36C25620R0073 Dwg. #02963-3PG701-BLDG 3 MEDICAL GAS RISER DIAGRAM.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25620R0073-0001000.docx | DOCX document | |
| 36C25620R0073-011.pdf | ||
| 36C25620R0073-009.xlsx | XLSX spreadsheet | |
| 36C25620R0073-019.docx | DOCX document | |
| 36C25620R0073-007.doc | DOC document | |
| 36C25620R0073-003.docx | DOCX document | |
| 36C25620R0073-006.docx | DOCX document | |
| 36C25620R0073-005.docx | DOCX document | |
| 36C25620R0073-022.pdf | ||
| 36C25620R0073-017.pdf | ||
| 36C25620R0073-002.doc | DOC document | |
| 36C25620R0073-014.pdf | ||
| 36C25620R0073-008.docx | DOCX document | |
| 36C25620R0073-021.docx | DOCX document | |
| 36C25620R0073-012.pdf | ||
| 36C25620R0073-020.pdf | ||
| 36C25620R0073-013.pdf | ||
| 36C25620R0073-018.pdf | ||
| 36C25620R0073-001.docx | DOCX document | |
| 36C25620R0073-004.docx | DOCX document | |
| 36C25620R0073-010.pdf | ||
| 36C25620R0073-015.pdf |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1-1/4"MV UP
1-1/2"O UP
3/4"MA UP
1-1/4"MV DN
1-1/2"O DN
3/4"MA DN
ZVB-3-J1-1
ZVB-3-J1-2
3J237
MGO-16
3J239
MGO-16
3J-C04 3J-C04A
3J245B
MGO-16
ZVB-3-J2-1
3J112
MGO-16
1 1/2"OA
1/2"DA
UP TO 4J244
3J245C
MGO-16
3J245A
MGO16
3J260
MGO-16
1 1/2"OA
1/2"DA
UP TO 4J246
1 1/2"OA
1/2"DA
UP TO 4J248
1 1/2"OA
1/2"DA
UP TO 4J250
1 1/2"OA
1/2"DA
UP TO 4J242
1 1/2"OA
1/2"DA
UP TO 4J240
1 1/2"OA
1/2"DA
UP TO 4J251
1 1/2"OA
1/2"DA
UP TO 4J249
1 1/2"OA
1/2"DA
UP TO 4J247
1 1/2"OA
1/2"DA
UP TO 4J243
1/2"DA
1 1/2"OA
UP TO 4J241
1/2"DA
1 1/2"OA
UP TO 4J262
1 1/2"OA
1/2"DA
UP TO 4J260
1 1/2"OA
1/2"DA
UP TO 4J258
1 1/2"OA
1/2"DA
UP TO 4J256
1 1/2"OA
1/2"DA
UP TO 4J254
1 1/2"OA
1/2"DA
UP TO 4J255
1 1/2"OA
1/2"DA
UP TO 4J257
1/2"DA
1 1/2"OA
UP TO 4J259
1/2"DA
1 1/2"OA
UP TO 4J263
1 1/2"OA
1/2"DA
UP TO 4J268
1 1/2"OA
1/2"DA
UP TO 4J270
1/2"DA
1 1/2"OA
UP TO 4J272
1 1/2"OA
1/2"DA
UP TO 4J273
1 1/2"OA
1/2"DA
UP TO 4J275
1 1/2"OA
1/2"DA
UP TO 4J277
1 1/2"OA
1/2"DA
UP TO 4J278
1 1/2"OA
1/2"DA
UP TO 4J279
1 1/2"OA
1/2"DA
UP TO 4J280
1 1/2"OA
1/2"DA
UP TO 4J281
1 1/2"OA
1/2"DA
UP TO 4J282
DENTAL VACUUM SYSTEM:
OA WET SEPARATOR TANK
DENTAL VACUUM SYSTEM:
INFINITY TANK
1-1/4"DA UP
6"OAE UP
3/4" MA
3/4" O
1" MV
3/4" O
1" MV
1" MV
3/4" O
3/4" MA
1" MV
3/4" O
3/4" MA
1/2" DA
1" DA
1 1/4" DA
3/4" DA
6" OA
1 1/4" DA
1/2" DA
3/4" DA
1" MV
3/4" MA
3/4" O
1/2" DA
3/4" MA
3/4" O 1" MV
3/4" DA
3/4" MA
3/4" O
1" MV
3J299
4" OA
1/2" DA
1/2 " D A
3/4 " D A
3/4 " D A
3/4 " D A
1/2 " D A
3/4" MA
1/2 " D A
1" DA
1 1/2"OA
1/2"DA
UP TO 4J283
1 1/2"OA
1/2"DA
UP TO 4J271
3/4" DA
1/2" DA
3/4" DA
3/4" DA
3/4" DA
1/2" DA
1/2" DA
3/4" DA
3/4" DA
3/4" DA
1/2" DA
3/4" DA
2"MV UP
1-1/2"O UP
3/4"MA UP
1-1/4"MV DN
1-1/2"O DN
3/4"MA DN
ZVB-4-J1-1
4J219
4J235
MGO-16
4J237
MGO-16
ZVB-4-J1-2
4J-C012
4J240
MGO-17
4J242
MGO-17
4J244
MGO-17
4J246
MGO-17
4J248
MGO-17
4J250
MGO-17
4J251
MGO-17
4J249
MGO-17
4J247
MGO-17
4J243
MGO-17
4J241
MGO-17
4J262
MGO-17
4J260
MGO-17
4J258
MGO-17
4J256
MGO-17
4J254
MGO-17
4J255
MGO-17
4J257
MGO-17
4J259
MGO-17
4J263
MGO-17
4J268
MGO-17
4J270
MGO-17
4J272
MGO-17
4J273
MGO-17
4J275
MGO-17
4J277
MGO-17
ZVB-4-J2-1
4J-C07A
ZVB-4-J2-2
AAP-4-J2-2
4J-C08
4J-C08
4J-C08
4J-C08
4J-C08
4J-C09
ZVB-4-J2-3
ZVB-4-J2-4
ZVB-4-J2-5
ZVB-4-J2-6
ZVB-4-J2-7
AAP-4-J2-1
4J278
MG0-18
4J279
MG0-18
4J280
MG0-18
4J281
MG0-18
4J282
MG0-18
4J283
MG0-18
NITROUS OXIDE
MANIFOLD
WIRE "SWITCHOVER"
ALARM POINT TO
MGAP#1 (CEP) &
MGAP#2 (4JCO5A)
TRIPLEX DENTAL OA
VACUUM PUMPS WITH MPC
ENCLOSURE
MCP
(2)HI-LO PRESSURE SWITCHES.
WIRE "MAIN LINE PRESSURE HIGH"
& "MAIN LINE PRESSURE LOW" TO
MGAP#1 (CEP) & MGAP#2 (4JCO5A)
1 1/4"LV UP
8"OAE UP
1 1/4"R UP
1-1/2"DA UP
1-1/4"DA DN
6"OA DN
4J291
TO (2) WORKSTATIONS
4J291
TO (4) WORKSTATIONS
4J291
TO (2) WORKSTATIONS4J293
T-2 (DA)
T-3 (LAB VAC)
4J293
T-2 (DA)
T-3 (LAB VAC)
4J299
4J297
2" MV
1" O
3/4" MA
1 1/2" MV
3/4" O 1" O
1" O
1" MV
1" O
1" MV
1" MV
1" O
3/4" O
1" MV
1" MV
3/4" O
3/4" MA
1" MV
3/4" O
1" MV
3/4" O
1" MV
3/4" O
1" MV
1" MV
3/4" O
1" MV
3/4" O
1" MV
3/4" O
3/4" O
1" MV
1" MV
1 1/2" MV
3/4" O
1" MV
3/4" O
1" MV
1" MV
3/4" O 3/4" O
1" MV
1" MV
3/4" O
3/4" O
1 1/4" MV
3/4" O
1" MV 3/4" O
1" MV
1/2" N2O
1/2" N2O
1/2" N2O
1 1/4" DA
1 1/4" DA
1 1/4" LV
1 1/4" LV
1" LV
1/2" DA
1 1/4" LV
3/4" DA
1" LV
1/2" DA
1 1/4" LV
1/2" DA
1 1/4" LV
1 1/4" DA
1 1/4" MV
3/4" O
1/2" N2O
1 1/4" MV
3/4" O
1/2" N2O 1/2" N2O
1" MV
1" MV
3/4" MA
3/4" O
1" MV
1" MV
1" O
1" MV
3/4" O
3/4" O
1/2" N2O
1" MV
1" WAGD
4J271
3/4 " O
1/2"CA UP
1/2"CA DN
1/ 2" C A
(2)1/2"CA BRANCH LINES,
WITH 1/2"SHUT-OFF VALVE &
PRESSURE REGULATOR.
CONNECT TO EACH CHUTE.
PRIOR TO THE START OF WORK,
THE PLUMBING SUB-CONTRACTOR
SHALL COORDINATE THE EXACT
LOCATION OF THE COMPRESSED AIR
CONNECTIONS WITH THE TRASH AND
LAUNDRY CHUTE ENGINEER AND
CONSTRUCTION MANAGER.
4J-C05A
MGAP#2
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
3PG701
BLDG 3 MEDICAL GAS RISER DIAGRAM
THIRD/FOURTH FLOOR AREA J1/J2
PG ANKFebruary 29, 2012
03629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING/ PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
I.S.C. GROUP, INC./ IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC./ WATER FEATURE
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
N.T.S.
MEDICAL GAS-3RD FLOOR AREA J1/J2
N.T.S.
MEDICAL GAS-4TH FLOOR AREA J1/J2
MG
MG
MG
AREA J1/J2 FLOOR ELEVATIONS:
ROOF: 240'-0"
EIGHTH FLOOR: 221'-0"
SEVENTH FLOOR: 205'-0"
SIXTH FLOOR: 189'-0"
FIFTH FLOOR: 173'-0"
FOURTH FLOOR: 157'-0"
THIRD FLOOR: 138'-0"
SECOND FLOOR: 119'-0"
FIRST FLOOR: 100'-0"
GENERAL NOTES
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1 DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
DUC1
MG
MG
MG
MG
0P503
0P503
0P503
0P508
0P100
0P507
DUC1
DUC1
DUC1
DUC1
MG
MG
File details come from the government source that posted it. Updated .