Renovate A & B Wing Building 6 | Topeka VAMC Project Number: 589A5-18-116

Bid Documents | Specifications - Volume II of III

July 10, 2019

405.842.6100

312 SW 25th Street

Oklahoma City, OK 73109

816.214.8730

11020 King Street

Overland Park, KS 66210

A Service-Disabled Veteran-Owned Small Business spur-design.com

Building 6 Renovate A & B Wing

VA 589-A5-19-116

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

CHALKBOARDS AND MARKERBOARDS

10 11 13 - 1

SECTION 10 11 13

CHALKBOARDS AND MARKERBOARDS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies markerboards.

1.2 RELATED WORK

B. Manufacturer, Color, and Style of Markerboards: Section 09 06 00, SCHEDULE FOR FINISHES.

1.3 QUALITY ASSURANCE

A. Provide boards that are the products of a single manufacturer, who has provided units as specified for a minimum of three (3) years.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

C. Shop Drawings: Identifying all parts by name and material and showing design, construction, installation, anchorage and r elation to adjacent construction.

D. Manufacturer's Literature and Data:

2. Markerboard.

E. Samples:

1. Markerboard writing surface, 152 x 152 mm (6 x 6 inches), each color, and texture mounted on backing.

2. Frame material, 305 mm (6 inch) length.

F. Manufacturer’s qualifications.

1.5 WARRANTY

A. Construction Warranty: Comply with FAR clause 52 .246-21, “Warranty of

Construction”.

1.6 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of thi s specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. American Architectural Manufacturers Association (AAMA):

611-14..................Anodized Architectural Alum inum

2603-13.................Voluntary Specification, Pe rformance

Requirements and Test Procedures for Pigmented

Organic Coatings on Aluminum Extrusions and

Panels

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

CHALKBOARDS AND MARKERBOARDS

10 11 13 - 2

C. American National Standards (ANSI):

Z97.1-09(R2010).........Safety Glazing Materials Us ed in Buildings -

Safety Performance Specifications and Methods of Test

D. ASTM International (ASTM):

B221-14.................Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes

B221M-13................Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes (Metric)

C1048-12................Heat-Treated Flat Glass-Kin d HS, Kind FT Coated and Uncoated Glass

E. Code of Federal Regulation (CFR):

40 CFR 59...............Determination of Volatile M atter Content, Water

Content, Density Volume Solids, and Weight

Solids of Surface Coating

F. Composite Panel Association (CPA):

A208.1-09...............Particleboard

A135.4-12...............Basic Hardboard

G. National Association of Architectural Metal Manu facturers (NAAMM):

AMP 500-06..............Metal Finishes Manual

H. Porcelain Enamel Institute (PEI)

1001-11.................Architectural Porcelain Ena mel

PART 2 - PRODUCTS

2.1 MARKERBOARD

A. Provide markerboard with porcelain enamel writin g surface and chalktray.

B. Provide factory assembled unit complete in one ( 1) piece, without joints whenever possible. When markerboard dimensio ns require delivery in separate sections, prefit components at factory, disassembled for delivery and fit joints at site.

C. Frame: Aluminum.

D. Marker Tray: Same material as frame extend full length of markerboard.

E. Map Rail: Not required.

F. Provide surface such that dry erase markings are removable with felt eraser or dry cloth without ghosting.

G. Provide face fabricated from ferromagnetic mater ial.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

CHALKBOARDS AND MARKERBOARDS

10 11 13 - 3

2.2 ACCESSORIES:

A. Provide each markerboard with an eraser and four (4) different color compatible dry erase markers.

2.3 MATERIALS

A. Writing Surface:

1. Provide markerboard writing surface composed of porcelain enamel fused to nominal 0.378 mm (28 gauge) thick steel. L aminate to a minimum 6 mm (1/4 inch) thick core material with a steel or foil backing sheet.

B. Aluminum:

1. Aluminum frame extrusions to be alloy 6063-T5 or 6063-T6, conform to

ASTM B221M (B221). Minimum 1.5 mm (0.06 inches) thi ck.

2. Provide straight, single lengths wherever possib le.

3. Miter corners to have hairline closure.

D. Glass:

1. Provide tempered glass in accordance with ANSI Z 97.1 and conform to

ASTM C1048, Kind FT (fully tempered), Condition A ( uncoated), Type

I, Class I (clear).

E. Adhesives:

1. Adhesives for Field Application: Mildew-resistan t, nonstaining adhesive for use with specific type of panels, shee ts, or assemblies; and for substrate application; as recom mended in writing by visual display unit manufacturer.

2. Adhesives to have VOC content of 50 g/L or less when calculated according to 40 CFR 59, (EPA Method 24).

2.4 GENERAL FINISH REQUIREMENTS

A. Comply with NAAMM’s AMP 500 Series for Architect ural and Metal Products for recommendations for applying and designating fi nishes.

B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

C. Appearance of Finished Work: Noticeable variatio ns in same piece are unacceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved samples and are assembled or installed to minimize contrast.

2.5 ALUMINUM FINISHES

A. Clear Anodic Finish: AAMA 611, AA-M12C22A31, Cla ss II, 0.010 mm (.39 mil) or thicker.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

CHALKBOARDS AND MARKERBOARDS

10 11 13 - 4

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Install units in accordance with the manufacture r's installation instructions with concealed fasteners.

B. Verify partitions have received blocking and rei nforcement before installation of markerboards.

C. Assemble units in accordance with manufacturer’s written instructions.

D. Grounds Designed to Receive Clips for Snap-On Tr im: Continuous and secured 305 mm (12 inches) on center.

E. Miter trim at corners, conceal fasteners. Modify trim as required to conform to surrounding construction details.

3.2 CLEANING

A. Clean in accordance with manufacturers’ written instructions.

B. Touch up factory-applied finishes to restore dam aged or soiled areas.

- - - E N D - - -

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 1

SECTION 10 14 00

SIGNAGE

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies interior signage for room numbers, directional signs exterior signage, code required signs and tem porary signs.

