Attachment_B_Decon Site Prep.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25624R0052
About this file
This pre-solicitation notice provides information for Project 520-22-169 to upgrade mechanical systems at three Department of Veterans Affairs locations. The project involves upgrading mechanical systems at the Joint Ambulatory Care Clinic in Pensacola, Florida, the Magnolia Clinic in Panama City, Florida, and the Eglin Air Force Base VA Clinic in Eglin AFB, Florida. The scope of work includes upgrades to HVAC, plumbing, and electrical systems. The anticipated solicitation date is listed as TBD. Interested parties are advised to monitor the federal business opportunities website for release of the subsequent solicitation containing proposal due dates and other details. The contracting agency is listed as the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Full Drawing Set Final.pdf | ||
| 36C25624R0052 EXHIBIT B.docx | DOCX document | |
| WD Okaloosa County FL20240217.pdf | ||
| P03 Brand Name JA 520-22-169 (CO Signed) - Copy_Redacted.pdf | ||
| 36C25624R0052 EXHIBIT E.docx | DOCX document | |
| Attachment_A_Basis of Design Submittals rev1.pdf | ||
| 36C25624R0052 EXHIBIT F.docx | DOCX document | |
| 36C25624R0052 EXHIBIT A.docx | DOCX document | |
| 36C25624R0052 Solicitation.pdf | ||
| 36C25624R0052 EXHIBIT D.docx | DOCX document | |
| WD Bay County FL20240005.pdf | ||
| ICRA JACC Mechanical Upgrade Contract ONLY.pdf | ||
| P09 (REVISED) 520-22-169 SOW Upgrade Mech Systems JACC Eglin PCY rev4.docx | DOCX document | |
| WD Escambia County FL20240203.pdf | ||
| 36C25624R0052 EXHIBIT C.docx | DOCX document | |
| Specs rev6.pdf | ||
| 36C25624R0052 Pre-solicitation.docx | DOCX document | |
| P09 (REVISED) 520-22-169 SOW Upgrade Mechanical Systems JACC Eglin PCY rev4.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
New washer location
Attachment B: Decon Site Prep
New washer location
Remove
Eye-wash
42 [1067]
UNIT WIDTH
80 [2032]
UNIT
HEIGHT
31 [787]
LOADING
HEIGHT
26-1/4 [667]
LOADING
CLEARANCE
HEIGHT
[203]
[305]
91 [2311]
RAISED DOOR
HEIGHT
32 [813]
MAX LENGTH
31 [787]
UNIT LENGTH
94 [2388]
SERVICE AREA
HEIGHT
11 [279]
45 [1143]
WALL OPENING
*(NOTE F)
1-1/2 [38]
MINIMUM
94 (2388)
*(NOTE E, F AND G)
MAX 1 [25]
ADJUSTMENT WITH
WASHER LEGS
(UNIT HEIGHT 81 MAX)
MINIMUM
90 [2286]
*(NOTE E, F AND G)
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SERVICE AREA
REQUIRED FOR
DRYING MOTOR
REMOVAL
TYPICAL INSTALLATION
NOTES:
(A) UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN INCHES [MM].
(B) SERVICE ACCESS SIDE OF UNIT IS RECOGNIZED BY THE TOUCH SCREEN AT THE RIGHT OF
WASH CHAMBER. ELECTRICAL AND CONTROL COMPONENTS, AS WELL AS MOST OF
SERVICABLE PARTS ARE ACCESSIBLE FROM THAT SIDE OF UNIT. NON-SERVICE SIDE IS
EQUIPPED WITH THE TOUCH SCREEN ON THE LEFT OF THE WASH CHAMBER.
(C) CUSTOMER MUST BE SURE THAT MACHINE STANDS ON A NON-COMBUSTIBLE FLOOR.
(D) WEIGHTED EQUIVALENT SURFACE SOUND PRESSURE LEVEL: 64.0 db(A) CALCULATED AS DESCRIBED IN ISO 3746.
(E) VERTICAL BARRIER WALL FLANGES ARE PROVIDED WITH UNIT TO FILL GAP BETWEEN
UNIT AND WALL ON BOTH SIDES. DIMENSIONS ARE 3-1/2 [88.9] WIDTH X 82 [2082.8] LONG.
(F) HORIZONTAL BARRIER WALL FLANGES ARE PROVIDED WITH UNIT TO FILL GAP BETWEEN
UNIT AND WALL ON BOTH SIDES. DIMENSIONS ARE 49 [1244.6] WIDTH X 16-3/8 [416] HEIGHT.
(G) FOR A WASHER INSTALLATION WITH BARRIER WALL FLANGES,THE WALL OPENING HEIGHT
MUST BE BETWEEN, 90 AND 95.5 [2286-2426] AND MINIMUM CEILING HEIGHT MUST BE 98 [2489].
FRONT VIEW
SERVICE ACCESS
SIDE OF UNIT
*(NOTE B)
TOP VIEW
PASS THROUGH
DOOR
SIDE VIEWLEVEL FLOOR
*(NOTE C)
W A
LL
O
P E
N
IN
G H
E
IG
H T
C E
IL
IN
G H
E
IG
H T
F O
R D
O O
R R
E M
O V
A L
[102]
Page 1 of 10 10232353.F
Released
2X 36-1/4 [921]
2X 26-1/2 [673]
4-3/8 [111]
1-3/4 [44]
27-1/4 [692]
[533]
6-1/4 [159]
11-1/4 [286]
6X 12 [305]
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
*NOTES:
(A) CONCRETE FLOOR MUST REMAIN FREE OR DEFECTS IN THESE AREA, AS PER ESR-1917 SECTION 4.1.10
FOR INSTALLATION OF SEISMIC ANCHORS (NOT PROVIDED BY STERIS).
(B) THE FLOOR SINK AND DRAIN SHALL NOT OCCUPY THESE AREAS.
SEISMIC MOUNTS
SEISMIC ANCHORAGE
FOR DETAIL SEE FD085
QTY 4 OR 6 ANCHORS
FINISHED WALL
PREFERENCE
LOCATION OF
FLOOR SINK.
SEE PAGE 4 *(NOTE 5)
*(NOTE A AND B)
Page 2 of 10 10232353.F
[2032]
6-1/4 [159]
31-1/2 [800]
31-1/8 [791]
13-7/8 [352]
16-1/2 [419]
[483]
21-1/2 [546]
11-1/4 [286]
HW HOT WATER
CW COLD WATER
PW PURE WATER
A COMPRESSED AIR
D FLOOR DRAIN LOCATION
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
UTILITY (PLUMBING)
CONNECTION POSITION
FRONT VIEW
A
PW
HW
CW
D
SIDE VIEW
HW
CW
PW
A
D
TOP VIEW
HW
CW
PW
A
D
Page 3 of 10 10232353.F
74-3/4 [1898.7]
35-3/8 [898.5]
[508]
[762]
[228.6]
34-1/8 [866.8]
E ELECTRICAL
N NETWORK
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
UTILITY (ELECTRICITY)
CONNECTION POSITION
FRONT VIEW SIDE VIEW
EN E
N
TOP VIEW
E
N
Page 4 of 10 10232353.F
[2032]
4-3/4 [121]2-3/4
[70]
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
UTILITY (VENTILATION)
CONNECTION POSITION
FRONT VIEW SIDE VIEW
TOP VIEW
Page 5 of 10 10232353.F
60 [1524]
REF
8-3/8 [213]
11FT [3.35m]
MAX.
17 [432]
INSTRUMENT UTENSIL
CHEMICAL
(CH)
ENZYME CONSUPTION PER CYCLE
(SEE PAGE 3; *(NOTE 4))
0.94oz (28ml) at 1/10oz/gal (0.8ml/L) 0.58oz (17.2ml) at 1/10oz/gal (0.8ml/L)
DETERGENT CONSUPTION PER CYCLE
(SEE PAGE 3; *(NOTE 4))
0.94oz (28ml) at 1/10oz/gal (0.8ml/L) 0.58oz (17.2ml) at 1/10oz/gal (0.8ml/L)
LUBRICANT CONSUPTION PER CYCLE
(SEE PAGE 3; *(NOTE 4))
0.23oz (7ml) at 1/10oz/gal (0.8ml/L) N/A
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
*NOTES:
(A) DOSING STATION AND CHEMICAL CONTAINERS MUST BE ON THE SAME FLOOR OF THE BUILDIN AS THE WASHER/DISINFECTOR.
CHEMICAL CONTAINER MUST BE LOCATED AT A LOWER HEIGHT THAN DOSING STATION. MAXIMUM CONTAINER INCLINATION
IS 15 DEG FROM FLOOR. AMBIENT TEMPERATURE SHALL NOT EXCEED 32°C (90°F)
(B) HP PICKUP TUBE SYSTEM CAN PROVIDE UP TO TWO WASHERS WITH CHEMISTRY FROM THE SAME CONTAINER.
DOSING STATION
CEILING
ROUTE CHEMICAL LINES
AND SIGNAL CABLE
THROUGH PIPE TO REACH
BOTTOM OF UNIT
CHEMICAL CONTAINERS
*(NOTE A)
12 FT (3.6M) OF INJECTION LINE
(FROM CONTAINERS TO
DOSING STATION)
*(NOTE B)
DOSING STATION
WEIGHT : 15LBS (6.8KG)
2X FD087 SHOWN
UP TO 5 TUBES
100 FT (30m) OF INJECTION LINE
AND SIGNAL CABLE
DETERGENT LINES SHALL NOT BE IN CONTACT WITH HOT SURFACES.
STERIS RECOMMENDS CUSTOMER TO ROUTE CHEMICAL LINES AND
SIGNAL CABLE THROUGH A 3" (76) ID CONDUIT.
EXCESS LENGTH MUST BE CUT BEFORE CONNECTING TO
WASHER/STATION TO AVOID FORMING BUNDLES THAT COULD
AFFECT THE CHEMICAL INJECTION SYSTEM'S PERFORMANCE
(DO NOT CUT COMMUNICATION CABLES).
