36C25518R0539-0001012.pdf

PDF 5 MB Posted

Attached to
589-334, CO EXPAND PHARMACY AND LOBBY
Solicitation number
36C25518R0539
Issued by

About this file

36C25518R0539 0001 Drawings Renovate Lobby-Vol 2.pdf

View the file

Other files

File Type Posted
36C25518C0223-000.docx DOCX document
36C25518R0539-0005000.docx DOCX document
36C25518R0539-0004001.pdf PDF
36C25518R0539-0004000.docx DOCX document
36C25518R0539-0003001.pdf PDF
36C25518R0539-0003000.docx DOCX document
36C25518R0539-0002002.pdf PDF
36C25518R0539-0002000.docx DOCX document
36C25518R0539-0002001.docx DOCX document
36C25518R0539-0001011.pdf PDF
36C25518R0539-0001003.pdf PDF
36C25518R0539-0001008.pdf PDF
36C25518R0539-0001009.pdf PDF
36C25518R0539-0001001.pdf PDF
36C25518R0539-0001005.pdf PDF
36C25518R0539-0001004.pdf PDF
36C25518R0539-0001014.pdf PDF
36C25518R0539-0001013.pdf PDF
36C25518R0539-0001002.pdf PDF
36C25518R0539-0001010.pdf PDF
36C25518R0539-0001015.pdf PDF
36C25518R0539-0001007.pdf PDF
36C25518R0539-0001006.pdf PDF
36C25518R0539-0001016.pdf PDF
36C25518R0539-0001000.docx DOCX document
36C25518R0539-008.pdf PDF
36C25518R0539-005.pdf PDF
36C25518R0539-001.docx DOCX document
36C25518R0539-003.pdf PDF
36C25518R0539-007.pdf PDF
36C25518R0539-006.pdf PDF
36C25518R0539-004.pdf PDF
36C25518R0539-002.pdf PDF
36C25518R0539-000.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FECFEC

F E

C

F E

C

FEC

2 2 2

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

8 8

EXISTING

FLOOR TILE

TO REMAIN

PROVIDE PLASTIC BARRIER;

PERFORM WORK ON NIGHT

&/OR WEEKENDS -

COORDINATE WITH THE

COR

4 4

17 17 17 17 17

18 18

19 19

A L

IG

N

T

E R

R A

Z Z

O

D E

M O

W

IT

H

R

O N

T F

A C

E

C

L U

M N

EXISTING

WSF

FLOORING

11 11

11 11 11

19 19

GENERAL DEMOLITION NOTES

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING

CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF ANY CONDITIONS

THAT DIFFER FROM INFORMATION INDICATED IN THE DRAWINGS.

B. PROTECT ALL EXISTING BUILDING COMPONENTS TO REMAIN. REPAIR ANY DAMAGED

AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

C. VERIFY EXTENT OF DEMOLITION WORK W/ INFO SHOWN IN THE DRAWINGS AND WORK

THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE THE INTENDED WORK.

D. ALL WORK SHALL COMPLY W/ REQUIRED LOCAL CODES. CONTRACTOR IS RESPONSIBLE

FOR OBTAINING REQUIRED PERMITS & INSPECTIONS FOR ALL WORK ASSOCIATED W/ THE

CONTRACT.

E. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH THE

ORIGINAL STATE OF ADJACENT FINISHES.

F. TYPES OF FLOOR, WALL & CEILING FINISHES INDICATED FOR REMOVAL BY DEMOLITION

NOTES ARE FOR CONTRACTOR'S INFORMATION AND HAVE BEEN OBTAINED FROM

EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY MATERIAL

TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN THE BID.

G. ALL APPLIANCES, FURNITURE AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER. CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

H. MISCELLANEOUS FLOOR PENETRATIONS & DEMO FOR NEW MECHANICAL & ELECTRICAL

WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL,PLUMBING &

ELECTRICAL PLANS.

I. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMO PLANS FOR DEMOLITION,

SALVAGE AND REUSE OF EXISTING ITEMS.

J. PATCH FLOOR AT REMOVED WALLS & CASEWORK. PREPARE FLOOR TO RECEIVE NEW

FLOORING AS REQUIRED.

K. ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE INFILL

RATED AT LEAST 2 HR.

L. REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND RETURN TO THE

OWNER.

M. ALL SIGNAGE TO BE RETURNED TO THE VA IF NOT RELOCATED OR REUSED

N. THERE IS NO KNOWN ASBESTOS CONTAINING MATERIALS (ACM) IN THE REMODEL

AREA. PLEASE NOTIFY ARCHITECT AND COR IF SUSPICIOUS MATERIAL IS UNCOVERED

PRIOR TO REMOVAL.

O. REMOVE DOOR HARDWARE AND RETURN TO OWNER

P. REFERENCE FINISH PLAN FOR LOCATION OF SHEET VINYL. SOME LOCATIONS WILL

REQUIRE TERRAZZO TO BE GROUND DOWN. COORDINATE THIS WITH THE COR PRIOR TO

BEGINNING WORK.

DEMOLITION LEGEND

DOOR & FRAME TO BE REMOVED

WALL TO BE REMOVED

WALL TO REMAIN

DOOR & FRAME TO REMAIN

TERRAZZO TO BE REMOVED -

REF. FINISH PLAN FOR

TRANSITION DETAILS FOR

SELECTIVE TERRAZZO

GRINDING OR FLOORING BUILD

UP

TILE TO BE REMOVED

HANDRAIL TO BE REMOVED

EXISTING HANDRAIL TO REMAIN

STAINLESS STEEL BASE TO BE

REMOVED & STORED

EJ TO BE REMOVED

R.O.I.

E146

TRANSCRIPTION

OFF.

E144

TELEHEALTH

IMAGING

E143

TRAVEL

E140

F.M.S.

ENG.

E138

CORR.

C1F22

ELEVATOR

LOBBY

F.M.S.

ENG.

E137

H. NURSE/

NOD

E.N.T.

EXAM

106PT. TLT.

ISO.

ST. TLT.

SOILED

UTIL.

EXAM

EXAM

RECP.

115TRIAGE

TRIAGE

VERT RM.

VERT RM.

VERT RM.

PT. TLT/

SHR.

EWC

118A

TREAT. 3

TREAT. 4

CORR.

B.H. EXAM

CLEAN

ALCOVE

126A

NOURISH..

109A

CHART

112A

CORR.

CORR.

N. STN./

PHYS. WK.

CORR.

JAN.

OFFICE

B137

LKR.

B144B

ST. TLT.

B143

ST. LNGE.

B144

MED.

ADMIN

E108

F. TLT.

E107

M. TLT.

E106

CORR.

CORR.

C1E14

CORR.

C1E7

CASHIER

WINDOWS

C1E2

MED.

ADMIN.

E102C

MED.

ADMIN.

E102D

MED.

ADMIN.

E102E

MED.

ADMIN.

E102A

MED.

ADMIN.

E102B

MED.

ADMIN.

E102

MED.

ADMIN.

E102G

MED.

ADMIN.

E102F

CORR.

C1E6

LOBBY

C1E3

WAITING

AREA

ALCOVE

113A

ALCOVE

120A

MED.

ADMIN.

E102I

MED.

ADMIN.

E102H

PAT. TLT.

B130

PAT.

INTERVIEW

B133

OFFICE

B138

TELE

HEALTH &

SPEECH

B145

CL.

E105

CL.

E104

CL.

E103

OI&T

CLOSET

B144A

CORR.

C1A1

ADMIN.

B134

CORR

C1E8

CHECK-IN

A119

PAT. REP.

E108B

OFFICE

E147B

LINE OF

CEILING

ABOVE

ST. LNGE./

LKR/

CONF.

EQ. STG.

144 INFO.

MGT. SVC

E139

EYE

SCREENING

E147A

R.O.I.

E145

CASHIER

E142

CORR.

ELEVATOR

LOBBY

C1E9

OEF/OIF

CASE

MGR.

E108A

DETAILS

CLERK

E108C

VEST.

PHARM.

CARE

SVC.

A119A

EXAM

A121

INFO

DESK.

C1E35

WHEELCHAIR

STORAGE

E102J

HALL

CORR.

C1A1

EXISTING TO

REMAIN

REMODEL

AREA

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

AD101

FIRST FLOOR PLAN -

DEMOLITION

RENOVATE MAIN LOBBY 589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR PLAN - DEMOLITION

DEMO SCHEDULE

# DESCRIPTION

1 REMOVE EXISTING WALL OR PORTION OF WALL AS INDICATED - PATCH ADJ. EXIST. WALL AS REQ.

2 REMOVE EXISTING DOOR & FRAME

3 REMOVE EXISTING WINDOW

4 REMOVE EXISTING TILE FLOOR - PREP SUBFLOOR FOR NEW FLOOR COVERING

5 REMOVE EXISTING FLOORING, BASE & GLUE RESIDUE USING MECHANICAL MEANS. PREP SUB-FLOORING FOR NEW FLOOR COVERING

6 REMOVE EXISTING CEILING

7 REMOVE EXISTING MECHANICAL AND ELECTRICAL FIXTURES - REF. MECH. & ELEC. DRAWINGS

8 REMOVE EXISTING PLUMBING FIXTURES & ANY ASSOCIATED PLUMBING (REF. PLUMB.); REPAIR FLOOR, WALLS, & CEILING AS REQ'D TO MAKE LIKE NEW -

MATCH EXISTING FINISH AS REQ'D

9 REMOVE PORTION OF SLOPED SOFFIT AS REQ'D TO MATCH LOCATION OF NEW WALL - PATCH ADJ. CEILING AS REQ'D

10 REPAIR SOFFIT AS NEEDED TO RECEIVE NEW FINISH

11 REMOVE STAINLESS STEEL BASE TRIM & ASSOCIATED PARTS; STORE FOR REUSE IN REMODELED SPACE

12 CAREFULLY REMOVE EXISTING DESK FOR TERAZZO DEMOLITION; STORE DESK TO REINSTALL ON TOP OF NEW FLOORING

13 REMOVE EXISTING BABY CHANGING STATION & STORE FOR REINSTALLATION IN REMODELED SPACE

14 REMOVE PORTION OF HANDRAIL AS NEEDED - RETAIN FOR FUTURE USE ON PROJECT

15 REMOVE EXISTING WALK-OFF MAT

16 REMOVE EXISTING DRINKING FOUNTAIN - REF. MECH.

17 REMOVE EXISTING EJ COVER & EXPANSION MATERIAL

18 REMOVE EXISTING WALL TILE ON REMAINING WALLS

19 REMOVE EXISTING FLOORING, BASE & GLUE RESIDUE BACK TO NEAREST SEAM IN FLOORING. REF FINISH PLAN FOR TRANSITION DETAILS FOR SELECTIVE TERRAZZO GRINDING OR FLOORING BUILD UP - FIELD VERIFY WITH COR PRIOR TO DEMOLITION

20 REMOVE EXISTING TERAZZO FLOOR

21 REMOVE EXISTING EXIT SIGN, FIRE PULL & STROBE; REF. ELEC.

22 RELOCATE EXISTING LIGHT SWITCH AND FIRE PULL; REF. ELEC.

23 REMOVE EXISTING MONITOR AND SAVE FOR REINSTALLATION IN REMODELED SPACE

24 REMOVE EXISTING FURNITURE PANEL WALL TO COMPLETE FLOORING; REINSTALL ONCE FLOORING IS COMPLETE - COORDINATE WORK TIMES W/ COR

PRIOR TO BEGINNING

1" = 80'-0"

KEY PLAN FIRST FLOOR

N

N 4' 8' 16'

1/8" = 1'-0"

0'

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

ST. LNGE./

LKR/

CONF.

108 EQ. STG.

EYE

SCREENING

E147A

INFO.

MGT. SVC

E147C

CASHIER

3' - 5"

NOT IN

SCOPE OF

WORK

7 7

/8 " 7

OPEN TO

ABOVE

R.O.I.

E146

TRANSCRIPTION

OFF.

E144

TELEHEALTH

IMAGING

E143

TRAVEL

E140

ELEVATOR

LOBBY

C1E9

F.M.S.

ENG.

E138

CORR.

C1F22

ELEVATOR

LOBBY

F.M.S.

ENG.

E137

H. NURSE/

NOD

E.N.T.

EXAM

106PT. TLT.

ISO.

ST. TLT.

SOILED

UTIL.

EXAM

EXAM

ALCOVE

103A

RECP.

TRIAGE

TRIAGE

VERT RM.

VERT RM.

VERT RM.

PT. TLT/

SHR.

EWC

118A

ALCOVE

122A

TREAT. 3

TREAT. 4

CORR.

ALCOVE

118B

B.H. EXAM

CLEAN

129B.H. TLT.

ALCOVE

126A

NOURISH..

109A

CHART

112A

CORR.

CORR.

N. STN./

PHYS. WK.

CORR.

CORR.

JAN.

OFFICE

B137

LKR.

B144B

ST. TLT.

B143

ST. LNGE.

B144

MED.

ADMIN

E108

F. TLT.

E107

M. TLT.

E106

CORR.

CORR.

C1E14

CORR.

C1E7

CASHIER

WINDOWS

C1E2

MED.

ADMIN.

E102C

MED.

ADMIN.

E102D

MED.

ADMIN.

E102E

PHARM.

CARE

SVC.

A119A

MED.

ADMIN.

E102A

MED.

ADMIN.

E102B

MED.

ADMIN.

E102

MED.

ADMIN.

E102G

MED.

ADMIN.

E102F

CORR.

C1E6

LOBBY

C1E3

WAITING

AREA

ALCOVE

113A

ALCOVE

120A

VEST.

MED.

ADMIN.

E102I

MED.

ADMIN.

E102H

PAT. TLT.

B130

PAT.

INTERVIEW

B133

OFFICE

B138

CL.

E105

CL.

E104

CL.

E103

OI&T

CLOSET

B144A

CORR.

C1A1

ADMIN.

B134

CORR

C1E8

CORR.

CHECK-IN

A119

PAT. REP.

E108B

OFFICE

E147B

OEF/OIF

CASE

MGR.

E108A

VEST.

DETAILS

CLERK

E108C

INFO

DESK.

C1E35

WHEELCHAIR

STORAGE

E102J

EXISTING TO

REMAIN

REMODEL

AREA

GENERAL DEMOLITION NOTES

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING

CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF ANY CONDITIONS

THAT DIFFER FROM INFORMATION INDICATED IN THE DRAWINGS.

B. PROTECT ALL EXISTING BUILDING COMPONENTS TO REMAIN. REPAIR ANY DAMAGED

AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

C. VERIFY EXTENT OF DEMOLITION WORK W/ INFO SHOWN IN THE DRAWINGS AND WORK

THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE THE INTENDED WORK.

D. ALL WORK SHALL COMPLY W/ REQUIRED LOCAL CODES. CONTRACTOR IS RESPONSIBLE

FOR OBTAINING REQUIRED PERMITS & INSPECTIONS FOR ALL WORK ASSOCIATED W/ THE

CONTRACT.

E. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH THE

ORIGINAL STATE OF ADJACENT FINISHES.

F. TYPES OF FLOOR, WALL & CEILING FINISHES INDICATED FOR REMOVAL BY DEMOLITION

NOTES ARE FOR CONTRACTOR'S INFORMATION AND HAVE BEEN OBTAINED FROM

EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY MATERIAL

TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN THE BID.

G. ALL APPLIANCES, FURNITURE AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER. CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

H. MISCELLANEOUS FLOOR PENETRATIONS & DEMO FOR NEW MECHANICAL & ELECTRICAL

WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL,PLUMBING &

ELECTRICAL PLANS.

I. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMO PLANS FOR DEMOLITION,

SALVAGE AND REUSE OF EXISTING ITEMS.

J. PATCH FLOOR AT REMOVED WALLS & CASEWORK. PREPARE FLOOR TO RECEIVE NEW

FLOORING AS REQUIRED.

K. ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE INFILL

RATED AT LEAST 2 HR.

L. REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND RETURN TO THE

OWNER.

M. ALL SIGNAGE TO BE RETURNED TO THE VA IF NOT RELOCATED OR REUSED

N. THERE IS NO KNOWN ASBESTOS CONTAINING MATERIALS (ACM) IN THE REMODEL

AREA. PLEASE NOTIFY ARCHITECT AND COR IF SUSPICIOUS MATERIAL IS UNCOVERED

PRIOR TO REMOVAL.

O. REMOVE DOOR HARDWARE AND RETURN TO OWNER

P. REFERENCE FINISH PLAN FOR LOCATION OF SHEET VINYL. SOME LOCATIONS WILL

REQUIRE TERRAZZO TO BE GROUND DOWN. COORDINATE THIS WITH THE COR PRIOR TO

BEGINNING WORK.

RCP DEMOLITION LEGEND

WALL TO BE REMOVED

WALL TO REMAIN

LINEAR FIXTURE TO BE

REMOVED

CEILING TILE TO BE

REMOVED

WALL SCONCE TO BE

REMOVED

RECESSED CAN FIXTURE

TO BE REMOVED

SUPPLY VENT TO BE

REMOVED

RETURN VENT TO BE

REMOVED

GYP. CEILING

TO BE REMOVED

GYP. CEILING

TO REMAIN

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

AD102

FIRST FLOOR REFLECTED

CEILING PLAN - DEMOLITION

RENOVATE MAIN LOBBY 589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR REFLECTED CEILING

PLAN - DEMOLITION

N 4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN FIRST FLOOR

N

DEMO SCHEDULE

# DESCRIPTION

1 REMOVE EXISTING WALL OR PORTION OF WALL AS INDICATED - PATCH ADJ. EXIST. WALL AS REQ.

2 REMOVE EXISTING DOOR & FRAME

3 REMOVE EXISTING WINDOW

4 REMOVE EXISTING TILE FLOOR - PREP SUBFLOOR FOR NEW FLOOR COVERING

5 REMOVE EXISTING FLOORING, BASE & GLUE RESIDUE USING MECHANICAL MEANS. PREP SUB-FLOORING FOR NEW FLOOR COVERING

6 REMOVE EXISTING CEILING

7 REMOVE EXISTING MECHANICAL AND ELECTRICAL FIXTURES - REF. MECH. & ELEC. DRAWINGS

8 REMOVE EXISTING PLUMBING FIXTURES & ANY ASSOCIATED PLUMBING (REF. PLUMB.); REPAIR FLOOR, WALLS, & CEILING AS REQ'D TO MAKE LIKE NEW -

MATCH EXISTING FINISH AS REQ'D

9 REMOVE PORTION OF SLOPED SOFFIT AS REQ'D TO MATCH LOCATION OF NEW WALL - PATCH ADJ. CEILING AS REQ'D

10 REPAIR SOFFIT AS NEEDED TO RECEIVE NEW FINISH

11 REMOVE STAINLESS STEEL BASE TRIM & ASSOCIATED PARTS; STORE FOR REUSE IN REMODELED SPACE

12 CAREFULLY REMOVE EXISTING DESK FOR TERAZZO DEMOLITION; STORE DESK TO REINSTALL ON TOP OF NEW FLOORING

13 REMOVE EXISTING BABY CHANGING STATION & STORE FOR REINSTALLATION IN REMODELED SPACE

14 REMOVE PORTION OF HANDRAIL AS NEEDED - RETAIN FOR FUTURE USE ON PROJECT

15 REMOVE EXISTING WALK-OFF MAT

16 REMOVE EXISTING DRINKING FOUNTAIN - REF. MECH.

17 REMOVE EXISTING EJ COVER & EXPANSION MATERIAL

18 REMOVE EXISTING WALL TILE ON REMAINING WALLS

19 REMOVE EXISTING FLOORING, BASE & GLUE RESIDUE BACK TO NEAREST SEAM IN FLOORING. REF FINISH PLAN FOR TRANSITION DETAILS FOR SELECTIVE TERRAZZO GRINDING OR FLOORING BUILD UP - FIELD VERIFY WITH COR PRIOR TO DEMOLITION

20 REMOVE EXISTING TERAZZO FLOOR

21 REMOVE EXISTING EXIT SIGN, FIRE PULL & STROBE; REF. ELEC.

22 RELOCATE EXISTING LIGHT SWITCH AND FIRE PULL; REF. ELEC.

23 REMOVE EXISTING MONITOR AND SAVE FOR REINSTALLATION IN REMODELED SPACE

24 REMOVE EXISTING FURNITURE PANEL WALL TO COMPLETE FLOORING; REINSTALL ONCE FLOORING IS COMPLETE - COORDINATE WORK TIMES W/ COR

PRIOR TO BEGINNING

REF. FLOOR

PLAN FOR

EXACT

DIMENSIONS

EXISTING TO

REMAIN

REMODEL

AREA

HBA

E102F

ROI

LEGAL

E102E

HBA

E102D

HBA

E102C

SUPPLY

E102J

HBA

E102B

PRE-REG

E102A

KIOSK

E101

ADMISSIONS

LEAD

E102I

ADMISSIONS

SUPERVISOR

E102H

WORK

E102G

WAITING

PERSONAL

EFFECTS

E102K

AI401

AI401

AI401

E102

E102K

E102IE102H

E102G

HALL

E102

CORR

C1A1

LOBBY

C1E3

E102F E102AE102BE102CE102DE102E

A10A10A10 A12 A11

LINE OF

CEILING

ABOVE

A10

AS101

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

CORR.

B116

ADMIN.

B134

OFFICE

B138

OFFICE

B137

JAN

LKR.

B144B

ST. LNGE.

B144

MEN TLT

E108

PAT. REP.

E108B

DETAILS

CLERK

E108C

FAMILY

TLT

E107

WOMEN

TLT

E106

CL.

E103

CL.

E104

CL.

E105

TREAT. 4

PT.

TLT/SHR.

CORR.

CORR.

119 TRIAGE

RECEP.

CORR.

112 TRIAGE

SOILED

UTIL.

111CLEAN

VERT RM.

VERT RM.

VERT RM.

B.H. EXAM

B.H. TLT.

CHART

112A

ELEVATOR

LOBBY

ELEVATOR

LOBBY

C1E9

OFFICE

E147B

CORR.

C1E8

TRANSCRIPTION

OFF.

E144

R.O.I E145

VEST.

OI&T

CLOSET

B144A

NOURISH.

109A

CORR.

CORR.

C1E8

PHARM.

CARE

SVC.

A119A

CHECK-IN

A119

N. STN./

PHYS. WK.

EXAM

EXAM

ISO.

E.N.T.

EXAM

H. NURSE

/ NOD

ST. LNGE./

LKR/

CONF.

EYE

SCREENING

E147A

R.O.I E146

INFO.

MGT. SVC

E147C

F.M.S.

ENG.

E138

EQ. STG.

F.M.S.

ENG.

E137

AI401

AI401 6

AI401

AI401

CASHIER

WINDOWS

TRAVEL

TELEHEALTH

IMAGING

CASHIER

CORR

C1E6

PAT.

INTERVIEW.

B133

PAT. TLT.

B130

TREAT. 3

HALL

CORR.

CORR.

CORR.

ST. TLT

B143

CORR.

ENTR.

VEST.

EXAM

AS101

B

AI401 2

AI40112

AI401

REV

AS701

INFO.

DESK

C1E35

AI401

AI401

AI401

AI401

AI401

AI401

AI401

AI401

AI401

AI401

AI401

C1E6

AS101

AS102

HM

FRAME

R E

F S

C H

E D

2"

SCHED.

REF. 2"

AS101

AS101

AS101

2"

SCHED.

REF.

SCHED.

REF. 2"

R E

F S

C H

E D

AS101

2' - 8" TYP. 4' - 3" TYP.

A10

T

CLEAR

(GLS - 3)

75%

FROST

(GLS - 1)

T

T T

AS101

FULL PANE

FADE 75% @

BOTTOM TO

25% @ TOP

(GLS-2)

1' - 9" 4' - 3"

A11

T

CLEAR

(GLS - 3)

75%

FROST

(GLS - 1)

T

T T

AS101

FULL PANE

FADE 75% @

BOTTOM TO

25% @ TOP

(GLS-2)

A12

T

AS101

2' - 8" 4' - 3"

CLEAR

(GLS - 3)

FULL PANE

FADE 75%

@ BOTTOM

TO 25% @

TOP (GLS-2)

75%

FROST

(GLS - 1)

T

T T

A B

R E

F S

C H

E D

SCHED.

REF.

SCHED.

REF.

R E

F S

C H

E D

T

T

SCHED.

REF.

R E

F S

C H

E D

4" X 24"

VISION

PANEL

C

75% FROM

BOTTOM OF

GLASS TO 3'-2";

75% TO 25%

FADE FROM

3'-2" TO TOP OF

GLASS (GLS - 2)

4" 6"

TEMPERED SAFETY

GLASS - REF. SPECS

STOREFRONT LEGEND

= GLASS - REF. SPECS

T

FROSTED GLASS

REF. SPECS & ELEVATION

FOR LOCATION AND TYPE

CAULKING @ EA. SIDE

BOXED HEADER

H.M. FRAME W/ MIN. 3

ANCHORS EA. SIDE -

REF. SCHED.

DOOR PER SCHED.

GYP. BD. & MTL. STUD WALL

PER PART. SCHED.

CAULKING @ EA. SIDE

DOOR PER SCHED.

H.M. FRAME W/ MIN. 3

ANCHORS EA. SIDE -

REF. SCHED.

GYP. BD. & MTL. STUD WALL

PER PART. SCHED.

20 GA. DBL STUDS @

JAMBS, TYP.

U .N

.O

T Y

P

EXISTING CEILING; PATCH

AND REPAIR AS REQ'D -

REF. REFLECTED CLG.

PLAN & FINISH SCHED.

BACKER ROD & SEALANT

ANODIZED ALUM.

STOREFRONT - REF. SPECS

1/2" GLAZING REF. ELEVATION

FOR TYPE & LOCATION; REF.

SPECS.

AI401

AI40120

AI401

AI40123

AI40125

MEN TLT

E108

PAT. REP.

E108B

DETAILS

CLERK

E108C

FAMILY

TLT

E107

WOMEN

TLT

E106

AI401 17

AI401

AI401 24

AI40125

E108

E107

E106

AS701

SIM

SIM

SIM

5' - 0" 3' - 1" 5' - 8" 4' - 9"

1' - 0" 7' - 5" 3' - 1" 3' - 1" 5' - 1"

BACKER ROD & SEALANT

ANODIZED ALUM.

