4. SLC VAMC Fire Alarm Inventory 2020_0915.xlsx
XLSX spreadsheet 97 KB Posted
- Solicitation number
- 36C25920Q0723
About this file
This is a combined synopsis and solicitation for fire alarm and suppression services at the Salt Lake City Veterans Administration Medical Center in Salt Lake City, Utah. The Department of Veterans Affairs, Network Contracting Office 19 is soliciting quotes from service-disabled veteran-owned small businesses to provide preventative maintenance for the Siemens fire alarm system and fire suppression systems. The contract will be awarded as a firm-fixed-price base year plus four option years. Quotes are due by 10:00 AM MT on September 23, 2020 and will be evaluated based on price alone. The apparently successful offeror will be the responsible bidder with the lowest price that does not exceed available funding and is determined reasonable. Specialized experience, training, and licensure are required for personnel working on the Siemens system and meeting NFPA standards. The requirement for fire alarm and suppression may be met through subcontractors. Safety equipment must be provided for all contractor employees.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25920Q0723 0001_1.docx | DOCX document | |
| 36C25920Q0723 0001.doc | DOC document | |
| Questions and Answers.doc | DOC document | |
| 5. Fire Safety Matrix.xlsx | XLSX spreadsheet | |
| 2. SLCVA_FIRE_ALARMS DRAWING PDF.pdf | ||
| 1. Joint Commission Accreditation_Reports.pdf | ||
| 3. FIRE PROTECTION RECORD DRAWINGS.pdf | ||
| WD 2015-5489 REV 11.pdf | ||
| Joint Commission Life Safety and Environment of Care.pdf | ||
| 36C25920Q0723_1.docx | DOCX document | |
| QASP_Fire alarm and supression.pdf | ||
| VHA Directive 7701.pdf | ||
| 36C25920Q0723.docx | DOCX document | |
| VHA Directive 7703.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B1
| VA Hospital Salt Lake City, Utah | |||
| Building 1 Inventory | |||
| Type | Address | Zone | Location |
| Alarm/trouble | 1:157 | 1D15 | MRI Preaction |
| Damoer | 1:117 | 1D31 | Mech Rm |
| Damner | 4:145 | 3D | SICU Pt Rm#9 |
| Duct | 1:116 | 1D31 | MRI Mech Rm |
| Duct | 1:138 | 1B | Pharm AHU |
| Duct | 1:140 | Penthouse | Phvs Theraov 2nd Fl Penthouse |
| Duct | 2:30 | GA | AHU-1 |
| Duct | 2:32 | GA | AHU |
| Duct | 2:33 | GD | AHU |
| Duct | 2:34 | GD | MRIAHU |
| Duct | 2:36 | GB | INP-AHU |
| Duct | 2:58 | GA | IRMS |
| Duct | 2:59 | GB | Pharmacv |
| Duct | 2:159 | 1F | AH1 Sunnlv |
| Duct | 2:160 | 1F | AH1 Return |
| Duct | 3:56 | 3B | AHU-12 |
| Duct | 3:58 | 3B | AHU-6 |
| Duct | 4:39 | 5D | AHU-1 (SICUl |
| Duct | 4:40 | 5D | AHS-1 |
| Duct | 4:42 | 5D | AHS-2 |
| Duct | 4:44 | 5D | AHS-1 |
| Duct | 4:48 | 5A | AH-7 |
| Duct | 4:50 | 5A | AHU-8 |
| Duct | 4:52 | 5A | AHU-9 |
| Duct | 4:54 | 5C | AHU-10 |
| Duct | 4:56 | 5C | AHU-11 |
| Fire Pump | 2:19 | GD | Pumo Rm |
| Fire Pump Trbl | 2:17 | GD | Pumo Rm |
| Heat Detector | 2:141 | 1D | CT Lounae |
| Pull Station | 1:121 | 1AB | Stairwell |
| Pull Station | 1:123 | 1AA | Stairwell / 1A00 Corridor |
| Pull Station | 1:124 | 1AA | Stairwell/ 1D00D Door |
| Pull Station | 1:125 | 1BB | Stairwell |
| Pull Station | 1:126 | 1BA | Stairwell |
| Pull Station | 1:127 | 1BB | Stairwell |
| Pull Station | 1:128 | 1C00C | Corridor |
| Pull Station | 1:129 | 1CA | Stairwell |
| Pull Station | 1:130 | 1D00L | Corridor West Exit |
| Pull Station | 1:132 | 1EA | Stairwell |
| Pull Station | 1:133 | 1E00B | Shelled Rm1E00B |
| Pull Station | 1:134 | 1F03 | Therapy Clinic |
| Pull Station | 1:160 | 1C27 | Rm 1C27 |
| Pull Station | 2:21 | GB | Stairwell |
| Pull Station | 2:22 | GB | Stairwell |
| Pull Station | 2:23 | GC | Corridor/Tunnel |
| Pull Station | 2:24 | GC | Stairwell |
| Pull Station | 2:25 | GA | Gnd Fl Offices |
| Pull Station | 2:26 | GA | Stairwell |
| Pull Station | 2:27 | GA | Stairwell |
| Pull Station | 2:28 | GD | Parkina Garaae |
| Pull Station | 2:29 | GD | Stairwell |
| Pull Station | 2:120 | 2B | Nurses Station |
| Pull Station | 2:121 | 2A | Nurses Station |
| Pull Station | 2:122 | 2A | Stairwell |
| Pull Station | 2:123 | 2D | Nurses Station |
| Pull Station | 2:124 | 2B | Stairwell |
| Pull Station | 2:125 | 2B | Stairwell |
| Pull Station | 2:126 | 2C | Stairwell |
| Pull Station | 2:127 | 2E | Stairwell |
| Pull Station | 2:150 | 1D | CT Hallway |
| Pull Station | 2:155 | 1F | Waitina Room |
| Pull Station | 2:156 | 1F | Reception Area |
| Pull Station | 2:158 | 1F | Bv Elec Rm |
| Pull Station | 3:02 | 3D | Nurses Station |
| Pull Station | 3:21 | 3B | Nurses Station |
| Pull Station | 3:22 | 3A | Nurses Station |
| Pull Station | 3:23 | 3C | Stairwell |
| Pull Station | 3:24 | 3B | Stairwell |
| Pull Station | 3:41 | 3B | Stairwell |
| Pull Station | 3:43 | 3A | Stairwell |
| Pull Station | 3:114 | 4A | Corridor |
| Pull Station | 3:121 | 4A | Stairwell |
| Pull Station | 3:122 | 4A | Stairwell |
| Pull Station | 3:123 | 4B | Stairwell |
| Pull Station | 3:124 | 4D | Nurse Station |
| Pull Station | 3:125 | 4D | Post Recovery Rm |
| Pull Station | 3:126 | 4D | Lobby/Waitina Area |
| Pull Station | 3:145 | 4C | Stairwell |
| Pull Station | 4:16 | 6B | Stairwell |
| Pull Station | 4:17 | 7B | Stairwell |
| Pull Station | 4:21 | 5B | Stairwell |
| Pull Station | 4:22 | 5C | Stairwell |
| Pull Station | 4:23 | 5A | Stairwell |
| Pump Phase Loss | 2:17 | GD | Pump Rm |
| Pump Phase Reversal | 2:19 | GD | Pump Rm |
| Relav | 1:101 | 1D00 | North Tamper |
| Relay | 1:115 | 1B06B | X-Ray Damper |
| Relav | 1:122 | 1C29A | Oxvnen Damper |
| Relay | 1:139 | 1B09 | Pharmacy AHU Test switch |
| Relav | 1:153 | 1B00C | Door Holders |
| Relay | 1:154 | 1B08 | 1st Fl Pad Trouble |
| Relav | 1:159 | 1C31B | Dock Dampers |
| Relay | 2:07 | GB | Door Holders |
| Relay | 2:31 | GA | AHU-1 Test Switch |
| Relay | 2:37 | GB | INP AHU Test Switch |
| Relay | 2:57 | GB | Pad-3 trbl |
| Relay | 2:100 | 2B00A | Door Holders |
| Relay | 2:129 | 2B | 2nd Fl Pad 3 Trouble |
| Relav | 2:149 | 1D | Ct Hallway Dampers |
| Relay | 2:157 | 1F | Pad-3 Trouble |
| Relav | 2:200 | 2A00B | Door Holders |
| Relay | 3:42 | 3B | Pad 3 Trouble |
| Relav | 3:101 | 3A00B | Door Holders |
| Relay | 3:146 | 4B | 4th Fl Pad-3 |
| Relav | 4:05 | 7B | Public Elev Indicator |
| Relay | 4:06 | 6B | Service Elev Indicator |
| Relav | 4:07 | 7B | Public Elev Prim Recall |
