PEN WEIGHT LEGEND
LIGHT FIXTURE TO BE REMOVED
EXISTING LIGHT FIXTURE TO REMAIN
NEW LIGHT FIXTURE
LINES ARE TO BE REMOVED.
ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN DARK DASHED
DUPLEX GROUNDED RECEPTACLE TO BE REMOVED
EXISTING DUPLEX GROUNDED RECEPTACLE TO REMAIN
ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN LIGHT SOLID
LINES ARE EXISTING TO REMAIN.
LINES ARE NEW TO BE INSTALLED.
ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN DARK SOLID
NEW DUPLEX GROUNDED RECEPTACLE
SYMBOL DESCRIPTION
SPECIAL OUTLET SCHEDULE
CR
W
E
T
W
H
'FACP'
FSD
FAAP
TS
x-x x-x
J
H
M
D
R
CH
T
K
P
'A'
K PSS
SS SS
S
A
F
A
CT
WP
U
WAP
CS
BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME
RUNS WITH INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE
CIRCUITS (MAXIMUM OF THREE PHASE CONDUCTORS) MAY
BE GROUPED IN A SINGLE CONDUIT. WHERE MULTIPLE
CIRCUITS ARE LOCATED IN THE SAME RACEWAY, JUNCTION
BOX OR ENCLOSURE, NEUTRALS SHALL BE MARKED OR
LABELED TO INDICATE WHICH CIRCUIT THEY ARE
ASSOCIATED WITH. SEE SPECIFICATION SECTION "LOW
VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES"
FOR ADDITIONAL INFORMATION.
WHEN INCREASED CONDUCTOR SIZES ARE SHOWN ON THE
PLANS, THE LARGER CONDUCTOR SIZE SHALL BE USED
THROUGHOUT THE LENGTH OF THE CIRCUIT, INCLUDING
ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST
EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) &
SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED
WITH WIRING AND CONNECTION OF INTERLOCKING AND
CONDUIT RUN W/CONDUCTORS AS INDICATED & GROUND
WIRE SIZED PER N.E.C. 250.122. CONDUIT SIZE AS
"CT" INDICATED ADJACENT TO DEVICE INDICATES DEVICE
MOUNTED ABOVE BACKSPLASH OF COUNTER TOP. VERIFY
EXACT HEIGHT WITH ARCHITECTURAL PLANS AND ELEVATIONS.
REFER TO RELATED ARCHITECTURAL, MECHANICAL, AND
REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE
ALL MOUNTING HEIGHTS TO CENTERLINE OF ITEM UNLESS
OTHERWISE NOTED. VERIFY ALL OUTLET LOCATIONS ON
9.
THE AMERICANS WITH DISABILITIES ACT (ADA).
NEUTRAL AND GROUND.
TO MINIMIZE CUTTING OF BRICK OR BLOCK.
THE JOB PRIOR TO ROUGH-IN.
E.C. SHALL REFER TO MECHANICAL DRAWINGS AND
CONTROLS OF MECHANICAL UNITS AND THERMOSTAT
STRUCTURAL DRAWINGS FOR RELATED INFORMATION.
COORDINATE OUTLET BOX LOCATIONS WITH MASONRY
2.
1.
3.
4.
LOCATIONS.
DRAWINGS.
6.
7.
8.
REQUIRED.
T1.
5.
11.
EACH DATA, TELEPHONE, VIDEO, OR OTHER SYSTEMS
OUTLET REQUIRES 1-1/4"C. WITH PULL ROPE STUBBED 6"
ABOVE NEAREST ACCESSIBLE CEILING UNLESS OTHERWISE
NOTED ON PLANS. CONDUITS STUBBED UP ABOVE CEILINGS
SHALL BE TURNED OUT 90°. PROVIDE INSULATED BUSHINGS
ON ALL CONDUITS. LABEL CONDUIT TO IDENTIFY ITS
INTENDED USE (IE: TELEPHONE, DATA, ETC.).
10.
LOCATE CABLE TRAYS 6" ABOVE CEILING. OFFSET TRAY UP
AND OVER LIGHT FIXTURES AND DUCTWORK (FIELD VERIFY
AND PROVIDE AS REQUIRED). IF PHYSICALLY IMPOSSIBLE
TO RUN CABLE TRAY UP AND OVER, THEN PROVIDE CABLE
SUPPORT HOOKS FROM STRUCTURE ABOVE, SIZED AND
RATED FOR THE INSTALLED CABLES PLUS 25%.
