Bldg70Insp MgmtPlan3YearUpdate2014.pdf
PDF 13 MB Posted
- Solicitation number
- 36C25726B0001
About this file
This is an AHERA (Asbestos Hazard Emergency Response Act) Asbestos Inspection & Management Plan for the VA Medical Center Dallas, Texas, specifically covering Buildings 70, 37, and the Turbine Yard. The document reports on comprehensive asbestos surveys conducted in March and April 2010, with a three-year reassessment completed in June 2014. Buildings 70 and 37, constructed in 1994, comprise approximately 34,726 square feet and serve as the Energy Center and Air Conditioning Cooling Tower facility, respectively. The inspection was performed by Micro Air of Texas, Inc., with accredited inspectors Jennifer McMillin and Lisa McGarrah holding valid Texas DSHS licenses. Laboratory analysis by J3 Resources, Inc., an NIST-accredited facility, examined 128 bulk samples from Building 70, 6 samples from Building 37, and 17 samples from the newly constructed Turbine Yard using Polarized Light Microscopy (PLM) methodology in accordance with EPA standards.
The management plan documents material assessments across 36 homogeneous sampling areas (HA-01 through HA-36) in Building 70, 2 areas in Building 37, and 6 areas in the Turbine Yard, encompassing various materials including thermal system insulation (colored and painted fiberglass pipe insulation with mastics), floor tiles, ceiling tiles, gaskets, and duct sealants. Notably, all laboratory analysis results indicate that none of the tested materials contain asbestos (all samples reported "No" for asbestos content). The document specifies that designated persons Thomas Rattler or Ken Taylor are responsible for implementation of the management plan, with engineering contact Charles Ballard at 214-857-1069. The plan includes provisions for Operations & Maintenance programs, six-month surveillance documentation, and three-year reinspection schedules as required under AHERA and TAHPA protocols, with no immediate response actions recommended given the absence of asbestos-containing materials.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA MEDICAL CENTER
DALLAS, TEXAS
BUILDINGS 70, 37, & TURBINE YARD
A.H.E.R.A. ASBESTOS INSPECTION
MANAGEMENT PLAN
3 - YEAR REASSESSMENT & UPDATE - 2014
PREPARED FOR:
VA NORTH TEXAS HEALTH CARE SYSTEM
ENGINEERING SERVICES
4500 S. LANCASTER ROAD
DALLAS, TX 75216
MICRO AIR PROJECT #B-1403
PREPARED BY:
MICRO AIR OF TEXAS, INC.
P.O. Box 1225 Dickinson, TX 77539
(281) 280-9965
DALLAS, TEXAS
AHERA
ASBESTOS INSPECTION
PREPARED FOR:
VA NORTH TEXAS HEALTH CARE SYSTEM
ENGINEERING SERVICES
4500 S. LANCASTER ROAD
DALLAS, TX 75216
PREPARED BY:
MICRO AIR OF TEXAS, INC.
P.O. Box 1225 Dickinson, TX 77539
(281) 280-9965
Inspection Dates: March 23 and 24, 2010 and April 7, 2010
Individual Asbestos Consultant: ________________________
DSHS License # 10-5436
TABLE OF CONTENTS
Page #
General Inventory Management Plan Format
Section I - AHERA Asbestos Inspection General Information
Introduction, Required Information, & Facility Description 1 - 3
Section II - Asbestos Methodology & Lab Analytical Report
Methodology 1 Classification 1 Limitations 2 Homogeneous Sampling Area Summary Table 3 - 8 Laboratory Report Sample Location Drawing(s)
Section III - ACM Material Assessment & Quantification
General Information 1 Building 70 Surfacing Materials 2 Thermal System Insulation Materials 2 - 11 Miscellaneous Materials 12 - 16 Building 37 Surfacing Materials 17 Thermal System Insulation Materials 17 Miscellaneous Materials 17 - 18 Turbine Yard 19 Surfacing Materials 19 Thermal System Insulation Materials 19 - 21 Miscellaneous Materials 21
Section IV - Asbestos Material Response Action Recommendations
This Section is Not Applicable 1
Section V - Operations & Maintenance Program
Purpose / This Section is Not Applicable 1
Section VI - Facility Owner / Designated Person(s)
Licenses and Training Certificates
Section VII - Six Month Surveillance Documentation - Not Applicable
Section VIII - Three Year Reinspection Updates / Schedule
Section IX - Response Actions - Not Applicable
BUILDING INSPECTION FOR FRIABLE AND NON-FRIABLE ACM
GENERAL INVENTORY
FACILITY ID: Buildings 70, 37, and Turbine Yard
ORIGINAL INSPECTION COMPLETION DATES BLDG 70 & 37: March 23 and 24, 2010 and April 7, 2010
ORIGINAL INSPECTION COMPLETION DATE FOR TURBINE BUILDING: June 10, 2014 3-YEAR REASSESSMENT INSPECTION COMPLETION DATE: June 10, 2014
