This document is a technical specification sheet for the TLS4 Automatic Tank Gauge, a compact console designed for small retail, commercial, and industrial tank monitoring applications. The device offers 12 universal sensor inputs, multiple console configurations (with or without color touch screen display), and optional software features including Business Inventory Reconciliation, Continuous Statistical Leak Detection, and Vapor Collection Monitoring. Key technical specifications include a 7" color WVGA LCD touch screen, operating temperature range of +32 to +122°F, universal AC or DC power supply options, and robust system security features like partitioned Ethernet ports and user-specific access controls.

The console provides comprehensive tank monitoring capabilities, including inventory control, tank calibration, leak detection (0.1 and 0.2 GPH), interstitial/sump leak sensing, vapor well monitoring, and multiple customizable alarm features. It is certified for various approvals including UL, cUL, ATEX, IECEx, and NEPSI, and supports multiple installation and monitoring functions such as hydrocarbon vapor detection, groundwater monitoring, and programmable alarm limits. The device is designed for flexibility, with modular/expandable features and optional add-ons to suit different monitoring requirements across various industrial environments.

View the file

Other files for this federal contract opportunity

Other files attached to J091--Tank Testing and Veeder Root Installation Brand Name or Equal, newest first.
File Type Posted
S06 36C25725B0016 0003.pdf PDF
Attachment 3 TLS4 and TLS4B Brocure.pdf PDF
Attachment 2 UST locations.pdf PDF
36C25725B0016 0002.docx DOCX document
Attachment 1 Waco UST Tank Information.pdf PDF
36C25725B0016 0001.docx DOCX document
Site Visit Sign in Sheet.pdf PDF
Attachment 5 TLS4i_Automatic_Tank_Gauge.pdf PDF
Attachment 3 Wage Determination.pdf PDF
Attachment 1 Statement of Work.doc DOC document
36C25725B0016_1.docx DOCX document
Attachment 4 Feb 2025 Deviations.docx DOCX document
Attachment 2 PCRA.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TLS4 Automatic Tank Gauge

Console Description

The TLS4 Automatic Tank Gauge is a compact, powerful, and expandable console. Its combination of precision performance, customization, and ease-of-use to deliver proven results make it ideal for small retail, commercial and industrial applications. The TLS4 has 12 universal sensor or probe inputs (when using only two-wire devices).

TLS4 Consoles, Standard Hardware & Software

Console Part # & Description Standard Hardware & Application Software

1. 0860190-x20 TLS4 Console, Color Touch Screen Display, EDIM or CDIM, UL

2. 0860190-x10 TLS4 Console, No Display, EDIM or

CDIM, UL

3. 0860160-x20 TLS4 Console, Color Touch Screen Display, EDIM, CDIM or IFSF, ATEX

4. 0860160-x10 TLS4 Console, No Display, EDIM, CDIM or IFSF, ATEX

Software – 0333434-001 Application Software (must be ordered with Console) includes Web-enabled, Custom Alarm, On-Console Help, Extended Storage, and Static In-Tank Leak Detection (SLD), for USTs only Hardware – Included with Console: Two Configurable RS-232/485 Serial Ports (Isolated), Three (Two Switched Network) Ethernet Ports, Two External USB 2.0 Ports, Two Relay Outputs (120/240VAC 5A; 30VDC 5A; Fuse Ratings 5A, 250VAC Type T (Slo-Blo)), One Low Voltage Input (max.

contact closure ratings 12VDC 0.015A Class I wiring is required for 12 volt closure circuits)

TLS4 Optional Software

Part # & Description

Continuous Statistical Leak Detection (CSLD), for USTs only 0333410-006

Business Inventory Reconciliation (BIR)/Hourly Reconciliation Mode (HRM)/Accuchart 0333410-012

Timed Sudden Loss Detection 0333410-018

Vapor Collection Monitor 0333410-021

Note: If software features are added to an existing console, the Feature Enhancement will be shipped with a kit that includes a wrist strap, manual, iButton holder and programmed iButton – 0333530-002.

Optional Printer for TLS4 Series Consoles

Part # & Description

External Printer for TLS4 Series Consoles (Epson Model: TM-T88V) 0330020-832

Wall Mounting Bracket for External Printer for TLS4 Series Consoles 0330020-839

Specifications

Operating Temperature +32 to +122°F (0 to +50°C)

Storage Temperature -40 to +158°F (-40 to +70°C)

Installation Location NEMA 4 or indoors; must maintain Operating Temperature requirement stated above.

Relative Humidity 0-90% (non-condensing)

External Dimensions 13" x 8" x 3.5" (33.02cm x 20.32cm x 8.89cm)

Construction 16GA (0.060"/0.1524cm) powder coated steel

Console Power Wiring Requirements

AC Power Wiring – Wires carrying 120 or 240VAC from power panel to the console should be #14 AWG (or larger) wire for line, neutral & chassis ground (3); and 4 sq. mm, rated for at least 90C for barrier ground.

