Attachment 8 - As Build Drawings_0002.pdf
PDF 5 MB Posted
- Attached to
- AMENDED Egg Conference Room Audio/Visual Upgrade
- Solicitation number
- 36C26226Q0189
About this file
This document is a detailed audiovisual (AV) system design and equipment specification for the VA Long Beach facility, specifically focusing on the EGG Conference Room in Building 165. The design encompasses a comprehensive AV infrastructure including multiple conference rooms (D103, D104, D105) with integrated technology such as Samsung 86" 4K LED displays, Christie projectors, Crestron touch panels, Wyrestorm decoders, Extron media ports, and Biamp Tesira audio servers. The system includes sophisticated audio distribution with Innovox soundbars, Crown amplifiers, and Renkus Heinz speakers, networked across multiple zones with Netgear POE switches and middleware for control and connectivity.
The technical design includes detailed signal routing, connection diagrams, cable specifications, and equipment rack layouts for three primary conference room podiums. Key technological components include USB extenders, multiview switchers, control processors, and extensive networking equipment to enable seamless audio-visual presentation and collaboration capabilities. The design incorporates redundant networking, power distribution units with environmental monitoring, and flexible input/output configurations to support various presentation and meeting scenarios across different conference room spaces.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Regan Technologies Corp VA Long Beach 5901 E. 7th Street Long Beach, CA 90822
Building 165, EGG Conference Room
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
ORIGINAL ISSUE DATE
AutoCAD SHX Text
REVISION LEVELL
AutoCAD SHX Text
LATEST REVISION ISSUE DATE
AutoCAD SHX Text
AV-100
AutoCAD SHX Text
TITLE PAGE - DRAWING INDEX
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AV-200
AutoCAD SHX Text
BUILDING PLAN LEGEND
AutoCAD SHX Text
AV-201
AutoCAD SHX Text
1ST FLOOR - EGG CONFERENCE ROOM FACILITY PLAN
AutoCAD SHX Text
AV-202
AutoCAD SHX Text
EGG CONFERENCE ROOM DEVICE PLAN & RCP
AutoCAD SHX Text
AV-300
AutoCAD SHX Text
ONE LINE DRAWING LEGEND
AutoCAD SHX Text
AV-301
AutoCAD SHX Text
EGG CONFERENCE ROOM VIDEO ONE LINE
AutoCAD SHX Text
AV-302
AutoCAD SHX Text
EGG CONFERENCE ROOM AUDIO ONE LINE
AutoCAD SHX Text
AV-303
AutoCAD SHX Text
EGG CONFERENCE ROOM CONTROL ONE LINE
AutoCAD SHX Text
AV-304
AutoCAD SHX Text
PODIUM AUDIO/VIDEO/CONTROL ONE LINE
AutoCAD SHX Text
AV-601
AutoCAD SHX Text
AV EQUIPMENT RACK ELEVATION
AutoCAD SHX Text
AV-900
AutoCAD SHX Text
TYP AV SYSTEM STANDARD PINOUT DETAILS
AutoCAD SHX Text
AV-901
AutoCAD SHX Text
TYP AV SYSTEM STANDARD PINOUT DETAILS
AutoCAD SHX Text
AV-902
AutoCAD SHX Text
PROJECT PIN OUT DETAILS
AutoCAD SHX Text
AV-903
AutoCAD SHX Text
PROJECT PIN OUT DETAILS
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
ORIGINAL ISSUE DATE
AutoCAD SHX Text
REVISION LEVELL
AutoCAD SHX Text
LATEST REVISION ISSUE DATE
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EACH DEVICE IN AN AV SYSTEM ARE GIVEN AN IDENTIFYING DEVICE TYPE ABBREVIATION AND NUMBER COUNTING THE QUANTITY OF THAT DEVICE WITHIN THAT SYSTEM. SEE AV-300 FOR THE DEVICE ABBREVIATION LEGEND. DEVICE ID'S ARE USED THROUGHOUT THE AV DRAWING SET.
AutoCAD SHX Text
DEVICE ID LEGEND
AutoCAD SHX Text
DDD-XXX
AutoCAD SHX Text
DEVICE QUANITY
AutoCAD SHX Text
DEVICE TYPE ABBREVIATION
AutoCAD SHX Text DEVICE ID'S AND CABLES IN AN AV SYSTEM ARE GIVEN A UNIQUE NUMBER PER SYSTEM. SELF-CONTAINED SYSTEMS THAT DO NOT TIE TO A MASTER ARE ONLY UNIQUE WITHIN THAT SUB-SYSTEM. BECAUSE OF THIS VARIOUS ROOMS (SYSTEMS) ON FLOOR PLANS AND RCP'S MAY HAVE SIMILAR DEVICE ID'S. THIS HELPS TRACKING AND UNDERSTANDING MULTIPLE SUB-SYSTEMS TO HAVE SIMILAR DEVICES AND ID'S HANDLED THE SAME IN EACH ROOM (SYSTEM).
AutoCAD SHX Text
NUMBERING SEQUENCE
AutoCAD SHX Text
DRAWING SERIES LEGEND
AutoCAD SHX Text
AV-000 TO AV-099
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
AV-100 TO AV-199
AutoCAD SHX Text
TITLE AND DRAWING INDEX
AutoCAD SHX Text
AV-200 TO AV-299
AutoCAD SHX Text
BUILDING PLANS, LAYOUTS, RISERS
AutoCAD SHX Text
AV-300 TO AV-399
AutoCAD SHX Text
SYSTEM ONE LINE DRAWINGS - NON COMPLEX A/V/C COMBINED
AutoCAD SHX Text
AV-300 TO AV-399
AutoCAD SHX Text
AUDIO ONE LINE DRAWINGS - COMPLEX
AutoCAD SHX Text
AV-400 TO AV-499
AutoCAD SHX Text
VIDEO ONE LINE DRAWINGS - COMPLEX
AutoCAD SHX Text
AV-500 TO AV-599
AutoCAD SHX Text
CONTROL ONE LINE DRAWINGS - COMPLEX
AutoCAD SHX Text
AV-600 TO AV-699
AutoCAD SHX Text
EQUIPMENT RACK, CABINET, CREDENZA ELEVATIONS
AutoCAD SHX Text
AV-700 TO AV-799
AutoCAD SHX Text
I/O PLATES, PANEL LAYOUTS, PATCHBAY LAYOUTS
AutoCAD SHX Text
AV-800 TO AV-899
AutoCAD SHX Text
MECHANICAL DETAILS, WALL/CEILING/FLOOR MOUNTING DETAILS
AutoCAD SHX Text
AV-900 TO AV-999
AutoCAD SHX Text
WIRING DIAGRAMS, PINOUT DETAILS, CUSTOM CABLING DETAILS
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
TITLE PAGE - DRAWING INDEX
AutoCAD SHX Text
AV 45492-100
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REGAN TECHNOLOGIES CORP
AutoCAD SHX Text
VA LONG BEACH, CA
AutoCAD SHX Text 45492
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
AutoCAD SHX Text FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
M O N I T O R
S I D E
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPEAKER TYPES
AutoCAD SHX Text
SCREEN/LIFT TYPES
AutoCAD SHX Text
WALL TOUCH PNL TYPES
AutoCAD SHX Text
AV DEVICE OR BOX - WALL, CEILING, FLOOR
AutoCAD SHX Text
CABLE QTY/WIRE TYPE
AutoCAD SHX Text
CABLE ROUTING INFO
AutoCAD SHX Text
CONDUIT SIZE/NOTE
AutoCAD SHX Text Q
AutoCAD SHX Text T
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
XX
AutoCAD SHX Text
AV BUILDING INFRASTRUCTURE SYMBOL LEGEND
AutoCAD SHX Text
WALL
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text JUNCTION BOX WITH COVER PLATE FOR AV CONNECTION. PROVIDED BY E.C. MOUNT FLUSH WITH FINISHED WALL/CEILING TREATMENT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT UNLESS OTHERWISE INDICATED. FLOOR JB ARE SUBJECT TO POKE-THRU AND FLOOR BOX INSERTS ETC. SUB-NUMBER INDICATES NUMBER OF GANG. SEE GANG BOX TYPE LIST.
