S06 A0003 Extend Bid Date_RFI Responses_Job Walk Roster_36C26222B0003.pdf
PDF 44 MB Posted
- Solicitation number
- 36C26222B0003
About this file
This file contains details related to a federal solicitation to renovate a cardiology cath lab at a Department of Veterans Affairs medical center. The solicitation number is 36C26222B0003 and seeks to renovate Cardiology Cath Lab II, Project 664-CSI-116 at the Veterans Integrated Service Network 22 facility. The opportunity type is a solicitation from the Department of Veterans Affairs Veterans Health Administration to renovate the 4N Cardiology Cath Lab II at the VA Sierra Nevada Health Care System in Reno, Nevada. The file includes responses to requests for information, a job walk roster, and extends the bid date for the renovation project.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO. 1. CONTRACT ID CODE
FACILITY CODECODE
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended, is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30 PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print) (Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
0003 664-22-2-5094-0013 664-CSI-116
36C262
Department of Veterans Affairs Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
Department of Veterans Affairs Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
To all Offerors/Bidders 36C26222B0003
08-16-2022 X
X X Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1__________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified. Friday, 26 Aug 22, 2PM PDT
See CONTINUATION Page
X ONE (1)
Amendment A0003 is issued to EXTEND the Bid Due Date; include COR RFI responses; HAZMAT Report; Job Walk Sign-in Roster.
Bids are due Friday, August 26, 2022, at 2PM (PDT). Include the Solicitation # and Project Title in Email Subject Line.
A public bid opening will be held virtually on Friday, August 26, 2022, 2:15 PM (PDT), via phone (voice only).
To join the public bid opening dial: 213-282-6316, Conference ID: 658 743 911 #
- COR Responses to Contractor RFIs 1-26 w/Attachments
- HAZMAT Report, Parts 1-6
- Job Walk Sign-in Roster
SDVOSBS are required to acknowledge all issued Amendments
HARRY SEBALLOS
CONTRACTING OFFICER
VHALONSEBALH
Highlight
VHALONSEBALH
Highlight
VHALONSEBALH
Highlight
VHALONSEBALH
Highlight
VHALONSEBALH
Highlight
VHALONSEBALH
Highlight
RFI Questions & Answers
Project Name: Renovate 4N Cardiology Cath Lab II, 664-CSI-116 Solicitation Number: 36C26222B0003
Question 1
Q: Drawing Sheet GI001, Deductive Alternates lists (3) alternates. The VA did not include a Price Schedule in the contract documents. Will the VA be providing a Price Schedule for bidding, or should the offeror submit one lump sum price on the SF 1442?
A: one lump sum price
Question 2
Q: Drawing Sheet QH101, Legend has an Acquisition Code of “VF / VI” Vendor Furnished / Vendor Installed. Will the VA confirm when the term “Vendor Installed” is utilized, this is intended to mean that the VA contracted vendor will be installing those equipment items under a separate contract with the VA, and that this is not a cost or function for the Contractor, other than coordination?
A: If Vendor Furnished/Vendor Installed (VF/VI), the VA will contract with the vendor directly. Contractor will need to coordinate with Vendor for installation as it affects schedule.
Question 3
Q: Finish schedule AG602 shows Control room 4362 to receive WS-01 flooring. Finish plan on same page doesn't show WS-01 in that room. Please clarify the flooring and the transition point from 4359 Clean room to 4362 Control room.
A: Please refer to the pre-bid site walk for transition as well as the small sketch shown in below. Flooring to match existing flooring in Control Rm 4362 which is RES- 01
Question 4
Q: Finish schedule AG602 shows Corridor 4366, 4366A, and 4367 Holding to receive WS-01. These areas are shown are not shown in the area of work on finish plan AG602. Please clarify.
A: Corridor 4366, 4366A and 4367 are not in the scope of work, refer to Legend on AD102 and SOW outline.
Question 5
Q: Specification section 019100, 1.8, 1.9, and 1.10 notes the Commissioning Agent is to be appointed by the VA, and the Contractor is to appoint a Commissioning Manager. Please confirm that the VA has contracted a commissioning agent.
A: The VA is not required to hire a Commissioning agent. Contractor to hire Commissioning agent as a third-party subcontractor.
Question 6
Q: Will the VA release actual size (to scale) Drawings for this project? The current 8.5”X11” Drawings cannot be scaled by many suppliers/subcontractors.
A: No, all dwgs to be downloaded from the Solicitating web site, SAM.Gov by the contractor.
Question 7
Q: Specification Section 09 06 00 – Schedule for Finishes is completely blank except for the pre-edited outline. Will the VA provide a new Section 09 06 00 – Schedule for Finishes that has been completed?
A: See Finish Legend attached.
Question 8
Q: Specification Section 08 71 00 – Door Hardware, Part 3.5 – Hardware Sets, HW-10H states at the end that Automatic Door Operators and Controls are by Section 08 71 13. Section 08 71 13, Part 2.2-A states that the Basis of Design is Section 09 06 00, but that Section is blank. Will the VA indicate in the Door Schedule on Drawing AG601 which doors are to receive an Automatic Opener?
A: Automatic door openers are assigned to the following doors: 4358A Clean Utility, from Semi Restricted Corr.
4000, 4356A Clean Linen from Semi Restricted Corr. 4000, 4354A Cardio Cath Lab (both sides), 4354B Cardio Cath Lab (both sides) & 4000 Semi Restricted Corr. from (E) Corr. 4306. This can be seen on the Interior Elevation dwgs
17/AE702 & 12/AE703.
Question 9
Q: Drawing AG601 – Door Schedule depicts the door and card reader locations. Drawing T-124 depicts the door security device locations. There are less card reader locations depicted on Drawing AG601 than on the T-124 Security Drawing. Will the VA clarify which Drawing should be followed for the card reader locations?
A: Information on T-124 should be followed for the card reader locations.
Question 10
Q: Does the VA have a proprietary security vendor who should be used by the General Contractor for this project?
A: See attached facility standards for entry pad.
Question 11
Q: Will the VA provide information for any doors that may require a delayed egress function?