14.
PROVIDE 18" LONG (MIN.) CONDUIT SLEEVES THRU ALL
WALLS WHERE CABLES ARE INDICATED OR REQUIRED TO
PASS THRU WALLS. PROVIDE BUSHINGS ON BOTH ENDS.
SIZE CONDUIT FOR CABLES INSTALLED. AT CABLE TRAYS,
PROVIDE ONE 4" CONDUIT SLEEVE FOR EACH 4" WIDTH OF
CABLE TRAY. MAXIMUMS SHALL BE:
2"C. = 10 CABLES
2 1/2"C. = 20 CABLES
3"C. = 30 CABLES
4"C. = 50 CABLES
13.
LABEL THE FRONT OF EACH RECEPTACLE COVERPLATE
WITH PANEL DESIGNATION AND CIRCUIT NUMBER USING
CLEAR THERMAL TRANSFER (ELECTRONIC DYMO) LABELS
WITH 1/8" HIGH BLACK LETTERS (OR CONTRASTING
COLOR IF PLATES ARE BLACK OR BROWN). LABELS
SHALL BE SUITABLE FOR INDOOR/OUTDOOR USE. LABEL
THE BACK OF EACH LIGHT SWITCH COVERPLATE WITH
PANEL DESIGNATION AND CIRCUIT NUMBER USING A FINE
BLACK PERMANENT MARKER.
JUNCTON BOX OR RECEPTACLE FOR DRINKING FOUNTAINS
SHALL BE LOCATED BEHIND THE EQUIPMENT SKIRT UNLESS
OTHERWISE NOTED. COORDINATE CONNECTION TYPE AND
12.
LOCATION WITH EQUIPMENT PROVIDED.
PROVIDE DIMMER PER THE SPECIFICATIONS. COORDINATE
DIMMER TYPE AND WIRING WITH ASSOCIATED LIGHT FIXTURE
DIMMING REQUIREMENTS (I.E. 3-WIRE, 0-10V, ELECTRONIC
OR MAGNETIC LOW-VOLTAGE, ETC.) OR WITH LIGHTING
CONTROL SYSTEM PROPRIETARY REQUIREMENTS (I.E. LUTRON,
nLIGHT, DALI, ETC.) AS NECESSARY. 3-WIRE DIMMERS SHALL
15.
BE PROVIDED WITH A DEDICATED NEUTRAL FOR EACH
CONTROL ZONE. 0-10V DIMMERS SHALL BE PROVIDED WITH
DIM/ON/OFF CONTROL. COORDINATE PHASE CONTROL OF
LED DRIVERS (I.E. REVERSE PHASE, FORWARD PHASE, ETC.)
WITH LIGHT FIXTURE MANUFACTURER'S RECOMMENDATIONS.
LOW-VOLTAGE CONTROL WIRING IS NOT SHOWN ON PLANS
FOR CLARITY, BUT SHALL BE PROVIDED AS REQUIRED.
F1.
F2.
F3.
FIELD VERIFY LOCATION OF AREA SMOKE DETECTORS AND
HEAT DETECTORS. DO NOT LOCATE WITHIN 36" OF A
HVAC DIFFUSER (SUPPLY OR RETURN), IN A DIRECT AIR
FLOW, WITHIN 36" OF A SPRINKLER HEAD, OR WITHIN
36" OF THE TIP OF A CEILING FAN BLADE. SMOKE
DETECTORS FOR DOOR RELEASE SHALL BE LOCATED ON THE
CENTER LINE OF THE DOOR AND A MAXIMUM OF 5 FEET
FROM THE DOOR. THE MINIMUM DISTANCE FROM THE DOOR
IS THE DEPTH OF THE WALL SECTION ABOVE THE DOOR,
BUT NOT LESS THAN 12".
T2. RUN CABLES CONTINUOUS FROM JACK TO ASSOCIATED
T3.
SYSTEM PATCH PANEL IN CONDUIT, CABLE TRAY, OR
J-HOOKS PER THE PLANS AND SPECIFICATIONS. NUMBER
BESIDE CABLE SYMBOL INDICATES QUANTITY OF CABLES
REQUIRED PER HOME RUN.