FACILITY ADDRESS: Buildings 70 and 37
VAMC
4500 S. Lancaster Rd.
Dallas, TX 75216
TOTAL SQUARE FOOTAGE: APPROXIMATELY 34,726 Square Feet
YEAR CONSTRUCTED: 1994
USE OF FACILITY: Energy Center (Building 70) and Air Conditioning Cooling Tower (Building 37) and Turbine Yard
DESIGNATED PERSON: Thomas Rattler or Ken Taylor
ENGINEERING PHONE: 214-857-1069 - Contact Charles Ballard
INSPECTION COMPANY: MICRO AIR OF TEXAS, INC.
P.O. Box 1225 Dickinson, TX 77539
PHONE: (281) 280-9965
NAME OF ACCREDITED PERSON
PERFORMING INSPECTION: JENNIFER MCMILLIN (DSHS LICENCE # 60-1893)
LISA MCGARRAH (DSHS LICENSE # 60-2923)
ACCREDITATION AGENCY: TEXAS DEPT. OF STATE HEALTH SERVICES
ACCREDITATION #: N/A
THIS BUILDING CONTAINS:
1. FRIABLE ACBM
2. NON-FRIABLE ACBM
3. FRIABLE MATERIAL
(ASSUMED TO BE ACBM)
4. NON-FRIABLE MATERIAL
(ASSUMED TO BE ACBM)
5. NONE OF THE ABOVE X
______________________________________ 5/21/10 & 6/10/14
ACCREDITED INSPECTOR DATE
DSHS LICENSE # 60-1893
_______________________________________ 5/21/10
ACCREDITED INSPECTOR DATE
DSHS LICENSE # 60-2923
BUILDINGS 70, 37, & TURBINE YARD
DALLAS, TX
A.H.E.R.A. ASBESTOS INSPECTION &
MANAGEMENT PLAN
PREPARED FOR:
VA NORTH TEXAS HEALTH CARE SYSTEM
ENGINEERING SERVICES
4500 S. LANCASTER ROAD
DALLAS, TX 75216
MICRO AIR PROJECT #B-1403
PREPARED BY:
MICRO AIR OF TEXAS, INC.
P.O. Box 1225
MICRO AIR OF TEXAS, INC. BUILDINGS 70, 37, & Turbine Yard - VA Medical Center; Dallas, TX
AHERA ASBESTOS INSPECTION & MANAGEMENT PLAN
P.O. Box 1225
MANAGEMENT PLAN FORMAT
SECTION I: This section contains general information regarding the AHERA survey and management plan, required information, and a facility description.
SECTION II: This section contains general information, sampling information, and Homogeneous Sample Area Summary. The laboratory analytical report for the bulk samples collected during the 2010 inspection has been included. Additionally, information on the survey report and classification of homogeneous areas is located in this section. Drawings depicting the locations of all bulk building material samples collected and asbestos-containing homogeneous area locations can be found in this sub-section.
SECTION III: This section contains material assessments and quantification which are used to develop the appropriate response actions for the management plan. Photographs of each asbestos-containing material identified has been included in this section.
SECTION IV: This section contains the recommended response actions for each type of ACM in the facility including recommendations for immediate abatement, if necessary. Immediate response action recommendations are prioritized.
SECTION V: This section contains an updated Operations and Maintenance Program for the facility.
This program includes recommendations for ongoing maintenance functions.
SECTION VI: This section has been reserved for informational purposes. This section includes the Facility Owner / Designated Person information, as well as the Re-inspection / Periodic Surveillance Schedule. All applicable licenses, certifications, and accreditations of the Inspector, Management Planner, and Laboratory performing services on this Management Plan are also included in this section.
SECTION VII: This section has been reserved for reports for the six month inspections, assessments, and any ambient air monitoring.
SECTION VIII: This section has been reserved for documentation obtained from three year re-inspections. Updates to the Management Plan are to be included in this section.
SECTION IX: This section has been reserved for the owner to reference abatement response action reports and building maintenance action (O&M) reports. All documentation from asbestos abatement activities should also be included in this section.
