 SECOND FLOOR HVAC DEMOLITION PLAN

P-000 PLUMBING LEGEND, ABBREVIATIONS, AND DETAILS

P-111 FIRST FLOOR UNDERSLAB - AREA A

P-112 FIRST FLOOR UNDERSLAB - AREA B

P-113 FIRST FLOOR UNDERSLAB - AREA C

P-201 PARTIAL BASEMENT PLUMBING PLAN

P-211 FIRST FLOOR PLUMBING PLAN - AREA A

P-212 FIRST FLOOR PLUMBING PLAN - AREA B

P-213 FIRST FLOOR PLUMBING PLAN - AREA C

P-214 BELOW SECOND FLOOR PLUMBING PLAN - AREA A

P-221 SECOND FLOOR PLUMBING PLAN - AREA A

P-224 PARTIAL FIRST FLOOR PLUMBING PLAN - PATIENT SERVICES

P-321 SECOND FLOOR MEDICAL GAS PLAN - AREA A

P-400 PLUMBING STACKS - FIRST FLOOR

P-401 PLUMBING STACKS - SECOND FLOOR

P-402 PLUMBING RISERS - FIRST FLOOR

P-403 PLUMBING RISERS - SECOND FLOOR

P-500 PLUMBING SCHEDULES

P-501 PLUMBING DETAILS

PD-101 FIRST FLOOR PLUMBING DEMOLITION PLAN

PD-102 SECOND FLOOR PLUMBING DEMOLITION PLAN

DESIGN SHEET INDEX

SHEET

NUMBER SHEET NAME

G-001 LIST OF SHEETS AND SYMBOLS

G-002 STANDARD ABBREVIATIONS

G-100 LIFE SAFETY PLAN - LEVEL 1 & BASEMENT LEVEL

G-101 LIFE SAFETY PLAN - LEVEL 2 AND PENTHOUSE

AD-100 BASEMENT DEMOLITION PLAN

AD-101 FIRST FLOOR DEMOLITION PLAN

AD-102 SECOND FLOOR DEMOLITION PAN

AD-103 DEMOLITION REFLECTED CEILING PLAN @ EXISTING ICU

A-001 FIRST FLOOR OVERALL PLAN - NEW CONSTRUCTION

A-002 SECOND FLOOR OVERALL PLAN - NEW CONSTRUCTION

A-101 PARTIAL BASEMENT PLAN

A-111 FIRST FLOOR PLAN - AREA A

A-113 FIRST FLOOR PLAN - AREA B

A-115 FIRST FLOOR PLAN - AREA C

A-121 SECOND FLOOR PLAN - AREA A

A-201 PARTIAL BASEMENT REFLECTED CEILING PLAN

A-211 FIRST FLOOR REFLECTED CEILING PLAN - AREA A

A-212 FIRST FLOOR REFLECTED CEILING PLAN - AREA B

A-213 FIRST FLOOR REFLECTED CEILING PLAN - AREA C

A-221 SECOND FLOOR REFLECTED CEILING PLAN - AREA A

A-224 PARTIAL PLANS @ EXISITING FIRST FLOOR PATIENT SERVICES

DEDUCT ALTERNATE #2

A-301 PARTIAL EXTERIOR ELEVATIONS

A-401 LARGE-SCALE TOILET PLANS

A-403 SOILED ELEVATOR PLAN AND SECTIONS

A-404 CLEAN ELEVATOR PLAN AND SECTIONS

A-501 EXTERIOR DETAILS - DEDUCT ALTERNATE 1

A-502 EXTERIOR DETAILS - DEDUCT ALTERNATE 1

A-503 EXTERIOR DETAILS

A-504 INTERIOR DETAILS

A-505 INTERIOR DETAILS

A-506 INTERIOR DETAILS

A-507 INTERIOR DETAILS

A-508 INTERIOR DETAILS

A-509 FIRST FLOOR INTERIOR ELEVATIONS

A-510 SECOND FLOOR INTERIOR ELEVATIONS

A-511 SECOND FLOOR INTERIOR ELEVATIONS

A-515 ELEVATOR DETAILS

A-601 DOOR DETAILS AND SCHEDULE

A-800 PARTITION TYPE LEGEND

A-900 CART WASH DETAILS

QH-001 FIRST FLOOR EQUIPMENT REFERENCE PLAN

QH-002 SECOND FLOOR EQUIPMENT REFERENCE PLAN

QH-100 OVERALL EQUIPMENT SCHEDULE

QH-101 OVERALL EQUIPMENT SCHEDULE

QH-102 OVERALL EQUIPMENT SCHEDULE

QH-103 OVERALL EQUIPMENT SCHEDULE

QH-211 SPS EQUIPMENT REFERENCE PLAN - DECONTAM

QH-212 SPS EQUIPMENT REFERENCE PLAN - STERILE

QH-221 SPECIAL PROCEDURES EQUIPMENT REFERENCE PLAN

QH-222 ENDOSCOPY EQUIPMENT REFERENCE PLAN

I-001 FINISH SCHEDULES

I-002 FINISH SCHEDULES

I-111 FIRST FLOOR FINISH PLAN - AREA A

I-113 FIRST FLOOR FINISH PLAN - AREA B

I-115 SECOND FLOOR FINISH PLAN - AREA A

ARCHITECTURAL LEGEND

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAMA AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION

AB ANCHOR BOLT

ABC AGGREGATE BASE COURSE

AC ASBESTOS CEMENT OR ASPHALTIC

CONCRETE

ACI AMERICAN CONCRETE INSTITUTE

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADC AUTOMATIC DOOR CLOSER

ADDL ADDITIONAL

ADDN ADDITION

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR

ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGA AMERICAN GAS ASSOCIATION

AGC ASSOCIATED GENERAL CONTRACTORS

AGGR AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF

ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL

CONSTRUCTION

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AMP AMPERE

AMT AMOUNT

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS

INSTITUTE

ANT ANTENNA

APA AMERICAN PLYWOOD ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

APT APARTMENT

AR AS REQUIRED

ARCH ARCHITECT

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL

INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASPH ASPHALT

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING

AND MATERIALS

ATCH ATTACHMENT

ATM AUTOMATIC TELLER MACHINE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AVE AVENUE

AVG AVERAGE

AW ACID WASTE

AWI ARCHITECTURAL WOODWORKING

INSTITUTE

AWPA AMERICAN WOOD PRESERVERS'

ASSOCIATION

AWS AMERICAN WELDING SOCIETY

AWT ACOUSTICAL WALL TREATMENT

B LABEL CLASS B DOOR

B PL BASE PLATE

BALC BALCONY

BAT BATTEN

BB BULLETIN BOARD

BD BOARD

BD FT BOARD FEET (FOOT)