STOREFRONT - REF. SPECS

1/2" GLAZING REF. ELEVATION

FOR TYPE & LOCATION; REF.

SPECS.

GYP. BD.

PAINTED - REF.

FINISH SCHED.

BOXED HEADER

T.O. HEADER

10' - 0"

B.O. HEADER

9' - 0"

PLAN LEGEND

SELF LEVELING

CONCRETE @ RECESSED

SLAB

COUNTER SINK LEDGE

AROUND EXIST. HOLE

EXISTING

CONCRETE SLAB

EXIST. HOLE DIA.

MIN

1"

NEW GROUT OR CONC. FILL

FIRE RETARDANT PLYWD.

POUR-STOP ON BOTTOM OF

SLAB

(2) PINS ANCHORED

TO SIDES OF

EXISTING HOLE AS

REQ'D

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

AS101

FIRST FLOOR PLAN

RENOVATE MAIN LOBBY 589-334

04/03/2018

N 4' 8' 16'

1/8" = 1'-0"

0'

N

PLAN NOTES - FLOOR PLAN

# DESCRIPTION

1 NEW EJ COVERS & RUBBER GASKET - REF. SPECS & SHEET AI101 FOR DETAILS

2 REINSTALL EXISTING DESK ON TOP OF NEW FLOORING

3 MATCH EXISTING WALL AND BASE FINISH

4 OPEN TO ABOVE

5 USE SELF LEVELING CONCRETE TO MAKE WALK-OFF TILE LEVEL W/ ADJACENT

FINISHES

6 PAINT SOFFIT AS CONTINUES IN ENTRY VESTIBULE

7 NEW TOILET PARTITIONS - REF. SPECS

1" = 80'-0"

KEY PLAN FIRST FLOOR

1/8" = 1'-0" A

FIRST FLOOR PLAN

DOOR SCHEDULE

DOOR

NO. SIZE

HDWR

SET

FIRE

RATING

DOOR FRAME DETAILS

REMARKSTYPE MATERIAL GLASS TYPE MATERIAL GLASS HEAD JAMB

C1E6 4'-0" x 7'-0" x 1 3/4" PR 8.0 90 MIN. C HM SAFETY 2 HM - 1/AS101 2/AS101

E102 3'-6" x 7'-0" x 1 3/4" 1.0 A WD - 1 HM - 1/AS101 2/AS101

E102A 4'-0" x 7'-2" x 1 3/4" 2.0 B ALUM SAFETY - GLS-2 - ALUM SAFETY - GLS-1,2,3 4/AS101 REF. STOREFRONT ELEVATION FOR GLASS TYPE & LOCATION; REF. SPECS

E102B 4'-0" x 7'-2" x 1 3/4" 2.0 B ALUM SAFETY - GLS-2 - ALUM SAFETY - GLS-1,2,3 4/AS101 REF. STOREFRONT ELEVATION FOR GLASS TYPE & LOCATION; REF. SPECS

E102C 4'-0" x 7'-2" x 1 3/4" 2.0 B ALUM SAFETY - GLS-2 - ALUM SAFETY - GLS-1,2,3 4/AS101 REF. STOREFRONT ELEVATION FOR GLASS TYPE & LOCATION; REF. SPECS

E102D 4'-0" x 7'-2" x 1 3/4" 2.0 B ALUM SAFETY - GLS-2 - ALUM SAFETY - GLS-1,2,3 4/AS101 REF. STOREFRONT ELEVATION FOR GLASS TYPE & LOCATION; REF. SPECS

E102E 4-0" x 7'-2" x 1 3/4" 2.0 B ALUM SAFETY - GLS-2 - ALUM SAFETY - GLS-1,2,3 3/AS101 REF. STOREFRONT ELEVATION FOR GLASS TYPE & LOCATION; REF. SPECS

E102F 4'-0" x 7'-2" x 1 3/4" 2.0 B ALUM SAFETY - GLS-2 - ALUM SAFETY - GLS-1,2,3 4/AS101 REF. STOREFRONT ELEVATION FOR GLASS TYPE & LOCATION; REF. SPECS

E102G 3'-6" x 7'-0" x 1 3/4" 3.0 90 MIN. A WD - 1 HM - 1/AS101 2/AS101

E102H 3'-6" x 7'-0" x 1 3/4" 4.0 C WD SAFETY 1 HM - 1/AS101 2/AS101

E102I 3'-6" x 7'-0" x 1 3/4" 4.0 C WD SAFETY 1 HM - 1/AS101 2/AS101

E102K 4'-0" x 7'-0" x 1 3/4" 5.0 A WD - 1 HM - 1/AS101 2/AS101

E106 3'-6" x 7'-0" x 1 3/4" 6.0 A WD - 1 HM - 1/AS101 2/AS101

E107 3'-6" x 7'-0" x 1 3/4" 7.0 A WD - 1 HM - 1/AS101 2/AS101

E108 3'-6" x 7'-0" x 1 3/4" 6.0 A WD - 1 HM - 1/AS101 2/AS101

STOREFRONT ELEVATIONS - INTERIOR TYP

1/4" = 1'-0"

1 1/2" = 1'-0"

HM DOOR (HEAD)

1 1/2" = 1'-0"

HM DOOR (JAMB)

1 1/2" = 1'-0"

STORE FRONT @ E102E

1/4" = 1'-0"

B

ENLARGED PLAN - TOILETS

N 2' 4' 8'0'

1/4" = 1'-0" 1 1/2" = 1'-0"

STOREFRONT HEAD TYP.

DOOR TYPE ELEVATIONS

1/4" = 1'-0"

DOOR FRAME ELEVATIONS

1/4" = 1'-0"

3" = 1'-0"

PLUG DETAIL @ EXIST. HOLES IN SLAB

ROI

LEGAL

E102E

HBA

E102F

WORK

E102G

ADMISSIONS

SUPERVISOR

E102H

ADMISSIONS

LEAD

E102I

SUPPLY

E102J

KIOSK

E101

PRE-REG

E102A

HBA

E102B

HBA

E102C

HBA

E102D

WAITING

2' - 3" 10' - 8" 5' - 2" 11' - 1" 2' - 1"

7"

6' - 10" 8' - 10" 4' - 8"

L3A

L3A

L3A

L3A

L3N

L3A

L3N

L3A

L3A L3A

L3A

L3A

L3AR

L3N

L1NL1NL1N

L3N

L3AL3NL1N

L3N

L3N

L3A

L3A

EGHKLMNa

E 1

ACA

ACA

ACA

ACA

ACA

ACA

10.6

ACA

5.6

ACA

ACA

ACA

D

ACA

C

ACA

B

ACA

A

ACA

6.3

PERSONAL

EFFECTS

E102K

LINE OF

CEILING

ABOVE

L3N

2' - 4"

1' - 5" 7' - 4" 7' - 4" 7' - 4" 7' - 4"

1' - 9"

6' - 5" 7' - 4" 6' - 0" 9' - 5" 14' - 10"

/2

/2 "2

/2

/2

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

VEST.

