100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127 Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

COVER

11/12/2021 DE BWW

GI001

VICINITY MAP

SHEET INDEX

VETERANS AFFAIRS (VA) MEDICAL CENTER

OKLAHOMA CITY, OK 73104

PROJECT #: 635-22-127 (VEG 21.07)

ASBESTOS ABATEMENT AND REMEDIATION

P l a n

N o r t h

True North

3D AERIAL IMAGE

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

NE 13th STREET

NORTH

KE

LL

Y A

VE

NO

RT

H

KE

LL

EY

A

VE

NE 13th STREET

PROJECT SITE

SHEET

NO.

SHEET NAME

GENERAL

GI001 COVER SHEET

GI002 SYMBOLS, ABBREVIATIONS &

CALL-OUTS

ASBESTOS ABATEMENT

HA001 SUB-BASEMENT ASBESTOS SURVEY

HA002 SUB-BASEMENT ASBESTOS SURVEY

HA003 SUB-BASEMENT ASBESTOS SURVEY

HA004 BASEMENT FLOOR ASBESTOS SURVEY

HA005 BASEMENT FLOOR ASBESTOS SURVEY

HA006 BASEMENT FLOOR ASBESTOS SURVEY

HA007 GROUND FLOOR ASBESTOS SURVEY

HA008 GROUND FLOOR ASBESTOS SURVEY

HA100 FIRST FLOOR ASBESTOS SURVEY

HA101 FIRST FLOOR ASBESTOS SURVEY

HA102 FIRST FLOOR ASBESTOS SURVEY

HA201 SECOND FLOOR ASBESTOS SURVEY

HA202 SECOND FLOOR ASBESTOS SURVEY

HA203 SECOND FLOOR ASBESTOS SURVEY

HA301 THIRD FLOOR ASBESTOS SURVEY

HA302 THIRD FLOOR ASBESTOS SURVEY

HA303 THIRD FLOOR ASBESTOS SURVEY

HA401 FOURTH FLOOR ASBESTOS SURVEY

HA402 FOURTH FLOOR ASBESTOS SURVEY

HA403 FOURTH FLOOR ASBESTOS SURVEY

HA501 FIFTH FLOOR ASBESTOS SURVEY

HA502 FIFTH FLOOR ASBESTOS SURVEY

HA503 FIFTH FLOOR ASBESTOS SURVEY

HA601 SIXTH FLOOR ASBESTOS SURVEY

HA602 SIXTH FLOOR ASBESTOS SURVEY

HA603 SIXTH FLOOR ASBESTOS SURVEY

HA701 SEVENTH FLOOR ASBESTOS SURVEY

HA702 SEVENTH FLOOR ASBESTOS SURVEY

HA703 SEVENTH FLOOR ASBESTOS SURVEY

HA801 EIGHTH FLOOR ASBESTOS SURVEY

HA802 EIGHTH FLOOR ASBESTOS SURVEY

HA803 EIGHTH FLOOR ASBESTOS SURVEY

HA901 NINTH FLOOR ASBESTOS SURVEY

HA902 NINTH FLOOR ASBESTOS SURVEY

HA903 NINTH FLOOR ASBESTOS SURVEY

HA910 PENTHOUSE FLOOR ASBESTOS SURVEY

HA911 PENTHOUSE FLOOR ASBESTOS SURVEY

HA912 PENTHOUSE FLOOR ASBESTOS SURVEY

NE 13th STREET

NO

RT

H

KE

LL

EY

A

VE

NO

RT

H

PH

ILL

IP

S

AV

E.

NE 15th STREET

NE 16th STREET NE 16th STREET

NO

RT

H

PH

ILL

IP

S

AV

E.

NE 14th STREET

NE 15th STREET

DRAWING SYMBOLS

26-SF 3

26-TU-I-I

DETAIL NUMBER

DRAWING NUMBER WHERE SHOWN

SECTION LETTER

TYPICAL UNIT NO.

BUILDING NO. WHERE EQUIPMENT IS LOCATED.

SUPPLY FAN NO. 3 IN BUILDING NO. 26

EQUIPMENT ABBREVIATION (SUPPLY FAN)

ITEM NUMBER (TERMINAL UNIT NO. 1)

ITEM (TERMINAL UNIT SHOWN)

SERVED BY AIR HANDLER UNIT NO. 1

DRAWING NUMBER WHERE DRAWN

BUILDING NO. WHERE EQUIPMENT IS LOCATED

H4

H7

A

GENERAL PIPING SYMBOLS

FE

AV

MV

SCH

SH

TH

PS

RC

WB

CSH

SS

* TYPE NUMBERS REFER TO MANUFACTURER'S STANDARDIZATION SOCIETY STANDARD PRACTICE SP-58

VR

CTPS

CTPD

FWPS

FWPD

CF

FWS

BWS

CBD

BO

TC

A

OFL

HW

SW

CW

FOR

FOS

LPG(I)

G(I)

G

HVAC PIPING SYMBOLS

HPS

HPR

MPS

MPR

LPS

LPR

PC

HWS

HWR

GHS

GHR

V

SWS

SWR

CWR

CHR

GCR

RL

RS

RHG

CWS

CHS

GCS

MW

D

GRR

GRS

X

HIGH PRESSURE STEAM (60 PSIG AND ABOVE)

HIGH PRESSURE STEAM CONDENSATE RETURN

MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)

MEDIUM PRESSURE STEAM CONDENSATE RETURN

LOW PRESSURE STEAM (15 PSIG AND BELOW)

LOW PRESSURE STEAM CONDENSATE RETURN

CONDENSATE PUMP DISCHARGE

HEATING WATER SUPPLY

HEATING WATER RETURN

GLYCOL-WATER HEATING SUPPLY

GLYCOL-WATER HEATING RETURN

SOLAR WATER SUPPLY

SOLAR WATER RETURN

REFRIGERANT LIQUID

REFRIGERANT SUCTION

REFRIGERANT HOT GAS

CONDENSER WATER SUPPLY (FROM TOWER)

CONDENSER WATER RETURN (TO TOWER)

CHILLED WATER SUPPLY

CHILLED WATER RETURN

CHILLED GLYCOL-WATER SUPPLY

CHILLED GLYCOL-WATER RETURN

MAKE-UP WATER

DRAIN LINE

VENT LINE

GLYCOL-WATER RUN AROUND SUPPLY

GLYCOL-WATER RUN AROUND RETURN

EXISTING PIPE TO BE REMOVED

FEEDWATER PUMP DISCHARGE

FEEDWATER PUMP SUCTION

CONDENSATE TRANSFER PUMP DISCHARGE

CONDENSATE TRANSFER PUMP SUCTION

VACUUM CONDENSATE RETURN

TUBE CLEANER WATER SUPPLY

BOILER BLOWOFF

CONTINUOUS BLOWDOWN

BOILER WATER SAMPLE

FEEDWATER SAMPLE (FROM DE-AERATOR)

CHEMICAL FEED

OVERFLOW

COMPRESSED AIR

NATURAL GAS MAIN FUEL

NATURAL GAS IGNITER FUEL

LIQUEFIED PETROLEUM GAS IGNITER FUEL

FUEL OIL SUPPLY

FUEL OIL RETURN

COLD WATER (CITY WATER)

SOFTENED WATER

HOT WATER

ROLLER-TYPE HANGER

VARIABLE SPRING-TYPE HANGER (TYPE 51)*

SPRING CUSHION-TYPE HANGER (TYPE 48 OR 49)*

CLEVIS-TYPE HANGER

TRAPEZE HANGER (PROVIDE U-BOLT PIPE ATTACHMENT

TO TRAPEZE EXCEPT WHERE RH ARE INDICATED)

FLOOR-SUPPORTED PIPE STAND

RISER CLAMP (TYPE 42)*

WALL BRACKET (TYPE 31, 32, 33)*

CONSTANT SUPPORT HANGER (TYPE 54, 55, 56)*

SLIDING SUPPORTS (TYPE 35)*

RH

DIRECTION OF PIPE PITCH (DOWN)

DIRECTION OF FLOW

ANCHOR

REDUCER OR INCREASER

ECCENTRIC REDUCER

TOP CONNECTION, 45° OR 90°

BOTTOM CONNECTION, 45° OR 90°

SIDE CONNECTION

CAPPED OUTLET

RISE OR DROP IN PIPE

UNION

CLEAN OUT

PIPE UP

PIPE DOWN

INVERTED BUCKET TRAP SET INCLUDING

PIPING ACCESSORIES SEE DETAIL

FLOAT & THERMOSTATIC TRAP SET INCLUDING

PIPING ACCESSORIES SEE DETAIL

THERMOSTATIC TRAP SET INCLUDING

PIPING ACCESSORIES SEE DETAIL

THERMOMETER

PRESSURE GAGE

FLOW ELEMENT

REFRIGERANT SIGHT GLASS

TEST PLUG (PRESSURE/TEMPERATURE)

AUTOMATIC AIR VENT

MANUAL AIR VENT

QUICK-COUPLE HOSE CONNECTOR

CONNECT TO EXISTING

LIMIT OF DEMOLITION

AIR SEPARATOR

LC

M

VALVE SYMBOLS

GATE VALVE - THREADED/FLANGED

GLOBE VALVE - THREADED/FLANGED

GATE VALVE WITH 3/4" HOSE ADAPTER

CHECK VALVE

WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)

WYE STRAINER WITH VALVED DRAIN AND QUICK-COUPLE

FLEXIBLE CONNECTION

ANGLE GLOBE VALVE

BUTTERFLY VALVE

BALL VALVE

MODULATING CONTROL VALVE

MODULATING CONTROL BUTTERFLY VALVE

TWO POSITION CONTROL VALVE

THREE-WAY MODULATING CONTROL VALVE

THREE-WAY TWO POSITION CONTROL VALVE

PRESSURE REGULATING VALVE

PRESSURE SAFETY VALVE

AUTOMATIC BALANCING CONTROL VALVE

WATER BALANCE DEVICE

CIRCUIT SETTER VALVE

GATE VALVE WITH GLOBE-VALVED BYPASS

PLUG VALVE

CONTROL VALVE (CV) - FLOAT-OPERATED

PRESSURE REDUCING VALVE (PRV)

WATER LEVEL CONTROLLER

FLOW METER

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127 Project Number

Building Number

Drawing Number

Project Title

Drawn

Drawing Title

Approved:

Phase

Project Director

SYMBOLS, ABBREVIATIONS &

11/12/2021 MB RL

GI002

CALL-OUTS

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

FT-8

GM-1

CTP-1

BI-1

BI-2

DW-3

RR-1

RM-1

DW-1

ST-1

DI-1

LN-2

FT-2

RM-1

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

12" X 12" & 9" X 9" GREEN FLOOR TILE

GASKET MATERIAL

COUNTER TOP

BLOWN IN INSULATION

INSULATION ABOVE REFRIGERATOR - BROWN

DRYWALL JOINT COMPOUND

ROLLED ROOFING, BLACK

ROOFING MASTIC, BLACK

DRYWALL

ROOFING MASTIC, BLACK (F-03-H)

12" X 12" WHITE FLOOR TILE

LINOLEUM FLOORING-GREEN

DUCT INSULATION - CLOTH WRAP, GRAY

VINYL STAIR TREADS & MASTIC - BROWN & BLACK

ASBESTOS CALL-OUTS

INDICATES NEW AREAS OF CONSTRUCTION THAT

SHOULD BE ASBESTOS FREE

INDICATES AREAS WITH CRITICAL

ASBESTOS HAZARDS

VEG 21.07

635-22-127 Project Number

Building Number

Drawing Number

Drawn

Drawing Title

Approved:

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

Project Director

SUB-BASEMENT FLOOR ASBESTOS

11/12/2021 MB RL

HA001

SURVEY

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

KEY NOTES:

KEY PLAN:

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, & RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

KEY NOTES:

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

2PI-1

P l a n

N o r t h

True North

1. REMOVE EXISTING ELBOW, TEES, VALVES, AND ASSOCIATED HANGERS

WHERE NECESSARY.

2. UP TO BA130 COMPRESSOR FOR WALK-IN COOLER.

3. EXISTING 6" DOMESTIC COLD WATER TO PENTHOUSE.

4. EXISTING 4" DHW TO PENTHOUSE.

SEE SHEET HA002

S E

E

S

H E

E T

H

A

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

SUB-BASEMENT FLOOR ASBESTOS SURVEY

(FEEDS CANTEEN)

3/4" CW

3/4" HWR

TO SINK ABV.

3/4" DHWR

3/4" DCW

1/2" DHWR

1-1/2" DHWR

1/2" DHWR

3/4" DHWR

3/4" DHW

1/2" DHWR

3/4"

3/4"

3/4" DCW

3/4" 1"

3/4"

1 1/4"

1" 3/4"

1 1/4"

2"

1 1/4"

3/4"

1/2"

2"

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

3/4" DHW

3/4" DHWR

3/4" DHWR 1/2" DHWR

1/2" DHWR1/2" DHWR

1" DHWR

1/2" DHWR

1" DHW

3/4" DHWR

1 ENTIRE FLOOR

X

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3.

SUB-MECHANICAL ROOMS

TIER 1

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

SUB-BASEMENT FLOOR ASBESTOS SURVEY

SUB-BASEMENT FLOOR ASBESTOS

11/12/2021 MB RL

HA002

SURVEY

KEY PLAN:

GENERAL NOTES

KEY NOTES:

SEE SHEET HA001

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

2PI-1

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

1. REMOVE EXISTING ELBOW, TEES, VALVES, AND ASSOCIATED

HANGERS WHERE NECESSARY.

2. VALVES TO BA130 COMPRESSOR FOR WALK-IN COOLER.

3. EXISTING 1 1/4" DOMESTIC HOT WATER

4. EXISTING 2" DOMESTIC HOT WATER RETURN

5. EXISTING 2" DOMESTIC HOT WATER

6. EXISTING 1" DOMESTIC HOT WATER

7. EXISTING 1/2" DOMESTIC HOT WATER RETURN

8. EXISTING 3/4" DOMESTIC HOT WATER RETURN

9. EXISTING 1" ELBOW

DWH

5. HOT WATER CIRCULATING PUMPS

2. COLD WATER PUMP #1

4. HOT WATER HEATER

3. COLD WATER PUMP #2

1. WATER SOFTNER

A. REFER TO GI001 AND GI002 FOR MECHANICAL AND PLUMBING

SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS

AND REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE

PROCEEDING WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS

ABATEMENT WORK, AND RELATED TYPE, QUANTITY, LOCATION, &

COST OF EACH.

BASEMENT FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS

3/4"

1 1/2"

6"

4"

4" 2"

1 1/2"

1 1/4"

1 1/4"

3"

1 1/4"

1"

1"

1 1/4"

3"

6"

4"

RADIATOR IN GAS METER HOUSE

2 1/2" H. P. DRIP RET.

2 1/2" M. P. STEAM

3" H. P. STEAM

PUMP

CONDENSATE

STEAM VENT

2" L. P. STEAM LINE TO 100°

RADIATOR IN GAS METER HOUSE

1 1/4" M. P. DRIP RET.

2 1/2" M. P. STEAM

1 1/4" VACUUM RET.