SECTION I
AHERA ASBESTOS INSPECTION
SECTION I - GENERAL INFORMATION
INTRODUCTION
Micro Air of Texas, Inc. (Micro Air) was contracted by the Veterans Administration North Texas Health Care System (VANTHCS) located in Dallas, Texas to perform an asbestos inspection and generate a management plan in accordance with guidelines established in 40 CFR 763, the Asbestos Hazard Emergency Response Act of 1987 (AHERA), for the aforementioned facility located in Dallas, Texas. This facility consists of numerous buildings constructed between 1940 and 2009. This particular report pertains to Buildings 70 and 37. Building 70 is the Energy Center; Building 37 is the Air Conditioning Cooling Tower located behind the Energy Center. Based on information we obtained from VA personnel, Buildings 70 and 37 were constructed in 1994.
During the 2014 3-Year Asbestos Assessment and Re-inspection, Micro Air noted that the Turbine Yard had been added to the north end of the Energy Center. Construction of this area was completed in 2014. Micro Air conducted an asbestos inspection on the Turbine Yard and the north end of the Building 70 where new pipe insulation had been installed as part of the construction of the Turbine Yard. A total of 17 bulk building material samples were collected in June, 2014, and the results were included in this management plan.
Micro Air performed a comprehensive asbestos survey of Building 70 on March 23 and 24, 2010; the comprehensive asbestos survey of Building 37 (Cooling Tower) was completed on April 7, 2010. After the comprehensive asbestos survey results were compiled, a Management Planner accredited by an EPA-approved training provider and licensed as an Individual Asbestos Consultant in the state of Texas, reviewed the analytical results of the inspection and current physical condition assessments. The management planner then determined the potential hazard posed by the ACM and evaluated and selected control / response options based on all compiled information. This information was then composed and written into a final report.
The federal National Emission Standard for Asbestos (NESHAP) and the Texas Asbestos Health Protection Act (TAHPA) both require that prior to any demolition or renovation activity in a building, a thorough inspection of the affected facility or part of the facility where the demolition or renovation operation will occur, must be performed for the presence of asbestos, including Category I and Category II non-friable asbestos-containing material (ACM).
Additionally, TAHPA requires that a minimum of three samples be collected from each homogeneous sampling area (material type) identified in the building. The work area and immediately surrounding areas which could foreseeably be disturbed by the actions necessary to perform the project must be inspected and sampled as applicable prior to renovations or demolition. While the VANTHCS is not subject to the TAHPA regulation, due to its exclusion as a federal facility, Micro Air collected bulk samples in accordance with TAHPA and AHERA protocol at the request of the VANTHCS engineering personnel.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 1
REQUIRED INFORMATION
In accordance with AHERA protocol, the VAMC located in Dallas, Texas is required to name a person who shall be responsible for implementation of the management plan (Designated Person - see Section V). Per the Occupational Safety and Health Administration (OSHA) 1926.1101, construction industry standard, maintenance personnel should be made aware of the types and locations of all facility ACM. These employees are required to have adequate asbestos awareness training (minimum 2 hours), and all maintenance personnel who may come in contact with or disturb ACM are required to receive a minimum of 16 hours of asbestos training in asbestos hazards and recognition of ACM. If the owner wishes to perform ACM activities with its own personnel, the owner is responsible for obtaining the required EPA training in accordance with the Model Accreditation Plan (MAP), which is located in Appendix C, Subpart E of 40 CFR, 763 (AHERA). Additionally, all OSHA requirements must be met, as well (i.e., asbestos physical, etc.). Otherwise, it is recommended that all ACM activities be performed by a Texas licensed Asbestos Contractor, and project oversight be conducted by a Texas licensed Asbestos Consultant Agency.
In accordance with the VA directive to comply with AHERA, the entire facility must be re-inspected and a reassessment of ACM conducted by an accredited inspector at least once every three years, and the management plan should be updated by a licensed Asbestos Inspector / Management Planner or Individual Asbestos Consultant. Additionally, visual inspections of the ACM must also be made by the Designated Person for the facility at least once every six months to determine whether any areas of the material have changed in condition, or if there are any other factors which may necessitate abatement actions.
FACILITY DESCRIPTION
Building 70 is an approximately 34,726 square foot, two-story structure (one floor and elevated catwalk areas), and currently serves as the Energy Center at the Dallas VA. The construction date of this building is believed to be 1994. The interior finish materials consist primarily of concrete floors with CMU block walls and unfinished ceilings. Office areas and hallways are finished with 12 inch by 12 inch vinyl floor tile, ceramic tile, 18 inch by 18 inch plastic tiles in a metal frame raised approximately one foot above the concrete floor, and carpet. Sheet rock walls with painted texture and lay-in ceilings (two foot by four foot and two foot by two foot ceiling tiles) are present in the office areas and hallways.
Several types of color-coded insulated piping systems are present in the plant areas (Rooms 106 and 107) and tunnel entrance. Insulated piping is primarily fiberglass with PVC joints.
Four boilers were observed in Room 106. Six chillers are present in Room 107. Vibrations joints associated with the HVAC system were rubber.
The exterior of the Energy Building is tilt-up concrete panels and a flat, tar and gravel roof.
The Air Conditioning Cooling Tower (Building 37) is located behind the Energy Center. The cooling tower includes six cells (one for each chiller), and is a metal structure with metal brackets on concrete footings. Fiberglass slats were observed inside the cooling tower cells.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 2
Rubber matts are located at the base of the structure and rubber gaskets were observed on metal piping outside of the structure. Fiberglass insulation is present wrapped in metal casing;
no mastic was noted. No insulation was observed on two aboveground storage tanks associated with the cooling tower system.
2014 3-Year Reassessment and Update
The Turbine Yard was constructed in 2014 and it has three concrete walls and no roof. This facility is located on the north end of Building 70, the Energy Center.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 3
SECTION II
SECTION II- ASBESTOS LABORATORY ANALYTICAL REPORT
METHODOLOGY
Micro Air of Texas, Inc. performed a comprehensive asbestos survey of Building 70 on March 23 and 24, 2010 and of Building 37 on April 7, 2010 in accordance with AHERA and TAHPA sampling protocol and assessment factors. The inspection was performed by Jennifer McMillin, an accredited asbestos inspector who is licensed as a Building Inspector by the state of Texas (license #60-1893) and Lisa McGarrah, an accredited and state licensed asbestos inspector (license #60-2923). Micro Air of Texas, Inc. is licensed as an Asbestos Consulting Agency (#10-0110). All samples collected during this inspection were analyzed by J3
Resources, Inc., whose laboratory is accredited by the National Institute of Standards and Technology (NIST) under the National Voluntary Laboratory Accreditation Program (NVLAP) program (accreditation #200525-0) and licensed by the state of Texas (license #30-0273).
Laboratory analysis of collected samples was performed in accordance with EPA and NVLAP prescribed methodologies for Polarized Light Microscopy of bulk material samples for the presence of asbestos. The results of laboratory analysis of collected bulk material samples are included in this section for reference.
A total of 128 bulk material samples from Building 70 and six bulk material samples from Building 37 were collected and analyzed by PLM during this comprehensive survey. Federal regulations require that each identifiable layer of an individual bulk building material sample be analyzed separately for asbestos content. In addition, federal regulations state that if any one sample from a homogeneous area is found to be asbestos-containing, then the entire homogeneous area is considered asbestos-containing, regardless of the results from the remaining samples from that homogeneous area.
In 2014, Micro Air conducted a 3-Year Asbestos Reassessment. The Turbine Yard had been added to the north end of Building 70. The Turbine Yard was inspected, and a total of 17 bulk building material samples were collected.
CLASSIFICATION
All materials which were sampled as being suspect for containing asbestos or were assumed to be asbestos-containing were grouped by sample type into Homogeneous Sampling Areas for purposes of assessment and quantification. Homogeneous materials are those which have similar appearance, texture, and function. If the inspector believes these materials to be the same, even if they are located in separate areas of a building, they may be grouped into the same sampling set. For purposes of this inspection report, the Homogeneous Area is designated as : HA. Each Homogeneous Area is given a number to distinguish it from other Homogeneous Areas (Example: HA-01A).
A CAD drawing(s) demonstrating the location of each collected bulk building material sample has been included in this section.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 1
LIMITATIONS
Micro Air’s scope of services was limited primarily to accessible interior building materials.
While Micro Air made every effort to perform a thorough survey, the possibility exists that materials containing asbestos were not identified, inaccessible, or different from those identified at other locations. The findings and opinions presented are indicative of conditions on the date of our site inspection and should not be relied upon to represent conditions at substantially later dates, due to possible changes in the condition of building materials, renovations, and repairs. Additionally, most of the buildings located at this VA facility have steam pipes running underground to supply heat to each building. This material was inaccessible at the time of this inspection. All pipes located in wall chases, underground, in the crawlspace of a building, etc., is assumed to be ACM until tested and proven otherwise.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 2
VAMC - DALLAS, TX
BUILDINGS 70, 37, AND TURBINE YARD
HOMOGENEOUS SAMPLE AREA SUMMARY
THE FOLLOWING TABLES DENOTE THE HOMOGENEOUS AREAS
IDENTIFIED IN BUILDING 70 AND 37. THE TABLES INDICATE THE
NUMBER OF BULK BUILDING MATERIAL SAMPLES COLLECTED FOR EACH
HOMOGENEOUS AREA AND WHETHER THE HOMOGENEOUS AREA WAS
ASBESTOS-CONTAINING. ADDITIONALLY, ESTIMATED QUANTITIES OF
THE VARIOUS BUILDING MATERIALS SAMPLED HAVE ALSO BEEN
INCLUDED IN THE TABLES.