ADMIN.

B134

OFFICE

B138

JAN

OFFICE

B137

LKR.

B144B

CORR.

B116

OI&T

CLOSET

B144A

ST. LNGE.

B144

ST. TLT

B143

PAT. REP.

E108B

DETAILS

CLERK

E108C

CL.

E105

CL.

E104

CL.

E103

MEN TLT

E108

FAMILY

TLT

E107

WOMEN

TLT

E106

TREAT. 4

PT.

TLT/SHR.

TRIAGE

CORR.

CORR.

VERT RM.

VERT RM.

VERT RM.

B.H. TLT.

B.H. EXAM

CLEAN

NOURISH.

109A

CHART

112A

CORR.

RECEP.

TRIAGE

CORR.

SOILED

UTIL.

ELEVATOR

LOBBY

ELEVATOR

LOBBY

C1E9

OFFICE

E147B

CORR.

C1E8

CORR.

C1E8

TRANSCRIPTION

OFF.

E144

R.O.I E145

PHARM.

CARE

SVC.

A119A

CHECK-IN

A119

± 21' - 7" ± 11' - 1" 2' - 4" 11' - 6" 4' - 9" 4' - 2"

1' - 1"

1' - 11" 5' - 6" 4' - 0"

11" 1' - 5"

5' - 3"

3' - 4"

N. STN./

PHYS. WK.

EXAM

EXAM

ISO.

E.N.T.

EXAM

H. NURSE

/ NOD

ST. LNGE./

LKR/

CONF.

EQ. STG.

F.M.S.

ENG.

E137

F.M.S.

ENG.

E138

INFO.

MGT. SVC

E147C

EYE

SCREENING

E147A

R.O.I E146

CORR

C1A1

HALL

E102

CORR

C1E6

LOBBY

C1E3

CORR.

EXAM

TRAVEL

TELEHEALTH

IMAGING

CASHIER

CASHIER

WINDOWS

TREAT. 3

PAT.

INTERVIEW.

B133

PAT. TLT.

B130

HALL

CORR.

CORR.

L3A

L3N L3N

L3AL3A

L3A

L3AL3A

L3A

L3A

L3A

L3A

L3A

L3A L3A

L3A

L3A

L3N

L3A L3A

L3N

L3A L3A L3A L3A

L3A

L3A

L3A

L3A

± 16' - 5"

± 14' - 10"

L3A

INFO.

DESK

C1E35

L3A

1' - 2"

1 1

/4

32' - 6" 8' - 4 1/2"

L3AR

AS102

1' - 10 7/16"

4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"

EXISTING TO

REMAIN

REMODEL

AREA

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

L - LIGHT GAUGE METAL STUDS, 20 ga. (REF. SPECS.)

WALL WIDTHS

0 - 7/8" HAT CHANNEL

1 - 1 5/8" HAT CHANNEL/ STUDS

6 - 6" METAL STUD FRAMING

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL

SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL TILE.

TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT GYP

BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND GA-216.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK - REF STRUCT.

N - NONE

A - ACC0USTICAL

XXXX

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS THAT

EXTEND TO DECK OR HARD CEILING

ABOVE

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED

OTHERWISE. PROVIDE ACCOUSTICAL SEALANT AT TOP

AND BOTTOM OF ALL PENETRATIONS OF WALL WITH

SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

RATED

INDICATES WALL THAT EXTEND 6"

ABOVE CEILING

3 - 3 5/8" METAL STUD FRAMING

R - RATED

HALL

E102

PRE-REG

E102A SUPPLY

E102J

REFERENCE REFLECTED CEILING

PLAN FOR DETAILS AND LOCATIONS

OF ANGLED SOFFITS

REFERENCE REFLECTED CEILING PLAN

FOR FINISH ON NEW SLOPED GYP

CEILING

OPEN TO

BEYOND

REFERENCE REFLECTED CEILING

PLAN FOR NEW CEILING TYPE AND

HEIGHT

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

AS102

FIRST FLOOR PLAN -

DIMENSIONS

RENOVATE MAIN LOBBY 589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR PLAN - DIMENSIONS

N

4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN FIRST FLOOR

N

PLAN NOTES - DIMENSIONS

# DESCRIPTION

1 ALIGN NEW WALL

1/4" = 1'-0"

SECTION

2X2 FIXTURE

CEILING HEIGHT

SYMBOL LEGEND

RECESSED CAN FIXTURE

EX EXISTING CEILING

NOTE: REFERENCE MECHANICAL &

ELECTRICAL DRAWINGS FOR SYMBOLS NOT

SHOWN HERE.

RETURN AIR GRILLE

SUPPLY AIR GRILLE

8' - 0"

EXIT SIGN

PATCH EXISTING CEILING

OCCUPANCY SENSOR

RECESSED LINEAR FIXTURE

COVE FIXTURE

EXHAUST AIR GRILLE

EXISTING ACCESS PANEL

GENERAL NOTES

1. REFERENCE AS702 FOR ADDITIONAL

PAINTED CEILING SURFACES

EXISTING TO

REMAIN

REMODEL

AREA

VARIES REF.

CEILING PLAN

SUSPENDED ACOUST. CLG.

SYSTEM - REF. PLANS

VARIES REF.

CEILING PLAN

VARIES REF.

CEILING PLAN

3 5/8" MTL. STUD FRAMING

@ 16" O.C. MIN. UNLESS

NOTED OTHERWISE

SUSPENDED ACOUST. CLG.

SYSTEM - REF. PLANS

5/8" GYP. BD. BULKHEAD

ON 3 5/8" MTL. STUD

FRAMING @ 16" O.C.

M

IN

VARIES REF.

CEILING PLAN

GYP. BD. ON MTL. STUDS -

REF. PART. SCHED.

GYP. BD. SOFFIT ON

3 5/8" MTL. STUD

FRAMING @ 16" O.C.

SUSPENDED ACOUST. CLG.

SYSTEM - REF. PLANS

WHEN SOFFIT OCCURS AT

MILLWORK VERIFY DEPTH WITH

MILLWORK DETAIL

REF. PLAN

3 5/8" MTL. STUD FRAMING

@ 16" O.C. MIN. UNLESS

NOTED OTHERWISE

VARIES REF.

CEILING PLAN

GYP. BD. TO CONT. UP

TO DECK @ RATED &

SOUND PARTITIONS -

REF. PART. SCHED.

