36C25919R0113-0006003.pdf
PDF 2 MB Posted
- Solicitation number
- 36C25919R0113
About this file
36C25919R0113 0006 18-235_Addm1_combined.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25919R0113-0006001.pdf | ||
| 36C25919R0113-0006002.pdf | ||
| 36C25919R0113-0006004.pdf | ||
| 36C25919R0113-0006000.docx | DOCX document | |
| 36C25919R0113-0005000.docx | DOCX document | |
| 36C25919R0113-0004000.docx | DOCX document | |
| 36C25919R0113-0003000.docx | DOCX document | |
| 36C25919R0113-0002001.pdf | ||
| 36C25919R0113-0002000.docx | DOCX document | |
| 36C25919R0113-0001002.pdf | ||
| 36C25919R0113-0001000.docx | DOCX document | |
| 36C25919R0113-0001001.pdf | ||
| 36C25919R0113-002.pdf | ||
| 36C25919R0113-003.pdf | ||
| 36C25919R0113-004.docx | DOCX document | |
| 36C25919R0113-001.docx | DOCX document | |
| 36C25919R0113-005.docx | DOCX document | |
| 36C25919R0113-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1010B
ANTE
ROOM
STERILE
PREP AREA
CHEMO
PREP AREA
1010A
H
T H
T
HAC
EXISTING
TOILET
E. AFMS
E. AFMS
EXISTING 6x14
SD1-380
TB-1
TB-3
TB-2
SD1-400
SD1-270
T
H
SIDE ACCESS
HEPA FILTER
HOUSING FF-1
EXISTING
ABANDONED
EXISTING
AHU-3
4"Ø
1010B
ANTE
ROOM
HAC
EXISTING
TOILET
STERILE
PREP AREA
CHEMO
PREP AREA
1010A
MAINTAIN 6'-0"
CLEAR.
NEW EXHAUST
FAN 1-EF-10
FLEXIBLE
CONNECTION
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
SHEET KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019
GRAND JUNCTION VA MEDICAL
CENTER - UPGRADE HAZARDOUS
DRUG WORKSPACE
575-18-110
VA WESTERN COLORADO
HEALTH CARE SYSTEM
2121 NORTH AVENUE
GRAND JUNCTION, CO 81501
18-235
100% BID DOCUMENTS
FULLY SPRINKLERED
Structural Engineer:
N
AREA OF
WORK
KEY PLAN
ELECTRICAL
CLOSET
P
M
M-101
PARCM
MECHANICAL PLAN
FULLY SPRINKLERED
Scale: 3/8" = 1'-0"
FIRST FLOOR MECHANICAL PLAN
1. MAINTAIN THE PHARMACY AREA OUTSIDE THE
PROJECT WORK BOUNDARY BETWEEN 68°F AND
77°F. PROVIDE TEMPORARY COOLING AND
HEATING IF NEEDED DURING OUTAGES.
0 1 2 4
NORTH
PLAN
Scale: 1/4" = 1'-0"
PARTIAL ROOF MECHANICAL PLAN
1. CONNECT NEW 18x6 TO EXISTING DUCT DROP.
BALANCE EXISTING WALL GRILLE TO 400 CFM.
EXTEND AND CONNECT 18x6 TO EXISTING 26x14
RETURN DUCT.
2. 10"Ø STAINLESS STEEL EXHAUST DUCT FROM
CHASE AND TRANSITION TO HOOD CONNECTION.
BALANCE HOOD EXHAUST TO 500 CFM WITH
DAMPER IN CHASE.
3. 16x8 STAINLESS STEEL EXHAUST DOWN IN HAC
TO EG1-700 AT 8" A.F.F. IN ANTE ROOM 1010.
SEAL DUCT AIRTIGHT AT WALL PENETRATION TO
ANTEROOM.
4. 8x8 STAINLESS STEEL EXHAUST DUCT DOWN IN
CHASE AND TRANSITION TO A EG2-400 AT 8"
A.F.F. INTO CHEMO PREP AREA 1010A. SEAL
DUCT AIR TIGHT AT WALL PENETRATION TO
CHEMO PREP AREA.
5. INSTALL ROOM TEMPERATURE AND HUMIDITY
SENSOR ON WALL AT 48" ABOVE FINISHED
FLOOR.
6. MOUNT ROOM PRESSURE MONITOR ON WALL AT
48" ABOVE FINISHED FLOOR IN ACCORDANCE
WITH MANUFACTURERS INSTRUCTIONS. EXTEND
ROOM PRESSURE BACNET ANALOG SIGNAL TO
BAS.
7. NEW EXHAUST FAN 1-EF-10 TO REPLACE
EXISTING FAN. PROVIDE TRANSITION FROM
DUCT TO FAN INLET. PROVIDE FLEX
CONNECTION.
8. EXISTING TO REMAIN.
9. ADJUST SUPPLY FAN SPEED TO MAINTAIN SPACE
AIRFLOWS. MEASURE PRE-DEMOLITION PLUS
THE CFM ADDED AS NOTED ON THE DRAWINGS.
