36C25518R0539-0001011.pdf

PDF 3 MB Posted

Attached to
589-334, CO EXPAND PHARMACY AND LOBBY
Solicitation number
36C25518R0539
Issued by

About this file

36C25518R0539 0001 Drawings Renovate Lobby-Vol 1.pdf

View the file

Other files

File Type Posted
36C25518C0223-000.docx DOCX document
36C25518R0539-0005000.docx DOCX document
36C25518R0539-0004001.pdf PDF
36C25518R0539-0004000.docx DOCX document
36C25518R0539-0003001.pdf PDF
36C25518R0539-0003000.docx DOCX document
36C25518R0539-0002002.pdf PDF
36C25518R0539-0002000.docx DOCX document
36C25518R0539-0002001.docx DOCX document
36C25518R0539-0001003.pdf PDF
36C25518R0539-0001008.pdf PDF
36C25518R0539-0001009.pdf PDF
36C25518R0539-0001001.pdf PDF
36C25518R0539-0001005.pdf PDF
36C25518R0539-0001004.pdf PDF
36C25518R0539-0001014.pdf PDF
36C25518R0539-0001013.pdf PDF
36C25518R0539-0001002.pdf PDF
36C25518R0539-0001010.pdf PDF
36C25518R0539-0001015.pdf PDF
36C25518R0539-0001012.pdf PDF
36C25518R0539-0001007.pdf PDF
36C25518R0539-0001006.pdf PDF
36C25518R0539-0001016.pdf PDF
36C25518R0539-0001000.docx DOCX document
36C25518R0539-008.pdf PDF
36C25518R0539-005.pdf PDF
36C25518R0539-001.docx DOCX document
36C25518R0539-003.pdf PDF
36C25518R0539-007.pdf PDF
36C25518R0539-006.pdf PDF
36C25518R0539-004.pdf PDF
36C25518R0539-002.pdf PDF
36C25518R0539-000.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

PROJ(D)

PLBG

PLYWD

PREFIN

RAD(R)

RESIL

REINF

REQ'D

SECT

SHWR

SPECS

REFRIG

galvanizedGALVBMRK benchmark concrete mansonry unit ceilingCLG

CLR

CMU

COL

CLO

clear/clearance column closet

CAB

CJ

CC

CB

BW

CL

BOC

BRZ

BRK

BO

BRG

BUR

BTM

BS

built-up roof center to center chalkboard bottom of wall center line control joint/ construction joint cabinet back of curb both sides bottom of bronze brick bearing bottom foundation floor drain fire extinguisher fire extinguisher cabinet

FE

FEC

FDN

FD

east each equipment exposed each way existing electrical exterior insulation finish system elevation/elevator expansion joint existing grade electrical contractor exterior ethylene propylene diene terpolymer

ELEV

EQUIP

EW

EPDM

EXP

EXIST

EXT

E

EA

EC

EG

EIFS

EJ

ELEC

insulation interior inside diameter

INSUL

IN(")

INT

ID

inch grab bar general contractor gypsum glass/glazing hollow metal high pressure decorative laminate horizontal hardware hardwood hose bib hot water heating, ventilating & air conditioning

HDWR

HM

HORZ

HT

HPDL

HVAC

HW

height

GB

GL

GRD

GYP

GC

HDWD

HB

grade

PART

PLAS

OVHD

partition plaster overhead

SRT

SS

SQ

miscellaneous masonry opening not in contract not applicable outside diameter numberNO(#)

NTS

OC

OA

NOM

OFF

OPNG

OD

on center overall nominal not to scale office opening

MISC

N

MO

MULL

MTL

NIC

NA

north mullion metal

SHT

SF

SB

SND

SIM

S

RM

ROW

RO

SAT

SAN

architect/ architectural

AB anchor bolt

APPROX

BLDG

BD

ARCH

BM

BLK

ADJ

AFF

AC

ACCU

ALUM

ANOD

ALT

approximate block/blocking at board beam building air cooled condensing unit above finish floor adjustable alternate anodized acoustical aluminum

A/C air conditioning plus or minus constructionCONST course ceramic tile continuous carpet corridor diameter door down ditto dimension double drinking fountain detail drawing downspout

DIA

DR

DS

DN

DO

DIM

DTL

DWG

CRS

CT

CONT

CORR

CPT

DBL

DF

conference concrete

CONF

CONC

finishFIN fluorescent flow line folding field verify furnace footing fire retardant foot scraper fiberglass reinforced plastic

FV

FT(')

FURR

FURN

FTG

G

GA

foot furring gas gauge

FRP

FLR

FLDG

FL

FRT

FS

FLUOR

floor finish grade finish floor

FG

FF

joistJST low volume change masonryMAS

MANUF

MATL

MAX

MECH

MEMB

MH

MIN

MIRR

manufacturer material mechanical membrane maximum minimum manhole mirror

LDR

LF

LAV

LAM

LVC

LOCN

lineal feet ladder lavatory laminate location

REF

R

RAG

RD

PT

PR

QT

PTD

JT

JAN janitor joint

PL

under cabinet lightrequired physical therapy respiratory therapy surgical intensive care unit studded rubber tile stainless steel square specifications