AutoCAD SHX Text JUNCTION BOX FOR A/V CONNECTIVITY. SEE JUNCTION BOX TYPES LIST AND WALL BOX MOUNTING METHODS.
AutoCAD SHX Text JUNCTION BOX FOR WALL/CEILING CAMERA LOCATIONS. MOUNT FLUSH WITH FINISHED WALL/CEILING TREATMENT. SUB-NUMBER INDICATES NUMBER OF GANG.
AutoCAD SHX Text
SPECIAL OUTLET
AutoCAD SHX Text
DATA (BUILDING LAN) SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
TV CABLE. SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
POTS TELCO ANALOG PHONE LINE
AutoCAD SHX Text
POKE THRU LOCATION
AutoCAD SHX Text
DUPLEX OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
QUAD CEILING OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
SINGLE WALL OUTLET, 3 PIN EDISON
AutoCAD SHX Text SINGLE TWIST LOCK OUTLET w/RATING
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
DEDICATED CIRCUIT
AutoCAD SHX Text
DEDICATED CIRCUIT WITH ISOLATED GROUND
AutoCAD SHX Text W
AutoCAD SHX Text
FB
AutoCAD SHX Text C
AutoCAD SHX Text
JB
AutoCAD SHX Text
CAM
AutoCAD SHX Text
CAM
AutoCAD SHX Text 20A
AutoCAD SHX Text 20A
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
IG
AutoCAD SHX Text D
AutoCAD SHX Text
D/IG
AutoCAD SHX Text
IG
AutoCAD SHX Text D
AutoCAD SHX Text
D/IG
AutoCAD SHX Text
IG
AutoCAD SHX Text D
AutoCAD SHX Text
D/IG
AutoCAD SHX Text
1. BOX MOUNTING HEIGHTS ARE TO CENTER OF FACE OF BOX. BOX MOUNTING HEIGHTS ARE TO CENTER OF FACE OF BOX. 2. BOX MOUNTING DEPTHS ARE TO FACE OF BOX. BOX MOUNTING DEPTHS ARE TO FACE OF BOX. 3. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED U.O.N. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED U.O.N. BOXES AND CONDUIT ON EXISTING WALLS AND CEILINGS MAY BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 4. VERIFY ALL STANDARD HEIGHTS WITH PREVAILING CONDITIONS AT JOBSITE. VERIFY ALL STANDARD HEIGHTS WITH PREVAILING CONDITIONS AT JOBSITE. 5. THESE DRAWINGS ARE FOR REQUIREMENTS REFERENCE ONLY. NOT FOR CONSTRUCTION. COORDINATE WITH THESE DRAWINGS ARE FOR REQUIREMENTS REFERENCE ONLY. NOT FOR CONSTRUCTION. COORDINATE WITH ARCHITECT FOR ALL DEVICE LOCATIONS. 6. SUPPLY AND INSTALLATION OF ALL CONDUIT, POWER CIRCUITS, BACK BOXES, ELECTRICAL DEVICES, SUPPLY AND INSTALLATION OF ALL CONDUIT, POWER CIRCUITS, BACK BOXES, ELECTRICAL DEVICES, ELECTRICAL WIRING IS TO BE PROVIDED BY THE PROJECT DIVISION 16 CONTRACTOR UNLESS NOTED OTHERWISE. 7. ALL CONDUIT SHALL BE STEEL (EMT OR RIGID). ALUMINUM, FIBERGLASS, OR PVC NOT ACCEPTABLE. FLEX ALL CONDUIT SHALL BE STEEL (EMT OR RIGID). ALUMINUM, FIBERGLASS, OR PVC NOT ACCEPTABLE. FLEX CONDUIT SHALL NOT BE CONSIDERED ACCEPTABLE. 8. E.C. SHALL INSTALL NYLON ROPE IN ALL CONDUITS FOR WIRING SPECIFIED IN DIVISION 11. AND CONDUIT E.C. SHALL INSTALL NYLON ROPE IN ALL CONDUITS FOR WIRING SPECIFIED IN DIVISION 11. AND CONDUIT SHALL BE DE-BURRED, CLEANED, CAPPED. CONDUIT STUB-OUTS, JUNCTION BOXES, AND OUTLETS SHALL BE SUITABLY LABELED FOR IDENTIFICATION OF FUNCTION, J-BOX #, AND/OR CONDUIT NUMBER. 9. E.C. TO PROVIDE BLANK COVER PLATES FOR ALL JUNCTION BOXES IF REQUIRED FOR BUILDING E.C. TO PROVIDE BLANK COVER PLATES FOR ALL JUNCTION BOXES IF REQUIRED FOR BUILDING INSPECTIONS. 10. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 180º TOTAL OF BENDS. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 180º TOTAL OF BENDS. 11. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 100 RUNNING FEET OF CONDUIT. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 100 RUNNING FEET OF CONDUIT. 12. INTERMEDIATE PULL BOXES SHALL BE 12"x12"x4", MINIMUM IF ANY CONDUIT ENTRY IS 1-1/4" OR INTERMEDIATE PULL BOXES SHALL BE 12"x12"x4", MINIMUM IF ANY CONDUIT ENTRY IS 1-1/4" OR LARGER. 13. INTERMEDIATE PULL BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP IF ALL CONDUIT ENTRIES ARE 1" INTERMEDIATE PULL BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP IF ALL CONDUIT ENTRIES ARE 1" OR LESS. 14. ALL 120 VOLT WIRE, DEVICES, AND CONNECTIONS BY E.C. ALL 120 VOLT WIRE, DEVICES, AND CONNECTIONS BY E.C. 15. ALL LOW VOLTAGE A/V SYSTEM DEVICES, AND CONNECTIONS BY A/V SYSTEM CONTRACTOR. ALL LOW VOLTAGE A/V SYSTEM DEVICES, AND CONNECTIONS BY A/V SYSTEM CONTRACTOR. 16. ALL GANG-BOXES SHALL BE 3 1/2" DEEP, MINIMUM, SINGLE PIECE CONSTRUCTION. MODULAR BOXES ARE ALL GANG-BOXES SHALL BE 3 1/2" DEEP, MINIMUM, SINGLE PIECE CONSTRUCTION. MODULAR BOXES ARE NOT ACCEPTABLE. ACCEPTABLE. 17. FLUSH OR RECESS MOUNTED 1 & 2-GANG BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP BOX FLUSH OR RECESS MOUNTED 1 & 2-GANG BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP BOX WITH APPROPRIATE PLASTER RING EXTENSION U.O.N. 18. EC TO PROVIDE ALL CONDUIT, J-BOXES, NEMA OR CUSTOM ENCLOSURES, FLOOR BOXES, POWER CIRCUITS, EC TO PROVIDE ALL CONDUIT, J-BOXES, NEMA OR CUSTOM ENCLOSURES, FLOOR BOXES, POWER CIRCUITS, POWER WIRE AND POWER CONNECTIONS UNDER THIS SECTION. DEVICE PLATES AND CONNECTOR PANEL INFORMATION IS FOUND IN THE AV-700 SET OF DRAWINGS. 19. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED. BOXES ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED. BOXES AND CONDUIT ON EXISTING WALLS AND CEILINGS MAY BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 20. SUPPORT ALL LOUDSPEAKER ENCLOSURES FROM STRUCTURE RATHER THAN FROM CEILING. SUPPORT ALL LOUDSPEAKER ENCLOSURES FROM STRUCTURE RATHER THAN FROM CEILING. 21. ALL WIRING SHALL BE IN CONDUIT IN INACCESSIBLE AREAS UNLESS OTHERWISE NOTED. ALL DEVICES ALL WIRING SHALL BE IN CONDUIT IN INACCESSIBLE AREAS UNLESS OTHERWISE NOTED. ALL DEVICES CONNECTED WITH MINIMUM 3/4"C. 22. REFER TO ARCHITECTURAL ELEVATIONS AND CEILING PLANS FOR EXACT PLACEMENT OF FINISHES WITH REFER TO ARCHITECTURAL ELEVATIONS AND CEILING PLANS FOR EXACT PLACEMENT OF FINISHES WITH DESIGN ARCHITECT. 23. FLOOR PLANS ARE FINAL AUTHORITY OF DEVICE QUANTITIES WHICH ARE SUBJECT TO REVISION PROVIDING FLOOR PLANS ARE FINAL AUTHORITY OF DEVICE QUANTITIES WHICH ARE SUBJECT TO REVISION PROVIDING PROPER NOTICE. 24. WHERE NO BACKBOX IS REQUIRED PLEASE REFERENCE THE MANUFACTURER'S INSTALLATION DETAIL FOR WHERE NO BACKBOX IS REQUIRED PLEASE REFERENCE THE MANUFACTURER'S INSTALLATION DETAIL FOR ROUGH-IN AND CONDUIT TERMINATION. 25. WHERE EXACT DIMENSIONS ARE NOT CALLED OUT, THE LOCATION OF EQUIPMENT, JUNCTION BOXES, WHERE EXACT DIMENSIONS ARE NOT CALLED OUT, THE LOCATION OF EQUIPMENT, JUNCTION BOXES, OUTLETS, WIRE WAYS, PANELS, ETC., ARE TO BE IDENTIFIED ON COORDINATION DRAWINGS FOR REVIEW ACCORDING TO PROJECT GENERAL CONDITIONS. 26. PROVIDE TEMPORARY LABELING DESCRIBING BOXES. PROVIDE TEMPORARY LABELING DESCRIBING BOXES. 27. CONCEAL CONDUIT CONNECTIONS TO JUNCTION BOXES MOUNTED IN PUBLIC AREAS. WHERE BOXES ARE CONCEAL CONDUIT CONNECTIONS TO JUNCTION BOXES MOUNTED IN PUBLIC AREAS. WHERE BOXES ARE SURFACE MOUNTED, CONDUIT SHALL ENTER FROM THE REAR OF THE BOX. 28. REFER TO FLOOR PLANS AND CONDUIT RISER DIAGRAMS FOR CONDUIT SIZING AND INTERCONNECTION OF REFER TO FLOOR PLANS AND CONDUIT RISER DIAGRAMS FOR CONDUIT SIZING AND INTERCONNECTION OF VARIOUS DEVICES. 29. CONSTANT VOLTAGE LOUDSPEAKER CABLE SHALL BE ROUTED IN CONDUIT WHEN EXPOSED, INACCESSIBLE CONSTANT VOLTAGE LOUDSPEAKER CABLE SHALL BE ROUTED IN CONDUIT WHEN EXPOSED, INACCESSIBLE OR AS REQUIRED BY SITE CONDITIONS. 30. CONDUIT RUN IN SLABS SHALL HAVE A PULL BOX LOCATED FOR EACH 180 DEGREE BEND. CONDUIT RUN IN SLABS SHALL HAVE A PULL BOX LOCATED FOR EACH 180 DEGREE BEND. 31. FOR EVERY 100 FEET OF STRAIGHT EMPTY CONDUIT, THERE SHALL BE A MINIMUM OF ONE PULL BOX, AND FOR EVERY 100 FEET OF STRAIGHT EMPTY CONDUIT, THERE SHALL BE A MINIMUM OF ONE PULL BOX, AND AN ACCESSIBLE PULL BOX FOR MORE THAN TWO 90 DEGREE BENDS IN A CONDUIT RUN. 32. THE DRAWINGS INDICATE ONE ROUTING METHOD FOR THE CONDUITS. MINOR CHANGES MAY BE MADE TO THE DRAWINGS INDICATE ONE ROUTING METHOD FOR THE CONDUITS. MINOR CHANGES MAY BE MADE TO CONDUIT SYSTEM TO ACCOMMODATE SITE CONDITIONS OR SIMPLIFY INSTALLATION AS LONG AS ADEQUATE SIZING IS MAINTAINED AND THE SYSTEM INSTALLER AND ARCHITECT APPROVE THE COORDINATION DRAWINGS SUBMITTED FOR REVIEW. 33. E.C. TO PROVIDE CABLE PROTECTION BUSHINGS ON ALL BOXES AND CONDUIT STUB-OUTS. E.C. TO PROVIDE CABLE PROTECTION BUSHINGS ON ALL BOXES AND CONDUIT STUB-OUTS. 35. POWER JUNCTION BOX. SURFACE MOUNT AT 96" A.F.F. PROVIDE 20A CIRCUITS WITH DEDICATED NEUTRALS AND OVERSIZED GROUND BACK TO PANEL "AV". LEAVE CIRCUIT TAIL AT 20' LENGTH FOR TERMINATION TO "AV", "TV", "ER" TYPE RACKS 36. MOUNT DISPLAYS AT 60" O.C. A.F.F. UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATIONS AND MOUNTING WITH MOUNT DISPLAYS AT 60" O.C. A.F.F. UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATIONS AND MOUNTING WITH ARCHITECT. 37. PROJECTION SCREEN BACKBOX PROVIDED BY A/V AND INSTALLED BY GC. PROVIDE GANG BOX CONNECTIONS FOR LOW-VOLTAGE CONTROL AND MOTOR POWER FROM NEAREST POWER PANEL. SCREENS TO BE CONTROLLED BY A/V. 38. L/V CONTRACTOR TO PULL, TERMINATE, AND TEST ALL RISER AND DISTRIBUTION CABLING INCLUDING FIBER, AND NETWORK CATEGORY CABLES.
AutoCAD SHX Text -------CONTRACTORS------- A/V = PROJECT DIVISION 11 (SUB)CONTRACTOR. E.C. = PROJECT DIVISION 16 (SUB)CONTRACTOR. LVC = PROJECT LOW VOLTAGE (SUB) CONTRACTOR. -------MOUNTING LOCATION/ORIENTATION------- AFC = ABOVE FINISHED CEILING AFF = ABOVE FINISHED FLOOR B.C.P. = BLANK COVER PLATE BCS = BELOW COUNTER-TOP SURFACE BFC = BELOW FINISHED CEILING BFF = BELOW FINISHED FLOOR BOB = BOTTOM OF BOX COB = CENTER OF BOX SRH = PROJECT STANDARD RECEPTACLE HEIGHT SSH = PROJECT STANDARD SWITCH HEIGHT HT. = HEIGHT RU = RACK UNIT ( 1.75" HIGH x 19.25" WIDE ) -------STAGE/HOUSE DIRECTIONS------- BOH = BACK OF HOUSE BOH-L = BACK OF HOUSE LEFT BOH-R = BACK OF HOUSE RIGHT CS = CENTER STAGE (MID STAGE) DSC = DOWN STAGE CENTER DSL = DOWN STAGE LEFT DSR = DOWN STAGE RIGHT FOH = FRONT OF HOUSE FOH-L = FRONT OF HOUSE LEFT FOH-R = FRONT OF HOUSE RIGHT HC = HOUSE CENTER HL - HOUSE LEFT HR = HOUSE RIGHT SL = STAGE LEFT SR = STAGE RIGHT USC = UP STAGE CENTER USL = UP STAGE LEFT USR = UP STAGE RIGHT -------SIGNAL GROUPS------- A = AUDIO LEVEL SIGNAL V = VIDEO TYPE LEVEL SIGANAL C = CONTROL LEVEL SIGNAL H = HI RESOLUTION VIDEO SIGNAL F.O. = FIBER OPTIC RF = RADIO FREQUENCY SIGNAL -------TELECOMMUNICATIONS------- IDF = INTERMEDIATE DISTRIBUTION FACILITY IP = INTERNET PROTOCOL LAN = LARGE AREA NETWORK MDF = MAIN DISTRIBUTION FACILITY MDP= MATV DISTRIBUTION PROCESSOR VLAN = VIRTUAL LAN WAN = WIDE AREA NETWORK WAP = WIRELESS ACCESS POINT -------ELECTRICAL/POWER/RELAYS/SWITCHING------- e.c. EMPTY CONDUIT I.G. = ISOLATED GROUND (TECHNICAL GROUND) I.P. = ISOLATED POWER (BALANCED POWER) n.o. = NORMALLY OPEN CONTACT n.c. = NORMALLY CLOSED CONTACT -------DEVICE/INPUT/OUTPUT------- C.P. = COVER PLATE CH = CHANNEL COMB = COMBINER CSP = CONTROL SYSTEM PROCESSOR DSP - DIGITAL SIGNAL PROCESSOR DVP = DIGITAL VIDEO PLAYER ER = EQUIPMENT RACK ex. = EXISTING EQUIPMENT MOD = MODULATOR RX = RECEIVE SERV = SERVER TP = TOUCH PANEL TX - TRANSMIT VDP = VIDEO DISTRIBUTION PROCESSOR -------PROVISIONS--------- O.F.E. = OWNER FURNISHED EQUIPMENT O.F.O.I. = OWNER FURNISHED, OWNER INSTALLED O.F.C.I. = OWNER FURNISHED, CONTRACTOR INSTALLED C.F.O.I. = CONTRACTOR FURNISHED, OWNER INTALLED C.F.C.I. = CONTRACTOR FURNISHED, CONTRACTOR INSTALLED C.F.E.I = CONTRACTOR FURNISHED, ELECTRICAL INSTALLED E.F.E.I = ELECTRICAL FURNISHED, ELECTRICAL INSTALLED -------MISC------- AR = AS REQUIRED BY DOCUMENTS AS = AS SHOWN ON DRAWINGS CL = CENTER LINE IP = IPOD MB = MOUNTING BRACKET N.I.C. = NOT IN CONTRACT (FUTURE OR BY OTHERS) N/A = NOT APPLICABLE n/c = NO CONNECTION N/R = NOT REQUIRED N/U = NOT USED POE = POWER OVER ETHERNET QM = QUICK MEDIA RK = RACK KIT S.F. = STERILE FIELD T.B.D. = TO BE DETERMINED U.O.N. = UNLESS OTHERWISE NOTED
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
KEYED ELECTRICAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text
AV SYSTEM DEVICE SYMBOL LEGEND
AutoCAD SHX Text
WALL
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text (WP=WALL PLATE, CP=CEILING PLATE, FP=FLOOR PLATE) JUNCTION BOX WITH CUSTOM PLATE FOR AV CONNECTION. PROVIDED BY AVC. MOUNT FLUSH WITH FINISHED BOX OR LV RING. FLOOR JB ARE SUBJECT TO POKE-THRU AND FLOOR BOX INSERTS ETC. SUB-NUMBER INDICATES NUMBER OF GANG.
AutoCAD SHX Text (BP=BOX PLATE) JUNCTION BOX WITH CUSTOM PLATE FOR A/V CONNECTIVITY. CUSTOM PLATE IS DESIGNED WITH 1" ALL AROUND LARGER FLANGE TO COVER ROUGH OPENING AT JUNCTION BOX.
AutoCAD SHX Text CAMERA LOCATION. MOUNT MAY BE TO AN INSTALLED BOX OR MOUNTING PROVIDED WITH DISPLAY MOUNT OR MILLWORK.
AutoCAD SHX Text
SPECIAL OUTLET
AutoCAD SHX Text
DATA (BUILDING LAN) SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
TV CABLE. SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
POTS TELCO ANALOG PHONE LINE
AutoCAD SHX Text
WALL MOUNTED CONTROL TOUCH PANEL
AutoCAD SHX Text
WALL MOUNTED KEY PAD
AutoCAD SHX Text
POKE THRU PLATE
AutoCAD SHX Text
MICROPHONE LOCATION
AutoCAD SHX Text
OCCUPANCY SENSOR
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
WIRELESS ACCESS POINT
AutoCAD SHX Text
INFRARED TRANSCEIVER
AutoCAD SHX Text
ELEVATION DETAIL CALL OUT. ARROW POINTS TO VIEWED DIRECTION ON DETAIL DRAWING.
AutoCAD SHX Text
DUPLEX OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
QUAD CEILING OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
SINGLE WALL OUTLET, 3 PIN EDISON
AutoCAD SHX Text SINGLE TWIST LOCK OUTLET w/RATING
AutoCAD SHX Text
REVISION NOTE
AutoCAD SHX Text
SHEET NOTE
AutoCAD SHX Text
WP
AutoCAD SHX Text
FP
AutoCAD SHX Text
CP
AutoCAD SHX Text
BP
AutoCAD SHX Text 20A
AutoCAD SHX Text 20A
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text P
AutoCAD SHX Text
JB
AutoCAD SHX Text
SCREEN CASE DRAWN TO SCALE
AutoCAD SHX Text
PROJECTOR SYMBOL NOT TO SCALE
AutoCAD SHX Text
PROJECTED LIGHT PATH
AutoCAD SHX Text
LENS CENTER LINE
AutoCAD SHX Text
CEILING MOUNTED
AutoCAD SHX Text
PROJECTOR/SCEEN
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
CEILING SPEAKER
AutoCAD SHX Text
APROX COVERAGE PATTERN 4' AFF
AutoCAD SHX Text 40°
AutoCAD SHX Text
APROX COVERAGE PATTERN
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
WALL MOUNTED SPEAKER
AutoCAD SHX Text
MOUNTING STYLES
AutoCAD SHX Text J-Box
AutoCAD SHX Text J-Box
AutoCAD SHX Text J-Box
AutoCAD SHX Text
HEIGHT AS SPECIFIED B.F.C.
AutoCAD SHX Text
JUNCTION BOX STYLES & ORIENTATIONS
AutoCAD SHX Text
HEIGHT AS SPECIFIED A.F.F.
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text J-Box
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
WALL
AutoCAD SHX Text C
AutoCAD SHX Text
DEVICE SYMBOL
AutoCAD SHX Text
CONDUCTOR TAGS AND CONDUIT SYMBOLS
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
DRAWING REFERENCE
AutoCAD SHX Text
WALL BOX MOUNTING METHODS
AutoCAD SHX Text
SLAB BOX/CONDUIT STUB-IN BOX
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT RUN, 3/4" MINIMUM U.O.N. RUN CONDUIT PER GENERAL NOTES
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text LOW VOLTAGE PLENUM CABLE RUN, OUT OF CONDUIT. CONDUIT STUBS TO ACCESSIBLE AREAS REQUIRED.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT FEED THRU, 1-1/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
SWITCH LEG
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
HOT
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
HOME RUN, 3/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
HOME CONTINUATION, 3/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT RISER-DOWN, 1" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT RISER-UP, 1" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT EXISTING/EMPTY
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT STUB-OUT, 3/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
SHOWN FOR COORDINATION ONLY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text TYPE 1G BOX = ONE GANG BOX EQUAL TO RACO 695 WITH SINGLE GANG PLASTER RING TYPE 1GS BOX = TWO GANG BOX EQUAL TO RACO 696 WITH 52-C ONE GANG PLASTER RING TYPE 2G BOX = TWO GANG BOX EQUAL TO RACO 696 WITH 52-C TWO GANG PLASTER RING TYPE 3G BOX = THREE GANG BOX EQUAL TO RACO 697 WITH 3 GANG PLASTER RING TYPE 4G BOX = FOUR GANG BOX EQUAL TO RACO 698 WITH 4 GANG PLASTER RING TYPE 5G BOX = FIVE GANG BOX EQUAL TO RACO 699 WITH 5 GANG PLASTER RING TYPE 6G BOX = SIX GANG BOX EQUAL TO RACO 965 WITH 6 GANG RACO 965 WITH 6 GANG PLASTER RING PLASTER RING LV DIVIDER = RACO 971 TYPE 1GW BOX = ONE GANG WEATHER BOX EQUAL TO CARLON E381D-CAR WITH CARLON E980 CN-CAR COVER CARLON E980 CN-CAR COVER
AutoCAD SHX Text
GANG BOX TYPES
AutoCAD SHX Text TYPE J6# JBOX = 6"x4"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J8# JBOX = 8"x8"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J10# JBOX = 10"x10"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J12# JBOX = 12"x12"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J16# JBOX = 16"x16"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J18# JBOX = 18"x18"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J24# JBOX = 16"x24"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER # INDICATES AN ALTERNATE DEPTH REQUIRED FOR THE JUNCTION BOX. UNSPECIFIED=4", 6 =6" DEEP, 8 = 8" DEEP
AutoCAD SHX Text
JUNCTION BOX TYPES
AutoCAD SHX Text
FLOOR BOX TYPES
AutoCAD SHX Text TYPE R1 RACK = MIDDLE ATLANTIC MRK-4426 OR EQUAL ON 3/4" PLYWOOD BASE PAINTED BLACK. GANG RACKS TOGETHER WHEN IN GROUPS, 24"Wx84"H EA.
AutoCAD SHX Text
RACK ENCLOSURE TYPES
AutoCAD SHX Text
CEILING LINE
AutoCAD SHX Text
FLOOR LINE
AutoCAD SHX Text
SURFACE MOUNTED
AutoCAD SHX Text
MOUNTED PROTRUDING
AutoCAD SHX Text
MOUNTED FLUSH
AutoCAD SHX Text
MOUNTED RECESS
AutoCAD SHX Text
FACE OF BOX
AutoCAD SHX Text
WP
AutoCAD SHX Text
WIRE TYPE CALL OUT LEGEND
AutoCAD SHX Text
TP
AutoCAD SHX Text
KP
AutoCAD SHX Text
AutoCAD SHX Text
AV-802
AutoCAD SHX Text
AutoCAD SHX Text
AV-802
AutoCAD SHX Text
MIC
AutoCAD SHX Text
OC
AutoCAD SHX Text
ANT
AutoCAD SHX Text
WAP
AutoCAD SHX Text
IR
AutoCAD SHX Text
ANT
AutoCAD SHX Text
WAP
AutoCAD SHX Text
1. ALL CONDUIT AND ELECTRICAL BOXES ARE TO BE BY E.C. UNLESS OTHERWISE SPECIFIED. GEM BOXES ARE ALL CONDUIT AND ELECTRICAL BOXES ARE TO BE BY E.C. UNLESS OTHERWISE SPECIFIED. GEM BOXES ARE UNACCEPTABLE FOR OUR USE. 2. ALL CONDUIT SHALL BE AT LEAST 3/4" DIAMETER UNLESS OTHERWISE SPECIFIED. ALL CONDUIT SHALL BE AT LEAST 3/4" DIAMETER UNLESS OTHERWISE SPECIFIED. 3. ALL POWER WIRING IS BY E.C. ALL POWER WIRING IS BY E.C. 4. AV CONDUIT DRAWING IS FOR THE AV SYSTEM ONLY. AV CONDUIT DRAWING IS FOR THE AV SYSTEM ONLY. 5. A PULL STRING SHALL BE INSTALLED IN EACH CONDUIT BY THE E.C. FOR USE BY THE AVC. A PULL STRING SHALL BE INSTALLED IN EACH CONDUIT BY THE E.C. FOR USE BY THE AVC. 6. ALL CONDUIT SHALL BE INSTALLED PER N.E.C. AND ANY APPLICABLE LOCAL CODES. ALL CONDUIT SHALL BE INSTALLED PER N.E.C. AND ANY APPLICABLE LOCAL CODES. 7. ANY AC DESIGNATION IS FOR REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR CIRCUIT REQUIREMENTS.ANY AC DESIGNATION IS FOR REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR CIRCUIT REQUIREMENTS.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
EXAMPLES OF AV SYMBOL BLOCKS
file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf AutoCAD SHX Text
WALL SIDE
file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf AutoCAD SHX Text
VARIOUS DISPLAY SIZES: TO SCALE W/WALL MOUNTS
AutoCAD SHX Text
WALL MOUNTED DISPLAY W/VTC CAMERA MOUNTED ABOVE
AutoCAD SHX Text
CEILING MOUNTED DISPLAY
AutoCAD SHX Text
AV EQUIPMENT RACK: TO SCALE
AutoCAD SHX Text
LECTERN
AutoCAD SHX Text
CONFERENCING SYSTEM MICROPHONE STATION
AutoCAD SHX Text
PAGING MICROPHONE
AutoCAD SHX Text
VIDEO CONFERENCING PTZ CAMERA
AutoCAD SHX Text
WALL MOUNTED 7" TOUCH PANEL
AutoCAD SHX Text
TABLE BOX: AV CONNECTIONS, POWER, LAN ETC.
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
APROX COVERAGE OVER LAP
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
HEADEND WIRE PULL
AutoCAD SHX Text
SPEAKER ZONE WIRING
AutoCAD SHX Text
LENS THROW MIN/MAX RANGE SHOWN HERE
AutoCAD SHX Text
FB TYPE 1 = POKE THRU TYPE 1 =
AutoCAD SHX Text
SPKR TYPE 1 = SPKR TYPE 2 = SPKR TYPE 3 =
AutoCAD SHX Text
SCREEN TYPE 1 = SCREEN TYPE 2 = LIFT TYPE 1 =
AutoCAD SHX Text
TP TYPE 1 =
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
BUILDING PLAN LEGEND
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AV 45492-200
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REGAN TECHNOLOGIES CORP
AutoCAD SHX Text
VA LONG BEACH, CA
AutoCAD SHX Text 45492
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
PLAN
N
EGG CONFERENCE ROOM FACILITY PLAN
1ST FLOOR
SCALE: NTS
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
1ST FLOOR - EGG CONFERENCE ROOM
AutoCAD SHX Text
FACILITY PLAN
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AV 45492-201
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REGAN TECHNOLOGIES CORP
AutoCAD SHX Text
VA LONG BEACH, CA
AutoCAD SHX Text 45492
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
FPA
SC102
+ XX" DENOTES DEVICE HEIGHT ABOVE
FINISHED FLOOR TO CENTER OF DEVICE;
UNLESS OTHERWISE NOTED
+48"
AV EQUIPMENT/DEVICES/PANELS SYMBOLS
FPA
XX-XXX
STYLE
FBA
XX-XXX
PKA
XX-XXX
DEVICE ID
CEILING
DEVICE DEVICE
FLOOR
BOX
POKE-
THRU
SPK
XX-XXX
SPA
SPK-101
SPA
SPK-102
SPA
SPK-103
SPA
SPK-104
SPA
SPK-105
SPA
SPK-106
SPA
SPK-107
SPA
SPK-108
SPA
SPK-111
SPA
SPK-112
SPA
SPK-110
SPA
SPK-113
SPA
SPK-109
SPA
SPK-114
SPA
SPK-117
SPA
SPK-116
SPA
SPK-115
SPA
SPK-126
SPA
SPK-125
SPA
SPK-124
SPA
SPK-118
SPA
SPK-119
SPA
SPK-120
SPA
SPK-123
SPA
SPK-122
SPA
SPK-121
SPB
SPK-127 GFE
SPB
SPK-128 GFE
FBA
FB-101
FBA
FB-102
FBA
FB-103
FBA
FB-104
CAM
CAM-101
CAM
CAM-103
CAM
CAM-104
TV
TV-101
TV
TV-102
TV
TV-103
TV
TV-104
PRJ
PROJ-101
ERAER-102
ERAER-101
SCN
SCN-101
EGG CONFERENCE ROOM DEVICE PLAN
D101/ D102/ D103/ D104/ D105
SCALE: NTS 2
EGG CONFERENCE ROOM RCP
D101/ D102/ D103/ D104/ D105
SCALE: NTS
WP
WP-101
APA
AP-101
APA
AP-102
CAM
CAM-102
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
TECH NOTE: EXISTING ARRAY SPEAKER RELOCATION TBD ONSITE
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
EGG CONFERENCE ROOM
AutoCAD SHX Text
DEVICE PLAN & RCP
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AV 45492-202
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REGAN TECHNOLOGIES CORP
AutoCAD SHX Text
VA LONG BEACH, CA
AutoCAD SHX Text 45492
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 04.07.25
AutoCAD SHX Text
AS-BUILTS
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
CABLE CONNECTOR ABBREVIATIONS
I��S ���� TRS �TIP�RING�SLEEVE�
���M ���� TS �TIP�SLEEVE�
���S ��������RR TRS� � COND
���M ��������RR TS� � COND
���S ���RR TRS� � COND
���M ���RR TS� � COND
#BNC BNC ��´� ��´
UDIN DIN
DP DISPLAY PORT
DUL DªSUB �������� ETC PIN
DVIY DVI� DVIªI� DVIªD
F F ��´ RF
FWU FIREWIRE
F/ F/ FIBER
HDMI HDMI
HUL HDªSUB� VGA
IR IR EMITTER
LC LC FIBER
MDP MINI DISPLAY PORT
UMD MINIªDIN
MXUL MINIªXLR
PHX PHOENIX
#RCA RCA AUDIO� VIDEO� SPDIF
R/Y R/ ��� ��� ��� ��
SC SC FIBER
SR/�� SHIELDED R/�� CONNECTOR
NLU SPEAKON
ST ST FIBER
TERM TERMINAL� BINDING POST
TOS TOSLINK
USBY USB A� B�
WALT WALTA
XLRUL XLR
SIGNAL LAYERS AND LINE STYLES
AUDIO ANALOG
AUDIO DIGITAL
CONTROL
E6UIPMENT
FIBER
LOCATION
T]�R]�DM�HDBT�EXT
RS
VIDEO ANALOG
VIDEO DIGITAL
MISC�CUSTOM
NETWORK� DATA
POWER
RADIO FRE6
SPEAKER
TEXTNOTES
DEVICE ID ABBREVIATIONS
ABBR DEVICE DESCRIPTION ABBR DEVICE DESCRIPTION
AA ANTENNA AMPLIFIER NAI NETWORK AUDIO INTERFACE
AADA ANALOG AUDIO DISTRIBUTION AMPLIFIER NC NETWORK CONTROLLER
AAP AAP MODULE NCP NETWORK CONTROL PANEL
ADC ANALOG TO DIGITAL CONVERTER NIP NETWORK INTERACTIVE PLAYER
ADP ADAPTOR NR NETWORK ROUTER
ADS ANTENNA DISTRIBUTION SYSTEM NSW NETWORK SWITCH
AI AUDIO INTERFACE NVC NETWORK CONTROL BOX
ALS ASSISTED LISTENING SYSTEM DEVICE NVD NETWORK VIDEO�AUDIO DECODER
ANT ANTENNA NVE NETWORK VIDEO�AUDIO ENCODER
APB AUDIO PATCH BAY NVS NETWORK VIDEO STREAMER
AVCP AV CONTROL PROCESSOR OS OCCUPANCY SENSOR
AVDA ANALOG VIDEO DISTRIBUTION AMPLIFIER PA AUDIO POWER AMPLIFIER
BLU BLUªRAY PLAYER PB PULL BOX
BSPL BROADCAST SPLITTER PDU POWER DISTRIBUTION UNIT
BUC BALANCED TO UNBALANCED CONVERTER PHN PHONE�CONFERENCE ACCESSORY
CAM VIDEO CAMERA POE POWER IN/ECTOR
CB CEILING BOX PRB PRESS BOX
CCU CAMERA CONTROL UNIT PS POWER SUPPLY
CFM CARD FRAME PSU POWER SE6UENCING UNIT
CM CONTROL MODULE RC REMOTE CONTROL
CONV CONVERTER RFA �RF� RADIO FRE6UENCY AMPLIFIER
CP CEILING PLATE RFC RF COMBINER
CPB CONTROL PATCH BAY RFDA RADIO FRE6 ANTENNA DISRO AMP
CPU COMPUTER ª PC ª LAPTOP RFS �RF� RADIO FRE6UENCY SPLITTER
CU CONFERENCE UNIT�CODEC� VTC� ATC� RP RACK PANEL OR RACK PLATE
CUB CABLE CUBBY RX RECEIVER INCLUDES STP OR UTP
DAC DIGITAL TO ANALOGUE CONVERTER SAT SATELLITE RECEIVER
DADA DIGITAL AUDIO DISTRIBUTION AMPLIFIER SCL SCALER
DIM DIGITAL�ANALOG INPUT MODULE SDC SINGLE DISPLAY CONTROLLER
DL DESK LOCATION SG SIGNAL GENERATOR
DMOD DEªMODULATOR SNP DIGITAL SIGNAGE PLAYER
DS DOCKING STATION SP FULL RANGE SPEAKER
DSP AUDIO DIGITAL SIGNAL PROCESSOR SPL SPLITTER
DVD DIGITAL VIDEO DISK PLAYER SPR SPEAKER RACK PANEL
DVDA DIGITAL VIDEO DISTRIBUTION AMPLIFIER SSR SOLID STATE RECORDER
EMB EMBEDDER SUB SUBWOOFER VERY LOW FRE6 SPKR
EMU EMULATOR SWR SWITCHER
ER E6UIPMENT RACK TI TABLE INTERFACE
EX EXPANDER TP TOUCH PANEL
FB FLOOR BOX TPI TOUCH PANEL INTERFACE
FEXT FIBER EXTENDER TS TEMPERATURE SENSOR
FP FLOOR PLATE TU AM�FM�TV TUNER OR CABLE SAT BOX
FPB FIBER PATCH BAY TX TRANSMITTER INCLUDES STP OR UTP
FRX FIBER OPTIC RECEIVER UAI USB AUDIO INTERFACE
FTX FIBER OPTIC TRANSMITTER UBC UNBALANCED TO BALANCED CONVERTER
GW GATEWAY UPS UNINTERRUPITBLE POWER SUPPLY
HA HEADPHONE AMPLIFIER URX USB RECEIVER ª USB EXTENDER RX
HDRX HDBT� DM� DXLINK RECEIVER USA USB TO SERIAL ADAPTER
HDTX HDBT� DM� DXLINK TRANSMITTER USW USB SWITCH
HFS HIGH FRE6UENCY SPEAKER UTX USB TRANSMITTER ª USB EXTENDER TX
HUB CONTROL SYSTEM NETWORK HUB VC VOLUME CONTROL
IPCP IP CONTROL PROCESSOR VDA VIDEO DISTRIBUTION AMPLIFIER
IRX IR RECEIVER VFC VIDEO FORMAT CONVERTER
KP KEYPAD VLD VIDEO LINE DRIVER
KVM KEYBOARD� VIDEO� MOUSE SWITCH VM VIDEO MONITOR�DISPLAY�
LFS LOW FRE6UENCY SPEAKER VP VIDEO PRO/ECTOR
LLM LINE LEVEL MODULE VPB VIDEO PATCH BAY
LLS LINE LEVEL SWITCH VS VIDEO SOURCE
LSI LIGHTING SYSTEM INTERFACE VSC VIDEO SCALER
LVC LOW VOLTAGE CONTROLLER VSW VIDEO SWITCH
MCU MIC CONTROL UNIT VWC VIDEO WALL CONTROLLER
MIC MICROPHONE WAP WIRELESS ACCESS POINT
MIP MULTI IMAGE PROC WB WALL BOX
MOD RF AGILE MODULATOR WMR WIRELESS MICROPHONE RECEIVER
MON MONITOR WMT WIRELESS MICROPHONE TRANSMITTER
MSC MISCELLANEOUS WP WALL PANEL�PLATE
MSW SATELLITE MULTISWITCH WPS WIRELESS PRESENTATION SYSTEM
MTX MATRIX SWITCHER WR WIFI ROUTER
MXR AUDIO MIXER
OTHER AV ABBREVIATIONS
AES� AUDIO ENGINEERING SOCIETY �DNLNYFQ AZINT�
AUD AUDIO
BAL BALANCED AUDIO
BB BLACK BURST
CTRL CONTROL
I�F INTERFACE
L�R LEFT�RIGHT AUDIO
M MONO FQXT � CTSI CTSSJHYTW
MFR MAUFACTURE �NFRJ TW MFPJ�
MIC MICROPHONE
MS MULTI SYNC
OFE OWNER FURNISHED E6UIPMENT
PGM PROGRAM
PLYR PLAYER
PROC PROCESSOR
REC
VR RECEIVER
RGBHV RED GREEN BLUE HORT�SYNC VERT�SYNC
R] RECEIVER
S STEREO FQXT � CTSI CTSSJHYTW
SDI SERIAL DIGITAL INTERFACE �DNLNYFQ VNIJT�
SPDIF SONY�PHILLIPS DIGITAL INTERFACE FORMAT
SPKR SPEAKER
STP SHEILED TWISTED PAIR �CAT�J� CAT��
TC TIME CODE
TRS TIP RING SLEEVE �� CTSI PMTSJ�
TS TIP SLEEVE �� CTSI ���� ���� ���� ��� PMTSJ�
T] TRANSMITTER
UNBAL UNBALANCED AUDIO
UTP UNSHEILDED TWISTED PAIR
VID VIDEO� COMPOSITE
WC WORD CLOCK
YC SªVIDEO
YRB COMPONENT� Y PG PW� Y CG CW
BULK CABLE LIST CROSS REFERENCE
FLAG
ID MFR CABLE PART # DESCRIPTION USE EXTRON WEST PENN BELDEN
� LIBERTY ��ª�CªPªBLK PLENUM ��LF��HTSI� BLK ��[��´ SPKR ª �����B ����UE
� LIBERTY ��ª�CªDBªBLK DIRECT BURIAL ��LF��HTSI� BLK ��[��´ SPKR ª ª ����A
� LIBERTY ��ª�CªDBªBLK DIRECT BURIAL ��LF��HTSI� BLK ��[��´ SPKR ª ª ����A
� LIBERTY ��ª�CªPªBLK PLENUM ��LF��HTSI� BLK ��[��´ SPKR� DC PWR ��ª���ª�� �����B ����UE
� LIBERTY ��ª�CªPªWHT PLENUM ��LF��HTSI� WHT ��[��´ SPKR� DC PWR ª �����B ����UE
� LIBERTY ��ª�CªDBªBLK DIRECT BURIAL ��LF��HTSI� BLK ��[��´ SPKR ª ����A� ����U�
� LIBERTY ��ª�CªDBªBLK DIRECT BURIAL ��LF��HTSI� BLK ��[��´ SPKR ª ����A� ����U�
� LIBERTY ��ª�CªPªBLK PLENUM ��LF��HTSI� BLK ��[ SPKR� DC PWR ��ª���ª�� �����B ����UE
� LIBERTY ��ª�CªPªBLK PLENUM ��LF��HTSI� BLK ��[ SPKR� DC PWR ª �����B ����UE
�� LIBERTY ��ª�CªPªBLK PLENUM ��LF��HTSI� BLK DC PWR� RELAY ��ª���ª�� �����B ����UE
�� LIBERTY ��ª�CªPSHªWHT PLENUM ��LF��HTSI SMNJQIJI� WHT AUDIO� CTRL� RLY ª �����B ����FE
�� LIBERTY ��ª�PªPINDSHªBLK PLENUM ��LF��UW JF� SMNJQIJI� WHT � CH AUDIO� CTRL� RLY ��ª���ª�� �����B �����
�� LIBERTY ��ª�PªPINDSHªWHT PLENUM ��LF��UW JF� SMNJQIJI� WHT � CH AUDIO� CTRL� RLY ª �����B� D����� ����PA
�� LIBERTY ��ª�PªPINDSHªWHT PLENUM ��LF��UW JF� SMNJQIJI� WHT � CH AUDIO� CTRL� RLY ª D�����
�� LIBERTY ��ª�CªPSHªBLK PLENUM ��LF��HTSI SMNJQIJI� BLK 6UAD BAL AUDIO� CTRL ª �����B ����FE
�� LIBERTY ��ª�CªPSHªWHT PLENUM ��LF��HTSI SMNJQIJI� WHT GJSJWFQ PZWUTXJ ������B ����FE
�� LIBERTY ��ª�CªPSHªWHT PLENUM ��LF��HTSI SMNJQIJI� WHT GJSJWFQ PZWUTXJ ������� ������B ����FE
�� LIBERTY ��ª�PªPªL�ªENªBLU PLENUM CAT�J ���MH_ ��LF��UW UTP USSMNJQIJI� BLU EYMJWSJY� E]YJSIJWX ª ������ ����A� ����A
�� LIBERTY ��ª�PªPªL�SHªBLK PLENUM CAT�J ���MH_ ��LF��UW STP SMNJQIJI� BLK EYMJWSJY� E]YJSIJWX� HDBFXJT!���
ª ������F ����F� ����EN
�� CRESTRON DMªCBLª�GªP PLENUM CAT�J DNLNYFQMJINF D CFGQJ STP SMNJQIJI� BLU CJWYNKNJI DNLNYFQMJINF �G� ª ª ª
�� LIBERTY ��ª�PªPªL�ªENªBLU PLENUM CAT� ���MH_ ��LF��UW U�UTP USSMNJQIJI� BLU EYMJWSJY� E]YJSIJWX� HDBFXJT#��� ª ������ ����� ��������
�� LIBERTY ��ª�PªPªL�SHªBLK PLENUM CAT� ���MH_ ��LF��UW F�UTP SMNJQIJI� BLK EYMJWSJY� HDBFXJT� E]YJSIJWX ª ������F ����F
�� LIBERTY ��ª�PªPªL�ASHªWHT PLENUM CAT�F ��LF��UW STP F�UTP SMNJQIJI� WHT �������GBFXJT� HDBFXJT� E]YJSIJWX ª ������AF ��GX��F
�� LIBERTY ��ª�PªPªL�SHªBLU PLENUM CAT�F �������GBFXJT ��LF��UW S�FTP EF PW SMNJQIJI� �������GBFXJT� HDBFXJT� E]YJSIJWX ª
�� CRESTRON DMªCBLªULTRAªP PLENUM UQYWF MNLMªGFSI\NIYM CAT�F XMNJQIJI Y\NXYJI UFNW S�FTP CJWYNKNJI DNLNYFQMJINF �G� �K ª
�� LIBERTY LLINXªUªP PLENUM ��LF��UW SMNJQIJI � ��LF��HTSI� GRAY CWJXSJY� A]QNSP� AZINT�PWR ��ª���ª��� �� D����� ����P
�� LIBERTY RG�ªPªCATVªBLK PLENUM RG� �GH_ ��´ CTF]NFQ� DZFQ SMJNQI� BLK ASFQTL VNIJT� CATV ª ������� ����� ����AP� ����P
�� LIBERTY ��ªCMPªVIDªCOAXªBLK PLENUM RG� ���GH_ ��´ CTF]NFQ� DZFQ SMJNQI� BLK DNLNYFQ VNIJT� SDI ��ª���ª��� �� ����� ����A
�� LIBERTY RG�ª6UADªCMPªWHT PLENUM RG� CCS 6ZFI SMNJQIJI RF VNIJT ��� GH_� ��LF CATV ª ��6��� ����AP� ����6�
�� LIBERTY RG��ªPªCATVªWHT PLENUM RG�� CCS DZFQ SMNJQIJI CTF]NFQ ��� GH_ CATV ª ����� ����AP
�� LIBERTY RG��ª6UADªPLªWHT PLENUM RG�� CCS 6ZFI SMNJQIJI CTF]NFQ ��� GH_ CATV ª ��6���
�� LIBERTY RGB�Cª��ªCMP PLENUM RGBHV �MHR���LF CTF]NFQ ��´� BLK ASFQTL VNIJT� YRB� RGBHV ª ������� ���CRGB ����P� ����P� ����P� RGBHV�C
�� LIBERTY RG��ªCMPªWHT PLENUM RG�� ��LF ���GH_ CTF]NFQ ��´� DZFQ SMNJQI� BLK WNWJQJXX MNHX� ALS ª ����� ������ �����
�� LIBERTY RG�ªCMPªBLK PLENUM RG� ��LF �GH_ CTF]NFQ ��´� DZFQ SMNJQI� BLK WNWJQJXX MNHX� ALS ª ª �����
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
SINGLE DEVICE BLOCK STANDARD
AutoCAD SHX Text
DEVICE ID
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MOD
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
XXXXX
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
XXXXX
AutoCAD SHX Text
MANUFACTURE
AutoCAD SHX Text
MODEL NUMBER (PART NUMBERS MAYBE ADDED AT THE BOTTOM)
AutoCAD SHX Text
DEVICE'S FUNCTION
AutoCAD SHX Text
UNIQUE DEVICE ID NUMBER (PER SYSTEM) SEE DEVICE ID ABBREVIATIONS
AutoCAD SHX Text
OUTPUT PORT W/O CONNECTOR
AutoCAD SHX Text
OUTPUT PORT WITH CONNECTOR INFO
AutoCAD SHX Text
INPUT PORT W/O CONNECTOR
AutoCAD SHX Text
INPUT PORT WITH CONNECTOR INFO
AutoCAD SHX Text 12vdc
AutoCAD SHX Text SUPPLIED w/UNIT
AutoCAD SHX Text EXTERNAL POWER SUPPLY WITH VOLTAGE, INCLUDED WITH THE DEVICE, OR OPTIONAL SUPPLY (REGULAR INTERNAL POWER CORDS ARE NOT USUALLY SHOWN
AutoCAD SHX Text
THIS INFORMATION IS PRINTED ON THE WIRE LABEL FOR EACH WIRE
AutoCAD SHX Text
OFE FLAG
AutoCAD SHX Text
CONNECTOR FOUND ON THE WIRING END OF THE CABLE. SEE CABLE CONNECTOR ABB. TABLE
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
HDTX-01 PWR
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
DEVICE, PORT
AutoCAD SHX Text
XLR3F
AutoCAD SHX Text
MIC 1
AutoCAD SHX Text
MONITOR
AutoCAD SHX Text
PORT
AutoCAD SHX Text
DEVICE ID
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
DEVICE, PORT
AutoCAD SHX Text
HDMI
AutoCAD SHX Text
PORT
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
DEVICE, PORT
AutoCAD SHX Text
SRJ45
AutoCAD SHX Text
PORT
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
DEVICE, PORT
AutoCAD SHX Text
RJ45
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
DEVICE, PORT
AutoCAD SHX Text
1BNC
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
HDTX-01 DM OUT
AutoCAD SHX Text
SRJ45
AutoCAD SHX Text
VGA
AutoCAD SHX Text
AUDIO
AutoCAD SHX Text
HDMI
AutoCAD SHX Text
HDTX-01
AutoCAD SHX Text
CRESTRON
AutoCAD SHX Text
DM-TX-200-C-2G
AutoCAD SHX Text
WALL INPUT PLATE
AutoCAD SHX Text 24vdc
AutoCAD SHX Text SUPPLIED w/UNIT
AutoCAD SHX Text
TYP I/O CONNECTOR PLATE STANDARD
AutoCAD SHX Text
WALL, FLOOR, RACK, TABLE BOX, ETC. PLATES
AutoCAD SHX Text
TYPE OF I/O PLATE
AutoCAD SHX Text
PLATE ID
AutoCAD SHX Text
PORT ENGRAVING ON PLATE
AutoCAD SHX Text
INPUT JACK
AutoCAD SHX Text
OUTPUT JACK
AutoCAD SHX Text
CALLOUT FOR PLATE DETAIL DRAWING
AutoCAD SHX Text
CONNECTOR ON THE BACK OF THE PLATE
AutoCAD SHX Text
CUSTOM MADE PLATE
AutoCAD SHX Text
DEVICE MADE PLATE
AutoCAD SHX Text
INPUT JACK
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
HDTX-01 PWR
AutoCAD SHX Text
AV RACK ER-01
AutoCAD SHX Text IF NOT POWERED LOCALLY, LOCATION IS SHOWN WHERE THE SUPPLY IS WHICH WOULD INDICATE ANOTHER WIRE WILL NEED TO BE PULLED
AutoCAD SHX Text
DEVICE LOCATION OUTLINE
AutoCAD SHX Text p = NUMBER OF PINS
AutoCAD SHX Text
# = NUMBER OF CONNECTORS
AutoCAD SHX Text g = GENDER
AutoCAD SHX Text
S = 3 CONDUCTOR
AutoCAD SHX Text t = TYPE
AutoCAD SHX Text
M = 2 CONDUCTOR
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
XXXXX
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
XXXXX
AutoCAD SHX Text
INPUT
AutoCAD SHX Text
INPUT
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
ID
AutoCAD SHX Text
ID
AutoCAD SHX Text
ID
AutoCAD SHX Text
LINES WITH RADIUS .1 BEND
AutoCAD SHX Text
= MULTIPLE WIRES
AutoCAD SHX Text
LINES STRAIGHT 90°
AutoCAD SHX Text
= SINGLE WIRE
AutoCAD SHX Text
INDICATES A CONNECTION
AutoCAD SHX Text
HAS BEEN MADE
AutoCAD SHX Text
INDICATES A SERIES
AutoCAD SHX Text
OF CONNECTIONS
AutoCAD SHX Text
INDICATES A Y CONNECTION
AutoCAD SHX Text
OR COMBINED INTO ONE JACKET
AutoCAD SHX Text
INDICATES CROSSING LINES
AutoCAD SHX Text
NO CONNECTION IS MADE
AutoCAD SHX Text
SCREW TERMINAL
AutoCAD SHX Text
CABLE END OUTPUT
AutoCAD SHX Text
CABLE END INPUT
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
APB-26
AutoCAD SHX Text
AutoCAD SHX Text
APB-19
AutoCAD SHX Text
AutoCAD SHX Text A16
AutoCAD SHX Text A17
AutoCAD SHX Text A24
AutoCAD SHX Text B24
AutoCAD SHX Text A11
AutoCAD SHX Text A12
AutoCAD SHX Text A12
AutoCAD SHX Text B12
AutoCAD SHX Text A10
AutoCAD SHX Text A16
AutoCAD SHX Text B16
AutoCAD SHX Text
VPB-03
AutoCAD SHX Text
AutoCAD SHX Text
FPB-04
AutoCAD SHX Text
AutoCAD SHX Text
OUTPUT TO
AutoCAD SHX Text
EXT SYSTEM
AutoCAD SHX Text
%%UDEVICE I/O CONNECTIONS
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
CABLE FLAGS "#" = CABLE TYPE (SEE BULK CABLE LIST)
AutoCAD SHX Text
%%UFIBER PATCH POINTS
AutoCAD SHX Text
FULL NORMAL A/B ROW
AutoCAD SHX Text
FULL NORMAL A/B ROW
AutoCAD SHX Text
IN B (LOWER) ROW
AutoCAD SHX Text
OUT A (TOP) ROW
AutoCAD SHX Text
%%UVIDEO PATCH POINTS
AutoCAD SHX Text
HALF NORMAL A/B ROW
AutoCAD SHX Text
FULL NORMAL A/B ROW
AutoCAD SHX Text
%%UAUDIO PATCH POINTS
AutoCAD SHX Text
TO EXTERNAL SYSTEM
AutoCAD SHX Text
ON PAGE
AutoCAD SHX Text
CONNECTION POINT
AutoCAD SHX Text
OFF PAGE FLAG
AutoCAD SHX Text
FROM EXTERNAL SYSTEM
AutoCAD SHX Text
OFF PAGE FLAG
AutoCAD SHX Text
DESTINATION (IN COMING)
AutoCAD SHX Text
SOURCE (OUT GOING)
AutoCAD SHX Text
%%UCONNECTION POINTS
AutoCAD SHX Text
SYMBOL KEY
AutoCAD SHX Text
BRIDGED OUTPUT
AutoCAD SHX Text
ONLY INPUT PATCH BREAKS NORMAL
AutoCAD SHX Text
EITHER PATCH BREAKS NORMAL
AutoCAD SHX Text
FROM EXT SYSTEM
AutoCAD SHX Text
BY OTHERS
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
PORT
AutoCAD SHX Text
FLAG ID
AutoCAD SHX Text
TO DWG
AutoCAD SHX Text
TO DEVICE
AutoCAD SHX Text
WIRE#
AutoCAD SHX Text
PORT
AutoCAD SHX Text
FLAG ID
AutoCAD SHX Text
FROM DWG
AutoCAD SHX Text
FROM DEVICE
AutoCAD SHX Text
MULT (OUTPUTS ONLY)
AutoCAD SHX Text
OUT A (TOP) ROW
AutoCAD SHX Text
IN B (LOWER) ROW
AutoCAD SHX Text
IN B (LOWER) ROW
AutoCAD SHX Text
OUT A (TOP) ROW
AutoCAD SHX Text
ANALOG AUDIO ONLY
AutoCAD SHX Text
ANALOG AUDIO ONLY
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
WIRE #
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
INLINE CONNECTION
AutoCAD SHX Text
DEVICE ID
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MOD
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
AutoCAD SHX Text
DEVICE ID, PORT
AutoCAD SHX Text
HDMI
AutoCAD SHX Text
DVID
AutoCAD SHX Text
INLINE ADAPTOR DIRECTLY CONNECTED TO DEVICE
AutoC…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .