Bld 7 1.pdf
PDF 200 KB Posted
- Attached to
- 657A5-26-111, Triennial Electrical Testing
- Solicitation number
- 36C25526R0186
About this file
This document is an Electrical One-Line Diagram and associated schedules for a seismic upgrade and remodel project at the VA Medical Center in Marion, Illinois (Building 7, Phase 3). The drawing details the electrical distribution system, including three main panelboards: MDP (Main Distribution Panel) rated at 400 amps/480V 3-phase 4-wire with MLO (Main Lugs Only), Panel P1 rated at 225 amps/208V 3-phase 4-wire, and Panel P2 rated at 100 amps/208V 3-phase 4-wire. The system is fed from an incoming 12.47 kV primary service stepped down by a 300 kVA transformer to 480V, then further reduced to 208/120V for branch distribution via a 112.5 kVA transformer.
The schedules specify detailed circuit branch assignments with breaker ratings (primarily 20, 25, and 30 amp devices), load descriptions organized by office and functional areas (receptacles for offices 100-134, conference rooms, break rooms, print rooms, lighting circuits, HVAC equipment, and fire/life safety systems), and calculated demand loads with power factor analysis. Key requirements include providing shunt-trip breakers interlocked with the fire alarm system, surge suppression units (TVSS) on both 480V and 208V systems, branch circuit conductor sizing per the included copper conductor and conduit sizing chart (ranging from 12 AWG to 500 MCM depending on breaker amperage and application), and proper grounding per NEC standards. The document includes detailed riser plan notes specifying conductor types, conduit sizes, equipment specifications, and installation requirements for all major feeders and service disconnects. Drawing number EG7-600, dated March 25, 2020, prepared by the design firm for the Department of Veterans Affairs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| EHRM One line 2114 - RECORD DWGS 1.pdf | ||
| one line 2019 1.pdf | ||
| 36C25526R0186 0001.pdf | ||
| Previous Results 1.pdf | ||
| Drawing - Final - 657A5-21-105 VEG 21.08 Upgrade Campus Electrical Grid 1.pdf | ||
| 10-Electrical 42 lab 1.pdf | ||
| Sign in Sheet.pdf | ||
| Equipment Inventory Schedule WITH EE NUMBERS 1.xlsx | XLSX spreadsheet | |
| OR Bld 2 1.pdf | ||
| 36C25526R0186.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL ONE-LINE DIAGRAM
NO SCALE
PANEL
'MDP'
PANEL
'P1'
PANEL
'P2'
13 11
INTERIOREXTERIOR
REV
NO.
REV
NO.
REV
NO.
NOTE
NO.
NOTE
NO.
R
R
R
R
NOTE
NO.
NOTES:
REV:
GENERAL NOTES:
A
SERVICE:
AMP FRAME:
MAINS:
CRT#
SERVICE:
AMP:
CRT#
SERVICE:
AMP:
CRT#
PROVIDE SHUNT-TRIP TYPE BREAKER AND INTERLOCK WITH FIRE ALARM SYSTEM.
PROVIDE RED BREAKER, BREAKER CAPABLE OF BEING LOCKED IN THE ON/OFF POSITION
CIRCUIT ROUTED THRU LIGHTING CONTACTOR
PROVIDE MANF. BREAKER TIE CLIP WHEN SHARING NEUTRALS
CONTRACTOR TO REFERENCE BRANCH CIRCUIT COPPER CONDUCTOR &
CONDUIT SIZING CHART FOR SIZING OF BRANCH CIRCUITS AND OR FEEDERS AT OR BELOW 100 AMPS
NEW
208/120 VOLT , 3 - PHASE , 4 - WIRE
225 AMP
MLO
WITH SUB FEED LUGS
LOAD
DESCRIPTION
REC; OFFICES 100/101
REC; OFFICES 102/103
REC; OFFICES 103/104/105/O.OFF 112
REC; OFFICES 107/1108/O.OFF 112
REC; OFFICE 110/FILE RM 111
REC; PRINT 114 (COPIER)
REC; O.OFF 112/OFFICE 115/116
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
REC; DRINKING F.
NEW
208/120 VOLT , 3 - PHASE , 4 - WIRE
AMP
WITH SUB FEED LUGS
LOAD
DESCRIPTION
REC; RESTROOMS/DIFF. PWR/LAV.