THE TURBINE YARD WAS ADDED TO BUILDING 70 IN 2014, AND IT WAS
INSPECTED FOR ACM. A SEPARATE HOMOGENEOUS AREA TABLE HAS
BEEN INCLUDED IN THIS SECTION FOR THIS PARTICULAR FACILITY.
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 3
VAMC; DALLAS, TX
BUILDING 70
HOMOGENEOUS SAMPLE AREA SUMMARY
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-01 White Paint and White Mastic on Yellow Fiberglass Pipe
Insulation (Steam Piping)
No 3 5,900 LF
HA-02 Tan Paint and White Mastic on
Fiberglass Pipe Insulation (HVAC Piping)
No 3 25,300 LF
HA-03 Gray HVAC Duct Sealant on Metal Duct
No 3 93 SF
HA-04 Light Blue Paint and White Mastic on Fiberglass Pipe
Insulation (Domestic Cold Water Piping)
No 7 2,723 LF
HA-05 Dark Blue Paint and White Mastic on Fiberglass Pipe
Insulation (Feed and Condensate Piping)
No 3 3,500 LF
HA-06 Green Paint and White Mastic on Fiberglass
Pipe Insulation (Make-up Water Piping)
No 7 894 LF
HA-07 White Paint and White Mastic on Fiberglass Pipe Insulation (Hot
Water Supply and Return Piping)
No 4 1,760 LF
HA-08 White Paint and White Mastic on Fiberglass Pipe Insulation (High
Pressure Steam Piping)
No 3 500 LF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 4
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-09 Gray Paint and White Mastic on Fiberglass Pipe Insulation (Roof
Drain)
No 3 800 LF
HA-10 Tan Paint and White Mastic on
Fiberglass Pipe Insulation (HVAC Ducts)
No 3 600 LF
HA-11 Dark Blue Paint and White Mastic on Fiberglass Pipe
Insulation (Chilled Water Piping)
No 5 5,580 LF
HA-12 White Paint and Gray Mastic on Fiberglass
Pipe Insulation (Chilled Water Supply Piping)
No 3 75 LF
HA-13 White Paint and White Mastic on Fiberglass
Pipe Insulation (Chilled Water Return Piping)
No 3 75 LF
HA-14 White Paint and White Mastic on Fiberglass Pipe Insulation (High
Pressure Steam Piping)
No 3 100 LF
HA-15 Chalky Gray Insulation Under Metal Jacket (High
Temperature Steam System)
No 3 1,600 LF
HA-16 Tan Wrap, White/Purple Mastic and Gray Tank
Insulation (Condensate Storage)
No 3 840 SF
HA-17 Tan Paint, White Wrap and Fiberglass Tank
Insulation (Condensate Storage)
No 3 840 SF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 5
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-18 Tan Paint, White Wrap and Gray Tank Insulation
(De-aeration Tank)
No 3 1,080 SF
HA-19 White Paint, White Wrap and Beige Tank
Insulation (Hot Water Recirculation for HVAC)
No 3 3 SF
HA-20 Black Paint and Chalky Gray Insulation with
Mastic (Boilers)
No 3 70 LF
HA-21 Black Paint and Chalky Beige Insulation
(Exhaust System)
No 3 80 LF
HA-22 White Mastic and White Insulation (Boiler Blow
Down)
No 3 45 SF
HA-23 White Mastic on Fiberglass Pipe
Insulation (Condensate Return Tank)
No 3 88 LF
HA-24 12" x 12" White Floor Tile and Black and Yellow
Adhesive
No 6 1,402 SF
HA-25 Sheet Rock, Texture, Tape & Joint Compound
No 12 21,594 SF
HA-26 Yellow Cove Base Adhesive
No 4 557 LF
HA-27 4' x 2' White Ceiling Tile (Type I)
No 3 1,900 SF
HA-28 2' x 2' White Ceiling Tile (Type II)
No 3 220 SF
HA-29 Gray Sink Soundproofing No 1 4 SF
HA-30 Green Gasket Material No 3 50 SF
HA-31 Red Gasket Material No 3 25 SF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 6
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-32 White Gasket Material (Rope Type Material)
No 3 96 LF
HA-33 Gray Gasket Material No 3 25 SF
HA-34 Green Gasket Material No 1 25 SF
HA-35 Red Gasket Material No 2 25 SF
HA-36 Red Fire Stop No 4 40 SF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 7
VAMC; DALLAS, TX
BUILDING 37
HOMOGENEOUS SAMPLE AREA SUMMARY
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-01 Gray Slat Material No 3 90,000 SF
HA-02 Gray Slat Material No 3 90,000 SF
VAMC; DALLAS, TX
TURBINE YARD
HOMOGENEOUS SAMPLE AREA SUMMARY
Homogeneous Area #
Sample Type Asbestos-containing
# of Samples Collected
Est.
