36C25620R0073-014.pdf
PDF Posted
- Attached to
- C1PB-- CFM - Install Secondary Master Med Gas Panel Federal contract opportunity
- Solicitation number
- 36C25620R0073
About this file
36C25620R0073 Dwg. 02110-2PG105 E, BLDG 2 FIFTH FLOOR MEDICAL GAS PLAN -.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25620R0073-0001000.docx | DOCX document | |
| 36C25620R0073-017.pdf | ||
| 36C25620R0073-002.doc | DOC document | |
| 36C25620R0073-008.docx | DOCX document | |
| 36C25620R0073-021.docx | DOCX document | |
| 36C25620R0073-012.pdf | ||
| 36C25620R0073-011.pdf | ||
| 36C25620R0073-009.xlsx | XLSX spreadsheet | |
| 36C25620R0073-019.docx | DOCX document | |
| 36C25620R0073-007.doc | DOC document | |
| 36C25620R0073-003.docx | DOCX document | |
| 36C25620R0073-006.docx | DOCX document | |
| 36C25620R0073-005.docx | DOCX document | |
| 36C25620R0073-022.pdf | ||
| 36C25620R0073-020.pdf | ||
| 36C25620R0073-013.pdf | ||
| 36C25620R0073-018.pdf | ||
| 36C25620R0073-016.pdf | ||
| 36C25620R0073-001.docx | DOCX document | |
| 36C25620R0073-004.docx | DOCX document | |
| 36C25620R0073-010.pdf | ||
| 36C25620R0073-015.pdf |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUIET
5D136
MECHANICAL
PENTHOUSE
5E227
NORM
ELEC
5E229A
EMER
ELEC
5E229B
SERVICE
BAY
5E229
T
5D140A
PATIENT
5D140
CYLINDER
GAS
5E230
PIPE
CLOSET
5E231
2"N RISE
3/4"NR RISE 34"CO2 RISE
3/4"CO2R RISE
CARBON DIOXIDE
MANIFOLD 3X3
SEE DETAIL ON
DWG. OP508
NITROUS OXIDE
MANIFOLD 11X11
SEE DETAIL ON
DWG. OP508
NITROGEN
MANIFOLD 14X14
SEE DETAIL ON
DWG. OP508
3/4" NOR RISE
2PG405
2PG405
3" MV
2" MA
4" IAI
4"IAI THROUGH ROOF
6"MAI THROUGH ROOF
PENTAPLEX
20 HP, 392 CFM
6" M
A I
QUADRIPLEX MEDICAL
AIR COMPRESSORS
SEE DETAIL ON DWG. OP505
2"O MAIN SERVING BUILDING 2
SEE DWG. 2PG201
FOR CONTINUATION
3"MA & 4"MV TO BUILDING 1
THROUGH CONCOURSE
SEE DWG. 2PG201
FOR CONTINUATION
3/ 4"
C O
2R 3/
4" N
O R
3/ 4"
N R
3/4"NR THROUGH ROOF
3/4"NOR THROUGH ROOF
3/4"CO2R THROUGH ROOF
6" M
V E
6"MV DROP
6"MVE RISE
QUADRIPLEX MEDICAL
VACUUM PUMPS SEE
DETAIL ON DWG. 0P505
6"MVE THROUGH ROOF
QUADRAPLEX (4)15HP
516 CFM
2"IA RISE
4"IAI RISE
TRIPLEX INSTRUMENT AIR
COMPRESSOR SEE DETAIL
ON DWG. 0P505
TRIPLEX, (3)7.5 HP, 33CFM
1 1/4"MA & 1 1/2"MV TO BUILDING 3
THROUGH CONCOURSE
SEE DWG. 2PG201
FOR CONTINUATION
2"N DN
3/4"CO2 DN
1"NO DN
3"MA DN
6"MV DN
2"IA DN
2"O DN
1"NO RISE
3/4"NOR RISE
2" O
LINE PRESSURE ALARM
WIRED TO MASTER GAS
ALARM PANEL AT THE
EMERGENCY DEPARTMENT
OBSERVATION NURSES STATION 2D153
4" MV
3" MA
3"MA DROP
4"MV DROP
3"MV DROP
2"MA DROP
2" IA
2" N 3/4" CO2
2"O DROP
02 E G
02 D C
02 B
02 5
02 7
XA
8.3
F.9
AA
5.3
AA.2
7.6
8.1
7.5
6.1
A
02 F
02 8
C.5
OP505
OP505
OP505
OP508
OP508 1
OP508
3" M
A 6"
M V
2"
IA
2" O
4" M
A
MG
2PG105*D
2PG105*E
2PG105*E
2PG105*F
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
2PG105-E
BLDG 2 FIFTH FLOOR MEDICAL GAS PLAN -
AREA E
RVD CADDFebruary 29, 2012
02629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING/ PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
THIS DRAWING HAS BEEN AFFECTED BY THE BIM
COORDINATION PROCESS. PLEASE REFER TO THE
BIM COORDINATED SHOP DRAWINGS FOR DETAILS.
SEE RFI 07636:
Revises manifold layout to accomodate door change from RFI 03307