B. This section specifies exterior signage.

1.2 RELATED WORK

A. Electrical Work: Division 26, ELECTRICAL.

B. Lighted EXIT signs for egress purposes are speci fied under Division 26, ELECTRICAL.

C. Color and Finish of Interior Signs: Section 09 0 6 00, SCHEDULE FOR

FINISHES.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Provide signage t hat is the product of one manufacturer, who has provided signage as speci fied for a minimum of three (3) years. Submit manufacturer’s qualifica tions.

B. Installer’s Qualifications: Minimum three (3) ye ars’ experience in the installation of signage of the type as specified in this Section.

Submit installer’s qualifications.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 00, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

B. Interior Sign Samples: Sign panels and frames, w ith letters and symbols, for each sign type.

1. Sign Panel, 203 x 254 mm (8 x 10 inches), with l etters.

2. Color samples of each color, 152 x 152 mm (6 x 6 inches. Show anticipated range of color and texture.

3. Sample of typeface, arrow and symbols in a typic al full size layout.

C. Exterior Sign Samples: 152 x 152 mm (6 x 6 inche s) samples of each color and material.

D. Manufacturer's Literature:

1. Showing the methods and procedures proposed for the anchorage of the signage system to each surface type.

2. Manufacturer’s printed specifications and mainte nance instructions.

E. Sign Location Plan, showing location, type and t otal number of signs required.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 2

F. Shop Drawings: Scaled for manufacture and fabric ation of sign types.

Identify materials, show joints, welds, anchorage, accessory items, mounting and finishes.

G. Full size layout patterns for dimensional letter s.

H. Manufacturer’s qualifications.

I. Installer’s qualifications.

1.5 DELIVERY AND STORAGE

A. Deliver materials to job in manufacturer's origi nal sealed containers with brand name marked thereon. Protect materials f rom damage.

B. Package to prevent damage or deterioration durin g shipment, handling, storage and installation. Maintain protective cover ing in place and in good repair until removal is necessary.

C. Deliver signs only when the site and mounting se rvices are ready for installation work to proceed.

D. Store products in dry condition inside enclosed facilities.

1.6 WARRANTY

A. Construction Warranty: Comply with FAR clause 52 .246-21, “Warranty of

Construction”.

1.7 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of thi s specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. American Architectural Manufacturers Association (AAMA):

611-14..................Anodized Architectural Alum inum

2603-13.................Voluntary Specification, Pe rformance

Requirements and Test Procedures for Pigmented

Organic Coatings on Aluminum Extrusions and

Panels

C. American National Standards Institute (ANSI):

A117.1-09...............Accessible and Usable Build ings and Facilities

D. ASTM International (ASTM):

A36/A36M-14.............Carbon Structural Steel

A240/A240M-15...........Chromium and Chromium-Nicke l Stainless Steel

Plate, Sheet, and Strip for Pressure Vessels and for General Applications

A666-10.................Annealed or Cold-Worked Aus tenitic Stainless

Steel Sheet, Strip, Plate and Flat Bar

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 3

A1011/A1011M-14.........Steel, Sheet and Strip, Hot -Rolled, Carbon, Structural, High-Strength Low-Alloy, High-

Strength Low-Alloy with Improved Formability, and Ultra-High Strength

B36/B36M-13.............Brass Plate, Sheet, Strip, and Rolled Bar

B152/B152M-13...........Copper Sheet, Strip, Plate, and Rolled Bar

B209-14.................Aluminum and Aluminum-Alloy Sheet and Plate

B209M-14................Aluminum and Aluminum-Alloy Sheet and Plate

(Metric)

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)

C1036-11(R2012).........Flat Glass

C1048-12................Heat-Treated Flat Glass-Kin d HS, Kind FT Coated and Uncoated Glass

C1349-10................Architectural Flat Glass Cl ad Polycarbonate

D1003-13................Test Method for Haze and Lu minous Transmittance of Transparent Plastics

D4802-10................Poly(Methyl Methacrylate) A crylic Plastic Sheet

E. Code of Federal Regulation (CFR):

40 CFR 59...............Determination of Volatile M atter Content, Water

Content, Density Volume Solids, and Weight

Solids of Surface Coating

F. Federal Specifications (Fed Spec):

MIL-PRF-8184F...........Plastic Sheet, Acrylic, Mod ified.

MIL-P-46144C............Plastic Sheet, Polycarbonat e

G. National Fire Protection Association (NFPA):

70-14...................National Electrical Code

PART 2 - PRODUCTS

2.1 SIGNAGE GENERAL

A. Provide signs of type, size and design shown on the construction documents.

B. Provide signs complete with lettering, framing a nd related components for a complete installation.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 4

C. Provide graphics items as completed units produc ed by a single manufacturer, including necessary mounting accessor ies, fittings and fastenings.

D. Do not scale construction documents for dimensio ns. Verify dimensions and coordinate with field conditions. Notify Contra cting Officer

Representative (COR) of discrepancies or changes ne eded to satisfy the requirements of the construction documents.

2.2 INTERIOR SIGN MATERIALS

A. Aluminum:

1. Sheet and Plate: ASTM B209M (B209).

2. Extrusions and Tubing: ASTM B221M (B221).

B. Cast Acrylic Sheet: MIL-PRF-8184F; Type II, clas s 1, Water white non-glare optically clear. Matt finish water white clea r acrylic shall not be acceptable.

C. Polycarbonate: MIL-P-46144C; Type I, class 1.

D. Vinyl: Premium grade 0.1 mm (0.004 inch) thick m achine cut, having a pressure sensitive adhesive and integral colors.

E. Adhesives:

1. Adhesives for Field Application: Mildew-resistan t, nonstaining adhesive for use with specific type of panels, shee ts, or assemblies; and for substrate application; as recom mended in writing by signage manufacturer.

2. Adhesives to have VOC content of 50 g/L or less when calculated according to 40 CFR 59, (EPA Method 24).

F. Typography: Comply with VA Signage Design Guide.

1. Type Style: Helvetica Medium and Helvetica Mediu m Condensed. Initial caps or all caps, as indicated in Sign Message Sche dule.

2. Arrow: Comply with graphic standards in construc tion documents.

3. Letter spacing: Comply with graphic standards in construction documents.

4. Letter spacing: Comply with graphic standards in construction documents.

5. Provide text, arrows, and symbols in size, color s, typefaces and letter spacing shown in construction documents. Tex t shall be a true, clean, accurate reproduction of typeface(s). Text shown in construction documents is for layout purposes only; final text for signs is listed in Sign Message Schedule.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 5

2.3 EXTERIOR SIGN MATERIALS

A. Aluminum Sheet and Plate: ASTM B209M (B209).

B. Aluminum Extrusions: ASTM B221M (B221).

C. Brass Sheet (Yellow Brass): ASTM B36/B36M.

D. Bronze Plate: ASTM B36/B36M.

E. Copper Sheet: ASTM B152/B152M.

F. Steel Products: Structural steel products that c onform to

ASTM A36/A36M. Sheet and strip steel products that conform to

ASTM A1011/A1011M.

G. Stainless Steel Sheet: ASTM A240/A240M, stretche r leveled standard of flatness.

H. Acrylic Sheet: ASTM D4802; category as standard with manufacturer for each sign. Provide type UVF.

I. Fiberglass Sheet: Multiple laminations of glass fiber reinforced polyester resin with UV light stabilized, colorfast , nonfading, weather and stain resistant, colored polyester gel coat wit h manufacturer’s standard finish.

J. Polycarbonate Sheet: ASTM C1349, Appendix X1, Ty pe II (coated, mar resistant, UV stabilized polycarbonate) with coatin g on both sides.

K. Finish:

1. Aluminum Finishes:

a. Clear Anodic Finish: AAMA 611.

2. Metallic Coated Steel Finish:

a. Baked Enamel or Powder Coat Finish: After cleani ng and pretreating, apply manufacturer’s standard two (2) coat baked-on finish consisting of prime coat and thermosetting t opcoat to a minimum dry film thickness of 0.05 mm (2 mils).

2.4 INTERIOR SIGN TYPES

A. Conform to the VA Signage Design Guide.

B. Provide sliding rail component system.

C. Component System Signs:

1. Provide interior sign system as follows:

a. Interchangeable system that allows for changes o f graphic components of the installed sign, without changing sign in its entirety.

b. Provide sign system comprised of following prima ry components:

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 6

1) Rail Back: Horizontal rails, spaced to allow for uniform, modular sizing of sign types.

2) Rail Insert: Mount to back of Copy Panels to all ow for attachment to Rail Back.

3) Copy Panels: Fabricate of acrylic materials to a llow for different graphic needs.

4) End Caps: Interlock to Rail Back to enclose and secure changeable Copy Panels.

5) Joiners and Accent Joiners: To connect separate Rail Backs together.

6) Top Accent Bars: To provide decorative trim cap that encloses the top of sign.

c. Provide rail back, rail insert and end caps in a nodized extruded aluminum.

d. Provide signs in system that are convertible in the field to allow for enlargement from one (1) size to another in height and width through use of joiners or accent joiners, whi ch connect rail back panels together blindly, providing a butt joint between copy panels. Connect accent joiners to rail backs w ith a visible

3 mm (1/8") horizontal rib, flush to the adjacent c opy insert surfaces.

e. Provide sign configurations as indicated on cons truction documents that vary in width from 228 mm (9 inches) to 2032 mm

(80 inches), and have height dimensions of 50 mm (2 inches), 76 mm (3 inches), 152 mm (6 inches), 228 mm (9 inches) and 305 mm

(12 inches). Height that can be increased beyond 30 5 mm (12 inches), by repeating height module in full or in p art.

2. Provide rail back functions as internal structur al member of sign.

Fabricate of 6063T5-extruded aluminum,anodized blac k.

a. Fabricate to accept an extruded aluminum or plas tic insert on either side, depending upon sign type.

b. Provide components that are convertible in field to allow for connection to other rail back panels.

c. Provide mounting devices including wall mounting for screw-on applications, wall mounting with pressure sensitive tape, freestanding mount, ceiling mount and other mountin g devices as needed.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 7

3. Provide rail insert functions as mounting device for copy panels on to the rail back. The rail insert mounts to the bac k of the copy panel with adhesive suitable for attaching particul ar copy insert material.

a. Provide copy panels that slide or snap into the horizontal rail back.

4. Provide copy panels that accept various forms of copy and graphics, and attach to the rail back with the rail insert. P rovide copy panels fabricated of acrylic.

a. Provide copy panels that are interchangeable by sliding horizontally from either side of sign, and to other signs in system of equal or greater width or height.

b. Provide materials that are cleanable without use of special chemicals or cleaning solutions.

c. Copy Panel Materials.

1) Changeable Paper/ Insert Holder: Extruded insert holder with integral rail insert for connection with structural back panel in 6063T5 aluminum with a black anodized finish.

a) Inserts into holder are paper with a clear 0.76 mm

(.030 inches) textured cover.

b) Background Color: Painted, acrylic lacquer.

2) Acrylic - 2 mm (.080 inches) non-glare acrylic.

a) Pressure bonded to extruded rail insert using ad hesive.

b) Background Color: Painted in acrylic lacquer or acrylic enamel.

5. End Caps: Extruded using 6063T5 aluminum with a black anodized finish. End caps interlock with rail back with clip s to form an integral unit, enclosing and securing the changeabl e copy panels, without requiring tools for assembly.

a. Interchangeable to each end of sign and to other signs in signage system of equal height.

b. Provide mechanical fasteners that can be added t o the end caps that will secure it to rail back to make sign tampe r resistant.