Quantity
HA-01 Fiberglass pipe insulation with white mastic, green paint, & paper wrap on glycol water return line
No 3 100 LF
HA-02 Fiberglass pipe insulation with white mastic & paper wrap on chilled water supply & return lines
No 5 200 LF
HA-03 Fiberglass pipe insulation with white mastic & paper wrap high pressure steam lines
No
2 200 LF
HA-04 White rope gasket on unit door
No 2 5 LF
HA-05 Fiberglass Insulation No 3 200 SF
HA-06 Gray Caulk on Mud Drum No 2 25 LF
MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 8
Date Received: 29-Mar-2010 01-Apr-2010Date Analyzed:
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose Fiber Wollastonite
NoGasket, Green, Homogeneous None Detected70-01 5% 4%
Other Non-Fibrous Material 91%
Cellulose Fiber Wollastonite
NoGasket, Green, Homogeneous None Detected70-02 5% 4%
Other Non-Fibrous Material 91%
Cellulose Fiber Wollastonite
NoGasket, Green, Homogeneous None Detected70-03 5% 4%
Other Non-Fibrous Material 91%
Cellulose Fiber Wollastonite
NoLAYER 1 Mastic, White, Homogeneous
None Detected70-04 3% 2%
Other Non-Fibrous Material 95%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 1 of 33
Lab DirectorLee W. Poye
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose Fiber Wollastonite
NoLAYER 1 Mastic, White, Homogeneous
None Detected70-05 3% 2%
Other Non-Fibrous Material 95%
NoLAYER 2 Mastic, Tan, Homogeneous
None Detected Other Non-Fibrous Material 100%
Fibrous GlassNoLAYER 3 Insulation, Yellow, Homogeneous
None Detected 100%
Cellulose Fiber Wollastonite
NoLAYER 1 Mastic, White, Homogeneous
None Detected70-06 3% 2%
Other Non-Fibrous Material 95%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Cellulose Fiber Fibrous Glass
NoInsulation, Gray/ Beige, Homogeneous
None Detected70-07 5% 5%
Other Non-Fibrous Material 90%
Cellulose Fiber Fibrous Glass
NoInsulation, Gray/ Beige, Homogeneous
None Detected70-08 5% 5%
Other Non-Fibrous Material 90%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 2 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose Fiber Fibrous Glass
NoInsulation, Beige, Homogeneous None Detected70-09 5% 5%
Other Non-Fibrous Material 90%
Cellulose FiberNoLAYER 1 Wrap, Brown/ Beige, Homogeneous
None Detected70-10 75%
Other Non-Fibrous Material 25%
Cellulose Fiber Fibrous Glass
NoLAYER 2 Mastic Wrap, Purple/ White, Homogeneous
None Detected 25% 10%
Other Non-Fibrous Material 65%
Cellulose Fiber Fibrous Glass
NoLAYER 3 Insulation, Gray, Homogeneous
None Detected 5% 5%
Other Non-Fibrous Material 90%
Cellulose FiberNoLAYER 1 Wrap, Brown/ Beige, Homogeneous
None Detected70-11 75%
Other Non-Fibrous Material 25%
Cellulose Fiber Fibrous Glass
NoLAYER 2 Mastic Wrap, Purple/ White, Homogeneous
None Detected 25% 10%
Other Non-Fibrous Material 65%
Cellulose Fiber Fibrous Glass
NoLAYER 3 Insulation, Gray, Homogeneous
None Detected 5% 5%
Other Non-Fibrous Material 90%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 3 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose FiberNoLAYER 1 Wrap, Brown/ Beige, Homogeneous
None Detected70-12 75%
Other Non-Fibrous Material 25%
Cellulose Fiber Fibrous Glass
NoLAYER 2 Mastic Wrap, Purple/ White, Homogeneous
None Detected 25% 10%
Other Non-Fibrous Material 65%
Cellulose Fiber Fibrous Glass
NoLAYER 3 Insulation, Gray, Homogeneous
None Detected 5% 5%
Other Non-Fibrous Material 90%
Cellulose FiberNoLAYER 1 Wrap, Brown/ White, Homogeneous
None Detected70-13 75%
Other Non-Fibrous Material 25%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Cellulose FiberNoLAYER 1 Wrap, Brown/ White, Homogeneous
None Detected70-14 75%
Other Non-Fibrous Material 25%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 4 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose FiberNoLAYER 1 Wrap, Brown/ White, Homogeneous
None Detected70-15 75%
Other Non-Fibrous Material 25%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Cellulose Fiber Fibrous Glass
NoLAYER 1 Wrap, Tan/ White, Homogeneous
None Detected70-16 2% 5%
Other Non-Fibrous Material 93%
Cellulose Fiber Synthetic Fiber
NoLAYER 2 Insulation, Gray, Homogeneous
None Detected 5% 15%
Other Non-Fibrous Material 80%
Cellulose Fiber Fibrous Glass
NoLAYER 1 Wrap, Tan/ White, Homogeneous
None Detected70-17 2% 5%
Other Non-Fibrous Material 93%
Cellulose Fiber Synthetic Fiber
NoLAYER 2 Insulation, Gray, Homogeneous
None Detected 5% 15%
Other Non-Fibrous Material 80%
Synthetic FiberNoLAYER 3 Insulation, Beige, Homogeneous
None Detected 15%
Other Non-Fibrous Material 85%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 5 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose Fiber Fibrous Glass
NoLAYER 1 Wrap, Tan/ White, Homogeneous
None Detected70-18 2% 5%
Other Non-Fibrous Material 93%
Cellulose Fiber Synthetic Fiber
NoLAYER 2 Insulation, Gray, Homogeneous
None Detected 5% 15%
Other Non-Fibrous Material 80%
Synthetic FiberNoLAYER 3 Insulation, Beige, Homogeneous
None Detected 15%
Other Non-Fibrous Material 85%
Cellulose Fiber Synthetic Fiber
NoInsulation, White/ Beige, Homogeneous
None Detected70-19 5% 15%
Other Non-Fibrous Material 80%
Cellulose FiberNoLAYER 1 Mastic Wrap, White, Homogeneous
None Detected70-20 5%
Other Non-Fibrous Material 95%
Cellulose Fiber Synthetic Fiber
NoLAYER 2 Insulation, Beige, Homogeneous
None Detected 5% 15%
Other Non-Fibrous Material 80%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 6 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose FiberNoLAYER 1 Mastic Wrap, White, Homogeneous
None Detected70-21 5%
Other Non-Fibrous Material 95%
Cellulose Fiber Synthetic Fiber
NoLAYER 2 Insulation, Beige, Homogeneous
None Detected 5% 15%
Other Non-Fibrous Material 80%
Cellulose FiberNoGasket, Red, Homogeneous None Detected70-22 5%
Other Non-Fibrous Material 95%
Cellulose FiberNoGasket, Red, Homogeneous None Detected70-23 5%
Other Non-Fibrous Material 95%
Cellulose FiberNoGasket, Red, Homogeneous None Detected70-24 5%
Other Non-Fibrous Material 95%
Cellulose Fiber Fibrous Glass
NoLAYER 1 Mastic Wrap, Brown/ White, Homogeneous
None Detected70-25 10% 10%
Other Non-Fibrous Material 80%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 7 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose Fiber Fibrous Glass
NoLAYER 1 Mastic Wrap, Brown/ White, Homogeneous
None Detected70-26 10% 10%
Other Non-Fibrous Material 80%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Cellulose Fiber Fibrous Glass
NoLAYER 1 Mastic Wrap, Brown/ White, Homogeneous
None Detected70-27 10% 10%
Other Non-Fibrous Material 80%
Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous
None Detected 100%
Fibrous GlassNoGasket, White, Homogeneous None Detected70-28 100%
Fibrous GlassNoGasket, White, Homogeneous None Detected70-29 100%
Fibrous GlassNoGasket, White, Homogeneous None Detected70-30 100%
NoSink Soundproof, Gray/ Brown, Homogeneous
None Detected70-31 Other Non-Fibrous Material 100%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 8 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
Cellulose Fiber Fibrous Glass
NoCeiling Tile, White/ Gray, Homogeneous
None Detected70-32 45% 10%
Other Non-Fibrous Material 45%
Cellulose Fiber Fibrous Glass
NoCeiling Tile, White/ Gray, Homogeneous
None Detected70-33 45% 10%
Other Non-Fibrous Material 45%
Cellulose Fiber Fibrous Glass
NoCeiling Tile, White/ Gray, Homogeneous
None Detected70-34 45% 10%
Other Non-Fibrous Material 45%
Cellulose Fiber Fibrous Glass
NoCeiling Tile, White/ Gray, Homogeneous
None Detected70-35 45% 10%
Other Non-Fibrous Material 45%
Cellulose Fiber Fibrous Glass
NoCeiling Tile, White/ Gray, Homogeneous
None Detected70-36 45% 10%
Other Non-Fibrous Material 45%
Cellulose Fiber Fibrous Glass
NoCeiling Tile, White/ Gray, Homogeneous
None Detected70-37 45% 10%
Other Non-Fibrous Material 45%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 9 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
NoLAYER 1 Floor Tile, White, Homogeneous
None Detected70-38 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Mastic, Black/ Yellow, Homogeneous
None Detected 3%
Other Non-Fibrous Material 97%
NoLAYER 1 Floor Tile, White, Homogeneous
None Detected70-39 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Mastic, Black/ Yellow, Homogeneous
None Detected 3%
Other Non-Fibrous Material 97%