| Relay | 4:08 | 7B | Public Elev Sec Recall |
| Relav | 4:09 | 6B | Service Elev Prim Recall |
| Relay | 4:10 | 6B | Service Elev Sec Recall |
| Relav | 4:18 | 6B | Penthouse Pad-3 Trouble |
| Relay | 4:20 | 6B00A | Svc Elev Shunt Trip |
| Relay | 4:24 | 5A01 | Door Holders |
| Relav | 4:29 | 5A | Door Holders |
| Relay | 4:38 | 5B | Pad-3 Trouble |
| Relav | 4:204 | GD | HVAC Shutdown |
| Relay | 4:205 | GD | HVAC Shutdown |
| Smoke Detector | 1:102 | 1A00 | Corridor |
| Smoke Detector | 1:103 | 1B00C | Elev Lobby |
| Smoke Detector | 1:104 | 1B00C | Corridor |
| Smoke Detector | 1:105 | 1B00 | Service Elev Lobby |
B14 & B44 Building 14 & B44 Inventory
| Type | Address | Zone | Location |
| Damoers | 7:31 | 3B | Elec Rm |
| Duct | 3:12 | BB | AC-5 Suoolv |
| Duct | 3:14 | BB | AC-8 Return |
| Duct | 3:42 | BB | AC-4 Return |
| Duct | 3:44 | BB | AC-4 Sunrilv |
| Duct | 3:46 | BB | AC-7 Sunnlv |
| Duct | 3:48 | BB | AC-3 Sunrilv |
| Duct | 3:50 | BB | AC-3 Return |
| Duct | 3:52 | BC | AC-1 Sunrilv |
| Duct | 3:56 | BC | AC-2 Sunnlv |
| Duct | 3:58 | BC | AC-2 Return |
| Duct | 3:60 | BB | AC-5 Return |
| Duct | 4:40 | BB | Ahu-6 Sunnlv |
| Duct | 4:50 | BA | Ahu-2 Return |
| Duct | 4:52 | BA | Ahu-2 Sunnlv |
| Duct | 7:37 | 3B | Between OR Rooms 1&3 |
| Duct | 7:38 | 3B | Between OR Rooms 1&3 |
| Duct Detector | 7:109 | Penthouse | AC-10 Sunnlv |
| Duct Detector | 7:112 | Penthouse | AC-11 Sunnlv |
| Duct Detector | 7:114 | Penthouse | West Sunnlv |
| Duct Detector | 7:116 | Penthouse | East Sunnlv |
| Hat Liaht | 7:150 | SW Elev Equip | SW Hat Liaht |
| Heat Detector | 21:8 | Parkina | Elevator Shaft |
| Heat Detector | 21:9 | Parking | Elevator Mech Room |
| Heat Detector | 21:18 | Parkina | Storaae Room |
| Low Air | 21:22 | Parking | Riser Room |
| Low Air | 21:25 | Parkina | Riser Room |
| Low Air | 21:28 | Parkina | Riser Room |
| Low Air | 21:31 | Parkina | Riser Room |
| NAG Relav | 7:30 | 3B | Elec Rm Damoers |
| Pad-3 | 3:07 | BB | Basement |
| Pad-3 | 4:07 | GB | Gnd Fl Trouble |
| Pad-3 | 4:60 | Bldg 44 | Blda 44 |
| Pad-3 | 5:09 | 1B | 1st Fl Pad |
| Pad"3 | 6:04 | 2B | 2nd Fl Pad |
| Pad-3 | 7:03 | 3B | 3rd fir Pad |
| Phase Reversal | 3:03 | BB | Pumo Rm |
| PIV | 21:32 | Parkino | Parkino Garaoe PIV |
| Power/Phase Loss | 3:02 | BB | Pumo Rm |
| Primarv Recall | 21:35 | Parkino | Parkina Garaae Elevator |
| Pull Station | 3:17 | BC | Stairwell |
| Pull Station | 3:18 | BC | Corridor |
| Pull Station | 3:19 | BC | Corridor |
| Pull Station | 3:20 | BB | Stairwell |
| Pull Station | 4:03 | GA | Ambulance Entrance |
| Pull Station | 4:06 | GB | Corridor |
| Pull Station | 4:13 | GA | Emeroencv Admin Office |
| Pull Station | 4:16 | GA | Corridor |
| Pull Station | 4:17 | GA | Stairwell |
| Pull Station | 4:18 | GA | Main Lobbv |
| Pull Station | 4:20 | GB | Stairwell |
| Pull Station | 4:21 | GC | Stairwell |
| PuII Station | 4:43 | BB | Stairwell |
| Pull Station | 4:48 | BA | Stairwell |
| Pull Station | 4:56 | Bldo 44 | West Door |
| Pull Station | 4:59 | Blda 44 | East Door |
| Pull Station | 5:02 | 1A | Stairwell |
| Pull Station | 5:08 | 1B | Corridor |
| Pull Station | 5:18 | 1B | Stairwell |
| Pull Station | 5:19 | 1C | Stairwell |
| Pull Station | 6:08 | 2B | Corridor |
| Pull Station | 6:13 | 2B | Stairwell |
| Pull Station | 6:19 | 2A | Stairwell |
| Pull Station | 6:20 | 2A | Elev Lobby |
| Pull Station | 6:21 | 2C | Elev Lobbv |
| Pull Station | 7:11 | 3B | Corridor |
| Pull Station | 7:14 | 3A | Stairwell |
| Pull Station | 7:15 | 3B | Stairwell |
| Pull Station | 7:16 | 3C | Stairwell |
| Pull Station | 7:17 | 3C | Stairwell |
| Pull Station | 7:18 | 3A | Nurses Station |
| Pull Station | 7:19 | 3A | Nurses Station |
| Pull Station | 7:35 | 3B | West OR Entrance |
| Pull Station | 7:42 | 3B | O.R Nurse Station |
| Pull Station | 7:43 | 3B | O.R South Entrance |
| PuII Station | 7:44 | 3B | O.R North Entrance |
| Pull Station | 7:107 | Penthouse | WMech Vest |
| Pull Station | 7:108 | Penthouse | E Mech Vest |
| Pull Station | 21:2 | Parkino | FACP Room |
| Pull Station | 21:3 | Parkina | Basement Elev Lobbv |
| Pull Station | 21:4 | Parkina | Lower Level North Stairs |
| Pull Station | 21:6 | Parkina | 1st Floor Elev Lobbv |
| Pull Station | 21:14 | Parkina | Ground Floor Elev Lobby |
| Pull Station | 21:19 | Parkina | 1st Floor North Stairs |
| Puma Control Fault | 3:04 | BB | Puma Rm |
| Puma Runnina | 3:01 | BB | Pumo Rm |
| Relav | 3:11 | BB | Duct Test Sw |
| Relav | 3:13 | BB | Duct Test Sw |
| Relav | 3:21 | BB | Mail Room Roll Uo Door |
| Relav | 3:22 | BB | Med Record Roll Uo Door |
| Relav | 3:41 | BB | Test Switch |
| Relav | 3:43 | BB | Test Switch |
| Relav | 3:45 | BB | Test Switch |
| Relav | 3:47 | BB | Test Switch |
| Relav | 3:49 | BB | Test Switch |
| Relav | 3:51 | BC | Test Switch |
| Relav | 3:55 | BC | Test Switch |
| Relav | 3:57 | BC | Test Switch |
| Relav | 3:59 | BB | Test Switch |
| Relav | 4:41 | BB | Test Switch |
| Relav | 4:49 | BA | Test Switch |
| Relav | 4:51 | BA | Test Switch |
| Relav | 5:14 | 1B00F | Door Holders |
| Relav | 7:55 | 4200 | Elev Sec Recall |
| Relav | 7:56 | 4200 | Elev Pri Recall |
| Relav | 7:57 | 4200A | 4-Elev Primarv |
| Relav | 7:58 | 4200A | 4-Elev Sec |
| Relav | 7:59 | 4200A | 4-Elev mech rm |
| Relav | 7:61 | 4200A | Elev Shunt Trio |
| Relav | 7:67 | E Elev G | Elev Shunt Trio |
| Relav | 7:69 | WElev H | Elev Shunt Trio |
| Relav | 7:100 | 3B00A | Door Holders |
| Relav | 7:103 | Penthouse | W Pad-3 Trbl |
| Relav | 7:118 | Penthouse | AC-3 Shutdown |
| Relav | 7:119 | Penthouse | AC-4 Shutdown |
| Relav | 7:151 | SW Elev Eauio | Prim Recall |
| Relav | 7:152 | SW Elev Eauia | Sec Recall |
| Relav | 7:153 | SE Elev Eauio | Prim Recall |
| Relav | 7:154 | SE Elev Eauio | Sec Recall |
| Relav | 7:159 | SE Elev Eauio | SE Hat Liaht |
| Relav | 21:37 | Parkina | Elevator Mech Room |
| Secondarv Recall | 21:36 | Parkina | Parkina Garaae Elevator |
| Smoke Detector | 3:05 | BC | Elevator Lobbv |
| Smoke Detector | 3:06 | BB | Corridor |
| Smoke Detector | 3:08 | BB | Elevator Lobbv |
| Smoke Detector | 3:09 | BB | Mech Room |
| Smoke Detector | 3:10 | BB | Mech Room |
| Smoke Detector | 4:01 | GA | Corridor |
| Smoke Detector | 4:02 | GC | Elev Lobbv |
| Smoke Detector | 4:04 | GA | Elev Lobbv |
| Smoke Detector | 4:05 | GA | Corridor West |
| Smoke Detector | 4:08 | GC | Corridor |