6. Joiners: Extruded using 6063T5 aluminum with a b lack anodized finish. Rail joiners connect rail backs together bl indly, providing a butt joint between copy inserts.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 8

7. Accent Joiners: Extruded using 6063T5 aluminum w ith a mirror polished finish. Connect joiner and rail backs toge ther with a visible 3 mm (.125 inches) horizontal rib, flush to the adjacent copy panel surfaces.

8. Top Accent Rail: Extruded rail using 6063T5 alum inum with a mirror polished finish that provides a 3.2 mm (.125 inches ) high decorative trim cap. Cap butts flush to adjacent copy panel an d encloses top of rail back and copy panel.

9. Typography:

a. Vinyl First Surface Copy (non-tactile): Applied vinyl copy.

b. Subsurface Copy Inserts: Textured 1 mm (.030 inc hes) clear polycarbonate face with subsurface applied vinyl co py.

1) Spray face back with paint and laminated to extr uded aluminum carrier insert.

c. Integral Tactile Copy Inserts: Phenolic photopol ymer etched with

2.3 mm (.0937 inches) raised copy.

d. Silk-screened First Surface Copy (non-tactile): Injection molded or extruded ABS plastic insert with first surface a pplied enamel silk-screened copy.

D. Tactile Sign:

1. Tactile sign made from a material that provides for letters, numbers and Braille to be integral with sign. Photopolymer etched metal, sandblasted phenolic or embossed material. Do not a pply letters, numbers and Braille with adhesive.

2. Numbers, letters and Braille to be raised 0.8 mm (1/32 inches) from the background surface. The draft of the letters, n umbers and

Braille to be tapered, vertical and clean.

3. Braille Dots: Conform with ANSI A117.1 for Brail le position and layout; (a) Dot base diameter: 1.5 mm (.059 inches) (b) Inter-dot spacing: 2.3 mm (.090 inches) (c) Horizontal separa tion between cells: 6.0 mm (.241 inches) (d) Vertical separation between cells:

10.0 mm (.395 inches)

4. Paint assembly specified color. After painting, apply white or other specified color to surface of the numbers and lette rs. Apply protective clear coat sealant to entire sign.

5. Finish: Eggshell, 11 to 19 degree on a 60 degree glossmeter.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 9

E. Provide cork or felt on bottom or mounting brack et when sign is mounted on counter or desk.

F. For ceiling mounted signs, provide mounting hard ware on the sign that allows for sign disconnection, removal, reinstallat ion, and reconnection.

G. Dimensional Letters:

1. Provide dimensional letters that are mill or las er cut acrylic in size and thickness indicated in construction docume nts.

2. Provide draft of letters perpendicular to letter s face.

3. Fabricate letters with square corners, such as w here a letter stem and bar intersect.

4. Paint letters with acrylic polyurethane.

H. Specialty Signs:

1. Small Freestanding Stanchion Sign: 57 mm (2.25 i nches) polished aluminum tube mounted to weighted 356 mm (14 inches ) diameter polished aluminum base. Sign bracket to hold a 6 mm (.25 inches)copy panel.

2. Freestanding Informational Sign: 57 mm (2.25 inc hes) polished aluminum tube vertical support mounted to a weighte d 356 mm

(14 inches) diameter 57 mm (2.25 inches) polished a luminum base.

Provide rail back mechanically connected to vertica l supports with copy panel attached to front and back.

3. Freestanding Informational Signs for Changeable Messages: 57 mm

(2.25 inches) polished aluminum tube vertical suppo rt mounted to a weighted 365 mm (14 inches) 57 mm (2.25 inches) pol ished aluminum base. Provide rail back mechanically connected to v ertical supports with hinged locking glass door. Provide interior su rface with grooved felt covered changeable letter board or vin yl impregnated tackboard.

4. Card or Paper Holder: Extruded aluminum clip ano dized black containing rollers to pinch and release paper.

a. End caps are black plastic.

5. Patient Information Holder: Provide chart, file, or binder holder constructed of 18 gauge formed. Galvanized steel or aluminum painted in specified color in Section 09 06 00, SCHEDULE FO R FINISHES.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 10

a. Provide polished aluminum connecting rods and bu ttons. Provide button covers for mounting screws that permanently attach and securely conceal screws.

I. Temporary Interior Signs:

1. Fabricated from 50 kg (110 pound) matte finished white paper cut to

101 mm (4 inch) wide by 305 mm (12 inch) long.

a. Punched 3.2 mm (.125 inch) hole with edge of hol e spaced 13 mm

(.5 inch) in from edge and centered on 101 mm (4 in ch) side.

b. Reinforce hole on both sides with suitable mater ial that prevents tie from pulling through hole.

c. Ties: Steel wire 0.3 mm (0.120 inch) thick attac hed to tag with twist leaving 152 mm (6 inch) long free ends.

2. Mark architectural room number on sign, with bro ad felt marker in clearly legible numbers or letters that identify ro om, corridor or space as shown on construction documents.

3. Install temporary signs to rooms that have a roo m, corridor or space number. Attach to door frame, door knob or door pul l.

a. Doors that do not require signs are: corridor do ors in corridor with same number, folding doors or partitions, toil et doors, bathroom doors within and between rooms, closet doo rs within rooms, communicating doors in partitions between ro oms with corridor entrance doors.

b. Replace and missing, damaged or illegible signs.

2.5 FABRICATION

A. Design interior signage components to allow for expansion and contraction for a minimum material temperature rang e of 38 degrees C

(100 degrees F), without causing buckling, excessiv e opening of joints or over stressing of adhesives, welds and fasteners .

B. Form work to required shapes and sizes, with tru e curve lines and angles. Provide necessary rebates, lugs and bracket s for assembly of units. Provide concealed fasteners wherever possibl e.