NoLAYER 1 Floor Tile, White, Homogeneous
None Detected70-40 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Mastic, Black/ Yellow, Homogeneous
None Detected 3%
Other Non-Fibrous Material 97%
NoLAYER 1 Floor Tile, White, Homogeneous
None Detected70-41 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Mastic, Black, Homogeneous
None Detected 3%
Other Non-Fibrous Material 97%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 10 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
NoLAYER 1 Floor Tile, White, Homogeneous
None Detected70-42 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Mastic, Black, Homogeneous
None Detected 3%
Other Non-Fibrous Material 97%
NoLAYER 1 Floor Tile, White, Homogeneous
None Detected70-43 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Mastic, Black, Homogeneous
None Detected 3%
Other Non-Fibrous Material 97%
NoMastic, Gray, Homogeneous None Detected70-44 Other Non-Fibrous Material 100%
NoMastic, Gray, Homogeneous None Detected70-45 Other Non-Fibrous Material 100%
NoMastic, Gray, Homogeneous None Detected70-46 Other Non-Fibrous Material 100%
NoMastic, Yellow, Homogeneous None Detected70-47 Other Non-Fibrous Material 100%
NoMastic, Yellow, Homogeneous None Detected70-48 Other Non-Fibrous Material 100%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 11 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
NoMastic, Yellow, Homogeneous None Detected70-49 Other Non-Fibrous Material 100%
NoMastic, Yellow, Homogeneous None Detected70-50 Other Non-Fibrous Material 100%
NoLAYER 1 Texture, White, Homogeneous
None Detected70-51 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Tape, White, Homogeneous
None Detected 100%
NoLAYER 3 Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10% <1%
Other Non-Fibrous Material 90%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 12 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
NoLAYER 1 Texture, White, Homogeneous
None Detected70-52 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Tape, White, Homogeneous
None Detected 100%
NoLAYER 3 Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10% <1%
Other Non-Fibrous Material 90%
NoLAYER 1 Texture, White, Homogeneous
None Detected70-53 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Tape, White, Homogeneous
None Detected 100%
NoLAYER 3 Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 4 Wallboard, Brown/ White, Homogeneous
None Detected 10% <1%
Other Non-Fibrous Material 90%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 13 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
NoLAYER 1 Texture, White, Homogeneous
None Detected70-54 Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 2 Wallboard, Brown/ White, Homogeneous
None Detected 10% <1%
Other Non-Fibrous Material 90%
NoLAYER 1 Texture, White, Homogeneous
None Detected70-55 Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 2 Wallboard, Brown/ White, Homogeneous
None Detected 10% <1%
Other Non-Fibrous Material 90%
NoLAYER 1 Painted Texture, Pink/ White, Homogeneous
None Detected70-56 Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 2 Wallboard, Brown/ White, Homogeneous
None Detected 10% <1%
Other Non-Fibrous Material 90%
Eric Montoya Analyst
This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 14 of 33
JH1033000J3 Order #:
VAMC - BLDG 70
1052 Hercules Drive Houston TX 77058
Micro Air of Texas Melissa Kiser
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)
EPA 600/M4-82-020; 600/R-93/116
Asbestos (Yes/No)
Sample Description Asbestos Constituents
Sample ID # Location Non-Asbestos Constituents
J3 Resources, Inc.
6110 W. 34th Street, Houston, Texas 77092
Phone: (713) 290-0221 - Fax: (713) 290-0248
J3Resources.com
02-Apr-2010Date Reported:
NoLAYER 1 Painted Texture, White, Homogeneous
None Detected70-57 Other Non-Fibrous Material 100%
Cellulose FiberNoLAYER 2 Tape, White, Homogeneous
None Detected 100%
NoLAYER 3 Joint Compound, White, Homogeneous
None Detected Other Non-Fibrous Material 100%
Cellulose Fiber Fibrous Glass
NoLAYER 4 Wallboard,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .