36C25622R0094 081400 Interior Wood Doors .docx

DOCX document 33 KB Posted

Attached to
Z2DA--Project #502-19-107 - Replace AHU-104 - Construction - 36C25622R0094 Federal contract opportunity
Solicitation number
502-19-107
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

About this file

This document provides specifications for interior wood doors required for the Replace AHU #104 and Ductwork project at the Department of Veterans Affairs Health Care System in Alexandria, Louisiana. The specifications cover flush wood doors with transparent or painted finishes to meet ANSI/WDMA standards. Requirements include extra heavy duty construction with structural composite lumber cores for 44mm thick doors made from premium grade rotary cut white maple or custom grade hardwood faces. Doors must be factory fitted and finished with conversion varnish or catalyzed vinyl per ANSI standards. The related solicitation is for construction services for project number 502-19-107 to replace air handling unit 104 at the Alexandria VA facility, as attached in the request for proposal.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Project #502-19-107 - Replace AHU-104 - Construction - 36C25622R0094, newest first.
File Type Posted
36C25622R0094 ECS Geotechnical Report.pdf PDF
36C25622R0094 0004.docx DOCX document
36C25622R0094 0001.docx DOCX document
36C25622R0094 Project Risk Assessment .pdf PDF
36C25622R0094 260526 Grounding and Bonding.docx DOCX document
36C25622R0094 260519 Low voltage conductors .docx DOCX document
36C25622R0094 312011 Earthwork .docx DOCX document
36C25622R0094 262416 Panelboards.docx DOCX document
36C25622R0094 281300 Physical Access Control System .doc DOC document
36C25622R0094 EXHIBIT A.docx DOCX document
36C25622R0094 262911 Motor Controllers .docx DOCX document
36C25622R0094 316500 Helical Piles.doc DOC document
36C25622R0094 282300 Video Surveillance .docx DOCX document
36C25622R0094 236400 PACKAGED WATER CHILLERS.docx DOCX document
36C25622R0094 233700 AIR OUTLETS AND INLETS.docx DOCX document
36C25622R0094 260541 UNDERGROUND ELEC CONSTRUCTION .docx DOCX document
36C25622R0094 230541 NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT .docx DOCX document
36C25622R0094 230512 GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT.docx DOCX document
36C25622R0094 233100 HVAC DUCTS AND CASINGS.docx DOCX document
36C25622R0094 233600 AIR TERMINAL UNITS .docx DOCX document
36C25622R0094 238216 AIR COILS .doc DOC document
36C25622R0094 230800 COMMISSIONING OF HVAC SYSTEMS.docx DOCX document
36C25622R0094 033000 Cast in Place Concrete.docx DOCX document
36C25622R0094 019100 General Commissioning Requirements .docx DOCX document
36C25622R0094 090600 Schedule for Finishes .docx DOCX document
36C25622R0094 Brand Name JA 502-19-107 Redacted.pdf PDF
36C25622R0094 COVID-19 Safety Protocols for Federal Contractors Rev 2.docx DOCX document
36C25622R0094 280800 Commissioning of Electronic Safety and Security Systems .docx DOCX document
36C25622R0094 000110 VHA Master Specifications Rev 2.docx DOCX document
36C25622R0094 262726 Wiring Devices .docx DOCX document
36C25622R0094 283100 Fire Detection and Alarm .doc DOC document
36C25622R0094 260923 Lighting Controls.docx DOCX document
36C25622R0094 232500 HVAC WATER TREATMENT .docx DOCX document
36C25622R0094 260511 Requirements for ELEC installation.docx DOCX document
36C25622R0094 234000 HVAC AIR CLEANING DEVICES .docx DOCX document
36C25622R0094 238100 DECENTRALIZED UNITARY HVAC EQUIPMENT.docx DOCX document
36C25622R0094 260800 Commissioning of Electrical Systems.docx DOCX document
36C25622R0094 232113 HYDRONIC PIPING .docx DOCX document
36C25622R0094 230923 DIRECT DIGITAL CONTROL SYSTEM FOR HVAC .doc DOC document
36C25622R0094 014500 Quality Control.docx DOCX document
36C25622R0094 013526 Safety Requirements .docx DOCX document
36C25622R0094 099100 Painting .docx DOCX document
36C25622R0094 095100 Acoustical Ceilings .docx DOCX document
36C25622R0094 087100 Door Hardware .docx DOCX document
36C25622R0094 092216 Non-Structural Metal Framing .docx DOCX document
36C25622R0094 096513 Resilient Base and Accessories.docx DOCX document
36C25622R0094 079200 Joint Sealants .docx DOCX document
36C25622R0094 092900 Gypsum Board .docx DOCX document
36C25622R0094 076000 Flashing and Sheet Metal .docx DOCX document
36C25622R0094 015719 Temporary Environmental Controls .doc DOC document
Show all 50