Page 6 of 10 10232353.F
AMSCO 5052 SINGLE CHAMBER WASHER/DISINFECTOR
UTILITY REQUIREMENTS CHART (PLUMBING)
UTILITY PARAMETER REQUIREMENT NOTES
HOT WATER
(HW)
*(NOTE 6)
CONNECTION SIZE / TYPE 1/2 in / FEMALE NPT [1/2 in / MALE BSPT]
1. STERIS REQUIRES TO INSTALL WATER HAMMER
ARRESTOR, UNION & PRESSURE GAUGE.
2. CUSTOMER MUST PROVIDE UTILITY
CONNECTIONS WITH SHUTOFFS DISCONNECTS
WITHIN 2 FEET OF THE PERIMETER OF THE
EQUIPMENT AND BELOW THE CEILING DECK.
*STERIS OFFERS FLEXIBLE HOSES
ACCESSORY (FD088 OR FD037)
WITH INSTRUCTIONS.
3. BACK FLOW PREVENTER AGAINST BACK
SIPHONAGE MAY BE REQUIRED (LOCAL
PLUMBING CODE). FOR COLD WATER ONLY.
PRESSURE RANGE
15 - 50 psig DYNAMIC
[103-345 kPa] MAX. 90 psig STATIC [620 kPA]
OPERATING FLOW RATE 12.8 US GPM [48.5 L/min] TO
23.8 US GPM [90.1 L/min]
TOTAL CONSUMPTION PER
INSTRUMENT CYCLE
*(NOTE 4)
28.5 US GAL [108.0L]
TEMPERATURE RANGE 110°F [43°C] TO 150°F [65.5°C]
WATER QUALITY *(NOTE 5) HARDNESS (CaCO3) : 50-80 ppm (MAX. 120 ppm)
COLD WATER
(CW)
*(NOTE 6)
(NOTE 3)
CONNECTION SIZE / TYPE 1/2 in / FEMALE NPT [1/2 in / MALE BSPT]
4. CONSUMPTION BASED ON INSTRUMENT CYCLE WITH
PROLYSTICA ULTRA CONCENTRATE CHEMICALS (PUC)
WITH THE FOLLOWING UTILITY CONDITIONS:
(CW) COLD WATER PRESSURE: 30 psig DYNAMIC [207 kPa]
(CW) COLD WATER TEMPERATURE: 60°F [16°C]
(HW) HOT WATER TEMPERATURE: 110°F [43°C]
(PW) PURE WATER TEMPERATURE 70°F [21°C]
(S) STEAM SUPPLY: 50 psig DYNAMIC [345 kPa]
UTENSIL CYCLE CONSUMPTION:
CW: 17.4 US GAL [66.0L]
HW: 5.8 US GAL [22.2L]
PW: 5.8 US GAL [22.0L]
S: 16.7 LB [7.5KG]
5. STERIS RECOMMENDS THE FOLLOWING WATER
QUALITY PARAMETERS:
TOTAL DISSOLVED SOLIDS: 100-200 ppm (MAX. 500 ppm) TOTAL ALKALINITY (CaCO3) : 70-120 ppm (MAX. 180 ppm) pH : 6.8-7 (MAX. 7.5 ppm) TOTAL SILICA : 0.1-0.5 ppm (MAX. 1 ppm)
6. SAMPLING VALVES INSTALLATION AS CLOSE AS
POSSIBLE TO WASHER WATER CONNECTIONS IS
RECOMMENDED. STERIS OFFERS SAMPLING VALVE
OPTION (FD089)
PRESSURE RANGE
30 - 50 psig DYNAMIC
[206-345 kPa] MAX. 90 psig STATIC [620 kPA]
OPERATING FLOW RATE 18.4 US GPM [69.7 L/min] TO
23.8 US GPM [90.1 L/min]
TOTAL CONSUMPTION PER
INSTRUMENT CYCLE
*(NOTE 4)
FOR SUMP FILLING
9.5 US GAL [108.0L]
ADD. FOR DRAIN COOLDOWN (OPTION)
13.2 US GAL [50.0L]
ADD. FOR NON-VENTED SYSTEM:
16.9 US GAL [64.0 L]
TEMPERATURE RANGE 70°F [21°C] MAXIMUM
WATER QUALITY *(NOTE 5) HARDNESS (CaCO3) : 50-80 ppm (MAX. 120 ppm)
PURE WATER
(PW)
*(NOTE 6)
CONNECTION SIZE / TYPE 1/2 in / FEMALE NPT [1/2 in / MALE BSPT]
7. PW IS OPTIONAL. IF UNAVAILABLE, UNIT WILL
PROCESS THERMAL RINSE USING HOT WATER
SUPPLY.
PRESSURE RANGE
5 - 30 psig DYNAMIC
[30 - 206 kPa] MAX. 90 psig STATIC [620 kPA]
OPERATING FLOW RATE 5.0 US GPM [18.2 L/min] TO
23.7 US GPM [90 L/min]
TOTAL CONSUMPTION PER
INSTRUMENT CYCLE
*(NOTE 4)
9.5 US GAL [36.0 L]
TEMPERATURE RANGE 70°F [21.1°C] TO 150°F [65.5°C]
RESISTIVITY
(CONDUCTIVITY) 0.5-0.1 M -cm [2-10 µS/cm] pH 6.8 - 7.5
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
Page 7 of 10 10232353.F
UTILITY REQUIREMENTS CHART (PLUMBING)
UTILITY PARAMETER REQUIREMENT NOTES
COMPRESSED
AIR
(A)
CONNECTION SIZE / TYPE 1/8 in / FEMALE NPT [1/8 in / MALE BSPT]
1. AIR SPECIFICATIONS (AS PER ISO-8573-1
CLASS 5):
MAX. PARTICLES SIZE 40 microns MAX. PARTICULATE DENSITY 10 mg/m³
MAX. DEW POINT FOR WATER CONTENT
45°F [7°C]
MAX. OIL CONCENTRATION FOR THE OIL
CONTENT 25 mg/m³
2. STERIS RECOMMENDS A REFRIGERATED AIR
DRYER WHERE ENVIRONMENTAL DEW POINT
CONDITIONS ARE HIGHER THAN
RECOMMENDED (CONTACT STERIS SALES
REPRESENTATIVE).
PRESSURE RANGE MIN 80 psig DYNAMIC [552 kPa] MAX. 125 psig STATIC [860 kPA]
OPERATING FLOW RATE 1.75 SCFM [50 L/min]
DRAIN
(D)
CONNECTION SIZE / TYPE 1 1/2 in / MALE NPT
3. STERIS REQUIRES 4 in [102 m] DRAIN.
4. MAX OFFSET OF 3/4 in [19 mm] FROM
OUTLET [PAGE 2, D).
5. STERIS REQUIRES 8 in x 8 in [204 mm x 204 mm] FLOOR SINK
OPERATING FLOW RATE GRAVITY DRAIN : 50 US GPM
[189.3L/min]
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
CHEMICAL
DOSING
SYSTEM
CEILING ROUTING
CONDUIT 3 in CONDUIT
11. STERIS RECOMMENDS TO ROUTE CHEMICAL
LINES AND SIGNAL CABLE THROUGH A
3 in [76 mm] ID CONDUIT (BY OTHERS).
100 ft [ 30m] OF INJECTION LINE AND
SIGNAL CABLE ARE PROVIDED WITH THE UNIT.
Page 8 of 10 10232353.F
30-1/2 [775]
[406]
21-3/4 [552]
[178]
[330]
[686]
[635]
[584]
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
POWER (kVA) 30
INPUT (HV) (V 3~, 60Hz) 208/240/600
OUTPUT (LV) (V 3~, 60Hz) 480
WEIGHT LB (KG) 445 (202)
NOISE LEVEL (dBa) 45
NO LOAD LOSS (WATTS) 188.7
LOAD LOSS
302°F (150°C)
(WATTS) 606.9
TOTAL LOSSES (WATTS) 795.6
EXCITATION
CURRENT
(%) 3.13
INSTALLATION WALL/FLOOR
SIZE IN (MM) SEE RIGHT
PRIMARY CONNECTORS
PER PHASE
(AWG) 1X #2 AWG-#14 AWG
SECONDARY CONNECTORS
PER PHASE
(AWG) 2X #0 AWG-#6 AWG
TEMPERATURE
CLASS
°F (°C) 428° (220°)
WINDING (HV) (LV) COPPER
AMSCO 5052 SINGLE CHAMBER WASHER/DISINFECTOR
UTILITY REQUIREMENTS CHART (ELECTRIC)
UTILITY
PARAMETER AND REQUIREMENT NOTES
CONNECTION
SIZE/TYPE
NOMINAL
AMPERAGE
RECOMMENDED
CIRCUIT
ELECTRICITY
(EL)
208-240-600V 60 Hz, 3-Ph
CONVERTED TO
480V
THROUGH TRANSFORMER
(OPTIONAL) FD01-600
N/A 24A
(NOTE 7)
40A
(NOTE 7)
1. ALL CONNECTIONS SHOULD BE IN
ACCORDANCE WITH LOCAL CODES.
2. NEUTRAL WIRE NOT REQUIRED.
3. ALWAYS FOLLOW LOCAL ELECTRICAL CODES
AND SAFETY-RELATED WORK PRATICES TO
DETERMINE THE VALUE OF PROTECTION.
4. WIRING ON THE EQUIPMENT TERMINATES AT
A JUNCTION BOX. WIRING BETWEEN JUNCTION
BOX AND BUILDING SERVICE LINES ARE NOT
SUPPLIED BY STERIS.
5. DISCONNECT SWITCHES WITH OFF POSITION
LOCKOUT (SUPPLIED BY OTHERS) MUST BE
INSTALLED IN ELECTRIC SUPPLY LINES NEAR
THE EQUIPMENT.
6. STERIS RECOMMENDS A LIGHT IN SERVICE
AREA.
7. THESE VALUES ARE FOR THE WASHER UNIT,
NOT FOR THE PRIMARY OF THE TRANSFORMER
460-480V 60 Hz, 3-Ph
3/4 in [21 mm] OR 1 in [27 mm]
CONDUIT
24A 40A
380-400-415V 50 Hz, 3-Ph
3/4 in [21 mm] OR 1 in [27 mm]
CONDUIT
24.9A 40A
380-400V 60 Hz, 3-Ph
3/4 in [21 mm] OR 1 in [27 mm]
CONDUIT
29.8A 40A
NETWORK
(N)
OPTIONAL
100/1000 BASE T SUPPORTING
TCP/IP PROTOCOL
RJ45F CONNECTION
8. NETWORK CONNECTION (IF APPLICABLE)
- ACTIVE NETWORK DROP WITH CAT 5/6 CABLE
WITHIN 10FT [3m] OF UNIT
- STATIC OR DHCP RESERVED IP ADDRESS
(FOR EACH UNIT)
- NETWORK CABLE SUPPLIED BY FACILITY
ENGINEERING DATA-RECOMMENDED
TRANSFORMER TRANSFORMER
Page 9 of 10 10232353.F
UTILITY REQUIREMENTS CHART
UTILITY PARAMETER REQUIREMENT NOTES
VENTILATION
EXHAUST
(EX)
CONNECTION SIZE 3 in [76 mm]
OUTSIDE DIAMETER
1. NOT REQUIRED WITH NON-VENTED UNITS.
2. STERIS REQUIRES CORROSION-RESISTANT AND
WATER-TIGHT DUCT:
- MIN OPERATING TEMPERATURE 210°F [99°C]
- SLOPED TOWARDS THE WASHER AND NO DEAD LEGS
- INSTALL DRAIN PART AT LOWEST POINT NEAR UNIT
*STERIS OFFERS VENTILATION P-TRAP
ACCESSORY (FD84-1)
3. EXHAUST FAN NORMALLY OPEN-AUXILIARY CONTACTS
IS AVAILABLE TO SUPPLY A SIGNAL TO THE FACILITY HVAC
CONTROL SYSTEM WHENEVER THE WASHER VENTILATION
EXHAUST FAN IS IN OPERATION.
PRESSURE RANGE 1/2 in [50 mm]
VACUUM AT CONNECTION
OPERATING FLOW RATE 60 SCFM [1.7m³/min]
TEMPERATURE RANGE MAX. 240°F [116°C]
PHYSICAL SPECIFICATIONS
SHIPPING DIMENSION W x H x L 50 in x 91 in x 42 in [1270 mm x 2311 mm x 1067 mm]
1. LEVELING FEET ARE PROVIDED FOR PROPER INSTALLATION.
2. PERMISSIBLE ENVIRONMENTAL CONDITIONS.
THIS EQUIPMENT IS DESIGNED TO GIVE OPTIMAL RESULTS
UNDER THE FOLLOWING CONDITIONS:
- INDOOR USE ONLY;
- ALTITUDE OF OPERATION UP TO 6562 ft [2000 m];
- TEMPERATURE OF 41 TO 104°F [5 to 40°C];
- MAXIMUM RELATIVE HUMIDITY IS 80% FOR TEMPERATURE UP
TO 88°F [31°C], DECREASING LINEARLY TO 50% RELATIVE
HUMIDITY AT 104°F [40°C];
- POLLUTION DEGREE 2: EQUIPMENT MUST BE INSTALLED IN AN
ENVIRONMENT WHERE NORMALLY ONLY NON-CONDUCTIVE
POLLUTION OCCURS BUT WHERE OCCASIONAL, TEMPORARY
CONDUCTIVITY CAUSED BY CONDENSATION CAN BE EXPECTED
(AS DETERMINED ACCORDING TO INTERNATIONAL STANDARD
EN/IEC 61010-1).
3. STERIS ASSUMES NO RESPONSIBILITY FOR CHANGES MADE TO,
OR FAILURE TO OBSERVE THE SPECIFICATIONS ON EQUIPMENT
DRAWING AND NOTE PAGES. SPECIFICATIONS AND
DESCRIPTIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
4. FOR SINGLE WASHER USING STANDARD BARRIER WALL FLANGE
SHIPPING WEIGHT 1000 LB [453 KG]
OPERATING DIMENSION W x H x L 42 in x 80 in x 31 in [1067 mm x 2032 mm x 787 mm]
OPERATING WEIGHT
(WITH WATER AND FULLY LOADED) 1050 LB [476 KG]
NOISE LEVEL:
WEIGHTED EQUIVALENT
SURFACE SOUND PRESSURE LEVEL
60.2 db(A)
CALCULATED AS DESCRIBED
IN ISO 3746.
OPENING AREA FROM CLEAN SIDE
TO SOILED SIDE
(NOTE 4)
170.7 in² [0.11 m²]
CONTINUOUS OPERATION
TYPICAL HEAT LOSS AT 75°F [24°C]
CLEAN SIDE SOILED SIDE TOTAL UNITS
NON-VENTED
UNIT
1878 3808 5686 ± 683 [Btu/Hr]
550 1115 1665 ± 200 [W]
VALUES INCLUDE HEAT LOSS DURING DOOR OPENING FOR LOADING AND UNLOADING OPERATIONS.
"TOTAL" WILL VARY DEPENDING ON DISINFECTION TIME AND TEMPERATURE, DRYING TIME AND
TEMPERATURE AND USE RATE OF UNIT.
T I T L E
EQUIPMENT DRAWING OF
AMSCO® 5052 SINGLE-CHAMBER WASHER/DISINFECTOR
ELECTRIC HEATED, NON-VENTED, UNIT OFFSET FROM WALL
Corporation
SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER
& REVISIONA N/A Vincent Carmichael 10232353
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
Page 10 of 10 10232353.F
| 1
USER MANUAL
WASHER-DISINFECTOR
CUSTOMER
REQUIREMENTS
NORTH AMERICA
ENDODRY™
Storage & Drying Sytem
2 |
50098-678-EN Rev E
© 2019 All rights reserved. This publication is protected by copyright. Copying, disclosure to others, or the use of this publication is prohibited without the express written consent of Medivators Inc.
ADVANTAGE PLUS™
is a trademark of Medivators Inc.
DSD EDGE™
is a trademark of Medivators Inc.
ENDODRY™
is a trademark of Medivators Inc.
All other company or product names referenced in this document are trademarks of their respective owner.
Medivators reserves the right to make changes in the specifications shown herein without notice or obligation. Contact your Medivators representative or Medivators customer service for more information.
| 3SITE REQUIREMENTS
This purpose of this document is to provide the facility with requirements to ensure correct installation and subsequent proper performance of the ENDODRY™ Storage and Drying System.
READ THE ENTIRE DOCUMENT.
APPLICABLE DOCUMENTS
• ENDODRY Storage and Drying System User Manual.
Any deviation from these specifications may cause operational issues that would not be covered by the Warranty.
4 |
BY SIGNING BELOW CUSTOMER ACKNOWLEDGES THAT:
1. Customer reviewed these Site Requirements for the ENDODRY™ Storage and Drying System as indicated in this document.
2. The customer assumes complete responsibility for meeting the specifications and requirements set forth in the Site Requirements documentation to ensure proper installation and performance of the ENDODRY Storage and Drying System. Failure of the customer to comply with these Site Requirements and any deviation from the specifications set forth herein may compromise the functionality of the system, and/or may cause operational issues which will not be covered by the Cantel Medical warranty, and are hereby disclaimed by Cantel Medical.
3. The customer assumes complete responsibility for meeting the specifications and requirements set forth in the Site Requirements documentation by the agreed upon installation date between the Customer and Cantel Medical. If the Cantel Medical installation team encounters any delays due to site requirements not meeting specifications and requirements, the Customer will be charged Medivators current rates for stand-by fees, until the site requirements are met and installation activity resumes; or, if it is determined that the delay results in rescheduling the installation to a later date, the Customer will be charged for all expenses at current Medivators rates (flights, lodging, and car rental, if applicable), and travel and labor time related to the return installation dispatch.
4. If installation is canceled or moved 48 hours prior to the agreed upon installation date, no fee will be charged.
5. For customers who request or accept Medivators space planning suggestions for the site prior to installation (“Space Planning Services”), Customer agrees that the Disclaimer, indicated in this document on Page 9, will apply to such Space Planning Services.
Customer Representative
Title
Signature Date Email
| 5
AIR SUPPLY
1. Quality: ISO 8573-1:2010 class 1.2.1
• Particle Size: Incoming air filtered down to <1 micron in size.
• Moisture Content: Pressure dew point (PDP) of -40°C or better required and no liquid water.
• Oil Content: < 0.01mg of oil per cubic meter of compressed air (liquid, aerosol or vapor oil).
2. Pressure: The below pressures are required at the point of cabinet connection. Facility should consult with their Maintenance Department or their qualified air vendor to identify potential issues with the air supply.
• ENDODRY™ Cabinet for ADVANTAGE PLUS™ Endoscope Reprocessor: 58-145 psi (4-10 bar).
• ENDODRY Cabinet for DSD EDGE™ Automated Endoscope Reprocessor: 72-145 psi (5-10 bar).
3. Volume: The below volumes are required at the point of cabinet connection.
• ADVANTAGE PLUS Endoscope Reprocessor/ENDODRY Cabinet: Minimum requirement of 4.2 scfm (120 l/min ANR) per cabinet.
• DSD EDGE Automated Endoscope Reprocessor/ENDODRY Cabinet: Minimum requirement of 7 scfm (200 l/min ANR) per cabinet.
4. Flexible Air Hose: A 5 foot (1.5 Meter) line is included with each cabinet.
• One end will be pre-configured to connect to ENDODRY™ Drying Cabinet.
• Open end will be ¼” or 6mm inner diameter and it is the responsibility of the facility to make that connection to their air supply line.
The compressors listed below are suggestions that the facility can purchase directly from either the compressor manufacturer or authorized dealer. Medivators is not responsible for air compressor warranty, service and maintenance.
ADVANTAGE HOOKUPS DSD HOOKUPS
# of Cabinets
BeaconMedaes (Requires Additional Dryer)
Powerex (w/ Dryer)
# of Cabinets
BeaconMedaes (Requires Additional Dryer)
Powerex (w/ Dryer)
1 LES03-145T-RD-xxx SES0308TM** 1 LES05-145T-RD-xxx SES0508TM**
2 LES05-145T-RD-xxx SES05058TM** 2 LES10-145RD LSE1504
3 LES07-145T-RD-xxx LSE1504 3 LES15-145RD LSE1504
4 LES07-145T-RD-xxx LSE1504 4 LES20-145RD LSE2005
5 LES15-145RD LSE1504 5 LES20-145RD LSE2005
6 |
ELECTRICAL SUPPLY
• 100-240 VAC ± 10%, single phase, 50/60 Hz, 15 amp circuit (120v), 10 amp circuit (230v).
• Power input: 75W
• A NEMA 5-15 power cord for the North America market and a CEE 7 power cord for the European market is included with the ENDODRY™ Storage and Drying System. The cord is approximately 6 feet (1.8 meters) in length.
• A GFI/RCD protected outlet located on the wall above the ENDODRY Storage and Drying System, see Floor & Wall Section.
• Medivators equipment must be on dedicated circuits.
NETWORKING
• The ENDODRY Storage and Drying System is a networkable piece of equipment and has the capabilities to communicate to other Medivators technologies via a LAN interface (RJ45, 10/100 Mbit).
• A 6.5 foot (2 meter) cable is included with the cabinet.
• A RJ45 wall mounted network jack located on the wall above the ENDODRY Storage and Drying System, see Floor & Wall section.
DIMENSIONS
Shipping Dimensions
• Crate Dimensions: H84”x W47”x D31”
• Crate Weight: 583 lbs.
Reprocessor Dimensions
• Dimensions: H74.8” X W23.6” X D21.3”
• Weight: 375 lbs (170 kg)
FLOOR & WALL
• The floor must be level.
• For optimal user-safety and operation, it is recommended that the ENDODRY Storage and Drying System always be placed directly on the floor, and not on an elevated platform.
• The back of the one-sided ENDODRY Storage and Drying System will be placed flush against the wall. All electrical, network and air connections must be placed a minimum of 78.7 inches (200 cm) off of the floor above the cabinet.
• The two-sided ENDODRY Storage and Drying System is designed to fit into an opening in the wall. The rough opening for a single unit is H75.2” X W24” (191cm x 61cm). All electrical, network and air connections must be placed a minimum of 78.7 inches (200 cm) off of the floor above the cabinet. The electrical, network and air connections must be located on the loading side of the ENDODRY Storage and Drying System.
| 7
.6
21.3"
41.7"
EN
D
O D
R Y
St or ag e an d
D ry in g
Sy st em
TM
El ec tri ca l C on ne ct io n
Ai r C on ne ct io n
N et w or k C on ne ct io n
2 3
O ne
-S id ed V er si on
C 3D
V ie w
M in im um fa ci lit y w al l c on ne ct io ns he ig ht is
8.
7” fr om fl oo r.
O pt io ns fo r D oo rs
O pe n Le ft -O
L O pe n
R ig ht -O
R
B To p Vi ew
A Fr on t 3
D V ie w
.6
.3
3.
9” w w w .e nd oi nf ec tio np re ve nt io n.
co m to d ow nl oa d th e R ev it fil e.
Fo r c la rif ic at io n an d/ or q ue st io ns pl ea se c on ta ct T ec hn ic al
S up po rt at
.8
.4
.4
9.
4.5”12” 4.8”
1 3
.8
8 |
62.2"
21.3"
.6
EN
D
O D
R Y
St or ag e an d
D ry in g
Sy st em
TM
El ec tri ca l C on ne ct io n
Ai r C on ne ct io n
N et w or k C on ne ct io n
2 3
Tw o-
Si de d Ve rs io n (P as s-
Th ru
O pt io ns fo r D oo rs
O pe n Le ft/ O pe n
Le ft
-O
LU
L O pe n
R ig ht /O pe n
Le ft
-O R
U L
O pe n Le ft/ O pe n
R ig ht
O
LU
R O pe n
R ig ht /O pe n
R ig ht
O R
U R
B To p Vi ew
A Fr on t 3
D V ie w
W et
S id e
D ry
S id e
W et
S id e
C 3D
V ie w
W et
S id e D ry S id e
1 3
3.
9"
M in im um fa ci lit y w al l c on ne ct io ns he ig ht is
8.
7” fr om fl oo r.
*M ea su re m en t u si ng a
” w al l.
4.5” 12”4.8”
.6
*1
5.
3"
.8 w w w .e nd oi nf ec tio np re ve nt io n.
co m to d ow nl oa d th e R ev it fil e.
Fo r c la rif ic at io n an d/ or q ue st io ns pl ea se c on ta ct T ec hn ic al
S up po rt at
.8
.4
.4
9.
| 9
SPACE-PLANNING SERVICES
For customers who request or accept Medivators space planning suggestions for the site prior to installation (“Space Planning Services”), Customer agrees that the following Disclaimer will apply to such Space Planning Services:
CUSTOMER ACKNOWLEGES AND ACCEPTS THAT SPACE PLANNING SERVICES ARE OFFERED AND
PROVIDED “AS IS” WITH NO REPRESENTATION OR WARRANTY, EXPRESS OR IMPLIED, OF ANY KIND WHATSOEVER, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO THE ADEQUACY OF ANY DESIGN, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR THAT ANY OF THE SERVICES WILL MEET CUSTOMER’S NEEDS OR REQUIREMENTS OR BE CAPABLE OF IMPLEMENTATION.