PROVIDE QUANTITY AND TYPE OF JACKS PER THE
SPECIFICATIONS AND DETAILS. PROVIDE JACK AND CABLE
LABELING PER THE SPECIFICATIONS.
FIRE ALARM DEVICES SHOWN INDICATE THE MINIMUM
REQUIRED. CONTRACTOR TO PROVIDE ALL ADDITIONAL
DEVICES REQUIRED BY CODE AND AUTHORITY HAVING
JURISDICTION.
INTERLOCK DELAYED EGRESS DEVICE WITH FIRE ALARM
SYSTEM TO ALLOW FREE EGRESS WHEN BUILDING IS IN ALARM
CONDITION.
16. CONNECT POWERED PLUMBING FIXTURE SENSOR AS
REQUIRED. COORDINATE ROUGH-IN AND CONNECTION
REQUIREMENTS WITH FIXTURE MANUFACTURER.
17. EXISTING TELEMETRY AND CELL PHONE REPEATER ANTENNAS
TO REMAIN . PROTECT DEVICE AND CABLING DURING
CONSTRUCTION AND REINSTALL IN EXISTING LOCATIONS.
18. DOOR HOLDER TO BE INTEGRATED INTO DOOR CLOSER.
REFERENCE DOOR HARDWARE SPECIFICATIONS.
N1. THE CONTRACTOR SHALL PROVIDE OUTLET BOXES AND 1"
CONDUIT TO ABOVE THE ACCESSIBLE CEILING FOR ALL NURSE
CALL DEVICE LOCATIONS. ALL NURSE CALL DEVICE LOCATIONS
SHALL BE COORDINATED WITH THE FINAL DRAWINGS FROM THE
NURSE CALL SYSTEM SUPPLIER. COORDINATE BACK BOX SIZES
AND ALL OTHER REQUIREMENTS WITH THE NURSE CALL SYSTEM
SUPPLIER PRIOR TO ROUGH-IN. MOUNTING HEIGHT FOR
EMERGENCY BATH STATIONS SHALL BE PER AIA GUIDELINES.
N2. A GASKET SHALL BE INCLUDED FOR DEVICES LOCATED
ADJACENT TO A SHOWER OR TUB. DEVICE MOUNTING HEIGHT
SHALL BE PER AIA GUIDELINES.
A
A
A
A
A
A
A
GENERAL NOTESFIRE ALARM NOTES
TELECOM NOTES
SYMBOL LIST SYMBOL LIST
NURSE CALL NOTES
DUPLEX GROUNDED RECEPTACLE
EMERGENCY CIRCUIT CEIL./WALL
SWITCH LEGS (#12 UON)
GROUND CONDUCTOR (#12 UON)
CONDUIT RUN PARTIAL CIRCUIT. 2#12
CONDUIT RUN 2#12 & 1#12 GRD.-
CONDUIT RUN 2#12 & 1#12 GRD.-
CONDUIT HOME RUN, 2 CIRCUITS
PHASE CONDUCTORS (#12 UON)
NEUTRAL CONDUCTOR (#12 UON)
CEIL./WALL
EARTH/FLOOR
ELECTRICAL DISTRIBUTION EQUIPMENT
BRANCH CIRCUIT PANEL & PANEL DESIG.
