Bldg70Insp MgmtPlan3YearUpdate2014.pdf

PDF 13 MB Posted

Attached to
36C25726B0001 | 549-23-601 Upgrade Chillers and Cooling Towers Energy at Energy Center
Solicitation number
36C25726B0001
Issued by

About this file

This is an AHERA (Asbestos Hazard Emergency Response Act) Asbestos Inspection & Management Plan for the VA Medical Center Dallas, Texas, specifically covering Buildings 70, 37, and the Turbine Yard. The document reports on comprehensive asbestos surveys conducted in March and April 2010, with a three-year reassessment completed in June 2014. Buildings 70 and 37, constructed in 1994, comprise approximately 34,726 square feet and serve as the Energy Center and Air Conditioning Cooling Tower facility, respectively. The inspection was performed by Micro Air of Texas, Inc., with accredited inspectors Jennifer McMillin and Lisa McGarrah holding valid Texas DSHS licenses. Laboratory analysis by J3 Resources, Inc., an NIST-accredited facility, examined 128 bulk samples from Building 70, 6 samples from Building 37, and 17 samples from the newly constructed Turbine Yard using Polarized Light Microscopy (PLM) methodology in accordance with EPA standards.

The management plan documents material assessments across 36 homogeneous sampling areas (HA-01 through HA-36) in Building 70, 2 areas in Building 37, and 6 areas in the Turbine Yard, encompassing various materials including thermal system insulation (colored and painted fiberglass pipe insulation with mastics), floor tiles, ceiling tiles, gaskets, and duct sealants. Notably, all laboratory analysis results indicate that none of the tested materials contain asbestos (all samples reported "No" for asbestos content). The document specifies that designated persons Thomas Rattler or Ken Taylor are responsible for implementation of the management plan, with engineering contact Charles Ballard at 214-857-1069. The plan includes provisions for Operations & Maintenance programs, six-month surveillance documentation, and three-year reinspection schedules as required under AHERA and TAHPA protocols, with no immediate response actions recommended given the absence of asbestos-containing materials.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA MEDICAL CENTER

DALLAS, TEXAS

BUILDINGS 70, 37, & TURBINE YARD

A.H.E.R.A. ASBESTOS INSPECTION

MANAGEMENT PLAN

3 - YEAR REASSESSMENT & UPDATE - 2014

PREPARED FOR:

VA NORTH TEXAS HEALTH CARE SYSTEM

ENGINEERING SERVICES

4500 S. LANCASTER ROAD

DALLAS, TX 75216

MICRO AIR PROJECT #B-1403

PREPARED BY:

MICRO AIR OF TEXAS, INC.

P.O. Box 1225 Dickinson, TX 77539

(281) 280-9965

DALLAS, TEXAS

AHERA

ASBESTOS INSPECTION

PREPARED FOR:

VA NORTH TEXAS HEALTH CARE SYSTEM

ENGINEERING SERVICES

4500 S. LANCASTER ROAD

DALLAS, TX 75216

PREPARED BY:

MICRO AIR OF TEXAS, INC.

P.O. Box 1225 Dickinson, TX 77539

(281) 280-9965

Inspection Dates: March 23 and 24, 2010 and April 7, 2010

Individual Asbestos Consultant: ________________________

DSHS License # 10-5436

TABLE OF CONTENTS

Page #

General Inventory Management Plan Format

Section I - AHERA Asbestos Inspection General Information

Introduction, Required Information, & Facility Description 1 - 3

Section II - Asbestos Methodology & Lab Analytical Report

Methodology 1 Classification 1 Limitations 2 Homogeneous Sampling Area Summary Table 3 - 8 Laboratory Report Sample Location Drawing(s)

Section III - ACM Material Assessment & Quantification

General Information 1 Building 70 Surfacing Materials 2 Thermal System Insulation Materials 2 - 11 Miscellaneous Materials 12 - 16 Building 37 Surfacing Materials 17 Thermal System Insulation Materials 17 Miscellaneous Materials 17 - 18 Turbine Yard 19 Surfacing Materials 19 Thermal System Insulation Materials 19 - 21 Miscellaneous Materials 21

Section IV - Asbestos Material Response Action Recommendations

This Section is Not Applicable 1

Section V - Operations & Maintenance Program

Purpose / This Section is Not Applicable 1

Section VI - Facility Owner / Designated Person(s)

Licenses and Training Certificates

Section VII - Six Month Surveillance Documentation - Not Applicable

Section VIII - Three Year Reinspection Updates / Schedule

Section IX - Response Actions - Not Applicable

BUILDING INSPECTION FOR FRIABLE AND NON-FRIABLE ACM

GENERAL INVENTORY

FACILITY ID: Buildings 70, 37, and Turbine Yard

ORIGINAL INSPECTION COMPLETION DATES BLDG 70 & 37: March 23 and 24, 2010 and April 7, 2010