BEV BEVEL

BHMA BUILDER'S HARDWARE

MANUFACTURER'S ASSOCIATION

BI FLD DR BIFOLDING DOORS

BITUM BITUMINOUS

BKG BACKING

BLD BUILD

BLDG BUILDING

BLKT BLANKET

BLVD BOULEVARD

BM BEAM OR BENCHMARK

BOT BOTTOM

BR BEDROOM

BRCG BRACING

BRDG BRIDGING

BRDG JST BRIDGING JOIST

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BRZ BRONZE

BSMT BASEMENT

BTWN BETWEEN

BU BUSHEL

BUR BUILT-UP ROOFING

C CELSIUS CHANNEL

C CHANNEL CELSIUS

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

C TO C CENTER TO CENTER

CAB CABINET

CAC CEILING ATTENUATION CLASS

CB CATCH BASIN OR CORNER BEAD

CBB CEMENTITIOUS (BACKER) BOARD

CC CUBIC CENTIMETER

CCTV CLOSED CIRCUIT TELEVISION

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS OR

CONTRACT DOCUMENTS

CEM CEMENT

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR

FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER

INSTALLED

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY OR CORNER

GUARD

CGSFU CERAMIC GLAZED STRUCTURAL

FACING UNITS

CH BD CHALKBOARD

CHEM CHEMICAL

CHFR CHAMFER

CHK CHECK

CI CAST IRON

CIP CAST-IN-PLACE

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT OR CONTROL

JOINT

CL CENTER LINE

CLDG CLADDING

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

cm² SQUARE CENTIMETER cm ³ CUBIC CENTIMETER

CM CONSTRUCTION MANAGEMENT

CMU CONCRETE MASONRY UNIT

CNR CORNER

CNTR COUNTER

CO CARBON MONOXIDE, CERTIFICATE

OF OCCUPANCY, CLEANOUT, OR

COMPANY

CO� CARBON DIOXIDE

COL COLUMN

COM COMMON

COMB COMBINATION, COMBINED

COMM COMMUNICATION

COMP COMPONENT

CONC CONCRETE

CONC FLR CONCRETE FLOOR

COND CONDENSER OR CONDITION

CONF CONFERENCE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CORR CORRIDOR

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CPT CARPET

CRS COLD ROLLED STEEL

CRSI CONCRETE REINFORCING STEEL

INSTITUTE

CSB CONCRETE SPLASH BLOCK

CSG CASING

CSI CONSTRUCTION SPECIFICATIONS

INSTITUTE

CSK COUNTER SUNK

CSMT CASEMENT

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTG COATING

CTR CENTER CONTOUR

CTRL CONTROL

CTV CABLE TELEVISION

CU COPPER C

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CURT CURTAIN

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL DIAGRAM

DIAG DIAGRAM DIAGONAL

DIFF DIFFERENCE OR DIFFUSER

DIM DIMENSION

DIR DIRECTION

DISP DISPENSER

DIST DISTANCE

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DOZ DOZEN

DR DOOR, DRAIN, DRESSING ROOM, OR

DRIVE

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DS DOWNSPOUT

DSGN DESIGN

DW DISHWASHER

DWG DRAWING

DWTR DUMBWAITER

E EAST

E LABEL CLASS E DOOR

EA EACH

EFF EFFICIENCY

EFS EXTERIOR FINISH SYSTEM

EIFS EXTERIOR INSULATION AND FINISH

SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRIC

ELEC DR OP ELECTRIC DOOR OPENER

ELEV ELEVATOR

EMER EMERGENCY

EMER SHR EMERGENCY SHOWER

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION

AGENCY

EPDM ETHYLENE PROPYLENE DIENE

MONOMER

EPO EMERGENCY POWER OFF

EPS EXPANDED POLYSTYRENE BOARD

(INSULATION)

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ERD EXISTING ROOF DRAIN

ESC ESCAPE OR ESCUTCHEON

ESCAL ESCALATOR

ESMT EASEMENT

ESP ESPECIALLY

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXP BT EXPANSION BOLT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR

EXTINGUISHER

EXT GR EXTERIOR GRADE

F FAHRENHEIT OR FEMALE

FA FIRE ALARM

FAB FABRIC

FAC FACTOR

FACIL FACILITY

FAS FASCIA

FAS BD FASCIA BOARD

FCO FLOOR CLEANOUT

FCTY FACTORY

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF&E FURNITURE, FIXTURE, AND

EQUIPMENT

FH FLAT HEAD OR FLAT HEAD SCREWS

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIG FIGURE

FIL FILLET

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIN WD FINISH WOOD

FIXT FIXTURE

FL FLOORLINE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FM FACTORY MUTUAL

FM-G FACTORY MUTUAL GLOBAL

FO FINISHED OPENING

FOC FACE OF CONCRETE OR FACE OF

CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB OR FACE OF STUD

FOUNT FOUNTAIN

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT, OR

FRAME

FR SNK FLUSHING RIM SINK

FREQ FREQUENCY

FRMG FRAMING

FRP FIBER REINFORCED POLYESTER OR

FIBERGLASS REINFORCED PLASTIC

FRZ FREEZER

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET OR FOOT

FTG FOOTING

FURG FURRING

FURN FURNISH OR FURNITURE

FUT FUTURE

FWC FABRIC WALLCOVERING

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GDR GUARD RAIL

GEN GENERAL OR GENERATOR

GFRC GLASS-FIBER-REINFORCED

CONCRETE

GFRG GLASS-FIBER-REINFORCED GYPSUM

GFRP GLASS-FIBER-REINFORCED PLASTIC

GI GALVANIZED IRON

GL GLASS

GL BLK GLASS BLOCK

GLU LAM GLUED LAMINATED WOOD

GR FL GROUND FLOOR

GRAN GRANITE

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

GT GROUT

GUAR GUARANTEE

GUT GUTTER

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H HIGH

H PLAM HIGH PRESSURE PLASTIC LAMINATE

HAZ MAT HAZARDOUS MATERIALS

HB HOSE BIBB

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD DOOR

HDBD HARDBOARD

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HM HECTOMETER

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HIGH PRESSURE OR HORSEPOWER

HQ HEADQUARTERS

HS HEAT-STRENGTHENED (GLASS) OR

HIGH STRENGTH

HSE HOUSE

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

HVY HEAVY

HW HOT WATER

HYD HYDRANT

HYDR HYDRAULIC

I INTERSTATE (HIGHWAY) OR MOMENT

OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE DIAMETER,

OR INTERIOR DESIGN

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

IRMA INVERTED ROOF MEMBRANE

ASSEMBLY

IWH INSTANTANEOUS WATER HEATER

JAN JANITOR

J-BOX JUNCTION BOX

KD KILN DRIED OR KNOCKED DOWN

KIT KITCHEN

KO KNOCKOUT

KPL KICKPLATE

L ANGLE

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE

LHR LEFT HAND REVERSE LATENT HEAT

RATIO

LIB LIBRARY

LIN LINEAR

LINO LINOLEUM

LIQ LIQUID

LKR LOCKER

LKR RM LOCKER ROOM

LKWASH LOCKWASHER

LL LEAD LINED

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMST LIMESTONE

LNDSCP LANDSCAPE

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

LVD LOUVERED

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

LWIC LIGHTWEIGHT INSULATING CONCRETE

LYR LAYER

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION

SYSTEM

MAX MAXIMUM

MB MACHINE BOLT

MCB METAL CORNER BEAD

MD DECK

ME MECHANICAL ENGINEER

MEAS MEASURE

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL MEDIUM

MED MEDIUM MEDICAL

MEK METHYL ETHYL KETONE

MEL MELAMINE

MEMB MEMBRANE

MEMO MEMORANDUM

MEZZ MEZZANINE

MF MILL FINISH

MFD MANUFACTURED

MFG MANUFACTURING

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MGT MANAGEMENT

MH MANHOLE

MIC MICROPHONE

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM MINUTE

MIN MINUTE MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MIT MITER

MKR MARKER

ML METAL LATH

MLDG MOLDING (MOULDING)

MLWK MILLWORK

mm MILLIMETER

MO MASONRY OPENING OR MOTOR

OPERATED

MOD MODEL, MODIFY OR MODULE

MOD BIT MODIFIED BITUMEN

MON MONITOR

MOPR MOP RACK

MR MOISTURE RESISTANT

MS MACHINE SCREW OR MOP SINK

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MW MICROWAVE

MWP MEMBRANE WATERPROOFING

N NORTH

NA NOT APPLICABLE

NAAMM NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL

MANUFACTURERS

NAT NATURAL

NATL NATIONAL

NC NOISE CRITERIA

NCOMBL NONCOMBUSTIBLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NEUT NEUTRAL

