Atch 6 DRAWINGS Part 5.pdf
PDF 4 MB Posted
- Solicitation number
- 36C26222B0003
About this file
This document package includes construction drawings and specifications for renovating a cardiology cath lab at a Department of Veterans Affairs medical center. Key details include:
-
The project scope involves renovating Cardiology Cath Lab II, including architectural, mechanical, electrical, fire protection, and life safety work. Drawings show demolition plans, new layouts, equipment details, and fire alarm/sprinkler specifications.
-
Construction work includes updating walls, ceilings, casework, plumbing fixtures, ductwork, lighting, and adding medical equipment. Fire protection entails replacing sprinkler and alarm systems within the renovation area.
-
The solicitation for the project was issued by the VA Veterans Health Administration VISN 22 for the Z2DA--Cardiology Cath Lab II renovation under opportunity number 36C26222B0003. The estimated award date is unspecified.
-
The construction work must meet requirements of the VA Design Manual, National Fire Codes, International Building Code, and other standards. Drawings are intended for bidding and constructing the project upgrade at the VA Medical Center in San Diego, California.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DETAIL NOTES:
TO DATA OUTLETS
CA
T6
A
CA
T6
1. PROVIDE WIRING IN ACCORDANCE WITH T568A.
2. TELECOM RACKS AND CABLE TRAY ARE EXISTING TO
REMAIN.
3. TELECOM RACK ELEVATIONS ARE DIAGRAMMATIC AND DO
NOT REPRESENT EXACT EQUIPMENT LOCATIONS.
KEY NOTES:
TWO POST RACK.
2U, 48 PORT COPPER PATCH PANEL WITH CAT 6A KEYSTONES.
1U, 24 LC CONNECTOR FIBER OPTIC PATCH PANEL IN LOCKABLE
ENCLOSURE.
5 FOOT, VERTICAL RACK MOUNTED POWER DISTRIBUTION UNIT
(PDU).
2U UNINTERRUPTIBLE POWER SUPPLY
1U, 24 PORT, 110-STYLE COPPER PATCH PANEL WITH CAT6A
KEYSTONES. PROVIDE ONE PAIR PER JACK. PAIRS 24 AND 25 WILL
BE A SINGLE TWO PAIR JACK IN POSITION 24
ALL CABLE SHALL BE CAT6A.
EZ PATH FIRE STOPPING MATERIAL.
WIRE MANAGEMENT
LOOP (10 FT MINIMUM)
RACK 1
TYPICAL
RACK 1
FIBER OPTIC PATCH PANEL
WIRE MANAGEMENT
CONDUIT SLEEVES
(TYP)
UPS
WIRE MANAGEMENT
SPACE
DEDICATED
FOR VA
PROVIDED
EQUIPMENT
UPS UPS
CA
T3
ST
CA
T6
A CA
T6
A
RACK 26
CABLE TRAY
2 (TYP.)
5 (TYP.)
SPACE FOR VA PROVIDED EQUIPMENT
25 PR
24 PORT 110 STYLE PATCH PANEL
1 (TYP.)
(TYP.)
TYPICAL LAYOUT FOR RACK
SCALE: N.T.S.6TYPICAL RACK RISER DETAIL FOR TELECOMMUNICATIONS ROOMS
SCALE: 3/4" = 1'-0"5
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
No.19041 exp.3/31/2022
E L E C T R I C A LSTAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEERJO
SE
PH SCOTT DEWS , JR
E-500
DETAILS
RLF/JSD BPS/MLC
LAY IN CEILING FIXTURE MOUNTING DETAIL
SCALE: NONE1 RECESSED FIXTURE IN GYPBOARD/PLASTER CEILING DETAIL
SCALE: NONE2 HOUR CONCRETE FLOOR/WALL DETAIL
SCALE: NONE3 CONDUIT SEISMIC SEPARATION JOINT DETAIL
SCALE: NONE4
CONDUIT PENETRATION THRU 2-
W-BR
PAIR 4
31 2 4 65
W-OG W-BL OBL
PAIR 3 PAIR 1
PAIR 2
7 8
BR
RJ-45 CONNECTOR
8 POSITION/8 CONDUCTOR, CATEGORY 6A
W-G
ENCLOSURE IS EQUIPOED TO HOUSE SPLICE TRAYS (NOT SHOWN) IN REAR
COMPARTMENT AND MODULAR LC CONNECTOR PLATES ON FRONT.
TYP. 1 RMU FIBER OPTIC
SPLICING/PATCHING ENCLOSURE
TYP. FO CONNECTOR PLATE. (12
STRAND, 6 DUPLEX LC
CONNECTORS SHOWN)
TYPICAL RACK-MOUNTED FIBER OPTIC PATCH PANELS
SCALE: N.T.S.4
EIA/TIA - 568A WIRING
SCALE: N.T.S.3
TRAPEZE ON 5'-0"
CENTERS CABLE TRAY
INTERSTITIAL SPACE
WALL OUTLET
OR END DEVICE
INSULATED GROUNDED
BUSHING WITH #6 AWG TO
CABLE TRAY
1 1/4" CONDUIT TO CABLE
TRAY, (TYP.)
INSTALL CAT6A TO TELECOM
OUTLET
THREE (3) NEW CAT6A CABLE
DETAIL 4 NOTES:
1. ALL 48-PORT PATCH PANELS SHALL HAVE GRAY, BLUE, AND WHITE.
2. PATCH PANELS SHALL BE LABELED ALPHABETICALLY IN SEQUENTIAL
ORDER FROM THE TOP POSITION DOWN, STARTING WITH “A” BUT
SKIPPING “I” AND “O.”
3. SINGLE CABLE DROPS (WALL PHONES, WALL MOUNTED DISPLAY
SCREENS, ETC.) SHOULD BE TERMINATED AT THE BOTTOM OF THE
LAST PANEL, SO AS TO NOT DISRUPT THE THREE-JACK CONSECUTIVE
NUMBERING SCHEME.
4. JACKS ON THE PATCH PANELS DO NOT NEED TO BE INDIVIDUALLY
LABELED, PROVIDED THEY FOLLOW THE THREE-JACK SEQUENCE
NUMBERING SCHEME AS INDICATED ON DETAIL 3 ON SHEET T-00.52 AND
CORRESPOND TO THE FACEPLATES IN WHICH THEY ARE CONNECTED.
5. PATCH PANELS MUST BE MOUNTED WITH RJ45 TABS FACING DOWN.
TO ROOM PATCH RACK
DATA
CONNECTOR TYPE
DATA
RJ45
RJ45
CABLE TERMINATION SCHEDULE
RJ-45 CAT 6A
DATA
MODULE
(TYP OF 3)
TYPICAL DATA/TELEPHONE OUTLET
XX-XXXXX-X-XX
BUILDING NUMBER
IDF ROOM NUMBER
PATCH PANEL PORT NUMBER
PATCH PANEL
BLANK COVER
PHONE (COPPER) RJ45
COLOR
WHITE
BLUE
GRAYTELECOMMUNICATION ROOM XXX
(WHITE)(BLUE)
(GRAY)
TELECOMMUNICATION ROOM XXX
TELECOMMUNICATION ROOM XXX
DETAIL 3 NOTES:
1. DATA DROPS WILL BE IN A THREE JACK CONFIGURATION ON A FOUR PORT FACEPLATE MOUNTED ON A
SINGLE GANG BOX OR MUD RING.
2. ALL DROPS SHALL BE WIRED TO A T568A STANDARD.
3. ONLY WHITE, FOUR GANG, FLUSH MOUNT VERTICAL CLASSIC SERIES FACEPLATES SHALL BE USED.
4. FACEPLATES MUST BE MOUNTED WITH RJ45 TABS FACING DOWN.
5. FACEPLATES WILL BE LABELED IN ACCORDANCE WITH VA SPECIFICATIONS
5.1. NUMBERING CONVENTION
5.1.1. BUILDING NUMBER (WHERE APPLICABLE).
5.1.2. FLOOR, TO INCLUDE WING DESIGNATION IF APPLICABLE
5.1.3. PANEL
5.2. JACKS ARE TO BE LABELED AS: BUILDING – IDF – PATCH PANEL – JACK PORT NUMBER. FOR EXAMPLE, IN A TYPICAL 3 JACK FACEPLATE BUILDING 1, IDF ROOM NUMBER B116, PATCH PANEL C, JACK LOCATION 07 IS TO BE IDENTIFIED AS 1-B116-C-07. FROM THIS IT WILL BE ASSUMED THAT THE BLUE AND
WHITE JACKS ARE C-08 AND C-09 RESPECTIVELY.
5.3. PRIOR TO LABELING, CONTRACTOR SHALL OBTAIN APPROVAL FROM OIT REPRESENTATIVE TO ENSURE
PROPOSED NUMBERING SCHEME MEETS OIT STANDARDS.
5.4.
5.5. ALL 48-PORT PATCH PANELS SHALL HAVE GRAY, BLUE, AND WHITE.
CABLE TRAY TO OUTLET DETAIL (CAT6A)
SCALE: N.T.S.1 TELECOM OUTLET DETAIL (TYPICAL)
SCALE: N.T.S.
CAT6A PATCH PANEL
SCALE: N.T.S.5
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
No.19041 exp.3/31/2022
E L E C T R I C A LSTAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEERJO
SE
PH SCOTT DEWS , JR
E-501
DETAILS
RLF/JSD BPS/MLC
CODE SUMMARY NOTES
F-001
APPLICABLE CRITERIA
· VA DESIGN GUIDE (PG-18-12)
· VA FIRE PROTECTION DESIGN MANUAL, SIXTH EDITION SEPTEMBER 2011
· NFPA 13, 2019 EDITION
· NFPA 72, 2019 EDITION
· NFPA 101 LIFE SAFETY CODE, 2018 EDITION
· INTERNATIONAL BUILDING CODE, 2018 EDITION
AUTOMATIC FIRE SUPPRESSION AND FIRE ALARM SYSTEMS
· THE VA LA JOLLA FACILITY WILL BE PROVIDED WITH NEW FIRE ALARM
SYSTEM NOTIFICATION APPLIANCES AND INITIATING DEVICES
THROUGHOUT AS REQUIRED BY THE CATHERIZATION LAB REMODEL.
THE FIRE SPRINKLER SYSTEM WILL BE MODIFIED IN THE AREA OF THE
REMODEL AS REQUIRED BY THE NEW WALL AND CEILING LAYOUT.
SEISMIC BRACING WILL BE UPGRADED AS REQUIRED WITHIN AREA OF
PROJECT SCOPE.
SUITE REQUIREMENTS
SF: 5,198 SF < 10,000 SF TD: 100'-0" (NFPA 101 18.2.5.7.3.3)
(NFPA 101 18.2.5.7.3.2) SEPARATION: NON-RATED PARTITION THAT LIMITS
SUITE TYPE: PATIENT CARE THE TRANSFER OF SMOKE (NFPA 101 18.3.6.2)
NON-SLEEPING (NFPA 101 18.2.5.7.3)
TO BE COMBINED WITH EXISTING CATHERIZATION LAB SUITE
SEPARATION DISTANCE, ALLOWABLE AREA/HEIGHT/NUMBER OF STORIES, AND CONSTRUCTION TYPE
CONSTRUCTION TYPE: (E) TYPE IA CONSTRUCTION
SPRINKLER/ALARM: YES
OCCUPANCY TYPE: NEW HEALTHCARE (I-2)
EXISTING BUILDING: HEALTHCARE AND BUSINESS MIXED THROUGHOUT
PROJECT SCOPE: BUSINESS
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (TYPE IA CONSTRUCTION)
CLASSIFICATION OF HAZARD OF CONTENTS
· LIGHT AND ORDINARY HAZARD CONTENTS (NFPA 101 SECTION 6.2.2.3)
OCCUPANT LOAD
· REFER TO THE LIFE SAFETY EGRESS PLAN.
ARRANGEMENT AND REQUIRED NUMBER OF MEANS OF EGRESS
· REFER TO THE LIFE SAFETY EGRESS PLAN.
CAPACITY OF MEANS OF EGRESS
· CAPACITY FACTOR
DOORWAYS, PASSAGEWAYS, RAMPS: 0.20 IN./PERSON (TABLE 7.3.3.1)
STAIRS: 0.30 IN./PERSON (TABLE 7.3.3.1)
MEANS OF EGRESS COMPONENTS
DOORS
· WHERE PROVIDED, DOOR OPENINGS IN MEANS OF EGRESS SHALL NOT
BE LESS THAN 32 IN CLEAR WIDTH AND AS DETERMINED BY THE
OCCUPANT LOAD FACTOR. (NFPA 101 SECTION 7.2.1.2.3.2)
· DOOR LEAVES SHALL BE ARRANGED TO BE OPENED READILY FROM THE
EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. (NFPA 101
SECTION 7.2.1.5.1)
LOCKS, LATCHES, AND ALARM DEVICES
· DOOR LEAVES SHALL BE ARRANGED TO BE OPENED READILY FROM THE
EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. (NFPA 101
SECTION 7.2.1.5.1)
· LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, A TOOL,
OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE
EGRESS SIDE. (NFPA 101 SECTION 7.2.1.5.3)
· A LATCH OR OTHER FASTENING DEVICE ON A DOOR LEAF SHALL BE
PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS METHOD
OF OPERATION AND THAT IS READILY OPERATED UNDER ALL LIGHTING
CONDITIONS (INCLUDING COMPLETE DARKNESS). (NFPA 101 SECTION
7.2.1.5.10)
· THE RELEASING MECHANISM SHALL OPEN THE DOOR LEAF WITH NOT
MORE THAN ONE RELEASING OPERATION. (NFPA 101 SECTION 7.2.1.5.9.2)
· THE FIRE ALARM SYSTEM WILL BE INTERCONNECTED WITH ANY ACCESS
CONTROL SYSTEMS, SPECIFICALLY REQUEST TO EXIT COMPONENTS, SO
THAT POWER IS DEACTIVATED TO THOSE DOORS IN A FIRE ALARM
EVENT IN ACCORDANCE WITH NFPA 72.
CORRIDORS
· CORRIDOR WIDTHS MUST BE A MINIMUM OF 44 IN. CORRIDOR WIDTH
MUST BE A MINIMUM OF 8 FT FOR CORRIDORS USED BY PATIENTS.
· CORRIDOR WALLS WILL BE CONSTRUCTED IN ACCORDANCE WITH NFPA
101 SECTION 18.3.6.2. NO FIRE RESISTANCE RATING SHALL BE REQUIRED
FOR CORRIDOR WALLS BUT THEY SHALL FORM A BARRIER TO LIMIT THE
TRANSFER OF SMOKE.
ILLUMINATION OF MEANS OF EGRESS
· ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED
THROUGHOUT THE ENTIRE BUILDING, INCLUDING THE UNOCCUPIED
AREA. EXIT ACCESS SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES,
AND CORRIDORS LEADING TO AN EXIT. (NFPA 101 SECTION 7.8.1.1)
· THE FLOORS AND OTHER WALKING SURFACES WITHIN A EXIT AND
WITHIN THE PORTIONS OF THE EXIT ACCESS AND EXIT DISCHARGE
SHALL BE ILLUMINATED AS FOLLOWS: (NFPA 101 SECTION 7.8.1.3)
1 FT-CANDLE FOR FLOORS
10 FT-CANDLE FOR STAIRS
0.2 FT-CANDLE DUE TO FAILURE OF ANY SINGLE LIGHTING UNIT
EXIT SIGNS
· NFPA 7.10.1.5.2 NEW SIGN PLACEMENT SHALL BE SUCH THAT NO POINT IN AN EXIT ACCESS CORRIDOR IS IN EXCESS OF THE RATED VIEWING DISTANCE OR 100 FT, WHICHEVER IS LESS, FROM THE NEAREST SIGN. PRODUCT SHALL BE IN ACCORD WITH UL 924 STANDARDS. PROVIDE RECESSED CABINETS.
· EXIT SIGNS SHALL BE PROVIDED IN AREAS ACCESSIBLE TO THE PUBLIC AND WHERE AN EXIT IS NOT
IMMEDIATELY APPARENT. (NFPA 101 SECTION 7.10)
· ACCESS TO EXITS SHALL BE MARKED BY APPROVED, READILY VISIBLE SIGNS IN ALL CASES WHERE THE EXIT OR WAY TO REACH THE EXIT IS NOT READILY APPARENT TO THE OCCUPANTS. (NFPA 101
SECTION 7.10.1.5.1)
FIRE EXTINGUISHERS:
· IN ACCORDANCE WITH NFPA 10 TABLES 6.2.1.1 & 6.3.1.1 PROVIDE CLASS A & B FIRE EXTINGUISHERS
FOR USE IN THE EVENT OF FIRE. CO2 FIRE EXTINGUISHER RATING 2A:20B:C.
MEANS OF EGRESS
BUILDING CODE SUMMARY LIFE SAFETY CODE SUMMARY
SHEET LEGEND:
F-001 F-002 F-100 F-200
FA-101
FD-101
FD-102
FS-101
FS-102
FS-103
CODE SUMMARY NOTES
FIRE PROTECTION NOTES
LIFE SAFETY FLOOR PLAN
LIFE SAFETY INTERSTITIAL FLOOR PLAN
4TH FLOOR FIRE ALARM PLAN - NEW
4TH FLOOR FIRE SPRINKLER PLAN - DEMO
4TH FLOOR FIRE ALARM PLAN - DEMO
FS PARTIAL PLAN: LEVEL 4 CATHERIZATION LAB FLOOR PLAN - NEW
FS PARTIAL PLAN: LEVEL 4 CATHERIZATION LAB INTERSTITIAL - NEW
FS PARTIAL PLAN: LEVEL 3 CATHERIZATION LAB INTERSTITIAL - NEW
REQUIRED: MAX. 100'
PROVIDED: 73'-3" < 100'
COMPLIANT EXIT ACCESS CORRIDOR TO
EXIT DOOR TRAVEL DISTANCE (NO
CHANGE).
COMMON PATH TRAVEL DISTANCE:
SUITE TD:
SMOKE COMPARTMENT/EXIT TD
REQUIRED: MAX. 100'
PROVIDED: 73'-3"
REQUIRED: MAX. 200'
PROVIDED: 176'-0" (STAIR #9)
EMERGENCY ILLUMINATION OF MEANS OF EGRESS
· EMERGENCY ILLUMINATION SHALL INCLUDE ALL REQUIRED MEANS OF EGRESS LIGHTING,
ILLUMINATED EXIT SIGNS AND ALL OTHER LIGHTS SPECIFIED AS NECESSARY TO PROVIDE REQUIRED ILLUMINATION. EMERGENCY LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED SO THAT THE FAILURE OF ANY INDIVIDUAL LIGHTING ELEMENT, SUCH AS THE BURNING OUT OF A LAMP, CANNOT
LEAVE IN TOTAL DARKNESS ANY SPACE THAT REQUIRES EMERGENCY ILLUMINATION.
(NFPA 70, 2014 EDITION SECTION 700.16)
· EMERGENCY ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED. EXIT ACCESS SHALL
INCLUDE ONLY DESIGNATED STAIRS, AISLES, AND CORRIDORS LEADING TO AN EXIT. EXIT DISCHARGE SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, CORRIDORS, AND WALKWAYS LEADING TO A
PUBLIC WAY. (NFPA 101 SECTION 7.9.1.2)
· EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A MINIMUM OF 1-½ HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO NOT LESS THAN AN AVERAGE OF 0.6-FT-CANDLE AND, AT ANY POINT, NOT LESS THAN 0.06 FT-CANDLE AT THE END OF 1.5 HOURS. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT
BE EXCEEDED. (NFPA 101 SECTION 7.9.2.1)
# FEET
(# FEET MAX)
# FEET
(# FEET MAX)
ILLUMINANT EXIT SIGN
SUITE BOUNDARY LINE
AREA NOT IN CONTRACT
COMMON PATH TRAVEL DISTANCE
SUITE TRAVEL DISTANCE
FIRE-RESISTIVE CONSTRUCTION (1-HOUR)
LIFE SAFETY LEGEND
SCOPE OF WORK
PORTABLE FIRE EXTINGUISHER LOCATION,
2A:20B:C RATING MOUNTED IN SEMI
RECESSED CABINET
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
PORTABLE FIRE EXTINGUISHER LOCATION,
2A:20B:C RATING MOUNTED IN SEMI
RECESSED CABINET, EXISTING TO REMAIN
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL
F IR E P R O T E C T IO
N
FIRE PROTECTION NOTES:
DEPARTMENT OF VETERAN'S AFFAIRS (VA):
VA
VA PG-18-12
NATIONAL FIRE CODES, NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS
INCLUDING:
NFPA 1 UNIFORM FIRE CODE, 2018 EDITION
NFPA 10 PORTABLE FIRE EXTINGUISHERS, 2018 EDITION
NFPA 13 SPRINKLER SYSTEMS, 2019 EDITION
NFPA 72 NATIONAL FIRE ALARM CODE, 2019 EDITION
NFPA 101 LIFE SAFETY CODE, 2018 EDITION
FIRE PROTECTION DESIGN GUIDE
SURGICAL AND ENDOVASCULAR SERVICES DESIGN GUIDE
NFPA 70 NATIONAL ELECTRICAL CODE, 2017 EDITION
1. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA
13-2016 AND SPECIFICATION SECTION 21 13 13.
2. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL SPRINKLER SYSTEM COMPONENTS
AND COORDINATE WITH THE VARIOUS TRADES, I.E. FIRE ALARM, ELECTRICAL, ETC.
3. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED AND FM APPROVED.
4. AUTOMATIC WET PIPE SPRINKLER PROTECTION SHALL BE PROVIDED THROUGHOUT THE AREA
OF WORK.
5. PIPING SHALL BE PROVIDED WITH SEISMIC PROTECTION IN ACCORDANCE WITH NFPA 13.
BRANCH LINES SHALL BE RESTRAINED IN ACCORDANCE WITH NFPA 13.
6. SPRINKLER PIPING SHALL BE IN ACCORDANCE WITH NFPA 13. ALL PIPING AND FITTINGS SHALL
BE BLACK STEEL. PIPE SIZES LESS THAN 2.5 INCHES SHALL BE SCHEDULE 40, ALL OTHER
PIPING SHALL BE MINIMUM SCHEDULE 10. CPVC AND COPPING PIPING SHALL NOT BE
PERMITTED.
7. THE SPRINKLER DESIGN INDICATED ON THE DRAWINGS IS CONCEPTUAL AND SHOULD NOT BE
INTERPRETED TO DEPICT A COMPLETE LAYOUT OF THE SPRINKLER SYSTEM. SPRINKLER
HEAD LOCATIONS SHALL NOT BE ALTERED EXCEPT WITH THE APPROVAL OF THE ARCHITECT
AND ENGINEER. THE CONTRACTOR SHALL INSTALL THE SYSTEM IN ACCORDANCE WITH THE
APPLICABLE CODES, SPECIFICATIONS, MANUFACTURER'S RECOMMENDATIONS, AND
EQUIPMENT LISTINGS.
8. CONSTRUCTION DOCUMENTS CONSIST OF DESIGN DRAWINGS AND WRITTEN SPECIFICATIONS.
WHEREVER DISCREPANCIES OR CONFLICTS ARE FOUND BETWEEN DWG AND SPEC, THE MORE
STRINGENT REQUIREMENTS/CRITERIA SHALL GOVERN.
9. BIDDERS SHALL VISIT THE PREMISES AND THOROUGHLY FAMILIARIZE THEMSELVES WITH ALL
DETAILS OF WORK AND WORKING CONDITIONS BEFORE SUBMITTING THEIR BID. REASONABLE
MODIFICATIONS IN LOCATION AND ARRANGEMENTS TO SUIT JOB CONDITIONS SHALL NOT
CONSTITUTE BASIS FOR REQUESTING OF ADDITIONAL FUNDS FROM THE VA.
10. PRIOR TO ORDERING MATERIALS AND PROCURING EQUIPMENT, SUCCESSFUL BIDDER
(CONTRACTOR) SHALL BE REQUIRED TO VERIFY ALL EXISTING CONDITIONS, INCLUDING BUT
NOT LIMITED TO EQUIPMENT, MATERIALS, SIZES, DIMENSIONS, INVERTS, AND VOLTAGES THAT
AFFECT HIS WORK. SUBMIT A LETTER TO THE ENGINEER CONFIRMING THAT THIS WAS DONE.
IF WRITTEN CONFIRMATION IS NOT RECEIVED BY THE ENGINEER, SHOP DRAWINGS AND
OTHER SUBMITTALS WILL BE RETURNED WITHOUT REVIEW. SHOW ALL DISCREPANCIES ON
SHOP DRAWINGS AND NOTIFY THE ENGINEER IN WRITING OF SUCH DISCREPANCIES PRIOR TO
PROCUREMENT.
11. FIRE SPRINKLER HEADS AND PIPING INDICATED ON FLOOR PLANS ARE INTENDED TO SHOW
GENERAL ROUTING OF PIPING AND TO PROVIDE CONTROL OF CEILING APPEARANCE. THEY
SHOULD NOT BE INTERPRETED TO MEAN COMPLETE LAYOUT OF SPRINKLER SYSTEM. FIRE
SPRINKLER HEAD LOCATIONS SHALL NOT BE ALTERED EXCEPT WITH THE APPROVAL OF THE
ARCHITECT AND ENGINEER.
12. PROVIDE SPARE SPRINKLER HEADS, PROPER STOPPERS, AND SPECIAL SPRINKLER WRENCH
STORED IN A METAL CABINET IN THE FIRE COMMAND CENTER. SPRINKLER WRENCH TO BE
USED IN THE REMOVAL AND INSTALLATION OF SPRINKLER HEADS PER NFPA 13.
13. DESIGN SHALL BE BY A NICET LEVEL III OR IV TECHNICIAN OR A REGISTERED FIRE
PROTECTION ENGINEER. INSTALLATION SHALL BE PERFORMED BY A CERTIFIED SPRINKLER
CONTRACTOR OR A SPECIALIST WHO IS EXPERIENCED IN THE DESIGN AND INSTALLATION OF
AUTOMATIC SPRINKLER SYSTEMS (MINIMUM 3 YEARS). THE SYSTEM SHALL BE
HYDRAULICALLY CALCULATED.
14. LOCATION OF SPRINKLER HEADS: THE SPACING OF SPRINKLER HEADS SHALL NOT EXCEED
THAT PERMITTED BY NFPA 13 FOR THE HAZARD OCCUPANCY.
15. FITTINGS INTO WHICH SPRINKLER HEADS, SPRINKLER HEAD RISER NIPPLES, OR DROP NIPPLES
ARE THREADED SHALL BE WELDED, THREADED, OR GROOVED-END TYPE. PLAIN END FITTINGS
SHALL NOT BE PERMITTED. RUBBER GASKETED GROOVED-END PIPE AND FITTINGS WITH
MECHANICAL COUPLINGS SHALL BE PERMITTED IN PIPE SIZES 1.25 INCHES AND LARGER.
FITTINGS SHALL BE UL LISTED OR FM APPROVED FOR USED IN SPRINKLER SYSTEMS.
16. PIPE AND HANGER SUPPORTS: PROVIDE PIPE SUPPORTS, SWAY BRACES, HANGERS, AND
CLAMPS IN ACCORDANCE WITH NFPA 13.
17. BRANCH OUTLET FITTINGS: USE WELDED, THREADED OR GROOVED OUTLETS ONLY.
MECHANICAL FASTENED TEES ARE NOT PERMITTED. WHERE WELDED OUTLETS ARE USED,
CUTOUTS SHALL BE FASTENED TO THE PIPE FROM WHICH THEY ARE CUT.
18. SPRINKLER HEADS LOCATED IN DROP CEILING TILES SHALL NOT HAVE OVERSIZED
ESCUTCHEONS.
19. ALL SPRINKLER HEADS WITHIN SCOPE OF WORK AREA SHALL BE REMOVED AND REPLACED
WITH QUICK RESPONSE SPRINKLERS.
20. USE OF CONCEALED SPRINKLER HEADS IS STRICTLY PROHIBITED IN VETERAN'S AFFAIRS
FACILITIES.
21. PROVIDE HANGERS AT EACH SPRINKLER DROP TO PREVENT PIPE DEFLECTION.
22. THE MINIMUM DISTANCE ABOVE FINISHED FLOOR OF ALL SPRINKLER SYSTEM COMPONENTS
SHALL BE 7'-0"
1. APPLICABLE CODES AND STANDARDS
FIRE ALARM NOTES:
1. THE FIRE ALARM SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 72
(2016) AND SPECIFICATION SECTION 28 31 00.
2. ALL DEVICES AND EQUIPMENT SHALL BE U.L. LISTED OR FM APPROVED.
3. DEVICE LOCATIONS ARE CONCEPTUAL. DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.
FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE CODES,
MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS. COORDINATE LOCATIONS
WITH LIGHTING SYSTEM.
4. THE CONTRACTOR SHALL VERIFY RESPONSE PRIOR TO INSTALLATION.
5. THE EXISTING FIRE ALARM SYSTEM MANUFACTURE IS EDWARDS.
6. A NEW FIRE ALARM SYSTEM WAS REPORTED TO HAVE BEEN INSTALLED THROUGHOUT THE
BUILDING. ALL SPEAKER AND STROBE DEVICES IN THE BUILDING ARE REPORTED TO HAVE
MULTIPLE CANDELA AND WATT SETTINGS SELECTED VIA A DIPSWITCH ON THE DEVICE.
7. SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES. SYNCHRONIZE ALL AUDIBLE
NOTIFICATION APPLIANCES.
8. VISUAL NOTIFICATION APPLIANCES SHALL BE SPACED IN ACCORDANCE WITH NFPA 72.
9. ALL CIRCUITS MUST BE PULLED FROM DEVICE TO DEVICE. NO SPLICES OR T-TAPPING IS
ALLOWED.
10. CONNECTION TO CEILING MOUNTED DEVICES SHALL INCLUDE A 6'-0" FLEXIBLE CONDUIT DROP.
11. PROVIDE FIRE ALARM INITIATING AND INDICATING DEVICES THAT ARE COMPATIBLE WITH THE
EXISTING EQUIPMENT.
12. SHOP DRAWING DESIGN SHALL BE BY A NICET LEVEL III OR IV FIRE ALARM TECHNICIAN OR A
REGISTERED FIRE PROTECTION ENGINEER. INSTALLATION SHALL BE ACCOMPLISHED BY AN
ELECTRICAL CONTRACTOR WITH A MINIMUM OF FIVE YEARS EXPERIENCE IN THE INSTALLATION
OF FIRE ALARM SYSTEMS.
13. CONDUCTORS MUST MATCH EXISTING IN GAUGE, TYPE AND COLOR CODING. ALL
CONDUCTORS WHICH ARE TERMINATED, SPLICED, OR OTHERWISE INTERRUPTED IN ANY
ENCLOSURE, CABINET, MOUNTING OR JUNCTION BOX SHALL BE CONNECTED TO TERMINAL
BLOCKS. USE OF WIRE NUTS IS PROHIBITED.
14. INSTALL ALL CONDUCTORS IN RIGID METAL CONDUIT OR ELECTRICAL METALLIC TUBING, WITH
A MINIMUM DIAMETER OF 3 4 INCHES (19 MM). RUN CONDUIT OR TUBING CONCEALED UNLESS
SPECIFICALLY SHOWN OTHERWISE ON THE DRAWINGS. ALL WIRING FOR THE FIRE ALARM
SYSTEM MUST BE INSTALLED IN SEPARATE CONDUIT. NO OTHER BUILDING WIRING IS
PERMITTED IN CONDUIT THAT CONTAINS FIRE ALARM WIRING.
15. SUBMIT SHOP DRAWINGS NOT SMALLER THAN 30 INCHES BY 4A COMPLETE DESCRIPTION OF
THE SYSTEM OPERATION.
16. A COMPLETE LIST OF DEVICE ADDRESSES AND CORRESPONDING MESSAGES.
17. POINT-TO-POINT WIRING DIAGRAMS SHOWING THE POINTS OF CONNECTION AND TERMINALS
USED FOR ALL ELECTRICAL FIELD CONNECTIONS IN THE SYSTEM, INCLUDING ALL
INTERCONNECTIONS BETWEEN THE EQUIPMENT OR SYSTEMS WHICH ARE SUPERVISED OR
CONTROLLED BY THE SYSTEM.
18. INCLUDE ANNOTATED CATALOG DATA SHOWING MANUFACTURER'S NAME, MODEL, VOLTAGE,
AND CATALOG NUMBERS FOR ALL EQUIPMENT AND COMPONENTS.
19. INCLUDE BATTERY CALCULATIONS FOR BOTH THE ALARM AND SUPERVISORY POWER
REQUIREMENTS. AMPERE-HOUR REQUIREMENTS FOR EACH SYSTEM COMPONENT SHALL BE
SUBMITTED WITH THE CALCULATIONS.
20. PROVIDE A COLOR CODE SCHEDULE FOR THE WIRING AND FLOOR PLANS SHOWING THE
LOCATION OF ALL DEVICES AND EQUIPMENT.
21. THE SIGNATURE AND SEAL OF A REGISTERED PROFESSIONAL FIRE PROTECTION ENGINEER, REGISTERED PROFESSIONAL ENGINEER WITH A MINIMUM OF TWO YEARS FIRE PROTECTION
DESIGN EXPERIENCE, OR A NICET LEVEL III OR IV TECHNICIAN.
22. PRELIMINARY TESTING: CONDUCT PRELIMINARY TESTS TO ENSURE THAT ALL DEVICES AND CIRCUITS ARE FUNCTIONING PROPERLY. AFTER PRELIMINARY TESTING IS COMPLETE, PROVIDE
A LETTER CERTIFYING THAT THE INSTALLATION IS COMPLETE AND FULLY OPERABLE. THE
LETTER SHALL STATE THAT EACH INITIATING AND INDICATING DEVICE WAS TESTED IN PLACE
AND FUNCTIONED PROPERLY. THE LETTER SHALL INCLUDE THE NAMES AND TITLES OF THE
WITNESSES TO THE PRELIMINARY TESTS. THE CONTRACTOR AND AN AUTHORIZED
REPRESENTATIVE FROM EACH SUPPLIER OF EQUIPMENT SHALL BE IN ATTENDANCE AT THE
PRELIMINARY TESTING TO MAKE NECESSARY ADJUSTMENTS. A MEMBER OF THE VA COR MUST
BE INVITED TO THE PRELIMINARY TEST.
23. FINAL TESTING: NOTIFY THE CONTRACTING OFFICER IN WRITING WHEN THE SYSTEM IS READY
FOR FINAL ACCEPTANCE TESTING. SUBMIT THE REQUEST FOR TESTING AT LEAST 15
CALENDAR DAYS PRIOR TO TEST DATE. THE FINAL TESTS SHALL BE WITNESSED BY THE VA
COR. AT THIS TIME, ANY AND ALL REQUIRED TESTS SHALL BE REPEATED AT THE DISCRETION
OF THE GOVERNMENT.
24. SUBMIT AS-BUILT DRAWINGS TO THE PROJECT MANAGER UPON COMPLETION OF THE PROJECT.
THESE DRAWINGS SHALL INDICATE CHANGES FROM THE ORIGINAL LAYOUT, MARKED IN RED.
25. CONNECT TO EXISTING CIRCUITS, IF FULL, PROVIDE NEW CIRCUIT TO EXISTING FIRE ALARM
TERMINAL FOR THIS ZONE.
26. ALL FIRE ALARM WIRING SHALL BE SOLID COPPER AND INSTALLED IN CONDUIT. STRANDED
WIRING MUST NOT BE USED.
SITE MAP:
CD
S .5W
SPEAKER ONLY, WALL MOUNT
HORN ONLY, CEILING MOUNT
COMBINATION HORN / VISIBLE
CEILING MOUNTED STROBE
WALL MOUNTED STROBE
1WCD
1WCD
S C .5W
S
.5W DEMO SPEAKER ONLY, WALL
MOUNT
DEMO COMBINATION HORN /
VISIBLE
DEMO SPEAKER ONLY, CEILING
MOUNT
DEMO COMBINATION SPEAKER /
VISIBLE
DEMO CEILING MOUNTED STROBE
DEMO WALL MOUNTED STROBE
FIRE ALARM SYMBOLS:
DEVICE:
ACTION:
ANNUNCIATE ALARM AT FIRE
CONTROL PANEL
ANNUNCIATE TROUBLE AT
FIRE CONTROL PANEL
ANNUNCIATE SUPERVISORY
AT FIRE CONTROL PANEL
ACTIVATE AUDIBLE/VISUAL
ALARM SIGNAL ON
ASSOCIATED FLOOR**
TRANSMIT ALARM SIGNALS
TO CENTRAL MONITORING
STATION
TRANSMIT TROUBLE SIGNALS
TO CENTRAL MONITORING
STATION
TRANSMIT SUPERVISORY
SIGNALS TO CENTRAL
MONITORING STATION
PRIMARY ELEVATOR RECALL
ALTERNATE ELEVATOR
RECALL
FIREFIGHTER'S SERVICE
VISUAL INDICATOR
SHUNT ELEVATOR POWER
SHUT DOWN ASSOCIATED
AIR HANDLER UNIT
RELEASE DOOR HOLDERS
* NOTE: THE ACTIVATION OF ANY FIRE ALARM SIGNAL SHALL INITIATE THE FOLLOWING: 1. SHUTDOWN AIR HANDLER ON RESPECTIVE FLOOR
** NOTE: AUDIBLE AND VISUAL SIGNALING DEVICES WILL AUTOMATICALLY ACTIVATE ON THE FLOOR OF ALARM.
MANUAL PULL
STATION*
AREA SMOKE
DETECTOR*
1st FLOOR
ELEVATOR
LOBBY SMOKE
DETECTOR*
2nd-6TH
FLOOR
EXISTING SEQUENCE OF OPERATIONS
FIREELEVATOR
MACHINE
ELEVATOR
LOBBY SMOKE
DETECTOR*
ROOM SMOKE
DETECTOR*
ELEVATOR
SHUNT TRIP
120v POWER
LOSS
LOW WATER
LEVEL IN
WATER TANK
PROTECTION
WATER FLOW
SWITCH
FIRE
PROTECTION
SUPERVISORY
SWITCH
FACP POWER
FAIL & LOW
BATTERY
SYSTEM
TROUBLES
DUCT SMOKE
DETECTOR
FIRE PUMP
RUNNING
FIRE SPRINK SYMBOLS:
S SMOKE DETECTOR, CEILING
MOUNTED
DEMO SMOKE DETECTOR, CEILING
MOUNTED
NEW DUCT DETECTOR
FP DESIGNATORS:
UPRIGHT SPRINKLER
PENDENT SPRINKLER
DEMO UPRIGHT SPRINKLER
DEMO PENDENT SPRINKLER
EXISTING TO REMAIN
RELOCATE
E
R
INTERNATIONAL BUILDING CODES:
IFC 2018 INTERNATIONAL FIRE CODE
IBC 2018 INTERNATIONAL BUILDING CODE
FIRE PROTECTION NOTES
F-002
S
GREATER 12"
ALL ARM-OVER >12" HANGER REQUIRED
MAX 6"
LAY-IN ACOUSTICAL TILE
SUSPENDED CEILING
TYPICAL BRANCHLINE. SIZE
MAY VARY-SEE FLOOR PLAN
FOR SIZES AND LOCATION.
HANGER
N.T.S
1 TYPICAL ARMOVER HANGER REQUIREMENT
F002
TOP OF DETECTOR
ACCEPTABLE HERE
1' -0
" M
AX
IM
U
M
DETECTOR LOCATION
IS ACCEPTABLE HERE
BELOW ACCEPTABLE HEIGHT
ABOVE ACCEPTABLE HEIGHT
CEILING
SIDEWALL
N.T.S
2 SMOKE DETECTOR CEILING MOUNT DETAIL
F002
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL
SCOPE OF WORK
7 8 9 9.5
O
N.5
N
WORK ROOM
CLEAN UTILITY
(UCCL1)
SHOWER (TSSF1)
LOCKER (LR002)
PAC CENTER
CLEAN ROOM
(ANCW2)
CARDIO CATH LAB 2
(XCCE1)
CONTROL ROOM
CARDIO CATH LAB 2
(ORHC1)
EQUIPMENT ROOM
(CATH LAB 1)
EQUIPMENT RM 4366
XCCA1
SEMI-RESTRICTED
CORRIDOR
(E) EXAM ROOM
OFFICE
(E) SHOWER
(E) SHOWER
(E) EXAM ROOM
(E) EXAM ROOM
4342A
(E) EXAM ROOM
4339B
(E) EXAM ROOM
4339C
HOLDING
CORRIDOR
CORRIDOR
4366A
CONTROL RM (CATH
LAB 1)
(E) CATH LAB I
(E) CORRIDOR
(E) CORRIDOR
(E) OFFICES
(E) OFFICE(S)
(E) OFFICE(S)
4304A
(E) OFFICE
(E) TOILET
(E) WAITING ROOM
(E) SCRUB / DIRTY
(E) EXAM ROOM
N.25
CLEAN LINEN
(SRSE1)
08 51 13.C1 - STOREFRONT
SYSTEM
08 10 00 - DOORS AND
FRAMES
23 37 00 - AIR OUTLETS AND
INLETS
23 37 00 - AIR OUTLETS AND
INLETS
06 10 00.A1 - SOLID SURFACE
COUNTERTOP
06 10 00.A1 - SOLID SURFACE
COUNTERTOP
22 40 00.A6 - WALL MOUNT
SINK
22 40 00.A6 - WALL MOUNT
SINK
03 31 00.J1 - CONCRETE SLAB -
SEE STRUCTURAL
03 31 00.J1 - CONCRETE SLAB -
SEE STRUCTURAL
23 37 00.A2 - MECHANICAL
DUCT
23 37 00.A2 - MECHANICAL
DUCT
02 41 00.C82 - EXISTING FIRE
EXTINGUISHER
10 28 00.B17 - STAINLESS
STEEL SHELF, SURFACE
MOUNTED, 6" DEEP
10 26 00.A1 - WALL GUARD,
STAINLESS STEEL
10 26 00.A1 - WALL GUARD,
STAINLESS STEEL
10 26 00.A4 - CORNER GUARD,
STAINLESS STEEL
ALIGN
ALIGN ALIGN
SCOPE
OF WORK
SCOPE OF WORK
COMMON PATH OF TRAVEL
95 FT
(100 FT MAX)
SUITE TRAVEL DISTANCE
96 FT
(MAX 100 FT) (E)
SCOPE OF WORK
7 8 9 9.5
O
N.5
N
WORK ROOM
CLEAN UTILITY
(UCCL1)
SHOWER (TSSF1)
LOCKER (LR002)
PAC CENTER
CLEAN ROOM
(ANCW2)
CARDIO CATH LAB 2
(XCCE1)
CONTROL ROOM
CARDIO CATH LAB 2
(ORHC1)
EQUIPMENT ROOM
(CATH LAB 1)
EQUIPMENT RM 4366
XCCA1
SEMI-RESTRICTED
CORRIDOR
(E) EXAM ROOM
OFFICE
(E) SHOWER
(E) SHOWER
(E) EXAM ROOM
(E) EXAM ROOM
4342A
(E) EXAM ROOM
4339B
(E) EXAM ROOM
4339C
HOLDING
CORRIDOR
CORRIDOR
4366A
CONTROL RM (CATH
LAB 1)
(E) CATH LAB I
(E) CORRIDOR
(E) CORRIDOR
(E) OFFICES
(E) OFFICE(S)
(E) OFFICE(S)
4304A
(E) OFFICE
(E) TOILET
(E) WAITING ROOM
(E) SCRUB / DIRTY
(E) EXAM ROOM
N.25
CLEAN LINEN
(SRSE1)
08 51 13.C1 - STOREFRONT
SYSTEM
08 10 00 - DOORS AND
FRAMES
23 37 00 - AIR OUTLETS AND
INLETS
23 37 00 - AIR OUTLETS AND
INLETS
06 10 00.A1 - SOLID SURFACE
COUNTERTOP
06 10 00.A1 - SOLID SURFACE
COUNTERTOP
22 40 00.A6 - WALL MOUNT
SINK
22 40 00.A6 - WALL MOUNT
SINK
03 31 00.J1 - CONCRETE SLAB -
SEE STRUCTURAL
03 31 00.J1 - CONCRETE SLAB -
SEE STRUCTURAL
23 37 00.A2 - MECHANICAL
DUCT
23 37 00.A2 - MECHANICAL
DUCT
02 41 00.C82 - EXISTING FIRE
EXTINGUISHER
10 28 00.B17 - STAINLESS
STEEL SHELF, SURFACE
MOUNTED, 6" DEEP
10 26 00.A1 - WALL GUARD,
STAINLESS STEEL
10 26 00.A1 - WALL GUARD,
STAINLESS STEEL
10 26 00.A4 - CORNER GUARD,
STAINLESS STEEL
ALIGN
ALIGN ALIGN
SCOPE
OF WORK
SCOPE OF WORK
COMMON PATH OF TRAVEL
95 FT
(100 FT MAX)
SUITE TRAVEL DISTANCE
96 FT
(MAX 100 FT) (E)
LIFE SAFETY FLOOR PLAN
1/4"=1'-0"1
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
F-100
LIFE SAFETY FLOOR PLAN
OCCUPANT LOAD
SUITE: PATIENT CARE
NON-SLEEPING - 5,198 S.F.
SUITE ARRANGEMENT PLAN:
PATIENT CARE NON-SLEEPING
1/16"=1'-0"
G R A P H I C S C A L E
0'
1 / 16 '' = 1 ' - 0 ''
8' 32'16'
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
LIFE SAFETY SYMBOL LEGEND
# FEET
(# FEET MAX)
# FEET
(# FEET MAX)
ILLUMINANT EXIT SIGN
SUITE BOUNDARY LINE
AREA NOT IN CONTRACT
COMMON PATH TRAVEL DISTANCE
SUITE TRAVEL DISTANCE FIRE-RESISTIVE CONSTRUCTION (1-HOUR)
SCOPE OF WORK
PORTABLE FIRE EXTINGUISHER LOCATION,
2A:20B:C RATING MOUNTED IN SEMI
RECESSED CABINET, NEW
PORTABLE FIRE EXTINGUISHER LOCATION,
2A:20B:C RATING MOUNTED IN SEMI
RECESSED CABINET, EXISTING TO REMAIN
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL
SD
F
F
SD
O
N.5
N
N.25
02 41 00.E02 - EXISTING
CATWALK TO REMAIN,
PROTECT IN PLACE
03 31 00.I4 - 3-1/2""
CAST-IN-PLACE CONCRETE
SLAB W/ METAL DECKING
i400
F-200
GENERAL NOTES
LIFE SAFETY SYMBOL LEGEND
LIFE SAFETY INTERSTITIAL FLOOR PLAN
1/4"=1'-0"1
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
LIFE SAFETY INTERSTITIAL FLOOR PLAN
KEYED NOTES
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
# FEET
(# FEET MAX)
# FEET
(# FEET MAX)
ILLUMINANT EXIT SIGN
AREA NOT IN CONTRACT
COMMON PATH TRAVEL DISTANCE
SUITE TRAVEL DISTANCE
SUITE BOUNDARY LINE
FIRE-RESISTIVE CONSTRUCTION (1-HOUR)
SCOPE OF WORK
PORTABLE FIRE EXTINGUISHER LOCATION,
CLEAN AGENT, 2A:20B:C RATING MOUNTED
IN SEMI RECESSED CABINET, NEW
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
INEER
DEREK R. DUVAL
O
N.5
N
OPEN OPEN OPEN
OPEN OPEN OPEN
N.25
A
B
C
D
E
G
F
FD-101
GENERAL NOTES
LEGEND
4TH FLOOR FIRE SPRINKLER PLAN - DEMO
1/4"=1'-0"1
SCOPE OF WORK
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
E
R
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
EXISTING TO REMAIN
RELOCATE
UPRIGHT SPRINKLER
PENDENT SPRINKLER
DEMO UPRIGHT SPRINKLER
DEMO PENDENT SPRINKLER
4TH FLOOR FIRE SPRINKLER PLAN - DEMO
KEYED NOTES
DEMO ALL HEADS IN AREA OF WORK AND REPLACE WITH NEW. REFER
TO FS-101, FS-102, AND FS-103 FOR SPRINKLER HEAD TYPE AND
LOCATION.
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL
15 CD
R
15 CD
R
S E
7 8 9 9.5
O
N.5
N
OPEN OPEN OPEN
OPEN OPEN OPEN
N.25
A
B
C
D
E
G
F
GENERAL NOTES
LEGEND
SCOPE OF WORK
4TH FLOOR FIRE ALARM PLAN - DEMO
1/4"=1'-0"1
S E
S
R
S R
FIRE ALARM LEGEND
SYMBOL MODEL QTY DESCRIPTION
0 NEW FIRE ALARM STROBE
2 RELOCATE FIRE ALARM STROBE
1 EXISTING SMOKE DETECTOR
0 RELOCATE SMOKE DETECTOR
0 NEW SMOKE DETECTOR
0 NEW SPEAKER DEVICES C
.5W
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
S .5W
SPEAKER ONLY, WALL MOUNT
CEILING MOUNTED STROBE
WALL MOUNTED STROBE
1WCD
1WCD
S C .5W
S
.5W DEMO SPEAKER ONLY, WALL
MOUNT
DEMO COMBINATION HORN /
VISIBLE
DEMO SPEAKER ONLY, CEILING
MOUNT
DEMO COMBINATION SPEAKER /
VISIBLE
DEMO CEILING MOUNTED STROBE
DEMO WALL MOUNTED STROBE
FIRE ALARM SYMBOLS:
S SMOKE DETECTOR, CEILING
MOUNTED
DEMO SMOKE DETECTOR, CEILING
MOUNTED
FP DESIGNATORS:
EXISTING TO REMAIN
RELOCATE
E
R
4TH FLOOR FIRE ALARM PLAN - DEMO
FD-102
KEYED NOTES
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
CD
HORN ONLY, CEILING MOUNT
COMBINATION HORN / VISIBLE
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
INEER
DEREK R. DUVAL
GE
O.1
O
N.5
N
CLEAN UTILITY
(UCCL1)
LOCKER (LR002)
(E) CATH LAB I
CARDIO CATH LAB 2
(XCCE1)
4354CLEAN ROOM
(ANCW2)
CONTROL ROOM
CARDIO CATH LAB 2
(ORHC1)
CONTROL RM (CATH
LAB 1)
SHOWER (TSSF1)
PAC CENTER
SEMI-RESTRICTED
CORRIDOR
(E) CORRIDOR
(E) OFFICES
(E) OFFICE(S)
(E) OFFICE(S)
4304A
(E) OFFICE
(E) TOILET
(E) WAITING ROOM
(E) CORRIDOR
(E) EXAM ROOM
EQUIPMENT RM 4366
XCCA1
HOLDING
CORRIDOR
(E) SCRUB / DIRTY
CORRIDOR
4366A
EQUIPMENT ROOM
(CATH LAB 1)
N.25
WORK ROOM
CLEAN LINEN
(SRSE1)
9' - 5 3/16" A.F.F.
9' - 0" A.F.F.
9' - 0" A.F.F.
OFFICE
9' - 0" A.F.F.
9' - 0" A.F.F.
9' - 0" A.F.F.
9' - 0" A.F.F.9' - 6" A.F.F.
8' - 6" A.F.F.
9' - 0" A.F.F.
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System
8' - 6"
9' - 0" A.F.F.
8' - 2" A.F.F.
9' - 0" A.F.F.
GE018
GE019
GE019
GE019
GE019
GE019
GE019
ORDINARY HAZARD
GROUP 2
1 1
1 1
ORDINARY HAZARD
GROUP I
ORDINARY HAZARD
GROUP I
FS-101
GENERAL NOTES
LEGEND
4TH FLOOR FIRE SPRINKLER PLAN
1/4"=1'-0"1
SCOPE OF WORK
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
E
R
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
EXISTING TO REMAIN
RELOCATE
UPRIGHT SPRINKLER
PENDENT SPRINKLER
DEMO UPRIGHT SPRINKLER
DEMO PENDENT SPRINKLER
E
R
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
EXISTING TO REMAIN
RELOCATE
UPRIGHT SPRINKLER
PENDENT SPRINKLER
DEMO UPRIGHT SPRINKLER
DEMO PENDENT SPRINKLER
1 CONTRACTOR TO COORDINATE EXISTING SPRINKLER HEAD LOCATIONS
WITHIN NEW CATH LAB SPACE TO ORDINARY HAZARD GROUP 1
REQUIREMENTS. COORDINATE SPACE WITH ELECTRICAL AND
MECHANICAL DISCIPLINES. SEE ARCHITECTURAL, ELECTRICAL AND
MECHANICAL DRAWINGS FOR FURTHER DETAILS.
4TH FLOOR FIRE SPRINKLER PLAN
KEYED NOTES
PROVIDE BRANCH LINE AND FIELD VERIFY FOR NEW SPRINKLER HEADS.2
FIRE SPRINKLER CONTROL VALVE LOCATED IN INTERSTITIAL SPACE
ADJACENT TO STAIR 9.
ALL AREAS ARE LIGHT HAZARD UNLESS OTHERWISE NOTED.4
MAXIMUM PROTECTION AREA AND SPACING:
LIGHT HAZARD:
MAXIMUM PROTECTION AREA PER SPRINKLER: 225 SQ.FT.
MAXIMUM SPACING BETWEEN SPRINKLERS: 15 FT
ORDINARY HAZARD:
MAXIMUM PROTECTION AREA PER SPRINKLER: 130 SQ.FT.
MAXIMUM SPACING BETWEEN SPRINKLERS: 15 FT
1 PROVIDE CORROSION RESISTANT FINISH
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
SYMBOL MODEL QTY TYP TEMP RESPONSE ESCHUCHEON
35 155 QR
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL
SD
F
F
SD
O
N.5
N
N.25
02 41 00.E02 - EXISTING
CATWALK TO REMAIN,
PROTECT IN PLACE
03 31 00.I4 - 3-1/2""
CAST-IN-PLACE CONCRETE
SLAB W/ METAL DECKING
i400
1" 1" 1" 1"
1"
1" 1" 1" 1"
1" 1" 1" 1"
1" 1" 1" 1"
1" 1" 1" 1"
1" 1" 1"
1"
1" 1" 1"
1"
1"
1"
3" 3"
3" 3"
3" 3"
3" 3"
1"
1"
FS-102
GENERAL NOTES
LEGEND
4TH FLOOR INTERSTITIAL FIRE SPRINKLER PLAN
1/4"=1'-0"1
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
EXISTING SPRINKLER PIPING
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
NEW SPRINKLER PIPING
SCOPE OF WORK
4TH FLOOR INTERSTITIAL FIRE SPRINKLER PLAN
EXTEND EXISTING BRANCHLINE
FOR NEW SPRINKLER HEADS
KEYED NOTES
PROVIDE BRANCH LINE AND FIELD VERIFY FOR NEW SPRINKLER HEADS.1
NEW SPRINKLER BRANCH LINE PIPING TO MATCH EXISTING.2
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
UPRIGHT SPRINKLER
REMOVE TO SOURCE AND PROVIDE NEW BRANCHLINE TO BELOW NEW
MECHANICAL ROOM
EXTEND NEW 1" BRANCHLINES FOR SPRINKLER PROTECTION IN NEW
MECHANICAL ROOM. COORDINATE WITH MECHANICAL IN CATWALK.
SPRINKLER LEGEND
SYMBOL MODEL QTY TYP TEMP RESPONSE ESCHUCHEON
8 155 QR
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
INEER
DEREK R. DUVAL
7 8 9
FS-103
GENERAL NOTES
LEGEND
3RD FLOOR INTERSTITIAL FIRE SPRINKLER PLAN
1/2"=1'-0"1
G R A P H I C S C A L E 0'
1 / 2 '' = 1 ' - 0 ''
1' 4'2'
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
EXISTING SPRINKLER PIPING
FIRE SPRINK SYMBOLS: FP DESIGNATORS:
NEW SPRINKLER PIPING
3RD FLOOR INTERSTITIAL FIRE SPRINKLER PLAN
KEYED NOTES
PROVIDE BRANCH LINE AND FIELD VERIFY FOR NEW SPRINKLER HEADS.1
NEW SPRINKLER BRANCH LINE PIPING TO MATCH EXISTING.2
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
PENDANT SPRINKLER
SPRINKLER LEGEND
SYMBOL MODEL QTY TYP TEMP RESPONSE ESCHUCHEON
8 155 QR
PROVIDE COVERAGE IN CEILING POCKETS
NEW SPRINKLER PIPING TO EXTEND FROM EXISTING PIPING
PROVIDE COVERAGE IN CEILING POCKETS
NEW SPRINKLER PIPING TO EXTEND FROM EXISTING PIPING
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL
O
N.5
N
WORK ROOM
CLEAN UTILITY
(UCCL1)
SHOWER (TSSF1)
LOCKER (LR002)
PAC CENTER
CLEAN ROOM
(ANCW2)
CARDIO CATH LAB 2
(XCCE1)
CONTROL ROOM
CARDIO CATH LAB 2
(ORHC1)
EQUIPMENT ROOM
(CATH LAB 1)
EQUIPMENT RM 4366
XCCA1
SEMI-RESTRICTED
CORRIDOR
(E) EXAM ROOM
OFFICE
(E) SHOWER
(E) SHOWER
(E) EXAM ROOM
(E) EXAM ROOM
4342A
(E) EXAM ROOM
4339B
(E) EXAM ROOM
4339C
HOLDING
CORRIDOR
CORRIDOR
4366A
CONTROL RM (CATH
LAB 1)
(E) CATH LAB I
(E) CORRIDOR
(E) CORRIDOR
(E) OFFICES
(E) OFFICE(S)
(E) OFFICE(S)
4304A
(E) OFFICE
(E) TOILET
(E) WAITING ROOM
(E) SCRUB / DIRTY
(E) EXAM ROOM
N.25
CLEAN LINEN
(SRSE1)
08 51 13.C1 - STOREFRONT
SYSTEM
08 10 00 - DOORS AND
FRAMES
23 37 00 - AIR OUTLETS AND
INLETS
23 37 00 - AIR OUTLETS AND
INLETS
06 10 00.A1 - SOLID SURFACE
COUNTERTOP
06 10 00.A1 - SOLID SURFACE
COUNTERTOP
22 40 00.A6 - WALL MOUNT
SINK
22 40 00.A6 - WALL MOUNT
SINK
03 31 00.J1 - CONCRETE SLAB -
SEE STRUCTURAL
03 31 00.J1 - CONCRETE SLAB -
SEE STRUCTURAL
23 37 00.A2 - MECHANICAL
DUCT
23 37 00.A2 - MECHANICAL
DUCT
02 41 00.C82 - EXISTING FIRE
EXTINGUISHER
10 28 00.B17 - STAINLESS
STEEL SHELF, SURFACE
MOUNTED, 6" DEEP
10 26 00.A1 - WALL GUARD,
STAINLESS STEEL
10 26 00.A1 - WALL GUARD,
STAINLESS STEEL
10 26 00.A4 - CORNER GUARD,
STAINLESS STEEL
30 CD
R
15 CD
R
15 CD
15 CD
S E
S
15 CD
GENERAL NOTES
LEGEND
4TH FLOOR FIRE ALARM PLAN - NEW
1/4"=1'-0"1
S E
S
R
S R
S C .5W
G R A P H I C S C A L E 0'
1 / 4 '' = 1 ' - 0 ''
2' 8'4'
CD
S SPEAKER ONLY, WALL MOUNT
HORN ONLY, CEILING MOUNT
COMBINATION HORN / VISIBLE
CEILING MOUNTED STROBE
WALL MOUNTED STROBE
1WCD
1WCD
S C .5W
S
.5W DEMO SPEAKER ONLY, WALL
MOUNT
DEMO COMBINATION HORN /
VISIBLE
DEMO SPEAKER ONLY, CEILING
MOUNT
DEMO COMBINATION SPEAKER /
VISIBLE
DEMO CEILING MOUNTED STROBE
DEMO WALL MOUNTED STROBE
FIRE ALARM SYMBOLS:
S SMOKE DETECTOR, CEILING
MOUNTED
DEMO SMOKE DETECTOR, CEILING
MOUNTED
NEW DUCT DETECTOR
FP DESIGNATORS:
EXISTING TO REMAIN
RELOCATE
E
R
SCOPE OF WORK
CONTRACTOR TO COORDINATE FIRE ALARM SYSTEM DEVICE LOCATIONS
WITHIN NEW CATH LAB SPACE WITH ELECTRICAL AND MECHANICAL.
SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR DETAILS.
4TH FLOOR FIRE ALARM PLAN - NEW
FA-101
S
FIRE ALARM LEGEND
SYMBOL MODEL QTY DESCRIPTION
2 NEW FIRE ALARM STROBE
2 RELOCATE FIRE ALARM STROBE
0 EXISTING SMOKE DETECTOR
0 RELOCATE SMOKE DETECTOR
0 NEW SMOKE DETECTOR
1 NEW SPEAKER DEVICE
1 NEW DUCT DETECTORS
KEYED NOTES
1 PROVIDE NEW SMOKE DUCT DETECTOR FOR AHU-401 - LOCATED
IN INTERSTITIAL SPACE. CONTRACTOR TO COORDINATE WITH
FIELD CONDITIONS.
FEC
FEC
FEC
CAB DESK
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
KEY PLAN
08 - 6231
REVISIONS: DATE:
N
NO.
NOT TO SCALE
GI005
664-CSI-116
BLDG #1
QUALITY CONSTRUCTIONMICHAEL DEGNAN - VA DESIGN PROJECT MANAGER
www.coffman.com ph 619.232.4673
1455 Frazee Rd., Suite 600 San Diego, CA 92108 ph 619.232.46736/11/2019
7/16/2019 8/23/2019
12/24/2020
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN- RESUBMITTAL
65% DESIGN DEVELOPMENT
REVISED 65% DESIGN DEVELOPMENT
100% CONSTRUCTION DOCUMENTS
02/18/2021 95% CONSTRUCTION DOCUMENTS
04/09/2021 100% CONSTRUCTION DOCUMENTS
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
VA MEDICAL CENTER SAN DIEGO, 3350 LA JOLLA
VILLAGE DR., SAN DIEGO, CA 92161
MAY 10, 2021
REVIEWED IN
ACCORDANCE WITH THE
REQUIRMENTS OF CFM
BY:___________________
DATE:________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
05/10/2021 IFC DOCUMENTS 4TH FLOOR 4N CARDIOLOGY CATH LAB 2
FP 1842
EXP.6/30/2022
STAT E OF CA L I FORN I A
RE
G
I S
TE
RED PROFESS I ONAL ENG
I NEER
DEREK R. DUVAL