YD

suspended acoustical tile similar sanitary napkin dispenser section shower sheet square feet splash block resilient south sanitary right of way rough opening room

WD

WNDW

WH

WNSCT

WC

WT

WWF

WP

VCT

VWC

VEST

VERT

W

W/

W/O yard waterproofing, waterproof welded wire fabric water heater water closet window wood wainscot weight vinyl composition tile vinyl wall covering vertical vestibule west with with out

RT

SICU

central sterile long term care intensive care unit occupational therapy magnetic resonance imaging post anesthetic care unit medical intensive care unit labor-delivery-recovery-post partum operating room

FOR MEDICAL

emergency room computed tomography

FACILITIES ONLY

STORplumbing project/(projected) refer/reference roof drain radius return air grille reinforcing refrigerator riser pressure treated painted quarry tile plywood prefinished pair

TLT

TV

TW

TOC

TPH

TO

TYP

UCL

T&B

T

SUSP

STRUCT

TEL

TB

T&G plate/plastic/ property line STL

STD

storage toilet paper holder top of curb toilet television top of typical top of wall tongue & groove top & bottom structure/structural tread telephone tackboard suspended

ICU

OR

LDRP

MRI

MICU

LTC

PT

PACU

OT

CS

CT

ER

steel standard

DRAWING SYMBOLS

95.00

TOC

98.5

TOC

98.5 E

B

NEW ELEVATION

EXISTING ELEVATION

EXISTING CONTOUR

NEW CONTOUR

TEST BORING (SITE PLANS ONLY)

EXISTING ELEVATION

EXISTING ELEVATION

PROPERTY LINE

/1 A101

/1 A101

MATCHLINE

SHT. REFERENCE

ELEVATION DATUM

(SECTIONS, ELEVATIONS ONLY)

BUILDING SECTION

WALL SECTION

DETAIL DRAWING

A3.1

BUILDING ELEVATION

A6.1 INTERIOR ELEVATION

A100

WINDOW ID TAG

DOOR NUMBER

ROOM

NAME

ROOM NAME & NUMBER

PARTITION SYMBOL

1 REVISION TAG

COLUMN LINE GRID

ME100E EQUIPMENT NUMBER

? SITE PLAN NOTES

DEMOLITION PLAN NOTES

PRECAST CONCRETE

WALL PANEL TAG

XXX

A101

A-4 ALTERNATE TAG

PT-XX PAINT COLOR TAG

# PLAN NOTES

X

X.X

X

X.X

CUT STONE

STEEL

PLYWOOD

FINISH WOOD

CONT WD FRAMING

WOOD BLOCKING

MATERIAL SYMBOLS

LVC FILL

GRANULAR FILL

CONCRETE MASONRY

FACE BRICK

CONCRETE

EARTH

EXISTING

CONSTRUCTION

ASPHALT

GLASS

RIGID OR TAPERED

INSULATION, EIFS

BATT INSULATION

GYPSUM BOARD

BID ITEMS

REFERENCE SECTION 01 00 00 GENERAL REQUIREMENTS ITEM 1.3 STATEMENT OF BID ITEMS.

STATEMENT OF BID ITEM(S)

THIS SINGLE SOLICITATION CONSISTS OF TWO PROJECTS WITH THE INTENT TO AWARD TO ONE CONTRACTOR DUE TO THE PHASING REQUIREMENTS OF THESE PROJECTS. BID ITEM #1, GROUPED AS BID ITEM #1A AND BID ITEM #1B, CONSISTS OF BOTH PROJECTS IN THEIR ENTIRETY. BID ITEM #2 CONSISTS OF ONE PROJECT (EXPAND PHARMACY AND LOBBY) IN ITS ENTIRETY; THE RENOVATE MAIN LOBBY HAS BEEN REMOVED FROM BID ITEM #2. BID ITEM #2A CONSISTS OF THE DEDUCT #1 OF THE EXPAND PHARMACY AND LOBBY PROJECT. BID ITEM #2B CONSISTS OF THE DEDUCT #2 OF THE EXPAND PHARMACY AND LOBBY PROJECT. THE BID PROPOSALS SHOULD BE PACKAGED IN A MANNER THAT WOULD ALLOW THE COMPARISON OF EACH BID ITEM (PROJECT) TO THE INDEPENDENT

GOVERNMENT COST ESTIMATE (IGCE). EACH BID ITEM IN BID ITEM 1 REPRESENTS A SEPARATE PROJECT WITH A UNIQUE OBLIGATION NUMBER. AS SUCH, THE CONTRACTOR SHALL BE REQUIRED TO ADMINISTER EACH CONTRACT INDIVIDUALLY REGARDING PAYMENT AND PERFORMANCE BONDS, PAYMENT REQUESTS, PROGRESS SCHEDULES, SUBMITTALS, DAILY LOGS, ETC.

A. BID ITEM #1: RENOVATE MAIN LOBBY and EXPAND PHARMACY AND LOBBY:

BID ITEM #1A: RENOVATE MAIN LOBBY: includes all scope communicated in the drawings and specifications which includes the complete renovation of the main lobby. The scope of work involves selective interior demolition.

BID ITEM #1B: EXPAND PHARMACY AND LOBBY: includes all scope communicated in the drawings and specifications which includes the complete renovation of the first floor transcription office, travel, telehealth imaging, pharmacy, cashier and surrounding areas, and second floor existing bronze clinic and new pharmacy and eye clinic additions. The scope of work involves hazardous materials abatement and selective interior demolition.

B.BID ITEM #2: EXPAND PHARMACY AND LOBBY: includes all scope communicated in the drawings and specifications which includes the complete renovation of the first floor transcription office, travel, telehealth imaging, pharmacy, cashier and surrounding areas, and second floor existing bronze clinic and new pharmacy and eye clinic additions. The scope of work involves hazardous materials abatement and selective interior demolition.

C.BID ITEM #2A: EXPAND PHARMACY AND LOBBY – BID DEDUCT #1: all work in Bid Item #2 with the following exceptions:

a. In lieu of three new exam rooms, F265-F267, provide a storage room. Refer to the drawings and specifications for additional information.

D. BID ITEM #2B: EXPAND PHARMACY AND LOBBY – BID DEDUCT #2: all work in Bid Item #2A with the following exceptions:

a.In lieu of the new pharmacy addition complete with consult rooms, swamp, office, pharmacy work and vault, provide only one new storage room and electrical room with a corridor accessing the north exit door. The new construction shall include the thickened slab for a future vault. All civil work related to this area shall remain in the scope of work.

APPROVAL SIGNATURES

MEDICAL CENTER DIRECTOR

ASSOCIATE DIRECTOR

ASSISTANT DIRECTOR

CHIEF OF STAFF

ASSOCIATE DIRECTOR OF PATIENT SERVICES

CHIEF OF FACILITIES MANAGEMENT

CHIEF OF HEALTH ADMINISTRATION SERVICE

INFECTION CONTROL PRACTITIONER

SAFETY OFFICER

DATE

DATE

DATE

DATE

DATE

DATE

DATE

DATE

DATE

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

GI101

TITLE SHEET

RENOVATE MAIN LOBBY

HARRY S. TRUMAN MEMORIAL VETERANS' HOSPITAL

RENOVATE MAIN LOBBY

COLUMBIA, MO

100% CONSTRUCTION DOCUMENTS

589-334

589-334

04/03/2018

SHEET INDEX

GENERAL

GI101 TITLE SHEET

GI102 ACCESSIBILITY

GI103 FIRST FLOOR LIFE SAFETY PLAN

GI104 FIRST FLOOR PHASING PLAN - PH 1

GI105 FIRST FLOOR PHASING PLAN - PH 2

ARCHITECTURAL

AD101 FIRST FLOOR PLAN - DEMOLITION

AD102 FIRST FLOOR REFLECTED CEILING PLAN - DEMOLITION

AS101 FIRST FLOOR PLAN

AS102 FIRST FLOOR PLAN - DIMENSIONS

AS701 FIRST FLOOR REFLECTED CEILING PLAN

AS702 FIRST FLOOR CEILING PAINT REFERENCE

ARCHITECTURAL INTERIORS

AI101 FIRST FLOOR FINISH PLAN

AI201 FIRST FLOOR EQUIPMENT PLAN

AI301 FIRST FLOOR WALL PROTECTION & SIGNAGE PLAN

AI401 INTERIOR ELEVATIONS

AI501 MILLWORK SECTION DETAILS

PLUMBING

FP101 FIRE PROTECTION PLAN FIRST FLOOR

PP001 PLUMBING COVER SHEET

PD101 BASEMENT AND FIRST FLOOR PLUMBING DEMOLITION PLANS

PL101 BASEMENT AND FIRST FLOOR PLUMBING PLANS

PL301 PLUMBING RISER DIAGRAMS

PL501 PLUMBING SCHEDULES

MECHANICAL

MM001 MECHNICAL COVER SHEET

MM002 MECHANICAL COVER SHEET

MD101 HVAC DEMOLITION PLAN - FIRST FLOOR

MH101 HVAC FLOOR PLANS

M-501 MECHNICAL DETAILS

M-502 MECHNICAL DETAILS

M-511 MECHANICAL CONTROL DIAGRAMS

M-601 MECHANICAL SHEDULES

ELECTRICAL

E-001 ELECTRICAL LEAD SHEET

ED101 ELECTRICAL FIRST FLOOR DEMO PLAN

EL101 ELECTRICAL FIRST FLOOR LIGHTING PLAN

EL501 ELECTRICAL LIGHTING DETAILS

EP101 ELECTRICAL FIRST FLOOR POWER PLAN

EP501 ELECTRICAL POWER DETAILS

EY101 ELECTRICAL FIRST FLOOR SYSTEMS PLAN

EY501 ELECTRICAL SYSTEMS DETAILS

CL

CL

3'-0" 4'-0" 3'-0"

3'-6" 3'-6"

6"

M

IN

HANDRAILS

H.C. LAVATORYH.C. URINAL

H.C. FLOOR MTD. TOILET

LAV FLOOR SPACE

ACCESSIBLE

SINGLE TOILET

WHEELCHAIR MANEUVERING

MANEUVERING CLEARANCES AT DOORS

BATHROOM FIXTURES & ACCESSORIES

LATCH SIDE APPROACH LATCH SIDE APPROACH HINGE SIDE APPROACH

HINGE SIDE APPROACH FRONT APPROACH FRONT APPROACH

GENERAL REACH DIMENSIONS

LAVATORY DIMENSIONS

MOUNTING HEIGHT DIMENSIONS

90 TURNS 180 TURN

1 1/2 " CLEAR

16"-18" Lavatory

60" min

1.25"-2" DIA.