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NR NOISE REDUCTION

NRC NOISE REDUCTION COEFFICIENT

NRCA NATIONAL ROOFING CONTRACTORS

ASSOCIATION

NRP NONREMOVABLE

NS NARROW STILE

NUM NUMERAL

O/O OUT TO OUT

O OXYGEN

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCC OCCUPY

OCT OCTAGON

OD OUTSIDE DIAMETER OUTSIDE

DIMENSION

OD OUTSIDE DIMENSION OUTSIDE

DIAMETER

OF/CI OWNER FURNISHED/CONTRACTOR

INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER

INSTALLED

OH OVERHANG

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

OPT OPTIONAL

OR OPERATING ROOM OR OUTSIDE

RADIUS

ORD ORDNANCE OR OVERFLOW ROOF

DRAIN

ORG ORGANIC

ORIG ORIGINAL

ORN ORNAMENTAL

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINSTRATION

OUT OUTLET

OZ OUNCE

PAR PARALLEL OR PARAPET

PARA PARAGRAPH

PART PARTIAL

PAT PATTERN

PB PUSHBUTTON

PBD PARTICLEBOARD

PC PIECE, POLYCARBONATE OR

PORTLAND CEMENT

PCA PORTLAND CEMENT ASSOCIATION

PCC PRECAST CONCRETE

PCCP CONCRETE PAVEMENT

PCD PAPER CUP DISPENSER

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PED PEDESTAL

PEN PENETRATE

PEND PENDANT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PGBD PEGBOARD

PHAR PHARMACY

PHOTO PHOTOGRAPH

PHS PHILLIPS HEAD SCREW

PKG PACKAGE

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER OR PLASTIC

PLBG PLUMBING

PLYWD PLYWOOD

PMTL PAINTED METAL

PNEU PNEUMATIC

PNL PANEL

PO POST OFFICE PURCHASE ORDER

PO PURCHASE ORDER POST OFFICE

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PREP PREPARATION

PRESS PRESSURE

PREV PREVIOUS

PRKG PARKING

PRMLD PREMOLDED

PROJ PROJECT

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, OR

PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE (PLASTIC)

PVG PAVING

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QRY QUARRY

QT QUARRY TILE

QTB QUARRY TILE BASE

QTF QUARRY TILE FLOOR

QTR QUARTER

QTY QUANTITY

QUAD QUADRANT

QUAL QUALITY

R RADIUS OR RISER

RA RETURN AIR

RAD RADIATOR

RB RESILIENT BASE OR RUBBER BASE

RB HK ROBE HOOK

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

RCVR RECEIVER

RD ROAD OR ROOF DRAIN

REC RECESSED

RECD RECEIVED

RECPT RECEPTACLE

RECT RECTANGLE

REF REFERENCE OR REFRIGERATOR

REFR REFRACTORY REFRIGERATION

REFR REFRIGERATION REFRACTORY

REG REGISTER

REINF REINFORCE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

RET RETURN

REV REVISION

RF RADIO FREQUENCY

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHR RIGHT HAND REVERSE

RHWS ROUND HEAD WOOD SCREW

RL ROOF LEADER

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RS ROUGH SAWN

RT RIGHT

RV ROOF VENT

RVS REVERSE

RWD REDWOOD

RWL RAIN WATER LEADER

SA SUPPLY AIR

SALV SALVAGE

SAMP SAMPLE

SAN SANITARY

SAT SUSPENDED ACOUSTICAL TILE

SATC SUSPENDED ACOUSTICAL TILE

CEILING

SB SPLASH BLOCK

SBS STYRENE BUTADIEN STYRENE

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID

CORE

SCH SCHOOL

SCHED SCHEDULE

SCHEM SCHEMATIC

SCP SCUPPER

SCRN SCREEN

SCT STRUCTURAL CLAY TILE

SCWD SOLID CORE WOOD DOOR

SD SHOP DRAWINGS, SMOKE DETECTOR,

OR SOAP DISPENSER;

SDG SIDING

SECT SECTION

SEG SEGMENT

SEL SELECT

SEP SEPARATE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGD SLIDING GLASS DOOR

SGL SINGLE

SHR SHOWER

SHR HD SHOWER HEAD

SHRD SHOWER DRAIN

SHT SHEET

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SJI STEEL JOIST INSTITUTE

SK SKETCH

SKLT SKYLIGHT

SLD WDW HORIZONTAL SLIDING WINDOW

SLDG SLIDING

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

SND SANITARY NAPKIN DISPENSER

SND INS SOUND INSULATION

SNDU SANITARY NAPKIN DISPOSAL UNIT

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SPLY SUPPLY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SANITARY SEWER OR SERVICE SINK

SST STAINLESS STEEL

ST STAIRS OR STREET

STC SOUND TRANSMISSION CLASS

STD STANDARD

STIF STIFFENER

STL JST STEEL JOIST

STL LNTL STEEL LINTEL

STL PL STEEL PLATE

STL RF DK STEEL ROOF DECK

STL TB STEEL TUBE

STL TR STEEL TRUSS

STNLS STAINLESS

STOR STORAGE

STR STRINGERS

STRUCT STRUCTURAL

STRUCT STL STRUCTURAL STEEL

SUB SUBSTITUTE

SURF SURFACE

SUSP SUSPEND

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SW SWITCH

SWDR SWING DOOR

SYM SYMBOL

SYNTH SYNTHETIC

SYS SYSTEM

T TREAD

T&G TONGUE AND GROOVE

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL BAR

TCA TILE COUNCIL OF AMERICA

TCP TELEPHONE CONTROL PANEL TEMPERATURE CONTROL

PANEL; TRAFFIC CONTROL PLAN

TD TOWEL DISPENSER

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPERATURE OR TEMPORARY

TER TERRAZZO

THD THREAD

THERM THERMAL

THK THICKNESS

THRES THRESHOLD

THRU THROUGH

THRUOUT THROUGHOUT

TK BD TACKBOARD

TMPD TEMPERED

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TO TOP OF ___

TO FDN TOP OF FOUNDATION

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPH TOILET PAPER HOLDER

TR TOWEL RACK

TRANS TRANSOM

TRANS WD FINTRANSPARENT WOOD FINISH

TRTD TREATED

TS TENSILE STRENGTH OR TUBE STEEL

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U HEAT TRANSFER COEFFICIENT

UC UNDERCUT

UCD UNDERCUT DOOR

UGND UNDERGROUND

UL UNDERWRITERS LABORATORIES

ULT ULTIMATE

UNFIN UNFINISH

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UR URINAL

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VAC VACUUM

VAR VARIES

VCT VINYL COMPOSITION TILE VITRIFIED CLAY TILE

VEH VEHICLE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VFAT VINYL FACED ACOUSTICAL TILE

VIC VICINITY

VID VIDEO

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC COMPOUND

VOL VOLUME

VOLT VOLTAGE

VP VENEER PLASTER

VR VAPOR RETARDER

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

VWF VINYL WALL FABRIC

W WIDE OR WEST

W/ WITH

W/O WITHOUT

WARR WARRANTY

WBL WOOD BLOCKING

WC WALL COVERING OR WATER CLOSET

WC WL HNG WATER CLOSET, WALL HUNG

WCHR WATER CHILLER

WCL WL MTD WATER COOLER, WALL HUNG

WD WOOD

WDW WINDOW

WF WIDE FLANGE

WFAB WALL FABRIC

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

WHSE WAREHOUSE

WLD WELDED

WM WIRE MESH

WP WATERPROOFING

WPD WATER PRESSURE DROP

WPM WATERPROOF MEMBRANE

WR WEATHER RESISTANT

WS WEATHERSTRIP

WSCT WAINSCOT

WT WEIGHT

WWF WELDED WIRE FABRIC

X BRACE CROSS BRACE

XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)