Probe & Sensor to Console Wiring Requirements

1. Wire Type – Shielded cable required regardless of conduit materiel or application. Shielded cable must be rated less than 100 picofarad per ft manufactured with a suitable material such as Carol C2534 or Belden 88760, 8760, or 8770. Cable must be oil and gas resistant.

2. Wire Length – maximum 1,000ft (304.8m) to meet intrinsic safety requirements. Improper system operation could result for runs over 1,000ft (304.8m).

3. Wire Gauges – Color coded – shielded cable used in all installations. Wires should be #14 - #18 AWG stranded copper wire and installed as Class 2 circuits. As an alternate method when approved by the local authority having jurisdiction, #22 AWG wire such as 88761 may be suitable with the following requirements: wire run is less than 750ft (228.6m), Capacitance does not exceed 100 pF/foot, Inductance does not exceed 0.2 uH/ft.

Specifications (continued)

System Power Requirements

Either AC input or DC input, but not both.

1. Universal AC power supply: 100 to 249VAC, 50/60Hz, 2A max.

2. DC power supply: +24VDC, 2A max. and +5VDC, 4A max. Um <= 250Vrms or 250VDC.

Display Specifications 7" (17.78cm) Color WVGA LCD touch screen display

Data Storage Features SD card

Custom User Access Front Panel Display control through user specific log-in;

User defined roles to restrict access/functionality.

Screen permissions can be limited to view, edit, perform.

System Security

1. Partitioned Ethernet Ports that can be used to separate user network from the internet

2. Port availability control: SSH Port (22), HTTPS Port (443), Serial Command Port (10001)

3. Reassign Port Numbers (i.e., HTTPS on 50443)

4. System Integrator CVE Scans & Fixes

5. Periodic System Updates to protect against persistent threats

Customized Alarm Features Customizable for all alarms

Approvals UL cUL, ATEX, IECEx, NEPSI, FCC, FMC, PESO

Third Party Evaluations https://neiwpcc.org/nwglde/

Product Installation Guide https://www.veeder.com/us/technical-document-library

TLS4 Automatic Tank Gauge

System Compatibilities Guide

Feature/Console TLS4

CONSOLE DESIGN

Modular/Expandable Features • LCD with Touch Screen 7" WVGA Color Integral Roll Printer N/A Universal Power Supply •

INVENTORY CONTROL

Graphical Inventory Status • Complete Inventory Reports • Programmable Auto Report Times • Inventory Increase Report • Timed Sudden Loss Detection Optional

BUSINESS INVENTORY RECONCILIATION (BIR)

Shift-Based Reconciliation Optional Reconciliation by Tank Optional

TANK CALIBRATION

AccuChart™ Optional Multi-Pass Tank Calibration Optional Single-Pass / Metered Drop Optional Limited Range Calibration Optional Supports Multiple Tank Charts per Tank Optional Supports Multiple Line Manifold Tanks Optional * Graphical / Text Calibration Diagnostics Optional Automatic and Manual Meter Mapping Optional

IN-TANK LEAK TEST

0.1 GPH Tank Tightness Testing •

0.2 GPH Tank Tightness Testing •

Continuous Statistical Leak Detection Optional Selectable Test Rates • Programmable Automatic Test Schedules • PASS, FAIL, or INVALID Indicators •

LINE LEAK DETECTION

Integral Line Leak Detector N/A Programmable Line Test Features N/A

INTERSTITIAL/SUMP LEAK SENSING

Tank Annulus • Sump • Dispenser Pan • Mag Sump • Sensor Location Identifiers •

VAPOR WELL MONITORING

Hydrocarbon Vapor Detection • High Water Level Alarm •

GROUNDWATER MONITORING

Hydrocarbon Liquid Detection • Low Water Alarm •

AIR VAPOR MONITORING

Vapor Collection Monitor Optional

ALARMS

Leak • Overfill • High Level • Sudden Loss • High Water • Low Inventory • Programmable Alarm Limits • veeder.com +1.800.873.3313

125 Powder Forest Drive • PO Box 2003 • Simsbury, CT 06070 • ©2025 Veeder-Root • P/N 577014-479 Rev. B All information contained in this document is subject to change without notice.

* with a TLS-XB Expansion Box https://neiwpcc.org/nwglde/ https://www.veeder.com/us/technical-document-library

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.

This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root.

Example Illustrations

Illustrations used in this guide for example sensor installations may contain components that are customer supplied and not included with the sensor. Please check with your Veeder-Root Distributor for recommended installation accessories.

Third Party Evaluations

Third party evaluations of the Veeder-Root sensors contained in this application guide can be found under the Veeder-Root vendor name on the National Work Group on Leak Detection Evaluations (NWGLDE) website:

https://neiwpcc.org/nwglde/

©2025 Veeder-Root. All rights reserved.

https://neiwpcc.org/nwglde/

File details come from the government source that posted it. Updated .