IF CIRCULAR

NO SCALE

Pull Side

Push Side

Push Side

Push Side Pull Side m in

24"min.

X

Y

X m in

Y m in

Y

54" min.

m in

X

24" min.

X

Y m in

NOTE: y=48" minimum if door has both a latch and closer.

36" min m a x

7-9"

Sanitary napkin disposal

Toilet paper dispenser

24"-42"6" max

12" max m in m in

1'-7" min

8" min6" max

Clearance profile

Insulate drain & supply lines m a x

Mirror

Paper towel dispenser

Soap dispenser 3 m in

19" max

48" min

17" min

"12" min

16"-18"

54" min

42" min

NO SCALE

m a x

14"min

"m a x

TO FLUSH CONTROL

NOTE: y = 54" minimum if door has closer

NOTE: y=48" min if door has closer NOTE: x = 36" min if y = 60", x = 42" min if y = 54"

18" minimum 24" preferred

NOTE: x = 12" if door has both a closer and latch.

TELEPHONE

CLOCK

LIGHT SWITCH

"6

M

A X

M

A X

M

A X

(TO HIGHEST

OPERABLE PART)

17" MIN

M

IN

M

IN

M

A X

M

A X

M

IN

6" MAX

17" MIN

M

IN

M

A X

M

A X

M

IN

6" MAX

8" MIN

OCCUPANCY SIGN

LATCH SIDE PREFERRED

THERMOSTAT

OR OTHER

CONTROL

48"

M

IN

Z

48"

Y

X 30" 24"

M

A X

30"

10" MAX

21" MAX

M

IN

M

A X

36" MIN

M

IN

M

A X

NOTE: X SHALL BE < 25";

Z SHALL BE > X, WHEN X < 20",

THEN Y SHALL BE 48" MAX

WHEN X IS 20"-25",

THEN Y SHALL BE 44" MAX.

INSULATE

EXPOSED PIPES

NO SCALE

NO SCALE

NO SCALE

-1 m in

GRAB BARS

1 1/2 " CLEAR1.25"-2" DIA.

IF CIRCULAR

IF NON-CIRCULAR

PERIMETER MUST

BE 4"-6.25" AND

DIAMETER MUST

NOT EXCEED 2.25"

IF NON-CIRCULAR

PERIMETER MUST

BE 4"-6.25" AND

DIAMETER MUST

NOT EXCEED 2.25"

.5 m in m in

18" min. grab bar per

ANSI A117.1-2009 39"-41"

/4

/2

BEVELED FLOORING TRANSITIONS

/4 m a x

/2 m a x

BEVELED FLOORING TRANSITIONS

TURNING CLEAR

5'-0" 2'-6"

TOP AND SIDES

MUST BE

UNOBSTRUCTED. UP

TO 20% OF BOTTOM

MAY BE

OBSTRUCTED FOR

SUPPORTS.

M

IN

M

A X

NO SCALE

NO SCALE NO SCALE

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

GI102

ACCESSIBILITY

RENOVATE MAIN LOBBY 589-334

04/03/2018

FECFEC

FEC

F E

C

FEC

FEC

FEC

FEC

F E

C

F E

C

F E

C

448/5

34"

34.5"

97+36

448/5

23.4"

105.5"

3 3 3 3

PRE-REGHBAHBAHBAROI LEGAL

WORK

ADMISSIONS

SUPERVISOR

ADMISSIONS

LEAD

SUPPLY

KIOSK

HBA

HALL

2WAITING

PERSONAL

EFFECTS

PAT. REP.

MEN TLT

ELEVATOR

LOBBY

TRANSCRIPTION

OFF.

ST. LNGE./

LKR/ CONF.

SOILED

UTIL.

H. NURSE /

NOD

E.N.T.

EXAM

ISO.

EXAM

EXAM

CORR.

TRIAGE

RECEP.

TRIAGE

CORR.

PT.

TLT/SHR.

TREAT. 4

N. STN./

PHYS. WK.

B.H. EXAM

2 CLEAN

CHART

NOURISH.

VERT RM. 3

VERT RM. 2

VERT RM. 1

EYE

SCREENING

OFFICE

INFO. MGT.

SVC

F.M.S. ENG. R.O.I

R.O.I

CORR.

ELEVATOR

LOBBY

F.M.S. ENG.

EQ. STG.

VEST.

ADMIN.

OFFICE

OFFICE

LKR.

ST. LNGE.

CORR.

