Bldg Reports count.pdf
PDF 86 KB Posted
- Attached to
- H342--Fire Alarm Inspection
- Solicitation number
- 36C26226Q0840
About this file
This document is a facilities management reference table detailing annual fire alarm (F.A.) and sprinkler system inspection and reporting requirements across 21 buildings at Los Angeles City College (LAACC).
The facility portfolio comprises 21 buildings with a combined total of 34 annual inspection reports required in 2021 and 2022. Of these buildings, 15 have dedicated Fire Alarm Panels requiring annual reports. The inspection requirements vary by building: most buildings require both F.A. and Sprinkler reports (16 buildings), while six buildings require Sprinkler reports only, one building requires F.A. reports only, and one building (the Chiller Plant) requires neither. Notable special conditions include Building 40 (Chiller Plant), which lacks both sprinklers and its own F.A. Panel; Building 63 (Vet Center), which has no sprinklers; and Building 202 (Boiler Plant), whose F.A. Panel monitors seven additional buildings (40, 44, 45, 46, 47, and 103). Additionally, the facility requires 19 quarterly Sprinkler Reports. In 2020, 15 annual F.A. reports were issued separately due to a concurrent five-year sprinkler inspection program.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 16111 Plummer St_Bldg 202_INS Q-FS_1-23-26_Redacted 1.pdf | ||
| 16111 Plummer St_Bldg 201_INS Q-FS_1-23-26_Redacted.pdf | ||
| 36C26226Q0840_6.docx | DOCX document | |
| 16111 Plummer St_Bldg 202_ANN FA_08.22.25_Redacted 1.pdf | ||
| S06 36C26226Q0840 0004.pdf | ||
| 16111 Plummer St_Bldg 103_ INS Q-FS_12-19-25_Redacted 1.pdf | ||
| LAACC Notifier FA Pointlist.pdf | ||
| 16111 Plummer St_Bldg 201_ANN FA_09.15.2025_Redacted.pdf | ||
| S06 36C26226Q0840 0003.pdf | ||
| 36C26226Q0840_4.docx | DOCX document | |
| Reports Alarm And Sprinklers.pdf | ||
| Q and A 36C26226Q0840.pdf | ||
| 36C26226Q0840_3.docx | DOCX document | |
| 36C26226Q0840 0001_1.docx | DOCX document | |
| S02 Solicitation 36C26226Q0840_Revised SOW A.2.pdf | ||
| S06 36C26226Q0840 Ammendment 0001.pdf | ||
| 36C26226Q0840_2.docx | DOCX document | |
| S02 Solicitation 36C26226Q0840_1.pdf | ||
| 36C26226Q0840.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bldg(s) that receive Annual F.A. or Sprinkler Reports
Bldg Count Reports expected LAACC (JACO Bldg) 2 F.A. & Sprinkler 1 2 F.A. & Sprinkler 7 2 F.A. & Sprinkler 10 (JACO Bldg) 2 F.A. & Sprinkler 20 2 F.A. & Sprinkler 22 2 F.A. & Sprinkler 23 2 F.A. & Sprinkler 24 2 F.A. & Sprinkler 25 2 F.A. & Sprinkler 40 Chiller Plant 0 NONE 44 1 Sprinkler only 45 1 Sprinkler only 46 1 Sprinkler only 47 1 Sprinkler only 62 2 F.A. & Sprinkler 63 Vet Center 1 F.A. only 99 (JACO Bldg) 2 F.A. & Sprinkler 103 1 Sprinkler only 200 (JACO Bldg) 2 F.A. & Sprinkler 201 IRM 2 F.A. & Sprinkler 202 Boiler Plant 2 F.A. & Sprinkler Total 21 Bldgs 34
*Notes:
Bldg(s) 40 & 63 do not have Sprinklers Bldg 40 does not have its own F.A. Panel Bldg 202 [Boiler Plant] F.A. Panel monitors Bldg(s) 40, 44, 45, 46, 47 & 103. {7 Bldgs Total} Total of 15 Bldgs with Fire Alarm Panels to get Annual Reports
Total Combined Annual reports in 2021 & 2022 (FA & Sp): 34 Total Quarterly Sprinkler Reports: 19 Total Annual FA Reports in 2020: 15 [We separated them in 2020 due to the 5 Year Sprinkler Inspection Performed]