S02 - 640-381.MVW.6.2011.2011.MOUNTAIN_VIEW_CENTER.REFLECTED_CEILING_PLAN_LEVEL1.AS6.01.pdf
PDF 570 KB Posted
- Attached to
- Y1DA--640-20-107 MV-HR BMS HVAC CONST
- Solicitation number
- 36C26120B0013
About this file
This reflected ceiling plan is for the Mountain View Center located at 1776 Old Middlefield Road in Mountain View, California. The plan provides specifications for the ceiling finishes, lighting fixtures, sprinkler heads, security cameras, and other components on level 1 of the facility. Key areas on this level include the main lobby, large conference room, computer room, employee development area, staff break room, electrical room, janitorial closets, men's and women's restrooms, elevator machine room, nurse recruiting office, multiple meeting rooms for staff nurses and personnel, storage rooms, audio/visual closets, and hallways. Ceiling heights vary between 8 and 11 feet. Suspended gypsum and acoustical tile ceilings are specified along with other finishes such as cement plaster, metal panels, and open grids. Notation is made regarding lighting layout and sprinkler head placement.
The related federal contract opportunity is a solicitation for project number 640-20-107, the MV-HR BMS HVAC construction project at the Mountain View Center. The pre-solicitation originally published as RFP 36C26120R0012 has been re-identified as IFB 36C26120B0013. Interested parties should visit beta.sam.gov to search for additional details. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration VISN 21.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SD
SD
3 5 64
A
B
C
D
AS3.03
AS3.03
AS3.03
NCF
NCF
NCF
10' - 0"
10' - 0"
8' - 0"
8' - 0"
9' - 11"9' - 11"
10' - 0"
10' - 0"
10' - 0" 10' - 0"
9' - 0"
10' - 0" 10' - 0" 10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
9' - 0"
9' - 0"
11' - 0"
9' - 11"
10' - 0"
10' - 0" 10' - 0"
10' - 0"
9' - 0"
9' - 0"
10' - 0"
10' - 0"
9' - 0"
10' - 0"
10' - 0"
9' - 0"
10' - 0"
EQ EQ
CL
E Q
E Q
CLCL
ALIGN
ALIGN, TYP
EQ EQ EQ EQ EQ
EQ EQ EQ
ALIGN SOFFIT REVEAL TO
ADJACENT VERTICAL WALL
REVEAL, TYP.
ALIGN SOFFIT REVEAL TO
ADJACENT VERTICAL WALL
REVEAL, TYP.
EQ EQ EQ
ALIGN
TYP
TYP
EQ EQ
CL
CL
10' - 0"
EQ EQ
CL
EQ EQ
CL
AS9.05
Sim
MAIN LOBBY
LARGE
CONFERENCE
COMPUTER
ROOM
EMPLOYEE
DEVELOPMENT
STAFF
BREAKROOM
ELECTRICAL
ROOM
JAN.
MEN'S
WOMEN'S
ELEV. MACH.
RM.
NURSE
RECRUITING
MEETING RM.
140-D
STAFF NURSE
140-A
STAFF NURSE
140-C
NURSE
SUPERVISOR
140-B
PERSONNEL
SECURITY
P.S.S.
150-E
PERS.
SECURITY
CHIEF
150-D
EOD COORD
150-A
EOD COORD
150-B
P.S.S.
150-C
STAIRWELL
OFFICE
122-A
HALLWAY
C1-2
HALLWAY
C1-1
STORAGE
STORAGE
AV CLOSET
AV CLOSET
10' - 0"
10' - 0"
AS9.06
AS9.06
AS9.06
AS9.15
TYP
AS9.05
AS9.02
TYP
KEYNOTESGENERAL NOTES
GYP. BD. CONTROL JOINT
ROOF HATCH
CEMENT PLASTER 1/4" REVEAL
AIRCRAFT CABLE LATERAL SEISMIC BRACING
LEGEND
SUSPENDED GYP. BD. CEILING; PTD P2
SUSPENDED ACOUSTICAL TILE CEILING
CEMENT PLASTER
METAL PANEL CEILING
METAL OPEN GRID CEILING
TELECOM EQUIPMENT; SEE
TELECOM DWGS
1. SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPE AND SCHEDULE
2. CENTER OF ROOM IS ASSUMED WORKPOINT FOR CEILING GRID
U.O.N. CENTER GRID IN ROOM AS SHOWN FOR CORRECT LIGHTING
LAYOUT
3. SPRINKLER HEADS WHERE SHOWN ARE FOR DESIGN INTENT ONLY.
SEE FIRE PROTECTION SPECIFICATION FOR SPRINKLER HEAD
INFORMATION
4. ALL VISIBLE ELEMENTS AND SURFACES ABOVE OPEN CELL CEILING
SHALL BE PAINTED MATTE BLACK
RECESSED LINEAR
DIFFUSER; SMD
SUPPLY DIFFUSER; SMD
RETURN AIR VENT; SMD
EXIT SIGN, SED FOR TYP
AND DIRECTION
1' - 0" CEILING HEIGHT, AFF
SMOKE DETECTOR, SED
LIGHT FIXTURE; SED
SECURITY CAMERA, SEE
SECURITY DRAWINGS
SPRINKLER HEAD
WINDOW SHADE
RECESSED PROJECTION
SCREEN
Office of Construction and Facilities Management
N
DATEREV ISSUE
C o p yr ig h t
S te in b e rg
A rc h it e c ts
A ll R ig h ts
R e s e rv e d
T h e s e
P la n s a n d o r S p e c if ic a ti o n s a re in te n d e d fo r th e s o le b e n e fi t o f S te in b e rg
A rc h it e c ts c lie n t a n d m a y n o t b e u s e d re u s e d ,c o p ie d ,o r re p ro d u c e d in a n y fo rm w it h o u t th e e x p re s s w ri tt e n c o n s e n t o f S te in b e rg
A rc h it e c ts
ARCHITECT
PROJECT #:
DATE:
SCALE:
CLIENT
Steinberg Architects 98 Battery Street, Suite 300 San Francisco, CA 94111
02.09.2011 100% Schematic Design
03.16.2011 100% Design Development
05.02.2011 90% Construction Documents
05.31.2011 100% Construction Documents
A
T
N A
R
No.
EA
T E
S T R
E
N
R3 1/ N
LOF CA
I
OF
C13447
I1
E
S
E
CI
L
NE
N
R
Y
ED A
.TTS EC
C
TI
H
AM
As indicated
1776 OLD MIDDLEFIELD ROAD,
MOUNTAIN VIEW, CA 94043
:3
:3
A
M C
R e vi t Lo ca l\
V A
C e n tr a l2
V E m co m b ri n k.
rv t
1776 OLD MIDDLEFIELD ROAD,
MOUNTAIN VIEW, CA 94043
AS6.01
VAPAHCS Mountain
View Center -
#640-381
REFLECTED CEILING PLAN -
LEVEL 1
10037.00 5.31.2011
VA Palo Alto Health Care System 3801 Miranda Ave. Building 6, C360 Palo Alto, CA 94304
100%
CONSTRUCTION
DOCUMENTS
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - LEVEL 1 1
File details come from the government source that posted it. Updated .