| Smoke Detector | 4:09 | GC | Corridor |
| Smoke Detector | 4:10 | GB | Corridor West |
| Smoke Detector | 4:11 | GA | Fire Panel Rm |
| Smoke Detector | 4:14 | GA | Emeraencv Admin Sleep |
| Smoke Detector | 4:44 | BA | Elev Lobbv |
| Smoke Detector | 4:45 | BA | Corridor |
| Smoke Detector | 4:46 | BA | Corridor |
| Smoke Detector | 4:47 | BA | Corridor |
| Smoke Detector | 4:57 | Bldq 44 | West |
| Smoke Detector | 4:58 | Blda 44 | East |
| Smoke Detector | 5:01 | 1A | Corridor |
| Smoke Detector | 5:03 | 1A | Corridor |
| Smoke Detector | 5:04 | 1A | Corridor |
| Smoke Detector | 5:05 | 1A | Corridor |
| Smoke Detector | 5:06 | A | Elev Lobbv |
| Smoke Detector | 5:07 | 1C | Corridor |
| Smoke Detector | 5:10 | 1C | Corridor |
| Smoke Detector | 5:11 | 1C | Corridor |
| Smoke Detector | 5:12 | 1C | Corridor |
| Smoke Detector | 5:13 | 1C | Elev Lobbv |
| Smoke Detector | 6:01 | 2A | Corridor |
| Smoke Detector | 6:02 | 2A | Corridor |
| Smoke Detector | 6:03 | 2A | Corridor |
| Smoke Detector | 6:05 | 2A | Corridor |
| Smoke Detector | 6:06 | 2A | Corridor |
| Smoke Detector | 6:07 | 2A | Elev Lobbv |
| Smoke Detector | 6:09 | 2C | Corridor South |
| Smoke Detector | 6:11 | 2B | Corridor |
| Smoke Detector | 6:12 | 2B | Corridor |
| Smoke Detector | 6:14 | 2B | Corridor |
| Smoke Detector | 6:15 | 2C | Elev Lobbv |
| Smoke Detector | 6:22 | 2B | Corridor |
| Smoke Detector | 6:23 | 2B | Elev Lobbv |
| Smoke Detector | 7:01 | 3A | Corridor |
| Smoke Detector | 7:02 | 3B | Corridor |
| Smoke Detector | 7:04 | 3A | Elev Lobbv |
| Smoke Detector | 7:05 | 3C | Corridor North |
| Smoke Detector | 7:06 | 3C | Elev Lobbv |
| Smoke Detector | 7:07 | 3C | Corridor South |
| Smoke Detector | 7:08 | 3C | Elev Lobbv |
| Smoke Detector | 7:09 | 3B | Corridor N East |
| Smoke Detector | 7:12 | 3B | Familv Waitina Lounae |
| Smoke Detector | 7:32 | 3B | O.R Nurses Station |
| Smoke Detector | 7:33 | 3B | Ooeratina Rm 2 |
| Smoke Detector | 7:36 | 3B | Ooeratinq Room 1 |
| Smoke Detector | 7:39 | 3B | Ooeratina Room 3 |
| Smoke Detector | 7:40 | 3B | Ooeratinq Room 4 |
| Smoke Detector | 7:45 | 3B | Ooeratina Room |
| Smoke Detector | 7:46 | 3B | Ooeratinq Room |
| Smoke Detector | 7:52 | 4200 | Elev Eauioment Rm |
| Smoke Detector | 7:53 | 4200 | Elev Eauioment Rm |
| Smoke Detector | 7:54 | 4200 | Elev Eauioment Rm |
| Smoke Detector | 7:62 | 4200A | Elev Mech Rm |
| Smoke Detector | 7:63 | 4200A | Elev Mech Rm |
| Smoke Detector | 7:64 | 4200A | Elev Mech Rm |
| Smoke Detector | 7:65 | 4200A | Elev Mech Rm |
| Smoke Detector | 7:66 | 4200A | Elev Mech Rm |
| Smoke Detector | 7:68 | Phse E Elev Eauio | East Elev Eauio |
| Smoke Detector | 7:70 | Phse W Elev Eauio | West Elev Eauio |
| Smoke Detector | 7:101 | Penthouse | WElev Eauio |
| Smoke Detector | 7:102 | Penthouse | E Elev Eauio |
| Smoke Detector | 21:1 | Parkin□ | FACP Room |
| Smoke Detector | 21:5 | Parkina | Basement Elev Lobbv |
| Smoke Detector | 21:7 | Parkin□ | 1•1 Floor Elev Lobbv |
| Smoke Detector | 21:10 | Parkina | Elevator Mech Room |
| Smoke Detector | 21:15 | Parkin□ | Ground Floor Elev Lobbv |
| Tamner | 3:15 | BC | Backflow Valve |
| Tamoer | 3:16 | BC | PIV |
| Tamoer | 3:23 | BC | Glvcol Looo |
| Tamoer | 3:24 | BC | Glvcol Looo |
| Tamoer | 3:26 | BB | Main Riser |
| Tamoer | 3:28 | BB | B-A Valve |
| Tamoer | 3:30 | BB | B-B Valve |
| Tamner | 3:32 | BB | B-C Valve |
| Tamoer | 3:33 | BB | Main Tamoer |
| Tamner | 3:34 | BB | Valve 01 |
| Tamoer | 3:35 | BB | Valve 02 |
| Tamoer | 3:36 | BB | Valve 03 |
| Tamoer | 3:37 | BB | Valve 04 |
| Tamoer | 3:38 | BB | Valve 05 |
| Tamner | 3:39 | BB | Valve 06 |
| Tamoer | 3:40 | BB | Main Riser Valve 02 |
| Tamper | 3:53 | BB | BB15 |
| Tamper | 4:26 | GC | G-A Valve |
| Tamper | 4:28 | GC | G-B Valve |
| Tamper | 4:30 | GC | G-C Valve |
| Tamper | 4:31 | BA | Backflow Valve |
| Tamper | 4:32 | BA | Bldq PIV |
| Tamper | 4:39 | BA | Above Ceilina |
| Tamper | 5:26 | 1C | 1-A Valve |
| Tamper | 5:28 | 1C | 1-B Valve |
| Tamper | 5:30 | 1C | 1-C Valve |
| Tamper | 6:28 | 2C | 2-A Valve |
| Tamper | 6:30 | 2C | 2-B Valve |
| Tamper | 6:32 | 2C | 2-C Valve |
| Tamper | 21:21 | Parkinq | Riser Room |
| Tamper | 21:24 | ParkinQ | Riser Room |
| Tamper | 21:27 | Parkina | Riser Room |
| Tamper | 21:30 | Parkinq | Riser Room |
| Tamper | 21:33 | Parkina | Backflow Tampers |
| Test Switch | 7:113 | Penthouse | Duct7:112 |
| Test Switch | 7:115 | Penthouse | Duct 7:114 |
| Test Switch | 7:117 | Penthouse | Duct 7:116 |
| Waterflow | 3:25 | BB | Main Riser |
| Waterflow | 3:27 | BB | Zone B-A |
| Waterflow | 3:29 | BB | Zone B-B |
| Waterflow | 3:31 | BB | Zone B-C |
| Waterflow | 4:25 | GC | Zone G-A |
| Waterflow | 4:27 | GC | Zone G-B |
| Waterflow | 4:29 | GC | Zone G-C |
| Waterflow | 4:38 | BA | Above Ceilinq |
| Waterflow | 5:25 | 1C | Zone 1-A |
| Waterflow | 5:27 | 1C | Zone 1-B |
| Waterflow | 5:29 | 1C | Zone 1-C |
| Waterflow | 6:27 | 2C | Zone 2-A |
| Waterflow | 6:29 | 2C | Zone 2-B |
| Waterflow | 6:31 | 2C | Zone 2-C |
| Walerflow | 21:20 | Parkinq | Riser Room |
| Waterflow | 21:23 | Parkina | Riser Room |
| Walerflow | 21:26 | Parkinq | Riser Room |
| Waterflow | 21:29 | Parkina | Riser Room |
| Waterflow/tamper | 7:22 | 3C | Zone 3-A |
| Waterflow/tamper | 7:24 | 3C | Zone 3-B |
| Waterflow/tamper | 7:26 | 3C | Zone 3-C |
| Waterflow/tamper | 7:28 | 3C | Zone 4-A |
| Walerflow/Tamper | 7:122 | 4C | Zone 4-C |
B3 & B47 Building 3 & B47 Inventory
| Type | Address | Zone | Location |
| Sida 47 Pad 3 Trouble | 2:127 | Blda 47 | Blda 47 |
| Duct | 1:036 | GA03 | AHU 1 |
| Duct | 1:114 | IPU | Crawl Space |
| Duct Detector | 2:147 | Penthouse | AHU-X Suooly |
| Duct Detector | 2:148 | Penthouse | AHU-X Return |
| Duct Detector | 2:149 | Penthouse | AHU-X Suoolv |
| Duct Detector | 2:150 | Penthouse | AHU-x Return |
| Duct Detector | 2:151 | Penthouse | AHU3 |
| Duct Detector | 2:152 | Penthouse | AHU2 |
| Duct Detector | 2:155 | Penthouse | AHU-1 |
| Hat Relay | 2:002 | Penthouse | Elev Equip Rm |
| Heat Detector | 2:001 | Penthouse | Elev Eauio Rm |
| Heat Detector | 2:130 | 3000 | Elev Mech Rm |
| Horn triaaer | 2:145 | 2A12C | Elec Rm |
| Horn Triaaer | 2:146 | 2A13C | Elec Rm |
| Horn Triaaer | 2:153 | 2A13C | Elec Rm |
| Pad 3 Trouble | 2:125 | 2801C | Elec Room |
| Pub Prim Recall | 2:143 | 3000 | Elev Mech Rm |