4" L. P. FREE STEAM

TO 5,000 GAL

TANK UNDER

BLDG 22

DOMESTIC

WATER

DOMESTIC

WATER

5" LOW PRESSURE FREE STEAM

2" VACUUM RETURN

2 1/2" MEDIUM PRESSURE STEAM

TO BLDG 19

3/4" DHW

1/2"

DHWR

1" DHW

1" DCW

3/4"

DHWR

3/4" DCW

(WALL HYDRANT)

1/2" DHWR

TO CANTEEN

3" STEAM

1/2" DHWR

TO SINK

ABOVE

DRAIN

DRAIN

TO

CONDENSATE

PUMP

TO HW

1 ENTIRE FLOOR

TO CONDENSATE

PUMP

P l a n

N o r t h

True North

TIER 1

SUB-MECHANICAL ROOMS

TIER 1

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3.

BOILER

PLANT

BASEMENT

3"3"

SUB

BASMENT

KEY PLAN:KEY PLAN:

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

SUB-BASEMENT FLOOR ASBESTOS SURVEY

SUB-BASEMENT FLOOR ASBESTOS

11/12/2021 MB RL

HA003

SURVEY

KEY PLAN:

GENERAL NOTES

KEY NOTES:

KEY PLAN:

GENERAL NOTES

KEY NOTES:

S E

E

S

H E

E T

H A

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

2PI-1

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

BASEMENT FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS

1-1/2" DHWR

A. REFER TO GI001 AND GI002 FOR MECHANICAL AND PLUMBING

SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE

PROCEEDING WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

1. REMOVE EXISTING ELBOW, TEES, VALVES, AND ASSOCIATED

HANGERS WHERE NECESSARY.

X

SUB-MECHANICAL ROOMS

TIER 1

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3.

BASEMENT FLOOR ASBESTOS

11/12/2021 DE BWW

HA004

KEY PLAN:KEY PLAN:

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

BASEMENT FLOOR ASBESTOS SURVEY

BASEMENT FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLOWN IN INSULATION 1 (BB105-1, BB105A-1, BB106-1)

STAIRWELLS ARE KNOWN TO HAVE ASBESTOS-CONTAINING VINYL

STAIR TREAD AND MASTIC (BROWN/BLACK)(STAIRWELL 8)

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

BI-1

WHITE DUCT SEALANT

BLOWN IN INSULATION

1,2,3

1,2,3 1,3

1,3

1,3

1,3 122 1,5

2,3

1,3

1,3

1,2

1,3

1,3

3 3

1,3

1,2

1,3

5BT-1TAR SEALANT - BLACK (PIPES/DUCT)

INDICATES NEWLY REMODELED AREAS THAT ARE SHOULD BE ASBESTOS FREE.

BF118 HAS DAMAGED PIPE FITTINGS (PF-1) ON SHEET 4 OF THE TITAN PHOTO LOG

INDICATES NEW AREAS OF CONSTRUCTION THAT SHOULD BE

ASBESTOS FREE

INDICATES AREAS WITH CRITICAL ASBESTOS HAZARDS

P l a n

N o r t h

True North

STR #1

STR #2STR #7

STR #6

STR #10

STR #15

STR #8

CHASE

BF129

BF129a

BF125

BF128

BF127a

BF127

BF125b

BF153

BF130

BF112

BF135

BF136

CBF 9

BF138BF137

BF134

BF133

BF132

BF139

CBF 8

BF155BF140BF113

CBF 10

BF149

BF131

CBF 12

BF146

CBF 11 BF147

BF143b

BF148

CBF 14

BF150

BF145m

CBF 2

BF124 CBF1

BF123

BF121

BF119

BF120

BF154 BF145j

CBF 3

BF145l BF145p

CBF 5

BF116

BF145f

BE102a

BE102b

BE102d

BE100c

BE100BE101

BE100d BE100a

BA119g

BA121

BA119f BA115b

CBA 2CBA 1

BA119c

BF115

BF114

CBF 7

BF145q BF141

BF142

BF143a

BF144CBF 13

BF108

BE102e

BE102

CBF 4

BF145e

BF145dCBF 15

BF145c

BF145

BF145o

BF145n

BE100b BE

2c

BF117

BF145gBF145i BF145h

BF111

BF118aBF118

BA115a

BA116

BA123

BF144a

BA125

BA124 BA126

BA128

BA127

BA118

BA119b

BA119

BA119a BA116a

BA117

BA130a

BA130

BA130b1

BB130b BB107 BB106

BB105

BA131

BB103

CBA 4

CBA 3

BA114BA115 BA111

BB135

BB104

BF145b

BF145a

BF

BA

BF106

BA112e1

BA112b

BA112d

BA112c

BA112

BA112a

BA108

BA109

BA110

BA107

BF144b BF144c

BF144d

BF128

BF128a

BF126

BA100

BA101

CBA 5

BA103

BA104

BB105a

BA113

BA112e

CBB 3

BA102

BB102

BF144e

BF151

BF153a

BF145k

SEE SHEET

HA005

S E

E

S

H E

E T

H A

BF122

BF145g1

ELEV

P-12

ELEV

P-11

ELEV

P-9

ELEV

P-10

ELEV

P-8

ELEV

P-7

ELEV

P-2

ELEV

P-3

ELEV

P-4

ELEV

P-5

ELEV

P-6

BA116a1

TIER 1

TIER 1

TIER 1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 2.

SURVEY

CBB 1

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

BASEMENT FLOOR ASBESTOS SURVEY

BASEMENT FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLOWN IN INSULATION 1 (BB105-1, BB105A-1, BB106-1)

5. BLOWN IN INSULATION 2 - BROWN (ABOVE REFRIGERATORS) (BB108,

BB108A, BB108C, BB108D)

STAIRWELLS ARE KNOWN TO HAVE ASBESTOS-CONTAINING VINYL

STAIR TREAD AND MASTIC (BROWN/BLACK)(STAIRWELL 8)

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

BASEMENT FOOR ASBESTOS

11/12/2021 DE BWW

HA005

BUILDING 5

UPSTAIRS

OFFICE

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BI-1

BI-2

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

BLOWN IN INSULATION

INSULATION ABOVE REFRIGERATOR - BROWN

1 1,2

1,3

1,3

1,3

1,3

1,3

1,3

31,3

1 1

16 16

3,16

P l a n

N o r t h

True North

CO

NC

. R

AM

P

AREAWAY

AREAWAY

AREAWAYAREAWAY AREAWAY

PI

PE

C

HA

SE

STR #3

STR #4

102b

101a

102a1a

102a 102a1

BD100n BD

0l

BD100j

BB116

BC100b

BC100a

CB

C

1- 1A

BC100

BB119

BB118

BB

8a

BB115

BB120 CBB 6

BB108a BB108c BB109

BB110

CBB 4

BB122

BB121

BB121a

BB126

BB130

BB132a

BB133

BB132

BB131

BB124

BB129

BB128

CBB 8

BB107a

BB108

BB108d

CBB 2

BB101

CBB 3 BB102

BB134

CBB 1BA130b

BB106

BB107

BB100

BB133

CBB 1

BB110a BB110a1

BB111

BB123

BB127

CBB 7

BD100m

BD107

BD100k

BD100o

BD100e BD100f

BD100

BD100h

CBD 2-1

BD100cBD100a

BB112

CBB 5

BB

BB113

CBD 1-1

BD

0i

BD

0g BD100b

BD100d

BB117

SEE SHEET

HA004

101a1

KEY PLAN:

ELEV

P-1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 2.

SURVEY

ROOM NO. ROOM NAME ROOM NO. ROOM NAME

BA100 TOILET 100 BUILDING 5 BOILER PLANT

BA101 TELE/DATA CLOSET 100 BUILDING 18 CHILLER PLANT

BA102 ELECTRICAL CLOSET 100a OFFICE BA103 EMS STORAGE 100a CONTROL ROOM BA104 EMS CLEAN LINEN 100a1a TOILET

BA105 ENGINEERING STORAGE 101 OFFICE

BA105a ENGINEERING STORAGE 102 EMERGENCY GENERATOR BA105b ENGINEERING STORAGE BA130b EMS TRASH CART WASH ROOM BA105c ENGINEERING STORAGE BB100 ENG MECHANICAL BA105d ENGINEERING STORAGE BB101 AFGE STORAGE

BA106 SOILED LINEN BB102 CANTEEN STORAGE

BA107 CANTEEN STORAGE BB106 FOOD SVC WALK-IN FREEZER

BA107a TELE/DATA CLOSET BB107 ACQUISITIONS SUPPLY RECEIVING

BA107 TELE/DATA CLOSET BB107a WAREHOUSE LOADING DOCK

BA108 IM OFFICE BB108 FOOD SVC KITCHEN MISC.

BA109 IM OFFICE BB108a FOOD SVC STORAGE BA110 ENG SHOP BB108c FOOD SVC WALK-IN REFRIGERATOR BA111 ENG OFFICE BB108d FOOD SVC STORAGE

BA112 IM FOYER BB109 NUTRITION & FOOD SERVICE WAREHOUSE

BA112a OFFICE BB110 SPS MEDICAL STORAGE BA112b TELEPHONE OPERATORS BB110a FOOD SVC WAREHOUSE BA112c BREAK ROOM BB110a1 FOOD SVC WALK-IN REFRIGERATOR BA112d RESTROOM BB111 IM MULTIPURPOSE BA112e TELEPHONE EQUIPMENT BB112 FEC BA112e1 TELEPHONE EQUIPMENT STORAGE BB113 EMS EQUEPMENT STORAGE

BA113 ACQUISITIONS OFFICE BB114 ELECTRICAL CLOSET

BA114 ACQUISITIONS OFFICE BB115 EMS STORAGE

BA115 ACQUISITIONS GENERAL STORAGE BB116 EMS WAREHOUSE

BA110 ENG SHOP BB117 EMS STORAGE

BA111 ENG OFFICE BB118 EMS STORAGE

BA112 IM FOYER BB118a DRESSING ROOM BA112a OFFICE BB119 EMS STORAGE BA112b TELEPHONE OPERATORS BB120 EMS OFFICE BA112c BREAK ROOM BB121 IM STORAGE BA112d RESTROOM BB121a CLOSET BA112e TELEPHONE EQUIPMENT BB122 EMS STORAGE BA112e1 TELEPHONE EQUIPMENT STORAGE BB123 ELECTRICAL CLOSET

BA113 ACQUISITIONS OFFICE BB124 TELE/DATA CLOSET

BA114 ACQUISITIONS OFFICE BB126 LOCK SMITH

BA115 ACQUISITIONS GENERAL STORAGE BB127 MEN'S RESTROOM

BA116a EMS SOILED LINEN BB128 ENG AC SHOP BA116a ELECTRICAL CLOSET BB129 ENG OFFICE

BA117 NURSING OFFICE BB130 EMS TRASHCART WASH ROOM

BA118 EMS H.A.C. BB131 EMS LINEN CHUTE

BA119 IV STORAGE BB132 ENG EQUIPMENT STORAGE

BA119b LOGISTIC STORAGE BB133 IM STORAGE BA119c PATHOLOGY COOLER BB133 ENG ELECTRICAL SUB-STATION 2 BA119f EOC STORAGE BB134 ENG STORAGE BA119g EOC STORAGE BC100 EMS LAUNDRY BA121 PATHOLOGY STORAGE BC100a EMS OFFICE BA122 OFFICE BC101b EMS SOILED LINEN

BA123 ER BREAKROOM BD100 ENG OFFICE

BA124 EXIT BD100a ENG OFFICE BA125 MEDICAL GAS STORAGE BD100b ENG OFFICE BA126 HAZARDOUS WASTE STORAGE BD100c ENG OFFICE BA127 MEDICAL GAS STORAGE BD100d ENG BREAK ROOM BA128 EXIT BD100g OFFICE BA130 EMS TRASHCART WASH ROOM BD100h ENG ELECTRICAL SHOP BA130a EMS WALK-IN REFRIG. BD100i ENG STORAGE BA130b1 STORAGE BD100j ENG PAINT SHOP BA131 MECHANICAL EQUIPMENT ROOM BD100k ENG CARPENTER SHOP BB102 CANTEEN STORAGE BD100l CLOSET BB103 FOOD SVC STORAGE BD100m TOILET BB104 FOOD SVC DUMBWAITER BD100n ENG OFFICE BB105 FOOD SVC WALK-IN REFRIGERATOR BD100o ENG OFFICE BB105a FOOD SVC WALK-IN FREEZER BD107 SWITCHGEAR ROOM #1

BB106 FOOD SVC WALK-IN FREEZER CBB 1 CORRIDOR

BB107 ACQUISITIONS SUPPLY RECEIVING CBB 1 CORRIDOR

BB130b EMS RED BAG CBB 2 CORRIDOR

BB135 ENG PAINT SHOP CBB 3 CORRIDOR

BE100 BIO MED SHOP CBB 3 CORRIDOR

BE100a BIO MED OFFICE CBB 4 CORRIDOR BE100b X-RAY MAINT CBB 5 CORRIDOR BE100c BIO MED OFFICE CBB 6 CORRIDOR BE100d ELEC. CLO. CBB 6 CORRIDOR

BE101 BIO MED SHOP CBB 7 CORRIDOR

BE102 MAIL ROOM CBB 8 CORRIDOR

BE102a OFFICE CBD 1-1 CORRIDOR BE102b MAIL ROOM CBD 2-1 CORRIDOR BE102c ELEC. CLO. CBC 1-1A CORRIDOR BE102d MECHANICAL ROOM BE102e MAIL ROOM

BF106 H.A.C.

BF107 EMS CLEAN LINEN

BF108 EMS STORAGE

BF111 MECH.

BF112 SUBSTATION #3

BF113 FIRE PUMP

BF114 ELEVATOR ROOM

BF115 EMERGENCY GENERATOR

BF116 MECHANICAL ROOM

BF117 TELE/DATA CLOSET

BF118 MECHANICAL ROOM

BF118a AREAWAY

BF119 CANTEEN STORAGE

BF120 SMOKING ROOM

BF121 TOILET FEMALE

BF122 H.A.C.

BF123 TOILET MALE

BF124 WHEEL CHAIR/STRETCHER

BF125 POLICE

BF125b HOLDING

BF126 POLICE

BF127 LOCKERS

BF127a AMMO STORAGE

BF128 PATIENT RECEIVING

BF128 WAITING

BF128a STORAGE

BF129 DECONTAMINATION

BF129a TOILET

BF130 EXAM ROOM 7

BF131 EXAM ROOM 8

BF132 EXAM ROOM 9 (INFECT. ISOL.)

BF133 EXAM ROOM 10 (INFECT. ISOL.)

BF134 CLEAN LINEN

BF135 X-RAY ROOM

BF136 PSYCH. OBSERVATION

BF137 PSYCH. OBSERVATION

BF138 MEDS.

BF139 EXAM ROOM 6

BF140 EXAM ROOM 5

BF141 SPS STORAGE

BF142 SOILED HOLDING

BF143a STORAGE BF143b STORAGE

BF144 FAST TRACK

BF144a EXAM ROOM BF144b EXAM ROOM BF144c EXAM ROOM BF144d MEDS.

BF144e EXAM ROOM

BF145 TREATMENT ROOM 1

BF145a TREATMENT ROOM 1 BF145a TOILET BF145b TRAUMA ROOM BF145c TREATMENT ROOM 2 BF145d TREATMENT ROOM 3 BF145e NURSE STATION BF145f EXAM ROOM 5 BF145g SLEEP ROOM BF145g1 RESTROOM/SHOWER BF145h TOILET BF145i TREATMENT ROOM 6 BF145j TREATMENT ROOM 7 BF145k H.A.C.

BF145l STORAGE BF145m BREAKROOM/LOCKERS BF145n MEDS.

BF145p OFFICE BF145q STORAGE

BF146 EXAM ROOM 4

BF147 EXAM ROOM 3

BF148 EXAM ROOM 2

BF149 NURSE STATION

BF150 TELE/DATA CLOSET

BF151 ELECTRICAL CLOSET

BF153 ELECTRICAL CLOSET

BF153 INTRTVIEW (TRIAGE)

BF154 FAMILY ROOM

BF155 MECHANICAL ROOM

CBA 1 CORRIDOR

CBA 2 CORRIDOR

CBA 3 CORRIDOR

CBA 4 CORRIDOR

CBA 5 CORRIDOR

CBB 3 CORRIDOR

CBF 1 CORRIDOR

CBF 2 CORRIDOR

CBF 3 CORRIDOR

CBF 4 CORRIDOR

CBF 5 CORRIDOR

CBF 7 CORRIDOR

CBF 8 CORRIDOR

CBF 9 CORRIDOR

CBF 10 CORRIDOR

CBF 11 CORRIDOR

CBF 12 CORRIDOR

CBF 12 CORRIDOR

CBF 13 CORRIDOR

CBF 14 CORRIDOR

CBF 15 CORRIDOR

BA106

BA107a

BA105a

BA105 BA105d

BA105b

BA105c

KEY PLAN:KEY PLAN:

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

BASEMENT FLOOR ASBESTOS SURVEY

P l a n

N o r t h

True North

BASEMENT FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

BASEMENT FLOOR ASBESTOS

11/12/2021 DE BWW

HA006

SR

S E

E

S

H E

E T

H A

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1WHITE DUCT SEALANT

1,2

1 1

BA107

1,3

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 2.

SURVEY

BA104

1,2

B C

D

E

F

KEY PLAN:KEY PLAN:

GROUND FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION (ABATED)

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS (ABATED)

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK SPRAY-ON MASTIC (WALLS)

5. BLACK MASTIC BENEATH FLOOR TILES

6. BLACK TAR SEALANT (PIPES/DUCTS)

7. DRYWALL JOINT COMPOUND

STAIRWELLS ARE KNOWN TO HAVE ASBESTOS-CONTAINING VINYL

STAIR TREAD AND MASTIC (BROWN/BLACK)(STAIRWELL 8)

GF182

GF163a

CG

F

CG

F

CGF 9

CGF 7

CGF 6

GF118

CG

F

CGF 4

GF105

CGF 3

CGF 10

CG

F

GF Hallway 4

GF218

CGF 12

CGF 13

CGF 16

CGF 18

GF HALL 5

GF202d

GF202g

GF213

CGF 19

GF202a

GF205

GF202a1

GF206

CGF 2

CG

F

3A

CGE 6CGF 1

CGA 6

GA143d

GA143f

CGB 3

CGA 1

CGE 2

GA

9a

CGA 3

GB121a

CG

A

CGE 1

CG-7E

CG-8E

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

CGA 2

GF224

GROUND FLOOR ASBESTOS

11/12/2021 DE BWW

HA007

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

GROUND FLOOR ASBESTOS SURVEY

SEE SHEET

HA008

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

DW-3

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

DRYWALL JOINT COMPOUND

2,3,4

GA116

2,4

GA115

2,4

GA114

2,4

GA113

2,4

GA112

GA111GA110

GA109

GA109A GA111A

GA107

GA105

GA106

GA104

2,4

GA117

2,4

GA118

2,3,4

GA119

3,4

GA120

1,3,6

GA121

1,3,6

GA122

1,3,6

GA123

GA124

GA124A

GA125

GA126

GA126A

GA127

GA127A

GA128

GA129

GA130A

GA130

GA128A

GE100

GA131

GA132

GA133

GA134GA135GA136

GA139

GA140

GA140A

GA141GA141A

GA141C GA141F

GA141D GA141E

GA141BGA143B

GE101A

GE101B

GA146 GA145

GA144GA147

GA143C1

GA143C

GA143AGA148GA148AGA148BGA148CGA148DGA148E

GE101IGE101HGE101G

GE101F

GE101D

GE104

GE101E GE103

GE

1C

GE102

GE101C

GF206

GF205

GF204

GF203

GF202

GF199GF200

GF201GF217GF218GF219GF220

GF221

GF222

GF216

GF215

GF214

GF213 GF212

GF209

GF210

GF211

GF208

GF207

GF101A GF101B

GF101

GF101C

GF111 GF110 GF109 GF108 GF107 GF106 GF104 GF103C GF103AGF103B

GF122GF121GF120GF119 GF123

GF124BGF124CGF124D GF124A

GF124GF124E

GF124F GF124G GF125

GF

4H

GF102

GF103D

GF103

GF116

GF117

GF118C

GF118A

GF118B

GF112

GF113

GF114

GF115

GF126

GF127

GF128

GF143

GF144

GF145

GF146

GF159

GF160

GF161

GF162

GF183 GF184 GF185 GF186 GF187 GF188 GF189 GF190 GF191 GF192 GF193 GF194

GF195A

GF195

GF163

GF164

GF165

GF166

GF147

GF148

GF149

GF150

GF142

GF129

GF141 GF140 GF139 GF138

GF130 GF131

GF132 GF133 GF134

GF135 GF136

GF137

GF155GF151

GF154GF153GF152

GF158

GF157 GF156

GF181A

GF172G

GF

2F

GF

2E

GF

2D

GF169 GF170 GF171GF168GF167

GF181 GF172

GF172BGF172C

GF172AGF180

GF179 GF178

GF177

GF176

GF173

GF175

GF173A GF174

GF197

GF196 GF198

GF230

GF229 GF228

GF227

GF226

GF231 GF225

GF226A

GF232

GF233

GF234

GF235

GF236

GF239

GF240

GF238

GF237 GF241

GF242GF243

GF244

GF245GF246GF247

GA131A

GE105

GF100

GA103

GA102

GA101

GA100

GA142B GA142A

GA142

GA142B1

GA142A1

GA143

GB102

GA108

4,10

2,3,4

GA104A

3 3 3 3 3 3 3 3 3 3 3 3

3 3 3 3 3 3 3 3

3,6

2,6

1,2,3,6

1,2,6

4,6

1,2,3

1,2,6

2,6

1,2,6

2,6

2,66

1,2,6

3 3

3 3 3 3 3

3 3 33 3

3 3 3 3 3

3 3 3

3 3 3

3 3

1,3

3 3

3 33

1,3,17

4,17

3,4,17

3,4,17

4,17

4,5GA149

GA150 GA151

GA153 GA154

2,6 2,6

3,4,6 1,3,4,6 2,3,4,6

2,4

GA152

2,3,4,6 3,4 4,6 2,4,6 4 4,5 3 6

2,3,4

3,4,63,4,6,17

3,4,174,17

4,17

3,4,17

3,4,17

2,4

2,4 3,4,6

2,3,4,6

3,4,17

2,6

6 2,3

2,3,6

1,2

GF

H all wa y 1

GF Hallway 2 3

GF

H all wa y 3

3 3,17

2,4,17

3,4,5

3,4

2,3 ,6

2,3,4 2,3,4

GE101

CGB 1

P l a n

N o r t h

True North

EMERGENCY GENERATOR

ROOF

STR #7 STR #2

ST

R

#1

ST

R

#1

CHASE

ELEV

P-4

STR #1

ELEV

P-3

ELEV

P-5

ELEV

P-6

STR #5

STR #9CHASE

STR #8

ELEV

P-9

ELEV

P-10

ELEV

P-7

ELEV

P-8

CH

AS

E

STR #11STR #6

ELEV

P-12

ELEV

P-11

SUB-MECHANICAL ROOMS

TIER 1

TIER 1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

COURTYARDCOURTYARD

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3.

GB121c

GB121c

CGB 1

CGB 2

GB105

GB118

GB109a

CG

B

GB109b

GB113

GD100

CGD 2

CG

D

CGD 3

CGD 4

CGH 7

CGH 3

CGH 2

CGH 4

CGH 5

CGH 8-1

CGH 10-1

CGH 9-1

A

B

C

D

E

F

KEY PLAN:KEY PLAN:

GROUND FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION (ABATED)

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS (ABATED)

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK SPRAY-ON MASTIC (WALLS)

5. BLACK MASTIC BENEATH FLOOR TILES

6. BLACK TAR SEALANT (PIPES/DUCTS)

STAIRWELLS ARE KNOWN TO HAVE ASBESTOS-CONTAINING VINYL

STAIR TREAD AND MASTIC (BROWN/BLACK)(STAIRWELL 8)

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

CGH 1

GROUND FLOOR ASBESTOS

11/12/2021 DE BWW

HA008

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

GROUND FLOOR ASBESTOS SURVEY

SEE SHEET

HA007

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

GB120b

GB121

GB118

GB118A

GB117

GB116

GB115

GB114

GB112

GB111

GB110

GB109

GB108

GD101

GD108GD107

GD101AGD102

GD103GD104GD105

GH101GH102GH103 GH100

GH119

GF105

GH104

GH117

GH118

GH106 GH107 GH108 GH110 GH111 GH115GH114 GH116

GH113GH112GH109

GH109A

GD106C

GD106D

GD106E

GD106

GD106A

GD106B

GD106B1

GD102

GD102BGD102A

GD106G

GD106F

GB104D

GB104C

GB104E GB103

GB104B

GB100

GB101

GB104

GB104F

GB106B

GB104F11 GB106A

GB106

GB106C

GB104L

GB104G

GB104JGB104H

GB104K1GB104K GB107

GB104I

GB119

3,6 2,3

3,63

2,3,4,6

1,2,3

1,2,3

1,2,3,42,3

3,4

1,4

1,2,4,6

2,4 2,6

1,2,4,6

4,6

1,2,6

1,2,4 4

1,2 ,4, GB121d

GB120c

GB120d

GB120e

GB120fGB120

GB120a

1,2

3,4

2,3,5

SIGNIFICANT MOLD GROWTH ON HVAC DUCT ON SHEET 5 OF THE TITAN PHOTO LOG

INDICATES AREAS WITH CRITICAL ASBESTOS HAZARDS

P l a n

N o r t h

True North

ELEV

P-1

ELEV

P-2

TIER 1

TIER 1

TIER 1

TIER 1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3. ALL

ROOF AREAS ARE TIER 2.

SURVEY

TIER 1

(LAUNDRY) ROOF

OPEN TO LOWER

LEVEL OF GD106b

UPPER LEVEL

SEATING

MEDICAL MEDIA &

AUDITORIUM

PI

PE

C

HA

SE

ST

R

#3

ST

R

#4

UPPER LEVEL

ROOF (OF LOWER LEVEL)

FIRST FLOOR ASBESTOS SURVEY

HA100

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

FIRST FLOOR ASBESTOS SURVEY

1E1041E1051E1061E107

C1E 4

1E1081E1091E1101E1111E112

C1 E21E113

1E114 1E115

1E113a

C1E 3

1A127

1A1261A129

1A128

1A125

1A124

1A130a

1A130

1A123

1A122

1A121

1A131a

1A131

C1 A

1A120 1A119 1A118 1A117

C1A 2

1A116 1A116a

1A113a

1A113b 1A113

1A1141A115

1A116a

C1A 5 1A105 1A105b

1A105e1A105d

1A1031A102

1A101 1A100

C1A 4

1B117 C1B 1 1G137

1B100c

1B100d

1B100e1B100h 1B100i1B100j

C1A 3 1B100f

1A140

1B100i11A139b 1A1391A139a

1A132

1A132n

C1A 2-1

1A132m 1A132l

1A132k

1A132j1A132i1A132h

1A132g 1A132f 1A132e 1A132d 1A132c 1A132b 1A132a

C1E 1

C1F 2-1

1F100

C1F 1-1

1F138a

1F137d

1F137c 1F137f

1F137e1F138

C1F 22-1

1F137

1F137b1F137a

C1 F

-1 1F136

1F135a11F135a

1F135 1F134

1F133

1F132

1F131

C1F 19-1

1F130

1F132a1F128d1F128c

1F129

1F128

1F128b

C1 F

-1

1F143 1F144

1F142 1F185

1F141

1F140

1F145

1F185b1F186

C1 F

-1

1F139

1F139a

1F191a

1F191b

1F192

1F191

1F190

1F189

1F188

1F187 1F187d

C1 F

-1

1F187a 1F187b 1F187c

1F128a1

1F128a 1F124a

1F1261F125 1F1241F123d

C1F 10-1

C1F 13-1

1F184

1F183 1F146

1F147

1F147a1F1481F149

1F1821F1091F169

1F146a 1F170

1F1811F168c 1F168d

1F168b C1F 15-1 1F180

1F108

1F107 1F179

1F1681F168a

1F178

1F1771F105a

1F106 1F167d1F167c

1F167b C1F 16-1

1F1671F167a

C1 F

-1

C1F 3-1

1F105

1F104a

1F104

1F102

1F101a 1F103a

1F166 1F166a

1F166b 1F166c

1F101b

1F101c

1F101d 1F1031F164

1F165 1F161b

C1F 4-1

1F1631F162

1F161 1F161a

1F110

1F111

1F112

1F160 1F160a 1F113 C1

F 5-

1F159a 1F159

1F157 1F158

1F1561F114

1F115

C1F 7-1

1F155 1F155a

1F154a1F154 1F116

C1 F

6-

1F153

1F152a

1F151a1F151

1F152

C1F 8-1 1F117

1F118

1F119

1F150C1F 9-1 1F120

1F121

1F122 1F123b

1F123a

1F123c

1F123c1 1F122a

1F123

1F122a1

1F101

1,2,3,6

3,4,5

3,4

3,4,6

3 3,4,6 1,2,3,4,63

2,3,4,62,3,6

3,4,6 2,3,4,6 2,3,4

3,6

2,3

2,3,4,6

3,4,6

2,3,4,6

3,4,6

2,3,4,6

1,2,3

2,3,4,6

2,3,4,6

2,3,4,6

1,2,6 1,2,6

3,5

1,2,61,2,6

1,2,6 1B100g

3 3 3

3 3

3 3

3 3 3 3

3 3

3,4

1,2,6 1,2,6 1,2,6

1,2,6 6 1,2,6 1,2,6

3,4 3,4

3,4

3,4

2,6

1,2,3,6

3,4 3,4 3,4 3,4 3,4 3,4

1A105w4

1A105x

2,3,4,62,3,6

2,6

3 3

3 3

3 3

1B100l

SEE SHEET

HA102

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

SEE SHEET

HA101

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

3,4

2,3

KEY PLAN:KEY PLAN:

BASEMENT FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK MASTIC BENEATH FLOOR TILES

5. BLACK TAR SEALANT (PIPES/DUCTS)

STAIRWELLS ARE KNOWN TO HAVE ASBESTOS-CONTAINING VINYL

STAIR TREAD AND MASTIC (BROWN/BLACK)(STAIRWELL 8)

INDICATES NEW AREAS OF CONSTRUCTION THAT

SHOULD BE ASBESTOS FREE.

P l a n

N o r t h

True North

INDICATES NEWLY REMODELED AREAS AND ARE ASBESTOS FREE

1E100 3,4

1A110 2,3,4,5

ST

R

#1

ST

R

#8

STR #6

STR #7 STR #2

STR #1

ELEV

P-10

ELEV

P-9

ELEV

P-8

ELEV

P-7

ELEV

P-11

ELEV

P-2

ELEV

P-3

ELEV

P-4

ELEV

P-5

ELEV

P-6

TIER 1

TIER 1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

COURTYARD

COURTYARD

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3. ALL

ROOF AREAS ARE TIER 2.

COURTYARD

ROOF

ROOF

H

H

1A109

1A105w3

1A105f

1B116

1G134 1G124 1G122 1G120 C1G 3

1G109 1G111

1G112 1G1131G114

1G107

C1G 1

C1G 4 1G116

1G117

1G101a

1G101

1G105

1G104

C1G 2

1G103

1G1021G100a

1G1001B111g1B111h

C1G 5

1b111h11B111i

C1B 5

1B111j1B111k1B111

C1G 8

1G1261G1271G1281G130 1G118

1G119

C1G 6

1G1211G123

1G125 1G131

1G132

1G133

C1G 7

C1B 2

1B110 1B111a 1B105b 1B105a 1B111b 1B111c 1B111d 1B111e 1B111f1B103x

1B103a

1B102g 1B102f

1B1031B103d

1B103c

1B103e1B103f1B103j

1B103h 1B103g

1B103i

1B103k

C1B 3

1B103l1B103m

1B103n 1B103o 1B103p 1B103q 1B103r 1B103s

1B103t

1B103u 1B103v 1B103w

1G1291B102e

1B102d

1B102c1 1B102c

1B102b

1B102 1B102h

1B102a 1B100m 1B100n

1B100 1B100k

1B100a

1B100b1B100l

C1B 4-1

1,2,3,4,6

1G106

3,4,663,4,64,64

3,4,5

3,4

1,2,3,4,62,4,6 4,64,64,63,4,63,4,6

1,2,6

1,2,3,5

3,6

2,62,3,62,66

3,6

3,6

3,6 3

2,3,6

2,6

2,661,2,6

1,2,3,6

2,6

3 3,6

2,3,6

1,2,3,4,6

FIRST FLOOR ASBESTOS SURVEY

11/12/2021 DE BWW

HA101

KEY PLAN:KEY PLAN:

FIRST FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION (ABATED)

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS (ABATED)

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK SPRAY-ON MASTIC (WALLS)

5. BLACK MASTIC BENEATH FLOOR TILES

6. BLACK TAR SEALANT (PIPES/DUCTS)

THE ROOFING SYSTEM IS KNOWN TO HAVE THE FOLLOWING

ASBESTOS-CONTAINING MATERIALS PRESENT:

1. BLACK TAR

2. BLACK GRAVEL

3. BLACK ROLLED ROOFING

4. BLACK ROOFING MASTIC

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

FIRST FLOOR ASBESTOS SURVEY

SEE SHEET

HA100

SEE SHEET

HA102

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

RR-1

RM-1

RM-1

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

ROLLED ROOFING, BLACK

ROOFING MASTIC, BLACK

ROOFING MASTIC, BLACK (F-03-H)

1B109g

1B109lC1B 6

1B109b

1B108a 1B108a1

1B108

1B106

1B109j

1B109a

1B109k

1B109f1B109e1B109d 1B109g

1B109i

1B107

1B107m

1B107l1B107c

1B107b

1B107a

C1B 7

1B110k1B107d1B107e1B107f

C1B 8 1B107g

1B107h 1B107j3,4,6

4,6

4,6

3,4,6 3,4,6 6

4,6 3,4

2,3,4,6 3,4,6

2,3,4,6 2,3,4,6

2,3,4,6 2,3,4,6

2,3,4

1,2,4,6

1,2,3,4,6

2,3,4

2,3,4,6

1,3 1,2,4

1,2,3,4 1, 4 3,4

1B109h 1,4

1B109c 1,3

1,3 3

3,6

1B107i 3,4,6

P l a n

N o r t h

True North

ELEV

P-1

ST

R

#4

ST

R

#3

STR #12

WATER FOUNTAINS

EMPTY SPACE

FIRE EXT. CLOSET

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3. ALL

ROOF AREAS ARE TIER 2.

1E102

1E101

1E104

1E100

1E103

C1E 5

1A1081A109

1A1071A110

1A106c 1A106b

1A106a1A106d 1A106

C1A 7 1A105x

1A105v

1A105a C1A 6

1A105u 1A105t 1A105s 1A105r

1A105k1A105j

1A105m 1A105n 1A105o

1A105p

1A105q

1A105l1A105i1A105h1A105g1A105f

1G137

1G115 1G110 1G108 1G107

3,4 4 3,4

3,4

3,4

2,3,4,6 2,3,4,6

2,3,4,62,3,4,5

2,3,4,63,4,6 2,3,4,62,4,62,3,4,63,6

2,3,4,62,3,4

2,3,4,63,4,6 2,3,4,6

3,42,3

3 3,4 3,4

2,43,4

2,3,4,6 3,4,6 3,4,6

FIRST FLOOR ASBESTOS

11/12/2021 DE BWW

HA102

KEY PLAN:KEY PLAN:

FIRST FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION (ABATED)

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS (ABATED)

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK SPRAY-ON MASTIC (WALLS)

5. BLACK MASTIC BENEATH FLOOR TILES

6. BLACK TAR SEALANT (PIPES/DUCTS)

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

FIRST FLOOR ASBESTOS SURVEY

S E

E

S

H E

E T

H A

SEE SHEET

HA101

DESCRIPTION HA LABEL

HARD MUDDED FITTINGS

DRAWING LABEL

PF-1

DM-1

M-1

BT-1

SPM-1

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

PIPE INSULATION-STRAIGHT RUNS 2PI-1

P l a n

N o r t h

True North

STR #9

ST

R

#1

STR #5

CHASE

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3. ALL

ROOF AREAS ARE TIER 2.

SECOND FLOOR ASBESTOS

HA201

KEY PLAN:KEY PLAN:

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

SECOND FLOOR ASBESTOS SURVEY

SECOND FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION (ABATED)

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS (ABATED)

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK SPRAY-ON MASTIC (WALLS)

5. BLACK MASTIC BENEATH FLOOR TILES

6. BLACK TAR SEALANT (PIPES/DUCTS)

STAIRWELLS ARE KNOWN TO HAVE ASBESTOS-CONTAINING VINYL

STAIR TREAD AND MASTIC (BROWN/BLACK)(STAIRWELL 8)

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

C2 A

C2 E

C2F 9

C2 F

C2F 3

C2 F

C2

F

2B1282B102j

2B102k

2B102n

2B102m

2A1602A1592A1582A1572A1562A155

2A157a

2A139

2A140

C2 A

C2A 2

C2A 6C2A 4

2A1542A1532A152

2A151

2A1502A150a2A149 2A1612A149a

C2A 3

2A148 2A147 2A146

2A145

2A144 2A143 2A142 2A137c1 2A137c 2A138

2A137b

2A137a 2A137

2A135 2A134

2A136f 2A136e

2A136d 2A136g

2A136c 2A136

2A136b 2A136a

2A133 2A132 2A131

2A130b

2A130

2A127a

2A125a

2E

2E1052E1062E1072E1082E1092E1102E1112E112

C2E 3

2E113 2E1142E115

2E116

2E

7 2E118

C2E 1

C2F 16

C2F 15 2F100

2F1012F102

2F125a

2F 1422F141

C2 F

2F103 2F103b

2F105b 2F103a

2F105

2F102a2F102b

C2F 10

C2 F

C2F 12

2F106 2F

2g

2F

2f

2F

2e

2F

2d

2F

2c

2F108

2F109 2F138

2F139

2F135

2F144

2F

2F

2F

7a 2F

4a

2F140

2F154

2F147

2F125b

2F125d

2F125c

2F124a

C2F 7C2F 5

2F1512F151a 2F152 2F153 2F153a 2F153b

2F150

2F134

2F133

2F132 2F130

2F129a

2F129 2F128 2F127 2F126

2F124b

2F124b1 2F124c

2F124d

2F124d1

C2F 8

C2F 1

2F110

2F110a

2F111a

2F111

2F112

2F1132F113a

2F116 2F117

2F117a2F117b 2F117c

2F117d

2F117e 2F118

2F

9 2F121d

2F121c

2F121l 2F121b 2F121a

2F121

2F121k2F121j2F121i2F121h2F121g2F121f

EGRESS TO 2F121

C2F 2 2F123 2F122

2A100

2A101

2A104 2A103a

2A103b

2A103 2A102

2B129

2B102o

SEE SHEET

HA202

S E

E

S

H E

E T

H A

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

2A129

2A128

2A127

2A125

2E100

3,6

3,6

33,43 33,43,4 1,5

3,4

3,443,4

3,4

3 3

4 3,43,4 3,4

3 3

3,4

3,4

3,4

4 43 3,4

3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4

1,3,4 1,3,4

3,5

1,3,4,5,6

1,6

3 3

3,4

3,4 3,4

3,4

3,4

3,4 3,4

44 3,4

3,4

4 4

4 4

3,4

3 3

3 3 3 3 3,4

33,4

3,4

3,4 4

43,4

4 3,4 4

3,4

3,4

3,44

4 4

3,4 3,4 3,4

3,4

3,4 3,4 3,4

3,4

3,4

3,4

3,4

3,43,4

3,43,43,4

4 4

4 2,3,4

2F107c 2F107b

2F107a

2F107

2F108a

2F106a 2F105

2F105c

2F104d

2F104c2F104e

2F106c

2F104b 2F104a

2F125

2A141

INDICATES NEWLY AREAS OF CONSTRUCTION THAT SHOULD BE ASBESTOS FREE

INDICATES NEW AREAS OF CONSTRUCTION THAT

SHOULD BE ASBESTOS FREE

P l a n

N o r t h

True North

2F124a1

ELEV

P-11

ELEV

P-2

ELEV

P-3

ELEV

P-4

ELEV

P-5

ELEV

P-6

ELEV

P-8

ELEV

P-7

ELEV

P-9

ELEV

P-10

ROOF

ROOF

2F106b

LOCKERS

TIER 1

TIER 1

TIER 1

TIER 1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE

PROCEEDING WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND RELATED TYPE, QUANTITY, LOCATION, & COST OF EACH.

GENERAL NOTES

COURTYARD COURTYARD

ENTIRE FLOOR, WITH THE EXCEPTION OF

ROOMS LABELED "TIER 1", IS TIER 3. ALL

ROOF AREAS ARE TIER 2.

SURVEY

DN

STR #1

STR #2STR #7

STR #8

STR #6

STR

#10

"A" & "E" WING PLUMBING NOTES:

POSSIBLE FIBERGLASS P/C W/ 1% ASBESTOS PAPER

POSSIBLE ASBESTOS P/C W/ 1% ASBESTOS PAPER

ALL OTHER AREAS ARE ASBESTOS FREE

RISERS

POSSIBLE FIBERGLASS P/C W/ 1% ASBESTOS PAPER

"F" WING PLUMBING NOTES:

ALL FLOORS SHALL BE CONSIDERED TO HAVE ASBESTOS

MASTIC UNTIL DETERMINED OTHERWISE

"A" & "E" WING PLUMBING NOTES:

POSSIBLE FIBERGLASS W/ ASBESTOS PAPER

POSSIBLE ROLLED ASBESTOS (2 P/C, (2 RISERS, 10/RISER

ALL OTHER AREAS ARE ASBESTOS FREE

RISERS

ROLLED ASBESTOS INSULATION

2B120

ASBESTOS DUCT TAPE ABOVE IN CEILING

ASBESTOS P/C (PAPER)

2B121

2B122

2B123

2B124

2B125

2B118a

2B119

C2 B

2B118

C2 B

C2

B

2B126d

2B117b 2B117a

2B117

2B116

2B116a 2B1152B114

2B103 C2B 4

2B1132B1122B1112B1102B108

C2B 5 2B105

2B107

2B106

2B104 2B102

2B102a

2B102b

2B

2c

2B

2d2B102s

2B102t 2B102e

2B102r

2B102p

2B102q

2B102f

2B102g

2B100 2B101

2B102h

2B127

2B102i2B102o

2B126

2B126e

2B126a 2B126b

2G100a

2G100

SECOND FLOOR ASBESTOS

11/12/2021 DE BWW

HA202

KEY PLAN:KEY PLAN:

SCALE: 1/16" = 1'-0"

4' 8' 16' 32' 64'0

SECOND FLOOR ASBESTOS SURVEY

SECOND FLOOR ASBESTOS-CONTAINING MATERIALS PRESENT:

1. THERMAL PIPE INSULATION (ABATED)

2. THERMAL ELBOW INSULATION - HARD MUDDED PIPE FITTINGS (ABATED)

3. HVAC DUCT COMPOUND/SEALANT - WHITE & TAN

4. BLACK SPRAY-ON MASTIC (WALLS)

5. BLACK MASTIC BENEATH FLOOR TILES

6. BLACK TAR SEALANT (PIPES/DUCTS)

7. LINOLEUM FLOORING – GREEN (ROOM 2B102D-1)

KEY PLAN

NO SCALE

E

B

D

8 G

HW

C

5 18

E

A

F

100% CONSTRUCTION BID

DOCUMENTS

VEG 21.07

ASBESTOS ABATEMENT AND

REMEDIATION

635-22-127

(VA) MEDICAL CENTER OKLAHOMA CITY, OK 73104

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i t h

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9 10

Project Director

Issued: Date:

750 W HAMPDEN AVE

SUITE #300

ENGLEWOOD CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM

P l a n

N o r t h

True North

SEE SHEET

HA201

SEE SHEET

HA203

DESCRIPTION

HARD MUDDED FITTINGS

HA LABEL

PIPE INSULATION-STRAIGHT RUNS

DRAWING LABEL

PF-1 1

PI-1

DM-1

M-1

BT-1

SPM-1

LN-2

WHITE DUCT SEALANT

MASTIC-BLACK & YELLOW

TAR SEALANT-BLACK (PIPES/DUCTS)

SPRAY ON MASTIC-BLACK (ON BRICK WALLS)

LINOLEUM FLOORING-GREEN

3,4

3,6 3

1,3

3,6

1,3,5

2,3

1,2,3

1,2,3

HA

LL

W

AY

2,64

1,2,4,6

1,2,4,6

2,4,6

2,4,6

2,4,5,6 2,4,5,6 2,4,6 4,6 4,6 3,4,6

3,6

2B126c

P l a n

N o r t h

True North

2B107

2B106

INDICATES AREAS WITH CRITICAL ASBESTOS HAZARDS

ELEV

P-1

TIER 1

TIER 1

A. REFER TO GI002 FOR MECHANICAL AND PLUMBING SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND

REPORT ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING

WITH WORK.

C. REFER TO THE DOCUMENT TITAN OKC VAMC ABATEMENT COST

ESTIMATES - DAMAGED & PER FLOOR - REVISED 09/27/2021 FOR

ADDITIONAL INFORMATION ON EACH TIER OF ASBESTOS ABATEMENT

WORK, AND…