Asbestos Bulk Analysis Reports - 9 Rpts.pdf
PDF 774 KB Posted
- Solicitation number
- 36C25726Q0769
About this file
This document is a collection of asbestos bulk analysis laboratory reports for samples collected from Audie Murphy VA in San Antonio, Texas. The reports were prepared by Environmental Hazards Services, L.L.C., with all samples received on August 12, 2013, analyzed on August 13-14, 2013, and reported on August 14, 2013.
The analysis covered nine sample sets from different interstitial areas (AC-1-1A, AC-1-1D, AC-1-1E, AC-1-2A, AC-1-2B, AC-1-3E, AC-1-4A, AC-1-4E, and AC-1-6A), with each set containing nine samples examined for asbestos content using EPA Methods 600/R-93/116 and 600/M4-82-020 via polarized light microscopy. The reporting limit was 1% asbestos. Key findings indicate asbestos presence in several samples: 5% chrysotile in AC-1-1A sample 1 and AC-1-4A sample 1; 3% chrysotile in AC-1-1E samples 1 and 8, AC-1-2A sample 1, and AC-1-3E sample 1; and 2% chrysotile in AC-1-4E sample 1 and AC-1-1E sample 8. Remaining samples showed no asbestos detected (NAD) or did not analyze due to positive stop procedures. All samples contained various non-asbestos materials including cellulose, wollastonite, fibrous glass, talc, and non-fibrous components. Quality control procedures employed SRM 1866 Fiberglass blank and identified QC samples, with results reviewed and authorized by Tasha Eaddy, QA/QC Clerk.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25726Q0769 0005.pdf | ||
| Second Site Visit sign-in sheet.pdf | ||
| 36C25726Q0769 0005_1.docx | DOCX document | |
| Environmental Liability ACM Worksheet FY26 Q3_rsp.xlsx | XLSX spreadsheet | |
| 1st Floor Interstitial - 8 Pictures.pdf | ||
| BA ASI No 001 - Supply Duct.pdf | ||
| 36C25726Q0769-RFI-Technical Questions-Second Site Visit.pdf | ||
| 36C25726Q0769-RFI-Technical Questions.pdf | ||
| 36C25726Q0769 0004.pdf | ||
| 36C25726Q0769 0004_1.docx | DOCX document | |
| Total Report.pdf | ||
| 36C25726Q0769 0003_1.docx | DOCX document | |
| 36C25726Q0769 0003.pdf | ||
| 36C25726Q0769 0002.pdf | ||
| 36C25726Q0769 0002_1.docx | DOCX document | |
| SOW - Repair Duct and Chilled Water Insulation - v3.pdf | ||
| 36C25726Q0769 0001_1.docx | DOCX document | |
| Site Visit - Repair Duct and Chilled Water Lines - Sign-in.pdf | ||
| 36C25726Q0769 0001.pdf | ||
| SOW - Repair Duct and Chilled Water Insulation - v2.pdf | ||
| Attachment 1 Wage Determination No 2015-5253.pdf | ||
| 36C25726Q0769_1.docx | DOCX document | |
| 36C25726Q0769.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Bulk Analysis Report
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01474
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC-1-1A; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Adhesive;
Homogeneous
13-08-01474-001 1-DM 95% Non-Fibrous5% Chrysotile
5%Total Asbestos:
13-08-01474-002 2-DM Did Not Analyze (Positive Stop)
13-08-01474-003 3-DM Did Not Analyze (Positive Stop)
Brown Wood; White Brittle;
Inhomogeneous
13-08-01474-004 4-CM 15% Cellulose 85% Non-Fibrous
NAD
Brown Wood; White Brittle;
Inhomogeneous
13-08-01474-005 5-CM 15% Cellulose 85% Non-Fibrous
NAD
Brown Wood; White Brittle;
Inhomogeneous
13-08-01474-006 6-CM 15% Cellulose 85% Non-Fibrous
NAD
1 of 2Page
White Adhesive;
Homogeneous
13-08-01474-007 7-PM 5% Wollastonite 95% Non-Fibrous
NAD
White Adhesive;
Homogeneous
13-08-01474-008 8-PM 5% Wollastonite 95% Non-Fibrous
NAD
White Adhesive;
Homogeneous
13-08-01474-009 9-PM 5% Wollastonite 95% Non-Fibrous
NAD
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Araceli Enzler
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
18-M11995-3
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01474
Audie Murphy VA - 1st Interstitial AC-1-1A; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
2 of 2Page
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01463
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC 1-1D; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Brittle;
Homogeneous
13-08-01463-001 1-FM 1% Cellulose 99% Non-Fibrous
NAD
White Brittle;
Homogeneous
13-08-01463-002 2-FM 1% Cellulose 99% Non-Fibrous
NAD
White Brittle;
Homogeneous
13-08-01463-003 3-FM 1% Cellulose 1% Fibrous Glass 98% Non-Fibrous
NAD
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01463-004 4-CM 70% Cellulose 30% Non-Fibrous
NAD
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01463-005 5-CM 70% Cellulose 30% Non-Fibrous
1 of 3Page
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01463-006 6-CM 70% Cellulose 30% Non-Fibrous
NAD
Off-White Pliable;
Homogeneous
13-08-01463-007 7-PM 3% Fibrous Glass 7% Wollastonite 90% Non-Fibrous
NAD
Off-White Pliable;
Homogeneous
13-08-01463-008 8-PM 1% Cellulose 2% Fibrous Glass 7% Wollastonite 90% Non-Fibrous
NAD
Off-White Pliable;
Homogeneous
13-08-01463-009 9-PM 1% Cellulose 2% Fibrous Glass 7% Wollastonite 90% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01463
Audie Murphy VA - 1st Interstitial AC 1-1D; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
2 of 3Page
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01463
Audie Murphy VA - 1st Interstitial AC 1-1D; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Mark Case
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
13-M11996-1
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
3 of 3Page
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01476
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC1-1E; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Pliable; Brown Fibrous; Silver Foil-Like;
Inhomogeneous
13-08-01476-001 1-DM 10% Cellulose 87% Non-Fibrous
3% Chrysotile
Chrysotile present in white pliable material.
3%Total Asbestos:
13-08-01476-002 2-DM Did Not Analyze (Positive Stop)
13-08-01476-003 3-DM Did Not Analyze (Positive Stop)
White Granular; Brown Fibrous; Inhomogeneous
13-08-01476-004 4-CM 50% Cellulose 50% Non-Fibrous
NAD
White Granular; Brown Fibrous; Inhomogeneous
13-08-01476-005 5-CM 50% Cellulose 50% Non-Fibrous
White Granular; Brown Fibrous; Inhomogeneous
13-08-01476-006 6-CM 50% Cellulose 50% Non-Fibrous
NAD
White Pliable; Yellow Fibrous; Inhomogeneous
13-08-01476-007 7-PM 2% Cellulose 18% Fibrous Glass 5% Wollastonite 75% Non-Fibrous
NAD
White Pliable; Black Foam-Like;
Inhomogeneous
13-08-01476-008 8-PM 2% Cellulose 96% Non-Fibrous
2% Chrysotile
Chrysotile present in white pliable material.
2%Total Asbestos:
13-08-01476-009 9-PM Did Not Analyze (Positive Stop)
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01476
Audie Murphy VA - 1st Interstitial AC1-1E;
San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
Client Number: Report Number:45-5371 13-08-01476
Audie Murphy VA - 1st Interstitial AC1-1E;
San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Timothy Harris
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
18-M11995-3
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01470
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC 1-2A; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
Off-White Pliable;
Homogeneous
13-08-01470-001 1-DM 1% Fibrous Glass 1% Talc 95% Non-Fibrous
3% Chrysotile
3%Total Asbestos:
13-08-01470-002 2-DM Did Not Analyze (Positive Stop)
13-08-01470-003 3-DM Did Not Analyze (Positive Stop)
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01470-004 4-CM 70% Cellulose 30% Non-Fibrous
NAD
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01470-005 5-CM 70% Cellulose 30% Non-Fibrous
13-08-01470-006 6-CM 70% Cellulose 30% Non-Fibrous
NAD
White to Pale Beige Pliable; Homogeneous
13-08-01470-007 7-PM 8% Wollastonite 92% Non-Fibrous
NAD
White to Pale Beige Pliable; Homogeneous
13-08-01470-008 8-PM 8% Wollastonite 92% Non-Fibrous
NAD
White to Pale Beige Pliable; Homogeneous
13-08-01470-009 9-PM 8% Wollastonite 92% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01470
