Level 1 2' - 6"

Roof 13' - 0"

Site - Varies 0' - 0"

NEW JAMES HARDIE 48" X 120" HARDIE PANEL

CEDARMILL FIBER CEMENT VERTICAL SIDING

WITH COLORPLUS TECHNOLOGY

COLOR: NAVAJO BEIGE

EXISTING TYPE X MOISTURE

RESISTANT VINYL COATED

GYP. BD. FINISH

INTERIOR

EXTERIOR

VA

R

IE

S

VE

R

IF

Y

IN

F

IE

LD

VE

R

IF

Y

IN

F

IE

LD

EXISTING FLOOR FRAMING

SEE STRUCTURAL DRAWINGS

VERIFY ALL FRAMING CONDITIONS IN FIELD

8'

6" (V

.I.

F.

VA

R

IE

S

8" M

IN

FL

AS

H

IN

G

NEW JAMES HARDIE 7-1/4" X 3/4" HARDIE

TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

FLASHING

FLASHING

FLASHING

REMOVE AND RE-USE

EXISTING ROOF GUTTER

FLASHING

SHEET METAL EDGE FLASHING

NEW JAMES HARDIE 3-1/2" X 3/4"

HARDIE TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

A102

A102

NEW JAMES HARDIE 11-1/4" X 3/4"

HARDIE TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

V .I.

F .

EXISTING EPDM ROOFING

VERIFY EXISTING STRUCTURAL CONDITIONS,

WALL & ROOF CONNECTIONS, AND

ROOF MEMBRANE DETAILS IN FIELD

INSTALL NEW 7/16" ORIENTED STRAND BOARD (OSB)

WITH SEALED EDGES TO PREVENT MOISTURE INTRUSION

INSTALL NEW 7/16" ORIENTED STRAND BOARD (OSB)

WITH SEALED EDGES TO PREVENT MOISTURE INTRUSION

Level 1 2' - 6"

Roof 13' - 0"

Site - Varies 0' - 0"

EXISTING TYPE X MOISTURE

RESISTANT VINYL COATED

GYP. BD. FINISH

INTERIOR

VE

R

IF

Y

IN

F

IE

LD

VE

R

IF

Y

IN

F

IE

LD

VA

R

IE

S

8'

6" (V

.I.

F.

VA

R

IE

S

NEW JAMES HARDIE 48" X 120" HARDIE PANEL

CEDARMILL FIBER CEMENT VERTICAL SIDING

WITH COLORPLUS TECHNOLOGY

COLOR: NAVAJO BEIGE

EXTERIOR

EXISTING FLOOR FRAMING

SEE STRUCTURAL DRAWINGS

VERIFY ALL FRAMING CONDITIONS IN FIELD

8" M

IN

FL

AS

H

IN

G

NEW JAMES HARDIE 7-1/4" X 3/4" HARDIE

TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

FLASHING

FLASHING

FLASHING

REMOVE AND RE-USE

EXISTING ROOF GUTTER

FLASHING

SHEET METAL EDGE FLASHING

NEW JAMES HARDIE 3-1/2" X 3/4"

HARDIE TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

NEW JAMES HARDIE 11-1/4" X 3/4" HARDIE TRIM

WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

V .I.

F .

EXISTING WINDOW

NEW JAMES HARDIE 48" X 120" HARDIE PANEL

CEDARMILL FIBER CEMENT VERTICAL SIDING

WITH COLORPLUS TECHNOLOGY

COLOR: NAVAJO BEIGE

NEW JAMES HARDIE 3-1/2" X 3/4"

HARDIE TRIM WINDOW SURROUND

WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

EXISTING EPDM ROOFING

VERIFY EXISTING STRUCTURAL CONDITIONS,

WALL & ROOF CONNECTIONS, AND

ROOF MEMBRANE DETAILS IN FIELD

INSTALL NEW 7/16" ORIENTED STRAND BOARD (OSB)

WITH SEALED EDGES TO PREVENT MOISTURE INTRUSION

Roof 13' - 0"

FL

AS

H

IN

G

0'

8" M

IN

EXISTING EPDM ROOFING

VERIFY EXISTING STRUCTURAL CONDITIONS,

WALL & ROOF CONNECTIONS, AND

ROOF MEMBRANE DETAILS IN FIELD

NEW JAMES HARDIE 48" X 120" HARDIE PANEL

CEDARMILL FIBER CEMENT VERTICAL SIDING

WITH COLORPLUS TECHNOLOGY

COLOR: NAVAJO BEIGE

FLASHING

REMOVE AND RE-USE

EXISTING ROOF GUTTER

FLASHING

NEW SHEET METAL EDGE FLASHING

NEW JAMES HARDIE 3-1/2" X 3/4"

HARDIE TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

NEW JAMES HARDIE 11-1/4" X 3/4"

HARDIE TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

CAULKING

VERIFY EXISTING

WALL FRAMING

CONDITIONS IN FIELD

INSTALL NEW 7/16" ORIENTED STRAND BOARD (OSB)

WITH SEALED EDGES TO PREVENT MOISTURE INTRUSION

Level 1 2' - 6"

INTERIOREXTERIOR

EXISTING FLOOR FRAMING

SEE STRUCTURAL DRAWINGS

VERIFY ALL FRAMING CONDITIONS IN FIELD

NEW JAMES HARDIE 7-1/4" X 3/4"

HARDIE TRIM WITH COLORPLUS TECHNOLOGY

COLOR: HEATHERED MOSS

FLASHING

FLASHING

CAULKING

FL

AS

H

IN

G

0'

8" M

IN

NEW JAMES HARDIE 48" X 120" HARDIE PANEL

CEDARMILL FIBER CEMENT VERTICAL SIDING

WITH COLORPLUS TECHNOLOGY

COLOR: NAVAJO BEIGE

0'

1/

4"

CRAWL SPACE

INSTALL NEW 7/16" ORIENTED STRAND BOARD (OSB)

WITH SEALED EDGES TO PREVENT MOISTURE INTRUSION

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

A102

DETAILED WALL SECTIONS - ENLARGED WALL

SECTIONS

FEMI FEMI04/11/18

629-17-105HAMMOND C.B.O.C. EXTERIOR WALL

REPAIR PROJECT

NEW ORLEANS, LOUISIANA 70119

Owner

1/2" = 1'-0"1

Section 3 - TYPICAL NEW CONDITION @

WALL

1/2" = 1'-0"2

Section 4 - TYPICAL NEW CONDITION @

WINDOW

1" = 1'-0"3

Section 3 - ENLARGED DETAIL @ ROOF &

WALL

1" = 1'-0"4

Section 3 - ENLARGED DETAIL @ WALL &

CRAWL SPACE

NOTES:

HARDIE BOARD SIDING AND ASSOCIATED PRODUCTS ARE BEING USED AS A STANDARD AND PRODUCTS OF EQUAL OR HIGHER GRADE MAY BE USED.

NOTES:

HARDIE BOARD SIDING AND ASSOCIATED PRODUCTS ARE BEING USED AS A STANDARD AND PRODUCTS OF EQUAL OR HIGHER GRADE MAY BE USED.

NOTES:

HARDIE BOARD SIDING AND ASSOCIATED PRODUCTS ARE BEING USED AS A STANDARD AND PRODUCTS OF EQUAL OR HIGHER GRADE MAY BE USED.

NOTES: