36C25919R0113-0006002.pdf

PDF 6 MB Posted

Attached to
Demolish and remodel hazardous drug compounding area (VA-19-00046876)
Solicitation number
36C25919R0113
Issued by

About this file

36C25919R0113 0006 18-235_ADDM1_ELEC.pdf

View the file

Other files

File Type Posted
36C25919R0113-0006001.pdf PDF
36C25919R0113-0006003.pdf PDF
36C25919R0113-0006004.pdf PDF
36C25919R0113-0006000.docx DOCX document
36C25919R0113-0005000.docx DOCX document
36C25919R0113-0004000.docx DOCX document
36C25919R0113-0003000.docx DOCX document
36C25919R0113-0002001.pdf PDF
36C25919R0113-0002000.docx DOCX document
36C25919R0113-0001002.pdf PDF
36C25919R0113-0001000.docx DOCX document
36C25919R0113-0001001.pdf PDF
36C25919R0113-002.pdf PDF
36C25919R0113-003.pdf PDF
36C25919R0113-004.docx DOCX document
36C25919R0113-001.docx DOCX document
36C25919R0113-005.docx DOCX document
36C25919R0113-000.docx DOCX document
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIAL PURPOSE RECEPTACLE - FLUSH FLOOR MOUNTED

SPECIAL PURPOSE RECEPTACLE - CEILING MOUNTED

SPECIAL PURPOSE RECEPTACLE - MOUNTED 18" AFF

QUADRUPLEX RECEPTACLE - FLUSH FLOOR MOUNTED

DUPLEX RECEPTACLE - FLUSH FLOOR MOUNTED

SINGLE RECEPTACLE - MOUNTED 18" AFF

QUADRUPLEX RECEPTACLE - MOUNTED 18" AFF

UTILITY KILOWATT-HOUR METER

DUPLEX RECEPTACLE - EMERGENCY POWER - MOUNTED 18" AFF

DUPLEX RECEPTACLE - CEILING MOUNTED

DUPLEX RECEPTACLE - SPLIT WIRED - MOUNTED 18" AFF

DUPLEX RECEPTACLE - MOUNTED 6" ABOVE COUNTER

MAGNETIC STARTER

SAFETY SWITCH - FUSIBLE

SAFETY SWITCH - NON-FUSIBLE

EQUIPMENT - MOTOR

BRANCH CIRCUIT PANELBOARD - FLUSH MOUNTED

DISTRIBUTION PANELBOARD OR SWITCHBOARD

MOTOR CONTROL CENTER

BRANCH CIRCUIT PANELBOARD - SURFACE MOUNTED

CONTROL PANEL

TRANSFORMER

POWER SYMBOLS

AUTOMATIC TRANSFER SWITCH

METER

CIRCUIT BREAKER

GROUND

ONE-LINE DIAGRAM SYMBOLS

GENERATOR

DELTA-WYE TRANSFORMER

SWITCH

SERVICE DROP

CONDUIT - CAPPED

CABLE TRAY

SEALING FITTING

EXPANSION FITTING

CONDUIT FITTING (CONDULET)

JUNCTION BOX

CONDUIT - FLEXIBLE

CONDUIT - CONTINUED

CONDUIT - CONCEALED BELOW

SLAB OR GRADE

CONDUIT - UP AND DOWN

(CHANGE IN ELEVATION)

CONDUIT - TURNING UP

CONDUIT - EXPOSED

CONDUIT - CONCEALED IN

SUSPENDED CEILING OR WALL

CONDUIT - TURNING DOWN

REVISION CALL-OUT

ROOM NUMBER

FEEDER CALL-OUT

KEYED NOTE

GENERAL SYMBOLS

JUNCTION BOX - EMERGENCY POWER

SHEET KEY NOTE

WIRING AND CONDUITS

NEW EQUIPMENT (TYPICAL)

EXISTING EQUIPMENT (TYPICAL)

DEMOLITION EQUIPMENT (TYPICAL)

WALL MOUNT BRACKET (TYPICAL)

T-1

45 KVA 3Ø

208Y/120VAC

# AF

# AT

# A

# A

G

ST

SPD

VFD

GROUND FAULT

PROTECTED BREAKER

SHUNT TRIP BREAKER

CONTACTOR

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

DRAWOUT CIRCUIT BREAKER

# AF

# AT

FUSE

PANELBOARD

SURGE PROTECTION DEVICE

THERMAL OVERLOAD

VARIABLE FREQUENCY DRIVE

K

KIRK KEY INTERLOCK

DPM

DIGITAL POWER METER

QUADRUPLEX RECEPTACLE - MOUNTED 6" ABOVE

COUNTER

Room name

101A

J

J

M

G

# A

# POLES

PANEL

M

F

VFD

T

POLE MOUNTED TRANSFORMER

T

J

DUPLEX RECEPTACLE (NEMA 5-20R) - MOUNTED 18" AFF

GFI GROUND FAULT CIRCUIT INTERRUPTER

SS SURGE SUPPRESSOR (ISOLATED GROUND

TYPE)