Audie Murphy VA - 1st Interstitial AC 1-2A; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
Client Number: Report Number:45-5371 13-08-01470
Audie Murphy VA - 1st Interstitial AC 1-2A; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Mark Case
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
13-M11996-1
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01458
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC 1-2B; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/14/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Brittle; Clear Adhesive; Inhomogeneous
13-08-01458-001 1-DM 100% Non-FibrousNAD
White Brittle; Clear Adhesive; Inhomogeneous
13-08-01458-002 2-DM 100% Non-FibrousNAD
White Brittle; Clear Adhesive; Inhomogeneous
13-08-01458-003 3-DM 100% Non-FibrousNAD
White Brittle; Brown Fibrous; Inhomogeneous
13-08-01458-004 4-CM 55% Cellulose 45% Non-Fibrous
NAD
White Brittle; Brown Fibrous; Inhomogeneous
13-08-01458-005 5-CM 55% Cellulose 45% Non-Fibrous
White Brittle; Brown
13-08-01458-006 6-CM 55% Cellulose 45% Non-Fibrous
NAD
White Adhesive;
Homogeneous
13-08-01458-007 7-PM 100% Non-FibrousNAD
White Adhesive;
Homogeneous
13-08-01458-008 8-PM 100% Non-FibrousNAD
White Adhesive;
Homogeneous
13-08-01458-009 9-PM 100% Non-FibrousNAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01458
Audie Murphy VA - 1st Interstitial AC 1-2B; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
Client Number: Report Number:45-5371 13-08-01458
Audie Murphy VA - 1st Interstitial AC 1-2B; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Sami Hosn
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
18-M11995-3
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01464
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC 1-3E; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
Off-White Pliable;
Homogeneous
13-08-01464-001 1-DM 1% Fibrous Glass 1% Talc 95% Non-Fibrous
3% Chrysotile
3%Total Asbestos:
13-08-01464-002 2-DM Did Not Analyze (Positive Stop)
13-08-01464-003 3-DM Did Not Analyze (Positive Stop)
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01464-004 4-CM 70% Cellulose 30% Non-Fibrous
NAD
Tan Fibrous; White Brittle;
Inhomogeneous
13-08-01464-005 5-CM 70% Cellulose 30% Non-Fibrous
13-08-01464-006 6-CM 70% Cellulose 30% Non-Fibrous
NAD
Off-White Pliable;
Inhomogeneous
13-08-01464-007 7-PM 8% Wollastonite 92% Non-Fibrous
NAD
Off-White Pliable;
Inhomogeneous
13-08-01464-008 8-PM 8% Wollastonite 92% Non-Fibrous
NAD
Off-White Pliable;
Inhomogeneous
13-08-01464-009 9-PM 8% Wollastonite 92% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01464
Audie Murphy VA - 1st Interstitial AC 1-3E; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
Client Number: Report Number:45-5371 13-08-01464
Audie Murphy VA - 1st Interstitial AC 1-3E; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Mark Case
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
13-M11996-1
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01471
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC 1-4A; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Adhesive;
Homogeneous
13-08-01471-001 1-DM 95% Non-Fibrous5% Chrysotile
5%Total Asbestos:
13-08-01471-002 2-DM Did Not Analyze (Positive Stop)
13-08-01471-003 3-DM Did Not Analyze (Positive Stop)
Brown Wood; White Brittle;
Inhomogeneous
13-08-01471-004 4-CM 15% Cellulose 85% Non-Fibrous
NAD
Brown Wood; White Brittle;
Inhomogeneous
13-08-01471-005 5-CM 15% Cellulose 85% Non-Fibrous
NAD
Brown Wood; White Brittle;
Inhomogeneous
13-08-01471-006 6-CM 15% Cellulose 85% Non-Fibrous
1 of 2Page
White Adhesive;
13-08-01471-007 7-PM 5% Wollastonite 95% Non-Fibrous
NAD
White Adhesive;
Homogeneous
13-08-01471-008 8-PM 5% Wollastonite 95% Non-Fibrous
NAD
White Adhesive;
Homogeneous
13-08-01471-009 9-PM 5% Wollastonite 95% Non-Fibrous
NAD
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Araceli Enzler
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