A: No doors require delayed egress function.
Question 12
Q: Will the VA clarify if any Soiled Utility Doors should have electric strikes / card readers?
A: There is no soiled utility room within the area of work.
Question 13
Q: Sheet E-101, Key Notes 1: Is the existing interstitial IT rack a 2-post rack following the rack layout shown in Sheet E-500, Diagram 5, or Sheet E-500, Diagram 6? If not, what kind of rack/cabinet is the interstitial IT rack, and what existing equipment is installed?
A: 2-post rack. There are existing 1U patch panels and 1U switches. Based on field investigations from 2020, the rack is approximately 50% full.
Question 14
Q: Sheet E-103, General Notes 3: What quantity of Cisco 9300, 48-port switches will the contractor be expected to provide and install in the existing interstitial IT rack?
A: VA OIT is the only entity authorized to purchase network switches and install them, contractor to provide all wiring drops.
Question 15
Q: Sheet E-103, General Notes 3: What duration of licenses, if necessary, will the contractor be required to provide on new Cisco 9300, 48-port switches?
A: VA OIT is the only entity authorized to purchase network switches and install them, contractor to provide all wiring drops.
Question 16
Q: Sheet E-103, General notes 3: Will new Cat6A data cabling terminate directly on new switches or onto new patch panels then patch to switches?
A: Provide patch panels ahead of all new Cisco Switches.
Question 17
Q: Sheet E-103, Key Notes 9: What size SS Utility Box will the contractor be expected to provide and install?
A: See architectural plan Detail 4/AG911 for information on SS utility box.
Question 18
Q: Are stainless steel faceplates required for 4-port telecommunications outlets?
A: No stainless steel see attached telcom outlet from EHRM project.
Question 19
Q: Spec Section 09 06 00 Schedule of Finishes does not list any information. Please provide a schedule of finishes.
A: See Finish Legend attached.
Question 20
Q: Please provide Mfg/model of acoustic ceiling tiles to be installed. Not provided in 09 06 00 Schedule of Finishes or on AG02 Finish Schedule.
A: 2’x2’ ceiling tiles (match existing) in minor public/private corridor – CertainTeed Performa RX Symphony M, 1222B-RXS-1, .70 NRC, 35 CAC TRIM-15/16 Grid System, REVEAL (Tegular), Color: white 2’x2’ ceiling tiles (match existing) in treatment/procedure rooms – CertainTeed Performa RX Symphony M, 1222B- RXS-1, .70 NRC, 35 CAC TRIM-15/16 Grid System, TRIM (flat), Color: white 2’x4’ ceiling tiles (match existing) in work room, PAC center, office– CertainTeed Performa RX Symphony M, 1222B-RXS-1, .70 NRC, 35 CAC TRIM-15/16 Grid System, TRIM (flat), Color: white
Question 21
Q: Please provide a hazmat report.
A: Contractor to download from SAM.gov.
Question 22
Q: Equipment Room 4361 was renovated during Cath Lab I. Please verify Room 4361 is not to be demo ’ed or remodelled.
A: No demo to be done.
Question 23
Q: Equipment Room 4366 does not show new flooring on the Finish Plan but calls WSF-01 on the Room Finish Schedule. Please clarify flooring in Room 4366.
A: A printing error occurred and should be fully coloured as RES-01. On Finish schedule this room is listed as XCCA1 which lists the flooring as RES-01.
Question 24
Q: The Door Schedule on Sheet AG601 calls for Hardware Set 3G for Doors 4350 and 4353. However, there isn’t Hardware Set 3G in the specification manual (Section 08 71 00).
A: Use HW-2.
Question 25
Q: Door 4000 calls for the door to be Steel material and will have a painted finish. There is a note the says “Per VA Design Guide”. However, there isn’t a Design Guide within the project files. Please confirm if this is to be a steel door, stainless steel door or a hollow metal door.
A: Hollow Metal
Question 26
Q: What is the VA’s standard manufacturers hardware for locksets? And what keyway is being used?
A: Best or Schlage with mortise configuration.
VHALONSEBALH
Highlight
ITEM CODE APPLICATION MATERIAL MANUFACTURER MODEL # COLOR NAME AREA COMMENTS
CEILING FINISH
ACT-03
CertainTeed
Performa RX
Symphony M, 1222B-RXS-1 treatment/procedure rooms RX Symphony M 2'X2' TRIM CertainTeed 1222B-RXS-1 WHITE
Performa RX Symphony M, 1222B-RXS-1, .70 NRC, 35
CAC TRIM-15/16 Grid
System
2'X2' TRIM (FLAT)
ACT-04
CertainTeed
Performa RX
Symphony M, 1222B-RXS-1 work room, PAC center, office RX Symphony M 2'X4' TRIM CertainTeed 1222B-RXS-1 WHITE
Performa RX Symphony M, 1222B-RXS-1, .70 NRC, 35
CAC TRIM-15/16 Grid
System
2'X4' TRIM (FLAT)
ACT-05
CertainTeed
Performa RX
Symphony M, 1222B-RXS-1 minor public/private corridor RX Symphony M 2'X2' TRIM CertainTeed 1222B-RXS-1 WHITE
Performa RX Symphony M, 1222B-RXS-1, .70 NRC, 35
CAC TRIM-15/16 Grid
System
2'X2' REVEAL (TEGULAR)
FLOOR FINISH AND BASE
CPT-01 INTERFACE
ARCHITECTURAL
PLANS/TO SCALE
CROSS
SECTION
WSF-01 TARKETT IQ OPTIMA
FROTHY
LATTE
RES-01 STONEHARD STONBLEND HDF TBD
PT-01 CROSSVILLE PHYSICS PHY02 NUCLEUS NON-SLIP
MONOPUR MONOPUR
MONOPUR 4+3
MONOLITHIC FLOORING
RYSEN
GRAY
RB-01 FLOOR BASE
6" JOHNSONITE ROLL RUBBER
COVE BASE
JOHNSONITE 6" COVE TBD
WALL FINISHES
P-01 WALLS PAINT FRAZEE WASHABLE EGGSHELL 501 SHELL WHITE INTERIOR WALLS WASHABLE EGG SHELL IN GENERAL AREA
P-01 WALLS PAINT FRAZEE WASHABLE EGGSHELL 501 SHELL WHITE INTERIOR WALLS SEMI-GLOSS IN WET AND CLEAN AREAS
P-02 CEILINGS PAINT FRAZEE SEMI-GLOSS 501 SHELL WHITE GWB CEILINGS
TILE
CT-01 SHOWER TILE CROSSVILLE PHYSICS PHY02 NUCLEUS SHOWER WALLS
VA SAN DIEGO FINISHES LEGEND
www.panduit.com For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see catalog back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber Optic
Systems
D.