WP WEATHERPROOF

H HOSPITAL GRADE

TP TAMPER PROOF

DED

DEDICATED

FLOOR BOX - SEE SPECS OR KEYED NOTES ON

PLAN FOR DETAILS

COMBINATION STARTER

VFD VARIABLE FREQUENCY DRIVE

AC

AC

GROUND BAR

100A4G

# KVA/KW

480Y/277V, 3Ø, 4W

49 ELECTRONIC OVERLOAD

LIGHTING SYMBOLS

12" X 48" SURFACE LED LIGHT FIXTURE

DUPLEX RECEPTACLE FOR DEDICATED LOAD

OC

CEILING MOUNTED OCCUPANCY SENSOR

L

L

ELECTRICAL ABBREVIATIONS LIST

SS STAINLESS STEEL

SSW SELECTOR SWITCH

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TC TIMECLOCK

TEL TELEPHONE

TEL/DATA TELEPHONE/DATA

TERM TERMINAL

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL

CABINET

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORY

UT UNDERGROUND TELEPHONE

UTP UNSHIELDED TWISTED PAIR

UTIL UTILITY

UV UNIT VENTILATOR OR

ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

ANGLE

@ AT

DELTA

' FEET

" INCHES

# NUMBER

Φ PHASE

C CENTER LINE

P PLATE

MTS MANUAL TRANSFER SWITCH

MTR MOTOR, MOTORIZED

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY DISCONNECT

SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OL OVERLOAD

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT

UNIT

PCB POLYCHLORINATED BYPHENYL

PC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

POE POWER-OVER-ETHERNET

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QTY QUANTITY

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SF SQUARE FEET/FOOT

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

SR SURFACE RACEWAY

1P 1 POLE (2P, 3P, 4P, ETC.)

1PH 1 PHASE

2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)

W2 TWO-WIRE (3W, 4W, ETC.)

3PH 3 PHASE

A AMPERE

AAP ALARM ANNUNCIATOR PANEL

AC ABOVE COUNTER

AIR CONDITIONER

ALTERNATING CURRENT

ACC ACCESSIBLE

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

A/E ARCHITECT/ENGINEER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT (KILOAMPS)

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

APPROX APPROXIMATELY

ARCH ARCHITECT, ARCHITECTURAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISHED FLOOR

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATED

CAP CAPACITY

CAT CATALOG, CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR-FURNISHED

CKT CIRCUIT

CLG CEILING

COAX COAXIAL CABLE

COMM COMMUNICATION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONTR CONTRACTOR

COORDCOORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CTR CENTER

CU COPPER

CU FT CUBIC FEET

dB DECIBEL

DB DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLISH/DEMOLITION

DEPT DEPARTMENT

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

EG EQUIPMENT GROUND

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EPO EMERGENCY POWER OFF

EQUIP EQUIPMENT

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WALL HEATER

ELECTRIC WATER HEATER

EX EXISTING

EXP EXPLOSION PROOF

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT SWITCH

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

GRS GALVANIZED RIGID STEEL (CONDUIT)

GYP BDGYPSUM BOARD

HID HIGH-INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

IES ILLUMINATION ENGINEERING SOCIETY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

I/W INTERLOCK WITH

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LED LIGHT-EMITTING DIODE

LF LINEAR FEET/FOOT

LM LUMEN

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

METAL-CLAD (CONDUIT)

MCA MINIMUM CIRCUIT AMPACITY

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT SWITCH

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MOA MULTIOUTLET ASSEMBLY

MSBD MAIN SWITCHBOARD

MT MOUNT

A1 b

E1 c d

T1

'LPN'

ELECTRICAL SYMBOL NOTES

THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER

CASE LETTER AND NUMBER.

THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.

EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.

EXIT SIGNS: STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING

MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES

DIRECTIONAL ARROW ON ILLUMINATED FACE(S).

DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER

FOLLOWING THE UPPER CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR

THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER DESCRIPTION AND

REQUIREMENTS.

PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING

SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR

DESIGNATION CODES.

SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE

NUMBER INDICATED IN THE HEXAGON.

HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT

DESIGNATION ARE SHOWN ADJACENT TO THE HOME RUN ARROW.

CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL

SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.

SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE

A UNIT TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.

'LPN'-1,3,5

EXAMPLE 1: WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE

AND DIRECTIONAL ARROW.

EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE

FACE AND DIRECTIONAL ARROWS.

E2

EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS

CONTROLLED BY SWITCH 'c'.

EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING

FIXTURES INDICATED BY 'd'.

EXAMPLE: TRANSFORMER TYPE 'T1'.

EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.

DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE

NOTE NUMBER INDICATED IN THE SQUARE.

GENERAL ELECTRICAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN

ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED

PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND

WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VA STANDARDS.

PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE

BUILDING CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL

PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE

WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND

THE APPLICABLE BUILDING CODES.

VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED

MOUNTING HARDWARE TO SUIT THE PARTICULAR INSTALLATION.

PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.

BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.

COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO

AVOID CONFLICT DURING CONSTRUCTION.

ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND

ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR

SPARE, OR SPACE.

MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO

INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR

MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE

ACCEPTED. ALL PRODUCTS MUST COMPLY WITH "BUY AMERICAN ACT".

ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR

EQUIPMENT MANUFACTURER'S SPECIFICATIONS.

CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE

DEVICE'S SCREW TERMINALS.

MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT

UNLESS NOTED OTHERWISE.

ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON

VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND

CONDUIT OR WHERE CONCRETE-ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE,

LFMC CONDUIT SHALL BE USED (MAXIMUM SIX FEET) FOR FINAL CONNECTIONS.

ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN

APPROVED THIRD PARTY TESTING AGENCY.

FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE

SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC

PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE

MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT

BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.

PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE

BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS

DETERMINED BY THE GOVERNMENT, SHALL BE PROVIDED.

COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.

20. UNLESS INDICTED OTHERWISE, ALL CONDUIT WILL BE 3/4" 2#12, 1#12 EG, 20AMP. THE TWO #12'S BEING

EITHER A PHASE AND A NEUTRAL FOR 120V CIRCUIT OR TWO PHASE CONDUCTORS FOR A 208V SINGLE

PHASE CIRCUIT.

A

M

ELECTRICAL SYMBOL LEGEND

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

E-001

ELECTRICAL SYMBOLS, GENERAL NOTES

AND ABBREVIATIONS

1 8DS CR

DocuSign Envelope ID: 5355A2AA-0951-4CA6-8B72-503CC0284467

6/4/2019

+84"

+84"

ACAC AC

BCL1-24

BCL1-23

BCL1-39

GFI

+18"ACAC

CCP1-7

ISO

EVAV-1

REF

CI

ANTE

ROOM

STERILE

PREP AREA

1010B

CHEMO

PREP AREA

1010A

HAC

EXISTING

TOILET

+18"

BNL1-38

BNL1-40

EVAV-2

SW-1

CCP1-1

ANTE

ROOM

STERILE

PREP AREA

1010B

CHEMO

PREP AREA

1010A

HAC

EXISTING

TOILET

DESIGNATION

CI

ISO

REF

EF-10

EVAV-1

EVAV-2

SW-1

DESCRIPTION

CHEMO ISOLATOR

MICRO ISOLATOER

REFRIGERATOR

EXHAUST FAN

EXHAUST VARIABLE AIR VOLUME

EXHAUST VARIABLE AIR VOLUME

VAV TERMINAL UNIT

QUAN

VOLT

PH

FLA

0.15

HP

1/2

DEMOLITION EQUIPMENT / MECHANICAL SCHEDULE

VA

CONDUCTORS

2-#12 CU; 1-#12 G

2-#12 CU; 1-#12 G

2-#12 CU; 1-#12 G

3-#12 CU; 1-#12 G

2-#12 CU; 1-#12 G

2-#12 CU; 1-#12 G

2-#12 CU; 1-#12 G

CONDUIT

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

SW

20/1

CB

20/1

20/1

20/1

20/1

20/1

20/1

20/1

FUSE SIZE/TYPE REMARKS

BLOWER 3A, (2) 40W CFL, INTEGRAL WATERTITE REC

HOSPITAL GRADE POWER CORD-STRAIGHT BLADE

BLOWER 5A, (2) 40W CFL, INTEGRAL WATERTITE REC

HOSPITAL GRADE POWER CORD-STRAIGHT BLADE

UNDER COUNTER ON DEDICATED CIRCUIT

REPLACES EXISTING FAN, FOR CHEMO ISOLATOR, CONTROLLED

BY BUILDING AUTOMATION SYSTEM

VERIFY LOCATION W/ MC PRIOR TO ROUGH IN.

CONTROLLED BY BUILDING AUTOMATION SYSTEM

VERIFY LOCATION W/ MC PRIOR TO ROUGH IN.

CONTROLLED BY BUILDING AUTOMATION SYSTEM

VERIFY LOCATION W/ MC PRIOR TO ROUGH IN.

CONTROLLED BY BUILDING AUTOMATION SYSTEM

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR POWER DEMOLITION

A. TRACE AND IDENTIFY ALL CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH,

OR TERMINATE IN THE AREA OF WORK.

DEMOLISH ALL CIRCUIT THAT ARE NO LONGER

IN USE. MAINTAIN CIRCUIT CONTINUITY TO ALL

CIRCUITS WHICH ARE NOT COMPLETELY

REMOVED.

B. DISCONNECT AND REMOVE ELECTRICAL

CONNECTION TO OUTLETS, RECEPTACLES,

HVAC EQUIPMENT AND OTHER ELECTRICAL

DEVICES. REMOVE CONDUCTORS AND

CONDUIT BACK TO PANELBOARD SERVING

EQUIPMENT OR TO THE POINT WHERE OTHER

REMAINING LOADS ARE CONNECTED. MARK

EXISTING OVERCURRENT PROTECTION

DEVICE AS "SPARE (UNUSED)".

C. REMOVE UNUSED ELECTRICAL CONDUIT,

CABLE, WIRING, DEVICE, JUNCTION BOXES,

FITTINGS AND RELATED ITEMS FROM THE

AREA OF WORK INCLUDING WALL, CEILING

AND FLOORS. THIS SHALL APPLY TO WALLS

THAT ARE BEING REMOVED OR WALLS HAVING

DRYWALL OR PLASTER BEING REMOVED AS

PART OF THE PROJECT.