VARIES REF.

CEILING PLAN

SUSPENDED ACOUST. CLG.

SYSTEM - REF. PLANS

VARIES REF.

CEILING PLAN

VARIES REF.

CEILING PLAN

3 5/8" MTL. STUD FRAMING

@ 16" O.C. MIN. UNLESS

NOTED OTHERWISE

SUSPENDED ACOUST. CLG.

SYSTEM - REF. PLANS

5/8" GYP. BD. SOFFIT ON

3 5/8" MTL. STUD

FRAMING @ 16" O.C.

M

IN

REF. PLAN

LIGHT FIXTURE - REF.

ELECTRICAL FOR

LOCATIONS FIXTURE

OCCURS & TYPES

NOT IN

SCOPE OF

WORK

AS701

NEW SLOPED GYP.

BD. CEILING; ADJUST

FIRE SPRINKLER

HEADS AS REQ'D BY

FIRE PROTECTION

ENG.

EXISTING

WINDOW

TO REMAIN

PT-13 PT-13 PT-13 PT-13 PT-13PT-13PT-13PT-13PT-13 PT-13 PT-13 PT-13 PT-13PT-13

ALL BEAMS

TO BE PT-5 PT- 4 PT- 4 PT- 4 PT- 4 PT- 4 PT- 4 PT- 4 PT- 4

1' - 6" 4"

5/8" GYP. BD. ON

3 5/8" MTL STUD,

16"O.C.

PT- 4 PT- 4 PT- 4

NEW SLOPED GYP.

BD. CEILING; ADJUST

FIRE SPRINKLER

HEADS AS REQ'D BY

FIRE PROTECTION

ENG.

WORK

E102G

HBA

E102F

ROI

LEGAL

E102E

HBA

E102D

HBA

E102C

HBA

E102B

PRE-REG

E102A

KIOSK

E101

PERSONAL

EFFECTS

E102K

SUPPLY

E102J

ADMISSIONS

LEAD

E102I

ADMISSIONS

SUPERVISOR

E102H

8' - 0" 8' - 0" 8' - 0"

8' - 0"

8' - 0"

9' - 1"

HALL

E102

EX

AS101

7' - 11"

NEW E.J. COVERS -

REF. AI101 FOR

DTLS.

7' - 11"

EX

IN

F

IL

L

C E

IL

IN

G

CORR.

B116

OFFICE

B138

ADMIN.

B134

JAN

OFFICE

B137

PT.

TLT/SHR.

TREAT. 4

CORR.

CORR.

TRIAGE

VERT RM.

VERT RM.

VERT RM.

B.H. TLT.

B.H. EXAM

CLEAN

NOURISH.

109A

CORR.

CHART

112A

TRIAGE

RECEP.

SOILED

UTIL.

ELEVATOR

LOBBY

ELEVATOR

LOBBY

C1E9

OFFICE

E147B CORR.

C1E8 TRANSCRIPTION

OFF.

E144

R.O.I E145

CORR.

C1E8

CHECK-IN

A119

PHARM.

CARE

SVC.

A119A

MEN TLT

E108

FAMILY

TLT

E107

WOMEN

TLT

E106

ST. LNGE.

B144

ST. TLT

B143

OI&T

CLOSET

B144A

PAT. REP.

E108B

DETAILS

CLERK

E108C

CL.

E105

CL.

E104

CL.

E103

CORR

C1A1

WAITING

8' - 6"

8' - 6"

8' - 6"

8' - 0"

8' - 0" 8' - 0" 8' - 0"8' - 0"8' - 0"

LKR.

B144B

N. STN./

PHYS. WK.

E.N.T.

EXAM

H. NURSE

/ NOD

ST. LNGE./

LKR/

CONF.

ISO.

104EXAM

EXAM

EQ. STG.

F.M.S.

ENG.

E137

INFO.

MGT. SVC

E147C

F.M.S.

ENG.

E138 R.O.I

E146

EYE

SCREENING

E147A

8' - 0"

CORR

C1E6

LOBBY

C1E3

VEST.

CORR.

CORR.

ENTR.

VEST.

EXAM

TRAVEL

TELEHEALTH

IMAGING

CASHIER

CASHIER

WINDOWS

PHARMACY

TREAT. 3

PAT.

INTERVIEW.

B133

PAT. TLT.

B130

HALL

CORR.

CORR.

PT-8 PT-8 PT-8 PT-8 PT-8 PT-8

AS701

B

EX

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

AS701

AS701

AS701

AS701

NOT IN

SCOPE OF

WORK

EX

AS701

EXEX

EX

PT-3 PT-3

AS701

INFO.

DESK

C1E35

PT-13

PT-4

PT-4 PT-4 PT-4 PT-4

PT-4 PT-4PT-4

PT-13

PT-4

PT-5 PT-5

PT-5

PT-5

CEILING

BELOW

PT-4

PT-13

PT-13

PT-13

PT-13

PT-13

PT-13

PT-13

PT-4

10' - 0"

10' - 0"

10' - 0" 10' - 0"

PT-4, ON

CEILING

BELOW; REF

PERSPECTIVE

PT-5 PT-5

PT-4

PT-13

PT-13

AS701

PT-3

AS701

AS701 8' - 0"

AS102

9" 9"

1' - 6"

5/8" GYP. BD. ON

1 5/8" MTL STUD @ 16"

O.C. TYP.

5/8" GYP. BD. ON

2 1/2" MTL STUD @ 16"

O.C. TYP.

RECESSED LINEAR

LIGHT FIXTURE -

REF. ELECTRICAL

NOTE: COORDINATE

EXACT DIMENSIONS W/

FIXTURE PURCHASED.

NOTIFY ARCHITECT IF

ADJUSTMENTS ARE

NECESSARY

OPEN

BEYOND

5/8" GYP. BD. ON 3 5/8"

MTL STUD, 16" O.C.

TYP.

EXISTING CEILING

TO REMAIN, PAINT

PT-1

PT-13

PT-1

PT-4

VARIES REF.

CEILING PLAN

EXISTING BEAM

NOTE: COORDINATE

EXACT DIMENSIONS W/

FIXTURE PURCHASED.

NOTIFY ARCHITECT IF

ADJUSTMENTS ARE

NECESSARY

5/8" GYP BD. ON 3

5/8" MTL STUD @ 16"

O.C. TYP.

LIGHT FIXTURE ; REF. ELEC.

5/8" GYP. BD. ON

1 5/8" MTL STUD @ 16"

O.C. TYP.

5/8" GYP. BD. ON

2 1/2" MTL STUD @ 16"

O.C. TYP.

RECESSED LINEAR

LIGHT FIXTURE -

REF. ELECTRICAL

NOTE: COORDINATE

EXACT DIMENSIONS W/

FIXTURE PURCHASED.

NOTIFY ARCHITECT IF

ADJUSTMENTS ARE

NECESSARY

1' - 2" 9"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

AS701

FIRST FLOOR REFLECTED

CEILING PLAN

RENOVATE MAIN LOBBY 589-334

04/03/2018

N

1" = 80'-0"

KEY PLAN FIRST FLOOR

1 1/2" = 1'-0"

DETAIL

1 1/2" = 1'-0"

SOFFIT DETAIL

1 1/2" = 1'-0"

DETAIL

1/8" = 1'-0" B

REFLECTED CEILING PLAN - SECOND

FLOOR

1/8" = 1'-0" A

REFLECTED CEILING PLAN - FIRST

FLOOR

N 4' 8' 16'

1/8" = 1'-0"

0'

N 4' 8' 16'

1/8" = 1'-0"

0'

PLAN NOTES - FLOOR PLAN

# DESCRIPTION

1 NEW EJ COVERS & RUBBER GASKET - REF. SPECS & SHEET AI101 FOR DETAILS

2 REINSTALL EXISTING DESK ON TOP OF NEW FLOORING

3 MATCH EXISTING WALL AND BASE FINISH

4 OPEN TO ABOVE

5 USE SELF LEVELING CONCRETE TO MAKE WALK-OFF TILE LEVEL W/ ADJACENT

FINISHES

6 PAINT SOFFIT AS CONTINUES IN ENTRY VESTIBULE

7 NEW TOILET PARTITIONS - REF. SPECS

1 1/2" = 1'-0"

SOFFIT DETAIL

1/4" = 1'-0"

SECTION

1 1/2" = 1'-0"

BEAM DETAIL

1 1/2" = 1'-0"

SOFFIT DETAIL

PT-5

PT-4

PT-4 PT-5

PT-4

PT-5

PT-4

PT-4

PT-5

PT-5

PT-4

PT-4

PT-5

PT-5

PT-4

PT-4

PT-4

PT-4

PT-4

PT-4

PT-1

PT-4

PT-4

PT-4

PT-4

PT-5

PT-5

PT-1

PT-5

PT-4

PT-

PT-4 (ABOVE TILE)

PT-4

PT-5

PT- 5

PT-4

PT- 4

PT- 4

PT- 4

PT- 4

PT-5

PT-4

PT-4

PT- 5

PT-5

KEEP

KEEP

KEEP

GYP/PT-13

GYP/PT-13

GYP/PT-13

PT-4

PT-5

PT-1

PT-5

PT-4

PT-4

PT-4

PT-5

PT-5

PT-5

PT-4

PT-4

PT-4

PT-4

PT-4

PT-5

STOP PAINT AT

ATRIUM SIDE OF

GLASS

PT-5

PT-5

PT-4

PT-4

PT-13

PT-13

PT-4 PT-4

P T -4

P T-4

P T-4

PT-4

PT-5

PT-5

PT-4

PT-4

PT-4

PT-4

PT-4PT-4

WORK

E102G

HBA

E102F

ROI

LEGAL

E102E

HBA

E102D

HBA

E102C

HBA

E102B

PRE-REG

E102A

KIOSK

E101

PERSONAL

EFFECTS

E102K

SUPPLY

E102J

ADMISSIONS

LEAD

E102I

ADMISSIONS

SUPERVISOR

E102H

8' - 0" 8' - 0" 8' - 0"

8' - 0"

8' - 0"

9' - 1"

HALL

E102

EX

7' - 11"7' - 11"

EX

IN

F

IL

L

C E

IL

IN

G

CHECK-IN

A119

PHARM.

CARE

SVC.

A119A

MEN TLT

E108

FAMILY

TLT

E107

WOMEN

TLT

E106

PAT. REP.

E108B

DETAILS

CLERK

E108C

CL.

E105

CL.

E104

CL.

E103

CORR

C1A1

WAITING

8' - 6"

8' - 6"

8' - 6"

8' - 0"

8' - 0" 8' - 0" 8' - 0"8' - 0"8' - 0"8' - 0"

CORR

C1E6

LOBBY

C1E3

ENTR.

VEST.

EXAM

CORR.

PT- 8 PT- 8 PT- 8 PT- 8 PT- 8 PT- 8

EX

NOT IN

SCOPE OF

WORK

EX

EXEX

PT- 3

PT- 3

INFO.

DESK

C1E35

PT- 4

PT- 4

PT- 4 PT- 4 PT- 4

PT- 4 PT- 4PT- 4

PT- 13

PT- 4

PT- 5

PT- 5 PT- 5

PT- 5

PT- 4, ON

CEILING

BELOW; REF

PERSPECTIVE

PT- 4

PT- 4

PT- 4

PT- 13

PT- 13

PT- 13

PT- 13

PT- 13

PT- 13

PT- 13

PT- 4

10' - 0"

10' - 0" 10' - 0"

10' - 0"

10 3

PT- 3

PT- 13PT- 13PT- 13PT- 13

PT- 13

PT- 4

PT- 4 PT- 4 PT- 4 PT- 4

P T

P T

5 KEY EXAMPLE: VIEW 5 CAMERA LOCATION AND VIEW

THIS

LOCATION

ON 2ND

FLOOR

WALKWAY

PT - 1

PT - 1

PT - 5

PT - 5

PT - 5

PT - 4

PT - 5

PT - 4 PT - 4

PT - 4

PT - 4

PT - 4

PT - 4

PT - 4

PT - 4

GYP PT - 13 PT- 5

PT- 4

PT- 4

P T

PT- 4

PT- 4

PT- 5

PT- 5

PT- 4PT- 4

PT- 4

PT- 4

PT- 4

PT- 4

PT- 4

PT- 4

PT- 5

PT- 4

PT- 5

PT- 5

PT- 5

PT- 4

PT- 4

PT- 4

PT- 5

PT- 4

PT- 4

PT- 5

PT- 5

PT- 5

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

AS702

FIRST FLOOR CEILING PAINT

REFERENCE

RENOVATE MAIN LOBBY 589-334

04/03/2018

N.T.S

VIEW 1- WAITING 142 - SOUTHWEST

N.T.S

VIEW 2

N.T.S

VIEW 3

N.T.S

VIEW 4

N.T.S

VIEW 5

N.T.S

VIEW 9

N.T.S

VIEW 10

1/8" = 1'-0" A

REFLECTED CEILING PLAN - PHOTO

KEY

N 4' 8' 16'

1/8" = 1'-0"

0'

N.T.S

VIEW 6 FROM 2ND FLOOR WALKWAY

N.T.S

VIEW 7 FROM 2ND FLOOR WALKWAY

N.T.S

VIEW 8