This solicitation is seeking air duct cleaning services for the Southeast Louisiana Veterans Health Care System replacement facility located in New Orleans, Louisiana. The 1.6 million square foot facility consists of eleven buildings housing patient care areas, laboratories, and office spaces. Services are required to clean all existing sheet metal and flex ductwork including grills, registers, and screens throughout the facility. Personnel must be specifically qualified to work on commercial ventilation systems. Similar services were last provided in 2017-2018 under a previous contract. Drawings accompanying the solicitation annotate the locations and areas of ducts requiring cleaning. The Department of Veterans Affairs Veterans Health Administration VISN 16 is the contracting agency.
View the file
Other files
Show 40 more
Latest 50 of 103 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6" CHS&R UP
4" CHS&R UP
3" HWS&R UP
2" HWS&R DN
SD
SD
AFMD
FD
AHU-3
02-2D
36x24
44x24
RF-3
02-2D
RF-2
02-2D
FD
ATC
AFMD
AHU-2
02-2D
AFMD
AFMD-10
02-2D
AFMD-6
02-2D
AFMD-12
02-2D x2 x2
FOR CONTINUATION
CONCOURSE REFER TO DRAWING
0MH-102-A1
CONCOURSE SUPPLY AIR
54x42 UP 42x18 DN
CONCOURSE RETURN AIR
52x36 UP 24x18 DN
SF-3 RF-3
FCU-1
02-2D1
RF-2 SF-2
AFMD AFMD-15
02-2D
FD
FD
GENERAL EXHAUST
24x14 UP
DOAS SUPPLY
26x38 UP
ED PURGE EXHAUST
30x24 UP
DOAS SUPPLY
24x28 UP & DN
ED PURGE EXHAUST
20x28 UP
GENERAL EXHAUST
18x58 UP 18x32 DN
FD
FD
(2)ACD-TP
30x24
30x24 x2
26x38
(2)ACD-TP
ACD
(2)ACD-TP
28x20 x1
28x12 x2
DOAS SUPPLY
36x24 UP
28x20
30x24
20x28
2 1/2" CHR
2 1/2" CHS
2 1/2" CHS
2 1/2" CHR
3" C H R
3" C H S
3" CHR
3" CHS
CORR
2D-C03
NORM
ELEC
2D227A
EMER
ELEC
2D227B
SERVICE
BAY
2D227
SHAFT
SHD03
SHAFT
SHD02
XA
Y20
A.5
AA
AA.2
3.2
3.3
2.7
3.7
A
A.3
02 4
SD-23
12ø
12ø
12x12 OPEN END DUCT
WITH WIRE MESH SCREEN
300 CFM
12x12 OPEN END DUCT
WITH WIRE MESH SCREEN
450 CFM
SD-23
SD-62
16x10
16x14
14x12
14x10 OPEN END DUCT
WITH WIRE MESH SCREEN
500 CFM
R-1 02-2D1
36x24
(2)ACD-TP
FD
FD
FD
SD
02-2D
VFD-3
02-2D
VFD-43
02-2D
VFD-42
02-2D
VFD-2
6" MPR
6" LPR UP
6" MPR UP
3" MPR
6" LPR
1 1/2" LPR
1 1/4" LPR
1 1/4" LPR UP
6" VENT UP 4" PC UP
1" HPR UP
14x14
4" VENT DN TO CONDENSATE PUMP
8" LPR DN TO CONDENSATE PUMP
4" PC
6" VENT
6" LPR
4" VENT DN
1 1/4" LPR
1" HPR
6" M
P R x1
24x20
16x14
26x24
FTK-1
02-2D1
AFMD
AFMD-13
02-2D
AFMD
AFMD-8
02-2D
1-1/2" D FROM AHU-2 DN
TO LEVEL 1
1-1/2" D FROM AHU-3 DN
TO LEVEL 1
CO
CO
3" D UP & DN
2" D
1/ 2" D
1-1/2" D FROM AHU-4 UP
LEVEL 3
1-1/2" D FROM AHU-5 UP TO
LEVEL 3
2" D
CO
CO
1/ 2" H W R
1/ 2" H W S
2MH305
2MH305
EQUIPMENT PAD
12x12 FUME HOOD EXHAUST
UP & DN
3/4" CW
3/ 4" C W
3/ 4" C W
3/4" CW UP AND 1-1/2" DN .
6" L P R
24x14
(2)ACD-TP
(2)ACD-TPACD
1 1/4" HWR
1 1/4" HWS
1 1/4" HWS/R TO CONCOURSE
FOR CONTINUATION REFER TO
0MP102-A1
S-1 02-2D1
56x24
30x30
FD
FD
FD
SD
AFMD
SD
2" LPR
5" CHS&R UP
4" CHS&R DN
3" HWS&R UP
2" HWS&R DN
2" LPS UP
1 1/4" LPR UP & DN
ATCRF-10SF-13RF-9SF-12
AFMD-48
02-2E
AFMD-49
02-2E
AFMD
AFMD-51
02-2E
AFMD-47
02-2E
GENERAL EXHAUST
18x12 UP
DOAS SUPPLY
20x44 UP
DOAS SUPPLY
14x14 UP
DOAS SUPPLY
20x20 UP & DN
GENERAL EXHAUST
18x24 UP 14x22 DN
AFMD-52
02-2E
14x12 ISOLATION
EXHAUST UP
FCU-1
02-2E1
44x20
FD
3" CHS
3" CHR
2 1/2" CHR
2 1/2" CHS
4" C H R
4" C H S
54x22
AFMD-54
02-2E
AHU-13
02-2E
RF-10
02-2E x1
AFMD-56
02-2E
SD-23
SD-23
12ø 12ø
SD-62
x1 x1
14x10 OPEN END DUCT
WITH WIRE MESH
SCREEN. 500 CFM
12x12 OPEN END DUCT
WITH WIRE MESH SCREEN
450 CFM
12x12 OPEN END DUCT
WITH WIRE MESH SCREEN
300 CFM
CAC-1
02-2E1
SD-24
SD-25
22x16
30x12 OPEN END DUCT WITH
1/2" WIRE MESH SCREEN
2100 CFM
20x10 TRANSFER DUCT WITH
1/2" WIRE MESH SCREEN
SD-24
x2
30x12
14x14
AHU-12
02-2E
26x26 DUCT
DOWN TO AHU
RF-9
02-2E
ACD
ED PURGE
20x30 UP
FD
FD
16x10
26x26
20x30
42x16
44x20
TELECOM
2E227A
SERVICE
BAY
2E227
NORM
ELEC
2E227C
EMER
ELEC
2E227D
SECURITY
2E227B
SHAFT
SHE06
SHAFT
SHE07
XA
A.5
AA
5.3
AA.2
6.1
A
1" LPR DN
1" LPR
2" H W S
2" H W R
ACD
4" CHR
4" CHS
2" HWR
2" HWS
2" LPR
02-2E
VFD-12
02-2E
VFD-49
02-2E
VFD-13
02-2E
VFD-50
8" CHS & R UP
4" HPS UP
2" PC UP
1-1/2" D FROM AHU-13
DN TO LEVEL 1
1-1/2" D FROM AHU-12
DN TO LEVEL 1
CO
CO
3" D UP & DN
1-1/2" D FROM AHU-14 UP
TO LEVEL 3
1-1/2" D FROM AHU-15
UP TO LEVEL 3
1 1/2" D
2" D
CO
CO
CO
1 1/4" CHR
1 1/4" CHS
1 1/4" D
C.O.
CO
1 1/4" D
1/ 4" D
2MH306
2MH306
EQUIPMENT PAD
EQUIPMENT PAD
1 1 x1
1 1/4" CHR
1 1/4" CHS
14x12
2" CHR2" CHS
3/4" CW
3/4"CW UP AND
1-1/2" CW DN
A
4" HPS UP
ANCHOR AT
LEVEL 3 SLAB
G G
G
A
18x12
FTK-1
02-2E1
1" MPR
(2)ACD-TP
(2)ACD-TP
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
2MH403
BLDG 02 SECOND FLOOR SERVICE BAY
ENLARGED PLANS - AREA D & E
KJS SLWFebruary 29, 2012
02629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING/ PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
I.S.C. GROUP, INC./ IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC./ WATER FEATURE
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
1/4" = 1'-0"
SECOND FLOOR Enlarged Mechanical Room Area D
SCALE: 1/4" = 1'-0"
SECOND FLOOR Enlarged Mechanical Room Area E
GENERAL NOTES:
1. FOR SYMBOL LISTS, ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH-0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH-5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH-8 SERIES OF
DRAWINGS.
4. FOR VALVE INFORMATION SEE NOTE 30 ON MH002.
INDICATES ROOMS WITH HORIZONTAL CAP.
ALL DUCTWORK AND PIPING ROUTED ABOVE
THE HORIZONTAL CAP EXCEPT WHERE NOTED.
DUCT DROP THRU CAP TO ROOM BELOW.
KEY NOTES:
RFI 3396.3: Install security mesh at duct entering RM 2E227B
CONDENSATE
COOLER
RFI 08308: Condensate coolers required to connection to DCW