Power over Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure Management
J.
Overhead & Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets, Racks &
Cable Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SYSTEMS
CHS2IW-X CHS2SIW-X
CHF2IW-X CHSRE2IW-X
CHS1SIW-X CHB2IW-X
CHF2MIW-X CHB2MIW-X
Component Labels for Mini-Com® Inserts
Mini-Com® Inserts
• Compatible with classic and executive faceplate frames
• Front releasable
• Accept Mini-Com ® Modules for STP and UTP, fiber optic, and audio/video, which snap in and out for easy moves, adds, and changes
‡For other colors replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Gray), or BL (Black).
Suggested Label Solutions for TIA/EIA-606-A Compliance
Insert Part Number
Laser/Ink Jet Desktop Printer Label
TDP43ME Thermal Transfer Desktop
Printer Label PanTher™ LS8E
Hand-Held Printer Label Cougar™ LS9
Hand-Held Printer Label
CHS2
C125X030FJJ C125X030YPT C125X030FJC T031X000FJC-BKCHS2S
CHSRE2
CHS1S C061X030FJJ C061X030YPT C061X030FJC T031X000FJC-BK
CHF2 C125X030FJJ C125X030YPT C125X030FJC T031X000FJC-BK
For complete labeling solutions and product information, reference charts on pages O.1 – O.22 of SA-NCCB51.
Part Number Part Description Color‡
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
CHS2IW-X Two module space, 1/2 size, sloped insert accepts two Mini-Com® Modules.
Off White
10 50
CHS2SIW-X Two module space, 1/2 size, sloped shuttered insert accepts two Mini-Com® Modules. Shutters are spring loaded and rotate out of the way for cable connections. Not suitable for use with any audio/video or fiber connector module that protrudes beyond the face of the insert.
Off White
10 50
CHF2IW-X Two module space, 1/2 size, flat insert accepts two Mini-Com® Modules.
Off White
10 50
CHSRE2IW-X Two module space, 1/2 size, 30° sloped recessed insert accepts two Mini-Com® Modules.
Off White
10 50
CHS1SIW-X One module space, 1/2 size, sloped shuttered insert accepts one Mini-Com® Module. Not suitable for use with any audio/video or fiber connector module that protrudes beyond the face of the insert.
Off White
10 50
CHB2IW-X 1/2 blank insert. Reserves space for future upgrades. Off White
10 50
CHF2MIW-X Two module space, 1/3 size, flat insert accepts two Mini-Com® Modules.
Off White
10 50
CHB2MIW-X 1/3 blank insert. Reserves space for future upgrades. Off White
10 50
CHLS2SIW-X Sloped module insert with protective shutters and label/label cover accepts up to two Mini-Com® Modules and accommodates up to 1/2 of a single gang bezel.
Shutters are spring loaded and rotate out of the way for cable connections. Depth to rear modules: 16.5mm. Not suitable for use with any audio/video or fiber connector module that protrudes beyond the face of the insert.
Off White
10 50
CHLS2SIW-X
CHB2MIW-X
CHB2MIW-X
www.pandu i t .com
Category 6/Class E Meets all TIA/EIA-568-C.2 Category 6 and ISO 11801 channel performance: 2nd Edition Class E channel requirements at swept frequencies up to 250 MHz
FCC compliance: Meets ANSI/TIA-968-A; contacts plated with 50 microinches of gold for superior performance
IEC compliance: Meets IEC 60603-7
PoE compliance: Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications
UL rated: UL 1863 approved
RoHS compliance: Compliant k e y f e a t u r e s a n d b e n e f i t s a p p l i c a t i o n s t e c h n i c a l i n f o r m a t i o n
Category 6/Class E, 8-position keystone jack module shall terminate unshielded twisted 4-pair, 22 – 26 AWG, 100 ohm cable. Punchdown tool properly terminates each conductor for optimum performance. Universal label is color-coded T568A and T568B wiring schemes.
100% performance tested Confidence that each jack module delivers specified performance
110 style punchdown Utilizes industry standard termination style and includes termination a wire retention cap
Modularity Universal keystone jack modules snap in and out of all NetKey ® Faceplates, Modular Patch Panels, and Surface Mount Boxes for fast moves, adds, and changes
Individually serialized Marked with quality control number for future traceability
Convenience packaging 25 jacks packaged in one easy to open container, (optional) eliminating the time to open each individual package and reducing on-site waste; ideal for high volume installations
Applications include:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), and 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Voice over internet protocol (VoIP)
DATA SHEET
NetKey ® Category 6 Punchdown Jack Modules
NetKey ® Category 6 Jack Modules
Module: NK688M* Convenience pack of 25 modules: NK688M*-Q
NetKey ® Category 6 Patch Cords
Foot lengths: NK6PC3**Y Meter lengths: NK6PC1M^Y
NetKey ® Category 6 Punchdown Patch Panels
12-port: NK6PPG12WY 24-port, 1 RU: NK6PPG24Y 48-port, 2 RU: NK6PPG48Y
Termination and Cable Prep Tools
Punchdown tool: PDT110‡ Punchdown base: NKSPB JackRapid +
Termination Tool: JR-PAN-2‡‡ Cable snipping tool: CWST Cable stripping tool: CJAST
*To designate a color, add suffix IW (Off White), EI (Electric Ivory), IG (Int’l Gray), WH (White), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green) or YL (Yellow).