18-M11995-3
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01471
Audie Murphy VA - 1st Interstitial AC 1-4A; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
2 of 2Page
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01478
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC-1-4E; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/13/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
Off White Adhesive;
Homogeneous
13-08-01478-001 1-DM 1% Wollastonite 97% Non-Fibrous
2% Chrysotile
2%Total Asbestos:
13-08-01478-002 2-DM Did Not Analyze (Positive Stop)
13-08-01478-003 3-DM Did Not Analyze (Positive Stop)
White Brittle; Tan Fibrous;
Inhomogeneous
13-08-01478-004 4-CM 65% Cellulose 35% Non-Fibrous
NAD
White Brittle; Tan Fibrous;
Inhomogeneous
13-08-01478-005 5-CM 65% Cellulose 35% Non-Fibrous
NAD
White Brittle; Tan Fibrous;
Inhomogeneous
13-08-01478-006 6-CM 65% Cellulose 35% Non-Fibrous
Off White Adhesive;
13-08-01478-007 7-PM 1% Cellulose 6% Wollastonite 93% Non-Fibrous
NAD
Off White Adhesive;
Homogeneous
13-08-01478-008 8-PM 1% Cellulose 6% Wollastonite 93% Non-Fibrous
NAD
Off White Adhesive;
Homogeneous
13-08-01478-009 9-PM 6% Wollastonite 94% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01478
Audie Murphy VA - 1st Interstitial AC-1-4E; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
Client Number: Report Number:45-5371 13-08-01478
Audie Murphy VA - 1st Interstitial AC-1-4E; San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Michelle Swift
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
65-M12003-3
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
AEHS 08/12/2013
45-5371
08/14/2013
13-08-01479
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
Audie Murphy VA - 1st Interstitial AC1-6A; San Antonio, TX
Laboratory Results Fax Number:
210-656-8499
4402 Center Gate San Antonio, TX 78217
08/14/2013
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Brittle;
Homogeneous
13-08-01479-001 1-DM 100% Non-FibrousNAD
White Brittle;
Homogeneous
13-08-01479-002 2-DM 100% Non-FibrousNAD
White Brittle;
Homogeneous
13-08-01479-003 3-DM 100% Non-FibrousNAD
White Brittle; Brown Fibrous; Inhomogeneous
13-08-01479-004 4-CM 55% Cellulose 45% Non-Fibrous
NAD
White Brittle; Brown Fibrous; Inhomogeneous
13-08-01479-005 5-CM 55% Cellulose 45% Non-Fibrous
White Brittle; Brown
13-08-01479-006 6-CM 55% Cellulose 45% Non-Fibrous
NAD
White Adhesive;
Homogeneous
13-08-01479-007 7-PM 100% Non-FibrousNAD
White Adhesive;
Homogeneous
13-08-01479-008 8-PM 100% Non-FibrousNAD
White Adhesive;
Homogeneous
13-08-01479-009 9-PM 100% Non-FibrousNAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-5371 13-08-01479
Audie Murphy VA - 1st Interstitial AC1-6A;
San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
Client Number: Report Number:45-5371 13-08-01479
Audie Murphy VA - 1st Interstitial AC1-6A;
San Antonio, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Sami Hosn
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
18-M11995-3
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
| 1st Floor Interstitial (AC-1-1A) |
| File837787.pdf |
| page 2 |
File837327.pdf
| 1st Floor Interstitial (AC-1-1D) |
| File837804.pdf |
| page 2 |
| page 3 |
File837323.pdf
| 1st Floor Interstitial (AC-1-1E) |
| File837931.pdf |
| page 2 |
| page 3 |
File837491.pdf
| 1st Floor Interstitial (AC-1-2A) |
| File837754.pdf |
| page 2 |
| page 3 |
File837325.pdf
| 1st Floor Interstitial (AC-1-2B) |
| File837742.pdf |
| page 2 |
| page 3 |
File837368.pdf
| 1st Floor Interstitial (AC-1-3E) |
| File837760.pdf |
| page 2 |
| page 3 |
File837324.pdf
| 1st Floor Interstitial (AC-1-4A) |
| File837813.pdf |
| page 2 |
File837326.pdf
| 1st Floor Interstitial (AC-1-4E) |
| File837828.pdf |
| page 2 |
| page 3 |
File836968.pdf
| 1st Floor Interstitial (AC-1-6A) |
| File837745.pdf |
| page 2 |
| page 3 |
File837492.pdf
File details come from the government source that posted it. Updated .