This document is a Technical Data Sheet for the HDC-100 Ultra Heavy-Duty Moisture-Cure Urethane Topcoat System manufactured by Resinwerks, LLC. It provides detailed information on the product's general characteristics, performance, packaging, application, and limitations.

The key details are:

  • HDC-100 is a high-performance topcoat suitable for heavy traffic industrial floors, high foot traffic commercial areas, aviation hangars, and automotive shop flooring. It exhibits long working time, low VOC, high abrasion resistance, and UV stability.
  • The product is available in 1.08-gallon kits and has a 24-month shelf life when stored properly. Suggested application is at 3 mils dry film thickness as a topcoat in conjunction with HDC-100 aggregate.
  • Surface preparation, moisture considerations, and mixing/application instructions are provided. Limitations include not applying over certain existing coatings, new concrete under 28 days old, or in temperatures below 40°F or above 90°F.

The document is a technical data sheet and does not contain information about a specific federal contract opportunity.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL PRODUCT INFORMATION

Colors: Clear and Pigmented Solids Volume: 95%

V.O.C.: Clear: 48 g/l

Pigmented: 81 g/l

Pot-life: 90 Minutes @ 72° F

Mix-Ratio: Mix Full Kit

Cure Schedule: 72° F @ 50% R.H.

To touch: 6-8-Hours To re-coat: 6-8 Hours Minimum

24-Hours Maximum Foot Traffic: 6-8-Hours Heavy Traffic: 24-Hours

Clean-up: Acetone / MEK Application Temp: 50ºF(10ºC) - 90ºF(32.2ºC)

Environment: Interior or Exterior

GENERAL PRODUCT PERFORMANCE

TEST TYPE TEST METHOD RESULT

Hardness ASTM D-2240 Shore D 92

Taber Abrasion ASTM-D-4060 16 mg loss

Tensile Strength ASTM C-307 3,200 psi

Flammability ASTM D 635 Self extinguishing

Impact Resistance ASTM D 2794 180 lb

Flexibility 1/4” cylindrical mandrel ASTMD 522 Pass

Adhesion ASTMD-4541 500+ PSI concrete fracture

Coefficient of Friction ASTM-D 2047 >0.6 / pass

USES:

» Heavy traffic industrial floors » High foot traffic commercial » Aviation hanger topcoats » Automotive shop flooring

ADVANTAGES:

» Long working-time » Low VOC » High abrasion resistance » UV Stable

PACKAGING & SHELF-LIFE

HDC-100 is available in the following kits:

» 1.08-gallon kit (.85-gallons part A in a one-gallon pail +

0.23-gallons part B + 1 lb part C

Shelf-Life::

» 24 months factory sealed and stored at room temperature.

SUGGESTED APPLICATION:

» Apply at thickness of 3 mils dry as topcoat in conjunction with

HDC-100 aggregate.

ANCILLARY PRODUCTS:.

» May be used as a top-coat in conjunction with any Resinwerks coating system.

» For pigmented applications, add in 1-pint of Resinwerks Urethane Pigment.

MATERIAL COVERAGE

WET FILM

THICKNESS

DRY FILM

THICKNESS

APPROXIMATE

COVERAGE

3.2 mils wft 3 mils dft 509 ft2 / gallon (12.5m™/L)

HDC-100™ IS A ULTRA HEAVY-DUTY MOISTURE-CURE URETHANE TOPCOAT

SYSTEM. This remarkably unique formulation exhibits an extremely long working time, yet dries in 10-12 hours. It is best suited as a topcoat and used in conjunction with HDC 100 aggregate to achieve a lightly textured, highly durable finish. Low in VOCs and virtually odor-free, HDC-100 is one of our most versatile and durable industrial flooring wear surfaces.

SKU: 220-0000-3

HDC-100™

TECHNICAL DATA SHEET

RESINWERKS, LLC

7270 GILPIN WAY, SUITE 100

DENVER, CO 80229

SURFACE PREPARATION

HDC-100™ is intended for use as topcoat and is not designed for direct to concrete application. When applying HDC-100 on top of existing coatings, ensure that the previous layer to be coated is clean, dry and free of any dust or contaminants. For applications over existing smooth surfaces, the area to be coated should be to be sanded and tacked (solvent wiped) prior to application to allow for proper inter-coat adhesion.

MOISTURE IN CONCRETE

HDC-100 is not intended for use as a primer. For more information regarding moisture in concrete please contact your local Resinwerks representative.

DE-GREASING OF CONTAMINATED SUBSTRATES

HDC-100 should not be applied over contaminated surfaces. For previously contaminated surfaces, areas to be coated should be heavy sanded or ground. All dust and remaining contaminants should be completely removed prior to coating.

TREATMENT OF JOINTS & CRACKS

Prior to installation of any Resinwerks primer, all joints, cracks and other substrate irregularities must be addressed. For more information on specific joint treatment procedures, please contact your Resinwerks technical services representative.

MIXING INSTRUCTIONS:

» Prior to mixing, all products should be properly acclimated to the local ambient room temperature of 50ºF(10ºC) -90ºF(32.2ºC)

» Thoroughly agitate both part A and Part B separately prior to mixing. Mix complete kit for two minutes using a slow speed jiffy mixer. While mixing, pour complete contents of HDC 100 aggregate into mix, taking care to properly suspend all aggregates.

» For pigmented coatings, post-add Resinwerks Urethane at a rate of 1 pint per kit.

APPLICATION INSTRUCTIONS

» Apply HDC 100 at a rate of approximately 500 square feet per gallon by pan rolling with a 3/8” - 1/4”(10 mm) nap roller.

» For proper appearance, dip the roller in the coating and lightly roll out excess in the application tray. Take care to spread the material evenly and immediately back-roll in a perpendicular fashion.

» Frequently agitate material in both the pan and mixing vessel during application process to keep aggregates properly suspended.

LIMITATIONS

» Do not apply over concrete experiencing ASR » Do not apply over Acrylics or MMA Coatings » Do not apply over existing coatings / sealers that have not been properly abraded and cleaned.

» Do not apply to new slabs < 28-days old » Do not apply over areas wiped with denatured alcohols » Do not apply to concrete < 3500 PSI compression strength » Do not apply product when ambient or room temperature is below 40ºF (4.4ºC) or over 90ºF(32.2ºC) or if the relative ambient humidity is above 85%.

» This product is not recommended for immersion service.

» DEW POINT: Do not apply when dew point is within 5ºF of the ambient temperature.

MAINTENANCE

The long-term performance, appearance, and life expectancy of wear surface products are dependent on an adequate routine maintenance program designed specifically for the installed wear surface. Resinous floor coating systems are nonporous, causing dirt and contaminants to remain on the surface. Recommended maintenance programs consist of frequent and thorough cleaning utilizing a neutral PH cleaner. The frequency of washing will vary depending on floor usage type, traffic and age. Please contact your local Resinwerks technical representative for more information.

NOTES

Thoroughly read all Material Safety Data Sheets prior to use and maintain copies on job-site at all times.

Mock-ups and field test areas are strongly recommended in order to validate performance and appearance related characteristics (including but not limited to color, inherent surface variations, wear, anti dusting, abrasion resistance, chemical resistance, stain resistance, coefficient of friction, etc.) to ensure system performance as specified for the intended use, and to determine approval of the coating system.

Variability in job site conditions (including but not limited to surface preparation, sunlight, humidity, dew point, temperature, etc.) during application of Urethane products may lead to fish-eyes, blistering, pinholes, wrinkling, or out-gassing of air in the concrete and are not product defects.