ORIGINAL INSPECTION COMPLETION DATE FOR TURBINE BUILDING: June 10, 2014 3-YEAR REASSESSMENT INSPECTION COMPLETION DATE: June 10, 2014

FACILITY ADDRESS: Buildings 70 and 37

VAMC

4500 S. Lancaster Rd.

Dallas, TX 75216

TOTAL SQUARE FOOTAGE: APPROXIMATELY 34,726 Square Feet

YEAR CONSTRUCTED: 1994

USE OF FACILITY: Energy Center (Building 70) and Air Conditioning Cooling Tower (Building 37) and Turbine Yard

DESIGNATED PERSON: Thomas Rattler or Ken Taylor

ENGINEERING PHONE: 214-857-1069 - Contact Charles Ballard

INSPECTION COMPANY: MICRO AIR OF TEXAS, INC.

P.O. Box 1225 Dickinson, TX 77539

PHONE: (281) 280-9965

NAME OF ACCREDITED PERSON

PERFORMING INSPECTION: JENNIFER MCMILLIN (DSHS LICENCE # 60-1893)

LISA MCGARRAH (DSHS LICENSE # 60-2923)

ACCREDITATION AGENCY: TEXAS DEPT. OF STATE HEALTH SERVICES

ACCREDITATION #: N/A

THIS BUILDING CONTAINS:

1. FRIABLE ACBM

2. NON-FRIABLE ACBM

3. FRIABLE MATERIAL

(ASSUMED TO BE ACBM)

4. NON-FRIABLE MATERIAL

(ASSUMED TO BE ACBM)

5. NONE OF THE ABOVE X

______________________________________ 5/21/10 & 6/10/14

ACCREDITED INSPECTOR DATE

DSHS LICENSE # 60-1893

_______________________________________ 5/21/10

ACCREDITED INSPECTOR DATE

DSHS LICENSE # 60-2923

BUILDINGS 70, 37, & TURBINE YARD

DALLAS, TX

A.H.E.R.A. ASBESTOS INSPECTION &

MANAGEMENT PLAN

PREPARED FOR:

VA NORTH TEXAS HEALTH CARE SYSTEM

ENGINEERING SERVICES

4500 S. LANCASTER ROAD

DALLAS, TX 75216

MICRO AIR PROJECT #B-1403

PREPARED BY:

MICRO AIR OF TEXAS, INC.

P.O. Box 1225

MICRO AIR OF TEXAS, INC. BUILDINGS 70, 37, & Turbine Yard - VA Medical Center; Dallas, TX

AHERA ASBESTOS INSPECTION & MANAGEMENT PLAN

P.O. Box 1225

MANAGEMENT PLAN FORMAT

SECTION I: This section contains general information regarding the AHERA survey and management plan, required information, and a facility description.

SECTION II: This section contains general information, sampling information, and Homogeneous Sample Area Summary. The laboratory analytical report for the bulk samples collected during the 2010 inspection has been included. Additionally, information on the survey report and classification of homogeneous areas is located in this section. Drawings depicting the locations of all bulk building material samples collected and asbestos-containing homogeneous area locations can be found in this sub-section.

SECTION III: This section contains material assessments and quantification which are used to develop the appropriate response actions for the management plan. Photographs of each asbestos-containing material identified has been included in this section.

SECTION IV: This section contains the recommended response actions for each type of ACM in the facility including recommendations for immediate abatement, if necessary. Immediate response action recommendations are prioritized.

SECTION V: This section contains an updated Operations and Maintenance Program for the facility.

This program includes recommendations for ongoing maintenance functions.

SECTION VI: This section has been reserved for informational purposes. This section includes the Facility Owner / Designated Person information, as well as the Re-inspection / Periodic Surveillance Schedule. All applicable licenses, certifications, and accreditations of the Inspector, Management Planner, and Laboratory performing services on this Management Plan are also included in this section.

SECTION VII: This section has been reserved for reports for the six month inspections, assessments, and any ambient air monitoring.

SECTION VIII: This section has been reserved for documentation obtained from three year re-inspections. Updates to the Management Plan are to be included in this section.

SECTION IX: This section has been reserved for the owner to reference abatement response action reports and building maintenance action (O&M) reports. All documentation from asbestos abatement activities should also be included in this section.

SECTION I

AHERA ASBESTOS INSPECTION

SECTION I - GENERAL INFORMATION

INTRODUCTION

Micro Air of Texas, Inc. (Micro Air) was contracted by the Veterans Administration North Texas Health Care System (VANTHCS) located in Dallas, Texas to perform an asbestos inspection and generate a management plan in accordance with guidelines established in 40 CFR 763, the Asbestos Hazard Emergency Response Act of 1987 (AHERA), for the aforementioned facility located in Dallas, Texas. This facility consists of numerous buildings constructed between 1940 and 2009. This particular report pertains to Buildings 70 and 37. Building 70 is the Energy Center; Building 37 is the Air Conditioning Cooling Tower located behind the Energy Center. Based on information we obtained from VA personnel, Buildings 70 and 37 were constructed in 1994.

