UE
OE
M/G 400A/3P
M/G 400A/3P
C
PC
R
TS
T
100/3
100/3/70
100/3/70/1
100/3/CB
PP
J
GF
OR
OR
OR
EPO
AM
VM
DM
ST
KK
GFR
M
SPD
R
CU
MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT
PLUMBING PLAN NOTE CALL OUT
ELECTRICAL, TECHNOLOGY OR FIRE ALARM
PLUMBING EQUIPMENT DESIGNATION
EQUIPMENT DESIGNATION TAG
OWNER FURNISHED, CONTRACTOR INSTALLED
EQUIPMENT DESIGNATION
NEW WORK TO EXISTING WORK CONNECTION POINT
DETAIL REFERENCE
SECTION CUT DESIGNATION
ELECTRICAL: (AFF, AFG UNLESS NOTED OTHERWISE)
LP1
A1
LIGHT FIXTURE, CEILING MOUNTED
a
LIGHTING TRACK WITH TRACK LIGHT FIXTURES
LIGHT FIXTURE, POLE MOUNTED
LIGHT FIXTURE, WALL MOUNTED
EMERGENCY BATTERY PACK LIGHT FIXTURE,
WALL MOUNTED
EMERGENCY BATTERY PACK LIGHT FIXTURE,
CEILING MOUNTED
EXIT SIGN, WALL MOUNTED, FACE/ARROWS AS INDICATED
EXIT SIGN, CEILING MOUNTED, FACE/ARROWS AS INDICATED
EMERGENCY LIGHT FIXTURE, CEILING MOUNTED
A1E a
A1 a
A1
A1
X1E
X1E
Y1E
Y1E
HOMERUN TO PANELBOARD, ARROWS INDICATE
NUMBER OF CIRCUITS, TICK MARKS INDICATE
NUMBER OF CONDUCTORS. DESIGNATIONS ARE
PANELBOARD AND CIRCUIT NUMBERS.
UNSWITCHED HOT CONDUCTORS SHOWN LEADING
NEUTRAL CONDUCTOR
NEUTRAL CONDUCTOR
SWITCHED HOT CONDUCTORS SHOWN TRAILING
GROUND CONDUCTOR
EQUIPMENT GROUNDING CONDUCTOR IN RACEWAY
ISOLATED GROUNDING CONDUCTOR IN RACEWAY
CONCEALED RACEWAY
EXPOSED RACEWAY
RACEWAY TURNING DOWN
RACEWAY TURNING UP
EQUIPMENT TERMINATION
LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT)
LIGHT FIXTURE, BOLLARDA1
RECEPTACLE, SIMPLEX, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, NEMA 5-20R, UNO
RECEPTACLE, DOUBLE-DUPLEX, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, CEILING MOUNTED, NEMA 5-20R, UNO
RECEPTACLE, SPECIAL PURPOSE
RECEPTACLE, TWIST-LOCK
RECEPTACLE, DUPLEX, FLOOR MOUNTED, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, DROP CORD, NEMA 5-20R, UNO
RECEPTACLE, MOUNTED 6" ABOVE COUNTER,
TYPE AS INDICATED ABOVE
RECEPTACLE DESIGNATIONS AS FOLLOWS:
SWITCH, SINGLE POLE
SWITCH DESIGNATIONS AS FOLLOWS:
OCCUPANCY SENSOR, CEILING MOUNTED
POWER PACK FOR LIGHTING CONTROL
JUNCTION BOX
RECEPTACLE ON EMERGENCY POWER
RECEPTACLE, ISOLATED GROUND TYPE
MULTI-OUTLET, SURFACE RACEWAY, 24" ON CENTER,
NEMA 5-20R, UNO
SWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION
PANELBOARD ON HOUSEKEEPING PAD
PANELBOARD, RECESS MOUNTED
PANELBOARD, SURFACE MOUNTED
TRANSFORMER
DISCONNECT SWITCH, NON-FUSED, 100/3 INDICATES
AMPERES/POLES, CB = CIRCUIT BREAKER TYPE
DISCONNECT SWITCH, FUSED, 100/3/70 INDICATES
AMPERES/POLES/FUSE, CB = CIRCUIT BREAKER TYPE
COMBINATION DISCONNECT SWITCH WITH MOTOR STARTER
100/3/70/1 INDICATES AMPERES/POLES/FUSE/ NEMA STARTER
SIZE, NF = NON-FUSED, CB = CIRCUIT BREAKER TYPE
MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED,
3-POLE, UNO
CONTACTOR
PHOTOCELL
RELAY
TIME SWITCH
LOW-VOLTAGE TRANSFORMER
PUSH BUTTON, TYPE AS NOTED
VARIABLE FREQUENCY DRIVE WITH DISCONNECT SWITCH
100/3/70 INDICATES AMPERES/POLES/FUSE SIZE,
NF = NON-FUSED, CB = CIRCUIT BREAKER TYPE
UNDERGROUND ELECTRIC LINE
MULTI-SERVICE FLOOR BOX/POKE-THRU WITH POWER/DATA,
TYPE AS NOTED AND/OR SCHEDULED
CABINET, RECESS MOUNTED
CABINET, SURFACE MOUNTED
RECEPTACLE, DUPLEX, GROUND-FAULT CIRCUIT
INTERRUPTER, NEMA 5-20R, UNO
MULTI-SERVICE POWER POLE WITH POWER/DATA,
TYPE AS NOTED AND/OR SCHEDULED
OVERHEAD ELECTRIC LINE
MUSHROOM TYPE PUSH BUTTON, TYPE AS NOTED
PLAN NOTE CALL OUT
TRANSFER SWITCH, RATINGS AS INDICATED
ATS = AUTOMATIC TRANSFER SWITCH
TX#
600AF
3P
500AT
400AS
3P
225AF
275KW STANDBY
480Y/277V, 3PH, 4W
GENERATOR, SEPARATELY DERIVED
SOURCE, TYPE AND RATINGS AS INDICATED
275KW STANDBY
480Y/277V, 3PH, 4W
GENERATOR, NON-SEPARATELY DERIVED
SOURCE, TYPE AND RATINGS AS INDICATED
DRAWOUT CIRCUIT
BREAKER, RATINGS
AS INDICATED
600AF
3P
500AT
CIRCUIT BREAKER,
RATINGS AS
INDICATED
LPS-R
FUSED DISCONNECT
SWITCH, RATINGS
AS INDICATED
400AS
3P
225AF
LPS-R
COMBINATION FUSED
SWITCH AND STARTER,
RATINGS AS
PANELBOARD,
SINGLE-SECTION,
RATINGS PER
SCHEDULES
PANELBOARD,
MULTI-SECTION,
RATINGS PER
SCHEDULES
NEMA 1
AMMETER
VOLTMETER
COMBINATION DIGITAL
SHUNT-TRIP RELAY
KIRK-KEY INTERLOCK
GROUND-FAULT RELAY
UTILITY METER
RELAY
SURGE PROTECTION
AMMETER/VOLTMETER
DEVICE
AUTOMATIC TRANSFER SWITCH WITH BYPASS
TYPE AND RATINGS AS INDICATED
VARIABLE FREQUENCY
DRIVE WITH
DISCONNECT, RATINGS
GROUND CONNECTION
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
GROUND CONNECTION
WITH TEST WELL
CONTACT, OPEN
CONTACT, CLOSED
MOTOR
FEEDER TAGCAPACITOR
SURGE ARRESTER
HEATER
225A 3P
NEMA 1
INDICATED
COMBINATION CIRCUIT
BREAKER AND
STARTER, RATINGS AS
INDICATED AS INDICATED
225A 3P
200A 3P
ATS#
200A 3P
ATS#
TRANSFORMER
TX#
TRANSFORMER,
SHIELDED
200A DEAD-FRONT ELBOW