| Pub Sec Recall | 2:144 | 3000 | Elev Mech Rm |
| Pull Station | 1:018 | GA | Corridor/Tunnel |
| Pull Station | 1:019 | GA00A | West Exit |
| Pull Station | 1:020 | GCA | Stairwell |
| Pull Station | 1:021 | GB11 | Loadina Dock |
| Pull Station | 1:022 | GC | Corridor |
| Pull Station | 1:023 | GC11 | Conference Rm |
| Pull Station | 1:024 | GC18A | Office |
| Pull Station | 1:025 | GC15D | Office |
| Pull Station | 1:026 | GB05E | Generator Rm |
| Pull Station | 1:048 | 1A | Hallway |
| Pull Station | 1:049 | 1A20 | Nurse Station |
| Pull Station | 1:050 | 1AA | Stairwell |
| Pull Station | 1:051 | 1B00 | East Entrv Door |
| Pull Station | 1:052 | 1CA | Stairwell |
| Pull Station | 1:053 | 1C30 | Communication Center |
| Pull Station | 1:105 | IPU | 1st Fl N Entrance |
| Pull Station | 1:109 | IPU | pt Fl South |
| Pull Station | 1:112 | IPU | Ground fl South |
| Pull Station | 2:100 | 2C20 | Nurse station |
| Pull Station | 2:122 | 2BA | Stairwell |
| Pull Station | 2:129 | Bldg 47 | East Exit |
| Pull Station | 2:134 | Bldg 47 Vestibule | Vestibule |
| Pull Station | 2:135 | Bldg 47 Kitchen | Kitchen |
| Relay | 1:037 | GA01 | Tunnel Door Holders |
| Relay | 1:120 | 1C | Dampers |
| Shunt Relay | 2:003 | Penthouse | Elev Eauio Rm |
| Smoke Detector | 1:011 | GA | Corridor |
| Smoke Detector | 1:012 | GB | Public Elev Lobby |
| Smoke Detector | 1:013 | GC | Corridor |
| Smoke Detector | 1:014 | GB05 | Elec Rm |
| Smoke Detector | 1:015 | GB00A | Service Elev Lobby |
| Smoke Detector | 1:016 | GA | Corridor/Tunnel |
| Smoke Detector | 1:027 | GA | Telco Node Rm |
| Smoke Detector | 1:041 | 1B00 | Public Elev Lobby |
| Smoke Detector | 1:042 | 1B00A | Service Elev Lobby |
| Smoke Detector | 1:046 | 1A | Hallway |
| Smoke Detector | 1:047 | 1A | Hallway |
| Smoke Detector | 1:054 | 1A | Intersection |
| Smoke Detector | 1:055 | 1A | Hallway |
| Smoke Detector | 1:056 | 1A | Hallway |
| Smoke Detector | 1:057 | 1A | Hallway |
| Smoke Detector | 1:066 | 1C06 | Laundrv Rm |
| Smoke Detector | 1:067 | JC00 | 1C Hallwav |
| Smoke Detector | 1:068 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:069 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:070 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:071 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:072 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:073 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:074 | 1C00 | 1C Hallwav |
| Smoke Detector | 1:103 | IPU | 1st Fl N Entrance |
| Smoke Detector | 1:110 | IPU | 1s1f1 South Hall |
| Smoke Detector | 1:113 | IPU | Crawl Space |
| Smoke Detector | 1:115 | IPU | Crawl Space |
| Smoke Detector | 1:116 | IPU | Crawl Space |
| Smoke Detector | 1:119 | IPU | Crawl Soace |
| Smoke Detector | 2:045 | 2B00B | Corridor By Elev |
| Smoke Detector | 2:046 | 2B | Corridor By Stairs |
| Smoke Detector | 2:047 | 2B02 | Office |
| Smoke Detector | 2:048 | 2B07 | Laundry |
| Smoke Detector | 2:049 | 2B04 | Corridor |
| Smoke Detector | 2:050 | 2B04 | Corridor |
| Smoke Detector | 2:051 | 2B04L | Staff Men's Restroom |
| Smoke Detector | 2:052 | 2B09 | Public Restroom |
| Smoke Detector | 2:053 | 2C03 | Corridor |
| Smoke Detector | 2:054 | 2C01 | Women Staff Restroom |
| Smoke Detector | 2:055 | 2C07 | Dav Room |
| Smoke Detector | 2:056 | 2C07A | Nourishment |
| Smoke Detector | 2:057 | 2C07C | Storaae |
| Smoke Detector | 2:058 | 2C09 | Rm Smoke |
| Smoke Detector | 2:059 | 2C09A | Rm Bathroom |
| Smoke Detector | 2:060 | 2C11 | Rm Smoke |
| Smoke Detector | 2:061 | 2C11A | Rm Bathroom |
| Smoke Detector | 2:062 | 2C13 | Rm Smoke |
| Smoke Detector | 2:063 | 2C13A | Rm Bathroom |
| Smoke Detector | 2:064 | 2C00A | Corridor |
| Smoke Detector | 2:065 | 2C009 | Corridor |
| Smoke Detector | 2:066 | 2C25 | Staff Lounqe |
| Smoke Detector | 2:067 | 2C20 | Nurse Station |
| Smoke Detector | 2:068 | 2C27 | Meds Rm Smoke |
| Smoke Detector | 2:069 | 2C22 | Corridor |
| Smoke Detector | 2:070 | 2C22B | Rm Smoke |
| Smoke Detector | 2:071 | 2C22BA | Rm Bathroom |
| Smoke Detector | 2:072 | 2C22A | Rm Smoke |
| Smoke Detector | 2:073 | 2C22AA | Rm Bathroom |
| Smoke Detector | 2:074 | 2C18A | Rm Smoke |
| Smoke Detector | 2:075 | 2C18G | Corridor |
| Smoke Detector | 2:076 | 2C18B | Storage |
| Smoke Detector | 2:077 | 2C18C | Rm Smoke |
| Smoke Detector | 2:078 | 2C18CA | Rm Bathroom |
| Smoke Detector | 2:079 | 2C18D | Rm Smoke |
| Smoke Detector | 2:080 | 2C18DA | Rm Bathroom |
| Smoke Detector | 2:081 | 2C18F | Rm Smoke |
| Smoke Detector | 2:082 | 2CA8FA | Rm Bathroom |
| Smoke Detector | 2:083 | 2C18E | Storaqe |
| Smoke Detector | 2:084 | 2C15 | Storaqe |
| Smoke Detector | 2:085 | 2C17 | Pl Bathroom |
| Smoke Detector | 2:086 | 2C21AA | Rm Bathroom |
| Smoke Detector | 2:087 | 2C21A | Rm Smoke |
| Smoke Detector | 2:088 | 2C21B | Rm Smoke |
| Smoke Detector | 2:089 | 2C21BA | Rm Bathroom |
| Smoke Detector | 2:090 | 2C21C | Rm Smoke |
| Smoke Detector | 2:091 | 2C21CA | Rm Bathroom |
| Smoke Detector | 2:092 | 2C21D | Storage |
| Smoke Detector | 2:093 | 2C21E | Familv Visit |
| Smoke Detector | 2:101 | 2A00A | Smoke Corridor |
| Smoke Detector | 2:102 | 2A00B | Smoke Corridor |
| Smoke Detector | 2:103 | 2A00A | Smoke Corridor |
| Smoke Detector | 2:104 | 2A00A | Smoke Corridor |
| Smoke Detector | 2:105 | 2A00 | Smoke Corridor |
| Smoke Detector | 2:106 | 2A00 | Smoke Corridor |
| Smoke Detector | 2:107 | 2A00 | Smoke Corridor |
| Smoke Detector | 2:108 | 2A00 | Smoke Corridor |
| Smoke Detector | 2:109 | 2B00 | Public Elev Lobbv |
| Smoke Detector | 2:110 | 2B00A | Service Elev Lobbv |
| Smoke Detector | 2:111 | 2B05 | Corridor to C |
| Smoke Detector | 2:112 | 2C00 | Corridor |
| Smoke Detector | 2:113 | 2C00 | Corridor |
| Smoke Detector | 2:114 | 2C00 | Corridor |
| Smoke Detector | 2:115 | 2C00 | Corridor |
| Smoke Detector | 2:116 | 2C00A | Corridor |
| Smoke Detector | 2:117 | 2C00A | CD Corridor |
| Smoke Detector | 2:133 | Bldg 47 1A97B | Elec Rm |
| Svc Prim Recall | 2:141 | 3000 | Elev Mech Rm |
| Svc Sec Recall | 2:142 | 3000 | Elev Mech Rm |
| Tamper | 1:038 | GB02 | Blda P.I.V |
| Tamper | 1:040 | BG05B | Under Floor Valve |
| Temp Heat | 2:170 | Ground Floor | Construction |
| Temp Heat | 2:171 | Ground Floor | Construction |
| Temp Heat | 2:172 | Ground Floor | Construction |
| Temp Heat | 2:173 | Ground Floor | Construction |
| Temp Heat | 2:174 | Ground Floor | Construction |
| Temp Heat | 2:175 | Ground Floor | Construction |
| Test Switch | 2:154 | Penthouse | AHU-1 |
| Trouble | 1:017 | GB05A | Pad Trouble |
| Trouble | 1:065 | 1B03 | Pad Trouble |
| Trouble | 1:102 | IPU | Courtvard Elec Rm |
| Waterflow & Tamper | 1:030 | GAA | Zone G-A |
| Waterflow & Tamper | 1:032 | GBA | Zone G-B |
| Waterflow & Tamper | 1:034 | GCA | Zone G-C |
| Waterflow & Tamper | 1:043 | IPU | Zone 1-B |
| Waterflow & Tamper | 1:059 | 1AA | Zone 1-A |
| Waterflow & Tamper | 1:061 | 1BA | Crawl Space |
| Waterflow & Tamper | 1:063 | 1CA | Zone 1-C |
| Waterflow & Tamper | 1:106 | IPU | IPU Lobby Above Celling |
| Waterflow & Tamper | 1:117 | IPU | Crawl Space |
| Walerflow & Tamper | 2:118 | 2AA | Zone 2-A |
| Waterflow & Tamper | 2:131 | Blda 47 1A97B | Riser Rm |
| Waterflow & Tamper | 2:156 | 2CA | Zone 2-C |
| Waterflow & Tamper | 2:159 | 2BA | Zone 2-B |
B2 & B45 Building 2 & B45 Inventory
| Type | Address | Zone | Location |
| Alt Recall | 2:141 | WElev. | Pent West Elev. |
| Alt Recall | 2:143 | E Elev. | Pent East Elev. |
| Damoer | 2:36 | GC | GC19 Damoer Hallwav |
| Door | 2:35 | G | Door Mao. E Hall |
| Doors | 2:147 | 2D | Sec. Door release |
| Doors | 2:148 | 2D | Sec. Door release |
| Duct | 2:15 | GD | South Mech Rm |
| Duct | 2:20 | GD | South Mech Rm |
| Duct | 2:21 | GD | South Mech Rm |
| Duct | 2:41 | 1C | Between Restrooms |
| Duct | 2:42 | 1C | AHU in Office |
| Duct | 2:123 | 2C | Men's Restroom |
| Duct | 2:125 | Roof | WestAHU |
| Duct | 2:126 | Roof | East AHU |
| Duct | 2:127 | 2C | Conference Rm |
| Duct | 2:208 | Bldo 45 | S. Mech. Room |
| Duct Test Switch | 2:146 | 2A | Roof |
| E Elev Redhat | 2:163 | Penthouse | E Elev Mech Rm |
| E Elev Shunt Trio | 2:164 | Penthouse | E Elev Mech Rm |
| Elev. Sm | 2:140 | Penthouse | Elev Machine Rm |
| P.I.V | 2:13 | G | Bldo 2 N.W P.I.V |
| P.I.V | 2:207 | Bldq 45 | West Of Bldq. 45 |
| Pad | 2:02 | GB | Pad 3 Trouble |
| Pad | 2:26 | 1D | Pad 3 Trouble |
| Pad | 2:40 | 1C | Elec Rm |
| Pad | 2:102 | 1B | Trouble |
| Pad | 2:134 | 2B | Pad-3 Trouble |
| Pad | 2:201 | Blda 45 | Pad-3 Trouble |
| PAD Trinner | 2:139 | 2C | Door Maos Elec Rm 2C14 |
| Prim Recall | 2:142 | WElev. | Pent West Elev. |
| Prim Recall | 2:144 | E Elev. | Pent East Elev. |
| Pull Station | 2:04 | GA | North Entrance |
| Pull Station | 2:07 | GA | North West Entrance |
| Pull Station | 2:08 | GB | Center Stairwell |
| Pull Station | 2:14 | GB | W Center Entrance |
| Pull Station | 2:18 | GC | West Entrance |
| Pull Station | 2:22 | GD | South Entrance |
| Pull Station | 2:25 | GD | East Stairwell |
| Pull Station | 2:27 | 1D | East Entrance |
| Pull Station | 2:28 | 1D | South Stairwell |
| Pull Station | 2:32 | G | Tunnel Entrance |
| Pull Station | 2:33 | G | North Stairwell |
| Pull Station | 2:37 | GC | N.W Door Research |
| Pull Station | 2:103 | 1A | North Stairwell |
| Pull Station | 2:106 | 1A | N.E Entrance |
| Pull Station | 2:109 | 1B | North Stairwell |
| Pull Station | 2:112 | 1C | South Stairwell |
| Pull Station | 2:118 | 2D | East Stairwell |
| Pull Station | 2:120 | 2A | North Stairwell |
| Pull Station | 2:131 | 2B | Center Stairwell |
| Pull Station | 2:138 | 2C | South Stairwell |
| Pull Station | 2:145 | Penthouse | Elev. Machine Rm |
| Pull Station | 2:158 | 2D | South Stairwell |
| Pull Station | 2:203 | Blda 45 | East Entrance |
| Pull Station | 2:204 | Blda 45 | West Entrance |
| Smoke Detector | 2:01 | GB | Pad3 Elec Room |
| Smoke Detector | 2:03 | GB | Elec Rm/ FACP |
| Smoke Detector | 2:11 | GB | West Elev Lobbv |
| Smoke Detector | 2:12 | GB | East Elev Lobby |
| Smoke Detector | 2:30 | G | Bsmt W Elev Lobby |
| Smoke Detector | 2:31 | G | Bsmt Elev. Lobby |
| Smoke Detector | 2:34 | 1D | Vl/ina D Pad 3 |
| Smoke Detector | 2:101 | 1B | 1st Floor Pad 3 |
| Smoke Detector | 2:110 | 1B | W Elev. Lobby |
| Smoke Detector | 2:111 | 1B | E Elev. Lobby |
| Smoke Detector | 2:115 | 2C | East Hallwav |
| Smoke Detector | 2:116 | 2D | East Hallway |
| Smoke Detector | 2:117 | 2D | East Hallway |
| Smoke Detector | 2:119 | 2D | Hallway |
| Smoke Detector | 2:128 | 2B | West Elev. Lobby |
| Smoke Detector | 2:129 | 2B | East Elev. Lobbv |
| Smoke Detector | 2:130 | 2B | Elec Rm Smoke Detector |
| Smoke Detector | 2:150 | 2D | S.E Hallway |
| Smoke Detector | 2:151 | 2D | S.E. Hallway |
| Smoke Detector | 2:152 | 2D | S.E Hallway |
| Smoke Detector | 2:153 | 2D | S.E Hallway |
| Smoke Detector | 2:154 | 2D | Hallway |
| Smoke Detector | 2:155 | 2D | Hallway |
| Smoke Detector | 2:156 | 2D | Hallway |
| Smoke Detector | 2:157 | 2D | Hallwav |
| Smoke Detector | 2:165 | Penthouse | W Elev Mech Rm |
| Smoke Detector | 2:166 | Penthouse | E Elev Mech Rm |
| Smoke Detector | 2:167 | E Elev Shaft | E Elev Shaft |
| Smoke Detector | 2:168 | Penthouse | W Elev Mech Rm |
| Smoke Detector | 2:169 | W Elev Shafi | W Elev Shafi |
| Smoke Detector | 2:202 | BldQ 45 | Telco Room |
| Tamper | 2:05 | GA | North Stairwell |
| Tamoer | 2:09 | GB | Center Stairwell |
| Tamoer | 2:16 | GC | Center Stairwell |
| Tamper | 2:19 | GD | S. W. P.I.V |
| Tamper | 2:23 | GD | South Stairwell |
| Tamoer | 2:29 | 10 | South Stairwell |
| Tamoer | 2:105 | 1A | North Stairwell |
| Tamper | 2:108 | 1B | Center Stairwell |
| Tamper | 2:114 | 1C | South Stairwell |
| Tamoer | 2:122 | 2A | North Stairwell |
| Tamoer | 2:124 | 2A | N Corridor |
| Tamper | 2:133 | 2B | Center Stairwell |
| Tamper | 2:136 | 2C | South Stairwell |
| Tamoer | 2:137 | 2C | South Corridor |
| Tamoer | 2:149 | 20 | Center Corridor |
| Tamoer | 2:160 | 20 | South Stairwell |
| W Elev Redhat | 2:161 | Penthouse | W Elev Mech Rm |
| W Elev Shunt Trip | 2:162 | Penthouse | W Elev Mech Rm |
| Waterflow | 2:05 | GA | North Stairwell |
| Waterflow | 2:09 | GB | Center Stairwell |
| Waterflow | 2:16 | GC | Center Stairwell |
| Water/low | 2:23 | GD | South Stairwell |
| Water/low | 2:29 | 10 | South Stairwell |
| Water/low | 2:104 | 1A | North Stairwell |
| Water/low | 2:107 | 1B | Center Stairwell |
| Waterflow | 2:113 | 1C | South Stairwell |
| Waterflow | 2:121 | 2A | North Stairwell |
| Water/low | 2:132 | 2B | Center Stairwell |
| Water/low | 2:135 | 2C | South Stairwell |
| Water/low | 2:159 | 20 | South Stairwell |
| Water/low/ Tamoer | 2:205 | Bldo45 | West Riser |
B4 Building 4 Inventory
| Type | Address | Zone | Location |
| Duct | 1:131 | WestAhu | WestAHU |
| Duct | 1:132 | EastAhu | EastAHU |
| Pad | 1:104 | 1B | Pad-3 Trouble |
| Pad/Door | 1:14 | BB | Pad-3 Trouble |
| Pull Station | 1:07 | BB00 | Corridor |
| Pull Station | 1:108 | 1A | Dav Room |
| Pull Station | 1:109 | 1A | Corridor |
| Pull Station | 1:110 | 1A | Corridor |
| Pull Station | 1:111 | 1A | Corridor |
| Pull Station | 1:112 | 1B | Corridor |
| Pull Station | 1:113 | 1B | West Lobbv |
| Pull Station | 1:114 | 1C | Corridor |
| Pull Station | 1:115 | 1C | Corridor |
| Roof | 1:141 | Prim Recall | Prim Recall |
| Roof | 1:142 | Sec Recall | Sec Recall |
| Smoke Detector | 1:01 | BB00A | Elev. Lobby |
| Smoke Detector | 1:02 | BB03B | Elec. Room |
| Smoke Detector | 1:101 | 1A | Corridor |
| Smoke Detector | 1:102 | 1B | Elev. Lobbv |
| Smoke Detector | 1:103 | 1C | Corridor |
| Smoke Detector | 1:121 | Roof | Elev. EauiP. Rm |
| Tamper | 1:15 | BB | Tamper 1-B,1-C |
| Tamper | 1:17 | BB | Tamper B-B |
| Tamper | 1:119 | 1A | Zone 1-A Valve |
| Waterflow | 1:15 | BB | Waterflow 1-B, 1-C |
| Waterflow | 1:17 | BB | Waterflow B-B |
| Waterflow | 1:19 | BB | Waterflow 1-A |
B5 Building 5 Inventory
| Type | Address | Zone | Location |
| Duct Detector | 1:142 | 1A | Kitchen AHU |
| Duct Detector | 1:144 | 1A | Kitchen AHU |
| Duct Test | 1:143 | 1A | Kitchen AHU |
| Duct Test | 1:145 | 1A | Kitchen AHU |
| Hood | 1:110 | 1A | Hood Svs Alarm |
| Hood | 1:110 | 1A | Hood Svs Trbl |
| Prim Recall | 1:106 | PH | Elev Mech Rm |
| Pull Station | 1:02 | BA | Stairwell/Tunnel |
| Pull Station | 1:03 | BA | Mech. Room |
| Pull Station | 1:26 | 1A | N Dinina Area |
| Pull Station | 1:101 | 1A | Stairwell |
| Pull Station | 1:121 | 1A | Stairwell |
| Pull Station | 1:122 | 1A | Stairwell |
| Pull Station | 1:123 | 1A | Stairwell |
| Pull Station | 1:124 | 1A | Receivina Dock |
| Pull Station | 1:125 | 1A | Storaae |
| Pull Station | 1:127 | 1A | Corridor |
| Sec Recall | 1:105 | PH | Elev Mech Rm |
| Smoke Detector | 1:04 | BA | Elev. Lobbv |
| Smoke Detector | 1:102 | 1A | Elev. Lobbv |
| Smoke Detector | 1:103 | 1A | FACP |
| Smoke Detector | 1:107 | PH | Elev Mech Rm |
| Tamper | 1:11 | BA | Bsm!Whse |
| Tamoer | 1:31 | BA | BsmtW Hall |
| Tamper | 1:33 | BA | PIV |
| Tamper | 1:34 | BA | Crawl Soace |
| Tamper | 1:133 | 1A | West Zone 1-A |
| Tamper | 1:135 | 1A | East Zone 1-A |
| Waterflow | 1:11 | BA | Bsm!Whse |
| Waterflow | 1:31 | BA | BsmtW Hall |
| Waterflow | 1:34 | BA | Crawl Soace |
| Waterflow | 1:36 | BA | Crawl Space |
| Waterflow | 1:133 | 1A | West Zone 1-A |
| Waterflow | 1:135 | 1A | East Zone 1-A |
B6 Building 6 Inventory
| Type | Address | Zone | Location |
| CO Detector | 1:19 | 1B | Boiler Control |
| CO Detector | 1:20 | 1B | Boiler Control |
| Combustible Sen. | 1:17 | 1B | Boiler Control |
| Combustible Sen. | 1:18 | 1B | Boiler Control |
| Duct Detector | 1:21 | PB | Penthouse |
| Fisher House Alarm | 2:10 | BB | Basement |
| Fisher House Trbl | 2:11 | BB | Basement |
| PIV | 2:21 | PIV | Bldg 6 PIV |
| Pull Station | 1:02 | 1B | Boiler Rm South |
| Pull Station | 1:03 | 1C | Elec Shop |
| Pull Station | 1:04 | 1C | Maint Shop Vest. |
| Pull Station | 1:05 | 1C | Machine Shop |
| Pull Station | 1:06 | 1C | Maint Wait area |
| Pull Station | 1:07 | 1C | Plumbing Shop |
| Pull Station | 1:08 | 1B | Boiler Rm East |
| Pull Station | 1:09 | 1A | Bldg 6 W Entry |
| PuII Station | 1:10 | 1A | E Vestibule |
| Pull Station | 1:11 | 1A | Mechanical Rm |
| Pull Station | 1:12 | 1A | File / Copv Rm |
| Pull Station | 1:13 | 1B | N Vestibule |
| Pull Station | 1:14 | 1B | Enaineerina |
| Pull Station | 2:16 | BB | Basement Stairs |
| Pull Station | 2:17 | BB | Basement Outside |
| Smoke Detector | 1:16 | 1B | Boiler Control |
| Smoke Detector | 2:01 | BB | Computer Room |
| Speaker Switch | 1:01 | 1B | Control Room |
| Tamper | 1:23 | 1A | Bldg 7 |
| Tamper | 2:19 | BB | Zone BB |
| Waterflow | 1:22 | 1A | Bldg 7 |
| Waterflow | 2:18 | BB | Zone BB |
| Waterflow | 2:20 | BB | Zone 1A |
B7 Building 7 Inventory
| Type | Address | Zone | Location |
| Duct | 1:34 | Basement | AHU#1 |
| Duct | 2:03 | 1C | AHU 7 Whse Sup |
| Duct | 2:04 | 1A | AHU Suoolv |
| Duct | 2:25 | 1A | AHU 401 |
| Duct | 2:26 | 1A | AHU 301 |
| Duct | 2:27 | 1A | AHU 501 |
| Duct | 2:28 | 1A | AHU 601 |
| Duct | 2:29 | 1A | AHU 701 |
| Duct | 2:35 | Roof | AHU 201 |
| Duct | 2:38 | 1C | AHU7 |
| Duct | 2:41 | 1A | AHU 1 |
| HVAC | 2:34 | HVAC /Mech | Mech |
| HVAC/Mech | 2:36 | HVAC / Mech | AHU7 |
| Pad 3 Trouble | 2:37 | 1A | Animal Research |
| Pull Station | 1:10 | 1B | Receivina (Soiled) |
| Pull Station | 1:12 | 1B | Distribution(138E) |
| Pull Station | 1:13 | 1B | Corridor |
| Pull Station | 1:35 | 1B | Corridor |
| Pull Station | 1:36 | 1B | Corridor |
| Pull Station | 2:05 | 1C | Rec Warehouse |
| Pull Station | 2:06 | 1C | Rec Warehouse |
| Pull Station | 2:07 | 1C | Warehouse Mech. |
| Pull Station | 2:08 | 1C | Will Call Office |
| Pull Station | 2:11 | 1C | Warehouse (04A) |
| Pull Station | 2:14 | 1A | Corridor |
| Pull Station | 2:15 | 1A | Corridor |
| Pull Station | 2:16 | 1A | Corridor |
| Pull Station | 2:17 | 1A | Corridor |
| Smoke Detector | 1:02 | 1B | Corridor |
| Smoke Detector | 2:46 | BC | FACP |
| Smoke Detector | 2:47 | 1A | Pad 3 Detector |
| Tamper | 2:19 | BC | Sida 7 PIV |
| Tamper | 2:20 | BC | Warehouse Valve |
| Tamper | 2:31 | 1A | Animal Research |
| Tamper | 2:33 | 1A | Zone 1-A |
| Tamper | 2:49 | BC | Boiler Room |
| Test Switch | 2:39 | 1C | AHU7 |
| Test Switch | 2:40 | 1C | AHU7 |
| Waterflow | 1:20 | 1C | Warehouse |
| Waterflow | 1:24 | 1B | Laundrv |
| Waterflow | 1:28 | 18 | Animal Research |
| Waterflow | 1:29 | 18 | Animal Research |
| Waterflow | 2:22 | 1C | Zone 1-C |
| Waterflow | 2:32 | 1A | Zone 1-A |
| Waterflow | 2:48 | BC | Boiler Room |
B8
| Building 8 Inventory | |||
| Type | Address | Zone | Location |
| Door Mao Rel | 1:118 | ALL | Buildina 8 |
| Duct | 1:122 | 1A | AHU-1 |
| Duct | 1:123 | 1A | AHU-1 |
| Hood Svstem | 1:125 | Kitchen | Kitchen |
| Hood Svstem | 1:126 | Kitchen | Kitchen |
| PAD Trouble | 1:17 | 1B | Electrical Room PAD |
| PIV | 1:107 | 1A | Sida 8 South PIV |
| PIV | 1:128 | GA | North PIV |
| Prim Recall | 1:19 | PA | Elev Eauip Rm |
| Pull Station | 1:03 | GA | Corridor West |
| Pull Station | 1:06 | GA | Gvm |
| Pull Station | 1:07 | GA | Multiouroose Room |
| Pull Station | 1:14 | 1B | East Exit |
| Pull Station | 1:15 | 1B | West Exit |
| Pull Station | 1:16 | 1B | North Exit |
| Pull Station | 1:103 | 1A | Corridor West |
| Pull Station | 1:104 | 1A | Pool |
| Pull Station | 1:105 | 1A | Pool |
| Pull Station | 1:108 | 1A | North |
| Pull Station | 1:109 | 1A | Multipurpose Rm |
| Pull Station | 1:110 | 1A | South |
| Pull Station | 1:111 | 1A | Kitchen |
| .Pull Station | 1:112 | 1A | East Door |
| Pull Station | 1:119 | 2A | Corridor |
| Pull Station | 1:120 | 2A | Corridor |
| Sec Recall | 1:20 | PA | Elev Eauip Rm |
| Smoke Detector | 1:01 | GA | Fire Panel |
| Smoke Detector | 1:02 | GA | Elev Lobbv |
| Smoke Detector | 1:05 | 1B | Mech Room |
| Smoke Detector | 1:09 | 1B | Electrical Room |
| Smoke Detector | 1:11 | 1B | IT Room |
| Smoke Detector | 1:12 | 1A | 151Fl Elev Lobby |
| Smoke Detector | 1:13 | 2A | 2nd FL Elev Lobbv |
| Smoke Detector | 1:18 | PA | Elev Equip Rm |
| Smoke Detector | 1:31 | GA | Offices |
| Smoke Detector | 1:102 | 1A | Corridor |
| Tamper | 1:04 | GA | G-AValve |
| Tamper | 1:08 | GA | G-a Valve |
| Tamper | 1:10 | GA | G-AValve |
| Tamper | 1:21 | GB | Zone 1-B |
| Tamper | 1:113 | 1A | 1A Valve |
| Tamper | 1:116 | 1A | 1-A Valve |
| TamPer | 1:129 | 2A | Zone 2-A |
| Waterflow | 1:04 | GA | North Grnd |
| Waterflow | 1:08 | GA | . Under Pool |
| Waterflow | 1:10 | GA | South Pool |
| Waterflow | 1:21 | 1B | Zone 1-B |
| Waterflow | 1:113 | 1A | 2A East |
| Waterflow | 1:116 | 1A | 2-A Kitchen |
| Waterflow | 1:129 | 2A | 2-A 2nd floor |
B9 Building 9 Inventory
| Type | Address | Zone | Location |
| Duct Detector | 2:06 | 2A | AHU-4 |
| Duct Detector | 2:07 | 2A | AHU-3 |
| Duct Detector | 2:08 | 2A | AHU-2 |
| Duct Detector | 2:09 | 2A | AHU-1 |
| Pull Station | 1:06 | 1A | South East Exit |
| Pull Station | 1:07 | 1A | South Stairwell |
| Pull Station | 1:09 | 1A | Auditorium |
| Pull Station | 1:10 | 1A | Auditorium |
| Pull Station | 1:11 | 1A | North Entry |
| Pull Station | 1:12 | 1A | West Exit |
| Pull Station | 2:05 | 1A | West Corridor |
| Pull Station | 2:20 | 1A | Auditorium/ Classroom |
| Smoke Detector | 1:04 | 2A | Storeroom |
| Smoke Detector | 2:01 | 2A | Video Store Rm |
| Smoke Detector | 2:02 | 1A | Rec Rm |
| Smoke Detector | 2:03 | 1A | Rec Rm |
| Smoke Detector | 2:04 | 1A | Rec Rm |
| Smoke Detector | 2:10 | 1A | Fire Panel |
| Tamper | 2:15 | BA | Backflow Crawl |
| Tamper | 2:16 | BA | Backflow Crawl |
| Tamper | 2:18 | BA | Bldq9 PIV (Crawl Space) |
| Waterflow | 2:13 | BA | Crawl Space |
| Waterflow | 2:14 | BA | Crawl Space |
B13 Building 13 Inventory
| Type | Address | Zone | Location |
| Pull Station | 1:02 | BA | Bsmt Stairs |
| Pull Station | 1:06 | 2A | Elev Lobbv |
| Pull Station | 1:14 | 1A | Ground Floor North |
| PuII Station | 1:15 | 1A | Ground Floor South |
| PuII Station | 1:16 | 1A | Ground Entrv Door |
| Smoke Detector | 1:01 | BA | Fire Panel |
| Smoke Detector | 1:07 | 1A | Ground Floor |
| Smoke Detector | 1:08 | 1A | Ground Floor |
| Smoke Detector | 1:09 | 1A | Ground Floor |
| Smoke Detector | 1:10 | 1A | Ground Floor |
| Smoke Detector | 1:11 | 1A | Elev Equip Rm |
| Smoke Detector | 1:12 | 1A | Ground Floor |
| Smoke Detector | 1:13 | 1A | Ground Floor |
| Smoke Detector | 1:101 | 2A | 2nd Floor |
| Smoke Detector | 1:102 | 2A | 2nd Floor |
| Smoke Detector | 1:103 | 2A | 2nd Floor |
| Smoke Detector | 1:104 | 2A | 2nd Floor |
| Smoke Detector | 1:105 | 2A | 2nd Floor |
| Tamper | 1:03 | BA | Zone B-A |
| Tamoer | 1:17 | 1A | Zone 1-A |
| Tamper | 1:19 | BA | Bldq 13 |
| Tamoer | 1:107 | 2A | 2-A Valve |
| Waterflow | 1:03 | BA | Zone B-A |
| Waterflow | 1:17 | 1A | Zone 1-A |
| Waterflow | 1:19 | BA | Blda 13 |
| Waterflow | 1:107 | 2A | Zone 2-A |
B16 Building 16 Inventory
| Type | Address | Zone | Location |
| Damoers | 1:09 | 1A | L1 Damoers |
| Damoers | 3:13 | GA | Basement Damners |
| Door Holders | 2:07 | 2A | L2 Elev Doors |
| Duct | 1:10 | 1A | Med Pren |
| Duct | 1:12 | 1A | L1 Tele Health Duct |
| Duct | 1:15 | 1A | L1 Men's Restroom Duct |
| Duct | 1:17 | 1A | L1 Mech Shaft Duct |
| Duct | 1:18 | 1A | L1 Storaae |
| Duct | 2:11 | 2A | Rm 2A44 |
| Duct | 2:13 | 2A | L2 Rm 2A30 |
| Duct | 2:15 | 2A | L2 Rm 2A30 |
| Duct | 2:19 | 2A | L2 Psvchiatric Restroom |
| Duct | 2:21 | 2A | L2 Men's Restroom |
| Duct | 3:22 | GA | Basement Data Rm |
| Duct | 3:23 | GA-C | Basement Hall |
| Duct | 3:25 | GA-E | Basement Hall |
| Duct Detector | 3:27 | GA | Basement Shell |
| Duct Detector | 3:28 | GA | Basement Shell |
| Duct Detector | 3:29 | GA | Basement Shell |
| Duct Detector | 3:30 | GA | Basement Shell |
| Duct Detector | 3:31 | GA | Basement Shell |
| Duct Test | 2:12 | 2A | Switch 2:11 |
| Duct Test | 2:14 | 2A | Switch 2:13 |
| Duct Test | 2:16 | 2A | Switch 2:15 |
| Duct Test | 2:20 | 2A | Switch 2:19 |
| Duct Test | 2:22 | 2A | Switch 2:21 |
| Duct Test | 3:24 | GA | Switch |
| Duct Test | 3:26 | GA | Switch |
| Elev Door | 3:15 | GA | Holders |
| Fan Shutdown | 3:04 | GA | GA63A |
| Fan Shutdown | 3:05 | GA | GA63 |
| Fan Shutdown | 3:06 | GA | GA63 |
| Heat Detector | 3:37 | GA | Elev Equip Rm |
| Heat Detector | 3:38 | GA | Elev Pit Heat |
| Pad 3 Trouble | 2:03 | 2A | 2nd Fir PAD |
| Pad-3 | 3:01 | GA | Trouble |
| Prim Recall | 3:16 | GA | Elev Equip Rm |
| Pull Station | 1:04 | 1A | L1 Exit |
| Pull Station | 1:08 | 1A | L1 Waitinq Area |
| Pull Station | 1:21 | 1A | Exit |
| Pull Station | 2:05 | 2A | L2 Exit |
| Pull Station | 2:06 | 2A | L2 Exit |
| Pull Station | 3:11 | GA | GA-E |
| Pull Station | 3:12 | GA | GA-C Exit |
| Pull Station | 3:39 | GA | Craft I Kitchen |
| Relay | 1:05 | 1A | Fire Bell Relay |
| Relay | 1:06 | 1A | L1 Elev Door Holder |
| Relay | 3:18 | GA | Elev Hat |
| Relav | 3:19 | GA | Shunt Trio |
| Sec Recall | 3:17 | GA | Elev Equip Rm |
| Smoke Damoer | 2:04 | 2A | L2 Smoke Damoer |
| Smoke Detector | 1:02 | 1A | L1 Elec Rm |
| Smoke Detector | 1:03 | 1A | L1 Data Rm |
| Smoke Detector | 1:07 | 1A | L1 Elev Lobby |
| Smoke Detector | 1:14 | 1A | L1 West Janitors Closet |
| Smoke Detector | 1:20 | 1A | L1 StoraQe Rm |
| Smoke Detector | 2:01 | 2A | L2 Data Rm |
| Smoke Detector | 2:02 | 2A | L2 Elec Rm |
| Smoke Detector | 2:08 | 2A | L2 Elev Lobby |
| Smoke Detector | 2:09 | 2A | L2 East Stairs |
| Smoke Detector | 2:10 | 2A | L2 West Stairs |
| Smoke Detector | 2:17 | 2A | L2 West Closet |
| Smoke Detector | 2:18 | 2A | L2 Rm 2A42 |
| Smoke Detector | 2:49 | 2A | Elev Shaft |
| Smoke Detector | 3:02 | GA | Elec Room |
| Smoke Detector | 3:03 | GA | Data Room |
| Smoke Detector | 3:14 | GA | Basement Closet |
| Smoke Detector | 3:20 | GA | Elev Eauio Rm |
| Smoke Detector | 3:21 | GA | Elev Lobby |
| Smoke Detector | 3:32 | GA | Basement Shell |
| Smoke Detector | 3:33 | GA | Basement Shell |
| Smoke Detector | 3:34 | GA | Basement Shell |
| Smoke Detector | 3:35 | GA | Basement Shell |
| Tamper | 3:08 | GA | Main Riser |
| Tamper | 3:09 | GA | Main Riser |
| Tamper | 3:10 | GA | Main Riser |
| Tamoer | 3:36 | GA | PIV |
| Test Switch | 1:11 | 1A | 1:10 test switch |
| Test Switch | 1:13 | 1A | 1:12 Test switch |
| Test Switch | 1:16 | 1A | 1:15 Test Switch |
| Test Switch | 1:19 | 1A | 1:18 Test Switch |
| Trouble | 1:01 | 1A | Horn Strobe |
| Waterflow | 3:07 | GA | Main Riser |
B18 Building 18 Inventory
| Type | Address | Zone | Location |
| Pull Station | 1:02 | 1A | East Pull |
| Pull Station | 1:03 | 1A | West Pull |
| Smoke Detector | 1:01 | 1A | FACP |
| Waterflow/ Tamper | 1:04 | 1A | Main Riser |
B32 Building 32 Inventory
| Type | Address | Zone | Location |
| CO Detector | 2:9 | 1A | Mech Rm |
| CO Detector | 2:10 | 1A | East Hall |
| CO Detector | 2:11 | 1A | Laundry Rm |
| CO Detector | 2:12 | 2A | Upstairs Hall |
| CO Detector | 2:13 | 1A | West Hall |
| Duct | 2:29 | 1A | AHU |
| Duct Detector | 2:54 | 1A | West Duct |
| Duct Detector | 2:68 | 2A | Attic |
| Elev Hat Relay | 2:17 | 1A | Elev Mech Rm |
| Elev Shunt Trip | 2:16 | 1A | Elev Mech Rm |
| Fire Curtain | 2:19 | 1A | Main Lobby |
| Heat Detector | 2:7 | 1A | Elev Equip Rm |
| Heat Detector | 2:22 | 1A | Laundry Rm |
| Heat Detector | 2:23 | 1A | Kitchen |
| Prim Recall | 2:14 | 1A | Elev Mech Rm |
| Pull Station | 2:1 | 1A | Kitchen |
| Pull Station | 2:24 | 1A | Rear Hall |
| Pull Station | 2:36 | 1A | NE Hall Front |
| Pull Station | 2:44 | 1A | Main Entry |
| Pull Station | 2:48 | 1A | NW Hall 125 Front |
| Pull Station | 2:62 | 1A | SW Hall 125 Rear |
| Pull Station | 2:66 | 2A | Rear Upstairs |
| Pull Station | 2:71 | 2A | Upstairs Hall |
| Pull Station | 2:74 | 2A | Upstairs Elev |
| Pull Station | 2:76 | 2A | Upstairs Front |
| Sec Recall | 2:15 | 1A | Elev Mech Rm |
| Smoke Dampers | 2:18 | 1A | Above Ceilinqs |
| Smoke Detector | 2:2 | 1A | Family Rm #1 |
| Smoke Detector | 2:3 | 1A | Family Rm #2 |
| Smoke Detector | 2:4 | 1A | Mech Rm |
| Smoke Detector | 2:8 | 1A | Elev Equipment Rm |
| Smoke Detector | 2:21 | 1A | Storaqe Rm |
| Smoke Detector | 2:25 | 1A | Rear Hall |
| Smoke Detector | 2:26 | 1A | Room 106 |
| Smoke Detector | 2:27 | 1A | Room 105 |
| Smoke Detector | 2:28 | 1A | Room 104 |
| Smoke Detector | 2:31 | 1A | Room 103 |
| Smoke Detector | 2:32 | 1A | East Hall |
| Smoke Detector | 2:33 | 1A | Room 102 |
| Smoke Detector | 2:34 | 1A | East Hall 112A |
| Smoke Detector | 2:35 | 1A | Room 101 |
| Smoke Detector | 2:37 | 1A | NE Front Hall 112 |
| Smoke Detector | 2:38 | 1A | East Mid Hall |
| Smoke Detector | 2:39 | 1A | Hall 103 by Kitchen |
| Smoke Detector | 2:40 | 1A | Main Fir Elev Lobby |
| Smoke Detector | 2:41 | 1A | Dining Rm Rear |
| Smoke Detector | 2:42 | 1A | Dining Rm Front |
| Smoke Detector | 2:43 | 1A | Main Entry Foyer |
| Smoke Detector | 2:45 | 1A | Living Rm Front |
| Smoke Detector | 2:46 | 1A | Living Rm Rear |
| Smoke Detector | 2:47 | 1A | Hall By Powder |
| Smoke Detector | 2:49 | 1A | NW Hall 125 Front |
| Smoke Detector | 2:50 | 1A | NW Hall 125 Middle |
| Smoke Detector | 2:51 | 1A | Room 112 |
| Smoke Detector | 2:52 | 1A | Room 111 |
| Smoke Detector | 2:53 | 1A | Room 110 |
| Smoke Detector | 2:56 | 1A | Room 109 |
| Smoke Detector | 2:57 | 1A | West Hall 125 Far |
| Smoke Detector | 2:58 | 1A | Room 108 |
| Smoke Detector | 2:59 | 1A | West Hall 125A Near |
| Smoke Detector | 2:60 | 1A | Room 107 |
| Smoke Detector | 2:61 | 1A | SW Hall 125 Rear |
| Smoke Detector | 2:63 | 1A | Office |
| Smoke Detector | 2:64 | 2A | Room 206 |
| Smoke Detector | 2:65 | 2A | Room 2 Hall 05 |
| Smoke Detector | 2:67 | 2A | Hall Up Hall Rear |
| Smoke Detector | 2:70 | 2A | Upstairs Storage |
| Smoke Detector | 2:72 | 2A | Room 207 |
| Smoke Detector | 2:73 | 2A | Stairwell |
| Smoke Detector | 2:75 | 2A | Upstairs Elev Lobby |
| Smoke Detector | 2:77 | 2A | Front Upstairs Hall |
| Smoke Detector | 2:78 | 2A | Room 208 |
| Smoke Detector | 2:79 | 2A | Room 201 |
| Smoke Detector | 2:80 | 2A | Room 202 |
| Smoke Detector | 2:81 | 2A | Room 203 |
| Smoke Detector | 2:82 | 2A | Room 204 |
| Tamper | 2:6 | 1A | Main Tamper |
| Test Switch | 2:30 | 1A | AHU |
| Test Switch | 2:55 | 1A | West Duct |
| Test Switch | 2:69 | 2A | AHU |
| Waterflow | 2:5 | 1A | Main Waterflow |
B38 Building 38 Inventory
| Type | Address | Zone | Location |
| Pull Station | 1:02 | 1A | Office Exit |
| Pull Station | 1:03 | 1A | Machine Shop |
| Pull Station | 1:04 | 1A | Carpenter Shop |
| Pull Station | 1:05 | 1A | Storage Room |
| Smoke Detector | 1:01 | 1A | Fire Panel |
| Tamper | 1:07 | 1A | Machine Shop |
| Waterflow | 1:06 | 1A | Machine Shop |
B39 Building 39 Inventory
| Type | Address | Zone | Location |
| Finaer Heat Detector | Zone | 1A | Blda 39 |
| Pull Station | Zone | 1A | Blda 39 |
| Pull Station | Zone | 1A | Blda 39 |
B40 Building 40 Inventory
| Type | Address | Zone | Location |
| Finqer Heat Detector | Zone | 1A | Bldq 40 |
| Finqer Heat Detector | Zone | 1A | Bldq 40 |
| Pull Station | Zone | 1A | Bldq 40 |
| Pull Station | Zone | 1A | Bldq 40 |
B42 Building 42 Inventory
| Type | Address | Zone | Location |
| Finaer Heat Detector | Zone | 1A | Blda 42 |
| Finaer Heat Detector | Zone | 1A | Blda 42 |
| Pull Station | Zone | 1A | Blda 42 |
| Pull Station | Zone | 1A | Blda 42 |
| Pull Station | Zone | 1A | Blda 42 |
| Smoke Detector | Zone | 1A | Blda 42 |
| Smoke Detector | Zone | 1A | Blda 42 |
| Smoke Detector | Zone | 1A | Blda 42 |
Compatibility Report
| Compatibility Report for Copy of SLC VAMC Fire Alarm Inventory 2020_0915.xls |
| Run on 9/16/2020 7:44 |
If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available.
Minor loss of fidelity # of occurrences Version
Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 43 Excel 97-2003