DETAILS

CLERK

FAMILY TLT

WOMEN

TLT

CL.CL. CL.

PHARM.

CARE SVC.

2CHECK-IN

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

HOME

TELEHEALTH

N.

ENVIRO.

MGT.

OFFICE

OFFICE

EXAM /

OFFICE

EXAM /

OFFICE

EXAM /

OFFICE

EXAM /

OFFICE

EXAM /

OFFICE

ST. LNGE.

TLT. TLT.

CORR.

CORR.CORR. CORR.

EXAM

SPEC.

PHARMACY

OFFICE

BLDG. MGT.

LKR./

LNGE./ TLT.

BLDG. MGT.

LKR./

LNGE./ TLT.

TLT.

WAITING

CORR.

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

DIETITIAN

PROCS.

EXAM

EXAM

EXAM

GYN. EXAM

TLT.

GYN. EXAM

TLT

CONSULT

RM.

CLEAN

UTIL.

M.P.R. /

CONF.

CLASS

SOILED

UTIL.

TLT.

CORR.

CORR.CORR.

EXAM RM. 5

EXAM

PSY.

EXAM

GYN.

2 TLT.

EXAM

EXAM

CONSULT

RM.

EXAM

EXAM

EXAM

EXAM

EXAM

OFFICE

OFFICE

ST. TLT

N. STN.

CORR.CORR.

CORR.

CORR.

M.A.S.

WAITING

CORR.

BLDG. MGT.

LKR./

LNGE./ TLT.

BLDG. MGT.

LKR./

LNGE./ TLT.

CONSULT

RM.

CONSULT

RM.

CONSULT

RM.

CONSULT

RM.

ST. TLT.

M.A.S.

N. STN.

448/5

15.6"

65"

EXAM

EXAM

EXAM

ENTR.

VEST.

OI&T

CLOSET

TLT

SOILED

UTIL.

CLEAN

UTIL.

PROVIDER

WK. RM.

PHARMACY

TRAVEL

TELEHEALTH

IMAGING

1 CASHIER

F.M.S. ENG.

SIGNAL

CASHIER

WINDOWS

STAIR #11

ELEV.

#10

ELEV.

#9

ELEV.

#11

SMOKE COMP 1-1

12, 190 SF

SMOKE COMP 1-2

13, 703 SF

SMOKE COMP 1-1

12, 190 SF

SMOKE COMP 1-3

5, 762 SF

TRASH

EXAM

ELEC./TELE./MECH.

F.M.S. ENG.

DECONTAMINATION

TREAT. 1

CORR.

TREAT. 2

RESUS /

BARIATRIC

TREAT. 3

STAIR #10

SMOKE COMP 1-3

5, 762 SF

SMOKE COMP 1-4

5, 705 SF

448/5

11.8"

57"

PAT.

INTERVIEW.

PAT. TLT.

RECEP. /

SCHED.

ST. WK/

PAT.

INTERVIEW

448/5

15.2"

34.5"

EXIT

TD = 109'-4"

STAIR #10 EXITS

THIS LEVEL

TD = 194'

TD = 155'-2"

EXIT

FIRE SHUTTERS

@ WINDOWS

EXIT

TD = 159'

INFO. DESK

WEST

CONCOURSE

VALET

W.C. STOR.

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY

NFPA 2015

(NEW HC)

NFPA 2015

(EXIST. HC)

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE WALL (TYPE I)

3 HRNOT

APPLICABLE

3 HR FIRE

3 HR

NOT

APPLICABLE

BUILDING SEPARATION:

FIRE WALL (TYPE II)

2 HR NOT

APPLICABLE

90 MIN FIRE

90 MIN

NOT

APPLICABLE

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR 90 MIN NFPA 8.2.3.2.3.1

(1)

FIRE

90 MIN

NFPA 6.1.14

NFPA 8.2.3.1.2

NFPA 8.2.3.2.4.1

NFPA 6.1.14

NFPA 8.2.3.1.2

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR 90 MIN NFPA 8.2.3.2.3.1

(1)

FIRE

90 MIN

NFPA 6.1.14

NFPA 8.2.3.1.2

NFPA 8.2.3.2.4.1

NFPA 6.1.14

NFPA 8.2.3.1.2

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)

NFPA 19.3.1.1

NFPA 8.6.5

NFPA 18.3.1

NFPA 8.2.5.4

NFPA 8.3.4 NOT

ALLOWED

1 HR

2 HR

60 MIN

90 MIN

1 HR

2 HR

EXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

NFPA 8.2.3.2.3.1 NFPA 18.2.2.7

NFPA 7.2.6

NOT

ALLOWED

NFPA 1005.3.4.1

NFPA 1021.5

NFPA 19.2.2.7

NFPA 7.2.6

60 MIN

90 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

NFPA 8.4.1.2 SEE

NOTE B

NFPA 8.4.1.2

SUBDIVIDING SPACES

SMOKE BARRIER (1-2 OCCUPANCY)

20 MINNFPA 18.3.7.1

NFPA 18.3.7.3

SMOKE

90 MIN

SEE NOTE [A]