During the 2014 3-Year Asbestos Assessment and Re-inspection, Micro Air noted that the Turbine Yard had been added to the north end of the Energy Center. Construction of this area was completed in 2014. Micro Air conducted an asbestos inspection on the Turbine Yard and the north end of the Building 70 where new pipe insulation had been installed as part of the construction of the Turbine Yard. A total of 17 bulk building material samples were collected in June, 2014, and the results were included in this management plan.

Micro Air performed a comprehensive asbestos survey of Building 70 on March 23 and 24, 2010; the comprehensive asbestos survey of Building 37 (Cooling Tower) was completed on April 7, 2010. After the comprehensive asbestos survey results were compiled, a Management Planner accredited by an EPA-approved training provider and licensed as an Individual Asbestos Consultant in the state of Texas, reviewed the analytical results of the inspection and current physical condition assessments. The management planner then determined the potential hazard posed by the ACM and evaluated and selected control / response options based on all compiled information. This information was then composed and written into a final report.

The federal National Emission Standard for Asbestos (NESHAP) and the Texas Asbestos Health Protection Act (TAHPA) both require that prior to any demolition or renovation activity in a building, a thorough inspection of the affected facility or part of the facility where the demolition or renovation operation will occur, must be performed for the presence of asbestos, including Category I and Category II non-friable asbestos-containing material (ACM).

Additionally, TAHPA requires that a minimum of three samples be collected from each homogeneous sampling area (material type) identified in the building. The work area and immediately surrounding areas which could foreseeably be disturbed by the actions necessary to perform the project must be inspected and sampled as applicable prior to renovations or demolition. While the VANTHCS is not subject to the TAHPA regulation, due to its exclusion as a federal facility, Micro Air collected bulk samples in accordance with TAHPA and AHERA protocol at the request of the VANTHCS engineering personnel.

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 1

REQUIRED INFORMATION

In accordance with AHERA protocol, the VAMC located in Dallas, Texas is required to name a person who shall be responsible for implementation of the management plan (Designated Person - see Section V). Per the Occupational Safety and Health Administration (OSHA) 1926.1101, construction industry standard, maintenance personnel should be made aware of the types and locations of all facility ACM. These employees are required to have adequate asbestos awareness training (minimum 2 hours), and all maintenance personnel who may come in contact with or disturb ACM are required to receive a minimum of 16 hours of asbestos training in asbestos hazards and recognition of ACM. If the owner wishes to perform ACM activities with its own personnel, the owner is responsible for obtaining the required EPA training in accordance with the Model Accreditation Plan (MAP), which is located in Appendix C, Subpart E of 40 CFR, 763 (AHERA). Additionally, all OSHA requirements must be met, as well (i.e., asbestos physical, etc.). Otherwise, it is recommended that all ACM activities be performed by a Texas licensed Asbestos Contractor, and project oversight be conducted by a Texas licensed Asbestos Consultant Agency.

In accordance with the VA directive to comply with AHERA, the entire facility must be re-inspected and a reassessment of ACM conducted by an accredited inspector at least once every three years, and the management plan should be updated by a licensed Asbestos Inspector / Management Planner or Individual Asbestos Consultant. Additionally, visual inspections of the ACM must also be made by the Designated Person for the facility at least once every six months to determine whether any areas of the material have changed in condition, or if there are any other factors which may necessitate abatement actions.

FACILITY DESCRIPTION

Building 70 is an approximately 34,726 square foot, two-story structure (one floor and elevated catwalk areas), and currently serves as the Energy Center at the Dallas VA. The construction date of this building is believed to be 1994. The interior finish materials consist primarily of concrete floors with CMU block walls and unfinished ceilings. Office areas and hallways are finished with 12 inch by 12 inch vinyl floor tile, ceramic tile, 18 inch by 18 inch plastic tiles in a metal frame raised approximately one foot above the concrete floor, and carpet. Sheet rock walls with painted texture and lay-in ceilings (two foot by four foot and two foot by two foot ceiling tiles) are present in the office areas and hallways.

Several types of color-coded insulated piping systems are present in the plant areas (Rooms 106 and 107) and tunnel entrance. Insulated piping is primarily fiberglass with PVC joints.

Four boilers were observed in Room 106. Six chillers are present in Room 107. Vibrations joints associated with the HVAC system were rubber.

The exterior of the Energy Building is tilt-up concrete panels and a flat, tar and gravel roof.

The Air Conditioning Cooling Tower (Building 37) is located behind the Energy Center. The cooling tower includes six cells (one for each chiller), and is a metal structure with metal brackets on concrete footings. Fiberglass slats were observed inside the cooling tower cells.