**For standard lengths other than 3 feet (5, 7, 10, 14 or 20) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 foot patch cord is NK6PC5BUY.
^For standard lengths other than 1 meter (2, 3, 4 or 5) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (Red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 meter patch cord is NK6PC5MBUY.
‡Terminates the NetKey ® Keystone Punchdown Jack Module and NetKey ®
Patch Panel.
‡‡Terminates the NetKey ® Keystone Punchdown Jack Module. Fluke JackRapid Termination Tool available through distribution. To locate the local office, visit www.flukenetworks.com/contact.
+JackRapid is a trademark of Fluke Networks.
NetKey ® Network Components
NK688M*NK688M*NK688M
BU (Blue)BU (Blue),( ), NetKeyNetKeyy Category 6 Jack ModulesCategory 6 Jack Modulesg yy ®
©2010 Panduit Corp.
ALL RIGHTS RESERVED.
WW-NKDS09
6/2010
NetKey ® Category 6 Punchdown Jack Modules
N e t K e y ® C a t e g o r y 6 E l e c t r i c a l P e r f o r m a n c e
NEXT
Parameters
FEXT
Attenuation
Return Loss
> 46.0
@ 100 MHz
> 35.1
< 0.32
LCL > 20.0
> 16.0
Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference NKDS09
Visit us at www.panduit.com For more information
Dimensions are in inches [Dimensions in brackets are metric]
1.16 [29.50]
.63 [16.00]
.87 [22.20]
Parameters dB @ 250 MHz
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK cs-emea@panduit.com Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Jalisco, Mexico cs-la@panduit.com Phone: 52.33.3777.6000 channel performance: 2nd Edition Class E channel requirements at swept frequencies up to 250 MHz
FCC compliance: Meets ANSI/TIA-968-A; contacts plated with 50 microinches of gold for superior performance
IEC compliance: Meets IEC 60603-7
PoE compliance: Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications
UL rated: UL 1863 approved
RoHS compliance: Compliant k e y f e a t u r e s a n d b e n e f i t s a p p l i c a t i o n s t e c h n i c a l i n f o r m a t i o n
Category 6/Class E, 8-position keystone jack module shall terminate unshielded twisted 4-pair, 22 – 26 AWG, 100 ohm cable. Punchdown tool properly terminates each conductor for optimum performance. Universal label is color-coded T568A and T568B wiring schemes.
100% performance tested Confidence that each jack module delivers specified performance
110 style punchdown Utilizes industry standard termination style and includes termination a wire retention cap
Modularity Universal keystone jack modules snap in and out of all NetKey ® Faceplates, Modular Patch Panels, and Surface Mount Boxes for fast moves, adds, and changes
Individually serialized Marked with quality control number for future traceability
Convenience packaging 25 jacks packaged in one easy to open container, (optional) eliminating the time to open each individual package and reducing on-site waste; ideal for high volume installations
Applications include:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), and 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Voice over internet protocol (VoIP)
DATA SHEET
NetKey ® Category 6 Punchdown Jack Modules
NetKey ® Category 6 Jack Modules
Module: NK688M* Convenience pack of 25 modules: NK688M*-Q
NetKey ® Category 6 Patch Cords
Foot lengths: NK6PC3**Y Meter lengths: NK6PC1M^Y
NetKey ® Category 6 Punchdown Patch Panels
12-port: NK6PPG12WY 24-port, 1 RU: NK6PPG24Y 48-port, 2 RU: NK6PPG48Y
Termination and Cable Prep Tools
Punchdown tool: PDT110‡ Punchdown base: NKSPB JackRapid +
Termination Tool: JR-PAN-2‡‡ Cable snipping tool: CWST Cable stripping tool: CJAST
*To designate a color, add suffix IW (Off White), EI (Electric Ivory), IG (Int’l Gray), WH (White), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green) or YL (Yellow).
**For standard lengths other than 3 feet (5, 7, 10, 14 or 20) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 foot patch cord is NK6PC5BUY.
^For standard lengths other than 1 meter (2, 3, 4 or 5) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (Red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 meter patch cord is NK6PC5MBUY.
‡Terminates the NetKey ® Keystone Punchdown Jack Module and NetKey ®
Patch Panel.
‡‡Terminates the NetKey ® Keystone Punchdown Jack Module. Fluke JackRapid Termination Tool available through distribution. To locate the local office, visit www.flukenetworks.com/contact.
+JackRapid is a trademark of Fluke Networks.
NetKey ® Network Components
NK688M*NK688M*NK688M
WH (White)WH (White),( ), WW-NKDS09
6/2010
NetKey ® Category 6 Punchdown Jack Modules
N e t K e y ® C a t e g o r y 6 E l e c t r i c a l P e r f o r m a n c e
NEXT
Parameters
FEXT
Attenuation
Return Loss
> 46.0
@ 100 MHz
> 35.1
< 0.32
LCL > 20.0
> 16.0
Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference NKDS09
Visit us at www.panduit.com For more information
Dimensions are in inches [Dimensions in brackets are metric]
1.16 [29.50]
.63 [16.00]
.87 [22.20]
Parameters dB @ 250 MHz
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK cs-emea@panduit.com Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Jalisco, Mexico channel performance: 2nd Edition Class E channel requirements at swept frequencies up to 250 MHz
FCC compliance: Meets ANSI/TIA-968-A; contacts plated with 50 microinches of gold for superior performance
IEC compliance: Meets IEC 60603-7
PoE compliance: Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications
UL rated: UL 1863 approved
RoHS compliance: Compliant k e y f e a t u r e s a n d b e n e f i t s a p p l i c a t i o n s t e c h n i c a l i n f o r m a t i o n
Category 6/Class E, 8-position keystone jack module shall terminate unshielded twisted 4-pair, 22 – 26 AWG, 100 ohm cable. Punchdown tool properly terminates each conductor for optimum performance. Universal label is color-coded T568A and T568B wiring schemes.
