S02 - 640-381.MVW.6.2011.2011.MOUNTAIN_VIEW_CENTER.REFLECTED_CEILING_PLAN_LEVEL2.AS6.02.pdf
PDF 324 KB Posted
- Attached to
- Y1DA--640-20-107 MV-HR BMS HVAC CONST
- Solicitation number
- 36C26120B0013
About this file
This reflected ceiling plan document provides details for the construction of a new HVAC system and building management system at the Mountain View Center campus of the Veterans Affairs Palo Alto Health Care System. Key specifications include installing new suspended acoustical tile ceilings, recessed light fixtures, sprinkler heads, linear air diffusers, security cameras and exit signs on level 2 of the medical facility located at 1776 Old Middlefield Road in Mountain View, California. The related solicitation, numbered 36C26120B0013, is seeking offers for the HVAC and controls construction project numbered 640-20-107. Interested vendors are instructed to monitor beta.sam.gov for solicitation details rather than contacting the medical centers directly. The anticipated award date is unspecified.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SD
SD
3 5 64
A
B
C
D
AS3.03
AS3.03
AS3.03
OPEN TO ABOVE
OPEN TO ABOVE
NCF
NCF
NCF
NCF
NCF
NCF
10' - 0"
8' - 0"
8' - 0"
10' - 0" 10' - 0"10' - 0"10' - 0"
9' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0" 10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0" 10' - 0"
10' - 0"
10' - 0"
10' - 0" 10' - 0" 10' - 0"10' - 0" 10' - 0"
10' - 0"
10' - 0"
9' - 0"
10' - 0"
10' - 0" 10' - 0"
9' - 0"
9' - 0"
10' - 0"
10' - 0"
10' - 3"
9' - 0"
NCF
NCF
N C F
N C F
10' - 0"
10' - 0"
CLCL
CL CL
E Q
E Q
E Q
E Q
AS9.05
UPPER
LOBBY
IDF/IT ROOM
ELECT. RM.
KITCHENETTE
HR SPEC.
WORKROOM
SUPR. HR
SPECIALIST
ASST. HR
OFFICER
HR
SPECIALIST
HR OFFICER
(SERVICE
CHIEF)
SMALL
MEETING
SMALL
MEETING
MED.
MEETING
LARGE
MEETING
SMALL
MEETING
ENCLOSED
FILING
WORKROOM
HR
SPECIALIST
(R.A.)
HR
SPECIALIST
(E.A.)
RN OWCP
MGR.
HR
SPECIALIST
(E.B.)
HR
SPECIALIST
(E.R.)
SUPER. HR
SPECIALIST
HR
SPECIALIST
(E.R.)
HR
SPECIALIST
(E.R.)
HR
SPECIALIST
(E.R.)
HR
SPECIALIST
(E.R.)
HR
SPECIALIST
(E.R.)
MEN'S
WOMEN'S
HR
SPECIALIST
RECRUITEMENT
PLACEMENT
POSITION
MGMT. &
CLASS.
HALLWAY
C2-1
VETPRO
LABOR
RELATIONS
FILING
LOUNGE
HALLWAY
C2-3
HALLWAY
C2-7
H A L L W A Y
C -6
HALLWAY
C2-4
HALLWAY
C2-2
ELECT.
CLOSET
W.H. CLOSET
JANITOR
H A L L W A Y
C -5
F11
F11
F10
F10
F11
F10
E Q
E Q
AS9.06
TYP
AS9.06
3 4
A
B
C
D
AS3.03
AS3.03
ALIGN, TYP.
T Y P
"CL CL
T Y P
E Q
T Y P
E Q
A
LI
G N
A
LI
G N
CL
4' - 4 1/4" A
LI
G
N
SF39 SF40
EQ EQ
CL
AS8.06
TYP
KEYNOTESGENERAL NOTES
GYP. BD. CONTROL JOINT
ROOF HATCH
CEMENT PLASTER 1/4" REVEAL
AIRCRAFT CABLE LATERAL SEISMIC BRACING
LEGEND
SUSPENDED GYP. BD. CEILING; PTD P2
SUSPENDED ACOUSTICAL TILE CEILING
CEMENT PLASTER
METAL PANEL CEILING
METAL OPEN GRID CEILING
TELECOM EQUIPMENT; SEE
TELECOM DWGS
1. SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPE AND SCHEDULE
2. CENTER OF ROOM IS ASSUMED WORKPOINT FOR CEILING GRID
U.O.N. CENTER GRID IN ROOM AS SHOWN FOR CORRECT LIGHTING
LAYOUT
3. SPRINKLER HEADS WHERE SHOWN ARE FOR DESIGN INTENT ONLY.
SEE FIRE PROTECTION SPECIFICATION FOR SPRINKLER HEAD
INFORMATION
4. ALL VISIBLE ELEMENTS AND SURFACES ABOVE OPEN CELL CEILING
SHALL BE PAINTED MATTE BLACK
RECESSED LINEAR
DIFFUSER; SMD
SUPPLY DIFFUSER; SMD
RETURN AIR VENT; SMD
EXIT SIGN, SED FOR TYP
AND DIRECTION
1' - 0" CEILING HEIGHT, AFF
SMOKE DETECTOR, SED
LIGHT FIXTURE; SED
SECURITY CAMERA, SEE
SECURITY DRAWINGS
SPRINKLER HEAD
WINDOW SHADE
RECESSED PROJECTION
SCREEN
Office of Construction and Facilities Management
N
DATEREV ISSUE
C o p yr ig h t
S te in b e rg
A rc h it e c ts
A ll R ig h ts
R e s e rv e d
T h e s e
P la n s a n d o r S p e c if ic a ti o n s a re in te n d e d fo r th e s o le b e n e fi t o f S te in b e rg
A rc h it e c ts c lie n t a n d m a y n o t b e u s e d re u s e d ,c o p ie d ,o r re p ro d u c e d in a n y fo rm w it h o u t th e e x p re s s w ri tt e n c o n s e n t o f S te in b e rg
A rc h it e c ts
ARCHITECT
PROJECT #:
DATE:
SCALE:
CLIENT
Steinberg Architects 98 Battery Street, Suite 300 San Francisco, CA 94111
02.09.2011 100% Schematic Design
03.16.2011 100% Design Development
05.02.2011 90% Construction Documents
05.31.2011 100% Construction Documents
A
T
N A
R
No.
EA
T E
S T R
E
N
R3 1/ N
LOF CA
I
OF
C13447
I1
E
S
E
CI
L
NE
N
R
Y
ED A
.TTS EC
C
TI
H
AM
As indicated
1776 OLD MIDDLEFIELD ROAD,
MOUNTAIN VIEW, CA 94043
:3
:4
A
M C
R e vi t Lo ca l\
V A
C e n tr a l2
V E m co m b ri n k.
rv t
1776 OLD MIDDLEFIELD ROAD,
MOUNTAIN VIEW, CA 94043
AS6.02
VAPAHCS Mountain
View Center -
#640-381
REFLECTED CEILING PLAN -
LEVEL 2
10037.00 5.31.2011
VA Palo Alto Health Care System 3801 Miranda Ave. Building 6, C360 Palo Alto, CA 94304
100%
CONSTRUCTION
DOCUMENTS
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - LEVEL 2 1
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - UPPER ROOF 2
File details come from the government source that posted it. Updated .