IN NO EVENT SHALL MEDIVATORS BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR LOSS OF PROFITS, LOSS OF USE, OR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND, WHETHER OR NOT A PARTY WAS, IS, OR SHOULD BE AWARE OF SUCH LOSS OR DAMAGES.
CUSTOMER AGREES THAT IT WILL RELY ON, USE AND OR OTHERWISE EMPLOY ARCHITECTS, ENGINEERS, CONSTRUCTION PROFESSIONALS AND OTHER VENDORS OR SERVICE PROVIDERS (COLLECTIVELY, “PROJECT PROFESSIONALS”) REGARDING THE FEASIBILITY OR IMPLEMENTATION OF ANYSPACE PLANNING SERVICES PROVIDED BY MEDIVATORS. By accepting the Space Planning Services, (i) Customer agrees to hold Medivators and its affiliates entirely free from any liability, including financial responsibility, for all claims, losses, damages, suits, actions, costs, liabilities, or expenses incurred by Customer or its agents or affiliates as a result of any design defect, any requirement of corrective or other action or its use, reliance on, modification or implementation of any of the Space Planning Services; (ii) Customer acknowledges that Medivators is not a licensed architect or engineer or otherwise in the business of construction or space design and Customer accepts the risks involved in using such Space Planning Services from Medivators; and (iii) Customer agrees to communicate to the Project Professionals the content of all the Space Planning Services including, without limitation, all designs and plans, specifications and attachments, and to have such Project Professionals check, review, verify and approve such content prior to incorporating, using or otherwise implementing any Space Planning Service.
10 |
ENDODRY™ STORAGE AND DRYING SYSTEM
PRE-SITE REQUIREMENTS CHECKLIST
INITIAL AND SIGN AT THE TIME OF PRE-SITE INSPECTION
Customer Site Requirements Criteria Initials
ENDODRY™ Cabinet for ADVANTAGE PLUS™ Endoscope Reprocessor provides air supply of 58-145 psi (4-10 bar).
ENDODRY Cabinet for DSD EDGE™ Automated Endoscope Reprocessor provides air supply of 72-145 psi (5-10 bar).
Air supply provides a flow rate of 4.2 scfm (120 l/min ANR) for the Advantage and 7 scfm (200 l/min ANR) for the DSD.
Air supply maximum particle size is <1 micron, maximum dew point is -40°C, maximum oil content is 0.01 mg/m3.
Air Supply plumbed to the wall a minimum of 78.7 inches (200 cm) off of the floor above the cabinet.
GFI/RCD protected outlet located on the wall a minimum of 78.7 inches (200 cm) off of the floor above the cabinet.
RJ45 wall mounted network jack located on the wall a minimum of 78.7 inches (200 cm) off of the floor above the cabinet (ENDODRY™ Cabinet for ADVANTAGE PLUS™ Endoscope Reprocessor only).
Installation site has a level floor.
Installation site accommodates the dimensions of H74.8” x W23.6” x D21.3” (190cm x 60cm x 54cm)
Customer Site
Customer Representative
Title
Signature Date Email
Serial #
Serial #
Serial #
Serial #
Serial #
Serial #
Medivators Customer and Technical Support: Toll Free: 1-800-444-4729 · FAX: 1-866-421-7696
Medivators BV Sourethweg 11 6422PC Heerlen The Netherlands Tel: +31.45.5.471.471
Cantel Medical Asia/Pacic Pte. Ltd.
1A International Business Park #05-01 Singapore 609933 Tel: +65.6227.9698 www.medivators.com
Medivators Inc.
14605 28th Avenue North Minneapolis, MN 55447 USA Toll Free: +1.800.444.4729
ESCAD Medical GmbH Zur Ohmdwiesen 5 88633 Heiligenberg Germany Tel: +49.7554.9999.500 Fax: +49.7554.9999.558
| Relocate Sketch.pdf |
| AMSCO 5052 Washer footprint and utilities_3681740.pdf |
| Feuille 1 |
| Vues |
| new_view_35 |
| new_view_37 |
| new_view_57 |
| new_view_67 |
| Zones |
| A1 |
| Feuille 2 |
| Vues |
| new_view_55 |
| Zones |
| A1 |
| Feuille 3 |
| Vues |
| new_view_38 |
| new_view_39 |
| new_view_40 |
| Zones |
| A1 |
| Feuille 4 |
| Vues |
| new_view_44 |
| new_view_45 |
| new_view_46 |
| Zones |
| A1 |
| Feuille 5 |
| Vues |
| new_view_41 |
| new_view_42 |
| new_view_43 |
| new_view_65 |
| Zones |
| A1 |
| Feuille 6 |
| Vues |
| new_view_47 |
| Zones |
| A1 |
| Feuille 7 |
| Zones |
| A1 |
| Feuille 8 |
| Zones |
| A1 |
| Feuille 9 |
| Vues |
| new_view_64 |
| Zones |
| A1 |
| Feuille 10 |
| Zones |
| A1 |
EndoDry Site Requirements (004).pdf
File details come from the government source that posted it. Updated .