SEE MD101 ADJUST SUPPLY FAN TO 75HZ
MAXIMUM. NOTIFY THE COR IF AIRFLOW CANNOT
BE OBTAINED.
10. 4"Ø DUCT FROM EXISTING GENERAL EXHAUST
DUCT TO HAC CABINET OUTLET PROVIDE DUCT
TRANSITIONS AS NEEDED. BALANCE TO 30 CFM.
11. CAP DUCT AND SEAL AIR TIGHT.
12. INSTALL NEW STAINLESS STEEL EXHAUST DUCT
IN LOCATION OF EXISTING.
13. EXISTING SUPPLY DUCT TO REMAIN.
14. AT ABANDONED FAN ROOF PENETRATIONS,
PATCH EXISTING ROOF PER THE ROOFING
MANUFACTURER'S RECOMMENDATIONS AND
INSTRUCTIONS.
0 21 4
NORTH
PLAN
1 PRE-BID CHANGES 5-16-2019
DocuSign Envelope ID: 24AD58DA-A5BD-489E-9D86-99A960180B24
5/31/2019
EXISTING
RETURN
DUCT
EXISTING SUPPLY
DISCHARGE PLENUM
EXISTING AHU-3
FLOOR
EXISTING RETURN DUCT
NEW 12"Ø STAINBLESS STEEL
EXHAUST DUCT FROM PHARMACY
IN PLACE OF EXISTING
EXISTING 14"Ø SUPPLY DUCT
EXISTING SUPPLY DUCT
CONCRETE DECK
EX. AHU-3 SUPPLY PLENUM
EX. 36"Ø SUPPLY DUCT
EX. 8"Ø, EXHAUST
EX. RETURN DUCT
FLOOR
FF-1
EX. RETURN
FAN
BEYOND
WALL
EX. AFMS IN RETURN DUCT
12" Ø S.S. EXHAUST DUCT
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019
GRAND JUNCTION VA MEDICAL
CENTER - UPGRADE HAZARDOUS
DRUG WORKSPACE
575-18-110
VA WESTERN COLORADO
HEALTH CARE SYSTEM
2121 NORTH AVENUE
GRAND JUNCTION, CO 81501
18-235
100% BID DOCUMENTS
FULLY SPRINKLERED
Structural Engineer:
P
M
M-301
PARCM
MECHANICAL SCHEDULES AND DETAILS
FULLY SPRINKLERED
Scale: 1/2" = 1'-0"
ELEVATION AT EXISTING AHU-3 DISCHARGE PLENUM (SEE M-101) 0 1 2 4
NORTH
PLAN
0 1 2 4
NORTH
PLAN
0 1 2 4
NORTH
PLAN
Scale: 1/2" = 1'-0"
SECTION 2 (SEE M-101)
1 PRE-BID CHANGES 5-16-2019
STERILE PREP AREA
1010B
CHEMO PREP AREA
1010A
ANTEROOM
PRESSURIZATION:
SA:
OA:
EA:
RA:
FLOW DIFF:100 CFM
POSITIVE
800 CFM
400 CFM
700 CFM
0 CFMPRESSURIZATION:
SA:
OA:
EA:
RA:
FLOW DIFF:140 CFM
POSITIVE
540 CFM
180 CFM
0 CFM
400 CFM
PRESSURIZATION:
SA:
OA:
EA:
RA:
FLOW DIFF:-140 CFM
NEGATIVE
760 CFM
380 CFM
900 CFM
0 CFM
LIGHTNING PROTECTION ROD
7'-0" MINIMUM
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019
GRAND JUNCTION VA MEDICAL
CENTER - UPGRADE HAZARDOUS
DRUG WORKSPACE
575-18-110
VA WESTERN COLORADO
HEALTH CARE SYSTEM
2121 NORTH AVENUE
GRAND JUNCTION, CO 81501
18-235
100% BID DOCUMENTS
FULLY SPRINKLERED
Structural Engineer:
P
M
M-601
PARCM
MECHANICAL SCHEDULES AND DETAILS
FULLY SPRINKLERED
N
SCALE: 1/4" = 1'-0"
ROOM PRESSURIZATION PLAN
N.T.S.
REHEAT COIL PIPING DETAIL
SCALE:
Scale: 1/2" = 1'-0"
ROOF EXHAUST FAN DETAIL
1 ADDENDUM 1 5-8-2019
2 PREBID CHANGES 5-16-2019
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
A
B C
D E
21 4 5 6 7
SHEET NOTES:
SHEET KEY NOTES:
321 4 5 6 7
A B
C D
E
Dwg. of
LocationLocation
PROJECT MANAGER:CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.
05/30/2019
575-18-110
VA WESTERN COLORADO
HEALTH CARE SYSTEM
2121 NORTH AVENUE
GRAND JUNCTION, CO 81501
18-235
100% BID DOCUMENTS
FULLY SPRINKLERED
Structural Engineer:
N
AREA OF
WORK
ELECTRICAL
CLOSET
RCMRCM
FP101
0 2 4 8
NORTH
PLAN