D. FOR ELECTRICAL CIRCUITS BEING

DEMOLISHED REMOVE BOXES, CONDUIT AND

CONDUCTORS BACK TO SOURCE, LEAVING NO

ABANDONED ITEMS.

E. WHERE CONDUIT IS REMOVED FROM AN

EXISTING RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING HOLE SHALL BE

PATCHED/REPAIRED TO MAINTAIN THE RATING

OF THE ASSEMBLY.

F. EACH PHASE OF THE CONSTRUCTION IS TO BE

PERFORMED WHILE LEAVING WORK AREAS OF

OTHER PHASES ACTIVE, TO THE GREATEST

EXTENT POSSIBLE. NOTIFY COR IF ANY WORK

IS REQUIRED THAT WILL CROSS MULTIPLE

PHASES OF THE WORK AREA, PRIOR TO

PERFORMING THE WORK.

G. FOLLOW SITE LOCK-OUT/TAG-OUT

GUIDELINES TO DEENERGIZE EQUIPMENT.

H. COORDINATE DISPOSAL OF DEMOLISHED

EQUIPMENT AND MATERIAL WITH SITE COR.

I. DEVICES INDICATED WITH HIDDEN LINES ARE

TO BE REMOVED, UNLESS NOTED

OTHERWISE.

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

ED101

FIRST FLOOR ELECTRICAL

DEMOLITION PLAN

SHEET NOTES:

SHEET KEY NOTES:

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR LIGHTING DEMOLITION

8DS CR

(E) 1-EF-10

1-EF-11

1-EF-9

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

1. ELECTRICALLY DISCONNECT 1-EF-10'S 1/2 Hp

MOTOR AND REMOVE EXISTING DISCONNECT

SWITCH AND CONDUCTOR BACK TO SOURCE.

MARK BREAKER SPARE IN SOURCE POWER

PANEL SCHEDULE.

2. ELECTRICALLY DISCONNECT 1-EF-9 AND 1-EF-11

MOTOR. REMOVE DISCONNECT SWITCH AND

CONDUCTORS BACK TO SOURCE. MARK

BREAKER SPARE IN SOURCE PANEL SCHEDULE.

ED102

ELECTRICAL ROOF PLANS

DS NJ 3 8

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

PARTIAL ROOF DEMOLITION PLAN

HAC

EXISTING

TOILET

J

J

J

J

J

AC

GFI

DED

J

J

DED DED

CCL1-7

CCP1-19

CCP1-13

CCP1-15

CCP1-9

CCP1-12

CCP1-1

CCP1-17

CCL1-24

T

F

T

F

T

F

"BNL1"

"BCL1"

"CL.L1"

"CNL1"

"CLP1"

"CNT1"

75KVA

"CCT1"

45KVA

"CCL1"

"CLT1"

9 KVA

"CNP1"

"BNL1"

SEC.1 SEC.2

1, 7

26, 28, 30

38, 40 42, SPARE

22, 23, 24

"CCP1"

1. PROVIDE JUNCTION BOX FOR TRANSFORMER

FOR PLUMBING FIXTURES. COORDINATE WITH

DIVISION 22 CONTRACTOR. PROVIDE POWER AS

INDICATED ON PLANS.

2. POWER CONNECTION FOR HEPA FILTERED

CABINET. CIRCUIT TO DEDICATED 120V 20A

CRITICAL BRANCH EMERGENCY POWER CIRCUIT.

3. POWER CONNECTION FOR AUTOMATIC DOORS.

CIRCUIT EACH DOOR TO DEDICATED 20A 120V

EMERGENCY POWER CIRCUIT.

4. POWER CONNECTION FOR PASS-THRU, CIRCUIT

TO DEDICATED 120V 20A CRITICAL BRANCH

EMERGENCY POWER CIRCUIT.

CIRCUIT TO 120V 20A CRITICAL BRANCH EMERGENCY

POWER CIRCUIT.

5. DEDICATED RECEPTACLE FOR REFRIGERATOR.

CIRCUIT TO 120V 20A CRITICAL BRANCH

EMERGENCY POWER CIRCUIT.

6. CIRCUIT TO 120V 20A CRITICAL EMERGENCY

BRANCH POWER CIRCUIT. REUSE EXISTING

CIRCUITS.

A. ALL RECEPTACLE CONDUCTORS ARE 2-12

AWG, 1-12 AWG EG IN 3/4" CONDUIT MINIMUM

UNLESS NOTED OTHERWISE.

B. COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS OF ALL MECHANICAL AND

PLUMBING EQUIPMENT WITH MECHANICAL

AND PLUMBING CONTRACTORS.

C. COORDINATE EQUIPMENT WITH

ARCHITECTURAL EQUIPMENT PLANS AND

SCHEDULES.

D. FOLLOW SITE LOCK-OUT/TAG-OUT

GUIDELINES TO DEENERGIZE EQUIPMENT.

E. ALL EQUIPMENT SHALL HAVE THE SOURCE

PANEL AND CIRCUIT NUMBER INDICATED ON

DEVICE DISCONNECTING MEANS.

