This document contains a Request for Quote (RFQ) for repair and retrofitting solar street and parking lot lighting. The Department of Veterans Affairs, Network Contracting Office 17 is soliciting offers for services to be performed at Central Texas Veterans Health Care Facility in Temple, Texas in accordance with the Performance Work Statement. The opportunity is set aside for Service-Disabled Veteran Owned Small Business (SDVOSB)/Veteran Owned Business. Interested SDVOSBs must be registered in SAM and listed to receive awards. A site visit will take place on June 28th at 9:00 AM. Offerors must submit technical questions in writing by July 1st and offers directly via email by July 15th at 1:00 PM to the Contract Specialist. The government anticipates awarding a firm-fixed price contract resulting from this solicitation.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F E A T U R E S & B E N E F I T S

Valve-Regulated Sealed construction eliminates periodic watering, corrosive acid fumes, and spills

Gelled Electrolyte Electrolyte will not stratify

Positive and Negative Plate Lead calcium

Self-Discharge Less than 2% per month stand loss means little deterioration during transport and storage

Exclusive IPF® Technology Optimizes power capacity, cell consistency, and long-term reliability

Rated Non-Spillable by ICAO, Transports easily and safely by air, IATA, and DOT no special containers needed

A P P L I C A T I O N S

Renewable Energy • Water pumping • Residential • Communications

• Cathodic protection • Remote monitoring • Refrigeration

• Lighting • Aids to navigation • Wind generation

The Deka Solar Valve-

Regulated Gel Monobloc series offers reliable, versatile, maintenance-free power. The thixotropic gel enables these batteries to be completely spillproof providing many available options for installation. The gelled electrolyte gives more protection to the battery plates, and is better suited for deep cycle discharge. With longer discharge and less charging time, these batteries are ideal for many renewable energy applications.

GEL MONOBLOC/

6V & 12V

GEL MONOBLOC/

6V & 12V

P H O T O V O L T A I C B A T T E R I E SP H O T O V O L T A I C B A T T E R I E S

B C G S T U X Y

Capacity vs. Operating Temperatures: Above are the changes in capacity for wider ambient temperature range, giving the available capacity, as a percentage of the rated capacity, at different ambient temperatures. The curves show the behavior of the battery after a number of cycles.

Capacity vs. Operating Temperature

Terminal InformationThe solar battery excels in cycling applications.

*Dependent upon proper charging and ambient temperatures.

Footnotes:

17 - Includes handle 38 - “Non-Spillable” defined by DOT(Department of Transportation) definitions 39 - “Non-Spillable” defined by ICAO (International

Commercial AirlineOrganization) and IATA (International Airline Transport Association) definitions

B - Flag Terminal w/ 3/8" diameter hole

C - 1/4-20 Treaded Insert G - Flag Terminal w/ 5-16" diamater hole S - SAE “automotive type” post (TSAE)

ALL RATINGS ARE AFTER 15 CYCLES AND CONFORM TO B.C.I.

SPECIFICATIONS.

IMPORTANT CHARGING INSTRUCTIONS: WARRANTY VOID IF OPENED

OR IMPROPERLY CHARGED. Do not install in a sealed container. Constant under or overcharging will damage any battery and shorten its life! Use a good constant potential, voltage-regulated charger. The open circuit voltage of a fully charged 12-volt battery is 12.8V at 77°F (25°C).

Batteries manufactured in polypropylene cases and covers.

Batteries manufactured with gray case / gray cover unless noted.

**Peak Rating - Maximum amount of amp-hours a battery can deliver at a specified rate

Cycle Life vs Depth of Discharge at +25°C (77°F)*

Cut-off parameters per charge & equalize intervals are application specific and will vary dependent upon site specific characteristics such as temperature, days of autonomy, array to load ratio, etc.

8GU1 39,39,Y 12 30.5 31.6 31.9 36.0 28.4 33.3 36.5 1175 23 (10.5) 7.71 (196) 5.18 (132) 7.22 (183) 8GU1H 17,38,39,Y 12 30.5 31.6 31.9 36.0 28.4 33.3 36.5 1175 23 (10.5) 8.31 (211) 5.18 (132) 7.22 (183) 8G40C 38,39,C 12 37.0 40.0 40.8 48.0 36.0 42.1 48.7 1331 32 (14.5) 7.76 (197) 6.62 (168) 6.87 (174) 8G22NF 38,39,G 12 47.5 51.0 51.6 58.0 45.8 53.7 58.9 1335 37 (16.8) 8.99 (228) 5.47 (139) 9.24 (235) 8G34R 38,39,C 12 53.0 60.0 61.7 70.0 50.3 63.2 71.0 1845 42 (19.1) 10.20 (259) 6.65 (169) 7.05 (179) 8G24 17,38,39,G 12 68.0 73.6 74.9 84.5 66.0 77.0 85.0 2012 52 (23.6) 10.20 (259) 6.80 (173) 9.24 (235) 8G27 17,38,39,G 12 80.3 88.0 88.1 99.0 76.0 91.0 100 2348 63 (28.6) 12.83 (326) 6.56 (167) 9.24 (235) 8G30H 17,38,39,B 12 90.0 97.6 98.4 108 85.0 102 108 2715 70 (31.8) 12.93 (329) 6.75 (171) 9.76 (248) 8G31 17,38,39,X 12 90.0 97.6 98.4 108 85.0 102 108 2796 70 (31.8) 12.93 (329) 6.75 (171) 9.34 (237) 8GGC2 38,39,U 6 168 180 182 198 154 189 198 3647 68 (30.8) 10.26 (261) 7.09 (180) 11.06 (281) 8G4D 17,38,39,T 12 169 183 187 210 153 193 213 5482 127.5 (58.0) 20.73 (527) 8.44 (214) 10.82 (275) 8G8D 17,38,39,T 12 210 225 229 265 188 237 269 5794 157 (71.0) 21.03 (534) 11.00 (279) 10.82 (275) 8G5SHP 17,B 12 107 115 116 123 110 125 137 2686 85 (38.5) 13.58 (345) 6.77 (172) 11.42 (290) 8GTE35 S (TSAE) 6 183 196 199 211 180 210 220 2902 69 (31.0) 9.64 (245) 7.51 (191) 10.65 (270) 8G8VGC U 8 126 140 143 160 114 147 162 4117 70 (31.8) 10.26 (216) 7.09 (180) 11.05 (281)

BATTERY TYPE FOOT NOTE VOLTS

AMPERE HOUR CAPACITY 77°F (25°C) PEAK RATING** [1.75 vpc @ 77°F (25°C)] SHORT CIRCUIT WEIGHT DIMENSIONS - in (mm)

T - “L” Terminal w/ 3/8" diameter hole

U - 5/16" Threaded Post / SAE X - 3/8-16 stainless steel threaded post Y - Small “L” terminal w/

5/16" diameter hole

10 HR 20 HR 24 HR 100 HR 5 HR 20 HR 100 HR CURRENT lb (kg) L W H*

Photovoltaic Charging Parameters Bulk Charge Max Current (amps) 30% of 20 Hr Rate Absorption (Regulation) Charge Constant Voltage 2.35 - 2.40 vpc Float Charge Constant Voltage 2.25 vpc ± 0.01 Equalize Charge Constant Voltage 2.40 - 2.43 vpc Temperature Coefficient 0.003 v / °C

Cycle Chart applies to types with similiar design characteristics, ex. 24, 27, 31.

Ambient Temperature (°C)

P er ce n ta g e o f A va ila b le C ap ac it y

-40 -30 -20 -10 0 10 20 30 40 50 60 0%

20%

40%

60%

80%

100%

120%

E.P.M. Form No. 0919 Rev. 05/16 © 2016 by EPM Printed in U.S.A.

All data subject to change without notice.

No part of this document may be copied or reproduced, electronically or mechanically, without written permission from the company.

Domestic Inquiries Call: 1-800-372-9253 www.mkbattery.com • e-mail: sales@mkbattery.com

East Penn Manufacturing Co., Lyon Station, PA 19536-0147 Domestic & International Inquiries Call: 610-682-3263 Phone: 610-682-6361 • Fax: 610-682-0891 www.dekabatteries.com • e-mail: reservepowersales@dekabatteries.com

Depth of Discharge (%)

C yc le s

P H O T O V O L T A I C B A T T E R I E S