600A DEAD-FRONT ELBOW
DEAD-FRONT SPLITTER
FAULT INDICATOR
LIGHTNING PROTECTION AIR TERMINAL
LIGHTNING PROTECTION CABLE CONNECTION
LIGHTNING PROTECTION GROUND ROD
LIGHTNING PROTECTION CONDUCTOR
MTS = MANUAL TRANSFER SWITCH
EP-101
EP-101
LIGHTNING PROTECTION SYMBOLS
ELECTRICAL ONE-LINE DIAGRAM SYMBOLS
M (CONT'D)
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
OS# = CEILING MOUNTED OCCUPANCY SENSOR,
REFER TO OCCUPANCY SENSOR SCHEDULE
2 = TWO-POLE WALL SWITCH
3 = THREE-WAY WALL SWITCH
4 = FOUR-WAY WALL SWITCH
D = DIMMER SWITCH
OS# = OCCUPANCY SENSOR WALL SWITCH, REFER
TO OCCUPANCY SENSOR SCHEDULE
P = SINGLE-POLE, SINGLE-THROW PILOT LIGHT
WALL SWITCH
K = KEYED WALL SWITCH
M = MOTOR RATED SWITCH
WP = WEATHER PROOF SWITCH AND COVER
C = CLOCK HANGER
E = EMERGENCY POWER
GF = GROUND FAULT CIRCUIT INTERRUPTER
IG = ISOLATED GROUND
S = SWITCHED
TR = TAMPER RESISTANT
WP = WEATHER PROOF COVER
WR = WEATHER RESISTANT
XP = EXPLOSION PROOF
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
Y1E = LIGHT FIXTURE TYPE "Y1E" REFER TO LIGHT
FIXTURE SCHEDULE
Y1E = LIGHT FIXTURE TYPE "Y1E" REFER TO LIGHT
FIXTURE SCHEDULE
X1E = LIGHT FIXTURE TYPE "X1E" REFER TO LIGHT
FIXTURE SCHEDULE
X1E = LIGHT FIXTURE TYPE "X1E" REFER TO LIGHT
FIXTURE SCHEDULE
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
A1E = LIGHT FIXTURE TYPE "A1E" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
NL = NIGHT LIGHT
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
NL = NIGHT LIGHT
= ARROW INDICATES AIMING DIRECTION
LIGHTING SYMBOLS
POWER EQUIPMENT SYMBOLS
WIRING DEVICE SYMBOLS
AUDIBLE APPLIANCES (CENTERLINE) 84"
ALARMS (TOP) 48"
ANNUNCIATOR PANELS (TOP) 48"
CLOCK OUTLETS (CENTERLINE) 84"
CONTROLS (TOP) 48"
EXIT SIGNS (WALL-MOUNTED, BOTTOM) 80"
FIRE ALARM ANNUNCIATOR PANEL (DISPLAY) 60"
FIRE ALARM BELL (EXTERIOR) 120"
FIRE ALARM CONTROL PANEL/UNIT (DISPLAY) 60"
INTERCOM (AFEA ONLY) 36"
INTERCOMS (TOP) 48"
PANELS & PANELBOARDS (TOP) 72"
PULL STATIONS (TOP) 48"
PHOTOCELLS 144"
RECEPTACLES (BOTTOM) 18"
RECEPTACLES, EXTERIOR (BOTTOM) 24"
RECEPTACLES, GARAGES (BOTTOM) 26"
RECEPTACLES IN EQUIPMENT ROOMS (TOP) 48"
RECEPTACLES ABOVE COUNTERTOPS (TOP) 44"
REMOTE INDICATING LIGHT, EQUIPMENT ROOMS (TOP) 48"
REMOTE INDICATING LIGHT, FINISHED AREAS (TOP) CEILING
SAFETY SWITCHES & STARTERS 48"
SWITCHES (TOP) 48"
TELEPHONE/DATA/TV OUTLETS (BOTTOM) 18"
VISIBLE APPLIANCES (CENTERLINE) 84"
X
W
V
U
T
S
R
CIRCUITING SYMBOLS
ANNOTATION STANDARD MOUNTING HEIGHTS
P
O
N
M
L
K
J
I
H
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FABL FIRE ALARM BELL
FABX FIRE ALARM BOX
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FI FILM ILLUMINATOR
FIXT FIXTURE
FLA FULL LOAD AMPS
FLEX FLEXIBLE METALLIC CONDUIT
FLUOR FLUORESCENT
FO FIBER-OPTIC
FP FIRE PROTECTION
FT FEET OR FOOT
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G
F
E
D
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMCP EMER. MONITORING CONTROL PANEL
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
ETD EXISTING TO BE DEMOLISHED
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DISTR DISTRIBUTION
DISTR PNL DISTRIBUTION PANEL
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
C CONDUIT
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER
CLF CURRENT LIMITING FUSE
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
C
B
A
ABBREVIATIONS
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VCM VERTICAL CABLE MANAGER
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
TC TIME CLOCK
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
REC RECESSED
REQD REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
RU RACK UNIT
N NEUTRAL
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
KV KILOVOLT
KVA KILOVOLT AMPERE
KVAH KILOVOLT AMPERE PER HOUR
KVAR KILOVOLT AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
KWHM KILOWATT HOUR METER
JB JUNCTION BOX
J-BOX JUNCTION BOX
XFER TRANSFER
XFMR TRANSFORMER
XP EXPLOSION PROOF
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LTCP LOCAL TEMPERATURE CONTROL PANEL
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
W WATT
WH WATER HEATER
WP WEATHERPROOF
IESNA ILLUMINATION ENGINEERING SOCIETY
OF NORTH AMERICA
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
G OR GND GROUND OR GENERATOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
SCC SHORT CIRCUIT CAPACITY
SES SERVICE ENTRANCE SECTION
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, PULL BOX, OR
PUSHBUTTON
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PCB POLYCHLORINATED BIPHENYL
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
POD POWER OPERATED DAMPER
POE POWER OVER ETHERNET
PP PATCH PANEL
PT POTENTIAL TRANSFORMER
PTRV POWER TYPE ROOF VENTILATION
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
1P SINGLE POLE
1PH SINGLE-PHASE
3P THREE POLE
3PH THREE-PHASE
3W THREE WIRE
4W FOUR WIRE
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER, AUTOMATIC
FREQUENCY CONTROL, OR
AVAILABLE FAULT CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMB OR A AMBIENT
AMP AMPERE
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
HCM HORIZONTAL CABLE MANAGER
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISH FLOOR
BIL BASIC INSULATION LEVEL
BLDG BUILDING
BLK BLOCK
BPIP BOILER PLANT
INSTRUMENTATION PANEL
BRKR BREAKER
BYP BY PASS
IC INSULATION CONTACT
ES EMERGENCY SHUNT RELAY
USB = DUPLEX RECEPTACLE WITH (2) USB OUTLETS
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL LEGEND
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-E-000
589-A5-19-116
BID DOCUMENTS
Revision # Date
A1
AREA OF DEMOLITION
1314 12 11 10 8 7 6 5.1 4.1
U
T
S
R
Q
P
O
N
M
9 5
A1
10 8 7 6
U
T
S
R
PROJECTS OFFICE
A107
CLEAN STORAGE
A138
DINING/ACTIVITY
A139
NURSE MANAGER
A105
ELEC. CLOSET
A139E
FIRE CLOSET
A139F
WOMEN'S STAFF RESTROOM
A104
CLOSET
A105A
UNIVERSAL WASTE STORAGE
A101A
LOBBY
A101
ENTRY
A100
CORRIDOR
A1-1
MECHANICAL
A140M
NURSE PRACTITIONER
A141
STAFF BREAKROOM
A142
REPORT ROOM
A143
CHART ROOM
A144
TUB ROOM
A170A
SHOWER
A170 RESTROOM
A170B
SOCIAL ROOM
A171
SUPPLY ROOM
A172
DOCK AREA
A173 TRAY DELIVERY
A174
CONFERENCE
A174A
HOUSEKEEPING
A179
MEN
A180
RECREATIONAL THERAPY
A178
SOILED LINEN
A175
STAIR 1
A175A
HOUSEKEEPING
A176
STORAGE
A178A
RESTROOM
A177B
WOMEN'S LOCKER ROOM
A176A
MEN'S LOCKER ROOM
A177
RESTROOM
A175B
CORRIDOR
A1-1
CORRIDOR
A1-1
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL LIGHTING
DEMOLITION PLAN - A WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-ELD101A
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL LIGHTING DEMOLITION PLAN - A WING
ELECTRICAL PLAN NOTES:
1 REMOVE ALL LIGHT FIXTURES, LIGHTING CONTROLS AND
CIRCUIT CONDUCTORS BACK TO THE PANELBOARDS WITHIN THE
AREA OF WORK.
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
6. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC AND BASED
OFF OF AVAILABLE INFORMATION AND MAY NOT REPRESENT ALL
DEVICES/EQUIPMENT REQUIRED FOR DEMOLITION. FIELD VERIFY
ALL EXISTING DEMOLITION WORK PRIOR TO SUBMISSION OF
PROPOSAL.
GENERAL NOTES:
1/8" = 1'-0"2
ELECTRICAL LIGHTING DEMOLITION PLAN - BASEMENT
WING A
BASEMENT
DEDUCT ALTERNATE NOTES:
IF DEDUCT ALTERNATE IS ACCEPTED, OMIT DEMOLITION OF ALL
CIRCUITING, LIGHTING, AND LIGHTING CONTROLS OUTSIDE OF THE
AREA SHOWN. DEMOLISH ALL LIGHTING AND LIGHTING CONTROLS
WITHIN THE AREA SHOWN. TRACE CIRCUIT TO CLOSEST FIXTURE ON
CIRCUIT NOT BEING REMOVED. REMOVE ALL CIRCUITING BACK TO
THIS POINT. IF CIRCUIT ONLY FEEDS LIGHTS BEING DEMOLISHED,
DEMOLISH CIRCUITING BACK TO PANELBOARD AND UPDATE
PANELBOARD TO REFLECT "SPARE".
A1.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
OF WORK AS DEFINED ON ARCHITECTURAL SHEET 6-GI-105.
AREA OF DEMOLITION
12 11 10 8 7 6
L
K
J
H
G
F.1
F
E.1
E
D
C
B
A
5 4 3 2 1
MDS COORDINATOR
A137
HOUSEKEEPING SUPERVISOR
A136
SOCIAL WORKER
A135
DIETICIAN
A134
SUPPLY ROOM
A108
STORAGE
A108A
CORRIDOR
A1-3
PHYSICAL THERAPY
B129
RESTROOM
B126
STORAGE
B129A
KITCHEN
B128
STORAGE
B127
CORRIDOR
DCDR7
ENGINEERING SERVICE
B124
CHIEF ENG. ASSISTANT
B123C
ENGINEERING SERVICE CHIEF
B123B
ENGINEERING SERVICE MANAGER
B123A
ENGINEERING
B123
PROGRAM ANALYST
B122
ENGINEERING ADMINISTRATION
B121
STORAGE
B120
WOMEN STAFF RESTROOM
B118
ELEC. CLOSET
B119
STORAGE
B117
CLINICAL PHARMACIST
B116
OFFICE
B115
OFFICE
B114
OFFICE
B113
OSH MANAGER
B112C
SAFETY & EMERGENCY MGMT
B112B
GEMS COORDINATOR
B112A
PROGRAM SUPPORT ASSIST.
B112
WOMEN STAFF RESTROOM
B110
PALLIATIVE CARE COORD.
B109
PATIENT TRANSFER COORD.
B108C
OFFICE
B108B
ELEC. CLOSET
B108E
STORAGE
B130
STORAGE
B133
PROJECTS OFFICE
A107
CORRIDOR
B1-4
CORRIDOR
B1-4
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL LIGHTING
DEMOLITION PLAN - B WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-ELD101B
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL LIGHTING DEMOLITION PLAN - B WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
6. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC AND BASED
OFF OF AVAILABLE INFORMATION AND MAY NOT REPRESENT ALL
DEVICES/EQUIPMENT REQUIRED FOR DEMOLITION. FIELD VERIFY
ALL DEMOLITION WORK PRIOR TO SUBMISSION OF PROPOSAL.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 REMOVE ALL LIGHT FIXTURES, LIGHTING CONTROLS, CIRCUIT
CONDUCTORS AND LIGHTING CIRCUIT CONDUIT BACK TO THE
PANELBOARDS WITHIN THE AREA OF WORK.