FEEDER DESIGNATION
SPECIAL DEVICE (AS NOTED)
FUSTAT BUSS #SSY
JUNCTION BOX
72" TO TOP
SPECIAL OUTLET (SEE SCHEDULE OR AS NOTED)
GROUND FAULT DUPLEX RECEPTACLE
DOUBLE DUPLEX GROUNDED RECEPTACLE
CLG-MTD DUPLEX GROUNDED RECEPT. CEILING MTD
DF
AFF
NL
a,b,c
SWITCHES (KEYED, PILOT)
SINGLE GROUNDED RECEPTACLE
INDICATES SWITCHING SCHEME
NIGHT LIGHT-WIRE AHEAD OF CONTROLS
ABOVE FINISHED FLOOR
DRINKING FOUNTAIN (SEE GEN NOTE 12)
WEATHERPROOF
SEE GENERAL NOTE 9
EXIT LIGHT (SHADING DENOTES EXIT FACE SIDE)
FIXTURE W/SHADED LAMP(S) ON EMERG. POWER
EMERGENCY BATTERY LIGHT FIXTURE
SWITCHES (1-POLE,2-POLE,3-WAY,4-WAY)
LIGHT FIXTURE & FIXTURE LETTER
46"AFF
46"AFF
CEIL./WALL
CEILING
CEIL./WALL
WALL
SYMBOL
LIGHT FIXTURE & FIXTURE LETTER
LIGHT FIXTURE & FIXTURE LETTER
LIGHT FIXTURE & FIXTURE LETTER
DESCRIPTION
CEILING
CEILING
WALL
CEILING
MOUNTING
UON UNLESS OTHERWISE NOTED
DUPLEX GRD. RECEPT. BOTTOM SWITCHED
CEIL./WALL
18"AFF
FLOOR/WALL
STRIP LIGHT FIXTURE & FIXTURE LETTER
EM LIGHT FIXTURE ON EMERGENCY POWER
18"AFF
18"AFF
18"AFF
18"AFF
CEILINGMASTER/SLAVE FIXTURE WHIP
1/2"C.
3/4"C.
GROUND FAULT DOUBLE DUPLEX RECEPTACLE 18"AFF
& 1#12 GRD. 1/2"C.
CEIL./WALL
CEIL./WALL
CONDUIT HOME RUN, 2 CIRCUITS. 4#12
& 1#12 GRD. 1/2"C.
CEIL./WALLCONDUIT HOME RUN, 1 CIRCUIT. 2#12
& 1#12 GRD. 1/2"C.
CEIL./WALLCONDUIT HOME RUN, 3 CIRCUITS. 6#12
& 1#12 GRD. 1/2"C.
CEIL./WALLCONDUIT HOME RUN, 1 CIRCUIT. 2 #10
& 1 #10 GRD. GEN. NOTE 7 & 8#10
EQUIPMENT - SEE EQUIPMENT
CONNECTION SCHEDULE
CONDUIT SLEEVE (GEN NOTE 13)
CABLE TRAY (GEN NOTE 14)
SYMBOL DESCRIPTION MOUNTING
1 RELAY WALL MTD PIR SENSOR 46"AFF
DUAL TECHNOLOGY SENSOR <1000SF CEILING
THERMOSTAT/TEMPERATURE SENSOR
HANDICAP DOOR RELEASE PUSHBUTTON
DIMMER SWITCH (GEN NOTE 15)
PLUGMOLD SURFACE RACEWAY
46"AFF
WALL
46"AFF
46"AFF
1-VOICE OUTLET & JACK (NOTE T1 & T3)
1-VOICE/1-DATA OUTLET & JACKS
1-DATA OUTLET & JACK (NOTE T1 & T3) 18"AFF
18"AFF
WALL 46"AFFW
18"AFF
VOICE UTP CABLE HOME RUN
DATA UTP CABLE HOME RUN
FIBER OPTIC CABLE HOME RUN (MULTI MODE)
GEN NOTE T2
GEN NOTE T2
GEN NOTE T2
(GEN NOTE T1 & T3)
1-VOICE/2-DATA OUTLETS & JACKS 18"AFF
(GEN NOTE T1 & T3)
SECURITY CARD READER
DOOR POSITION SWITCH
WALL
CLG
CCTV CAMERA - FIXED
CCTV CAMERA - FIXED
46"AFFFIRE ALARM MANUAL STATION
FIRE SPRINKLER TAMPER SWITCH
DUCT SMOKE DETECTOR & FIRE/SMOKE
ELECTROMAGNETIC DOOR HOLDER
FIRE SPRINKLER WATER FLOW SWITCH
FIRE ALARM VISUAL SIGNAL
FIRE ALARM SPEAKER
HEAT DETECTOR (GEN NOTE F1)
DUCT SMOKE DETECTOR (GEN NOTE F2)
PHOTO ELECTRIC AREA SMOKE DETECTOR (GEN NOTE F1)
F.A. RELAY (GEN NOTE F3)
CHIME
SPRINKLER RISER
SPRINKLER RISER
DUCTWORK
CEILING
CEILING
FIRE ALARM CONTROL PANEL WALL
80" TO BOTTOM
COMB. F.A. SPEAKER & VISUAL SIGNAL
80" TO BOTTOM
80" TO BOTTOM
DAMPER (GEN NOTE F2 & F4)
46"AFFHAND-WAVE DOOR OPERATOR
DELAYED EGRESS DEVICE (GEN NOTE F6)
ELECTRIC DOOR STRIKE
DE
E
MAGNETIC DOOR LOCKM
SENSOR TRANSFORMER (GEN NOTE 16)
FIRE ALARM ANNUNCIATOR PANEL
DOOR CONTROL SYSTEM KEYED SWITCH
PUBLIC ADDRESS SPEAKER CEILING
SYMBOL DESCRIPTION
120V. 20A. DUPLEX RECEPTACLE WITH TYPE A AND TYPE C USB
CHARGING PORTS. PROVIDE HUBBELL #USB8300AC5BK OR
APPROVED EQUAL TAMPER RESISTANT RECEPTACLE WITH BLACK
FINISH COLOR AND STAINLESS STEEL COVERPLATE. MOUNT AT 36"
AFF AND ROTATED 90 DEGREES TO BE MOUNTED HORIZONTALLY IN
COUNTERTOP BACK SPLASH.
WIRELESS ACCESS POINT. PROVIDE GREEN CAT-6 DROP WITH 10'-0"
EXCESS CABLE COILED ABOVE THE CEILING. TERMINATE TO 8P8C
CONNECTOR. WAP PROVIDED AND INSTALLED BY GOVERNMENT.
COORDINATE EXACT LOCATION WITH C.O.R.
GEN NOTE 18
VIDEO COAX CABLE HOME RUN GEN NOTE T22
N.C. EMERGENCY BATH STATION (GEN NOTE N1 & N2)
CLG/WALLN.C. VISUAL SIGNAL (GEN NOTE N1)
120V. 20A. DUPLEX RECEPTACLE WITH TYPE A AND TYPE C USB
CHARGING PORTS. PROVIDE HUBBELL #USB8300AC5BK OR
APPROVED EQUAL TAMPER RESISTANT RECEPTACLE WITH BLACK
FINISH COLOR AND STAINLESS STEEL COVERPLATE. MOUNT AT 36"
AFF AND ROTATED 90 DEGREES TO BE MOUNTED HORIZONTALLY IN
COUNTERTOP BACK SPLASH. PROVIDE CHARGETECH #CS8
CHARGING STATION OR APPROVED EQUAL MOUNTED AT OUTLET
LOCATION ON COUNTERTOP. PROVIDE ANTI-THEFT HARDWARE FOR
SECURING THE CHARGING STATION TO THE COUNTERTOP.
LOW VOLTAGE SWITCH 46"AFF
CABLE TV OR VIDEO OUTLET & CONNECTOR 18"AFF
(GEN NOTE T1 & T3)
46"AFFPUSH BUTTON DOOR OPERATOR
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
E-001
ELECTRICAL LEAD SHEET
RENOVATE MAIN LOBBY 589-334
04/03/2018 DLD JLW
ELECTRICAL SHEET INDEX
Sheet
Number Sheet Name
E-001 ELECTRICAL LEAD SHEET
ED101 ELECTRICAL FIRST FLOOR DEMO PLAN
EL101 ELECTRICAL FIRST FLOOR LIGHTING PLAN
EL501 ELECTRICAL LIGHTING DETAILS
EP101 ELECTRICAL FIRST FLOOR POWER PLAN
EP501 ELECTRICAL POWER DETAILS
EY101 ELECTRICAL FIRST FLOOR SYSTEMS PLAN
EY501 ELECTRICAL SYSTEMS DETAILS
M
MMM
D
LIGHTING PLAN NOTES:
1. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS
WITH INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE CIRCUITS
(MAXIMUM OF THREE PHASE CONDUCTORS) MAY BE GROUPED IN A
SINGLE CONDUIT. WHERE MULTIPLE CIRCUITS ARE LOCATED IN
THE SAME RACEWAY, JUNCTION BOX OR ENCLOSURE, NEUTRALS
SHALL BE MARKED OR LABELED TO INDICATE WHICH CIRCUIT THEY
ARE ASSOCIATED WITH. SEE SPECIFICATION SECTION "LOW
VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES" FOR
ADDITIONAL INFORMATION.
2. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS
REQUIRED IN ALL CONDUITS.
3. ALL PENETRATIONS IN THE RATED WALLS AND CEILINGS SHALL BE
SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE
OF FLAMES AND HOT GASSES. THE SEALANT SHALL HAVE A
T-RATING OF ONE HOUR.
4. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE,
COMPUTER, ETC.) IN THE RATED WALLS OR CEILING SHALL BE
CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.
5. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
EXACT LIGHT FIXTURE LOCATIONS. VERIFY ALL DISCREPANCIES
WITH ARCHITECT PRIOR TO ROUGH-IN.
S1 S1 S1
S1 S1 S1S1
S1
S1 S1
LP1-D6.3-277VE
E
E
E
E
EE
S1
S1S1
S1
S1
S1S1S1
S2
S2 S2
S2
S2
S2
S2
S2
S2
S2 S2 S2
S6
S2 S2
S2 S2
V1
V1
X1
S4S4S4S4S4S4S4S4S4
S6 S6 S6 S6 S6
S8S8S8S8S8 S8
S6
S6S6
S6S6
S6
S6
S6
S3S3S3S3S3
LP1-D10-277VN:14
LP1-D10-277VN:14
LP1-D10-277VN:14
LP1-D10-277VN:16
LP1-D10-277VN:18
EX1
L1
L2 L2
L2
L3L3L3L3L3L3L3L3L3
LP1-D10-277VN:14 L2
LP1-D10-277VN:14
L2
E
E
E
E
INFO. DESK
C1E35
PHARM. CARE
SVC.
A119ASILVER TEAM
CHECK IN
A119
ADMISSIONS
SUPERVISOR
E102H
ADMISSIONS
LEAD
E102I
KIOSK
E101
SUPPLY
E102J
HBA
E102F
ROI LEGAL
E102E
HBA
E102D
HBA
E102C
HBA
E102B
PRE-REG
E102A
WORK
E102G
WAITING
PERSONAL
EFFECTS
E102K
HALL
E102
CORR
C1A1
CORR
C1E6
LOBBY
C1E3
MEN TLT
E108
FAMILY TLT
E107
WOMEN TLT
E106
SOILED UTIL.
CHART
112A
CORR.
C1E8
HALL
CORR.
CORR.
TREAT. 1
X1
X1
L2
S4 S4 L3L3
L2
L5 L5 L5 L5 L5 L5
NOT IN SCOPE OF WORK
L6
L6 L7
L7
U2 U2 U2 U2
U2U2U2U2
U2
U2
U2 U2
U1
U1
U2U2
L7
EXISTING TO REMAIN
REMODEL AREA
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
EL101
ELECTRICAL FIRST FLOOR LIGHTING
PLAN
RENOVATE MAIN LOBBY 589-334
04/03/2018 DLD JLW
N
4' 8' 16'
1/8" = 1'-0"
0'
1/8" = 1'-0" A
PARTIAL ELECTRICAL FIRST FLOOR LIGHTING PLAN
N.T.S.
KEY PLAN FIRST FLOOR
N
KEYED NOTES:
L1 CONNECT TO NEAREST EXISTING LIFE SAFETY 277V. LIGHTING
CIRCUIT AND CONTROLS SERVING EXISTING SPACE.
L2 CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS
INDICATED. CIRCUIT SHOWN BASED ON AS BUILT DRAWINGS.
CONTRACTOR TO VERIFY EXISITNG CONDITIONS, AND RE-WORK
EXISTING CONDUIT AND CIRCUITING AS REQUIRED FOR
CONNECTION TO NEW LIGHTS. UPDATE PANEL SCHEDULE
ACCORDINGLY.
L3 LIGHT FIXTURE TO BE INSTALLED IN EXACT LOCATION OF
EXISTING FIXTURE BEING REMOVED. REPAIR EXISTING WALL AS
REQUIRED. CONNECT FIXTURE TO EXISITNG LIGHTING CIRCUIT
AND CONTROLS IN PLACE.