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 2

Rubber matts are located at the base of the structure and rubber gaskets were observed on metal piping outside of the structure. Fiberglass insulation is present wrapped in metal casing;

no mastic was noted. No insulation was observed on two aboveground storage tanks associated with the cooling tower system.

2014 3-Year Reassessment and Update

The Turbine Yard was constructed in 2014 and it has three concrete walls and no roof. This facility is located on the north end of Building 70, the Energy Center.

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 3

SECTION II

SECTION II- ASBESTOS LABORATORY ANALYTICAL REPORT

METHODOLOGY

Micro Air of Texas, Inc. performed a comprehensive asbestos survey of Building 70 on March 23 and 24, 2010 and of Building 37 on April 7, 2010 in accordance with AHERA and TAHPA sampling protocol and assessment factors. The inspection was performed by Jennifer McMillin, an accredited asbestos inspector who is licensed as a Building Inspector by the state of Texas (license #60-1893) and Lisa McGarrah, an accredited and state licensed asbestos inspector (license #60-2923). Micro Air of Texas, Inc. is licensed as an Asbestos Consulting Agency (#10-0110). All samples collected during this inspection were analyzed by J3

Resources, Inc., whose laboratory is accredited by the National Institute of Standards and Technology (NIST) under the National Voluntary Laboratory Accreditation Program (NVLAP) program (accreditation #200525-0) and licensed by the state of Texas (license #30-0273).

Laboratory analysis of collected samples was performed in accordance with EPA and NVLAP prescribed methodologies for Polarized Light Microscopy of bulk material samples for the presence of asbestos. The results of laboratory analysis of collected bulk material samples are included in this section for reference.

A total of 128 bulk material samples from Building 70 and six bulk material samples from Building 37 were collected and analyzed by PLM during this comprehensive survey. Federal regulations require that each identifiable layer of an individual bulk building material sample be analyzed separately for asbestos content. In addition, federal regulations state that if any one sample from a homogeneous area is found to be asbestos-containing, then the entire homogeneous area is considered asbestos-containing, regardless of the results from the remaining samples from that homogeneous area.

In 2014, Micro Air conducted a 3-Year Asbestos Reassessment. The Turbine Yard had been added to the north end of Building 70. The Turbine Yard was inspected, and a total of 17 bulk building material samples were collected.

CLASSIFICATION

All materials which were sampled as being suspect for containing asbestos or were assumed to be asbestos-containing were grouped by sample type into Homogeneous Sampling Areas for purposes of assessment and quantification. Homogeneous materials are those which have similar appearance, texture, and function. If the inspector believes these materials to be the same, even if they are located in separate areas of a building, they may be grouped into the same sampling set. For purposes of this inspection report, the Homogeneous Area is designated as : HA. Each Homogeneous Area is given a number to distinguish it from other Homogeneous Areas (Example: HA-01A).

A CAD drawing(s) demonstrating the location of each collected bulk building material sample has been included in this section.

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 1

LIMITATIONS

Micro Air’s scope of services was limited primarily to accessible interior building materials.

While Micro Air made every effort to perform a thorough survey, the possibility exists that materials containing asbestos were not identified, inaccessible, or different from those identified at other locations. The findings and opinions presented are indicative of conditions on the date of our site inspection and should not be relied upon to represent conditions at substantially later dates, due to possible changes in the condition of building materials, renovations, and repairs. Additionally, most of the buildings located at this VA facility have steam pipes running underground to supply heat to each building. This material was inaccessible at the time of this inspection. All pipes located in wall chases, underground, in the crawlspace of a building, etc., is assumed to be ACM until tested and proven otherwise.

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 2

VAMC - DALLAS, TX

BUILDINGS 70, 37, AND TURBINE YARD

HOMOGENEOUS SAMPLE AREA SUMMARY

THE FOLLOWING TABLES DENOTE THE HOMOGENEOUS AREAS

IDENTIFIED IN BUILDING 70 AND 37. THE TABLES INDICATE THE

NUMBER OF BULK BUILDING MATERIAL SAMPLES COLLECTED FOR EACH

HOMOGENEOUS AREA AND WHETHER THE HOMOGENEOUS AREA WAS

ASBESTOS-CONTAINING. ADDITIONALLY, ESTIMATED QUANTITIES OF

THE VARIOUS BUILDING MATERIALS SAMPLED HAVE ALSO BEEN

INCLUDED IN THE TABLES.

THE TURBINE YARD WAS ADDED TO BUILDING 70 IN 2014, AND IT WAS

INSPECTED FOR ACM. A SEPARATE HOMOGENEOUS AREA TABLE HAS

BEEN INCLUDED IN THIS SECTION FOR THIS PARTICULAR FACILITY.

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 3

VAMC; DALLAS, TX

BUILDING 70

HOMOGENEOUS SAMPLE AREA SUMMARY

Homogeneous Area #

Sample Type Asbestos-containing

# of Samples Collected

Est.