2 ELECTRICAL CLOSET TO REMAIN UNTIL LIGHTING POWER CAN
BE RELOCATED FOR THE EXISTING PHYSICAL THERAPY ROOM.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
EA
BLANKS
A1 & A2
(ETD)
(ETD)
(ETD)
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
A1
AREA OF DEMOLITION
6E (ETD) EMDB (ETR)
MSB (ETR)
B6S (ETR)
ES
BLANK
(ETD)
(ETD)
(ETD)
MTS
(ETR)
ATS (ETR)
FACP
(ETR)
F/O
(ETR)
EXISTING CONDENSER
WATER PUMP TO BE
DEMOLISHED.
(ETD)
B6
8, 10, 12
ES
(ETD)
EXISTING DOMESTIC WATER
HEATER TO BE DEMOLISHED.
EXISTING MED VACUUM
PUMP TO BE DEMOLISHED.
EXISTING AIR COMPRESSOR
TO BE DEMOLISHED.
EXISTING WATER SOFTENER
TO REMAIN
EXISTING CHILLER TO BE
ABANDONED IN PLACE.
ES
2, 4, 6
B6
20, 22, 24
ES
7, 9, 11
400/3
A1
10 8 7 6
U
T
S
R
CLEAN STORAGE
A138
DINING/ACTIVITY
A139
ELEC. CLOSET
A139E
FIRE CLOSET
A139F
ENG SERVICE
A139S
PROJECTS OFFICE
A107
LOBBY
A101
UNIVERSAL WASTE STORAGE
A101A
MEN
A180
WOMEN
A102
HOUSEKEEPING
A179
WOMEN'S STAFF RESTROOM
A104
MEN'S STAFF RESTROOM
A103
CONFERENCE
A174A
HOUSEKEEPING
A176
SOILED LINEN
A175
WOMEN'S LOCKER ROOM
A176A
MEN'S LOCKER ROOM
A177
CORRIDOR
A1-1
HOUSEKEEPING
A139A
TRAY DELIVERY
A174
DOCK AREA
A173
CLOSET
A105A
NURSE MANAGER
A105
SOCIAL ROOM
A171
STORAGE
A178A
RECREATIONAL THERAPY
A178
MECHANICAL
A140M
SHOWER
A170 RESTROOM
A170B
STAFF BREAKROOM
A142
REPORT ROOM
A143
CHART ROOM
A144
TUB ROOM
A170A
NURSE PRACTITIONER
A141
SUPPLY ROOM
A172
IT CLOSET
C149
RESTROOM
A175B
RESTROOM
A177B
CORRIDOR
A1-2
ENTRY
A100
STAIR 1
A175A
1314 12 11 10 8 7 6 5.1 4.1
U
T
S
R
Q
P
O
N
M
L
9 5
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL POWER DEMOLITION
PLAN - A WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EPD101A
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL POWER DEMOLITION PLAN - A WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-001 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
6. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC AND BASED
OFF OF AVAILABLE INFORMATION AND MAY NOT REPRESENT ALL
DEVICES/EQUIPMENT REQUIRED FOR DEMOLITION. FIELD VERIFY
ALL EXISTING DEMOLITION WORK PRIOR TO SUBMISSION OF
PROPOSAL.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 EXISTING IT ROOM AND EQUIPMENT TO REMAIN. THIS ROOM IS
TO REMAIN OPERATIONAL THROUGHOUT THE PERIOD OF WORK.
EXISTING INFRASTRUCTURE EXTENDING FROM THIS ROOM,
THROUGH B WING AND SERVING OTHER SPACES IS TO REMAIN
INTACT AND OPERATIONAL. PHASE DEMOLITION OF EXISTING
POWER AND PROVISION OF NEW POWER TO MINIMIZE DOWN
TIME. COORDINATE WITH VA COR AND VA OI&T.
2 REMOVE ALL EXISTING ELECTRICAL POWER DEVICES AND
CIRCUIT CONDUCTORS BACK TO THE PANELBOARDS WITHIN
THE AREA OF WORK.
3 REMOVE EXISTING PANELBOARD AND FEEDER BACK TO THE
UPSTREAM DISTRIBUTION EQUIPMENT.
4 EXISTING WALL MOUNTED BAS DATA SWITCH TO REMAIN.
PROTECT EQUIPMENT DURING CONSTRUCTION.
5 EXISTING WALL MOUNTED DATA ENCLOSURE TO REMAIN.
PROTECT EQUIPMENT DURING CONSTRUCTION.
6 EXISTING WALL MOUNTED CAMDEX SECURITY ENCLOSURE TO
REMAIN. PROTECT EQUIPMENT DURING CONSTRUCTION.
7 EXISTING WALL MOUNTED FIBER TERMINATION UNIT TO REMAIN.
PROTECT EQUIPMENT DURING CONSTRUCTION.
1/8" = 1'-0"2
ELECTRICAL POWER DEMOLITION PLAN - BASEMENT
DEDUCT ALTERNATE NOTES:
IF DEDUCT ALTERNATE IS ACCEPTED, OMIT DEMOLITION OF ALL
CIRCUITING, RECEPTACLES, AND OTHER ELECTRICAL DEVICES
OUTSIDE OF THE AREA SHOWN. DEMOLISH ALL CIRCUITS WITHIN
THE AREA SHOWN BACK TO PANELBOARD FED FROM. UPDATE
PANELBOARD SCHEDULE TO REFLECT "SPARE".
A1.
WING A
BASEMENT
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
B1 & B2
BLANKS
EB
EB-1
(ETD)
(ETD)
(ETD)
(ETD)
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD ETD ETD
ETD ETD ETD ETD ETD
ETD ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
ETD
AREA OF DEMOLITION
EM-TEMP
B-TEMP
6-E-401
MDS COORDINATOR
A137
HOUSEKEEPING SUPERVISOR
A136
STORAGE
A108A
SOCIAL WORKER
A135
DIETICIAN
A134
SUPPLY ROOM
A108
STORAGE
B133
STORAGE
B130
PHYSICAL THERAPY
B129
CORRIDOR
DCDR7
RESTROOM
B126
STORAGE
B129A
KITCHEN
B128
STORAGE
B127
ELEC. CLOSET
B119
WOMEN STAFF RESTROOM
B118
STORAGE
B120
ENGINEERING ADMINISTRATION
B121
ENGINEERING SERVICE
B124
CHIEF ENG. ASSISTANT
B123C
PROGRAM ANALYST
B122
ENGINEERING
B123
ENGINEERING SERVICE CHIEF
B123B
ENGINEERING SERVICE MANAGER
B123A
ELEC. CLOSET
B108E
FIRE CLOSET
B108F
OFFICE
B108B PATIENT TRANSFER COORD.
B108C PALLIATIVE CARE COORD.
B109
WOMEN STAFF RESTROOM
B110
PROGRAM SUPPORT ASSIST.
B112
GEMS COORDINATOR
B112A
SAFETY & EMERGENCY MGMT
B112B
OSH MANAGER
B112C
OFFICE
B113
OFFICE
B114
OFFICE
B115
CLINICAL PHARMACIST
B116
STORAGE
B117
CORRIDOR
B1-4
CORRIDOR
B1-5
PROJECTS OFFICE
A107
12 11 10 8 7 6
L
K
J
H
G
F.1
F
E.1
E
D
C
B
5 4 3 2
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL POWER DEMOLITION
PLAN - B WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EPD101B
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL POWER DEMOLITION PLAN - B WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
6. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC AND BASED
OFF OF AVAILABLE INFORMATION AND MAY NOT REPRESENT ALL
DEVICES/EQUIPMENT REQUIRED FOR DEMOLITION. FIELD VERIFY
ALL EXISTING DEMOLITION WORK PRIOR TO SUBMISSION OF
PROPOSAL.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 REMOVE ALL EXISTING ELECTRICAL POWER DEVICES, CIRCUIT
CONDUCTORS AND POWER CIRCUIT CONDUIT BACK TO THE
PANELBOARD WITHIN THE AREA OF WORK.
2 REMOVE EXISTING PANELBOARD AND FEEDER BACK TO THE
UPSTREAM DISTRIBUTION EQUIPMENT.
3 ELECTRICAL CLOSET TO REMAIN UNTIL POWER CAN BE
RELOCATED FOR THE EXISTING PHYSICAL THERAPY ROOM.
4 DISCONNECT AND REMOVE POWER TO PUBLIC ADDRESS
SYSTEM ENCLOSURE AFTER ENCLOSURE HAS BEEN
RELOCATED. REFER TO TECHNOLOGY DRAWINGS FOR
ADDITIONAL INFORMATION.
5 DISONNECT AND REMOVE POWER TO NURSE CALL SYSTEM
PANEL AFTER PANEL HAS BEEN RELOCATED. REFER TO
TECHNOLOGY DRAWINGS FOR ADDITIONAL INFORMATION.
6 PROVIDE TEMPORARY PANELBOARD AS PART OF PHASE #2.
REFER TO 6-EP101B FOR ADDITIONAL INFORMATION.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
AREA OF DEMOLITION
ETD
ETD
ETD
A1
1314 12 11 10 8 7 6 5.1
U
T
S
R
Q
P
O
N
M
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL POWER DEMOLITION
ROOF PLAN - A WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EPD102A
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL POWER DEMOLITION ROOF PLAN - A WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
6. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC AND BASED
OFF OF AVAILABLE INFORMATION AND MAY NOT REPRESENT ALL
DEVICES/EQUIPMENT REQUIRED FOR DEMOLITION. FIELD VERIFY
ALL EXISTING DEMOLITION WORK PRIOR TO SUBMISSION OF
PROPOSAL.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 REMOVE ALL EXISTING ELECTRICAL POWER DEVICES AND
CIRCUIT CONDUCTORS BACK TO THE PANELBOARDS WITHIN
THE AREA OF WORK.
DEDUCT ALTERNATE NOTES:
IF THE ALTERNATE IS ELECTED, NO DEMOLITION WORK WILL BE
PERFORMED FOR THIS ROOF AREA.
A1.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
AREA OF DEMOLITION
ETD
12 11 10 8 7 6
L
K
J
H
G
F.1
F
E.1
E
D
C
B
A
5 4 3 2 1
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL POWER DEMOLITION
ROOF PLAN - B WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EPD102B
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL POWER DEMOLITION ROOF PLAN - B WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
6. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC AND BASED
OFF OF AVAILABLE INFORMATION AND MAY NOT REPRESENT ALL
DEVICES/EQUIPMENT REQUIRED FOR DEMOLITION. FIELD VERIFY
ALL EXISTING DEMOLITION WORK PRIOR TO SUBMISSION OF
PROPOSAL.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 REMOVE ALL EXISTING ELECTRICAL POWER DEVICES AND
CIRCUIT CONDUCTORS BACK TO THE PANELBOARDS WITHIN
THE AREA OF WORK.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
PP PP PP PP PP
PP
PP PP PP PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
ES
PP
PP
ES
ES
ES
PP
PPES
ES
A3D A3D
A3D A3D A3D A3D A3D
A3DE
A3D A3D A2D A2D
A2D A2D A2D A2D
A2D A2D
A2D A2D
A2D A2D
A2D A2D
A2D
A2D
A3D
A3D
A3D
A3D
A3DE
A3D
A3D
A3D A3DE
A3D A3DE
A3DE
A2D
A2D A2D
A3D
A3D
A3 A2D
STORAGE
A120
DIETICIAN
A121
LACTATION / PUMP
A122
REPORT ROOM
A119
HOSPICE APRN
A118
ACNS
A117
PHARM D
A124
ASST NURSE MNGR
A116
REC THERAPY OFFICE
A125
EXAM
A126
GEC PHYSICIAN
A129
REC THERAPY
A115
ELEC
A111
CONFERENCE
A130
LEARNER OFFICE
A131
STAIR
A135
BREAK ROOM
A132
TESTING
A134
EXAM
A136
NURSE MED
A137
EXAM, BARIATRIC
A138
FAMILY TLT
A102
ED SUPPLY ROOM
A139
BARIATRIC TLT
A103
RECEPTION
A101
STORAGE
A104
STAFF TOILET
A105
STAFF TOILET
A106
MDS / RESTOR OFFICE
A107
TESTING / INTERN
A108
GEROPSYCH
A109
CORRIDOR A
ACDR1
CORRIDOR A
ACDR3
EXAM
A135
PT/OT STOR
A128
SOCIAL WORK
A123
TOILET, BARIATRIC, SHOWER
A133
B1 B1E B1 B1 B1 B1E B1 B1 B1 B1E B1 B1
B1E
B1
B1
B1
B1E
B1
B1E
B1
B1
B1
B1E
B1
B1
B1
B1E
B1E
F1
F1
RC1
LVOD LVOD
PS
RC1
LVOD
PS
RC1
PS PS PS
PS PS PS PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
RC1
LVOD LVOD
RC1 RC1
LVOD
RC1
LVOD
OS1
LVOD
RC1
LVOD
RC1
LVOD
RC1
LVOD
RC1
LVD
RC1
RC1
LVOD
RC1
LVOD
RC1
LVOD RC1
LVOD
RC1
LVD
OS1
D3
RC1
LV3
LVOD
RC1
RC1
OS1
OS1
D1 D1
D1 D1
OS1
D1 D1 a ab
OS2
OS2
OS2
OS2
OS2
OS2
OS2
OS2
OS2 OS2
OS2
OS2
OS2
ab
LVD
RC1
OS1
D1
D1
OS1
OS1
F1
A3DA3D
A2D
OS1
LV3
A3D
A2D
OS2
OS2
OS2
PS
PS
RC1
RC2
OS1
OS1
OS1
OS1
OS1
RC1
OS1
RC2
D2D D2D
OS1
OS1
RC1
OS1
A1
OS1
F2E
A2D A2D
A2D
A2D
F1E
F1E
D2D
D2D
PS
PS
D1D D1D
D1DE
D1D
D1D D1D
D1D
D1DE
D1DD1D
B1
B1D B1D
D1D
D1D D1D
D1D
D1DD1DD1D
D1D
D1
D1
D1
D1
LVD
LV1
W1E
OS1
OS1
LVD
LVD
X1E X1E
X1E
X1E
X1E
OS1
B1
PT / OT
A110
F1E
A2D
D1
D1
LVD
D1D
D1D
D1D
D1D
D1D
D1D
D1D
D1D
D1D
D1D
D1
D1
A3D
RC1
RC2
LVD LVD
HAC
A127
A1 & A2
A1 & A2
A1 & A2
PS
LS-A
A1 & A2
LVD
LVD
LVD
LVD
A1 & A2 (NEW)
EQ-A (NEW)
LS-A (NEW)
EQ-A-T (NEW)
X1E a b a
EQ-A
a a a a a a a a a a a a a a b b b b b b b b b b
(PART)
(PART)
VESTIBULE
A100
D1D D1D
D1D D1DE
b b a a a a b b a a a
RC2
A3D
OS1
X1E a
PS
A1
A1 & A2
A2D
OS1
RC1
IT
A114
PS
RM.
A126
EQ-A
RM.
A138
LVD
LVD
LVOD
LV1
LVD
LVD
PT / OT
A110
LV1
LVD
b
LV1
1314 12 11 10 8 7 6 5.1 4.1
U
T
S
R
Q
P
O
N
M
L
9 5
X1E
LVD
F2E F2 F2E
F2 F2E F2
F2E F2
F2 F2E
F2E
F2ESTAIRS
EQ-A
A1 & A2
MSB2 (NEW)
EMDB2 (NEW)EMDB (ETR)
ATS2 MSB (ETR)
ATS (ETR)
MTS2 (NEW)
MTS
(ETR)
FACP
(ETR)
F/O
(ETR)
(PART)
(PART)
400/3
Y1E
B6 (NEW)
S (ETR)
A1
10 8 7 6
U
T
S
R
AREA WAY
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL LIGHTING PLAN -
A WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EL101A
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL LIGHTING PLAN - A WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 REFER TO DETAIL 1, SHEET 6-E-701 FOR WIRING DIAGRAM OF
ALL TYPICAL ROOM CONTROLLERS WITH SWITCHES,
OCCUPANCY SENSORS AND DAYLIGHT SENSORS.
2 REFER TO DETAIL 2, SHEET 6-E-701 FOR WIRING DIAGRAM OF
TYPICAL OFFICE LIGHTS WITH SWITCHES, OCCUPANCY
SENSORS AND DAYLIGHT SENSORS.
3 REFER TO DETAIL 5, SHEET 6-E-701 FOR WIRING DIAGRAM OF
ALL EXAM ROOM LIGHTS WITH SWITCHES.
4 REFER TO DETAIL 6, SHEET 6-E-701 FOR WIRING DIAGRAM OF
CORRIDOR LIGHTS WITH SWITCHES, OCCUPANCY SENSORS
AND DAYLIGHT SENSORS.
5 REFER TO DETAIL 2, SHEET 6-E-702 FOR WIRING DIAGRAM OF
RECEPTION ROOM A101 AND VESTIBULE ROOM A100 LIGHTS
WITH SWITCHES, OCCUPANCY SENSORS AND DAYLIGHT
SENSORS.
6 REFER TO DETAIL 3, SHEET 6-E-702 FOR WIRING DIAGRAM OF
CONFERENCE ROOM A130 WITH SWITCHES, OCCUPANCY
SENSORS AND DAYLIGHT SENSORS.
7 REFER TO DETAIL 2, SHEET 6-E-701 FOR WIRING DIAGRAM OF
LACTATION/PUMP ROOM A122 WITH SWITCHES, OCCUPANCY
SENSORS AND DAYLIGHT SENSORS. LOCATE CONTROLLER IN
ADJACENT ACCESSIBLE CEILING.
8 REFER TO DETAIL 6, SHEET 6-E-702 FOR WIRING DIAGRAM OF
EXAM ROOM A138 LIGHTS WITH SWITCHES, OCCUPANCY
SENSORS, AND DAYLIGHT SENSORS.
9 REFER TO DETAIL 5, SHEET 6-E-702 FOR WIRING DIAGRAM OF
HAC ROOM 127, GEROPSYCH ROOM A109 AND ED SUPPLY ROOM
A139 WITH SWITCHES.
10 REFER TO DETAIL 4, SHEET 6-E-701 FOR WIRING DIAGRAM OF
PT/OT ROOM A110 CONTROLLERS WITH SWITCHES, OCCUPANCY
SENSORS AND DAYLIGHT SENSORS.
1/8" = 1'-0"2
ELECTRICAL LIGHTING PLAN - BASEMENT
WING A
BASEMENT
DEDUCT ALTERNATE NOTES:
IF DEDUCT ALTERNATE IS ACCEPTED, OMIT ALL CIRCUITING,
LIGHTING, AND LIGHTING CONTROLS OUTSIDE OF THE AREA SHOWN.
PROVIDE CIRCUITING, LIGHTING, AND LIGHTING CONTROLS WITHIN
THE AREA SHOWN. TIE NEW CIRCUITS INTO EXISTING PANELBOARD
A1 AND A2. PROVIDE NEW 20A BREAKERS AS REQUIRED.
A1.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
PP
PP
PP
PP
PP
PPPPPPPP
PPPP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
ES
PP
PP
PP
PP
PP
PP
ES
PP ES
ES
PP
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
D2D D2D
REC THERAPY OFFICE
B132
RESIDENT
B135
RESIDENT
B131
RESIDENT
B137
RESIDENT
B136
RESIDENT
B124
RESIDENT
B125
HAC
B128
RESIDENT [BARIATRIC]
B119
RESIDENT
B120
RESIDENT
B121
RESIDENT
B122
SOCIAL WORKER
B113
NURSE MNGR
B112
STAFF BREAK
B115
GERIATRIC PSYCHIATRIST
B111
APRN
B110
SHARED OFFICE / REPORT
B129
RESIDENT
B123
COMPUTER LOUNGE
B118
TOILET [BARIATRIC]
B119A
RESIDENT
B126
KITCHEN
B109
NURSE STATION
B102
DINING & DAY ROOM
B108
STAFF TOILET
B116
CLINICAL NURSE LEADER
B114
CORRIDOR B
BCDR5
CORRIDOR B
BCDR2
CORRIDOR B
BCDR4
CORRIDOR B
BCDR3
CORRIDOR B
BCDR1
EXAM ROOM
B117
ELEC
B101
MEDS
B100
SOILED HOLDING
B106
LAUNDRY
B127
CLEAN SUPPLY
B104
RESIDENT
B130
TOILET
B130A
PS
B1
PS
PS
PS
PS
B1
B1E
B1
B1
B1
B1
B1
B1
B1E
B1
B1 B1
B1
B1 B1E B1 B1 B1 B1E B1 B1 B1 B1E B1
B1
B1
B1
B1
B1E
B1
D2D
D2D D2D
D2D
D2D D2D
D2D D2D D2D D2D
D3
D3
D1
D1
D1
D1
D1 D1
D1 D1
D3 D3
D1 D1
D1 D1
D3 D3
D1D1
D1 D1
D3D3D3
D1
D1
A3D
A3D
A1
B1B1E
A1
A1D
D1D D1D D1DE D1D D1D
D1DE D1D D1D D1D D1DE
D1DE
D1D
A3D A3D
A1
A1DA1D
A1D
PS
LVOD
RC1
LVOD
LVOD
LVOD
LVOD
LVOD
RC1
RC1
RC1
RC1
RC1
RC1
N1 a
LVD
RC2
a a a a c d c d c b c c d
LVD
a
RC2
N1b
N1b
RC2
LVD
a c d c d c c d c d c c d a a a a aa a a
RC2
a
N1 b a a a
RC2
LVD
a a a aa c d c d c c cc d d
LVD
a
N1
N1 b b
RC2
a a a a
OS1
RC1
D1D D1D D1D
D1D
D1DD1D
RC2
LVD
a a a a a d c d c c
F1E
OS1
aaa a a a a a a aa a d c c cc d a aa a
LVD
a
RC2
V1
V1
V1
V1 e e e e e e e
V1
V1 e e
D1
V1
V1 e e e e
N1 b
LVD
a
RC2
cde
V1
V1 e e cde
LVD
a
RC2
OS2
OS2
OS2
OS2
OS2
OS2 OS2 OS2 OS2
OS2
OS2
OS2
OS2
D3
D1
D1D1
W1E
W1E e e
OS1
OS1OS1
B1D B1DE
CLEAN LINEN
B107
D1D D1D
D1DD1D
D1DE
D1D
D1D
OS1 N1
b c d e N2 b
V1 e
D1 D1
D3cc d
D2D D2D
D2D D2D a a a a
LVD
a
OS1
OS1
OS1
D1
RC1
PS PS
OS1
LVD
RC1
LVD
RC1
B1
B1
OS1
PS
B1
LV1
OS1
OS1
STORAGE
B105
A1 A1
B1D B1D
A3D
A3D
A3D
A3D
A3D
A3D
SNOEZELEN
B134
X1E
X1E
X1E
X1E
X1E
X1E
X1E
RC1
RC2
LVD
a
N1 b 3 c e c c c c c
A3D A3D
A3D
D1
D1
D1
D1E
B1
B1D B1D
B1DB1D
B1
A3D A3DE
D2D D2D
D2DD2D
D3 D1 D1
V1
N2 e d c
N2
N2 b b
N2 b
V1 e
D3 dD1
D1 c c
N2 N2 b b
N2 N2b b
N2 N2b b
N2 b
N2 b b e d c c
LVD
a a a a a
LVD
a
D1
B1 & B2
N1 b
N1b
RC2
N1 b
REC THERAPY
B133
A3D
A3D
A3D
A3D
LED
F3
F3
F3
LVD
RC1
c d e
D2D D2Da a
RC2
N1 b
RC1
RC1
RC1LVD
LVD
LV1
b
LV1
b
LV1
b
LV1
b
LV1
b
LV1
b
LV1
b
LV1
b
LV1
b
LV1
b
B1 B1E B1 B1 B1
B1 & B2
B1 & B2
EQ-B
B1 & B2
TOILET
B135A
TOILET
B136A
TOILET
B137A
TOILET
B131A
TOILET
B126A
TOILET
B125A
TOILET
B124A
TOILET
B123A
TOILET
B122A
TOILET
B121A
TOILET
B120A
T
LS-B (NEW)
B1 & B2 (NEW)
LVD
a b c c c c c c c c c c b a a a a a a a a aa
LV1
b
LV1
bLV1 b
B1 & B2
3 3 3
RC1
RM. B117
RM. B102
LV1
LV1
LVOD
OS1
PS
OS1 PS
B1 & B2
LS-B
LVD
a
LVD
a
LVDa
LVD
a
LVD
a
LVD
LVD
a a
LVD
a
LVOD
LVD
a
LVD
a
LVD
LVD
a a
LVD
a
PS
DINING & DAY ROOM
B108
OS1
X1E
LVOD
LVD
LVOD
LVD
LVD
PS
12 11 10 8 7 6
L
K
J
H
G
F.1
F
E.1
E
D
C
B
A
5 4 3 2 1
X1EX1E
X1E
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL LIGHTING PLAN -
B WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EL101B
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL LIGHTING PLAN - B WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
GENERAL NOTES:
ELECTRICAL PLAN NOTES:
1 REFER TO DETAIL 1, SHEET 6-E-701 FOR WIRING DIAGRAM OF
ALL TYPICAL ROOM CONTROLLERS WITH SWITCHES,
OCCUPANCY SENSORS AND DAYLIGHT SENSORS.
2 REFER TO DETAIL 2, SHEET 6-E-701 FOR WIRING DIAGRAM OF
TYPICAL OFFICE LIGHTS WITH SWITCHES, OCCUPANCY
SENSORS AND DAYLIGHT SENSORS.
3 REFER TO DETAIL 3, SHEET 6-E-701 FOR WIRING DIAGRAM OF
TYPICAL RESIDENT ROOM LIGHTS WITH SWITCHES.
4 REFER TO DETAIL 5, SHEET 6-E-701 FOR WIRING DIAGRAM OF
NURSE STATION B102 AND ALL EXAM ROOM LIGHTS WITH
SWITCHES.
5 REFER TO DETAIL 6, SHEET 6-E-701 FOR WIRING DIAGRAM OF
CORRIDOR LIGHTS WITH SWITCHES, OCCUPANCY SENSORS
AND DAYLIGHT SENSORS.
6 REFER TO DETAIL 4, SHEET 6-E-702 FOR WIRING DIAGRAM OF
DINING AND DAY ROOM B108 WITH SWITCHES, OCCUPANCY
SENSORS AND DAYLIGHT SENSORS. LOCATE CONTROLLER IN
ADJACENT ACCESSIBLE CEILING.
7 REFER TO DETAIL 1, SHEET 6-E-702 FOR WIRING DIAGRAM OF
DAY ROOM ENTRANCE WITH SWITCHES. LOCATE CONTROLLER
IN ADJACENT ACCESSIBLE CEILING.
8 REFER TO DETAIL 6, SHEET 6-E-702 FOR WIRING DIAGRAM OF
NURSE STATION WITH SWITCHES AND OCCUPANCY SENSORS.
DEDUCT ALTERNATE AND PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
J
J
J
STORAGE
A120
DIETICIAN
A121
LACTATION / PUMP
A122
REPORT ROOM
A119
HOSPICE APRN
A118
ACNS
A117
PHARM D
A124
ASST NURSE MNGR
A116
REC THERAPY OFFICE
A125
EXAM
A126
GEC PHYSICIAN
A129
REC THERAPY
A115
PT / OT
A110
ELEC
A111
CONFERENCE
A130
LEARNER OFFICE
A131
STAIR
A135
BREAK ROOM
A132
TESTING
A134
EXAM
A136
NURSE MED
A137
EXAM, BARIATRIC
A138
FAMILY TLT
A102
ED SUPPLY ROOM
A139
BARIATRIC TLT
A103
RECEPTION
A101
STORAGE
A104
STAFF TOILET
A105
STAFF TOILET
A106
MDS / RESTOR OFFICE
A107
TESTING / INTERN
A108
GEROPSYCH
A109
CORRIDOR A
ACDR1
CORRIDOR A
ACDR3
EXAM
A135
PT/OT STOR
A128
SOCIAL WORK
A123
TOILET, BARIATRIC, SHOWER
A133
IT
A114
+80"
LS-A (NEW)
EQ-A (NEW)
A1 & A2 (NEW)
+48"
+48"
EQ-A-T (NEW)
6-E-401
+48"WP/WR
WP/WR
HAC
A127
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
+60"
A1 & A2
A1 & A2
A1 & A2
A1 & A2
EQ-A
A1 & A2
EQ-A
A1 & A2
A1 & A2
EQ-A
A1 & A2
EQ-A
EQ-A
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
A1 & A2
VESTIBULE
A100
A1
6-E-401
A1 & A2
A1 & A2
A1 & A2
USBUSBUSBUSB
USB USB
USB USB
USB
A1 & A2
A1 & A2
A1 & A2
A1 & A2 19 A1 & A2
A1 & A2
A1 & A2
USB
USB
EXISTING
GENERATOR
NEW GENERATOR
A1 & A2
A1 & A2
A1 & A2
PT-01
A1 & A2
1314 12 11 10 8 7 6 5.1 4.1
U
T
S
R
Q
P
O
N
M
L
9 5
A1 & A2
A1 & A2
A1 & A2
A1 & A2
EMDB (ETR)
S (ETR) B6 (NEW)
MSB (ETR)
ATS (ETR)
ES (NEW)
ATS2
EMDB2 (NEW)
MSB2 (NEW)
MTS2 (NEW)
FACP
(ETR)
F/O
(ETR)
MTS
(ETR)
400/3
A1
REFER TO 6-EP101A FOR NEW
AND EXISTING GENERATORS.
10 8 7 6
U
T
S
R
N W
E S
DRAWING NUMBER
VA PROJECT NUMBER
DATE
PROJECT TITLE
BUILDING NUMBER
PROJECT LOCATION
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
VA FORM 08-6231
Office of Construction and Facilities Management
Dwg.
CONSULTANT INFORMATION
STRUCTURAL /
CIVIL ENGINEER
F
STAND STRUCTURAL ENGINEERING
11827 W. 112TH STREET, SUITE 200
OVERLAND PARK, KS 66210
(913) 214-2169
SHEET TITLE
ARCHITECT
MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
PROJECT PHASE
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
U.S. Department of Veteran Affairs
F
E
D
C
B
A
E
D
C
B
A
FIRE PROTECTION
ENGINEER
POOLE FIRE PROTECTION, INC.
19910 W. 161ST STREET
OLATH, KS 66062
(913) 829-8650
WING A
WING B
WING C
WING D
KS ARCH REG. NO. A-1139, EXP. 12/31/2019
KS ENGR REG. NO. E-2586, EXP. 12/31/2019
RENOVATE A & B WING BLDG 6ELECTRICAL POWER PLAN -
A WING
07/10/2019 BEN ABM
2200 SW GAGE BLVD
TOPEKA, KS 66622
6-EP101A
589-A5-19-116
BID DOCUMENTS
1/8" = 1'-0"1
ELECTRICAL POWER PLAN - A WING
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING
FACILITY THAT MUST REMAIN IN SERVICE 24/7.
2. SEE SHEET 6-GI-102 FOR ADDITIONAL INFORMATION REGARDING
SCHEDULE AND PHASING REQUIREMENTS. SCHEDULE WORK TO
MINIMIZE DISRUPTION OF SERVICES.
3. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER’S
REPRESENTATIVE BEFORE THE START OF WORK.
4. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS BEFORE THE START OF WORK.
5. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH CONTRACTING OFFICER’S REPRESENTATIVE.
GENERAL NOTES:
1/8" = 1'-0"2
ELECTRICAL POWER PLAN - BASEMENT
WING A
BASEMENT
DEDUCT ALTERNATE NOTES:
IF DEDUCT ALTERNATE IS ACCEPTED, OMIT ALL CIRCUITING,
RECEPTACLES, AND OTHER ELECTRICAL DEVICES OUTSIDE OF THE
AREA SHOWN. PROVIDE NEW CIRCUITING AND RECEPTACLES
WITHIN THE AREA SHOWN. TIE NEW CIRCUITS INTO EXISTING
PANELBOARD A1 AND A2. PROVIDE NEW 20A BREAKERS AS
REQUIRED.
A1.
DEDUCT ALTERNATE & PHASING:
ALL PLAN WORK SHOWN ON THIS SHEET IS SUBJECT TO THE
OVERALL PROJECT PHASING SEQUENCE OUTLINED ON
ARCHITECTURAL SHEET 6-GI-102.
IN ADDITION, IF THE DEDUCT ALTERNATE IS ELECTED, ALL PLAN
WORK ON THIS SHEET IS ALSO SUBJECT TO THE REDUCED AREAS
OF WORK AS DEFINED ON ARCHITECTURAL SHEET 6-GI-105.
ELEC…