F. PURCHASE AND INSTALL APPROPRIATE

CIRCUIT BREAKERS IN PANEL SPACES.

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

EP101

FIRST FLOOR ELECTRICAL PLAN

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR POWER PLAN

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

ELECTRICAL ENLARGEMENTS

DS CR

J

J

J J

J

J

J

HAC

EXISTING

TOILET

ANTE

ROOM

STERILE

PREP AREA

1010B

CHEMO

PREP AREA

1010A

CCL1-29

J

CCL1-16

TB-1

TB-2

TB-3

CCL1-16

CCL1-18

SD1-380

SD1-400

SD1-270

E

E

E

J

CCL1-29

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR MECHANICAL POWER PLAN

1. (TYP) POWER CONNECTION FOR SINGLE DUCT

AIR TERMINAL UNIT. INCLUDES 120V TO 24V

POWER SUPPLY.

2. NON FUSED 3 POLE NEMA1 240V DISCONNECT

SWITCH WHICH FEEDS FANS INSIDE HEPA

FILTERS.

A. ALL RECEPTACLE CONDUCTORS ARE 2-12

AWG, 1-12 AWG EG IN 3/4" CONDUIT MINIMUM

UNLESS NOTED OTHERWISE.

B. COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS OF ALL MECHANICAL AND

PLUMBING EQUIPMENT WITH MECHANICAL

AND PLUMBING CONTRACTORS.

C. COORDINATE EQUIPMENT WITH

ARCHITECTURAL EQUIPMENT PLANS AND

SCHEDULES.

D. ELECTRICAL CONTRACTOR SHALL FOLLOW

SITE LOCK-OUT/TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

E. ALL EQUIPMENT SHALL HAVE THE SOURCE

PANEL AND CIRCUIT NUMBER INDICATED ON

DEVICE DISCONNECTING MEANS.

F. REFERENCE EP101 FOR PANEL LOCATION

ENLARGEMENT. REFERENCE KEY PLAN.

G. PURCHASE AND INSTALL APPROPRIATE

CIRCUIT BREAKERS IN PANEL SPACE.

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

EM101

FIRST FLOOR MECHANICAL

POWER PLAN

8DS CR

1 PRE-BID CHANGES 5-16-19

1-EF-10

CNP-1 30,32,34

3/4" LFMC

3/4" 3#12, EG 1#12

3/4" 2#12, EG 1#12

BNL1-38

GFI

WP

V F

D

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

EM102

MECHANICAL ROOF PLANS

6 8DS NJ

1. INSTALL NEW NEMA 3R 600 V 3 POLE

DISCONNECT SWITCH AHEAD OF VFD/MOTOR.

TIE VFD TO DISCONNECT SWITCH AND MOTOR

(1-EF-10). ELECTRICAL CONTRACTOR SHALL

COORDINATE ROOF PENETRATION AND

DISCONNECT SWITCH SUPPORT STRUCTURE

WITH MECHANICAL CONTRACTOR.

2. INSTALL GFI/WP 120V 20A RECEPTACLE NEAR

1-EF-10. COORDINATE WITH MECHANICAL

CONTRACTOR FOR ROUTING AND ROOF

PENETRATION.

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

PARTIAL ROOF NEW WORK PLAN

CCL1-6

A A

AA

E

ANTE

ROOM

STERILE

PREP AREA

1010B

CHEMO

PREP AREA

1010A

HAC

EXISTING

TOILET

OC

OC

OC

LIGHT FIXTURE SCHEDULE

SYMBOL LABEL TYPE OF LAMP

BALLAST/

DRIVER

WATTS/

FIXTURE

VOLTAGE DESCRIPTION

BASIS OF DESIGN

MANUFACTURER/CATALOG NUMBER

A

LED 3600 LUMEN

4000K 83 CRI

0-10%

DIMMING

34 UNV FLUSH MOUNT SEALED LED CLEAN ROOM FIXTURE

KURTZON MODEL# KLR3-1X4-1/LEDR-40-UNV

OR APPROVED EQUIVALENT

E LED --- 3.3 UNV DAMP LOCATION LED EMERGENCY EXIT SIGN

EMERGI-LITE MODEL#

FR-LEDPXN-1-R-DL

OR APPROVED EQUIVALENT

NOTES:

1. MANUFACTURER AND CATALOG NUMBERS SHOWN ARE FOR BASIS OF DESIGN, DESCRIPTIVE AND QUALITY STANDARDS ONLY, NOT TO BE USED FOR ORDERING WITHOUT VERIFICATION AND APPROVAL.

PROVIDE PRODUCT OR EQUAL FOR APPROVAL BY COR. ENGINEER SHALL NOT BE RESPONSIBLE FOR MISMATCHED OR INACCURATE PART NUMBERS.

