About this file

36C25618R0764 A101-TYPICAL EXISTING WALL CONDITIONS.pdf

View the file

Other files

File Type Posted
36C25618C0183-000.docx DOCX document
36C25618R0764-0002000.docx DOCX document
36C25618R0764-0001000.docx DOCX document
36C25618R0764-0001002.pdf PDF
36C25618R0764-0001001.docx DOCX document
36C25618R0764-004.pdf PDF
36C25618R0764-003.pdf PDF
36C25618R0764-005.pdf PDF
36C25618R0764-000.docx DOCX document
36C25618R0764-001.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Level 1 2' - 6"

Roof 13' - 0"

Site - Varies 0' - 0"

EXISTING EPDM ROOFING

EXISTING 1 X 12 M.D.O. BOARD TRIM

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING TRIM

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING 1 X 6 M.D.O. BOARD TRIM

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING WALL PANEL

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING TYPE X MOISTURE

RESISTANT VINYL COATED

GYP. BD. ON INTERIOR OF

WALL TO REMAIN

INTERIOREXTERIOR

VA

R

IE

S

VE

R

IF

Y

IN

F

IE

LD

VE

R

IF

Y

IN

F

IE

LD

EXISTING FLOOR FRAMING

8'

6" (V

.I.

F.

VA

R

IE

S

CRAWL SPACE

Level 1 2' - 6"

Roof 13' - 0"

Site - Varies 0' - 0"

EXISTING TYPE X MOISTURE

RESISTANT VINYL COATED

GYP. BD. FINISH

INTERIOREXTERIOR

VE

R

IF

Y

IN

F

IE

LD

VE

R

IF

Y

IN

F

IE

LD

VA

R

IE

S

8'

6" (V

.I.

F.

VA

R

IE

S

EXISTING EPDM ROOFING

EXISTING 1 X 12 M.D.O. BOARD TRIM

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING TRIM

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING 1 X 6 M.D.O. BOARD TRIM

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING WALL PANEL

WITH STUCCOFLEX FINISH

TO BE REMOVED

EXISTING TYPE X MOISTURE

RESISTANT VINYL COATED

GYP. BD. FINISH TO REMAIN

EXISTING FLOOR FRAMING

CRAWL SPACE

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

A101

EXISTING WALL CONDITIONS

FEMI FEMI04/11/18

629-17-105HAMMOND C.B.O.C. EXTERIOR WALL

REPAIR PROJECT

NEW ORLEANS, LOUISIANA 70119

Owner

1/2" = 1'-0"1

Section 1 - TYPICAL EXISTING

CONDITION @ WALL

1/2" = 1'-0"2

Section 2 - TYPICAL EXISTING

CONDITION @ WINDOW

Sheets
A101 - EXISTING WALL CONDITIONS
A102 - DETAILED WALL SECTIONS - ENLARGED WALL SECTIONS

File details come from the government source that posted it.