Z2DA--Project #502-19-107 - Replace AHU-104 - Construction - 36C25622R0094 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REPLACE AHU #104 AND DUCTWORK BLDG. 7

DEPARTMENT OF VETERANS AFFAIRS HEALTH CARE SYSTEM-ALEXANDRIA, LA

PROJECT NO.: 502-19-107

SECTION 08 14 00

INTERIOR WOOD DOORS

GENERAL

SUMMARY

Section Includes:

Interior flush wood doors transparent finish.

RELATED WORK

Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS: Paints and Coatings and Composite Wood and Agrifiber VOC Limits.

Section 08 71 00, DOOR HARDWARE: Door Hardware including hardware location (height).

Section 08 11 13, HOLLOW METAL DOORS AND FRAMES: Installation of Doors.

Section 08 71 00, DOOR HARDWARE: Installation of Door Hardware.

Section 09 06 00, SCHEDULE FOR FINISHES: Door Finish.

APPLICABLE PUBLICATIONS

Comply with references to extent specified in this section.

American National Standards Institute/Window and Door Manufacturers Association (ANSI/WDMA):

I.S. 1A13 - Architectural Wood Flush Doors.

ASTM International (ASTM):

E9009(2016) - Laboratory Measurements of Airborne Sound Transmission Loss of Building Partitions and Elements.

Window and Door Manufacturers Association (WDMA):

TM 714 - CycleSlam Test.

TM 814 - Hinge Loading Test.

TM 1014 - Screw Holding Capacity.

SUBMITTALS

Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

Submittal Drawings:

Show size, configuration, and fabrication and installation details.

Indicate project specific requirements not included in Manufacturer's Literature and Data submittal.

Manufacturer's Literature and Data:

Description of each product.

Samples:

Corner section of flush veneered door 300 mm (12 inches) square, showing details of construction, labeled to show grade and type number and conformance to specified standard.

Veneer sample 200 mm by 275 mm (8 inch by 11 inch) showing specified wood species sanded to receive a transparent finish. Factory finish veneer sample where the prefinished option is accepted.

Sustainable Construction Submittals:

Low PollutantEmitting Materials:

Show volatile organic compound types and quantities.

Test Reports: Indicate products comply with specifications.

Screw Holding Capacity Test.

CycleSlam Test.

HingeLoading Test.

Operation and Maintenance Data:

Care instructions for each exposed finish product.

QUALITY ASSURANCE

Manufacturer Qualifications:

Regularly and presently manufactures specified products.

Manufactures specified products with satisfactory service on five similar installations for minimum five years.

DELIVERY

Deliver products in manufacturer's original sealed packaging.

Minimum 0.15 mm (6 mil) polyethylene bags or cardboard packaging to remain unbroken during delivery and storage.

Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, and manufacture date.

Identify door opening corresponding to Door Schedule.

Before installation, return or dispose of products within distorted, damaged, or opened packaging. Retain packaging for door protection after installation.

STORAGE AND HANDLING

Store products indoors in dry, weathertight conditioned facility.

Store doors according to ANSI/WDMA I.S. 1A.

Protect products from damage during handling and construction operations.

FIELD CONDITIONS

Environment:

Product Temperature: Minimum 21 degrees C (70 degrees F) for minimum 48 hours before installation.

Work Area Ambient Temperature Range: 21 to 27 degrees C (70 to 80 degrees F) continuously, beginning 48 hours before installation.

Comply with door manufacturer's instructions for relative humidity.

WARRANTY

Construction Warranty: FAR clause 52.24621, "Warranty of Construction."

Manufacturer's Warranty: Warrant interior factory finished flush wood doors against material and manufacturing defects.

Warranty Period: Lifetime of original installation.

PRODUCTS

PRODUCTS - GENERAL

Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES.

Provide each product from one manufacturer.

Sustainable Construction Requirements:

Low PollutantEmitting Materials: Comply with VOC limits specified in Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS for the following products:

Paints and coatings.

Composite wood and agrifiber.

FLUSH WOOD DOORS

General:

ANSI/WDMA I.S. 1A, Extra Heavy Duty.

Adhesive: Type II.

Core: Structural composite lumber, except when mineral core is required for fire rating.

Thickness: 44 mm (13/4 inches) unless otherwise shown or specified.

Faces:

ANSI/WDMA I.S. 1A.

One species throughout project unless scheduled or otherwise shown.

Transparent Finished Faces: Premium Grade. rotary cut, white maple .

A Grade face veneer.

Match face veneers for doors for uniform effect of color and grain at joints.

Door Edges: Same species as door face veneer, except maple is acceptable for stile face veneer on birch doors.

In existing buildings, where doors are required to have transparent finish, use wood species, grade, and assembly of face veneers to match adjacent existing doors.

Painted Finishes: Custom Grade, mill option close grained hardwood, premium or medium density overlay.

Factory sand doors for finishing.

Wood For Stops, Louvers, Muntins and Moldings for Flush Doors Required to Have Transparent Finish:

Solid wood of same species as face veneer, except maple is acceptable on birch doors.

FABRICATION

Factory machine interior wood doors to receive hardware, bevels, undercuts, cutouts, accessories, and fitting for frame.

Rout doors for hardware using templates and location heights specified in Section 08 71 00, DOOR HARDWARE.

Factory fit doors to frame, bevel lock edge of doors 3 mm (1/8 inch) for each 50 mm (2 inches) of door thickness.

Clearances between Doors and Frames and Floors:

Door Jambs, Heads, and Meeting Stiles: Maximum 3 mm (1/8 inch).

Finish surfaces, including both faces, top and bottom and edges of the doors smooth to touch.

Identify each door on top edge.

Mark with stamp, brand or other indelible mark, giving manufacturer’s name, door’s trade name, construction of door, date of manufacture and quality.

Mark door or provide separate certification including name of inspection organization.

Identify door manufacturing standard, including glue type.

Identify veneer and quality certification.

FINISHES

Field Finished Doors: Seal top and bottom edges of doors with two coats of catalyzed polyurethane or water-resistant sealer.

Factory Transparent Finish:

Factory finish flush wood doors.

ANSI/WDMA I.S. 1A Section F3 Finish System Descriptions for System 5, Conversion Varnish or System 7, Catalyzed Vinyl.

Use stain when required to produce finish specified in Section 09 06 00, SCHEDULE FOR FINISHES.

EXECUTION

PREPARATION

Examine and verify substrate suitability for product installation.

Verify door frames are properly anchored.

Verify door frames are plumb, square, in plane, and within tolerances for door installation.

Protect existing construction and completed work from damage.

INSTALLATION

Install products according to manufacturer's instructions and approved submittal drawings.

When manufacturer's instructions deviate from specifications, submit proposed resolution for Contracting Officer's Representative consideration.

PROTECTION

After installation, place shipping container over door and tape in place.

Do not apply tape to door faces and edges.

Provide protective covering over exposed hardware in addition to covering door.

Maintain covering in good condition until removal is directed by Contracting Officer's Representative.

- E N D -