16111 Plummer St_Bldg 202_INS Q-FS_1-23-26_Redacted 1.pdf
PDF 2 MB Posted
- Attached to
- H342--Fire Alarm Inspection
- Solicitation number
- 36C26226Q0840
About this file
This is an Inspection, Testing, and Maintenance Cover Sheet and Quarterly/Annual Report for fire protection systems, prepared in accordance with NFPA 25 (2011 edition) as amended by California Code of Regulations, Title 19.
The document covers SACC Building 202 located at 16111 Plummer Street, North Hills, California 91343, a 2-story Type I-A construction building built in 1993 used for occupancy type I2. The property contact is Keith Hayhurst at (310) 714-5379. The inspection report is dated 1/23/26 with an annual inspection certification dated 12/19/25. Only the Automatic Sprinkler System was inspected; no forms were submitted for Standpipe and Hose System, Private Water Supply System, Fire Pump, Water Storage Tank, Water Spray System, Foam Water Sprinkler System, or Water Mist System. The building has one identified riser located in the north center warehouse with a 6-inch riser diameter and 2-inch main drain diameter. The main drain static pressure test recorded 110 psi initial static pressure. The quarterly and annual inspection items cover control valves, waterflow alarm devices, supervisory devices, gauges, pressure readings, heat tape, spare sprinklers, fire department connections, alarm valves, pressure reducing valves, backflow preventers, and hose connections. Deficiencies noted on 12/19/25 included items 1.1, 1.13, and 1.19 (Sprinklers). The contractor or licensed owner certification confirms full inspection, testing, and maintenance completion in accordance with CCR Title 19, Sections 901-906, with equipment fully operable except as noted in the deficiencies section.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 16111 Plummer St_Bldg 201_INS Q-FS_1-23-26_Redacted.pdf | ||
| 36C26226Q0840_6.docx | DOCX document | |
| LAACC Notifier FA Pointlist.pdf | ||
| 16111 Plummer St_Bldg 103_ INS Q-FS_12-19-25_Redacted 1.pdf | ||
| Bldg Reports count.pdf | ||
| 16111 Plummer St_Bldg 201_ANN FA_09.15.2025_Redacted.pdf | ||
| 16111 Plummer St_Bldg 202_ANN FA_08.22.25_Redacted 1.pdf | ||
| S06 36C26226Q0840 0004.pdf | ||
| Reports Alarm And Sprinklers.pdf | ||
| S06 36C26226Q0840 0003.pdf | ||
| 36C26226Q0840_4.docx | DOCX document | |
| 36C26226Q0840_3.docx | DOCX document | |
| Q and A 36C26226Q0840.pdf | ||
| 36C26226Q0840 0001_1.docx | DOCX document | |
| 36C26226Q0840_2.docx | DOCX document | |
| S06 36C26226Q0840 Ammendment 0001.pdf | ||
| S02 Solicitation 36C26226Q0840_Revised SOW A.2.pdf | ||
| S02 Solicitation 36C26226Q0840_1.pdf | ||
| 36C26226Q0840.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .