36C26125R0012 RFI_3.docx
DOCX document 15 KB Posted
- Solicitation number
- 36C26125R0012
About this file
This is a Request for Information (RFI) response document for solicitation 36C26125R0012 regarding the Consolidate Sterile Supply Rooms project (570-22-219) for the Department of Veterans Affairs Veterans Health Administration. The document addresses a clarification about HVAC equipment installation and control systems. Specifically, it confirms that contractors should plan to install new equipment into the existing network, but if additional supervisory controllers are required due to insufficient network space, this will be treated as a differing site condition eligible for a change order under the contract Changes clauses.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26125R0012 0006.docx | DOCX document | |
| 36C26125R0012 0005.docx | DOCX document | |
| 36C26125R0012 RFI_2.docx | DOCX document | |
| 36C26125R0012 0004.docx | DOCX document | |
| SOW Consolidate Sterile Supply Rooms_Jan 22 .pdf | ||
| 36C26125R0012 0003.docx | DOCX document | |
| CONTRACTOR CERTIFICATION REGARDING SAFETY AND ENVIRONMENTAL.docx | DOCX document | |
| 36C26125R0012 RFIs.docx | DOCX document | |
| 52.209-5 CERTIFICATION REGARDING RESPONSIBILITY MATTERS.docx | DOCX document | |
| 36C26125R0012 0002.docx | DOCX document | |
| Site Visit Log_01-08-2025.pdf | ||
| 36C26125R0012 0001.docx | DOCX document | |
| 570-22-219 Construction Specifications.pdf | ||
| Large Business Subcontracting Plan Template.docx | DOCX document | |
| 570-22-219 Construction Drawings -.pdf | ||
| Price Breakdown.xlsx | XLSX spreadsheet | |
| RFI Form - 36C26125R0012.docx | DOCX document | |
| Wage Determination CA20240018 Oct 18 2024.pdf | ||
| 36C26125R0012_1.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36C26125R0012 | Consolidate Sterile Supply Rooms | Project Number 570-22-219 Request for Information (RFIs)
1. The earlier RFI answers directed the contractor to connect the new HVAC equipment to the existing HVAC DDC. The answer to RFI #1 Dated 1/22/25 now states the contractor is to install the new equipment on the existing network and if there isn’t sufficient network space, due to other projects taking the available space, then the contractor is to coordinate a new supervisory controller installation with the VA COR.
Please confirm in the case a new Supervisory Controller is required to be installed, the matter will be considered a differing site condition and a change order will be issued IAW the contract Changes clauses. The current answer leaves this potential SOW item ambiguous and not clear if this risk is borne by the contractor, or the VA. For clarification and proposal purposes contractor shall anticipate to install the new equipment into the existing network. Any new supervisory controllers required due to insufficient network space will be treated as differing site conditions and a change order will be issued.