NFPA 8.3.5.1

NFPA 19.3.7.1

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR NFPA 19.2.5 SEE

NOTE [B]

NR

SELF OR AUTO

CLOSING

NFPA 18.2.5

EXIT ACCESS CORRIDORS (1-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NRNFPA 18.2.5 SEE

NOTE [D]

NFPA 19.3.6.2

EXIT ACCESS CORRIDORS (I-1 OR I-2)

FIRE PARTITION (EXIST CONDITION)

(NON-SPRINKLERED)

20 MIN FIRE (I-1)

SMOKE (I-2)

NFPA 19.3.6.21/2 HR NFPA 18.3.6.2

10/1

2"

34"

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

1:50

FIRE EXTINGUISHER AND CABINET

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FEC

FACP

FSA

FAA

100'

(50)

STARTING

LOCATION

EXITING #

TRAVEL

DISTANCE

TRAVEL PATH

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF SMOKE BARRIERS

WHERE HVAC SYSTEMS ARE FULLY DUCTED (18.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL HAVE DAMPERS (NFPA

8.2.4.4.3)

[C] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE PROTECTED

ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 18.3.6.4)

NOTES

SYMBOLS

EXISTING TO

REMAIN

REMODEL

AREA

CODE INFORMATION

PROJECT INFORMATION:

1. CONSTRUCTION PURPOSE: RENOVATION

2. REASON FOR SUBMITTAL: RENOVATION

3. I CERTIFY THAT TO THE BEST OF OUR KNOWLEDGE THE

SUBMITTED PLANS FOR THE ABOVE-REFERENCED

PROJECT

COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING.

NOTE: WHERE THE NFPA & ICC CODES ARE NOT

IDENTICAL, THE DESIGN COMPLIES W/ NFPA AS PER VA

REQUIREMENTS:

2015 INTERNATIONAL BUILDING CODE (IBC)

2015 INTERNATIONAL MECHANICAL CODE (IMC)

2015 INTERNATIONAL PLUMBING CODE (IPC)

2014 NATIONAL ELECTRICAL CODE (NFPA-70)

2015 LIFE SAFETY CODE (NFPA-101)

ABA ACCESSIBILITY STANDARDS

4. LOCATION OF ANY ANTICIPATED FUTURE ADDITIONS:

NONE

5. OWNER:

HARRY S. TRUMAN MEMORIAL VETERANS HOSPITAL

800 HOSPITAL DR

COLUMBIA, MO 65201

PH (573) 814-6000

6. DATE DEVELOPED: SEE DATE ON TITLE BLOCK

7. DESIGN TEAM:

ARCHITECT:

M+HFG, LLC

142 N. MOSLEY ST., SUITE 300

WICHITA, KS 67202 316-262-2500

CONTACT: MARK CRANE

DESIGN CONSULTANTS:

PROFESSIONAL ENGINEERING CONSULTANTS

303 S. TOPEKA

WICHITA, KS 67202 316-262-2691

CONTACT:

BECKY HESSE (MECHANICAL)

becky.hesse@pec1.com

JOSH WILCOX (ELECTRICAL)

josh.wilcox@pec1.com

8. ARCHITECTS SEAL: SEE STAMP AT BOTTOM

9. FIRE SERVICE: COLUMBIA, MISSOURI FIRE DEPARTMENT

10. INSPECTION: VISN SAFETY OFFICER

11. OCCUPANCY TYPE: MULTILPLE SEPARATED

OCCUPANCIES

OCCUPANCY FOR THIS PROJECT: AMBULATORY HEALTH

CARE

12. CONSTRUCTION TYPE: TYPE II (222) PER NFPA

13. STRUCTURAL CODE REQUIREMENTS

A. ALLOWABLE FLOOR AREA: UNCHANGED

B. ALLOWABLE HEIGHT: UNCHANGED

NO HEIGHT MODIFICATIONS REQUIRED

C. FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS: TYPE II (222)

1. BEARING WALLS:

A. EXTERIOR: 2HR

B. INTERIOR: 2HR

2. NONBEARING WALLS:

A. EXTERIOR: 0HR, 1HR, SEE NFPA 5000

TABLE 7.3.2.1

B. INTERIOR: 0HR

3. COLUMNS: 2HR

4. BEAMS, GIRDERS,

TRUSSES, & ARCHES: 2HR

5. FLOOR/CEILING ASSEMBLIES: 2HR

6. ROOF/ CEILING ASSEMBLIES: 1HR

OTHER REQUIREMENTS:

1. NFPA 101 18.3.2.1:

1 HR OCCUPANCY SEPARATION REQUIRED AT STORAGE ROOMS

OVER 100 SF

(NEW HEALTH CARE OCCUPANCY)

14. ACTIVE FIRE SAFETY SYSTEMS

* NOTE:

ALL AREAS OF THIS PROJECT WILL BE FULLY SPRINKLERED.