100% performance tested Confidence that each jack module delivers specified performance
110 style punchdown Utilizes industry standard termination style and includes termination a wire retention cap
Modularity Universal keystone jack modules snap in and out of all NetKey ® Faceplates, Modular Patch Panels, and Surface Mount Boxes for fast moves, adds, and changes
Individually serialized Marked with quality control number for future traceability
Convenience packaging 25 jacks packaged in one easy to open container, (optional) eliminating the time to open each individual package and reducing on-site waste; ideal for high volume installations
Applications include:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), and 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Voice over internet protocol (VoIP)
DATA SHEET
NetKey ® Category 6 Punchdown Jack Modules
NetKey ® Category 6 Jack Modules
Module: NK688M* Convenience pack of 25 modules: NK688M*-Q
NetKey ® Category 6 Patch Cords
Foot lengths: NK6PC3**Y Meter lengths: NK6PC1M^Y
NetKey ® Category 6 Punchdown Patch Panels
12-port: NK6PPG12WY 24-port, 1 RU: NK6PPG24Y 48-port, 2 RU: NK6PPG48Y
Termination and Cable Prep Tools
Punchdown tool: PDT110‡ Punchdown base: NKSPB JackRapid +
Termination Tool: JR-PAN-2‡‡ Cable snipping tool: CWST Cable stripping tool: CJAST
*To designate a color, add suffix IW (Off White), EI (Electric Ivory), IG (Int’l Gray), WH (White), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green) or YL (Yellow).
**For standard lengths other than 3 feet (5, 7, 10, 14 or 20) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 foot patch cord is NK6PC5BUY.
^For standard lengths other than 1 meter (2, 3, 4 or 5) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (Red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 meter patch cord is NK6PC5MBUY.
‡Terminates the NetKey ® Keystone Punchdown Jack Module and NetKey ®
Patch Panel.
‡‡Terminates the NetKey ® Keystone Punchdown Jack Module. Fluke JackRapid Termination Tool available through distribution. To locate the local office, visit www.flukenetworks.com/contact.
+JackRapid is a trademark of Fluke Networks.
NetKey ® Network Components
NK688M*NK688M*NK688M
IG (Int’l Gray)IG (Int’l Gray),( y), WW-NKDS09
6/2010
NetKey ® Category 6 Punchdown Jack Modules
N e t K e y ® C a t e g o r y 6 E l e c t r i c a l P e r f o r m a n c e
NEXT
Parameters
FEXT
Attenuation
Return Loss
> 46.0
@ 100 MHz
> 35.1
< 0.32
LCL > 20.0
> 16.0
Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference NKDS09
Visit us at www.panduit.com For more information
Dimensions are in inches [Dimensions in brackets are metric]
1.16 [29.50]
.63 [16.00]
.87 [22.20]
Parameters dB @ 250 MHz
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK cs-emea@panduit.com Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Jalisco, Mexico channel performance: 2nd Edition Class E channel requirements at swept frequencies up to 250 MHz
FCC compliance: Meets ANSI/TIA-968-A; contacts plated with 50 microinches of gold for superior performance
IEC compliance: Meets IEC 60603-7
PoE compliance: Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications
UL rated: UL 1863 approved
RoHS compliance: Compliant k e y f e a t u r e s a n d b e n e f i t s a p p l i c a t i o n s t e c h n i c a l i n f o r m a t i o n
Category 6/Class E, 8-position keystone jack module shall terminate unshielded twisted 4-pair, 22 – 26 AWG, 100 ohm cable. Punchdown tool properly terminates each conductor for optimum performance. Universal label is color-coded T568A and T568B wiring schemes.
100% performance tested Confidence that each jack module delivers specified performance
110 style punchdown Utilizes industry standard termination style and includes termination a wire retention cap
Modularity Universal keystone jack modules snap in and out of all NetKey ® Faceplates, Modular Patch Panels, and Surface Mount Boxes for fast moves, adds, and changes
Individually serialized Marked with quality control number for future traceability
Convenience packaging 25 jacks packaged in one easy to open container, (optional) eliminating the time to open each individual package and reducing on-site waste; ideal for high volume installations
Applications include:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), and 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Voice over internet protocol (VoIP)
DATA SHEET
NetKey ® Category 6 Punchdown Jack Modules
NetKey ® Category 6 Jack Modules
Module: NK688M* Convenience pack of 25 modules: NK688M*-Q
NetKey ® Category 6 Patch Cords
Foot lengths: NK6PC3**Y Meter lengths: NK6PC1M^Y
NetKey ® Category 6 Punchdown Patch Panels
12-port: NK6PPG12WY 24-port, 1 RU: NK6PPG24Y 48-port, 2 RU: NK6PPG48Y
Termination and Cable Prep Tools
Punchdown tool: PDT110‡ Punchdown base: NKSPB JackRapid +
Termination Tool: JR-PAN-2‡‡ Cable snipping tool: CWST Cable stripping tool: CJAST
*To designate a color, add suffix IW (Off White), EI (Electric Ivory), IG (Int’l Gray), WH (White), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green) or YL (Yellow).
**For standard lengths other than 3 feet (5, 7, 10, 14 or 20) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 foot patch cord is NK6PC5BUY.
^For standard lengths other than 1 meter (2, 3, 4 or 5) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (Red) or YL (Yellow) before the Y at the end of the part number.
For example, the part number for a blue 5 meter patch cord is NK6PC5MBUY.
‡Terminates the NetKey ® Keystone Punchdown Jack Module and NetKey ®
Patch Panel.
‡‡Terminates the NetKey ® Keystone Punchdown Jack Module. Fluke JackRapid Termination Tool available through distribution. To locate the local office, visit www.flukenetworks.com/contact.
+JackRapid is a trademark of Fluke Networks.
NetKey ® Network Components
NK688M*NK688M*NK688M
g .rr g YL (Yellow)r YL (Yellow).( )
WW-NKDS09
6/2010
NetKey ® Category 6 Punchdown Jack Modules
N e t K e y ® C a t e g o r y 6 E l e c t r i c a l P e r f o r m a n c e
NEXT
Parameters
FEXT
Attenuation
Return Loss
> 46.0
@ 100 MHz
> 35.1
< 0.32
LCL > 20.0
> 16.0
Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference NKDS09
Visit us at www.panduit.com For more information
Dimensions are in inches [Dimensions in brackets are metric]
1.16 [29.50]
.63 [16.00]
.87 [22.20]
Parameters dB @ 250 MHz
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK cs-emea@panduit.com Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Jalisco, Mexico
DATA SHEET
DIGI*TRAC
Model 8 Controller Identiv DIGI*TRAC controllers are “standalone” access control systems that support:
— ScramblePad and ScrambleProx secure keypads
— MATCH intelligent reader interfaces™
— High-security alarm monitoring
— Relay control outputs When connected locally by a LAN or by telephone lines to an Identiv Host PC or server, DIGI*TRAC controllers provide a high-integrity enterprise-wide access control and security management solution.
Features Controls eight fully-supervised doors
– Both Entry and Exit
– Keypads and/or Readers Modular: Uses Expansion Boards Standalone or Networked
– Microprocessor Based
– High-Security Supervised Alarm
Inputs (2% Supervision)
– Door Relay Outputs
– General Purpose Relay Outputs
– Dedicated Alarm Relay Output
– Digital Keypad/Reader Channel Digital Transmission
– Long Wiring Runs
– Multi-drop Connections
– LAN Interface Options
– Modem Options Encryption Algorithm
– High-Security Transmission Local or Remote Programming
– ScramblePad, ScrambleProx or PC
Downloadable Firmware
– Flash Memory Printer Port Multiple Reader Technologies Resident Application Library UL Listed: 294, 1076, Grade AA
Description All DIGI*TRAC controllers have the same firmware functionality. A range of models and expansion options pro-vides a variety of access control, high security alarm monitoring, relay con-trol outputs, and programmable logic configurations to fit most applica-tions. Each unit can be a complete standalone system or a distributed controller in a larger, multi-site enter-prise system. This modular design and scalable architecture allows a system to start small and grow large.
Access Control System As an access control system, the DIGI*TRAC controller includes extensive local firmware for control sequences as basic as “who goes where and when” to sophisticated functions like two-person rule, occupancy counting, individual user tagging, door interlocking, and anti-passback.
Access may be restricted based on:
Time of Day, Day of Week, and Door. Access may be granted when the user presents the correct code, card, or both. The user may be grant-ed “temporary” access based on: Use Count Limits, Temporary Day Limits, and Absentee Rule Limits, with Auto- Disable or Auto-Delete on expiration of Temporary Users.
Additional functions include:
Unlock/Relock, Alarm Mask/Unmask, and Lock Down/Lock Down Release.
The associated door may be monitored for: Door Forced Open and Door Open Too Long, while providing Auto Relock control.
Readers supported include ScramblePad, ScrambleProx and, via the MATCH intelligent reader interface, these tech-nologies: Magnetic Stripe, Proximity, Wiegand, Bar Code, Smart Card, RF, IR, and Biometric. Technologies may be combined on the same controller or the same door in any combination.
High-Security Reader Channel The DIGI*TRAC controller supports electrically-isolated terminal blocks that provide communications and power to the ScramblePad, ScrambleProx and MATCH interfaces. The communica-tion path allows multi-drop connections for entrance and exit keypads, and dual technology applications.
User codes are digitized for transmission between an Identiv ScramblePad, ScrambleProx or MATCH and the DIGI*TRAC controller. Digital trans-mission allows longer wiring runs than are normally available with convention-al access control reader technologies.
High-Security Alarm Monitoring Identiv uses very stable digitally-processed analog inputs with 2% line supervision for high-security alarm monitoring. A line supervision module (DTLM, MELM, or SBMS) is located at the door contact, alarm sensor, request to exit (RQE), or similar device to establish this supervision.
In lieu of “shunting”, which turns off supervision, Identiv uses “alarm mask-ing” for full-time supervision and reporting of line status –– even during hours of authorized access. Conditions reported include: Alarm, Secure, RQE, Mask, Tamper Alarm, Tamper Secure, Short, Open, Noisy and Input-Out-of-Spec.
Relay Control System Relay outputs on DIGI*TRAC controllers can be used for: electric door locks and strikes, arming/disarming security systems, alarm annunciation, elevator floor control, HVAC control, lighting control, storage locker control, and many other equipment control applications. These relays may be activated by codes (via ScramblePad), cards (via MATCH and reader), time zones, alarms, or logic sequences linked to other relays.
after-hours tenant override systems. A history of who issued the override command is available for tenant billing or audit trails. The same ScramblePad used for access control can be used for tenant override and remote operator command functions.
Programmer’s Terminal DIGI*TRAC controllers can be pro-grammed by either a ScramblePad or a PC using Identiv Host software. The PC can be local or connected by LAN or modem. A ScramblePad used for access control can also be used as a programmer’s terminal. Programming functions supported include: add and delete user access codes, assign unlock/relock codes, assign alarm codes, and assign elevator control codes.
SCRAMBLE*NET ™
DIGI*TRAC controllers communicate with an Identiv Host PC using SCRAM- BLE*NET protocol which uses an encryption algorithm for high security.
The SCRAMBLE*NET command/ packet structure is ideal for LAN and hardwired paths, including RS-485 multi-drop and RS-232 via direct con-nect or dial-up modem.
COMMAND
CONTROL
MODULE (CCM)
EXPANSION
BOARD(S)
MEDECO
LOCK
KEYPAD CIRCUIT
FUSES
FUSED
POWER
SUPPLY
MEMORY
BATTERY
BACKUP
STANDBY
BATTERY
TYPICAL DOOR
TERMINAL BLOCK
HEAVY DUTY
DOOR RELAYS
RELAY STATUS
LEDS
DEDICATED
ALARM RELAYS
DIAGNOSTIC
LEDS
PARALLEL
PRINTER PORT
TAMPER
SWITCH
SNIB
MEB
AEB8
REB8
When used with a ScramblePad, DIGI*TRAC controllers are ideal for
Reliability By Design DIGI*TRAC controllers are designed for “high availability” as complete sys-tems solutions for global markets.
Standby batteries for both memory and system operation are standard. The con-troller ships with an internal internation-al power supply. All door relays are socketed. All Keypad/Reader terminals and power circuits are fused. Each unit is configured in a heavy duty, NEMA-style enclosure, with a high security lock and tamper alarm.
Specifications Communications
Serial Interface Ports:
– SCRAMBLE*NET: Requires SNIB;
encrypted message structure.
– RS-485 multi-drop or RS-232 protocol
– Optically-isolated serial port
– Baud Rate: 9600 or 19,200
– RS-485: 4000 ft (1220 m) with 22 gauge. two pair, stranded, twisted, overall shield
– RS232: 50 ft (15 m) at 9600 baud Parallel Printer Port: Standard Keypad/Reader Port: 16 device addresses
– Address 1-8 for door relay 1-8 entry;
address 9-16 for door relay 1-8 exit; any address for command and programming
– Wiring: 750 ft (160 m) with 22 gauge, 1800 ft (550 m) with 18 gauge; two pair, stranded, twisted, overall shield
Firmware Command and Control Module (CCM):
– Removable and Upgradable
– Time Zones: 150
– Access Zones: 128
– Control Zones: 256
– Holidays: Four 366 Day x 2 Years
– Daylight Savings Time Adjustment Dial-Up to Remote Host:
– Phone Numbers: four with roll-over
– User selectable retry attempts
– Call-back mode for security
– Initiation by alarm, buffer % full, and/or time
Memory Buffers: 1500 events, 1500 alarms standard
– 20,000 events, 2,000 alarms with
MEB/BE
– 20,000 events, 2,000 alarms with
MEB/CB (reduces users by 20%)
– Oldest discarded first, if full
Users: 4000 standard
– 8,000 with MEB/CE16
– 20,000 with MEB/CE32
– 68,000 with MEB/CB64
– 132,000 with MEB/CB128
Battery Backup: 30 day for code, setups, clock and buffer
Electrical Keypad/Reader Power: 8 terminals
– 1.0 Amp at 24VDC each, fused
– 2.90 Amp at 24VDC, total
– Powers ScramblePad, ScrambleProx and MATCH Primary and Standby Power:
– 90-130VAC, 50/60 Hz, fused
– 180-260VAC, 50/60 Hz, fused Uninterruptible Power Supply Standby Batteries: 7 AH Included Door Relays: 10 Amp, Form C Control Relays: 2 Amp, Form C (requires REB8) Alarm Relays: 2 Amp, Form C LEDs:
– Individual Relay Status
– Battery (OK, Low, Fail)
– AC (OK, Fail)
– System (OK, Fail)
– Keypad/MATCH (Poll, Response)
– SCRAMBLE*NET (Poll, Response)
– Test Mode
– Alarm Events in Buffer
– Box Tamper Alarm
Physical Door Tamper Switch Medeco High Security Key Lock Enclosure: NEMA-type, with conduit knockouts and removable door Dimensions: 22 x 20 x 6.25 in (55.9 x 51 x 15.9 cm) Expansion Boards:
6 x 4.25 x .75 in (15.2 x 10.8 x 1.9 cm)
Shipping Weight: 60lbs (27.2kg) Expansion Boards: 1 lb (0.45kg) Operating Temperature Range:
32° to 140° F (0° to 60° C) Relative Humidity: 0 to 90%, non-condensing
Listings and Approvals UL 294 Access Control Systems Units UL 1076 Proprietary Burglar Alarm Systems, Grade AA
CE
DTLM2
EXIT
MOV
SCRAMBLEPAD
SCRAMBLEPROX
OR MATCH
PS
LED
FUSE
SOCKETED
DOOR RELAY
TYPICAL DOOR
TERMINAL BLOCK
G + A B S
G A B S
NO C NC HI LO S
D
IG
I*
TR
A C
Typical Controller-to-Door Wiring Diagram
Ordering Information –– Controller
M8N DIGI*TRAC MODEL 8N -
8 Door - 115VAC
Controls eight supervised doors. 4000 users.
Includes eight door relays, eight alarm inputs (requires line modules), enclosure, power supply, battery, tamper switch, Medeco lock, and SNIB. Supports expansion boards. UL Listed. CE. 115VAC.
AEB8
REB8
MEB/BE
MEB/CE16
MEB/CB64
MEB/CB128
DM9600A-DL
Alarm Expansion Board - 8 Inputs
Relay Expansion Board - 8 Relays
Memory Expansion Board - Buffer Expansion
Memory Expansion Board - CODE Expansion 4,000/16,000
Memory Expansion Board - CODE Expansion of 64,000 with Buffer Option
Memory Expansion Board - CODE Expansion of 128,000 with Buffer Option
DIGI*TRAC 9600 BAUD MODEM
ASSEMBLY (Factory Set: Dial-Up Line)
Adds eight additional high security alarm inputs. SNAP, SAM and MOMENTUM support up to two boards in M2, M8, MSP or M64.
Velocity supports up to four boards in M2, M8, MSP, M64 and up to two boards in M16. Each input requires appropriate line module.
Features removable connectors. UL Listed. CE.
Adds eight additional 2 Amp Form C relays to an M2, M8, M16 or MSP-8R. May not be installed in an M64. A total of five (four if networked) REB8 boards can be installed in all other DIGI*TRAC controllers. Removable connectors and status LEDs. UL Listed. CE.
Expands standard buffer from 1500 events and 1500 alarms to 20,000 events and 2,000 alarms with CCM 7.X. Expands standard buffer from 37 events and 37 alarms (700 events and 700 alarms with CE boards) to 20,000 events and 2,000 alarms with CCM 6.6.
Protected from data loss during power failures for up to 30 days by controller memory battery. UL Listed. CE.
Expands CODE Memory from 4,000 to 8,000 on Velocity and MOMENTUM with CCM 7.X. Not recognized by SNAP or SAM with CCM 7.X. Expands CODE Memory from 1,000 to 16,000 maximum with CCM6.X. Protected from data loss during power fail-ures for up to 30 days by controller memory battery. UL Listed. CE.
Expands CODE Memory by 64,000 (from 4,000 to 68,000) with CCM 7.X on Velocity and MOMENTUM. Not recognized by CCM 6.6 or earlier. A portion of the Code Memory may be allo-cated to alarm and event Buffers on Velocity only. Protected from data loss during power failures for up to 30 days by controller memory battery. CE. UL Listed.
Expands CODE Memory by 128,000 (from 4,000 to 132,000) with CCM 7.X on Velocity and MOMENTUM. Not recognized by CCM 6.6 or earlier. A portion of the Code Memory may be allo-cated to alarm and event Buffers on Velocity only. Protected from data loss during power failures for up to 30 days by controller memory battery. CE. UL Listed.
A miniature 9600 Baud Modem Assembly that can be powered from and installed internally in the M1, M2, M8, M16 or MSP for remote site management via dial-up network. Includes cables, adaptor, and power supply harness. Do not use at Host PC or NET*MUX4 out port.
Ordering Information –– Expansion Boards and Modem
Note: The DIGI*TRAC M8 controller can accommodate up to five expansion boards. Only one MEB/CE or MEB/CB is supported per controller.
A maximum of four AEB8 expansion boards are supported per controller.
Note: Add “-230” to model number for 230 VAC.
identiv.com Revision/Date of Release: 2015-08
Identiv (NASDQ: INVE) is a global security technology company that establishes trust in the connected world, including premises, information, and everyday items. CIOs, CSOs and product departments rely upon Identiv’s trust solutions to reduce risk, achieve compliance, and protect brand identity. Identiv’s trust solutions are implemented using standards-driven products and technology, such as digital certificates, strong authentication, mobility, and cloud services.
Technical data is subject to change without notice.
Copyright © 2015 Identiv, Inc. | All rights reserved. This document is Identiv public information.
Identiv has offices worldwide. Addresses and phone numbers are listed at identiv.com/contact. For more information, visit identiv.com or email sales@identiv.com.
DescriptionModel Comments
DescriptionModel Comments
Description Altronix AL600ULX series power supply/chargers convert a 115VAC, 60Hz input into a single fused, four (4), eight (8) or sixteen (16) fuse or PTC protected outputs.
Outputs are selectable for 12VDC or 24VDC with a total of 6A max.
- Available with 1, 4, 8 or 16 outputs.
- Fused or PTC ptotected outputs.
- Supervision:
- AC Fail.
- Battery Fail and Battery Presence.
- Built-in charger for sealed lead acid or gel type batteries.
- Instantaneous transfer to stand-by batteries.
- Short circuit and overload protection.
- AC input and DC output options.
- UL Listed in the U.S. and Canada.
- CSFM and MEA Approved.
- Lifetime Warranty / Made in the U.S.A.
- All units are available in grey or red enclosure.
AL600ULX Series Power Supply/Chargers
AL600ULX Series Power Supply Configuration Reference Chart
Rev. AL600ULX-10162018
Key Features
Altronix Model Number
Total Output
Rating (A)
Input Rating:
115VAC, 60Hz
Input Fuse
Rating
Power Distribution
Module
Class 2 Rated Power-Limited
Outputs (auto-resettable)
Number of
Outputs
Fused Output Ratings
PTC
Output Ratings
Accommodates Batteries
AL600ULX
6A 3.5A 5A/250V
N/A – 1 6A – Two (2) 7AH
AL600ULXX Two (2) 12AH AL600ULPD4 PD4UL – 4 3.5A – Two (2) 7AH AL600ULPD4CB PD4ULCB 4 – 2.5A Two (2) 7AH AL600ULPD8 PD8UL – 8 3.5A – Two (2) 7AH AL600ULPD8CB PD8ULCB 8 – 2.5A Two (2) 7AH AL600ULXPD16 Two (2) PD8UL – 16 3.5A – Two (2) 12AH AL600ULXPD16CB Two (2) PD8ULCB 16 – 2.5A Two (2) 12AH
AL600ULPD8
AL600ULX Series Power Supply/Chargers
Input Voltage 115VAC, 60Hz, 3.5A max.
Fusing 5A / 250V.
Outputs Voltage 12VDC or 24VDC selectable.
Current 6A @ 12VDC or 24VDC continuous max.
Protection Fused 3.5A / PTC 2.5A.
Other Overvoltage protection.
Filtered and regulated.
Back-up Battery (not included) Capacity 7AH / 12VDC (1 or 2 within enclosure).
12AH / 12VDC (requires larger “X” enclosure).
40 AH / 65 AH (requires separate enclosure).
Type Sealed lead acid or gel type.
Failover Upon AC loss, instantaneous.
Supervision AC Failure Form “C” contacts.
Battery Form “C” contacts.
Indicators (LED) Input 115VAC is present.
DC Output Powered.
Battery Discharged or not connected.
Agency Listings All Models:
UL:
UL294 Access Control System Units.
UL1481 Power Supplies for Fire Protective Signaling Systems.
cUL:
CSA C22.2 No.205 Signal Equipment.
AL600ULX and AL600ULXX only:
CSFM California State Fire Marshall Approved.
MEA NYC Department of Buildings Approved.
FM Factory Mutual Approved.
Physical and Environmental Dimensions (H x W x D)
AL600ULX, AL600ULPD4(CB), AL600ULPD8(CB):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm).
AL600ULXX, AL600ULXPD16(CB):
15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm).
Product / Shipping Weight (approx.)
Model Product Weight Shipping Weight AL600ULX 7.05 lbs. (3.2 kg) 8.9 lbs. (4.1 kg) AL600ULXX 8.65 lbs. (3.92 kg) 10.95 lbs. (4.97 kg) AL600ULPD4(CB) 7.2 lbs. (3.27 kg) 9.05 lbs (4.1 kg) AL600ULPD8(CB) 7.3 lbs. (3.31 kg) 9.15 lbs (4.15 kg) AL600ULXPD16(CB) 8.95 lbs. (4.06 kg) 11.25 lbs. (5.1 kg)
Temperature Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage -20ºC to 70ºC (-4ºF to…
This is the start of the file's text. The full file is on GovTribe.