2. EM - SWITCHED EMERGENCY LIGHT (CIRCUITED FROM NORMAL AND EMERGENCY BACK-UP POWER)

EM NL - UN-SWITCHED EMERGENCY LIGHT (CIRCUITED FROM EMERGENCY POWER)

NL - NIGHT LIGHT

EX - EXISTING TO REMAIN

R - RELOCATED

3. VERIFY ALL LIGHT FIXTURE MOUNTING TYPES AND COLORS WITH COR.

4. FOR ALL LED LIGHT FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE

MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, WILL

RETURN TO THE SWITCHED/CONTRLLED STATE AUTOMATICALLY. PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

A. ALL LIGHTING CONDUCTORS SHALL BE 2-12

AWG, 1-12 AWG EG IN 3/4" CONDUIT UNLESS

NOTED OTHERWISE.

B. ALL BASEMENT UN-SWITCHED EXIT SIGNS,

NIGHT LIGHTS (NL), STAIRWELL LIGHTS, AND

EMERGENCY LIGHTING UNITS SHALL BE

CIRCUITED FROM LIGHTING CIRCUIT '172-B1'-7,

BUT AHEAD OF ANY CONTROLS OR

SWITCHING.

C. LOCATION AND QUANTITY OF OCCUPANCY

SENSORS IS APPROXIMATE. CONTRACTOR

SHALL FOLLOW MANUFACTURER'S

RECOMMENDED PLACEMENT AND INSTALL

PER MANUFACTURER'S INSTRUCTIONS.

D. CONTRACTOR SHALL VERIFY COMPATIBILITY

OF ALL LIGHTING CONTROLS WITH THE LED

DRIVERS TO BE CONTROLLED.

E. COORDINATE ALL TIME DELAY, AUTO DIM,

PRESET DIMMING LEVELS, SENSOR

SENSITIVITY AND CONFIGURATIONS WITH THE

VA.

F. LIGHTING IN CLEAN ROOM AREA TO BE

PLACED ON EMERGENCY LIFE SAFETY

POWER.

G. PURCHASE AND INSTALL APPROPRIATE

CIRCUIT BREAKERS IN PANEL SPACES.

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

EL101

FIRST FLOOR LIGHTING PLAN

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR LIGHTING PLAN

8DS CR

1. EXISTING LIFE SAFETY BRANCH CIRCUIT

BREAKER CCL1-6 TO POWER NEW LIGHTING

FIXTURES AND EXIT LIGHT.

2. ALL FIXTURE SHALL BE CAPABLE OF BEING

INTEGRATED INTO THE OVERALL BUILDING

ACUITY N-LIGHT CONTROL SYSTEM.

1 ADDENDUM 1 5-8-2019

A

M

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

E-601

PANEL SCHEDULES

8 8DS CR

1. REUSE EXISTING BREAKER.

2. NEW BREAKER.

3. REMARK AS SPARE.

2 2

1 ADDENDUM 1 5-8-2019

TECHNOLOGY SYMBOL LEGEND

DATA OUTLET - 2-4 PR UTP

DATA OUTLET - 1-4 PR UTP

TELCO OUTLET - 1-4 PR UTP

SYMBOL HEIGHT DESCRIPTION

18"

18"

48"

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

SEE DRAWINGS FOR MORE INFORMATION.

NOTE: NOT ALL SYMBOLS ARE USED.

ELECTRONIC LOCKING MECHANISM

DOOR CONTACT

REQUEST FOR EXIT SENSOR

CARD READER

(K - KEYPAD)

48"

CR

ES

DC

RX

48"

EMERGENCY EXIT BUTTON TO RELEASE DOOR (EEB)

WIRELESS ACCESS POINT - 2-4 PR UTP

N

S

NURSE CALL PATIENT STATION WITH PILLOW SPEAKER (GET WELL)

(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANT)

P

NURSE CALL PATIENT BED INTERFACE RECEPTACLE

B

NURSE CALL CODE BLUE STATION

E

NURSE CALL EMERGENCY STATION WITH PULL CORD AND AUDIO +40" AFF IN

RESTROOM, +72" AFF IN SHOWER (V - VANDAL RESISTANT, PB - PUSH BUTTON)

D

NURSE CALL DUTY STATION

M

NURSE CALL MASTER STATION/CONSOLE

NURSE CALL DOME LIGHT

(Z - ZONE LIGHT, V - VANDAL RESISTANT)

IC

INTERCOM STATION

IC

INTERCOM MASTER WITH PUSH TO RELEASE DOOR

M

NURSE CALL WIRELESS ANTENNASNW

DATA OUTLET - 4-4 PR UTP18"

TV OUTLET WALL MOUNTED

DESK

CCTV DOME CAMERA FIXED

CCTV DOME CAMERA PAN/TILT/ZOOM

FOUR POST OIT EQUIPMENT RACK

OIT EQUIPMENT CABINET

NURSE CALL EQUIPMENT CABINET

MATV EQUIPMENT CABINET

CCTV EQUIPMENT CABINET

NCE

MATV

CCTV

LADDER CABLE TARY

FLOOR BOX FOR DATA

AS NOTED

DOOR

DOOR

ABOVE

DOOR

HEADWALL

18"

HEADWALL

/40"

40",72"

18"

60"

CEILING

CEILING

6' TO TOP

6' TO TOP

FLOOR

PHYSICAL ACCESS CONTROL SYSTEM

PACS

6' TO TOP

ELECTRONIC PANIC HARDWARE

EP

DO

DOOR OPERATOR

HANDWAVE

T

C

NURSE CALL STAFF TERMINAL

NURSE CALL PATIENT STATION WITH CALL CORD.