YD YARD

YR YEAR

100% DOCUMENTS -

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

15 Sunnen Drive, Suite 104 | St.

Louis, Missouri 63143

314.645.1132 Fax: 314.645.1173

www.imegcorp.com

855 Grandview Ave, Columbus, OH 43215

614-443-1178 www.dynamix-ltd.com

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

F

E

D

C

B

A

97 8654321

1 2 3 4 5 6 87 9

B

A

C

D

E

F

Department of Veterans Affairs

568-16-101

G-002 AuthorChecker23 FEB 2018

113 Comanche Road Fort Meade, SD 57741

FT MEADE SPS/ENDOSCOPY

RENOVATION

STANDARD ABBREVIATIONS

113, SURGERY TOWER

95'

87'

DN

UP

UP

19'

B, BUSINESS

NOT IN SCOPE

S-1, STORAGE

TOTAL EXIT CAPACITY =

TOTAL OCCUPANT LOAD =

LEVEL 1 (15,342 SF. W/O COURT)

V A

ACTUAL DOOR REMOTENESS = 98' - 11 3/4"

1/3 THE DIAGONAL DISTNACE = 68'-6"

DIAGONAL DISTANCE = 205' - 5"

DN

NOT IN SCOPE

INTERIOR LIGHT WELL

198' H E

BUILDING CODE DATA:

BUILDING CODE AGENCY/JURISDICTION:

BUILDING CODE:

BUILDING HEIGHT (ACTUAL; ALLOWABLE)

TOTAL # OF FLOORS; TOTAL ALLOWED:

TOTAL # OF FLOORS ABOVE GRADE:

BUILDING AREA (ACTUAL; ALLOWABLE):

PROJECT/BUILDING DATA:

NEW CONSTRUCTION TYPE:

EXIST. CONSTRUCTION TYPE:

REQUIRED FIRE RESISTANCE RATINGS:

STRUCTURAL FRAME:

BEARING WALLS (EXTERIOR; INTERIOR):

NONBEARING WALLS (EXTERIOR; INTERIOR):

FLOOR CONSTRUCTION:

ROOF CONSTRUCTION:

OCCUPANCY DATA:

MIXED USE/SEPARATED

OCCUPANCY GROUP(S)(NFPA 101 6.1.14.3):

EXIT CAPACITY FACTORS:

(NFPA 101 TABLE 7.3.3.1)

TRAVEL DISTANCE LIMITATIONS:

GROUP I (NFPA TABLE A7.6)

GROUP B (NFPA TABLE A7.6)

GROUP S, LOW HAZARD (NFPA TABLE A7.6)

ALL OTHER OCCUPANCIES:

FIRE PROTECTION SYSTEMS:

AUTOMATIC SPRINKLERS:

FIRE DEPARTMENT STANDPIPES:

FIRE ALARM SYSTEM:

SUPERVISION:

PORTABLE FIRE EXTINGUISHERS:

SMOKE AND HEAT DETECTION DEVICES:

OCCUPANT NOTIFICATION:

SMOKE MANAGEMENT SYSTEM:

NA

VA GUIDELINES AND STANDARDS

2015 NFPA 101 LIFE SAFETY CODE (NFPA 101)

2015 NFPA 220 STANDARD ON TYPES OF BUILDING

CONSTRUCTION (NFPA 220)

2002 NFPA 101B CODE FOR MEANS OF EGRESS FOR BUILDINGS

AND STRUCTURES (NFPA 101B)

2015 NFPA 5000 BUILDING CONSTRUCTION AND SAFETY YCODE

(NFPA 5000)

2013 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHER

31'-4"; 180'-0" (NFPA 5000 TABLE 7.4.1)

2-STORIES W/ BASEMENT; 12-STORIES (NFPA 5000 TABLE 7.4.1)

2-STORIES

26,891 SF; UNLIMITED (UL) (NFPA 5000 TABLE 7.4.1)

TYPE II-FR - (222), FIRE RESISTIVE, NON-COMBUSTIBLE

(NFPA 101 TABLE 18.1.6.1)

TYPE II-FR - (222)(NFPA 101 TABLE 19.1.6.1)

2-HOURS (NFPA 220 TABLE 4.1.1)

2-HOURS; 2 HOURS (NFPA 220 TABLE 4.1.1)

0-HOURS; 0 HOURS (NFPA 220 TABLE 4.1.1)

2-HOURS (NFPA 220 TABLE 4.1.1)

1-HOURS (NFPA 220 TABLE 4.1.1)

I-2. INSTITUTIONAL, PROCEDURE/RECOVERY ROOMS, BUILDING

113 LEVEL 2. (NFPA 101 6.1.5) B - BUSINESS, BUILDING 113

BASEMENT AND FIRST FLOOR NEW ADDITION (NFPA 101 6.1.11)

0.20 IN/OCC FOR HORIZONTAL EGRESS ELEMENTS

0.30 IN/OCC FOR VERTICAL EGRESS ELEMENTS

COMMON: TRAVEL: DEAD-END:

100 FEET 200 FEET 30 FEET

100 FEET 300 FEET 50 FEET

NO REQ. NO REQ. NO REQ.NA

FULLY SPRINKLERED (NFPA 101 18.3.5)(NFPA 13)

YES (NFPA 5000 55.4)(NFPA 14)

YES (NFPA 72)

YES (NFPA 5000 55.3.2)(NFPA 13)(NFPA 72)

YES; TRAVEL DISTANCE: 75 FT MAX. (NFPA 10 2013 TABLE

6.2.1.1)(NFPA 18.3.5.12)

YES (NFPA 5000 55.2.2.10)(NFPA 101 18.3.4.5)(NFPA 72)

YES (NFPA 5000 55.2.3)(NFPA 101 18.3.4.3.1)(NFPA 72)

NO

PROJECT SUMMARY:

STERILE PROCESSING SERVICE, SPECIAL PROCEDURES AND ENDOSCOPY AREAS RENOVATION.

THESE DRAWINGS INCLUDE THE INFORMATION AND SPECIFICATIONS FOR THE ARCHITECTURAL

SCOPE OF WORK. THE MECHANICAL, ELECTRICAL, PLUMBING, AND LIFE SAFETY DRAWINGS AND

SPECIFICATIONS SHALL BE SUBMITTED BY THE DESIGN-BUILD SUB CONTRACTORS.

PATH OF TRAVEL (FEET)

1-HOUR RATED

2-HOUR RATED

VOICE/ALARM SYSTEM THROUGHOUT

STANDPIPE HOSE OUTLET

EXIT FLOW

EXIT CAPACITY

SMOKE DETECTOR

(SEE ELECTRICAL)

V A

COMMON PATH OF TRAVEL (FEET)

START OF TRAVEL

EXIT SIGN

(SEE ELECTRICAL)

SMOKE PARTITION PORTABLE

FIRE EXTINGUISHER

2-HOUR BUILDING FIRE SEPARATION

SMOKE BARRIER (1 HOUR RATED)

HORIZONTAL EXITHE

1. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE

OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS

THAN 32 INCHES. THE HEIGHT OF DOORS SHALL NOT BE LESS THAN 80 INCHES.

2. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE

WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ALL

EGRESS DOORS TO HAVE PANIC HARDWARE. PANIC HARDWARE SHALL NOT

REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FORCE

REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.