Quantity

HA-01 White Paint and White Mastic on Yellow Fiberglass Pipe

Insulation (Steam Piping)

No 3 5,900 LF

HA-02 Tan Paint and White Mastic on

Fiberglass Pipe Insulation (HVAC Piping)

No 3 25,300 LF

HA-03 Gray HVAC Duct Sealant on Metal Duct

No 3 93 SF

HA-04 Light Blue Paint and White Mastic on Fiberglass Pipe

Insulation (Domestic Cold Water Piping)

No 7 2,723 LF

HA-05 Dark Blue Paint and White Mastic on Fiberglass Pipe

Insulation (Feed and Condensate Piping)

No 3 3,500 LF

HA-06 Green Paint and White Mastic on Fiberglass

Pipe Insulation (Make-up Water Piping)

No 7 894 LF

HA-07 White Paint and White Mastic on Fiberglass Pipe Insulation (Hot

Water Supply and Return Piping)

No 4 1,760 LF

HA-08 White Paint and White Mastic on Fiberglass Pipe Insulation (High

Pressure Steam Piping)

No 3 500 LF

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 4

Homogeneous Area #

Sample Type Asbestos-containing

# of Samples Collected

Est.

Quantity

HA-09 Gray Paint and White Mastic on Fiberglass Pipe Insulation (Roof

Drain)

No 3 800 LF

HA-10 Tan Paint and White Mastic on

Fiberglass Pipe Insulation (HVAC Ducts)

No 3 600 LF

HA-11 Dark Blue Paint and White Mastic on Fiberglass Pipe

Insulation (Chilled Water Piping)

No 5 5,580 LF

HA-12 White Paint and Gray Mastic on Fiberglass

Pipe Insulation (Chilled Water Supply Piping)

No 3 75 LF

HA-13 White Paint and White Mastic on Fiberglass

Pipe Insulation (Chilled Water Return Piping)

No 3 75 LF

HA-14 White Paint and White Mastic on Fiberglass Pipe Insulation (High

Pressure Steam Piping)

No 3 100 LF

HA-15 Chalky Gray Insulation Under Metal Jacket (High

Temperature Steam System)

No 3 1,600 LF

HA-16 Tan Wrap, White/Purple Mastic and Gray Tank

Insulation (Condensate Storage)

No 3 840 SF

HA-17 Tan Paint, White Wrap and Fiberglass Tank

Insulation (Condensate Storage)

No 3 840 SF

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 5

Sample Type Asbestos-containing

# of Samples Collected

Est.

Quantity

HA-18 Tan Paint, White Wrap and Gray Tank Insulation

(De-aeration Tank)

No 3 1,080 SF

HA-19 White Paint, White Wrap and Beige Tank

Insulation (Hot Water Recirculation for HVAC)

No 3 3 SF

HA-20 Black Paint and Chalky Gray Insulation with

Mastic (Boilers)

No 3 70 LF

HA-21 Black Paint and Chalky Beige Insulation

(Exhaust System)

No 3 80 LF

HA-22 White Mastic and White Insulation (Boiler Blow

Down)

No 3 45 SF

HA-23 White Mastic on Fiberglass Pipe

Insulation (Condensate Return Tank)

No 3 88 LF

HA-24 12" x 12" White Floor Tile and Black and Yellow

Adhesive

No 6 1,402 SF

HA-25 Sheet Rock, Texture, Tape & Joint Compound

No 12 21,594 SF

HA-26 Yellow Cove Base Adhesive

No 4 557 LF

HA-27 4' x 2' White Ceiling Tile (Type I)

No 3 1,900 SF

HA-28 2' x 2' White Ceiling Tile (Type II)

No 3 220 SF

HA-29 Gray Sink Soundproofing No 1 4 SF

HA-30 Green Gasket Material No 3 50 SF

HA-31 Red Gasket Material No 3 25 SF

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 6

Sample Type Asbestos-containing

# of Samples Collected

Est.

Quantity

HA-32 White Gasket Material (Rope Type Material)

No 3 96 LF

HA-33 Gray Gasket Material No 3 25 SF

HA-34 Green Gasket Material No 1 25 SF

HA-35 Red Gasket Material No 2 25 SF

HA-36 Red Fire Stop No 4 40 SF

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 7

VAMC; DALLAS, TX

BUILDING 37

HOMOGENEOUS SAMPLE AREA SUMMARY

Homogeneous Area #

Sample Type Asbestos-containing

# of Samples Collected

Est.

Quantity

HA-01 Gray Slat Material No 3 90,000 SF

HA-02 Gray Slat Material No 3 90,000 SF

VAMC; DALLAS, TX

TURBINE YARD

HOMOGENEOUS SAMPLE AREA SUMMARY

Homogeneous Area #

Sample Type Asbestos-containing

# of Samples Collected

Est.

Quantity

HA-01 Fiberglass pipe insulation with white mastic, green paint, & paper wrap on glycol water return line

No 3 100 LF

HA-02 Fiberglass pipe insulation with white mastic & paper wrap on chilled water supply & return lines

No 5 200 LF

HA-03 Fiberglass pipe insulation with white mastic & paper wrap high pressure steam lines

No

2 200 LF

HA-04 White rope gasket on unit door

No 2 5 LF

HA-05 Fiberglass Insulation No 3 200 SF

HA-06 Gray Caulk on Mud Drum No 2 25 LF

MICRO AIR OF TEXAS, INC. VAMC; Dallas, Texas - Buildings 70, 37, & Turbine Yard 8

Date Received: 29-Mar-2010 01-Apr-2010Date Analyzed:

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose Fiber Wollastonite

NoGasket, Green, Homogeneous None Detected70-01 5% 4%

Other Non-Fibrous Material 91%

Cellulose Fiber Wollastonite

NoGasket, Green, Homogeneous None Detected70-02 5% 4%

Other Non-Fibrous Material 91%

Cellulose Fiber Wollastonite

NoGasket, Green, Homogeneous None Detected70-03 5% 4%

Other Non-Fibrous Material 91%

Cellulose Fiber Wollastonite

NoLAYER 1 Mastic, White, Homogeneous

None Detected70-04 3% 2%

Other Non-Fibrous Material 95%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 1 of 33

Lab DirectorLee W. Poye

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose Fiber Wollastonite

NoLAYER 1 Mastic, White, Homogeneous

None Detected70-05 3% 2%

Other Non-Fibrous Material 95%

NoLAYER 2 Mastic, Tan, Homogeneous

None Detected Other Non-Fibrous Material 100%

Fibrous GlassNoLAYER 3 Insulation, Yellow, Homogeneous

None Detected 100%

Cellulose Fiber Wollastonite

NoLAYER 1 Mastic, White, Homogeneous

None Detected70-06 3% 2%

Other Non-Fibrous Material 95%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Cellulose Fiber Fibrous Glass

NoInsulation, Gray/ Beige, Homogeneous

None Detected70-07 5% 5%

Other Non-Fibrous Material 90%

Cellulose Fiber Fibrous Glass

NoInsulation, Gray/ Beige, Homogeneous

None Detected70-08 5% 5%

Other Non-Fibrous Material 90%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 2 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose Fiber Fibrous Glass

NoInsulation, Beige, Homogeneous None Detected70-09 5% 5%

Other Non-Fibrous Material 90%

Cellulose FiberNoLAYER 1 Wrap, Brown/ Beige, Homogeneous

None Detected70-10 75%

Other Non-Fibrous Material 25%

Cellulose Fiber Fibrous Glass

NoLAYER 2 Mastic Wrap, Purple/ White, Homogeneous

None Detected 25% 10%

Other Non-Fibrous Material 65%

Cellulose Fiber Fibrous Glass

NoLAYER 3 Insulation, Gray, Homogeneous

None Detected 5% 5%

Other Non-Fibrous Material 90%

Cellulose FiberNoLAYER 1 Wrap, Brown/ Beige, Homogeneous

None Detected70-11 75%

Other Non-Fibrous Material 25%

Cellulose Fiber Fibrous Glass

NoLAYER 2 Mastic Wrap, Purple/ White, Homogeneous

None Detected 25% 10%

Other Non-Fibrous Material 65%

Cellulose Fiber Fibrous Glass

NoLAYER 3 Insulation, Gray, Homogeneous

None Detected 5% 5%

Other Non-Fibrous Material 90%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 3 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose FiberNoLAYER 1 Wrap, Brown/ Beige, Homogeneous

None Detected70-12 75%

Other Non-Fibrous Material 25%

Cellulose Fiber Fibrous Glass

NoLAYER 2 Mastic Wrap, Purple/ White, Homogeneous

None Detected 25% 10%

Other Non-Fibrous Material 65%

Cellulose Fiber Fibrous Glass

NoLAYER 3 Insulation, Gray, Homogeneous

None Detected 5% 5%

Other Non-Fibrous Material 90%

Cellulose FiberNoLAYER 1 Wrap, Brown/ White, Homogeneous

None Detected70-13 75%

Other Non-Fibrous Material 25%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Cellulose FiberNoLAYER 1 Wrap, Brown/ White, Homogeneous

None Detected70-14 75%

Other Non-Fibrous Material 25%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 4 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose FiberNoLAYER 1 Wrap, Brown/ White, Homogeneous

None Detected70-15 75%

Other Non-Fibrous Material 25%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Cellulose Fiber Fibrous Glass