SPRINKLER SYSTEM SHALL COMPLY WITH NFPA

13 IN ALL AREAS

(a) SMOKE DETECTORS THROUGHOUT

(b) GENERATOR POWERED EMERGENCY LIGHTING

(c) GERERATOR POWERED EXIT LIGHTING

(d) PORTABLE EXTINGUISHERS

(e) AUTOMATIC AIR-HANDLING SHUT-DOWN

(f) FIRE ALARM SYSTEM

15. WATER SUPPLY: CITY OF COLUMBIA

16. SEWAGE TREATMENT: CITY OF COLUMBIA

17. HANDICAP PROVISIONS:

ACCESSIBLE ROUTE, TOILETS, LAVATORIES, SIGNAGE AND

ELSEWHERE AS REQUIRED BY ABAAS AND VA

ACCESSIBILITY

N

3/32" = 1'-0" A

FIRST FLOOR LIFE SAFETY PLAN

0' 4'

3/32" = 1'

8' 16'

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

GI103

FIRST FLOOR LIFE SAFETY PLAN

RENOVATE MAIN LOBBY 589-334

04/03/2018

N

1" = 80'-0"

KEY PLAN FIRST FLOOR

EXISTING TO

REMAIN

REMODEL

AREA

PHASE 1

PHASING LEGEND

PHASE 2

NIGHT & WEEKEND

WORK - COORDINATE

WITH COR; PROVIDE

CONSTRUCTION

BARRIER FOR AREA

OF WORK BEING

DONE

CONSTRUCTION

BOUNDARY - INSTAL 1

HR WALL TO DECK AS

REQ'D

DEMO BOUNDARY

LINE OF

CEILING

ABOVE

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NIGHT & WEEKEND

WORK -

COORDINATE TIME

W/ COR

GI104

CONSTRUCTION ENTRY PHASE

MAINTAIN 4' - 0" MIN

FOR STAFF TO

ACCESS ALL ROOMS

DURING

CONSTRUCTION

4' - 1"

REF. SECTION 1/GI104 FOR

PORTIONS OF 1 HR. CONSTR.

BOUNDARY OPEN TO ABOVE

LINE OF

CEILING

ABOVE

CONSTRUCTION ENTRY PHASE

4'-0" CLEAR MIN.

REF. GI105 FOR

MILLWORK

PHASING IN

HBA E102B

UPPER LEVEL MUST BE ENCLOSED W/ 6 MIL MIN.

CLEAR PLASTIC SHEETING OR 1HR CONSTRUCTION

BARRIER TO DECK WHILE WORK IS OCCURING.

CONTRACTOR TO FOLLOW REQUIREMENTS FOR

INFECTION CONTROL AS STATED IN SPECS

1 HR

CONSTRUCTION

WALL

1 HR

CONSTRUCTION

WALL

WAITING

C2E11

WAITING

AREA

OEF/OIF

CASE

MGR.

E108A

PH1

PH1

R.O.I.

E146

TRANSCRIPTION

OFF.

E144

TELEHEALTH

IMAGING

E143

TRAVEL

E140

F.M.S.

ENG.

E138

CORR.

C1F22

ELEVATOR

LOBBY

F.M.S.

ENG.

E137

H. NURSE/

NOD

E.N.T.

EXAM

106PT. TLT.

ISO.

ST. TLT.

SOILED

UTIL.

EXAM

EXAM

RECP.

115TRIAGE

TRIAGE

VERT RM.

VERT RM.

VERT RM.

PT. TLT/

SHR.

EWC

118A

TREAT. 3

TREAT. 4

CORR.

B.H. EXAM

CLEAN

ALCOVE

126A

NOURISH..

109A

CHART

112A

CORR.

CORR.

N. STN./

PHYS. WK.

CORR.

JAN.

OFFICE

B137

LKR.

B144B

ST. TLT.

B143

ST. LNGE.

B144

MED.

ADMIN

E108

F. TLT.

E107

M. TLT.

E106

CORR.

CORR.

C1E14

CORR.

C1E7

CASHIER

WINDOWS

C1E2

MED.

ADMIN.

E102C

MED.

ADMIN.

E102D

MED.

ADMIN.

E102E

MED.

ADMIN.

E102A

MED.

ADMIN.

E102B

MED.

ADMIN.

E102

MED.

ADMIN.

E102G

MED.

ADMIN.

E102F

CORR.

C1E6

LOBBY

C1E3

WAITING

AREA

ALCOVE

113A

ALCOVE

120A

VEST.

MED.

ADMIN.

E102I

MED.

ADMIN.

E102H

PAT. TLT.

B130

PAT.

INTERVIEW

B133

OFFICE

B138

CL.

E105

CL.

E104

CL.

E103

OI&T

CLOSET

B144A

CORR.

C1A1

ADMIN.

B134

CORR

C1E8

CHECK-IN

A119

PAT. REP.

E108B

OFFICE

E147B

ST. LNGE./

LKR/

CONF.

EQ. STG.

144 INFO.

MGT. SVC

E139

EYE

SCREENING

E147A

R.O.I.

E145

CASHIER

E142

CORR.

ELEVATOR

LOBBY

C1E9

OEF/OIF

CASE

MGR.

E108A

DETAILS

CLERK

E108C

VEST.

PHARM.

CARE

SVC.

A119A

EXAM

A121

INFO

DESK.

C1E35

WHEELCHAIR

STORAGE

E102J

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

GI104

FIRST FLOOR PHASING PLAN -

PH 1

RENOVATE MAIN LOBBY 589-334

04/03/2018

N 4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN FIRST FLOOR

N

1/8" = 1'-0" A

FIRST FLOOR PLAN - PHASE 1 DEMO

1/4" = 1'-0"

PHASING PLAN - SECTION

ROI

LEGAL

E102E

HBA

E102D

HBA

E102C

HBA

E102B

ADMISSIONS

LEAD

E102I

ADMISSIONS

SUPERVISOR

E102H

WORK

E102G

HALL

E102

LOBBY

C1E3

LINE OF

CEILING

ABOVE

CORR.

B116

ADMIN.

B134

OFFICE

B138

OFFICE

B137

JAN

LKR.

B144B

ST. LNGE.

B144

MEN TLT

E108

PAT. REP.

E108B

DETAILS

CLERK

E108C

FAMILY

TLT

E107

CL.

E103

CL.

E104

CL.

E105

TREAT. 4

PT.

TLT/SHR.

CORR.

CORR.

119 TRIAGE

RECEP.

CORR.

112 TRIAGE

SOILED

UTIL.

111CLEAN

VERT RM.

VERT RM.

VERT RM.

B.H. EXAM

B.H. TLT.

CHART

112A

ELEVATOR

LOBBY

ELEVATOR

LOBBY

C1E9

OFFICE

E147B

CORR.

C1E8

TRANSCRIPTION

OFF.

E144

R.O.I E145

VEST.

OI&T

CLOSET

B144A

NOURISH.

109A

CORR.

CORR.

C1E8

PHARM.

CARE

SVC.

A119A

CHECK-IN

A119

N. STN./

PHYS. WK.

EXAM

EXAM

ISO.

E.N.T.

EXAM

H. NURSE

/ NOD

ST. LNGE./

LKR/

CONF.

EYE

SCREENING

E147A

R.O.I E146

INFO.

MGT. SVC

E147C

F.M.S.

ENG.

E138

EQ. STG.

F.M.S.

ENG.

E137

CASHIER

WINDOWS

TRAVEL

TELEHEALTH

IMAGING

CASHIER

PAT.

INTERVIEW.

B133

PAT. TLT.

B130

TREAT. 3

HALL

CORR.

CORR.

CORR.

ST. TLT

B143

CORR.

ENTR.

VEST.

EXAM

INSTALL MILLWORK IN

THIS ROOM AT END OF

PH2. THIS ROOM WILL BE

USED FOR STAFF TO

ACCESS THEIR

WORKSPACE DURING PH2

CONSTRUCTION

MAINTAIN 4' - 0" MIN

FOR STAFF TO

ACCESS ALL ROOMS

DURING

CONSTRUCTION

REF. SECTION 1/GI105 FOR

PORTIONS OF 1 HR. CONSTR.

BOUNDARY OPEN TO ABOVE

GI105

INFO.

DESK

C1E35

LINE OF

CEILING

ABOVE

4'-0" CLEAR MIN.

WAITING

HALL

E102

CORR

C1A1

CORR

C1E6

LOBBY

C1E3

PH2

CONSTRUCTION

ENTRY PHASE 2

PH2

CONSTRUCTION

ENTRY PHASE 2

CONSTRUCT A HARD

CEILING OVER

CONSTRUCTION AREA THAT

IS OPEN TO ABOVE TO

MAINTAIN FULL 1HR

ENCLOSURE

EXISTING TO

REMAIN

REMODEL

AREA

PHASE 1

PHASING LEGEND

PHASE 2

NIGHT & WEEKEND

WORK - COORDINATE

WITH COR; PROVIDE

CONSTRUCTION

BARRIER FOR AREA

OF WORK BEING

DONE

CONSTRUCTION

BOUNDARY - INSTAL 1

HR WALL TO DECK AS

REQ'D

DEMO BOUNDARY

1 HR

CONSTRUCTION

WALL

1 HR

CONSTRUCTION

WALL

WAITING

MEN TLT

E108

WAITING

C2E11

UPPER LEVEL MUST BE ENCLOSED W/ 6 MIL MIN.

CLEAR PLASTIC SHEETING OR 1HR CONSTRUCTION

BARRIER TO DECK WHILE WORK IS OCCURING.

CONTRACTOR TO FOLLOW REQUIREMENTS FOR

INFECTION CONTROL AS STATED IN SPECS

CONSTRUCTION

ENTRY PHASE 2

MED.

ADMIN.

E102A

MED.

ADMIN.

E102B

MED.

ADMIN.

E102C

CORR.

C1E7

M. TLT.

E106

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

GI105

FIRST FLOOR PHASING PLAN -

PH 2

RENOVATE MAIN LOBBY 589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR PLAN - PHASE 2 DEMO

N 4' 8' 16'

1/8" = 1'-0"

0'

N

1" = 80'-0"

KEY PLAN FIRST FLOOR

1/4" = 1'-0"

PHASING PLAN - SECTION

File details come from the government source that posted it.