(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANT)

48"

HEADWALL

W WIRELESS PENDANT

L

KP

PATIENT ROAM ALERT ACCESS CONTROL KEYPAD

48"

PATIENT ROAM ALERT ANTENNA

CEILING

GROUND BUS

CEILING

DOOR

DOOR

48"

ABOVE

DOOR

NURSE CALL DOME LIGHT

FLOOR

FLOOR

FLOOR

ABOVE

CEILING

18"

4'x8'x3/4" FIRE RATED TTB

8"

DATA OUTLET - 6-4 PR UTP18"6

N

M

PATIENT STATION (PB - PUSH BUTTON, M - MICROPHONE, K -KEYED)

88"

MOTION DETECTOR

MD

FLOOR TWO POST OIT EQUIPMENT RACK

CEILING MOUNTED SPEAKERS

CEILING

WALL MOUNTED SPEAKERS

96"

S

S

AREA OF REFUGE PANEL

6' TO TOP

AREA OF REFUGE ANNUNCIATION PANEL

6' TO TOP

AOF

AOFA

IC

AREA OF REFUGE INTERCOM

48"

AREA OF REFUGE STROBE LIGHT

CEILING

SL

DP

DPP

DURESS PANIC ALARM PUSH BUTTON

48"

DURESS PANIC ALARM PANEL

6' TO TOP

N

ANTENA/RECEPTORCEILING

F

FIRE ALARM STROBE90" XX - CANDELA

GENERAL TECHNOLOGY NOTES

1. PROVIDE COMMUNICATIONS DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS

WITH DISABILITIES ACT, LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, BICSI STANDARDS, AND VA

STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES AND EQUIPMENT WHERE BUILDING CONSTRUCTION IS NOT

SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP OR PROTECT ANNULAR SPACE AROUND PENETRATIONS THROUGH

WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN ACCORDANCE WITH REQUIREMENTS OF NFPA 70, UL

LISTING REQUIREMENT AND APPLICABLE BUILDING CODES.

4. PROVIDE CABLING THAT COMPLIES WITH LATEST EDITION OF TELECOMMUNICATIONS DISTRIBUTION

METHOD MANUAL AND ANSI/TIA/EIA PUBLICATIONS.

5. COMPLY WITH ANSI/TIA/EIA 758 AND 607B OR 607A - GROUNDING AND BONDING REQUIREMENTS FOR

TELECOMMUNICATIONS IN COMMERCIAL BUILDING.

6. COMPLY WITH ANSI/TIA/EIA 568B - COMMERCIAL BUILDING TELECOMMUNICATIONS WIRING STANDARD.

7. COMPLY WITH ANSI/TIA/EIA 569B - COMMERCIAL BUILDING STANDARD FOR TELECOMMUNICATIONS

PATHWAYS AND SPACES.

8. COMPLY WITH NFPA 70 NATIONAL ELECTRICAL CODE.

9. COMPLY WITH NFPA 99 HEALTHCARE FACILITIES CODE.

10. COMPLY WITH NFPA 101 LIFE SAFETY CODE.

11. COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION.

12. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A

QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.

PRODUCTS DEEMED EQUAL AND APPROVED BY THE COR WILL BE ACCEPTABLE. COMPLY WITH "BUY

AMERICAN ACT".

13. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR EQUIPMENT UNLESS

NOTED OTHERWISE.

14. PROVIDE RGS OR EMT CONDUIT UNLESS OTHERWISE NOTED.

15. PROVIDE MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT LABEL LISTED BY APPROVED THIRD PARTY

TESTING AGENCY.

16. NOTIFY COR REGARDING DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS FOR CLARIFICATION. THE

MORE STRINGENT OF THE THEM SHALL TAKE PRECEDENCE.

17. FOR LOCATION (CORRIDOR, ROOM OR ADJACENT SPACE) WITH TWO OR MORE VISIBLE FIRE ALARM

NOTIFICATION APPLIANCES WITHIN THE FIELD OF VIEW, PROGRAM VISIBLE TO FLASH IN SYNCHRONIZATION.

18. PROVIDE TIA/EIA CAT 6 COPPER OUTLETS AND CONNECTORS.

19. ALL WORK AREA OUTLETS SHALL BE 10 PIN, CAT 6 KEYSTONE JACK WIRED PER T568A OR T568B AS DIRECTED

BY THE VA COR.

20. LABEL DEVICES IN ACCORDANCE WITH LATEST ANSI/TIA 606A OR 606B EDITION AS WELL AS THE STANDARDS

SET FORTH BY THE VA HOSPITAL OIT.

21. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE THE CABLE TRAY PER TIA/EIA 569.B PARAGRAPH 4.5.6.2.

22.

ALL CABLING INSTALLED ABOVE CEILING SHALL BE PLENUM RATED.

ADO AUTOMATIC DOOR OPERATOR

AFF ABOVE FINISH FLOOR

CCTV CLOSED CIRCUIT TELEVISION

COAX COAXIAL CABLE

COMM COMMUNICATION

DC DOOR CONTACT SWITCH

DN DOWN

DO DOOR OPERATOR

DVR DIGITAL VIDEO RECORDER

EEB EMERGENCY EXIT BUTTON

EL ELECTRICAL STRIKE

FA FIRE ALARM

FAP FIRE ALARM PANEL

FAAP FIRE ALARM ANNUNCIATOR PANEL

FO FIBER OPTIC

IT INTERCOMMUNICATION ROOM

MATV MASTER ANTENNA TELEVISION

MM MULTI MODE FIBER

NAC NETWORK APPLIANCES CONTROL PANEL

NS NO SCALE

NVR NETWORK VIDEO RECORDER

TECHNOLOGY ABBREVIATIONS LIST

OC ON CENTER

OIT OFFICE OF INFORMATION TECHNOLOGY

PACS PHYSICAL ACCESS CONTROL SYSTEM

PAMN PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEM

PB PUSH BUTTON

PDU RACK POWER DISTRIBUTION UNITS

POE POWER OVER ETHERNET

PR PAIR

RX REQUEST TO EXIT

SEP SERVICE ENTRANCE PROTECTION

SM SINGLE MODE FIBER

TEL TELEPHONE

TGB TELECOMM GROUND BUS BAR

TMGB TELECOMM MAIN GROUND BUS BAR

TP TWISTED PAIR

TR TELECOMM ROOM

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

WM WIRE MANAGEMENT

UL UNDERWRITERS LABORATORY

UPS UNINTERRUPTIBLE POWER SUPPLY

UTP UNSHIELDED TWISTED PAIR

WAP WIRELESS ACCESS POINT

A

M

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

TK001

TECHNOLOGY SYMBOLS, GENERAL

NOTES AND ABBREVIATIONS

1 2DS JDM

HAC

EXISTING

TOILET

4 4

RX

RX

RX

W

F

15Cd

DOOR

1010B

RX RX

DOOR

1010A

RX

DOOR

TO

4 PR UTP 120V EMERGENCY POWER

42"

60"

48"

NOTES:

1. SLIDING DOOR MICROPROCESSOR

CONTROL BOX

2. INTERLOCK CABLING IN 1" CONDUIT.

VERIFY WITH MANUFACTURER OF

SLIDING DOOR.

3. REQUEST FOR EXIT CABLING IN 1/2"

CONDUIT.

4. HANDWAVE CABLING IN 1/2" CONDUIT.

5. DOOR CONTROLLER TO CONTROL ALL 3

DOORS. INTERLOCK WITH THE SLIDING

DOOR CONTROL BOX. ONLY ONE DOOR

TO OPEN AT A TIME (IN NORMAL

OPERATION.

6. PROVIDE 4-PR UTP TO NEAREST IT

ROOM.

3 3

60"

42"

46"

1. PROVIDE (4) - 4 PR UTP CAT6 TO THE NEAREST

IT ROOM.

2. PROVIDE WALL PHONE JACK W/ CABLE TO

NEAREST IT ROOM.

3. PROVIDE 5 MEGAPIXEL DOME CAMERA WITH

CABLE TO IT ROOM.

4. PROVIDE REQUEST TO EXIT AND HARDWARE

DEVICES FOR THE THREE SLIDING DOORS.

INTERLOCK ALL THREE DOORS SO ONLY ONE

DOOR WILL OPEN AT ANY GIVEN TIME. PROVIDE

CONTROLLERS AS REQUIRED.

5. PROVIDE FIRE ALARM STROBE AND CONNECT

TO THE NEAREST FIRE ALARM ZONE CIRCUIT IN

THE PHARMACY (MATCH EXISTING

NOTIFICATION SYSTEM).

6. PROVIDE 2-4 PR UTP FOR WAP TO NEAREST IT

ROOM.

A. SEE SLIDING DOORS DETAIL FOR MORE

INFORMATION.

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

SHEET NOTES:

SHEET KEY NOTES:

321 4 5 6 7

A B

C D

E

Dwg. of

LocationLocation

Office of

Construction and Facilities

Management

PROJECT MANAGER:

ACG Project Number

CONSULTANTS:

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

NC License #: C-1848

U.S. Department of Veterans Affairs

© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date# 05/30/2019

GRAND JUNCTION VA MEDICAL

CENTER - UPGRADE HAZARDOUS

DRUG WORKSPACE

575-18-110

VA WESTERN COLORADO

HEALTH CARE SYSTEM

2121 NORTH AVENUE

GRAND JUNCTION, CO 81501

18-235

100% BID DOCUMENTS

FULLY SPRINKLERED

Structural Engineer:

N

AREA OF

WORK

KEY PLAN

ELECTRICAL

CLOSET

TK101

FIRST FLOOR TECHNOLOGY

PLAN

0 4 8 16

NORTH

PLAN

Scale: 1/4" = 1'-0"

FIRST FLOOR TECHNOLOGY PLAN

2DS ABT

Scale: N.T.S.

SLIDING DOORS WIRING DIAGRAM

Sheets and Views
E-001-E-001
ED101-ED101
ED102-ED102
EP101-EP101
EM101-EM101
EM102-EM102
EL101-EL101
E-601-E-601
TK001-E-001
TK101-EP101