C. Shop fabricate so far as practicable. Fasten joi nts flush to conceal reinforcement, or weld joints, where thickness or s ection permits.

D. Level and assemble contract surfaces of connecte d members so joints will be tight and practically unnoticeable, without applying filling compound.

E. Signs: Fabricate with fine, even texture to be f lat and sound.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 11

1. Maintain lines and miters sharp, arises unbroken , profiles accurate and ornament true to pattern.

2. Plane surfaces to be smooth, flat and without oi l-canning, free of rack and twist.

3. Maximum variation from plane of surface plus or minus 0.3 mm (0.015 inches). Restore texture to filed or cut areas.

F. Finish extruded members to be free from extrusio n marks. Fabricate square turns, sharp corners, and true curves.

G. Finish hollow signs with matching material on al l faces, tops, bottoms and ends. Mitere edge joints to give appearance of solid material.

H. Do not manufacture signs until final sign messag e schedule and location review has been completed by the COR and forwarded to contractor.

I. Drill holes for bolts and screws. Mill smooth ex posed ends and edges with corners slightly rounded.

J. Form joints exposed to weather to exclude water.

K. Movable Parts, Including Hardware: Cleaned and a djusted to operate as designed without binding or deformation of members. Center doors and covers in opening or frame.

1. Align contact surfaces fit tight and even withou t forcing or warping components.

L. Pre-assemble items in shop to minimize field spl icing and assembly.

Disassemble units only as necessary for shipping an d handling limitations. Clearly mark units for re-assembly and coordinated installation.

M. Prime painted surfaces as required. Apply finish coating of paint for complete coverage with no light or thin application s allowing substrate or primer to show.

1. Finish surface smooth, free of scratches, gouges , drips, bubbles, thickness variations, foreign matter and other impe rfections.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Locate signs as shown on the Sign Location Plans .

B. Conform to the VA Signage Design Guide for insta llation requirements.

C. At each sign location there are no utility lines behind each sign location that will be affected by installation of s igns.

1. Correct and repair damage done to utilities duri ng installation of signs at no additional cost to Government.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

SIGNAGE

10 14 00 - 12

D. Provide inserts and anchoring devices which must be set in concrete or other material for installation of signs. Submit se tting drawings, templates, instructions and directions for installa tion of anchorage devices, which may involve other trades.

E. Refer to Sign Message Schedule for mounting meth od. Mount signs in proper alignment, level and plumb according to the Sign Location Plan and the dimensions given on elevation and Sign Loca tion Plans. When exact position, angle, height or location is not cl ear, contact COR for resolution.

F. When signs are installed on glass, provide blank glass back up to be placed on opposite side of glass exactly behind sig n being installed.

Provide blank glass back that is the same size as s ign being installed.

G. Touch up exposed fasteners and connecting hardwa re to match color and finish of surrounding surface.

H. At completion of sign installation, clean expose d sign surfaces. Clean and repair adjoining or adjacent surfaces that beca me soiled or damaged as a result of installation of signs.

- - - END - - -

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

05-01-15

CUBICLE CURTAIN TRACKS

10 21 23 - 1

SECTION 10 21 23

CUBICLE CURTAIN TRACKS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies cubicle curtain track (C. C.T.) and shower curtain tracks.

1.2 RELATED WORK

A. Steel shapes for suspending track assembly: Sect ion 05 50 00, METAL

FABRICATIONS.

B. Acoustical ceiling tile and suspension systems S ection 09 51 00, ACOUSTICAL CEILINGS.

1.3 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Samples:

1. 305 mm (12 inch) long piece of cubicle curtain t rack with carrier access and end stop.

2. Clip anchor for fastening track to grid system o f acoustical

3. Curtain carrier for attaching curtain to track.

C. Shop Drawings: Showing layout of tracks and meth od of anchorage.

D. Manufacturer's Literature and Data:

1. Cubicle curtain track.

1.4 DELIVERY, STORAGE AND HANDLING

A. Deliver material in original package marked to i dentify the contents, brand name, and the name of the manufacturer or sup plier.

B. Store in dry and protected location. Store so as to not bend or warp the tracks.

C. Do not open packages until contents are needed f or installation, unless verification inspection is required.

1.5 WARRANTY

A. Construction Warranty: Cubicle curtain tracks ar e subject to the terms of the Article “Warranty of Construction,” FAR clau se 52.246-21.

1.6 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of thi s specification to the extent referenced. The publications are referenced in the text by the basic designation only.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

05-01-15

CUBICLE CURTAIN TRACKS

10 21 23 - 2

B. ASTM International (ASTM):

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)

B456-11.................Electrodeposited Coatings f or Copper Plus

Nickel Plus Chromium and Nickel Plus Chromium

C. Aluminum Association (AA):

DAF 45-09...............Designation System for Alum inum Finishes

D. American Architectural Manufacturers Association (AAMA):

2603-13.................Voluntary Specification, Pe rformance

Requirements and Test Procedures for Pigmented

Organic Coatings on Aluminum Extrusions and

Panels

E. The National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500 Series..........Metal Finishes Manual

PART 2 - PRODUCTS

2.1 CUBICLE CURTAIN TRACKS

A. Channel Tracks (Surface Mounted Type): Extruded aluminum, ASTM B221M (B221), alloy 6063, temper T5 or T6, cha nnel shaped, with smooth inside raceway for curtain carriers.

B. Surface mounted hookless curtain track.

C. Curtain Carriers: Nylon carriers, with nylon whe els on metal or nylon axles.

1. Equip each carrier with either stainless steel, chromium plated brass or steel hooks with swivel, or nickel chromiu m plated brass or stainless steel bead chain

2. Hook for bead chain may be the same material and finish as the bead chain or may be chromium plated steel.

3. Provide 2.2 carriers for every 305 mm (1 foot) o f each section of each track length, plus one (1) additional carrier.

D. End Stop Connectors, Ceiling Flanges and Other A ccessories: Fabricate from the same material with the same finish as the tracks or from nylon.

E. Hangers and Fittings: Fabricate from the same ma terial with the same finish as the tracks. Hangers may be round or squar e for channel tracks

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

05-01-15

CUBICLE CURTAIN TRACKS

10 21 23 - 3 and round for tubular tracks. Design fittings to be compatible with design of tracks and to safely transmit the track l oad to the hangers.

F. At end of each section of track, make provision for insertion and removal of carriers. Design to prevent accidental r emoval of carrier.

Provide operating mechanism shall be removable with common tools.

2.2. SHOWER CURTAIN TRACK

A. Provide water/corrosion resistant aluminum surfa ce mounted track system and glider hooks at 10 per meter (3.28 feet).

2.3 FASTENERS

A. Exposed Fasteners, Screws and Bolts: Stainless s teel or chromium/nickel plated brass.

B. Concealed Fasteners, Screws and Bolts: Stainless steel.

C. Metal Clips: Anchor curtain tracks to exposed gr id of lay-in acoustical tile ceilings, with concealed metal (butterfly) typ e or two piece snap locking type ceiling clip of high strength spring s teel.

1. When it is not possible to install the metal cei ling clip, the cubicle curtain track may be screwed to the ceiling grid.

2.4 FINISHES

A. Aluminum: Finish numbers for aluminum specified are in accordance with

AA DAF 45. AA-C22A31 finish, chemically etched medi um matte with clear anodic coating, Class II Architectural, .01 mm (0.4 mils) thick.

B. Chrome/Nickel Plating: Satin or polished finish, ASTM B546, minimum thickness of chromium plate as follows:

1. 0.005 mm (0.2 mil) on copper alloys.

2. 0.01 mm (0.4 mil) on steel.

C. Stainless Steel: No. 4 in accordance with NAAMM AMP 500.

D. Baked Enamel or Powder Coat Finish: AAMA 2603.

2.5 FABRICATION

A. Weld and grind smooth joints of fabricated compo nents.

B. Form tracks and bends of lengths that will produ ce the minimum number of joints. Make track sections up to 4877 mm (16 fe et) without joints.

Form corner bend on a 305 mm (12 inch) radius.

C. Provide steel anchor plates, supports, and ancho rs for securing components to building construction.

D. Form flat surface without distortion.

E. Shop assemble components and package complete wi th anchors and fittings.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

05-01-15

CUBICLE CURTAIN TRACKS

10 21 23 - 4

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install tracks after finish painting and ceiling finishing operations are complete.

B. Install track level and hangers plumb and secure ly anchor to the ceiling to form a rigid installation.

C. Anchor surface mounted curtain tracks directly t o exposed grid of lay-in acoustical tile ceilings with suitable faste ners, spaced approximately 610 mm (24 inches) on center.

D. Anchor surface mounted curtain tracks to concret e, plaster and gypsum board ceilings with a minimum of 3 mm (1/8-inch) di ameter fastenings or concealed clips spaced not more than 914 mm (3 feet ) on center.

E. Fasten end stop caps to prevent them from being forced out by the striking weight of carriers.

F. Remove damaged or defective components and repla ce with new components or repair to the original condition.

G. Install track rigid, plumb, level and true, and securely anchored to the overhead construction.

H. Verify that carrier units operate smoothly and e asily over the full range of travel.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

04-01-19

ACCORDION FOLDING PARTITIONS

10 22 26.13 - 1

SECTION 10 22 26.13

ACCORDION FOLDING PARTITIONS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies electric or manually oper ated, top supported accordion-type folding partitions for wall to wall room division.

1.2 RELATED WORK

A. Steel Supporting Members or Hanger Rods: Section 05 50 00, METAL

FABRICATIONS.

B. Wood Blocking, Rough Bucks, and Headers: Section 06 10 00, ROUGH

CARPENTRY.

C. Wood Trim: Section 06 20 00, FINISH CARPENTRY.

D. Lock Cylinders: Section 08 71 00, DOOR HARDWARE.

E. Color and Texture of Vinyl or Fabric and Color o f Finish on Steel:

Section 09 06 00, SCHEDULE FOR FINISHES.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Obtain products f rom single manufacturer who has provided units as specified for a minimum o f three (3) years.

B. Installers Qualifications: Work is to be perform ed by installer having three (3) years’ experience in work relating to thi s section and approved in writing by partition manufacturer.

1.4 PERFORMANCE REQUIREMENTS

A. The partitions are to provide a complete closure of opening when fully extended and latched.

B. Provide sound rated partitions with a sound tran smission class (STC) of

45 or better when tested in accordance with ASTM E9 0.

C. Provide fabric and lining with flame spread rati ng of 25 or less, fuel contribution rating of 15 or less, and smoke genera tion of 50 or less when tested in accordance with ASTM E84. Complete a ssembly must also meet or surpass the requirements of NFPA 101 and UL 10B.

1.5 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

B. Shop Drawings:

Folding partition, each type, including methods of installation

C. Samples: Panel covering, each different partitio n, 152 mm (6 inch) square.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

04-01-19

ACCORDION FOLDING PARTITIONS

10 22 26.13 - 2

D. Manufacturers' Literature and Data:

1. Folding partition each type.

E. Test Reports:

1. Fire test response characteristics.

2. Sound resistant partitions STC rating.

F. Manufacturer's Certificates:

Certificate certifying that the partition referred to in the test reports conforms to specification requirements, and that the partitions to be provided for the project are the same in all characteristics as that tested in the laboratory.

G. Manufacturer’s qualifications.

H. Installer’s qualifications.

I. Manufacturer’s warranty.

1.6 WARRANTY

A. Construction Warranty: Comply with FAR clause 52 .246-21, “Warranty of

Construction”.

B. Manufacturer Warranty: Manufacturer shall warran ty their accordion folding partitions for a minimum of two (2) years f rom date of installation and final acceptance by the Government . Submit manufacturer warranty.

1.7 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of thi s specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. ASTM International (ASTM):

A1008/A1008M-13.........Steel, sheet, Cold Rolled, Structural, High

Strength Carbon, Low Alloy with Improved

Formability

B221-14.................Aluminum-Alloy Extruded Bar s, Rods, Wire, Shapes, and Tubes

B221M-13................Aluminum-Alloy Extruded Bar s, Rods, Wire, Shapes, and Tubes (Metric)

D751-06(R2011)..........Test Methods for Coated Fab rics

E84-14..................Surface Burning Characteris tics of Building

Materials

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

04-01-19

ACCORDION FOLDING PARTITIONS

10 22 26.13 - 3

E90-09..................Laboratory Measurement of A irborne Sound

Transmission Loss of Building Partitions and

Elements

E413-10.................Rating Sound Insulation

E557-12.................Architectural Design and In stallation Practices for Sound Isolation Between Spaces Separated by

Operable Partitions

C. National Fire Protection Association (NFPA):

70-14...................National Electrical Code

101-15(R2014)...........Life Safety Code

286-15..................Fire Tests for Evaluating C ontribution of Wall and Ceiling Interior Finish to Room Fire Growth

D. Underwriters Laboratories Inc. (UL):

10B-10(R2009)...........Fire Tests of Door Assembli es

PART 2 - PRODUCTS

2.1 MATERIALS

A. Facing Materials:

1. General: Provide facing materials with appropria te backing that comply with indicated fire-test response characteri stics, and are factory attached to accordion folding partitions wi th concealed fasteners. Covering fabrics must conform to the req uirements of ASTM

D751 and NFPA 286.

2. Woven Fabric: Manufacturer’s standard 100 percen t polyolefin woven fabric, from same dye lot, treated to resist stains .

3. Vinyl Coated Fabric: Manufacturer’s standard mil dew resistant, washable, vinyl coated fabric wall covering, comply ing with

CFFA-W-101-D, for Class A.

B. Sheet Steel:

1. ASTM A1008/A1008M, cold rolled, commercial quali ty for partition tracks, lead and jamb posts.

2. The cast or heat analysis report mentioned in th e ASTM is not required.

C. Aluminum Extrusions: ASTM B221M (B221), Alloy 30 03.

D. Sound Insulation: Provide sound insulation as ne cessary to achieve the specified sound transmission class, conforming to A STM E413.

2.2 FABRICATION

A. Track:

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

04-01-19

ACCORDION FOLDING PARTITIONS

10 22 26.13 - 4

1. Minimum 2 mm (0.0747 inch) thick sheet steel.

2. Track depth and shape: In accordance with the ma nufacturer's recommendations for the weight and size of the part ition furnished.

3. Steel track: Baked enamel finish.

4. No floor track will be permitted.

B. Lead and Jamb Posts:

1. 1.78 mm (0.0747 inch) thick sheet steel.

2. Post depth and shape: In accordance with the man ufacturer's recommendations for the weight and size of the part ition furnished.

3. Posts: Baked enamel finish.

C. Suspension System:

1. Four (4) wheels for tandem carriers on lead post s and two (2) wheel for intermediate carriers.

2. Wheels: Steel ball bearing with nylon or steel t read, 25 mm (1 inch) diameter for partitions up to 3962 mm (13 feet) hig h, and 38 mm

(1-1/2 inch) diameter for partitions over 3962 mm ( 13 feet) high.

3. Intermediate carriers: Placed at every other hin ged pair.

D. Frame: Steel, zinc or cadmium coated, with inter ior bracing at top and bottom, and mechanism for producing pantograph acti on.

E. Covering:

1. Attach fabric to the framework with fasteners th at permit easy removal of the cover but prevent sagging or separat ion.

2. Position vertical seams in the bottoms of valley s and reinforce.

3. Provide top and bottom edges of cover fabrics wi th 13 mm (1/2 inch) minimum turned hems.

4. Support vinyl covering over insulating core with outer ply of vinyl material.

F. Seals:

1. Provide seals at floor, ceiling, jambs and abutt ing edges of sound rated partitions.

2. Insulating materials in sound resistant partitio n, perimeter sweep strips and jamb seals are to be the same as those u sed on laboratory tested models that obtained specified acoustical ra ting.

G. Hardware:

1. Provide hardware of the heavy-duty type standard with the manufacturer.

2. Provide pulls and latches for all partitions.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

04-01-19

ACCORDION FOLDING PARTITIONS

10 22 26.13 - 5

3. Provide partitions with keyed locks, privacy lat ches, magnetic contact latches.

2.3 FINISHES

A. Steel (Baked Enamel Finish):

1. Clean exposed metal surfaces free of foreign mat ter, oil and grease, and then give surfaces a prime coat of paint; then apply finish coat of baked-on enamel.

B. Steel (Prime Finish):

1. Provide light colored prime paint after fabricat ion.

2. Paint all contact surfaces of assembled work (ex cept welded contact surfaces and metal concealed in finished work) with an additional shop coat of similar paint.

PART 3 - EXECUTION

3.1 EXISTING CONDITIONS

Verify field dimensions prior to fabrication.

3.2 INSTALLATION

A. General: Comply with ASTM E557 except as otherwi se required by accordion folding partition manufacturer’s written installation instructions. Install accordion folding partitions level and plumb, with tight joints and uniform appearance, and free of deformation and surface and finish irregularities.

B. Install accordion folding partitions and accesso ries after other finishing operations, including painting, have been completed.

C. Recessed Type Installation: Install so that bott om of track is flush with ceiling.

D. Anchorage:

1. Secure ceiling tracks to structural steel suppor ts or other support system as shown on construction documents with 13 m m (1/2 inch) through-bolts or anchor bolts as appropriate.

2. Provide bolts near each end of track and at inte rmediate points not more than 609 mm (2 feet) on centers.

E. Adjustment:

1. Provide shims or other means as required to make partitions close openings fully and completely.

2. Install partitions so that leading edges fit tig ht to jambs or opposing partition leading edge for full height of partition.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

04-01-19

ACCORDION FOLDING PARTITIONS

10 22 26.13 - 6

3. Make all necessary adjustments to assure that ha rdware functions properly.

- - -E N D- - -

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

WALL AND DOOR PROTECTION

10 26 00 - 1

SECTION 10 26 00

WALL AND DOOR PROTECTION

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies wall guards, handrail/wal l guard combinations, corner guards and door/door frame protectors.

1.2 RELATED WORK

A. Structural Steel Corner Guards: Section 05 50 00 , METAL FABRICATIONS.

B. Armor plates and kick plates not specified in th is section: Section 08

71 00, DOOR HARDWARE.

C. Color and texture of aluminum and resilient mate rial: Section 09 06 00, SCHEDULE FOR FINISHES.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Manufacturer with a minimum of three (3) years’ experience in providing items of type specif ied.

1. Obtain wall and door protection from single manu facturer.

B. Installer’s Qualifications: Installers are to ha ve a minimum of three

(3) years’ experience in the installation of units required for this project.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Shop Drawings: Show design and installation deta ils.

C. Manufacturer's Literature and Data:

1. Handrail/Wall Guard Combinations.

2. Wall Guards.

3. Corner Guards.

4. Door/Door Frame Protectors.

D. Test Report: Showing that resilient material com plies with specified fire and safety code requirements.

E. Manufacturer’s qualifications.

F. Installer’s qualifications.

G. Manufacturer’s warranty.

1.5 DELIVERY AND STORAGE

A. Deliver materials to the site in original sealed packages or containers marked with the name and brand, or trademark of the manufacturer.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

WALL AND DOOR PROTECTION

10 26 00 - 2

B. Protect from damage from handling and constructi on operations before, during and after installation.

C. Store in a dry environment of approximately 21 d egrees C (70 degrees F) for at least 48 hours prior to installation.

1.6 WARRANTY

A. Construction Warranty: Comply with FAR clause 52 .246-21 “Warranty of

Construction”.

B. Manufacturer Warranty: Manufacturer shall warran ty their wall and door protection for a minimum of five (5) years from dat e of installation and final acceptance by the Government. Submit manu facturer warranty.

1.7 APPLICABLE PUBLICATIONS

A. Publications listed below form a part of this sp ecification to extent referenced. Publications are referenced in text by basic designation only.

B. ASTM International (ASTM):

A240/A240M-14...........Chromium and Chromium-Nicke l Stainless Steel

Plate, Sheet, and Strip for Pressure Vessels and For General Applications

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)

D256-10.................Impact Resistance of Plasti cs

D635-10.................Rate of Burning and/or Exte nt and Time of

Burning of Self-Supporting Plastics in a

Horizontal Position

E84-14..................Surface Burning Characteris tics of Building

Materials

C. Aluminum Association (AA):

DAF 45-09...............Designation System for Alum inum Finishes

D. American Architectural Manufacturers Association (AAMA):

611-14..................Anodized Architectural Alum inum

E. Code of Federal Regulation (CFR):

40 CFR 59...............Determination of Volatile M atter Content, Water

Content, Density Volume Solids, and Weight

Solids of Surface Coating

F. The National Association of Architectural Metal Manufacturers (NAAMM):

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

WALL AND DOOR PROTECTION

10 26 00 - 3

AMP 500-06..............Metal Finishes Manual

G. National Fire Protection Association (NFPA):

80-13...................Standard for Fire Doors and Windows

H. SAE International (SAE):

J 1545-05(R2014)........Instrumental Color Differen ce Measurement for

Exterior Finishes.

I. Underwriters Laboratories Inc. (UL):

Annual Issue............Building Materials Director y

PART 2 - PRODUCTS

2.1 MATERIALS

A. Stainless Steel: A240/A240M, Type 304.

B. Aluminum Extruded: ASTM B221M (B221), Alloy 6063 , Temper T5 or T6.

Provide aluminum alloy used for colored anodizing c oating as required to produce specified color.

C. Resilient Material:

1. Provide resilient material consisting of high im pact resistant extruded acrylic vinyl, polyvinyl chloride, or inje ction molded thermal plastic conforming to the following:

a. Minimum impact resistance of 960.8 N-m/m (18 ft. -lbs./sq. inch) when tested in accordance with ASTM D256 (Izod impa ct, ft.-lbs.

per inch notched).

b. Class 1 fire rating when tested in accordance wi th ASTM E84, having a maximum flame spread of 25 and a smoke dev eloped rating of 450 or less.

c. Rated self-extinguishing when tested in accordan ce with

ASTM D635.

d. Provide material labeled and tested by Underwrit ers Laboratories or other approved independent testing laboratory.

e. Provide resilient material for protection on fir e rated doors and frames assemblies that is listed by the testing lab oratory performing the tests.

f. Provide resilient material installed on fire rat ed wood/steel door and frame assemblies that have been tested on similar type assemblies. Test results of material tested on any other combination of door and frame assembly are not acce ptable.

Colmery-O’Neil VAMC - Topeka, KS Bid Documents

10-01-15

WALL AND DOOR PROTECTION

10 26 00 - 4

g. Provide integral color with colored components m atched in accordance with SAE J 1545 to within plus or minus 1.0 on the

CIE-LCH scales.

2.2 CORNER GUARDS

A. Resilient, Shock-Absorbing Corner Guards: Surfac e mounted type.

1. Snap-on corner guard formed from resilient mater ial, minimum 1.98 mm

(0.078-inch) thick, free floating on a continuous 1 .52 mm

(0.060-inch) thick extruded aluminum retainer. // R etainer used for flush mounted type to act as a stop for adjacent wa ll finish material.

This is the start of the file's text. The full file is on GovTribe.