3. THE MEANS OF EGRESS, AND EXIT DISCHARGE, SHALL BE ILLUMINATED AT ANY

TIME THE BUILDING IS OCCUPIED WITH A LIGHT INTENSITY OF NOT LESS THAN 1

FOOT-CANDLE AT THE WALKING SURFACE LEVEL.

4. THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT

ALL TIMES. NO STORAGE IS PERMITTED IN ANY EGRESS PATHS.

5. EXISTING FIRE EXTINGUISHERS ARE LOCATED THROUGHOUT THE EXISTING

BUILDING. LOCAL AUTHORITY TO REVIEW AND/OR APPROVE ALL EXISTING

LOCATIONS. ALL NEW PROPOSED F.E. LOCATIONS ARE DETERMINED BY NFPA 10

AND/OR BY THE DIRECTION OF THE LOCAL AUTHORITY.

6. PORTABLE FIRE EXTINGUISHER CABINETS TO BE SEMI-RECESSED, WITH A 2 1/2"

PROJECTION AND AN INSIDE BOX DIMENSION OF AT LEAST 24"H x 9 1/2"W x 6"D, CAPABLE OF ACCOMMODATING A 10LB, DRY CHEMICAL A/B/C TYPE FIRE

EXTINGUISHER.

NOT IN SCOPE (BASEMENT)

TOTAL EXIT CAPACITY =

TOTAL OCCUPANT LOAD =

BASEMENT LEVEL (790 SF.)

V A

43'

100% DOCUMENTS -

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

15 Sunnen Drive, Suite 104 | St.

Louis, Missouri 63143

314.645.1132 Fax: 314.645.1173

www.imegcorp.com

855 Grandview Ave, Columbus, OH 43215

614-443-1178 www.dynamix-ltd.com

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

F

E

D

C

B

A

97 8654321

1 2 3 4 5 6 87 9

B

A

C

D

E

F

Department of Veterans Affairs

568-16-101

G-100

JBSREF23 FEB 2018

113 Comanche Road Fort Meade, SD 57741

FT MEADE SPS/ENDOSCOPY

RENOVATION

LIFE SAFETY PLAN - LEVEL 1 &

BASEMENT LEVEL

113, SURGERY TOWER

GENERAL BUILDING INFORMATION

OCCUPANCY AREA SCHEDULE LEVEL 1 (NFPA 101 7.3.1.2)

3/32" = 1'-0"F1 LIFE SAFETY PLAN - LEVEL 1

EXIT REQUIREMENTS

REQUIRED NUMBER OF EXITS PER CODE

NUMBER OF EXITS SHOWN ON PLANS:

REQUIRED DISTANCE BETWEEN EXIT DOORS PER CODE

ACTUAL DISTANCE BETWEEN EXIT DOORS:

SPRINKLED

68'-6" 99'-0"

OCCUPANCY LEGEND

LIFE SAFETY GRAPHIC KEY

Name Area Area Per Occupant Occpancy Clasification

Occupant Load

B, BUSINESS 14173 SF 100 SF Business areas 142 S-1, STORAGE 3541 SF 500 SF Accessory storage area, mechanical equipment room

Grand total 17714 SF 148

LIFE SAFETY GENERAL NOTES

3/32" = 1'-0"C1 LIFE SAFETY PLAN - BASEMENT LEVEL

Name Area Area Per Occupant Occpancy Clasification

Occupant Load

B, BUSINESS

(BASEMENT)

662 SF 100 SF Business areas 7

S-1, STORAGE

(BASEMENT)

102 SF 500 SF Accessory storage area, mechanical equipment room

Grand total 764 SF 8

OCCUPANCY AREA SCHEDULE BASEMENT LEVEL

(NFPA 101 7.3.1.2)

BUILDING CODE SUMMARY

NOTE: ALL WORK IS TO BE PREFORMED TO THE LATEST EDITION OF THE FOLLOWING

CODES, ORDINANCES, AND LAWS WHICH INCLUDE, BUT ARE NOT LIMITED TO:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD

STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL

INFORMATION LIBRARY (TIL)

• INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN

VA DESIGN DOCUMENTS)

• NFPA 101 LIFE SAFETY CODE

• NFPA NATIONAL FIRE CODES (WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900)

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• INTERNATIONAL PLUMBING CODE (IPC)

• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF

MECHANICAL ENGINEERS (ASME) A 17.1

• ASME BOILER AND PRESSURE VESSEL CODE

• ASME CODE FOR PRESSURE PIPING

• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABASS) INCLUDING

VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE(PG-18-13)

• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN

CONCRETE INSTITUTE AND COMMENTARY (ACI 318)

• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN

SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF

STEEL CONSTRUCTION (ASIC)

• ENERGY POLICY ACT OF 2005 (EPACT)

• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW

FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS

AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFT PARTS 433, 434 AND 435

• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS:

MEMORANDUM OF UNDERSTANDING (MOU)

• EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY,

AND TRANSPORTATION MANAGEMENT

• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS, STATED IN THE

GENERAL REQUIREMENTS SECTION 01010 OF THE VA MASTER CONSTRUCTION

SPECIFICATION

• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 62.1-

• SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15 - 2007

29'

41'

96'

A, ASSEMBLY (LEVEL 2)

B, BUSINESS (LEVEL 2)

I-2. INSTITUTIONAL (LEVEL 2)

NOT IN SCOPE (LEVEL 2)

S-1, STORAGE (LEVEL 2)

NOT IN SCOPE (LEVEL 2)

V

ATOTAL EXIT CAPACITY =

TOTAL OCCUPANT LOAD =

LEVEL 2 - ENDOSCOPY (2,704 SF)

68'

NOT IN SCOPE (LEVEL 2)

122'59'

ACTUAL DISTANCE = 79' - 8"

HE

STAIR

STS231

STAIR

STS241

1. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE

OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS

THAN 32 INCHES. THE HEIGHT OF DOORS SHALL NOT BE LESS THAN 80 INCHES.

2. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE

WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ALL

EGRESS DOORS TO HAVE PANIC HARDWARE. PANIC HARDWARE SHALL NOT

REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FORCE

REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.

3. THE MEANS OF EGRESS, AND EXIT DISCHARGE, SHALL BE ILLUMINATED AT ANY

TIME THE BUILDING IS OCCUPIED WITH A LIGHT INTENSITY OF NOT LESS THAN 1

FOOT-CANDLE AT THE WALKING SURFACE LEVEL.

4. THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT

ALL TIMES. NO STORAGE IS PERMITTED IN ANY EGRESS PATHS.

5. EXISTING FIRE EXTINGUISHERS ARE LOCATED THROUGHOUT THE EXISTING

BUILDING. LOCAL AUTHORITY TO REVIEW AND/OR APPROVE ALL EXISTING

LOCATIONS. ALL NEW PROPOSED F.E. LOCATIONS ARE DETERMINED BY NFPA 10

AND/OR BY THE DIRECTION OF THE LOCAL AUTHORITY.

6. PORTABLE FIRE EXTINGUISHER CABINETS TO BE SEMI-RECESSED, WITH A 2 1/2"

PROJECTION AND AN INSIDE BOX DIMENSION OF AT LEAST 24"H x 9 1/2"W x 6"D, CAPABLE OF ACCOMMODATING A 10LB, DRY CHEMICAL A/B/C TYPE FIRE

EXTINGUISHER.

BUILDING CODE DATA:

BUILDING CODE AGENCY/JURISDICTION:

BUILDING CODE:

BUILDING HEIGHT (ACTUAL; ALLOWABLE)

TOTAL # OF FLOORS; TOTAL ALLOWED:

TOTAL # OF FLOORS ABOVE GRADE:

BUILDING AREA (ACTUAL; ALLOWABLE):

PROJECT/BUILDING DATA:

NEW CONSTRUCTION TYPE:

EXIST. CONSTRUCTION TYPE:

REQUIRED FIRE RESISTANCE RATINGS:

STRUCTURAL FRAME:

BEARING WALLS (EXTERIOR; INTERIOR):

NONBEARING WALLS (EXTERIOR; INTERIOR):

FLOOR CONSTRUCTION:

ROOF CONSTRUCTION:

OCCUPANCY DATA:

MIXED USE/SEPARATED

OCCUPANCY GROUP(S)(NFPA 101 6.1.14.3):

EXIT CAPACITY FACTORS:

(NFPA 101 TABLE 7.3.3.1)

TRAVEL DISTANCE LIMITATIONS:

GROUP I (NFPA TABLE A7.6)

GROUP B (NFPA TABLE A7.6)

GROUP S, LOW HAZARD (NFPA TABLE A7.6)

ALL OTHER OCCUPANCIES:

FIRE PROTECTION SYSTEMS:

AUTOMATIC SPRINKLERS:

FIRE DEPARTMENT STANDPIPES:

FIRE ALARM SYSTEM:

SUPERVISION:

PORTABLE FIRE EXTINGUISHERS:

SMOKE AND HEAT DETECTION DEVICES:

OCCUPANT NOTIFICATION:

SMOKE MANAGEMENT SYSTEM:

NA

VA GUIDELINES AND STANDARDS

2015 NFPA 101 LIFE SAFETY CODE (NFPA 101)

2015 NFPA 220 STANDARD ON TYPES OF BUILDING

CONSTRUCTION (NFPA 220)

2002 NFPA 101B CODE FOR MEANS OF EGRESS FOR BUILDINGS

AND STRUCTURES (NFPA 101B)

2015 NFPA 5000 BUILDING CONSTRUCTION AND SAFETY YCODE

(NFPA 5000)

2013 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHER

31'-4"; 180'-0" (NFPA 5000 TABLE 7.4.1)

2-STORIES W/ BASEMENT; 12-STORIES (NFPA 5000 TABLE 7.4.1)

2-STORIES

26,891 SF; UNLIMITED (UL) (NFPA 5000 TABLE 7.4.1)

TYPE II-FR - (222), FIRE RESISTIVE, NON-COMBUSTIBLE

(NFPA 101 TABLE 18.1.6.1)

TYPE II-FR - (222)(NFPA 101 TABLE 19.1.6.1)

2-HOURS (NFPA 220 TABLE 4.1.1)

2-HOURS; 2 HOURS (NFPA 220 TABLE 4.1.1)

0-HOURS; 0 HOURS (NFPA 220 TABLE 4.1.1)

2-HOURS (NFPA 220 TABLE 4.1.1)

1-HOURS (NFPA 220 TABLE 4.1.1)

I-2. INSTITUTIONAL, PROCEDURE/RECOVERY ROOMS, BUILDING

113 LEVEL 2. (NFPA 101 6.1.5) B - BUSINESS, BUILDING 113

BASEMENT AND FIRST FLOOR NEW ADDITION (NFPA 101 6.1.11)

0.20 IN/OCC FOR HORIZONTAL EGRESS ELEMENTS

0.30 IN/OCC FOR VERTICAL EGRESS ELEMENTS

COMMON: TRAVEL: DEAD-END:

100 FEET 200 FEET 30 FEET

100 FEET 300 FEET 50 FEET

NO REQ. NO REQ. NO REQ.NA

FULLY SPRINKLERED (NFPA 101 18.3.5)(NFPA 13)

YES (NFPA 5000 55.4)(NFPA 14)

YES (NFPA 72)

YES (NFPA 5000 55.3.2)(NFPA 13)(NFPA 72)

YES; TRAVEL DISTANCE: 75 FT MAX. (NFPA 10 2013 TABLE

6.2.1.1)(NFPA 18.3.5.12)

YES (NFPA 5000 55.2.2.10)(NFPA 101 18.3.4.5)(NFPA 72)

YES (NFPA 5000 55.2.3)(NFPA 101 18.3.4.3.1)(NFPA 72)

NO

PROJECT SUMMARY:

STERILE PROCESSING SERVICE, SPECIAL PROCEDURES AND ENDOSCOPY AREAS RENOVATION.

THESE DRAWINGS INCLUDE THE INFORMATION AND SPECIFICATIONS FOR THE ARCHITECTURAL

SCOPE OF WORK. THE MECHANICAL, ELECTRICAL, PLUMBING, AND LIFE SAFETY DRAWINGS AND

SPECIFICATIONS SHALL BE SUBMITTED BY THE DESIGN-BUILD SUB CONTRACTORS.

PATH OF TRAVEL (FEET)

1-HOUR RATED

2-HOUR RATED

VOICE/ALARM SYSTEM THROUGHOUT

STANDPIPE HOSE OUTLET

EXIT FLOW

EXIT CAPACITY

SMOKE DETECTOR

(SEE ELECTRICAL)

V A

COMMON PATH OF TRAVEL (FEET)

START OF TRAVEL

EXIT SIGN

(SEE ELECTRICAL)

SMOKE PARTITION PORTABLE FIRE

EXTINGUISHER

2-HOUR BUILDING FIRE

SMOKE

HORIZONTAL EXITHE

S-1, STORAGE (PENTHOUSE)

STAIR

STS231

100% DOCUMENTS -

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

15 Sunnen Drive, Suite 104 | St.

Louis, Missouri 63143

314.645.1132 Fax: 314.645.1173

www.imegcorp.com

855 Grandview Ave, Columbus, OH 43215

614-443-1178 www.dynamix-ltd.com

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

F

E

D

C

B

A

97 8654321

1 2 3 4 5 6 87 9

B

A

C

D

E

F

Department of Veterans Affairs

568-16-101

G-101

JBSREF23 FEB 2018

113 Comanche Road Fort Meade, SD 57741

FT MEADE SPS/ENDOSCOPY

RENOVATION

LIFE SAFETY PLAN - LEVEL 2 AND

PENTHOUSE

113, SURGERY TOWER

GENERAL BUILDING INFORMATION

OCCUPANCY AREA SCHEDULE LEVEL 2 (NFPA 101 7.3.1.2)

EXIT REQUIREMENTS

REQUIRED NUMBER OF EXITS PER CODE (TABLE 1021.1)

NUMBER OF EXITS SHOWN ON PLANS:

REQUIRED DISTANCE BETWEEN EXIT DOORS PER CODE (SECTION

1015.2.1)

ACTUAL DISTANCE BETWEEN EXIT DOORS:

SPRINKLED

68'-6" 99'-0"

OCCUPANCY LEGEND

LIFE SAFETY GRAPHIC KEY

LIFE SAFETY GENERAL NOTES

OCCUPANCY AREA SCHEDULE MECHANICAL PENTHOUSE

(NPFA 101 7.3.1.2)

3/32" = 1'-0"F1 LIFE SAFETY PLAN - LEVEL 2

Name Area Area Per Occupant Occpancy Clasification

Occupant Load

A, ASSEMBLY (LEVEL 2) 698 SF 15 SF Assembly - Less concentrated use, without fixed seats

B, BUSINESS (LEVEL 2) 713 SF 100 SF Business areas 11 I-2. INSTITUTIONAL (LEVEL 2) 1259 SF 240 SF Institutional areas - Inpatient treatment areas

S-1, STORAGE (LEVEL 2) 347 SF 500 SF Accessory storage area, mechanical equipment room

Grand total 3016 SF 70

3/32" = 1'-0"C1 Penthouse

NOTE: ALL WORK IS TO BE PREFORMED TO THE LATEST EDITION OF THE FOLLOWING

CODES, ORDINANCES, AND LAWS WHICH INCLUDE, BUT ARE NOT LIMITED TO:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD

STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL

INFORMATION LIBRARY (TIL)

• INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN

VA DESIGN DOCUMENTS)

• NFPA 101 LIFE SAFETY CODE

• NFPA NATIONAL FIRE CODES

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• INTERNATIONAL PLUMBING CODE (IPC)

• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF

MECHANICAL ENGINEERS (ASME) A 17.1

• ASME BOILER AND PRESSURE VESSEL CODE

• ASME CODE FOR PRESSURE PIPING

• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABASS) INCLUDING

VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE(PG-18-13)

• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN

CONCRETE INSTITUTE AND COMMENTARY (ACI 318)

• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN

SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF

STEEL CONSTRUCTION (ASIC)

• ENERGY POLICY ACT OF 2005 (EPACT)

• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW

FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS

AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFT PARTS 433, 434 AND 435

• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS:

MEMORANDUM OF UNDERSTANDING (MOU)

• EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY,

AND TRANSPORTATION MANAGEMENT

• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS, STATED IN THE

GENERAL REQUIREMENTS SECTION 01010 OF THE VA MASTER CONSTRUCTION

SPECIFICATION

• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 62.1-

SAFETY STANDARD FOR REFRIGERATION SYSTEMS ASHRAE STANDARD 15 2007

BUILDING CODE SUMMARY

Name Area Area Per Occupant Occpancy Clasification

Occupant Load

S-1, STORAGE (PENTHOUSE) 2676 SF 500 SF Accessory storage area, mechanical equipment room

Grand total 2676 SF 5

UP

A

B

D

E

6 7 8

UP

004004

5'

- 7

8'

- 4

STAIR TOWER

STS005

CLEAN ELEVATOR

S003

ELEVATOR

EQUIPMENT

ECS002A

ANTEROOM

S006

CORRIDOR

CS001

H.A.C.

S004

181181

1. EXISTING CONDITIONS ARE BASED ON

INFORMATION OBTAINED FROM EXISTING

DRAWINGS AND FIELD SURVEY, AND SHALL NOT BE

CONSTRUED "AS BUILT." THE CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS PRIOR TO

ONSET OF CONSTRUCTION.

2. THE CONTRACTOR SHALL COORDINATE WITH

OWNER FOR ALL EXISTING EQUIPMENT AND

FURNITURE ITEMS THAT ARE TO BE SALVAGED OR

REINSTALLED PRIOR TO THE COMMENCEMENT OF

DEMOLITION.

3. ALL WALL PARTITIONS SHOWN DASHED ARE TO

BE REMOVED. THE CONTRACTOR SHALL PATCH

ALL PARTITIONS, CEILINGS, AND FLOORS

AFFECTED BY DEMOLITION TO MATCH ADJACENT

CONSTRUCTION.

4. ALL DOORS SHOWN DASHED ARE TO BE

REMOVED ALL ASSOCIATED DOOR FRAMES TO BE

REMOVED UNLESS NOTED.

5. THE OWNER SHALL HAVE THE FIRST RIGHT TO

ALL MATERIALS AND EQUIPMENT THAT ARE

REMOVED BY THE CONTRACTOR. THE

CONTRACTOR SHALL VERIFY WHEN REMOVAL OF

ITEMS ARE TO BE RETAINED BY THE OWNER AT THE

PRE CONSTRUCTION MEETING.

6. CLEAN AND PREPARE ALL SURFACES AFFECTED

BY DEMOLITION TO PRODUCE FLAT, EVEN SURFACE

TO RECEIVE NEW FINISHES.

7. CONTRACTOR SHALL PROTECT ALL EXISTING

BUILDING SURFACES TO REMAIN.

8. PATCH AND REPAIR SURFACES AND FINISHES

AFFECTED BY THE DEMOLITION OR THE REMOVAL

OF CONSTRUCTION AS NECESSARY TO MAINTAIN

THE FINISH QUALITY OF NEW SPACE.

9. FILL ALL DUCT AND PIPE PENETRATIONS IN DEMO

AREA WITH 2 - HOUR RATED ASSEMBLY.

10. COORDINATE SCHEDULING OF ANY

DEMOLITION/PLACEMENT OF RATED WALL

CONSTRUCTION WITH FIRE/LIFE SAFETY A.H.J.

11. CONTRACTOR PARKING AND PLACEMENT OF

STAGING AND WASTE MATERIALS TO BE

COORDINATED WITH FORT MEADE/VABHMC

PROJECT MANAGER PRIOR TO COMMENCEMENT OF

PROJECT WORK.

A

B

D

E

6 7 8

005002

STAIR TOWER

STS005

CONT. 1HR RATED PTN. TO UNDERSIDE OF

DECK ABOVE

AS CONTRACTOR OPTION, PROVIDE 1HR HORIZ.

ASSEMBLY TO NEAREST RATED CONST. IN LIEU

OF PTN. TO DECK

5/8" TYPE "X" GYP. BD. LEVEL 2 FINISH BOTH

SIDES ON 3-5/8" MTL. STUDS @ 2'-0" MAX. FLR

TO CLNG

EXIST. DECK ABOVE

FIRE CAULK EACH SIDE

FIRESAFE PENETRATIONS @ EXST. UTIL.

WITH 1HR RATED SYSTEM

NOTE: AS A CONTRACTOR OPTION, RECONFIGURE EXISTING SPRINKLER SYSTEMS TO

PROVIDE UPRIGHT HEADS FOR FULL SPRINKLER COVERAGE OF THE CONSTRUCTION AREA IN

LEIU OF RATED TEMPORARY SEPERATIONS UNTIL NEW CEILING FINISHES ARE INSTALLED.

100% DOCUMENTS -

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

15 Sunnen Drive, Suite 104 | St.

Louis, Missouri 63143

314.645.1132 Fax: 314.645.1173

www.imegcorp.com

855 Grandview Ave, Columbus, OH 43215

614-443-1178 www.dynamix-ltd.com

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

F

E

D

C

B

A

97 8654321

1 2 3 4 5 6 87 9

B

A

C

D

E

F

Department of Veterans Affairs

568-16-101

AD-100

MTREF23 FEB 2018

113 Comanche Road Fort Meade, SD 57741

FT MEADE SPS/ENDOSCOPY

RENOVATION

BASEMENT DEMOLITION PLAN

113, SURGERY TOWER

1/8" = 1'-0"C6 BASEMENT DEMOLITION

GENERAL NOTES:

KEYED NOTES:

001 EXISTING SUMP PITS TO REMAIN

002 PROVIDE OPENING IN FDN. WALL TO

ACCOMODATE PASS-THRU DOOR INTO EXISTING

SPS SPACE. REMOVE EXISTING WALL DOWN TO

TOP OF FOOTING.

003 RECONFIGURE EXIST. 4" DIA. DRAIN LEADER TO

ACCOMODATE HEADROOM CLEARANCE FOR

NEW DOOR OPENING; SEE PLUMBING DRAWINGS

004 SELECTIVELY DEMOLISH SLAB OR WALL AREA AS

NECESSARY FOR INSTALLATION OF NEW

ELEVATOR MACHINE ROOM EQUIPMENT AND

CONNECTIONS TO PIT-AREA.

005 REMOVE PORTION OF EXISTING PARTITION TO

ACCOMODATE NEW DOOR PASSAGE.

006 EXISTING 10" BUILDING DRAIN TO REMAIN.

007 EXISTING SPRINKLER RISER TO REMAIN.

008 EXISTING WALL MOUNTED FIRE SYSTEM PANELS

TO REMAIN.