NoLAYER 1 Wrap, Tan/ White, Homogeneous

None Detected70-16 2% 5%

Other Non-Fibrous Material 93%

Cellulose Fiber Synthetic Fiber

NoLAYER 2 Insulation, Gray, Homogeneous

None Detected 5% 15%

Other Non-Fibrous Material 80%

Cellulose Fiber Fibrous Glass

NoLAYER 1 Wrap, Tan/ White, Homogeneous

None Detected70-17 2% 5%

Other Non-Fibrous Material 93%

Cellulose Fiber Synthetic Fiber

NoLAYER 2 Insulation, Gray, Homogeneous

None Detected 5% 15%

Other Non-Fibrous Material 80%

Synthetic FiberNoLAYER 3 Insulation, Beige, Homogeneous

None Detected 15%

Other Non-Fibrous Material 85%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 5 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose Fiber Fibrous Glass

NoLAYER 1 Wrap, Tan/ White, Homogeneous

None Detected70-18 2% 5%

Other Non-Fibrous Material 93%

Cellulose Fiber Synthetic Fiber

NoLAYER 2 Insulation, Gray, Homogeneous

None Detected 5% 15%

Other Non-Fibrous Material 80%

Synthetic FiberNoLAYER 3 Insulation, Beige, Homogeneous

None Detected 15%

Other Non-Fibrous Material 85%

Cellulose Fiber Synthetic Fiber

NoInsulation, White/ Beige, Homogeneous

None Detected70-19 5% 15%

Other Non-Fibrous Material 80%

Cellulose FiberNoLAYER 1 Mastic Wrap, White, Homogeneous

None Detected70-20 5%

Other Non-Fibrous Material 95%

Cellulose Fiber Synthetic Fiber

NoLAYER 2 Insulation, Beige, Homogeneous

None Detected 5% 15%

Other Non-Fibrous Material 80%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 6 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose FiberNoLAYER 1 Mastic Wrap, White, Homogeneous

None Detected70-21 5%

Other Non-Fibrous Material 95%

Cellulose Fiber Synthetic Fiber

NoLAYER 2 Insulation, Beige, Homogeneous

None Detected 5% 15%

Other Non-Fibrous Material 80%

Cellulose FiberNoGasket, Red, Homogeneous None Detected70-22 5%

Other Non-Fibrous Material 95%

Cellulose FiberNoGasket, Red, Homogeneous None Detected70-23 5%

Other Non-Fibrous Material 95%

Cellulose FiberNoGasket, Red, Homogeneous None Detected70-24 5%

Other Non-Fibrous Material 95%

Cellulose Fiber Fibrous Glass

NoLAYER 1 Mastic Wrap, Brown/ White, Homogeneous

None Detected70-25 10% 10%

Other Non-Fibrous Material 80%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 7 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose Fiber Fibrous Glass

NoLAYER 1 Mastic Wrap, Brown/ White, Homogeneous

None Detected70-26 10% 10%

Other Non-Fibrous Material 80%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Cellulose Fiber Fibrous Glass

NoLAYER 1 Mastic Wrap, Brown/ White, Homogeneous

None Detected70-27 10% 10%

Other Non-Fibrous Material 80%

Fibrous GlassNoLAYER 2 Insulation, Yellow, Homogeneous

None Detected 100%

Fibrous GlassNoGasket, White, Homogeneous None Detected70-28 100%

Fibrous GlassNoGasket, White, Homogeneous None Detected70-29 100%

Fibrous GlassNoGasket, White, Homogeneous None Detected70-30 100%

NoSink Soundproof, Gray/ Brown, Homogeneous

None Detected70-31 Other Non-Fibrous Material 100%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 8 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

Cellulose Fiber Fibrous Glass

NoCeiling Tile, White/ Gray, Homogeneous

None Detected70-32 45% 10%

Other Non-Fibrous Material 45%

Cellulose Fiber Fibrous Glass

NoCeiling Tile, White/ Gray, Homogeneous

None Detected70-33 45% 10%

Other Non-Fibrous Material 45%

Cellulose Fiber Fibrous Glass

NoCeiling Tile, White/ Gray, Homogeneous

None Detected70-34 45% 10%

Other Non-Fibrous Material 45%

Cellulose Fiber Fibrous Glass

NoCeiling Tile, White/ Gray, Homogeneous

None Detected70-35 45% 10%

Other Non-Fibrous Material 45%

Cellulose Fiber Fibrous Glass

NoCeiling Tile, White/ Gray, Homogeneous

None Detected70-36 45% 10%

Other Non-Fibrous Material 45%

Cellulose Fiber Fibrous Glass

NoCeiling Tile, White/ Gray, Homogeneous

None Detected70-37 45% 10%

Other Non-Fibrous Material 45%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 9 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

NoLAYER 1 Floor Tile, White, Homogeneous

None Detected70-38 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Mastic, Black/ Yellow, Homogeneous

None Detected 3%

Other Non-Fibrous Material 97%

NoLAYER 1 Floor Tile, White, Homogeneous

None Detected70-39 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Mastic, Black/ Yellow, Homogeneous