REC; JAN, MECH/TRAP PRMR/BAS
SPARE
SPARE
SPARE
SPARE
SPARE
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
SPARE
SPARE
SPARE
SPARE
NEW
208/120 VOLT , 3 - PHASE , 4 - WIRE
AMP
LOAD
DESCRIPTION
REC; CONF RM 122
REC; CONF RM 122
REC; CONF RM 122
REC; CONF RM 122
REC; CONF RM 122 FLR BOX/TV
REC; CONF RM 122/PROJ.
SPARE
SPARE
SPARE
SPARE
FIRE/SMOKE DAMPERS
SECURITY PANELS
SECURITY DEVICES
FIRE ALARM
SUMP PUMP
RECIRC PUMP
PWR TO MOTORIZED DIFFUSERS
FCU-1 / CU-1
AHU-3 W/ ELEC HT
BRKR
P
BRKR
P
BRKR
P
AMP
AMP
AMP
TOTAL:
PANELBOARD P1 SCHEDULE
A
0.9
0.9
0.9
0.72
0.36
PANELBOARD P1 SCHEDULE
A
1.08
0.72
0.72
0.72
PANELBOARD P1 SCHEDULE
A
0.072
0.72
0.5
0.5
3.2
12.012
LOAD KVA
B
0.9
0.9
0.72
0.72
0.54
LOAD KVA
B
0.72
0.72
0.72
0.72
0.72
LOAD KVA
B
0.72
0.54
0.3
0.5
0.44
2.8
12.68
C
0.9
0.8
0.72
0.72
0.8
C
0.72
0.72
0.72
C
0.72
0.18
0.5
0.8
3.2
2.8
14.3
3PH
3PH
3PH
MOUNTING:
CRT#
MOUNTING:
CRT#
MOUNTING:
CRT#
SURFACE
LOAD
DESCRIPTION
REC; OFFICES 101/102
REC; OFFICES 104/105
REC; OFFICES 106/107
REC; OFFICES 108/109
REC; FILE RM 111/O.OFF 112
REC; PRINT RM 114 CTR
REC; OFFICES 116/117
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OPEN OFFICE 112 PART. FURN
REC; OFFICE 115/116
REC; GENRL 113/114/118 & EXT. FRT
LTG; OPEN OFFICE, OFFICES
LTS; OFFICES / RR / CONF RM
LTG; OPEN OFFICE, OFFICES
LTG; EMERGENCY/ EXIT
LTS; BUILDING EXTERIER
LTS; PARKING LOT
DESCRIPTION
REC; OFFICES 131/132
REC; OFFICE 130/131
SPARE
SPARE
REC; PRINT 133 WIREMOLD
REC; PRINT 133 WIREMOLD
REC; GENERAL PURPOSE
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; OPEN OFFICE 134 PART. FURN
REC; BREAK RM CTR TOP
REC; BREAK RM CTR TOP
DESCRIPTION
REC; BREAK RM DISPOSAL
REC; BREAK RM MICROWAVE
REC; BREAK RM MICROWAVE
REC; BREAK RM MICROWAVE
REC; BREAK RM MICROWAVE
REC; BREAK RM REFRIG.
REC; BREAK RM VENDING
REC; BREAK RM VENDING
REC; BREAK RM WALL
REC; BREAK RM WALL
REC; BREAK RM WALL
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
LIGHTS @
RECEPTACLES @
RECEPTACLES @
LARGEST MOTOR LOAD @
CONTINUOUS LOAD @
OTHER AND NON-CONTINUOUS LOADS @
BRKR
P
SECTION 2
BRKR
P
SECTION 3
BRKR
P
AMP
AMP
AMP
TOTAL:
KVA / PHASE TOTAL:
AMP / PHASE TOTAL:
TOTAL CONNECTED LOAD:
TOTAL CONNECTED CURRENT:
125%:
100%:
50%
125%:
125%:
100%:
TOTAL DEMAND LOAD:
POWER FACTOR:
TOTAL DEMAND CURRENT:
A
0.9
0.9
0.9
0.72
0.72
1.55
0.64
A
0.9
1.08
0.72
0.72
0.72
0.72
A
0.8
1.2
0.8
0.72
14.71
12.012
26.722
222.7
LOAD KVA
B
0.9
0.9
0.72
0.72
0.9
0.55
0.9
LOAD KVA
B
0.72
0.5
0.72
0.72
0.72
0.72
0.36
LOAD KVA
B
1.2
1.2
0.5
0.54
13.49
12.68
26.17
218.1
80.03
222.15
8.18
10.00
24.20
0.00
2.50
6.70
57.17
1.00
158.70
RATING:
LOCATION:
C
0.96
0.54
0.72
0.72
0.72
1.7
1.2
RATING:
LOCATION:
C
0.5
0.72
0.72
0.72
0.72
0.36
RATING:
LOCATION:
C
1.2
0.8
0.54
12.84
14.3
27.14
226.2
KVA
AMPS
KVA
KVA
KVA
KVA
KVA
KVA
KVA
% PF
AMPS
VERIFY A.I.C.
MECHANICAL
3PH
VERIFY A.I.C.
MECHANICAL
3PH
VERIFY A.I.C.
MECHANICAL
3PH
0.0
0.0
0.0
NOTE
NO.
NOTE
NO.
NOTE
NO.
REV
NO.
REV
NO.
REV
NO.
REV
NO.
NOTE
NO.
NOTES:
REV:
GENERAL NOTES:
A
SERVICE:
AMP FRAME:
MAINS:
CRT#
PROVIDE SHUNT-TRIP TYPE BREAKER AND INTERLOCK WITH FIRE ALARM SYSTEM.
CONTRACTOR TO REFERENCE BRANCH CIRCUIT COPPER CONDUCTOR &
CONDUIT SIZING CHART FOR SIZING OF BRANCH CIRCUITS AND OR FEEDERS AT OR BELOW 100 AMPS
NEW
480/277 VOLT , 3 - PHASE , 4 - WIRE
400 AMP
MLO
WATER HEATER
AHU-1 W/ ELEC HEAT
AHU-2 W/ ELEC HEAT
AHU-4 W/ ELEC HEAT
AHU-5 W/ ELEC HEAT
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
BRKR
P
AMP
TOTAL:
PANELBOARD MDP SCHEDULE
A
LOAD KVA
B
C
3PH
4.5
70.5
MOUNTING:
CRT#
DOAS-1
HP-DOAS-1
HP-1 #1
HP-1 #2
HP-DOAS-2
TVSS
XFMR 'T1'
LIGHTS @
RECEPTACLES @
RECEPTACLES @
LARGEST MOTOR LOAD @
CONTINUOUS LOAD @
OTHER AND NON-CONTINUOUS LOADS @
BRKR
P
AMP
TOTAL:
KVA / PHASE TOTAL:
AMP / PHASE TOTAL:
TOTAL CONNECTED LOAD:
TOTAL CONNECTED CURRENT:
125%:
100%:
50%
125%:
125%:
100%:
TOTAL DEMAND LOAD:
POWER FACTOR:
TOTAL DEMAND CURRENT:
A
90.9
PROVIDE W / INTEGRAL TVSS
LOAD KVA
B
90.9
226.68
272.65
0.00
0.00
0.00
0.00
0.00
156.18
226.68
1.00
272.66
RATING:
LOCATION:
C
90.9
KVA
AMPS
KVA
KVA
KVA
KVA
KVA
KVA
KVA
% PF
AMPS
VERIFY A.I.C.
MECHANICAL
3PH
9.3
17.1
17.5
17.5
17.5
1.5
75.78
156.2
70.5
226.7
NOTE
NO.
REV
NO.
REV
NO.
NOTE
NO.
NOTES:
REV:
GENERAL NOTES:
A
SERVICE:
AMP FRAME:
MAINS:
CRT#
CONTRACTOR TO REFERENCE BRANCH CIRCUIT COPPER CONDUCTOR &
CONDUIT SIZING CHART FOR SIZING OF BRANCH CIRCUITS AND OR FEEDERS AT OR BELOW 100 AMPS
NEW
208/120 VOLT , 3 - PHASE , 4 - WIRE
100 AMP
MLO
REC;GENERAL
REC IG; TTB
REC IG; TTB
REC IG; CABLETRAY (RACK)
REC IG; CABLETRAY (RACK)
REC IG; CABLETRAY (RACK)
REC IG; CABLETRAY (RACK)
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
TVSS
BRKR
P
AMP
TOTAL:
PANELBOARD P2 SCHEDULE
A
0.9
0.8
0.8
2.5
LOAD KVA
B
0.36
0.8
1.16
C
0.36
0.8
1.16
3PH
1.5
1.5
MOUNTING:
CRT#
REC; IT COMM. EQ.
REC; IT COMM. EQ.
REC; IT HEAVY DUTY
REC; IT HEAVY DUTY
REC; IT HEAVY DUTY
REC; IT HEAVY DUTY
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
PROVISION / SPACE
LIGHTS @
RECEPTACLES @
RECEPTACLES @
LARGEST MOTOR LOAD @
CONTINUOUS LOAD @
OTHER AND NON-CONTINUOUS LOADS @
BRKR
P
AMP
TOTAL:
KVA / PHASE TOTAL:
AMP / PHASE TOTAL:
TOTAL CONNECTED LOAD:
TOTAL CONNECTED CURRENT:
125%:
100%:
50%
125%:
125%:
100%:
TOTAL DEMAND LOAD:
POWER FACTOR:
TOTAL DEMAND CURRENT:
A
2.5
10.5
88.9
LOAD KVA
1.16
7.16
61.1
26.32
73.06
0.00
10.00
7.41
0.00
0.00
1.50
18.91
1.00
52.49
RATING:
LOCATION:
C
1.16
7.16
61.1
KVA
AMPS
KVA
KVA
KVA
KVA
KVA
KVA
KVA
% PF
AMPS
VERIFY A.I.C.
MECHANICAL
3PH
0.0
1.5
1.5
NOTE
NO.
REV
NO.
107 12
UNLESS OTHERWISE NOTED ON THE DRAWINGS.=*
100 1 AWG
2 AWG
1-1/4"
8 AWG
8 AWG
1"
1-1/2"
1-1/4"
1-1/2"
1-1/4"
1-1/2"
1-1/4"
CONDUCTOR SIZE
BRANCH CIRCUIT COPPER CONDUCTOR
4 AWG
6 AWG
4 AWG
3 AWG
8 AWG
6 AWG
8 AWG
OVERCURRENT
PROTECTION DEVICE
RATING (AMPS)
12 AWG
12 AWG
10 AWG
10 AWG
SIZE
CONDUCTOR
REQUIRED
3/4"
3/4"
3/4"
3/4"
8 AWG
8 AWG
10 AWG
10 AWG
1"
1"
1"
10 AWG
10 AWG
10 AWG
1-1/4"
1"
3/4"
1"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
WIRE + GND.
SINGLE PHASE 2
CONDUIT SIZE
AND CONDUIT SIZING CHART
10 AWG
10 AWG
12 AWG
12 AWG
EQUIPMENT
GROUNDING
3/4"
3/4"
3/4"
3/4"
CONDUIT SIZE
SINGLE PHASE 3
WIRE + GND.
3/4"
1-1/4"
1"
1"
3/4"
3/4"
3/4"
1-1/4"
1-1/4"
1-1/4"
1"
3/4"
1"
3/4"
THREE PHASE 4
3/4"
3/4"
3/4"
3/4"
THREE PHASE 3
CONDUIT SIZE
WIRE + GND.
3/4"
3/4"
3/4"
3/4"
WIRE + GND.
CONDUIT SIZE
=* ALL CONDUCTORS SIZED ON THE POWER RISER DIAGRAM OR IN BRANCH CIRCUIT CONDUCTOR TABLE ARE BASED ON 3 CURRENT
CARRYING CONDUCTORS IN A RACEWAY OR CABLE. CONDUCTORS SHALL BE DERATED IN ACCORDANCE WITH THE NEC IF 4 OR MORE
CONDUCTORS ARE PLACED IN A RACEWAY OR CABLE.
UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL BRANCH CIRCUITS AND FEEDERS TO BE PROVIDED WITH A NEUTRAL WIRE.=*
RISER PLAN NOTES
1. INCOMING PRIMARY (3) COPPER FEEDERS, TAP SHIELD/PVC, SHIELDED 15KV, UL TYPE
MV-105, 133% INSULTION, 220 MILS, SINGLE CONDUCTOR, REFERENCE ELECTRICAL SITE
PLAN FOR ADDITIONAL INFORMATION.
2. PROVIDE & INSTALL 300 KVA, CONCRETE PAD MOUNTED TRANSFORMER, 12.47 kV TO 480V.
REFERENCE TRANSFORMER DETAIL.
3. 4"C, 3-#500 & 1-#3 GROUND WIRE
4. PROVIDE & INSTALL, 400A/3P FUSED SERVICE ENTRANCE RATED SAFETY SWITCH IN A
NEMA 3R ENCLOSURE, FUSE @ 400A. REFERENCE MAIN SERVICE ENTRANCE GROUNDING
DETAIL SHEET EG7-501.
5. 4"C, 4-#500 & 1-#3 GROUND WIRE
6. PROVIDE & INSTALL SURFACE MOUNTED TVSS UNIT (CURRENT TECHNOLOGY MODEL
CG60-480/277-3GY) FEED THROUGH 60A, 3-PHASE CIRCUIT BREAKER. LOCATE AS CLOSE
AS POSSIBLE TO TOP OF PANEL. CONDUCTORS SHALL NOT HAVE SHARP BENDS. INSTALL
TVSS UNIT PER MANUFACTURER RECOMMENDATION.
7. PROVIDE & INSTALL 1-1/2"C, 3-#1/0 & 1-#6 GROUND WIRE.
8. PROVIDE & INSTALL 200A/3P NON-FUSED DISC. SWITCH NEMA 3R
9. PROVIDE & INSTALL NEMA 3R 112.5 KVA ON A CONCRETE PAD. 480/208-120 VOLT, 3Ø, 4W
TRANSFORMER. GROUND PER NEC. 250 W/#3 GROUND WIRE.
10. PROVIDE & INSTALL 2-1/2"C, 4-#4/0 & 1-#4 GROUND WIRE.
11. PROVIDE & INSTALL 200A/3P FUSED SAFETY DISC. SWITCH IN A NEMA 3R ENCLOSURE.
FUSE AT 200 AMPS. FEED OUT OF BACK OF DISCONNECT AND DIRECLTY INTO PANEL 'P1',
WITH CONDUCTORS (NOTE 10).
12. PROVIDE & INSTALL 1-1/4"C, 4-#4 & 1-#8 GROUND WIRE.
13. PROVIDE & INSTALL 100A/3P FUSED SAFETY DISC. SWITCH IN A NEMA 3R ENCLOSURE,
FUSE AT 80 AMPS
14. PROVIDE & INSTALL SURFACE MOUNTED TVSS UNIT (CURRENT TECHNOLOGY MODEL
CG40-120/208-3GY) FEED THROUGH 30A, 3-PHASE CIRCUIT BREAKER. LOCATE AS CLOSE
AS POSSIBLE TO TOP OF PANEL. CONDUCTORS SHALL NOT HAVE SHARP BENDS. INSTALL
TVSS UNIT PER MANUFACTURER RECOMMENDATION.
X
E L E
C T
R I C
A L
S C
H E
D U
L E
S
R
I S
E R
D I A
G R
A M
EG7-600
COA No.
COPYRIGHT C 2019 Project No.
184005671-002 19.6309.00
MARCH 25, 2020
VA PROJECT NO: 657-345
Dwg: Of:# #
DRAWING NO:
PR
O
JE
C
T
TI
TL
E:
B U
IL
D
N
IG
N U
M B
ER
D R
A W
N
C H
EC
K
ED
LO
C
A
TI
O N
SE
IS
M
IC
U
PG
R A
D E
A N
D R
EM
O
D
EL
B U
IL
D
IN
G
P
H A
SE
3-
B U
IL
D
IN
G
V A
U I L
D I N
G
A
M C
M
A R
I O
N
I L
D R
A W
IN
G
T
IT
LE
A
PP
R O
VE
D
N E
T W
O R
K
D
E P
A R
T M
E N
T O
F V
E T
E R
A N
S A
F F
A
IR
S V
E T
E R
A N
S A
D M
IN
IS
T R
A T
IO
N
M E
D
IC
A L
C E
N T
E
M
E D
I C
A L
C
E N
T E
R
S E
I S
M
C
P G
R A
D
N
M
O D
E L
B U
I L D
I N
G
P
H A
M
O D
U L A
R
B U
I L D
I N
G
V
A M
C
M
A R
I O
N
I L
DATE:
SU
B
M
IS
SI
O
N D at e
D R
A W
I N
G
I N
D E
X
L E
G E
N D
X X
X
G
G
N
E R
L
F O
R M
A T
I O
N
F
C
H I T
E C
T U
R A
L
F
L O
O
A
N
C
H I T
E C
T U
R A
L
C
E I L
I N
G
P
L A
N
F
E
S
A F
E T
Y
P
L A
N
A
I V
A
N
A
I V
H
E D
U L
E
D I R
E C
T I O
N
S
E M
E N
T
F L O
S
T
R
T H
U
T H
W
W
S
T
B U
I L D
I N
G
D R
A W
I N
G
Department of Veterans Affairs n ne ttl et on bo nn er s pr in gs , k s
3.
2.
p h : 3
.4
.9 fx de si gn ar ch ite ct ur e in te rio rs
A W
L B
C D
B
L H
FO
R
C O
N
ST
R U
C
TI
O N bn b
| Sheets and Views |
| 19.6309.00_EG7-600-45 EG7-600 |
File details come from the government source that posted it. Updated .