16111 Plummer St_Bldg 202_ANN FA_08.22.25_Redacted 1.pdf
PDF 4 MB Posted
- Attached to
- H342--Fire Alarm Inspection
- Solicitation number
- 36C26226Q0840
About this file
This is a Fire Alarm System Inspection and Test Report for Building 202 located at 16111 Plummer Street, North Hills, California, dated August 22, 2025. The inspection was conducted for VA SACC by contact Keith Hayhurst, with an annual inspection frequency. The facility has one floor and an addressable fire alarm system with two primary control panels: an EST iOS Main Panel (12V, 44 AH batteries installed in 2022) and a Teleguard Tg-7 Dialer (12V, 7 AH batteries installed in 2024).
The inspection report documents comprehensive system testing across multiple operational areas, including control panel functionality, annunciator panel operation, system printer performance, voice evacuation notification systems, fireman phone systems, and fire pump auxiliary functions. Auxiliary functions tested include door holders and elevator recall. The report details inspection of 11 duct detectors across multiple buildings and locations, 4 power supply units at the mezzanine level (SK5495 model panels, 12V, 7 AH batteries, installed 2025), and 9 notification appliances including horns and strobes across multiple buildings. An Initiation Field Device Test section documents testing of 30 devices including heat detectors, manual pull stations, smoke detectors, water flow devices, and tamper switches across various buildings. All tested systems and devices passed inspection with no deficiencies noted. The liability release statement indicates the Owner retains full responsibility for the fire protection system's operating condition and any required corrections to identified deficiencies.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 16111 Plummer St_Bldg 201_INS Q-FS_1-23-26_Redacted.pdf | ||
| 36C26226Q0840_6.docx | DOCX document | |
| LAACC Notifier FA Pointlist.pdf | ||
| 16111 Plummer St_Bldg 103_ INS Q-FS_12-19-25_Redacted 1.pdf | ||
| Bldg Reports count.pdf | ||
| 16111 Plummer St_Bldg 201_ANN FA_09.15.2025_Redacted.pdf | ||
| 16111 Plummer St_Bldg 202_INS Q-FS_1-23-26_Redacted 1.pdf | ||
| S06 36C26226Q0840 0004.pdf | ||
| Reports Alarm And Sprinklers.pdf | ||
| S06 36C26226Q0840 0003.pdf | ||
| 36C26226Q0840_4.docx | DOCX document | |
| 36C26226Q0840_3.docx | DOCX document | |
| Q and A 36C26226Q0840.pdf | ||
| 36C26226Q0840 0001_1.docx | DOCX document | |
| 36C26226Q0840_2.docx | DOCX document | |
| S06 36C26226Q0840 Ammendment 0001.pdf | ||
| S02 Solicitation 36C26226Q0840_Revised SOW A.2.pdf | ||
| S02 Solicitation 36C26226Q0840_1.pdf | ||
| 36C26226Q0840.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .