This is a technical proposal and product documentation package for the TIGERFLOW Standard Booster System, a variable-speed duplex pumping package designed for constant pressure water boosting applications.
The technical offer dated June 9, 2026, specifies a duplex booster system (Model TF-00-002) configured for 60 psi discharge pressure with 40 psi differential pressure and 80 US GPM flow at 208V/1Ф/60Hz. The mechanical scope includes two CDF15-2 centrifugal pumps rated at 5 HP (230/460V/3Ф/60Hz), grooved butterfly valves, wafer-style check valves, 304 stainless steel manifolds, flanges, and a thermal purge assembly option. The control system features a Tigerflow Mark V duplex controller with a 6-inch Schneider Human Machine Interface touchscreen, UL/C-UL 508 certification, ASHRAE 90.1 compliance, 10kA RMS short circuit rating, and comprehensive monitoring capabilities including PID tuning, pressure read-outs, event history logging, individual pump run indication, hand-off-automatic selectors, and multiple alarm functions. Communication capabilities include RS-232, RS-485, RS-422 ports, and options for BACnet IP/MS-TP or Modbus TCP/RTU protocols. Manufacturing requirements mandate ASME Section IX certified welders for pipe welding and AWS D1.1 certified welders for structural work. Deliverable documents include mechanical GA drawings, electrical schematics, installation and operations manuals, hydrostatic test reports, and run test reports. The system is ISO 9001 certified and includes a 24-month warranty against defects in material, design, and workmanship when installed and maintained per factory recommendations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| VA CBOC RFQ_May 2026.docx | DOCX document | |
| AS CBOC Plumbing Floor Plan.pdf | ||
| 36C26126R0044 0003.docx | DOCX document | |
| 36C26126R0044 0002.docx | DOCX document | |
| RFI.docx | DOCX document | |
| 36C26126R0044 0001.docx | DOCX document | |
| 01 32 16-15 Project Schedules.docx | DOCX document | |
| 01 35 26 Safety Requirements.docx | DOCX document | |
| 01 00 00 General Requirements.docx | DOCX document | |
| Statement of Work.docx | DOCX document | |
| 2026 04 20 - BiddingPurposes PCRA - AS CBOC Domestic Water Pump.pdf | ||
| Attachment REQUEST FOR INFORMATION FORM.docx | DOCX document | |
| Attachment Price Breakdown Improve Water Pressure.xlsx | XLSX spreadsheet | |
| Wage Determination American Samoa 01.02.2026.pdf | ||
| 36C26126R0044.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TIGERFLOW Systems, LLC 4034 Mint Way ◊ Dallas, TX 75237 ◊ (800) 783-6756 © 2025 TIGERFLOW
TIGERFLOW STANDARD BOOSTER SYSTEM PLUMBING
Technical Offer
4034 Mint Way Dallas Texas 75237
214.337.8780 sales@tigerflow.com
Job Information Date: 2026/6/9
Project Number: -1 Project Name:
Address:
Representative: e-mail:
Station Condition Point Discharge Pressure: 60 psi
Differential Pressure: 40 psi Suction Type: Boost
Suction Pressure: 20 psig Rated / 30 psig Max Station Flow: 80 us.gpm
Station Voltage: 208v/1Ф/60Hz Scope of Supply
QTY DESCRIPTION P/N
Mechanical Duplex Booster (TF-00-002)
(4) Grooved Style Butterfly Valves, 2"
(2) Wafer Style Check Valves, 2" -Suction and Discharge Manifolds, 304SS, 3"
3200000513
2 PUMP, TIGERFLOW, CDF15-2-C0GD2B, 184TC, 5HP, 230/460V/3Ф/60Hz, TEFC 3300002958
1 Assembly, Tank Feed, 3"x1-1/2" (A03-01) 3200000264
4 Flange FLGxWN, 304SS, CLASS 300, 2" 3200007698
Mechanical Options 1 Thermal Purge ASSEMBLY, THERMAL PURGE, DUPLEX TP-2
Controls 1 Controls, Tigerflow Mark V, Duplex, 5HP, 208V-230V/1Ф/60Hz 3300000033
Features:
-6" Schneider Human Machine Interface (HMI) -UL/C-UL 508 control panel -ASHRAE 90.1 compliant control algorithm -Short Circuit Currrrent Rating (SCCR) 10kA RMS at 600 VAC -Individual motor disconnects with fused circuit protection -Power On Light -Alarm Horn -Common auxiliary alarm contacts -Solid State Micro Controller:
-Non-volatile Memory - no battery backup required -Multi level security passwords -Tuning (PID) pressure sequencing with read-out in psi -Suction and discharge pressure read-out in psi -Event history log -Individual pump run indication -Hand-off-automatic selectors -Elapsed time meter -Low suction alarm with on-off time delays -Low system with on-off time delays -High suction “energy savings” shutdown with on-off time delays, enable /disable -High system alarm with on-off time delays -Automatic alternation of equal sized pumps -RS-232, RS-485, RS-422 communication ports
TIGERFLOW Systems LLC is an ISO 9001 certified company 1 of 2
Technical Offer
4034 Mint Way Dallas Texas 75237
214.337.8780 sales@tigerflow.com
Scope of Supply
QTY DESCRIPTION P/N
-Variable Frequency Drives (VFDs) with PWM and panel mounted operator interfaces
1 Transducer, 0-300 PSI 3200023032 BAS Communication Protocol: None
Manufacturing Requirments All pipe welding to be performmed by ASME Sectoin IX certified welders All structural welding to be performmed by AWS D1.1 certified welders
NOTES:
Documents Mechanical GA drawings Electrical schematics
IO&M
Hydrostatic test report Run test report
TIGERFLOW Systems LLC is an ISO 9001 certified company 2 of 2
TF-00-002 - VMS, 3" X 2", DUPLEX, 10-20/22 SM
QUANTITY: XX
DETAIL A
TRANSDUCER ASSEMBLY
TYP. SUCTION/DISCHARGE
320000477660PRESSURE TRANSDUCER, GEMS 3500
B300PG02E000, 0-300 PSI, 4-20MA OUTPUT,
1/4" NPT, 3M CABLE
3200010726711-00500025HEX BUSHING, ASTM A351 CF8(304), CLASS
150, 1/2"x1/4"
3200018802925-002500PLUG, MNPT, ASTM A351 CF8(304SS), CLASS
150, 1/4"
3200010613707-0005000TEE, NPT, ASTM A351 CF8 (304), CLASS 150,
1/2"
3200012081825-0792520VALVE, TEST COCK, WATTS LFTC, 1/2"289
3100000485774-00500250NIPPLE, 304SS, S40, 1/2x2 1/2"488
32000224953200022495VALVE, CHECK, TIGERFLOW 871W, 2"287
32000217133200021713VALVE, BUTTERFLY, TIGERFLOW N-GD-381L,
LEVER, 2"
3200011416787-P1064PLATE, UNISTRUT P1064, 1-5/8"X1-5/8X1/4",
Ø1/2"
321161000Z20001301-5/8"x1-5/8",12GA, PRE GAL, 9/16"x1-1/8"
SLOT
200TAPE, DIRECTIONAL, GREEN W/ WHITE
ARROWS
3100000734787-369646STRUT ACCESORIES, BASE CONNECTOR,
HILTI MQP-1/1
321161000Z20001301-5/8"x1-5/8",12GA, PRE GAL, 9/16"x1-1/8"
SLOT
3200019498150LEVELING MOUNT, 5000LB, GRAINGER
5VN02, 5/8"-11
3200018958200GASKET, NSF-61216
SEE BOM60FLGxWN, 304SS, CLASS XXX, 2"415
320001307760COUPLING, RIGID, ANVIL 7401, 3"214
3200013073836-0390013514COUPLING, ANVIL 7401, EDPM, 2"813
3200000264160CAP,304SS,3GRV,A02-07112
3200000246A01-00MBASE, FORMED, DUPLEX, ORANGE, A01-00M111
32000004853200000485PANEL STAND, INTERNAL DRIVE, VMS, PS001110
3200000496150PIPE SUPPORT29
3200000693W01-02MANIFOLD, 3x2, DUPLEX, 304SS, 20", VMS28
SEE E-BOMSEE E-BOMCONTROLLER, TIGERFLOW MARK V,
INTERNAL DRIVES
PUMPPUMP_TIGERFL
OW_CD20-10
SEE CHART 121
PARTS LIST
SAP PNP/NDESCRIPTIONQTYSYM
3200004776PRESSURE TRANSDUCER, GEMS 3500 B300PG02E000, 0-300 PSI, 4-20MA
OUTPUT, 1/4" NPT, 3M CABLE
3200010726HEX BUSHING, ASTM A351 CF8(304), CLASS 150, 1/2"x1/4"492
3200018802PLUG, MNPT, ASTM A351 CF8(304SS), CLASS 150, 1/4"291
3200010613TEE, NPT, ASTM A351 CF8 (304), CLASS 150, 1/2"290
3200012081VALVE, TEST COCK, WATTS LFTC, 1/2"289
3100000485NIPPLE, 304SS, S40, 1/2x2 1/2"488
3200022495VALVE, CHECK, TIGERFLOW 871W, 2"287
3200021713VALVE, BUTTERFLY, TIGERFLOW N-GD-381L, LEVER, 2"486
3200011416PLATE, UNISTRUT P1064, 1-5/8"X1-5/8X1/4", Ø1/2"485
3211610001-5/8"x1-5/8",12GA, PRE GAL, 9/16"x1-1/8" SLOT284
3100000734STRUT ACCESORIES, BASE CONNECTOR, HILTI MQP-1/1222
3211610001-5/8"x1-5/8",12GA, PRE GAL, 9/16"x1-1/8" SLOT121
3200019498LEVELING MOUNT, 5000LB, GRAINGER 5VN02, 5/8"-11218
3200018958GASKET, NSF-61216
SEE BOMFLGxWN, 304SS, CLASS XXX, 2"415
3200013077COUPLING, RIGID, ANVIL 7401, 3"214
3200013073COUPLING, ANVIL 7401, EDPM, 2"813
3200000264CAP,304SS,3GRV,A02-07112
3200000246BASE, FORMED, DUPLEX, ORANGE, A01-00M111
3200000485PANEL STAND, INTERNAL DRIVE, VMS, PS001110
3200000496PIPE SUPPORT29
3200000693MANIFOLD, 3x2, DUPLEX, 304SS, 20", VMS28
SEE E-BOMCONTROLLER, TIGERFLOW MARK V, INTERNAL DRIVES15
PUMPSEE CHART 121
PARTS LIST
SAP PNDESCRIPTIONQTYSYM
A
\\DC01\Departments\Special Projects\R2014-001 Standard Booster\Standard Booster\VMS-4000\CAD Parts\Assy Standard\TF-00-002 - Booster VMS 10-20_22 SM Duplex\TF-00-002.idw
P1 P2
4034 MINT WAY
DALLAS, TX 75237
PHONE: 214.337.8780
WWW.TIGERFLOW.COM
DATE
DATE
ENGR
CHK
PART NUMBER / SAP NUMBER REV
THIS DOCUMENT CONTAINS INFORMATION
THAT IS CONFIDENTIAL AND PROPRIETARY
TO TIGERFLOW SYSTEMS, LLC.
("TIGERFLOW"). THIS DOCUMENT IS
FURNISHED WITH THE UNDERSTANDING
THAT THE DOCUMENT AND THE
INFORMATION IT CONTAINS WILL NOT BE
COPIED OR DISCLOSED TO OTHERS
EXCEPT WITH THE WRITTEN CONSENT OF
TIGERFLOW, WILL NOT BE USED EXCEPT
FOR THE BENEFIT OF TIGERFLOW AND
WILL BE RETURNED AND ALL FURTHER
USE DISCONTINUED UPON REQUEST FROM
TIGERFLOW.
1. DIMENSIONING PER ASME Y14.5-2009.
2. DO NOT SCALE DRAWING.
3. DO NOT USE FOR CONSTRUCTION
PURPOSES UNLESS CERTIFIED.
4. DIMENSIONS ARE IN INCHES
M. MARTINEZ 4/27/2017
B. ANTAL 8/1/2018
TF-00-002 / 3200000513
VMS, 3" X 2", DUPLEX, 10-20/22 SM
1 /1
DESCRIPTION
PAGE
TIGERFLOW®
1/4"
.X .1
.XX .05
(XX) INDICATES REFERENCE,
NON-TOLERANCED DIMENSIONS
FRACTIONAL
DECIMAL
BIGGEST PUMP SIZE SUPPORTED - CHART 1
BRAND MODEL STAGES HP
TIGERFLOW CDF 10 17 15
TIGERFLOW CDF 15 12 25
TIGERFLOW CDF 20 10 25
Goulds 10SV 12 10
Goulds 15SV 10 20
Goulds 22SV 10 25
Ebara EVM 10 12 10
Ebara EVM 18 8 20
Grundfos CR 10 12 10
Grundfos CR 15 10 20
Grundfos CR 20 8 20
NOTES:
1. MAXIMUM WORKING PRESSURE: 250 PSI (PUMPS WITH CLASS 150
FLANGES), 300 PSI (PUMPS WITH CLASS 300 FLANGES)
2. MAX WEIGHT: 871 LBS
3. ALL PIPE WELDING SHALL BE PERFORMED BY ASME SECTION 9
QUALIFIED WELDERS; ALL STRUCTURAL WELDING SHALL BE
PERFORMED BY AWS D1.1 QUALIFIED WELDERS.
4. 48" CLEARANCE (CLEAR TO GROUND) REQUIRED IN FRONT OF
CONTROL PANELS PER 2011 NEC TABLE 110-26(A)(1) CONDITION 3;
USER ASSUMES ALL RESPONSIBILITY FOR EVALUATION OF SITE
CONDITIONS AND NEC CODE COMPLIANCE IF INSTALLING PER
CONDITION 1 OR 2 CLEARANCES.
5. MANIFOLDS GROOVED BOTH END TO ALLOW FOR CONNECTION AT
EITHER END.
6. APPROXIMATE WIDTH WITH DISCHARGE MANIFOLD REMOVED.
7. PRESSURE TRANSDUCER WILL BE PROVIDED FOR BOOST
APPLICATIONS; LOOP SWITCH WILL BE PROVIDED FOR FLODDED
APPLICATIONS. REFER TO WORK ORDER FOR OPTION.
8. TANK FEED IS SUPPLIED BY DEFAULT WHEN AN ADJACENT
MOUNTED TANK IS ORDERED OR WHEN EXPLICITLY ORDERED. SEE
WORK ORDER OR PURCHASE TO CONFIRM.
9. SEE WORK ORDER FOR PAINT COLOR.
NOTES:
1. 48" CLEARANCE (CLEAR TO GROUND) REQUIRED IN FRONT OF CONTROL
PANELS PER 2011 NEC TABLE 110-26(A)(1) CONDITION 3; USER ASSUMES
ALL RESPONSIBILITY FOR EVALUATION OF SITE CONDITIONS AND NEC
CODE COMPLIANCE IF INSTALLING PER CONDITION 1 OR 2 CLEARANCES.
2. 30" CLEARANCE OR PANEL WIDTH MINIMUM REQUIRED FOR NEC
CLEARNACE.
3. UNLESS OTHERWISE INDICATED, ALLOW 12" CLEARANCE AROUND SYSTEM
FOR SERVICE.
4. ALL PIPE WELDING TO BE PERFORMED BY ASME SECTION IX CERTIFIED
WELDERS.
5. ALL STRUCTURAL WELDING TO BE PERFORMED BY AWS D1.1 CERTIFIED
WELDERS.
6. PRESSURE TRANSDUCER WILL BE PROVIDED FOR BOOST APPLICATIONS;
LOP SWITCH WILL BE PROVIDED FOR FLOODED APPLICATIONS. REFER TO
WORK ORDER FOR OPTION.
7. CONNECTION CENTERLINE DIMENSIONS ARE REFERENCE ONLY. AS-BUILT
MEASUREMENTS TO BE PROVIDED PRIOR TO SHIPMENT OF STATION UPON
REQUEST.
8. TANK FEED IS SUPPLIED WHEN EXPLICITLY ORDERED. SEE WORK ORDER
OR PURCHASE TO CONFIRM.
9. HYDROSTATIC TEST TO 250 PSI FOR 15 MINUTES. SEE WORK ORDER OR
PURCHASE TO CONFIRM.
10. SEE WORK ORDER FOR STANDARD PERFORMANCE TEST OR X-Y
PERFORMANCE TEST.
11. MAX. SHIPPING WEIGHT: 580 LBS.
12. SEE WORK ORDER FOR PAINT COLOR.
13. SEE WORK ORDER FOR THERMAL PURGE OPTION.
14. MANIFOLD GROOVED BOTH END FOR CONNECTION AT EITHER END.
15. APPROXIMATE WIDTH WITH DISCHARGE MANIFOLD REMOVED.
REV DESCRIPTION DATE APPROVED
PAGE(S)
1 UPDATE BILL AND HEADERS. 8/1/2018 B. ANTAL
CHANGED BUTTERFLY AND CHECK
VALVES
5/12/2020 A. LUCIANO
(33)(6) (1)
(19)
(40)
(47 3/4)
TANK FEED LENGTH
(36 3/4)
(20 1/2)
(46 3/4)
(61 1/4)
1 1/2" FNPT TANK
CONNECTION
SEE NOTE 8
SEE NOTE 1 & 2
BOLT-ON
PANEL STAND
3" GROOVED
DISCHARGE
CONNECTION
3" GROOVED
SUCTION
CONNECTION
(7)
(34 1/2)
SEE NOTE 15
X4 5/8
TigerFlow Pump Quotation System 23.2.0
0 15 30 45 60 75 90 105 120 Flow(us.gpm)
1.5
2.5
3.5
Po w er (H
P)
He ad
(F t)
100 Efficiency (%
N
PS
H( ft
Speed: 3500 rpmMCSF
Pump Performance Curve
Representative : Size : CD15-2 System flowrate : 80 US.gpm Customer : Stages : 2 Differential head / pressure, rated (requested) : 99.24 ft Item number : Speed, rated : 3500 rpm Differential head / pressure, rated (actual) : 107.28 ft Service : Based on curve number : CD15-2 Fluid density, rated / max : 1.00 / 1.00 SG Quantity : 1 Efficiency : 70% Viscosity : 1 cP Project number : Power, rated, maximum : 3.2 / 3.5 hp Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1 / 1 / 1 / 1 Date last saved : 2026/6/9 NPSH required : 6.3 ft
TIGERFLOW Systems, LLC. · 4034 Mint Way · Dallas, TX 75237 phone: (214) 337-8780
VIEW A-A
A A
D:\INVENTOR\CD_Catalog\CD_PUMPS\PUMP_TIGERFLOW_CD10_CATALOG.idw
4034 MINT WAY
DALLAS, TX 75237
PHONE: 214.337.8780
WWW.TIGERFLOW.COM
THIS DOCUMENT CONTAINS INFORMATION
THAT IS CONFIDENTIAL AND PROPRIETARY
TO TIGERFLOW SYSTEMS, LLC.
("TIGERFLOW"). THIS DOCUMENT IS
FURNISHED WITH THE UNDERSTANDING
THAT THE DOCUMENT AND THE
INFORMATION IT CONTAINS WILL NOT BE
COPIED OR DISCLOSED TO OTHERS
EXCEPT WITH THE WRITTEN CONSENT OF
TIGERFLOW, WILL NOT BE USED EXCEPT
FOR THE BENEFIT OF TIGERFLOW AND
WILL BE RETURNED AND ALL FURTHER
USE DISCONTINUED UPON REQUEST FROM
TIGERFLOW.
1. DIMENSIONING PER ASME Y14.5-2009.
2. DO NOT SCALE DRAWING.
3. DO NOT USE FOR CONSTRUCTION
PURPOSES UNLESS CERTIFIED.
4. DIMENSIONS ARE IN INCHES
TIGERFLOW®
`1/4"
.X `.1
.XX `.05
(XX) INDICATES REFERENCE,
NON-TOLERANCED DIMENSIONS
FRACTIONAL
DECIMAL
5.12
[130]
7.56
[192]
11.42
[290]
8.74
[222] n.55
[n14]
L1
L2
11.81
[300]
3.54
[90]
BSP G1/2"
FILL/VENT
BSP G1/2"
DRAIN
M1 REF
2"
CLASS 300
MOTOR CAN BE
ROTATED IN 90°
INCREMENTS
in[mm]
MODEL HP ENCLOSURE
L1 (IN) L2 (IN) D (IN) M1 (IN) M2 (IN) WEIGHT (LBS)
nD REF
D
D
M:\Inventor\_ASSEMBLIES\THERMAL PURGE\THERMAL_PURGE_DUPLEX\THERMAL_PURGE_DUPLEX.idw
3100000461NIPPLE, ASTM A312 TP304/L, S40, 1/4"x1"410 3100000482NIPPLE, ASTM A312 TP304/L, S40, 1/2"x2"29
3200010611TEE, NPT, ASTM A351 CF8(304), CLASS 150, 1/4"28
3200010613TEE, NPT, ASTM A351 CF8(304), CLASS 150, 1/2"27
3200010726HEX BUSHING, ASTM A351 CF8(304), CLASS 150, 1/2"x1/4"26 3200018693ADAPTER, STRAIGHT, COMPRESSION x NPT, BRASS, 1/4"45 3100000127TUBING, 316SS, 0.25"ODx.035"WALL14 3100000127TUBING, 316SS, 0.25"ODx.035"WALL13
3200018898VALVE, THERMAL PURGE, ECONO/HAT-RA M/ F S/S, 1/4"12
3200022875VALVE, BALL, TIGERFLOW, 8081-10-T, 1/4"21
PARTS LIST
SAP PNDESCRIPTIONQTYSYM
4034 MINT WAY
DALLAS, TX 75237
PHONE: 214.337.8780
WWW.TIGERFLOW.COM
DATE
DATE
ENGR
CHK
PART NUMBER / SAP NUMBER REV
THIS DOCUMENT CONTAINS INFORMATION
THAT IS CONFIDENTIAL AND PROPRIETARY
TO TIGERFLOW SYSTEMS, LLC.
("TIGERFLOW"). THIS DOCUMENT IS
FURNISHED WITH THE UNDERSTANDING
THAT THE DOCUMENT AND THE
INFORMATION IT CONTAINS WILL NOT BE
COPIED OR DISCLOSED TO OTHERS
EXCEPT WITH THE WRITTEN CONSENT OF
TIGERFLOW, WILL NOT BE USED EXCEPT
FOR THE BENEFIT OF TIGERFLOW AND
WILL BE RETURNED AND ALL FURTHER
USE DISCONTINUED UPON REQUEST FROM
TIGERFLOW.
1. DIMENSIONING PER ASME Y14.5-2009.
2. DO NOT SCALE DRAWING.
3. DO NOT USE FOR CONSTRUCTION
PURPOSES UNLESS CERTIFIED.
4. DIMENSIONS ARE IN INCHES
M. MARTINEZ 3/8/2023
j. YAMASHITA 3/8/2023
A05-01 / 3200026683
ASSY, THERMAL PURGE, DUPLEX
(A05-01)
1 /1
DESCRIPTION
PAGE
TIGERFLOW®
1/4" .X .1
.XX .05
(XX) INDICATES REFERENCE,
NON-TOLERANCED DIMENSIONS
FRACTIONAL
DECIMAL
VENT PLUG FROM PUMP (VMS SYSTEMS) OR
PLUG FROM DISCHARGE SPOOL (ES SYSTEMS)
1/4" FNPT PIPED TO
DRAIN BY OTHERS
SUCTION
MANIFOLD
ECONOHATRA
Rev: 5/24/17
1-877-379-8258 | www.ThermOmegaTech.com
ISO9001
CERTIFIED
ECONO/HAT-RA
PUMP THERMAL RELIEF VALVE
OPERATION
As the fluid temperature increases to within the operating range of the ECONO/HAT-RA, the thermal actuator modulates the valve open. If the fluid temperature is above the acceptable range, the valve will continue to modulate open allowing additional fluid discharge. As the outlet temperature falls slightly, the valve then modulates toward the closed position, reducing flow. This modulating action maintains a relatively constant fluid temperature even as operating conditions vary.
•• Protects pump and pump seals from over-temperature damage
•• Prevents potentially scalding water from being distributed to users
•• Totally self-operating, no power or signal required •• Completely mechanical thermal relief for booster pumps and cooling jackets.
•• Temperature response is unaffected by pressure variations •• Wrench flats for easy installation
•• Compact, low mass •• Corrosion resistant, long service life •• Ram-type plug for tight, reliable shutoff •• Narrow temperature band
The ECONO/HAT-RA valve is perfect for thermal relief of booster pumps; controlling cooling water outlet temperature; and controlling flow of cooling water, glycol or other cooling media in applications requiring economical removal of heat from equipment or a process. Since the ECONO/HAT-RA valves open on rising temperatures, they can be used in many other thermal relief valve applications.
BENEFITS
DESIGN FEATURES
APPLICATIONS
Because of continuous improvements, Therm-Omega-Tech, Inc. reserves the right to change the design and specifications without notice
ISO9001
CERTIFIED
Therm-Omega-Tech, Inc.
353 Ivyland Road 1-877-379-8258 Warminster, PA 18974 www.ThermOmegaTech.com
MADE IN
THE USA
ECONOHATRA
Rev: 5/24/17
ECONO/HAT-RA
PUMP THERMAL RELIEF VALVE
ITEM DESCRIPTION MATERIAL
1 VALVE BODY Brass or 300 Series SS
2 THERMAL ACTUATOR Brass or 300 Series SS
3 OPERATING SPRING 300 Series SS
4 RAM-TYPE PLUG 300 Series SS
5 SEAT FITTING Brass or 300 Series SS
6 SEAT SEAL PTFE
7 BODY SEAL BUNA (NSF-61 Certified)
8 CALIBRATION LOCKNUT 300 Series SS
9 SEAT RETAINER Brass or 300 Series SS
10 SEAT INSERT Brass or 300 Series SS
ORDERING
NOTES
SIZE
(NPT)
D L Weight
CV
Maximum Operating Pressure
Maximum Temperaturein mm in mm Lb Kg
1/4” Brass
1.0 25 3.6 89 0.4 0.2 0.5
300 PSIG
(20.7 BAR) 250°F
(121°C)
1/4” SS 400 PSIG
(27.6 BAR)
Part Number Description
242 - 000000 - XXX 1/4” ECONO/HAT-RA M/F
242 - 010000 - XXX 1/4” ECONO/HAT-RA M/F SS
1. Full open temperatures “XXX” available: 040°F, 045°F, 050°F, 060°F, 070°F, 075°F, 085°F, 095°F, 100°F, 105°F, 110°F, 115°F, 120°F, 125°F, 130°F, 140°F, 150°F, 160°F, 170°F, 175°F, 180°F, 190°F, 200°F and 210°F.
| a. | Note: Closing temperature is typically 10°F below opening temperature. |
| 2. | A #20 mesh strainer is recommended. |
| 3. | Warranty information disclosed at www.thermomegatech.com/terms-conditions/ |
PARTS & MATERIALS
DIMENSIONS & CAPACITIES
L
D
1 2 8 463 7 5
FLOW
9 10 chaz.ward Rectangle chaz.ward Rectangle chaz.ward Rectangle
MA (Hp)
Motor
FLA
(Amps)
D2
(Amps)
WC
(AWG)
FC
(Amps)
CA
1 4.6/4.2 40 12 20 1/2"
1.5 6.6/6 40 12 20 1/2"
2 7.5/6.8 40 10 30 1/2"
3 10.6/9.6 40 10 30 1/2"
5 16.7/15.2 80 6 60 3/4"
MA (Hp)
System FLA
(Amps) WA (AWG) MA (Hp)
System FLA
(Amps) WA (AWG)
2 Pumps 3 Pumps
1 33 10 1 46.8 8
1.5 33 10 1.5 46.8 8
2 47.5 8 2 67.6 4
3 56 6 3 80 4
5 80.75 4 5 115 2
VOLTS F11 F12
208 2 AMP 2 AMP
230 2 AMP 2 AMP
XXX XX X
THE INFORMATION, DATA AND DESIGN CONTAINED IN THIS
DRAWING ARE CONFIDENTIAL AND PROPRIETARY INFORMATION
TO TIGERFLOW SYSTEMS LLC DISCLOSURE OR USE WITHOUT THE
WRITTEN PERMISSION OF TIGERFLOW SYSTEMS LLC IS
PROHIBITED.
TIGERFLOW®
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
4034 MINT WAY
AutoCAD SHX Text
CONTROLS SCHEMATIC
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
DGN BY:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
4034 MINT WAY
AutoCAD SHX Text
DALLAS, TEXAS 75237
AutoCAD SHX Text 214-337-8780
AutoCAD SHX Text 800-783-6756
AutoCAD SHX Text www.tigerflow.com
AutoCAD SHX Text engineering@tigerflow.com
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
JOB#:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
AutoCAD SHX Text
MARK V - BOOSTER SYSTEM
AutoCAD SHX Text THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO TIGERFLOW SYSTEMS, LLC. ("TIGERFLOW"). THIS DOCUMENT IS FURNISHED WITH THE UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT OF TIGERFLOW, WILL NOT BE USED EXCEPT FOR THE BENEFIT OF TIGERFLOW AND WILL BE RETURNED AND ALL FURTHER USE DISCONTINUED UPON REQUEST FROM TIGERFLOW.
AutoCAD SHX Text
6" HMI
AutoCAD SHX Text
ETH TCP/IP
AutoCAD SHX Text
RS-485 SER COM1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
USB PGM PORT
AutoCAD SHX Text
RJ45 ADAPTER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CAT 5 CABLE
AutoCAD SHX Text
TO PLC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSTRUMENTATION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D IN 1
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
A IN 1
AutoCAD SHX Text
REL1 COM
AutoCAD SHX Text
REL1 NO
AutoCAD SHX Text
REL1 NC
AutoCAD SHX Text
VFD 1 TERMINALS
AutoCAD SHX Text
VFD 2 TERMINALS
AutoCAD SHX Text
VFD 3 TERMINALS
AutoCAD SHX Text 0V
AutoCAD SHX Text 24V+
AutoCAD SHX Text
PUR
AutoCAD SHX Text
BLK
AutoCAD SHX Text 4-20 mA +
AutoCAD SHX Text 4-20 mA -
AutoCAD SHX Text
DATA INDUSTRIAL FM-1
AutoCAD SHX Text Model 310
AutoCAD SHX Text D.I. Flow Meter
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text P/W
AutoCAD SHX Text
WHT
AutoCAD SHX Text
BLK
AutoCAD SHX Text DISCHARGE PRESSURE PT-1 4-20 mA 0-250 PSI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SUCTION PRESSURE PT-2 4-20 mA 0-250 PSI
AutoCAD SHX Text FLOW METER FM-1 4-20 mA
AutoCAD SHX Text
BRN
AutoCAD SHX Text
BLU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BRN
AutoCAD SHX Text
BLU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RED
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHD
AutoCAD SHX Text
BLK
AutoCAD SHX Text
SHLD
AutoCAD SHX Text
SIGN -
AutoCAD SHX Text
BLK
AutoCAD SHX Text
SHLD
AutoCAD SHX Text
SIGN -
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RED
AutoCAD SHX Text
SIGN +
AutoCAD SHX Text
RED
AutoCAD SHX Text
SIGN +
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VFD 4 TERMINALS
AutoCAD SHX Text
BRN
AutoCAD SHX Text
BRN
AutoCAD SHX Text
BLU
AutoCAD SHX Text
BLU
AutoCAD SHX Text
RED
AutoCAD SHX Text
BLU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 0V
AutoCAD SHX Text 24V+
AutoCAD SHX Text
CN7
AutoCAD SHX Text
CN8
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
DO7
AutoCAD SHX Text
DO6
AutoCAD SHX Text
DO5
AutoCAD SHX Text C567
AutoCAD SHX Text H1
AutoCAD SHX Text
DO3
AutoCAD SHX Text
DO4
AutoCAD SHX Text C34
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUMP 3 RUN RELAY
AutoCAD SHX Text
PUMP 4 RUN RELAY
AutoCAD SHX Text
COMMON 3/4
AutoCAD SHX Text
COMMON 1
AutoCAD SHX Text
PUMP 2 RUN RELAY
AutoCAD SHX Text
PUMP 1 RUN RELAY
AutoCAD SHX Text
24 VDC +
AutoCAD SHX Text
24 VDC -
AutoCAD SHX Text
ALARM HORN
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
COMMON 5/6/7
AutoCAD SHX Text
DI8
AutoCAD SHX Text
CN4
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
CN5
AutoCAD SHX Text
DI3
AutoCAD SHX Text
DI4
AutoCAD SHX Text
DI5
AutoCAD SHX Text
DI6
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
5 VDC AI POWER
AutoCAD SHX Text
24 VDC AI POWER
AutoCAD SHX Text
AI SPARE
AutoCAD SHX Text DISCHARGE PRESSURE TRANSDUCER (4-20 Ma)
AutoCAD SHX Text SUCTION PRESSURE TRANSDUCER (4-20 Ma)
AutoCAD SHX Text
PUMP 4 RUNNING FEEDBACK
AutoCAD SHX Text
PUMP 3 RUNNING FEEDBACK
AutoCAD SHX Text
SYSTEM DISABLE
AutoCAD SHX Text
PHASE MONITOR
AutoCAD SHX Text
LEVEL SWITCH
AutoCAD SHX Text
AI1
AutoCAD SHX Text
AI2
AutoCAD SHX Text
AI3
AutoCAD SHX Text
AI4
AutoCAD SHX Text
AI5
AutoCAD SHX Text
AI6
AutoCAD SHX Text
AI7
AutoCAD SHX Text
AI8
AutoCAD SHX Text
GND
AutoCAD SHX Text 5V
AutoCAD SHX Text 24V
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text FLOW METER SIGNAL (4-20 Ma)
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
DI7
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DI1
AutoCAD SHX Text
CN3
AutoCAD SHX Text
DI2
AutoCAD SHX Text
PUMP 2 RUNNING FEEDBACK
AutoCAD SHX Text
PUMP 1 RUNNING FEEDBACK
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AI SPARE
AutoCAD SHX Text
AI SPARE
AutoCAD SHX Text
AI SPARE
AutoCAD SHX Text
AI SPARE
AutoCAD SHX Text
CN2
AutoCAD SHX Text
AO1
AutoCAD SHX Text
AO2
AutoCAD SHX Text
AO3
AutoCAD SHX Text
AO4
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
RJ45 ADAPTER
AutoCAD SHX Text
M172P BOTTOM
AutoCAD SHX Text
M172P TOP
AutoCAD SHX Text D08+
AutoCAD SHX Text
CN6
AutoCAD SHX Text D08-
AutoCAD SHX Text C8
AutoCAD SHX Text
GENERAL ALARM N.O.
AutoCAD SHX Text
GENERAL ALARM N.C.
AutoCAD SHX Text
COMMON 8
AutoCAD SHX Text
CN9
AutoCAD SHX Text
DO1
AutoCAD SHX Text
DO2
AutoCAD SHX Text C1
AutoCAD SHX Text
CN10
AutoCAD SHX Text
VFD 1 SPEED REFERENCE
AutoCAD SHX Text
VFD 2 SPEED REFERENCE
AutoCAD SHX Text
VFD 4 SPEED REFERENCE
AutoCAD SHX Text
VFD 3 SPEED REFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
CN19
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
RS-485-1 (-)
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
RS-485-1 (+)
AutoCAD SHX Text
AutoCAD SHX Text
YEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
YEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
YEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D IN 1
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
A IN 1
AutoCAD SHX Text
REL1 COM
AutoCAD SHX Text
REL1 NO
AutoCAD SHX Text
REL1 NC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text P/W
AutoCAD SHX Text
WHT
AutoCAD SHX Text
BLK
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D IN 1
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
A IN 1
AutoCAD SHX Text
REL1 COM
AutoCAD SHX Text
REL1 NO
AutoCAD SHX Text
REL1 NC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text P/W
AutoCAD SHX Text
WHT
AutoCAD SHX Text
BLK
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D IN 1
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
A IN 1
AutoCAD SHX Text
REL1 COM
AutoCAD SHX Text
REL1 NO
AutoCAD SHX Text
REL1 NC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text P/W
AutoCAD SHX Text
WHT
AutoCAD SHX Text
BLK
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
PUR
AutoCAD SHX Text
AutoCAD SHX Text
CN1
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
RS-485-2 (-)
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
RS-485-2 (+)
AutoCAD SHX Text D+
AutoCAD SHX Text D-
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLK
AutoCAD SHX Text
AutoCAD SHX Text
WHT
AutoCAD SHX Text
AutoCAD SHX Text
TO HMI
AutoCAD SHX Text 12/10/2018
AutoCAD SHX Text
DVP
AutoCAD SHX Text 1.0
AutoCAD SHX Text
PT
AutoCAD SHX Text 12/10/2018
AutoCAD SHX Text
TF-ESC-007
AutoCAD SHX Text 03/26/2019
AutoCAD SHX Text
AutoCAD SHX Text
YEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
YEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
YEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
CN20
AutoCAD SHX Text
ETHERNET CONTROL
AutoCAD SHX Text
BACNET IP
AutoCAD SHX Text
AutoCAD SHX Text
PUR
AutoCAD SHX Text
COMMON 2
AutoCAD SHX Text C2
AutoCAD SHX Text
MODBUS IP
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
WHT
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
COM
AutoCAD SHX Text
DIG. OUTPUTS COMMON
AutoCAD SHX Text P/W
AutoCAD SHX Text
COM
AutoCAD SHX Text
DIG. OUTPUTS COMMON
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L1
AutoCAD SHX Text
AutoCAD SHX Text P/W
AutoCAD SHX Text
AutoCAD SHX Text
PUR
CONTROL POWER LIGHT
WIRE # SIZE TYPE COLOR TERM.
REQ.
TERM.
TYPE
101 14 AWG THHN RED - SCREW
102 14 AWG THHN RED 3 SCREW
103 14 AWG THHN BLK - SCREW
104 14 AWG THHN BLK - SCREW
130 16 AWG THHN YEL 1 SCREW
131 16 AWG THHN YEL 1 SCREW
132 16 AWG THHN YEL 1 SCREW
133 16 AWG THHN YEL 1 SCREW
200 14 AWG THHN WHT 3 SCREW
203 18 AWG THHN BLK 1 SCREW
204 18 AWG THHN BLK 1 SCREW
207 18 AWG THHN BLK 1 SCREW
WIRE # SIZE TYPE COLOR TERM.
REQ.
TERM.
TYPE
209 18 AWG THHN BLK 1 SCREW
210 18 AWG THHN RED 1 SCREW
251 18 AWG THHN BLK 1 SCREW
252 18 AWG THHN BLK 1 SCREW
253 18 AWG THHN BLK 1 SCREW
254 18 AWG THHN BLK 1 SCREW
ACOM 18 AWG THHN WHT 2 SCREW
290(A) D+ 18 AWG TWS PAIR BLK 1 SCREW
290(B) D- 18 AWG TWS PAIR WHT 1 SCREW
400 18 AWG THHN PUR/WHT 4 SCREW
401 18 AWG THHN PUR - SCREW
402 18 AWG THHN PUR 6 SCREW
WIRE # SIZE TYPE COLOR TERM.
REQ.
TERM.
TYPE
409 18 AWG THHN PUR - SCREW
411 18 AWG THHN PUR - SCREW
412 18 AWG THHN PUR 3 SCREW
413 18 AWG THHN PUR - SCREW
415 18 AWG THHN PUR - SCREW
420 18 AWG THHN PUR - SCREW
421 18 AWG THHN PUR - SCREW
422 18 AWG THHN PUR - SCREW
423 18 AWG THHN PUR - SCREW
424 18 AWG THHN PUR - SCREW
425 18 AWG THHN PUR 1 SCREW
426 18 AWG THHN PUR 1 SCREW
TIGERFLOW®
WIRE # SIZE TYPE COLOR TERM.
REQ. TERM. TYPE
427 18 AWG THHN PUR 1 SCREW
428 18 AWG THHN PUR 1 SCREW
920 18 AWG THHN YEL 1 SCREW
921 18 AWG THHN YEL 1 SCREW
922 18 AWG THHN YEL 1 SCREW
GND 18 AWG THHN GRN 6 SCREW
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
4034 MINT WAY
AutoCAD SHX Text
CONTROLS SCHEMATIC
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
DGN BY:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
4034 MINT WAY
AutoCAD SHX Text
DALLAS, TEXAS 75237
AutoCAD SHX Text 214-337-8780
AutoCAD SHX Text 800-783-6756
AutoCAD SHX Text www.tigerflow.com
AutoCAD SHX Text engineering@tigerflow.com
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
JOB#:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
AutoCAD SHX Text
MARK V - BOOSTER SYSTEM
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
GND
AutoCAD SHX Text R
AutoCAD SHX Text A2
AutoCAD SHX Text A1
AutoCAD SHX Text H1
AutoCAD SHX Text L
AutoCAD SHX Text H1
AutoCAD SHX Text
XF
AutoCAD SHX Text X2
AutoCAD SHX Text X1
AutoCAD SHX Text M
AutoCAD SHX Text
CB
AutoCAD SHX Text F
AutoCAD SHX Text H4
AutoCAD SHX Text H2
AutoCAD SHX Text H3
AutoCAD SHX Text
CF
AutoCAD SHX Text
RESISTOR
AutoCAD SHX Text
CAPACITOR
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
FLOAT SWITCH
AutoCAD SHX Text
INDICATING LIGHT
AutoCAD SHX Text
RELAY
AutoCAD SHX Text
AUDIBLE HORN
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
CIRCUIT BREAKER
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
DISCONNECT SWITCH
AutoCAD SHX Text
COOLING FAN
AutoCAD SHX Text
CONNECTION POINT
AutoCAD SHX Text
PLC TERMINAL
AutoCAD SHX Text
PANEL TERMINAL
AutoCAD SHX Text
VFD TERMINAL
AutoCAD SHX Text
TERMINAL BLOCK 1
AutoCAD SHX Text
TWISTED PAIR
AutoCAD SHX Text
SHIELDED CABLE
AutoCAD SHX Text
CONTROP PANEL
AutoCAD SHX Text
WIRE
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
FIELD WIRE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24+ VDC
AutoCAD SHX Text
24+ VDC
AutoCAD SHX Text
24+ VDC
AutoCAD SHX Text
24+ VDC
AutoCAD SHX Text
0 VDC
AutoCAD SHX Text
0 VDC
AutoCAD SHX Text DISCHARGE PT A IN (4-20 mA)
AutoCAD SHX Text SUCTION PT A IN (4-20 mA)
AutoCAD SHX Text
SYSTEM DISABLE D IN
AutoCAD SHX Text
PHASE MONITOR D IN
AutoCAD SHX Text
FLOW SWITCH D IN
AutoCAD SHX Text
LEVEL SWITCH D IN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24+ ANALOG INPUT VDC
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
GND
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
24+ VDC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
0 VDC
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
120 VAC
AutoCAD SHX Text
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
GROUND
AutoCAD SHX Text D+
AutoCAD SHX Text D-
AutoCAD SHX Text
BMS MODBUS/BACNET COMM. D+
AutoCAD SHX Text
BMS MODBUS/BACNET COMM. D-
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D+
AutoCAD SHX Text D-
AutoCAD SHX Text
AutoCAD SHX Text
120 VAC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
120 VAC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL ALARM CONTACT (N.C.)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL ALARM CONTACT (N.0.)
AutoCAD SHX Text
GENERAL ALARM COMMON CONTACT
AutoCAD SHX Text
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24+ ANALOG INPUT VDC
AutoCAD SHX Text
D.I. F.M. PULSE SIGNAL -
AutoCAD SHX Text FLOW METER A IN (4-20 mA)
AutoCAD SHX Text
D.I. F.M. PULSE SIGNAL +
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CUSTOMER TERMNIALS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VFD 1 SPEED REFERECE
AutoCAD SHX Text
AutoCAD SHX Text
VFD 2 SPEED REFERENCE
AutoCAD SHX Text
VFD 3 SPEED REFERENCE
AutoCAD SHX Text
VFD 4 SPEED REFERENCE
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
AutoCAD SHX Text
24+ ANALOG INPUT VDC
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
24+ VDC
AutoCAD SHX Text
AutoCAD SHX Text 12/10/2018
AutoCAD SHX Text
DVP
AutoCAD SHX Text 1.0
AutoCAD SHX Text
PT
AutoCAD SHX Text 12/10/2018
AutoCAD SHX Text
TF-ESC-007
AutoCAD SHX Text 03/26/2019
AutoCAD SHX Text THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO TIGERFLOW SYSTEMS, LLC. ("TIGERFLOW"). THIS DOCUMENT IS FURNISHED WITH THE UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT OF TIGERFLOW, WILL NOT BE USED EXCEPT FOR THE BENEFIT OF TIGERFLOW AND WILL BE RETURNED AND ALL FURTHER USE DISCONTINUED UPON REQUEST FROM TIGERFLOW.
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
GND
AutoCAD SHX Text
ACOM
AutoCAD SHX Text
ACOM
ACOM
TIGERFLOW MARK V
Control Panel Manual
With Schneider M172P PLC & Magelis HMI
Built-in BACnet IP, Modbus TCP/IP and BACnet MS/TP or Modbus RTU
Communication
1 | 3 6
Contents
INTRODUCTION
ELECTRICAL
The PLC (Schneider M172P)
Power Supply
Digital Inputs
Digital Outputs
Analog Inputs
Analog Outputs
PLC/HMI Communication
BACnet IP
BACnet MS/TP or Modbus RTU
Programming Port
The HMI (Schneider Magelis HMISTU855)
Power Supply
PLC/HMI Communication
Modbus TCP
Programming Port
The Electrical Interface for the Standard MARK V
Overview
Pump Control Features
Manual Operation
Automatic Operation
Alarms
Tank Charge Mode
SYSTEM SETUP
Control Setup
Quick Setup
Alarm Setup
Pressure Related Alarms
2 | 3 6
Other Alarms
Pump Alternation
Bladder Tank Setup
SYSTEM STARTUP
Pump Speed Control
HMI OPERATING SCREEN
The MARK V User Interface Touchscreen (HMI)
The MARK V Local User Interface (LCD)
COMMUNICATION
BACnet /IP or MS/TP
Modbus TCP/IP
Modbus RTU
3 | 3 6
INTRODUCTION
The E-Series - Mark V is a variable speed booster system with a PLC based controller. This system is capable of controlling up to a four pump package system. The controller employs a user-friendly color touchscreen HMI (Human Machine Interface) to monitor the system conditions, and adjust the system settings.
This system monitors the system discharge pressure via a 4-20 mA signal pressure transducer. This provides a precise pressure control and user flexibility. In addition to this sensor, a suction pressure transducer and/or a flow meter can be added to extend the control and flexibility of the system.
The main objective of this pumping package is to maintain a constant pressure by adjusting the speed and the number of pumps to run according to the building’s demand.
The system is capable of staging pumps on and off based on pressure and/or flow, while alternating pumps to keep the run times balanced between them.
Keeping the energy savings in mind, the pumps will only run when are needed, and while the pressure will be maintained the energy used is kept to a minimum.
The MARK V M172P Control Panel uses the Schneider M172P PLC as the controller and the Magelis
HMIS5T HMI as the Human-Machine Interface. This system can communicate with a SCADA computer via BACnet IP, Modbus TCP/IP and BACnet MS/TP or Modbus RTU simultaneously.
4 | 3 6
ELECTRICAL
The PLC (Schneider M172P)
Power Supply
• 24 VDC at CN10 “+” and “-“
Digital Inputs
• 8 digital inputs (24 VDC)
• CN3 – DI1 and DI2
• CN4 – DI3 ~ DI8
Digital Outputs
• 8 dry contacts
• CN9 – isolated N.O. contacts DO1 and DO2
• CN8 – non-isolated N.O.
contacts DO3 and DO4
• CN7 – non- isolated N.O.
contacts DO5, DO6 and DO7
• CN6 – SPDT contacts DO8+ and
DO8-
Analog Inputs
• CN5 – 8 analog inputs configured as 4~20 mA signals.
Analog Outputs
• CN2 – 4 analog outputs configured as 0~10 VDC signals.
PLC/HMI Communication
• CN19 – RS485-1 (Modbus RTU) connects to the HMI COM port (RJ45)
HMI
COM Port
PLC
RS485-1
Comment
Pin 4 + D+
Pin 5 - D-
Pin 8 GND COM
5 | 3 6
BACnet IP
• Ethernet port located on the upper left top of the M172P controller
BACnet MS/TP or Modbus RTU
• CN19 – RS485-1 can be used as
BACnet MS/TP or Modbus RTU (field selectable via the HMI)
6 | 3 6
The HMI (Schneider Magelis HMISTU855)
Power Supply
• 24 VDC (See item #3 of the HMI graphic above)
PLC/HMI Communication
• The HMI COM port (RJ45) connects to the M172P CN19 – RS485-1 (Modbus RTU). (See item #4 of the HMI graphic above)
Modbus TCP
• Ethernet port. (See item #7 of the HMI graphic above)
Programming Port
• USB mini-B port. (See item #6 of the HMI graphic above)
7 | 3 6
The Electrical Interface for the Standard MARK V
USB
mini-B
CN19
Title:
Project:
Dgn by:
Rev:
Date: Date:
Date:
Chk by:
PN: Sheet of
4034 Mint Way Dallas, Texas 75237
214-337-8780 800-783-6756 www.tigerflow.com engineering@tigerflow.com
PLC and HMI Comms
2 5
The information, data and design contained in this drawing are confidential and proprietary information to TIGERFLOW Systems, Inc. Disclosure or use without the written permission of TIGERFLOW Systems, Inc is prohibited.
NOTE: All wire and conduit sizes shown are minimum required. Larger sizes may be substituted. Use 90 degree C wire for motor wire runs. Include tag reading “MOTOR WIRE TO BE NO LESS THAN 90 C RATED.” Control interface wiring includes tag reading “TORQUE SCREWS TO 6-14 IN-LBS, USE COPPER WIRE ONLY.”
A B C D E F G H I J
A B C D E F G H I J
M172P
CN10
GND
CN1
GND
RJ45 Adapter
8Magelis HMI COM port (RJ45)
24 VDC
Power Supply
RS485-1
RS485-2
BACnet or Modbus
MS/TP
Cable
RS485
D+
D-
SCADA
RS485 Port
Ethernet
BACnet IP
SCADA
Ethernet Port
ProgramPC or Laptop
402 400
POWER SUPPLY
L
N
24 VDC
5A
102 200
CB1 3 Amp CB2 5 Amp
R
Wht
R
PUR
W/P
PUR
PUR
W/P
Yel
Yel
Yel
W
Standard Schneider Mark V CTO
Parsa Tahamzadeh 11/26/2018
8 | 3 6
Level Switch
Flow Switch
P2 Running
P1 Running
CN4
Title:
Project:
Dgn by:
Rev:
Date: Date:
Date:
Chk by:
PN: Sheet of
4034 Mint Way Dallas, Texas 75237
214-337-8780 800-783-6756 www.tigerflow.com engineering@tigerflow.com
Schneider Digital I/O
3 5
The information, data and design contained in this drawing are confidential and proprietary information to TIGERFLOW Systems, Inc. Disclosure or use without the written permission of TIGERFLOW Systems, Inc is prohibited.
NOTE: All wire and conduit sizes shown are minimum required. Larger sizes may be substituted. Use 90 degree C wire for motor wire runs. Include tag reading “MOTOR WIRE TO BE NO LESS THAN 90 C RATED.” Control interface wiring includes tag reading “TORQUE SCREWS TO 6-14 IN-LBS, USE COPPER WIRE ONLY.”
A B C D E F G H I J
A B C D E F G H I J
M172P
CN3
DI1
DI2
DI5
DI6
DI7
Digital Inputs
COM
DI3
DI4
Digital Inputs
COM
DI8
402 400
System Disable (Optional)
System Disable
Flow Switch (Optional)
Level Switch (Optional)
PUR
PUR
PUR
PUR
PUR
Pump 1 Running
Pump 2 Running
PUR
PUR
P/W
PUR
PUR
PUR
P/W
Horn
Run Pump 2
Run Pump 1
M172P
CN9
DO2
C2
DO1
C1 Digital
Outputs
R1 A1A2
R2
CN8
C34
DO3
DO4
Digital Outputs
402 400
CN7
DO7
DO5
DO6
Digital Outputs
C567
Horn
CN6
C8
DO8+
DO8-
Digital Outputs
Pur
Pur
Pur
Pur
Pur
Pur
P/W
P/W
Pur
Wht
Pur
Pur
VFD-1
RUN SC
S1
VFD-2
RUN SC
S1 R2
Blk231
Wht
Blk233
Wht
Run Pump 3 R3
Run Pump 4 R4
R1 11 14
11 14
System Alarm
N.O.
N.C.
CommonSC S1
SC
S1
R4
Blk235
Wht
Blk237
Wht
R3 11 14
11 14
VFD-3
RUN
VFD-4
RUN
PUR
PUR
PUR
PUR
P3 Running
01 02
01 02
01 02
P4 Running 01 02
Pump 3 Running
Pump 4 Running
A1A2
A2 A1
A2 A1
9 | 3 6
Suction
System
Title:
Project:
Dgn by:
Rev:
Date: Date:
Date:
Chk by:
PN: Sheet of
4034 Mint Way Dallas, Texas 75237
214-337-8780 800-783-6756 www.tigerflow.com engineering@tigerflow.com
Schneider Analog I/O
4 5
The information, data and design contained in this drawing are confidential and proprietary information to TIGERFLOW Systems, Inc. Disclosure or use without the written permission of TIGERFLOW Systems, Inc is prohibited.
NOTE: All wire and conduit sizes shown are minimum required. Larger sizes may be substituted. Use 90 degree C wire for motor wire runs. Include tag reading “MOTOR WIRE TO BE NO LESS THAN 90 C RATED.” Control interface wiring includes tag reading “TORQUE SCREWS TO 6-14 IN-LBS, USE COPPER WIRE ONLY.”
A B C D E F G H I J
A B C D E F G H I J
M172P
CN5
AI1
AI2
Analog Inputs
M172P
CN2
GND
AO1
AO2
Analog Outputs
AI3
AI4
AI5
AI6
AI7
AI8
GND
5Vdc
24Vdc
Flow
4~20mA Transducer
4~20mA Transducer
4~20mA Transducer
Pwr Sig
Pwr Sig
Pwr Sig
4~20mA Signals
0~10 Vdc Signals
AO3
AO4
VFD-1
Ref AC
A1 0~10 Vdc
VFD-2
Ref AC
A1
0~10 Vdc Blk
Blk
Blk
Blk
Blk
Pur
Pur
Pur
GND
AC
A1
0~10 Vdc
Blk 253253
AC
A1
0~10 Vdc
VFD-3
Ref
VFD-4
Ref
254 Blk
10 | 3 6
SEQUENCE OF OPERATION
Overview The system is capable of controlling up to four variable speed pumps, controlling the run commands and speed of each pump. The controller consists of an Eaton PLC and a color touchscreen HMI. All System settings can be adjusted via the HMI and includes the following:
• HOA switches for all pumps
• Pump run times
• Pump run status and speed
• Flow (optional)
• Discharge pressure
• Suction pressure (Optional)
• Alarms and status
• Events history
Pump Control Features Each pump has an HOA switch on the main display of the touch screen HMI. Touching an HOA switch toggles the switch between Hand-Off-Auto-Off positions.
In the HAND position the pump runs a fixed user defined speed, the pump is shutdown in OFF position and in the AUTO position the pump is available for automatic operation, in case the pump does not have an active failure alarm.
Auto pump speed is control based on the pressure error (difference between setpoint and current pressure).
Manual Operation To set a pump in the HAND position, touch a pump HOA switch on the left side to select the mode. The pump will start after a 2 second delay. This delay prevents a pump from attempting to start while the
HOA switch passes through the Hand position to reach other modes. The pump will run at the preset manual speed setting located in the lower right corner of the main operating screen. To change the speed, select the Manual Speed value, enter the desired % speed and touch ENTER. Pumps running in
Hand will accelerate or decelerate to the new speed setting.
11 | 3 6
Only the Low Suction Alarm shuts down a pump running in Hand mode. If the pump does not start after the delay, touch Menu and then System Status. If the Low Suction alarm is active, touch Alarm Reset button to deactivate the alarm.
CAUTION: Running pumps in hand position overrides all system safeties and alarm shutdown features with except of low suction.
NOTE: % speed is a percentage of 60 Hz. A pump running at 30 Hz is running at 50% speed. This percentage also relates the 0-10 V DC speed signal being transmitted to a drive.75% speed equates to a 7.5 V DC speed reference signal to the drive. 100% speed equates to a 10.0 V DC speed reference signal to the drive.
Automatic Operation
WARNING: Do not run pumps in automatic prior to proper system setup. Failure to do so could over pressurize building piping.
The automatic operation begins when one or all pumps HOA switches are in the AUTO position. The user defines the pressure that is needed to maintain, as well as the setpoints at which the pumps will stage on and off. When the pumps are in the auto position, they will be commanded to start after an on-time delay (field adjustable) and increase the speed until the minimum required pressure is achieved. The lead pump will always start the operation.
When starting automatically, the lead pump will ramp immediately to the Lead Pump Starting Speed setting. After starting speed is reached, the speed will automatically increase and decrease as necessary to satisfy the system pressure demand. However, the pump speed will NEVER run slower than the minimum pump speed setting.
CAUTION: Pump speed will NEVER be lower than the minimum auto speed setting. This setting is intended to be the speed required to produce the desired boost under no-flow conditions. Failure to take into account the maximum suction pressure conditions while adjusting this setting will result in high pressure alarms. When in doubt set minimum speed 15-20% below the expected no flow speed.
Speed control is equipped with a slowdown routine that slowly ramps the pump to a minimum speed
12 | 3 6
Additional pumps are started based on the pressure error or flow. If one pump is running at full speed and the pressure is still below lag start setpoint (adjustable), the lag pump will be commanded to start.
The on and off time delays, and the setpoints for starting and stopping each lag pumps can be adjusted to meet the demand.
Lag pumps can also start on flow to protect pumps from running at the end of the pump curve. The Lag pumps start on flow setpoints are user defined via the HMI. When the flow reaches the Lag start setpoint for the on-time delay, the pump will start and ramp up to the Lead pump speed.
A special condition where the load is stable at a point that causes the motor to exceed the motor FLA, the controller will add a lag pump after a time delay to protect the motor.
Pump operation is monitored via a VFD run contact on each drive. When commanded to run, a drive is given 30 seconds to close the run contact, in case this fails to happen the VFD / pump is considered to be failed and the next Auto available pump will start. All time delays are field adjustable.
Pump alternation is provided between auto available pumps. Alternation options include auto, manual and timed alternation. The auto alternation will occur each time all pumps are off (pressure above the setpoint), the manual alternation is operator initiated and the timed alternation allows pumps to be alternated either daily, weekly or monthly on a specified day and time.
The alternation rotates the lead pump from one to the other, being this one the one that will start operation first and stop last.
Pump Stop:
Lag pump stops after the lag stop pressure is achieved, the flow rate is lower than the flow start setting for the off-delay time period and the pump auto speed is no longer at 100%. If Allow Lead Pump Stop is selected, lead pump will stop when stop pressure is satisfied AND the pump has ran at the Minimum
Auto Speed setting, for the off-time delay.
Recommendation: Many customers are accustomed to setting long lead pump off-time delays. This is not recommended for the E-Series Mark V. When the minimum auto speed setting is set properly the lead pump will only shutdown during low / no flow conditions. A short lead pump off-time delay setting of 10-30 seconds is recommended to take full advantage of the energy savings and increase pump seal life. A longer off-delay may be useful in a system with a hydro-pneumatic tank to charge.
under no flow conditions. Therefore, even a 0% minimum speed setting is permissible and will allow lead pump shutdown.
13 | 3 6
To better facilitate lead pump shutdown with minimum user setup time, the Mark V is equipped with an auto slow down routine. If only the lead pump is running, pump stop pressure is satisfied, and no automatic speed changes have been made for a time period equal to the lead pump OFF-delay setting, then pump speed is reduced 1% each response time cycle until either the minimum pump speed is achieved or an automatic speed change is made. When minimum pump speed is reached and maintained with the system pressure satisfied for the lead off-delay time, the lead pump stops.
If Never Stop Lead Pump [found on the Speed Control & System Settings menu screen] is selected, the lead pump only stops when pumps alternate.
Alarms The E-Series Mark V controller includes monitoring and alarming when the pressure goes outside the ideal operation conditions, these alarms are the following:
• Low Suction Pressure
• Low System (Discharge pressure)
• High System (Discharge pressure) Each alarm has independent settings and time delays, as well as the manual or automatic reset option setting.
Tank Charge Mode In case that pressure tanks are used, the tanks are shipped pre-charged to 100 psig pressure. Before water is applied to the tank, the pressure should be adjusted to 5 psi below desired system pressure. Set the lead pump stop pressure to be the desired tank charge pressure. This pressure is typically 5 psi above the required building pressure. Set lag pump stop pressure to the required building pressure. A typical setup for a 75 psi system would be as follows:
Start Pressure
(psi)
Stop Pressure
(psi)
ON-Delay
(sec)
OFF-Delay
(sec)
Lead Pump 70 80 1 120
Lag Pump 65 75 10 300
Lag2 Pump 60 75 10 120
By setting the parameters in this manner, it’s ensured that the system will be in a low or no flow state, prior to shut down, and prevents pump short cycling. When the pumps shutdown the tank will supply low/leak flow demand, until the pressure drops below the start pump setting.
14 | 3 6
SYSTEM SETUP
Control Setup
IMPORTANT: Before powering up control panel verify incoming power meets system design requirements. These requirements can be found inside the control panel door in the lower left corner. Starting system with other than the design power could result in damage to controls and motors. This damage VOIDS the TIGERFLOW warranty.
Once proper power feed has been verified, turn ON control power and drive disconnects. After the
HMI has powered up, the screen will show the menu screen.
Quick Setup
For all the systems built and tested at TIGERFLOW, it is fairly simple to set up the pumps for running in the automatic mode:
Quick Setup
From the MAIN screen:
• Put all the pump H-O-A’s to the OFF positions
• Touch the MENU button
From the MENU screen:
Touch the LOG ON button
15 | 3 6
• Enter the correct user name and password to log in:
User Name: L5
Password: 4034
• Return to the MENU screen
• Enter the desired values for all the parameters to control the Lead and Lag pumps, OR
• Touch the “START AUTO SETUP” to allow the controller to calculate the values based on the desired system discharge pressure
• Touch the “SYSTEM SETPOINT” button and enter the desired value
• If a flow meter is available, enter the “PUMP GPM”
• Touch the “AUTO SETUP” button to allow the controller to calculate all pump start/stop values
• Touch the “SAVE” button to save the data
• Touch the “BACK” button to return to the previous screen
Notes: Do not change any parameter here.