059 PROVIDE TEMPORARY PARTITION WITH ACCESS

DOOR BETWEEN NEW WORK AREA AND EXISTING

HOSPITAL CORRIDOR PRIOR TO DEMOLITION

WORK AT OPENING.

063 REMOVE GYP. AND METAL STUDS AS REQUIRED

TO INSTALL ELEVATOR ENTRANCE AT EXISTING

CMU ROUGH OPENING

181 PREPARE WALL AND EXISTING SLAB TO EXTEND

REFRIGERANT PIPING BELOW SLAB AND ABOVE

BASEMENT CEILING. RE: MECHANICAL

1/8" = 1'-0"C4 PARTIAL DEMOLITION REFLECTED CEILING PLAN @ BASEMENT

1" = 1'-0"E6 FIRE RATED TEMPORARY DUST PARTITION

NOTE: NEW WALL OPENING AND DEMOLITION WORK IN EXISTING SPS SPACE TO

BE PHASED SUCH THAT THE EXISTING SPS DOES NOT REQUIRE SHUTDOWN OF

THE WORKING SPS. COORDINATE PHASING OF WORK IN THIS AREA WITH C.O.R.

TO MINIMIZE DISRUPTION OF CRITICAL HOSPITAL SERVICES.

B

C

D

E

F

G

H

J

5.1

5.1

DN

11 12 13 14 15

028028028028

EXISTING SHELL SPACE

EXISTING SHELL SPACE

MECHANICAL/ ELECTRICAL

032032

EXISTING

I.C.U.

EXISTING

PATIENT

SERVICES

OFFICES

AREA WELL

(EXTERIOR)

A-224 C1

Sim

065065

065065

011 011

STAIR

STS109

STAIR

STS108

STAIR

IA

1. EXISTING CONDITIONS ARE BASED ON

INFORMATION OBTAINED FROM EXISTING

DRAWINGS AND FIELD SURVEY, AND SHALL NOT BE

CONSTRUED "AS BUILT." THE CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS PRIOR TO

ONSET OF CONSTRUCTION.

2. THE CONTRACTOR SHALL COORDINATE WITH

OWNER FOR ALL EXISTING EQUIPMENT AND

FURNITURE ITEMS THAT ARE TO BE SALVAGED OR

REINSTALLED PRIOR TO THE COMMENCEMENT OF

DEMOLITION.

3. ALL WALL PARTITIONS SHOWN DASHED ARE TO

BE REMOVED. THE CONTRACTOR SHALL PATCH

ALL PARTITIONS, CEILINGS, AND FLOORS

AFFECTED BY DEMOLITION TO MATCH ADJACENT

CONSTRUCTION.

4. ALL DOORS SHOWN DASHED ARE TO BE

REMOVED ALL ASSOCIATED DOOR FRAMES TO BE

REMOVED UNLESS NOTED.

5. THE OWNER SHALL HAVE THE FIRST RIGHT TO

ALL MATERIALS AND EQUIPMENT THAT ARE

REMOVED BY THE CONTRACTOR. THE

CONTRACTOR SHALL VERIFY WHEN REMOVAL OF

ITEMS ARE TO BE RETAINED BY THE OWNER AT THE

PRE CONSTRUCTION MEETING.

6. CLEAN AND PREPARE ALL SURFACES AFFECTED

BY DEMOLITION TO PRODUCE FLAT, EVEN SURFACE

TO RECEIVE NEW FINISHES.

7. CONTRACTOR SHALL PROTECT ALL EXISTING

BUILDING SURFACES TO REMAIN.

8. PATCH AND REPAIR SURFACES AND FINISHES

AFFECTED BY THE DEMOLITION OR THE REMOVAL

OF CONSTRUCTION AS NECESSARY TO MAINTAIN

THE FINISH QUALITY OF NEW SPACE.

9. FILL ALL DUCT AND PIPE PENETRATIONS IN DEMO

AREA WITH 2 - HOUR RATED ASSEMBLY.

10. COORDINATE SCHEDULING OF ANY

DEMOLITION/PLACEMENT OF RATED WALL

CONSTRUCTION WITH FIRE/LIFE SAFETY A.H.J.

11. CONTRACTOR PARKING AND PLACEMENT OF

STAGING AND WASTE MATERIALS TO BE

COORDINATED WITH FORT MEADE/VABHMC

PROJECT MANAGER PRIOR TO COMMENCEMENT OF

PROJECT WORK.

100% DOCUMENTS -

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

15 Sunnen Drive, Suite 104 | St.

Louis, Missouri 63143

314.645.1132 Fax: 314.645.1173

www.imegcorp.com

855 Grandview Ave, Columbus, OH 43215

614-443-1178 www.dynamix-ltd.com

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

F

E

D

C

B

A

97 8654321

1 2 3 4 5 6 87 9

B

A

C

D

E

F

Department of Veterans Affairs

568-16-101

AD-101

MTREF23 FEB 2018

113 Comanche Road Fort Meade, SD 57741

FT MEADE SPS/ENDOSCOPY

RENOVATION

FIRST FLOOR DEMOLITION PLAN

113, SURGERY TOWER

1/8" = 1'-0"F1 LEVEL 1 DEMOLITION

GENERAL NOTES:

KEYED NOTES:

011 EXISTING CONCRETE PAD AND CHILLER TO

REMAIN

025 LEVEL AND PREP EXTERIOR SITE AREA AS

NECESSARY FOR NEW CONCRETE PAD

026 EXCAVATE SITE AREA AS NECESSARY FOR THE

INSTALLATION OF NEW DOCK FOOTINGS AND

STAIRS

027 REMOVE TEMPORARY INFILL FRAMING AND

EXTERIOR FINISH PANEL.

028 SELECTIVELY EXCAVATE EXISTING PLUMBING

STUB-UPS AS NECESSARY FOR INSTALLATION OF

NEW SUBGRADE DRAINS. LEVEL/PREP INTERIOR

GRADING AS NECESSARY FOR THE

INSTALLATION OF NEW SLAB AND SUBGRADE.

029 CUT OPENINGS FOR NEW ELEVATOR DOOR IN

EXISTING CMU SHAFT CONSTRUCTION 8"

LARGER THAN HOISTWAY ENTRANCE (3) SIDES.

VERIFY SUITABILITY OF EXISTING ELEVATOR PIT

FOR INSTALLATION OF NEW ELEVATORS AS

SPECIFIED.

031 DRILL OPENING FOR NEW HOSE BIB THRU

EXISTING EXTERIOR WALL.

032 CUT NEW OPENING THRU EXTERIOR WALL FOR

NEW DUCT/ LOUVERS. RE: MECH. FOR EXACT

SIZE AND LOCATION OF NEW OPENING. RE:

STRUCT. FOR REQUIREMENTS ON MAKING

OPENINGS.

037 REMOVE INFILL STOREFRONT SYSTEM TO

ACCOMODATE NEW OH DOCK DOOR OPENING.

039 REMOVE CMU SILL COURSE AS REQ'D FOR

INSTALLATION OF NEW CONC. STOOP. RE:

STRUCTURAL

059 PROVIDE TEMPORARY PARTITION WITH ACCESS

DOOR BETWEEN NEW WORK AREA AND EXISTING

HOSPITAL CORRIDOR PRIOR TO DEMOLITION

WORK AT OPENING.

060 REMOVE AND REPLACE EXISTING ACT OR GYP/

PLASTER CEILINGS AS REQ'D FOR MECHANICAL/

PLUMBING WORK

063 REMOVE GYP. AND METAL STUDS AS REQUIRED

TO INSTALL ELEVATOR ENTRANCE AT EXISTING

CMU ROUGH…

This is the start of the file's text. The full file is on GovTribe.