This document contains a federal solicitation for air duct cleaning services and the related facility drawings. The solicitation is seeking a contractor to clean all existing sheet metal and flex ductwork at the Southeast Louisiana Veterans Health Care System replacement facility in New Orleans, Louisiana. The 1.6 million square foot facility consists of eleven buildings housing patient care, labs, and offices. Contractors must be qualified to work on commercial duct and ventilation systems. The air ducts were last cleaned in 2017-2018 under a previous contract. Drawings accompanying the solicitation annotate the locations and areas of ducts requiring cleaning. No site visit will be offered for this procurement.

View the file

Other files

File Type Posted
S06 Final Amendment 0004 36C25622Q1090 Final CTR Questions PWS Changes.pdf PDF
S06 Final Amendment 0003 36C25622Q1090 0001 Address Drawings Provided.pdf PDF
CEP L02.pdf PDF
OUT L01.pdf PDF
VA garage lobbies 00971-00MH401.pdf PDF
DNT L02 F-G.pdf PDF
RESEARCH 2nd mech plan.pdf PDF
INP L05.pdf PDF
DNT L03 F-G.pdf PDF
Public Elevator Lobbies 00972-00MH402.pdf PDF
OUT L02.pdf PDF
Level 2 F.pdf PDF
DNT L04i D-E.pdf PDF
CEP L03.pdf PDF
OUT L05.zip ZIP file
068-7MH103-N2 CEP.pdf PDF
DNT L02 D-E.pdf PDF
INP L02.pdf PDF
TLR L04.pdf PDF
RESEARCH 3 5 mech plan.pdf PDF
DNT L04 F-G.pdf PDF
065-7MH102-N1 CEP.pdf PDF
PANAM 105.pdf PDF
CEP L04.pdf PDF
067-7MH103-N1 CEP.pdf PDF
OUT L04.pdf PDF
DNT L04i F-G.pdf PDF
DNT L01 D-E.pdf PDF
DNT L03 D-E.pdf PDF
DNT L2.pdf PDF
OUT L01 J2.pdf PDF
DNT L03i F-G.pdf PDF
OUT L07.pdf PDF
DNT L05 F.pdf PDF
03041-3MH701 OP airflow riser.pdf PDF
Concourse Level 4 Interstitual.pdf PDF
064-7MH101-N2 CEP.pdf PDF
OUT L08.pdf PDF
CEP L01.pdf PDF
PANAM 103.pdf PDF
INP L04.pdf PDF
DNT L06 D.pdf PDF
RESEARCH 3rd mech plan.pdf PDF
TLR L02.pdf PDF
RESEARCH East Mechanical.pdf PDF
DNT L01 F-G.pdf PDF
Concourse Level 3.pdf PDF
DNT L04i F-G_01.pdf PDF
OUT L03.pdf PDF
DNT L01i F-G_01.pdf PDF
Show 40 more

Latest 50 of 103 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3MH101H

3MH101J1

2MH101F1

3MH101H

FCU�1

03�1H

SD�42

SD�41

SD�41

SD�41

SD�41

SD�41

SD�41

8x10

RG�42

220 RG�42

220 RG�42

220 RG�42

220 RG�42

220 RG�42

12x10

SD�49

SD�49

SD�49

SD�49

SD�49

SD�49

20x10

20x10

SD�42

SD�42

SD�42

SD�42

SD�41

SD�41

8ø

8ø

6x10

SD�42

8ø 8x12 14x14

12x12

SD�41

SD�41

SD�41

SD�41

SD�11

125 SD�11

SD�11

SD�11

SD�11

14x10 14x10 12x16

8ø

8ø

8ø

8ø

8ø 8ø

8ø

8ø 8ø

8ø 8ø

16x14

8ø

8ø

10x1412x14

8ø

8ø

8ø

8ø

8x10 8ø

8ø

SD�11

125 SD�11

SD�11

8ø

8x12

SD�12

225SD�12

SD�12

SD�12

SD�11

SD�11

SD�12

10ø 10ø

10x12

10ø 10ø

10x14

8ø

10ø

SD�13

275SD�12

10ø

SD�11

SD�11

SD�11

8ø

8ø

8x10

10x12 8ø8ø8ø

SD�11

SD�11

SD�11

20x14

8x12

8x10

18x16

10ø

10ø

SD�11

SD�11

SD�11

SD�11

SD�12

SD�12

SD�13

SD�13

SD�11

20x18

16x8

6x12

8x14

SD�11

RG�81

8ø 8ø

RG�81

8ø

RG�81

RG�81

RG�81

8ø

8øRG�81

RG�81

8ø

8ø

8ø RG�11

RG�11

RG�11

1258ø

RG�11

8ø

RG�11

8ø 12x10

14x20

14x20

12ø

12ø

12ø

12ø

12ø

12ø

26x14

8ø

RG�81

RG�82

10ø 10ø RG�82

SD�11

SD�12

EG�81

8ø

10ø 10ø 10ø 10ø

RG�82

RG�82

RG�82

225 RG�82

10ø

SD�12

SD�12

SD�12

SD�12

SD�12

8ø

8ø

8ø

8ø

12x12

18x16

14ø

10ø

SD�12

SD�12

8ø

T SPEC

1H109

TECH/

CLEAN

1H108

EXAM

1H112

REF:6J203EXAM

1H111

REF:6J203

INTV

1H206

BLOOD

DRAW

1H116

REF:1H120

BLOOD

DRAW

1H120

BLOOD

DRAW

1H117

REF:1H120

BLOOD

DRAW

1H119

REF:1H120

BLOOD

DRAW

1H118

REF:1H120

CHIEF

1H214

INTV

1H201

INTV

1H208

INTV

1H200

T SPEC

1H110

ST

1H210

INTV

1H202

COPY

STOR

1H211

SOILED

1H114

LOBBY

1H100

CIRC

DESK

1H135

FILE/ WRK

1H136

ADMIN

CUBS

1H137

PAT WELL

COORD

1H139

CLASSRM

1H134

CLASSRM

1H130

DEMO KIT

1H132A

COUNSEL

1H142

COUNSEL

1H141

PAT ED

CUBS

1H140

READING

AREA

1H138

SUPRV

1H213

ELEC

1H113A

ELIG

CLERK

1H204

ELIG

CLERK

1H203

ELEV

JP%1

ELEV

JP%3

ELEV

JP%2

ELEV

JP%4

CORR

1H%C03

CORR

1H%C05

STAIR

STH%1

CORR

1H%C02

CORR

1H%C07

EXAM

1H134B

REF:1H130B

EXAM

1H130B

INTV

1H209

INTV

1H207

INTV

1H205

HK

1H115

REF:6J263

CORR

1H%C01

CLOS

1H130A

CORR

1H%C04

MAS:

RECEPT

1H102

WAITING

1H104

PHLEB

RECEPT

1H103

CORR

1H%C06

AISLE

1H%C08

CLOS

1H134A

PSA(2)

1J212

WC

1H101

AISLE

1H%C05A

AISLE

1H%C05B

CLASSRM

1H132

WAITING

1H100A

UNASSIGNED

1H113B

OUTPATIENT

STAIR

1H100C

EG�81

EG�81

RG�14

RG�14

RG�11

RG�11

EG�81

EG�81

125 8ø 8ø

8x10

12x8

10x14

10x14

10x14

SD�14

SD�14

SD�14

SD�14

SD�14

RG�85

RG�84

SD�13

SD�13

14x1412x12

RG�13

14x10

34x16

16x14

RG�25

RG�25

SD�61

8ø

SD�11

8ø

16x16

EG�81

SD�11

RG�85

14ø 16ø14x10

RG�13

12ø8ø

SD�23

450SD�23

S�25 03�1H

S�24 03�1H

S�23 03�1H

S�22 03�1H

S�20 03�1H

S�19 03�1H

S�18 03�1H

S�17 03�1H

S�14 03�1H

S�13 03�1H

S�12 03�1H

S�11 03�1H

S�10 03�1H

S�4 03�1H

S�2 03�1H

S�3 03�1H

S�16 03�1H

S�15 03�1H

S�21 03�1H

SD�11

S�1 03�1H

SD�23

SD�22

46x20 x2 x2 x2 x3

SD�14

14x10

RG�85

14x1014x10

RG�85

RG�85

SD�14

26x16 x1 x2

52x14

12x8

12x8 x2

66x20

8x6

18x6 18x6

16ø 16ø

RG�81

S�9 03�1H

10x6 KITCHEN EXH

DUCT TO STOVE &

RISE UP THRU ROOF

TO GOOSENECK

8ø 10x12

8ø

8ø

8ø

8ø

8ø

8ø

8ø

8ø

8ø

6x12

10x14

RG�82

8x14

8ø

3MH302

8ø 8ø

03 4

03 5

03 6

03 F03 D 03 E

03 7

03 C

Y50

03 XD

16.1

03 1

03 2

03 XG

03 15

03 B.5

03 4.7

03 D.8

Y40

03 6.9

03 6.7

02 YJ

02 5.1

03 XE

03 B

03 3.9

03 A.6

03 B.403 1.7

03 2.7

03 B.1

XG.1

EJ 2

EJ 5

EJ 9

EJ 10

8ø

8ø

8ø

8ø

10x12

14x10

10ø 10ø

26x14

8x14

8ø

8ø

8ø

SD�23

12ø

14x10

6x12 8ø8ø 10x12

10x14

10ø

SD�11

10x12

8ø

12x12 10x12

8ø

8ø

8ø

6x12

16x12

20x18

8ø

8ø

8ø

8ø8ø

S�3 03�1J1

14x18

8ø

8x12

10ø 10ø 8x14

RG�24

x1

SD�14

12ø12ø12ø12ø12ø 12ø 12ø

SD�14

18x20

16x16

8ø x1

14x20

10ø

12ø

SD�23

450 10ø

16x10

S�5 03�1H

S�6 03�1H

14x12

10ø

S�8 03�1H

S�7 03�1H

12x10

8ø

8x12

20x18

12x16

6ø

8ø

14ø

8ø

14ø

14ø

SD�14

SD�14

10x18

10x18

SD�14

14ø

14ø

RG�24

44x16 48x18

8ø

16ø x2 x2 x2

10ø x2 x2

8ø

RG�81

8x12

8ø

8ø

GENERAL NOTES:

1. FOR SYMBOL LISTS, ABBREVIATIONS, AND GENERAL

NOTES THAT APPLY TO ALL DRAWINGS SEE THE

MH�0 SERIES OF DRAWINGS.

2. FOR GENERAL DETAILS SEE THE MH�5 SERIES OF DRAWINGS.

3. FOR CONTROL DIAGRAMS SEE THE MH�8 SERIES OF DRAWINGS.

4. ALL SUPPLY AIR VAV BOXES SHALL BE LOCATED OUTSIDE OF

PATIENT ROOMS. THIS IS NOT APPLICABLE FOR AREAS WITH

INTERSTITIAL SPACE ABOVE.

5. ALL VAV BOXES, (SUPPLY, RETURN, EXHAUST) SHALL BE MOUNTED

NO MORE THAN 18" ABOVE THE CEILING. THIS IS NOT APPLICABLE

FOR AREAS WITH INTERSTITIAL SPACE ABOVE.

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

08 P

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H A L

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

E E T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

X T

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

3MH101-H

BLDG 03 FIRST FLOOR DUCTWORK PLAN - AREA

H

KJS DCDFebruary 29, 2012

03629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING/ PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

I.S.C. GROUP, INC./ IRRIGATION

DAN EUSER WATER ARCHITECTURE, INC./ WATER FEATURE

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP-08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

1/8" = 1'�0"

FIRST FLOOR � DUCTWORK � AREA H

THIS DRAWING HAS BEEN

AFFECTED BY THE BIM

COORDINATION PROCESS.

PLEASE REFER TO THE BIM

COORDINATED SHOP DRAWINGS

FOR DETAILS.

REFER TO SKETCH:

SK-8-1-NJ-3-MH-101-H-1

RFI 07409: Shorten length to 22' and center beneath storefront.