None Detected 3%

Other Non-Fibrous Material 97%

NoLAYER 1 Floor Tile, White, Homogeneous

None Detected70-40 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Mastic, Black/ Yellow, Homogeneous

None Detected 3%

Other Non-Fibrous Material 97%

NoLAYER 1 Floor Tile, White, Homogeneous

None Detected70-41 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Mastic, Black, Homogeneous

None Detected 3%

Other Non-Fibrous Material 97%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 10 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

NoLAYER 1 Floor Tile, White, Homogeneous

None Detected70-42 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Mastic, Black, Homogeneous

None Detected 3%

Other Non-Fibrous Material 97%

NoLAYER 1 Floor Tile, White, Homogeneous

None Detected70-43 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Mastic, Black, Homogeneous

None Detected 3%

Other Non-Fibrous Material 97%

NoMastic, Gray, Homogeneous None Detected70-44 Other Non-Fibrous Material 100%

NoMastic, Gray, Homogeneous None Detected70-45 Other Non-Fibrous Material 100%

NoMastic, Gray, Homogeneous None Detected70-46 Other Non-Fibrous Material 100%

NoMastic, Yellow, Homogeneous None Detected70-47 Other Non-Fibrous Material 100%

NoMastic, Yellow, Homogeneous None Detected70-48 Other Non-Fibrous Material 100%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 11 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

NoMastic, Yellow, Homogeneous None Detected70-49 Other Non-Fibrous Material 100%

NoMastic, Yellow, Homogeneous None Detected70-50 Other Non-Fibrous Material 100%

NoLAYER 1 Texture, White, Homogeneous

None Detected70-51 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Tape, White, Homogeneous

None Detected 100%

NoLAYER 3 Joint Compound, White, Homogeneous

None Detected Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 4 Wallboard, Brown/ White, Homogeneous

None Detected 10% <1%

Other Non-Fibrous Material 90%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 12 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

NoLAYER 1 Texture, White, Homogeneous

None Detected70-52 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Tape, White, Homogeneous

None Detected 100%

NoLAYER 3 Joint Compound, White, Homogeneous

None Detected Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 4 Wallboard, Brown/ White, Homogeneous

None Detected 10% <1%

Other Non-Fibrous Material 90%

NoLAYER 1 Texture, White, Homogeneous

None Detected70-53 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Tape, White, Homogeneous

None Detected 100%

NoLAYER 3 Joint Compound, White, Homogeneous

None Detected Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 4 Wallboard, Brown/ White, Homogeneous

None Detected 10% <1%

Other Non-Fibrous Material 90%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 13 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

NoLAYER 1 Texture, White, Homogeneous

None Detected70-54 Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 2 Wallboard, Brown/ White, Homogeneous

None Detected 10% <1%

Other Non-Fibrous Material 90%

NoLAYER 1 Texture, White, Homogeneous

None Detected70-55 Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 2 Wallboard, Brown/ White, Homogeneous

None Detected 10% <1%

Other Non-Fibrous Material 90%

NoLAYER 1 Painted Texture, Pink/ White, Homogeneous

None Detected70-56 Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 2 Wallboard, Brown/ White, Homogeneous

None Detected 10% <1%

Other Non-Fibrous Material 90%

Eric Montoya Analyst

This report relates only to the materials tested. This report is for the exclusive use of the addressed client and shall not be reproduced except in full, without written approval by J3 Resources, Inc. (J3). Samples are analyzed according to EPA test methods listed above and are subject to the inherent limitations of Polarized Light Microscopy and interference of matrix components. J3 recommends TEM confirmation of non-friable organically bound materials reported as < 1% by PLM. All samples received in good condition unless otherwise noted. This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

NVLAP Lab Code: 200525-0; AIHA Lab ID: 157714; TDSHS License: 30-0273 Page 14 of 33

JH1033000J3 Order #:

VAMC - BLDG 70

1052 Hercules Drive Houston TX 77058

Micro Air of Texas Melissa Kiser

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM)

EPA 600/M4-82-020; 600/R-93/116

Asbestos (Yes/No)

Sample Description Asbestos Constituents

Sample ID # Location Non-Asbestos Constituents

J3 Resources, Inc.

6110 W. 34th Street, Houston, Texas 77092

Phone: (713) 290-0221 - Fax: (713) 290-0248

J3Resources.com

02-Apr-2010Date Reported:

NoLAYER 1 Painted Texture, White, Homogeneous

None Detected70-57 Other Non-Fibrous Material 100%

Cellulose FiberNoLAYER 2 Tape, White, Homogeneous

None Detected 100%

NoLAYER 3 Joint Compound, White, Homogeneous

None Detected Other Non-Fibrous Material 100%

Cellulose Fiber Fibrous Glass

NoLAYER 4 Wallboard,…