L5 PROVIDE COMBINATION OCCUPANCY SENSOR AND 0-10V DIMMING
SWITCH EQUAL TO WATTSTOPPER PW-311. PROVIDE DIMMING
POWER PACK AT FIXTURE AS REQUIRED FOR MANUAL ON/AUTO
OFF AS WELL AS 0-10V RAISE/LOWER CAPABILITIES.
L6 INTERLOCK OCCUPANCY SENSORS AS REQUIRED.
L7 CONNECT UNDERCABINET LIGHTING TO 120V NORMAL POWER
RECEPTACLE CIRCUIT BELOW.
DOWNLIGHT MOUNTING - GYPBOARD CEILINGLUMINAIRE MOUNTING - LAY-IN CEILINGLUMINAIRE MOUNTING - GYPBOARD CEILING
NO SCALENO SCALENO SCALE
LUMINAIRE SUSPENSION WIRES
(#10 MIN) ATTACHED TO
STRUCTURE
(TYP EA. CORNER)
3 TWIST MINIMUM (TYP)
FIXTURE WHIP FROM
JUNCTION BOX
(6FT. LONG MAX.)
CEILING MAIN BEAM
GYPSUM BOARD (TYP)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE MANUFACTURER'S EARTHQUAKE
CLIP, (4) PER FIXTURE AT CORNERS. ATTACH
WITH SHEET METAL SCREW
CEILING CROSS BEAM
GYPSUM BOARD
CEILING CROSS BEAM
LUMINAIRE.
REFER TO
SCHEDULE
DRYWALL BORDER
LUMINAIRE SUSPENSION WIRES
(#10 MIN) ATTACHED TO
STRUCTURE
(TYP EA. CORNER)
3 TWIST MINIMUM (TYP)
FIXTURE WHIP FROM
JUNCTION BOX
(6FT. LONG MAX.)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE MANUFACTURER'S EARTHQUAKE
CLIP, (4) PER FIXTURE AT CORNERS. ATTACH
WITH SHEET METAL SCREW
ACOUSTICAL CEILING TILE (TYP)
ARCHITECTURAL CEILING
GRID
LUMINAIRE.
REFER TO
SCHEDULE
CEILING HANGER WIRE, TYP.
RECESSED CAN
LUMINAIRE
CEILING MAIN BEAM
GYPSUM BOARD
(TYP)
WIRE TIE OR SCREW BAR
HANGER TO CROSS BEAM TYP.
LUMINAIRE
BAR HANGERS
12GA. HANGER WIRE AT DIAGONAL CORNER
ATTACHED TO STRUCTURE
CEILING CROSS
BEAM
RECESSED CAN LUMINAIRE
CEILING BEAM
LIGHTING FIXTURE SCHEDULE
MANUFACTURER
CATALOG NUMBER SEE NOTES VOLTS
LAMP TYPE
NO. REMARKS
DLWDESCRIPTION LENS\LOUVER\FINISH
CATALOG NUMBER
MANUFACTURERMANUFACTURER
CATALOG NUMBERCATALOG NUMBER
MANUFACTURER
LTR.
FIXT.
(P.E.C.)1 2 3 4
1 GENERAL CONTRACTOR SHALL PROVIDE FIREPROOFING AROUND RECESSED FIXTURES INSTALLED IN FIRE RATED CEILING PER U.L. REQUIREMENTS.
ELECTRICAL CONTRACTOR WILL COORDINATE.
PROVIDE ARROWS AND FACES AS INDICATED ON THE DRAWINGS.
MANUFACTURERS LISTED IN THIS SCHEDULE OR APPROVED BY WRITTEN ADDENDUM WILL BE THE ONLY APPROVED MANUFACTURERS TO BID THE LIGHTING FIXTURES FOR THIS PROJECT. CONTRACTORS AND SUPPLIERS USING PRICING FROM MANUFACTURERS NOT LISTED ON SCHEDULE OR BY
ADDENDUM DO SO AT THEIR OWN RISK.
LIGHT FIXTURE SELECTIONS ARE BASED ON THE MANUFACTURER IN THE LEFT MOST COLUMN AS LISTED IN THE SCHEDULE. FIXTURES APPROVED AS EQUALS IN THIS SCHEDULE OR BY ADDENDUM SHALL BE EQUAL TO THE UNIT SPECIFIED IN THE LEFT MOST COLUMN, IE: SPRING LOADED LATCHES, POST PAINTED FINISH, AND PHOTOMETRICS.
ALL LIGHT FIXTURES SHALL BE SECURED TO THE CEILING FRAMING SYSTEM BY MECHANICAL MEANS (SUCH AS BOLTS, SCREWS, OR RIVETS) OR BY CLIPS
IDENTIFIED FOR USE WITH THE TYPE OF CEILING FRAMING MEMBER AND LIGHT FIXTURE.
LIGHT OUTPUT. LED DRIVERS SHALL HAVE A DISCONNECTING MEANS MEETING THE REQUIREMENTS OF NEC SECTION 410.130(G), EXCEPT FOR THOSE LIGHT FIXTURES SHALL BE PROVIDED WITH 0-10V DIMMING DRIVERS. DRIVERS SHALL BE CAPABLE OF DIMMING TO A MINIMUM OF 10% OF TOTAL
INSTALLED IN CORD-AND-PLUG CONNECTED FIXTURES. WHERE APPLICABLE, WHEN DIMMING SWITCHES ARE NOT PROVIDED AS PART OF THE DESIGN, CONTRACTOR SHALL CAP OFF 0-10V DIMMING WIRES FOR FUTURE EXTENSION BY OWNER.
D EXISTING FIXTURE
TO BE REMOVED
E EXISTING FIXTURE
TO REMAIN
EX1 EXISTING FIXTURE
TO REMAIN
1 FACE/AC EXIT LED
RED W/O BATTERY
S1 CREE
ZR22-32L-40K-10V
OR EQUAL 2X2 LAY-IN 4000K LED
UNV
WHITE 2.0 2.0
3200 LUMEN, 35 WATTS, 80+ CRI6
PROVIDE WITH 0-10V DIMMING
S2 PORTFOLIO
LDRT6B-20-D010-EU6B1020-80
OR EQUAL DOWNLIGHT 4000K LED
UNV
SEMI-SPECULAR .5
2000 LUMEN, 24 WATTS, 80+ CRI6
PROVIDE WITH MEDIUM BEAM SPREAD, SELF FLANGED, SEMI SPECULAR FINISH
S3 LUMIERE LANTERRA
1002-S1-FL-4080-W-WT-36-RS
OR EQUAL WIDE FLOOD LED 4000K
UNV
WHITE
900 LUMENS, 12 WATTS, 80+ CRI
36" STEM, WALL MOUNTED ABOVE EMBLEM AND AIMED BACK DOWNWARD AT EMBLEM.
S4 CORELITE
DWI-WD-4-L40-1C-SU-WA-4-W
OR EQUAL WALL MOUNT LED 4000K
UNV
DIFFUSE/WHITE 4.0
3600 LUMENS, 36 WATTS, 80+ CRI
PROVIDE WITH DUST COVER
S6 LUMENWERX
VIA5RF-HLO-LED-80-750-40-6
OR EQUAL 6FT LINEAR 4000K LED
UNV
WHITE .5 6.0
4500 LUMEN, 39 WATTS, 80+ CRI6
PROVIDE WITH DRYWALL FLUSH TRIM, SINGLE CIRCUIT WITH 0-10V DIMMING
S8 LUMENWERX
VIA5R-ARO2-LED-80-500-40-8
OR EQUAL 8FT LINEAR 4000K LED
UNV
WHITE .5 8.0
4000 LUMENS, 32 WATTS, 80+ CRI6
ASYMMETRIC OPTIC. PROVIDE WITH DRYWALL FLUSH TRIM, SINGLE CIRCUIT WITH 0-10V DIMMING
V1 VISA LIGHTING
CB6456-L40K-L-SNA
OR EQUAL VANITY LIGHT LED 4000K
UNV
SATIN NICKEL 0.33 2.75
2000 LUMENS, 17 WATTS, 80+ CRI
WALL MOUTNED ABOVE VANITY MIRROR.
X1 LITHONIA
EDG-1-RMR
OR EQUAL 1 FACE/AC EXIT LED
UNV
CAST ALUMINUM .167 1.1 .7
RED W/O BATTERY5
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
EL501
ELECTRICAL LIGHTING DETAILS
RENOVATE MAIN LOBBY 589-334
04/03/2018 DLD JLW
File details come from the government source that posted it.